Elite.Parts chervon right Manufacturers chervon right A chervon right AGILENT / HP chervon right N5221A
About product Datasheet FAQ

AGILENT / HP N5221A

Image of AGILENT / HP N5221A

Description

Agilent N5221A Microwave Network Analyzer | 10 MHz to 13.5 GHz

Part Number

N5221A

Price

Request Quote

Manufacturer

AGILENT / HP

Lead Time

Request Quote

Category

PRODUCTS - N

Datasheet

pdf file

Agilent_N5221A_and_N5222A_PNA_Network_Analyzer_datasheet1-611547587.pdf

2933 KiB

Extracted Text

Agilent 2-Port and 4-Port PNA Network Analyzer N5221A 10 MHz to 13.5 GHz N5222A 10 MHz to 26.5 GHz Data Sheet and Technical Specifications Documentation Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED "AS IS," AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, AGILENT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. AGILENT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD AGILENT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL. DFARS/Restricted Rights Notice If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as “Commercial computer software” as defined in DFAR 252.227-7014 (June 1995), or as a “commercial item” as defined in FAR 2.101(a) or as “Restricted computer software” as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies’ standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. 2 Documentation Warranty ..................................................................................................................................... 2 DFARS/Restricted Rights Notice ....................................................................................................................... 2 Definitions ...................................................................................................................................................... 5 Corrected System Performance .......................................................................................................................... 6 System Dynamic Range and Receiver Dynamic Range ........................................................................... 6 Table 1a. System Dynamic Range and Receiver Dynamic Range, N5221A, Option 200 or 400 ........ 7 Table 1b. System Dynamic Range and Receiver Dynamic Range, N5222A, Option 200 or 400 ........ 7 Table 2. System Dynamic Range at Test Port (dB) .................................................................................. 8 Table 3. Extended Dynamic Range at Direct Receiver Access Input (dB) - Specification ................ 8 Corrected System Performance, All Options ............................................................................................ 9 Table 4a. N5221A and N5222A with 85052B Calibration Kit - Specification .................................... 10 Table 4b. N5221A and N5222A with N4691B 2-Port Electronic Calibration Module ...................... 11 Table 4c. N5221A and N5222A with N4433A 4-Port Electronic Calibration Module ....................... 12 Uncorrected System Performance.................................................................................................................... 13 Table 5a. Error Terms (dB), All Ports, All Options - Specifications .................................................... 13 Table 5b. Error Terms (dB), All Ports, All Options - Typical ............................................................... 13 Test Port Output .................................................................................................................................................. 15 Table 6. Frequency Information, All Options ......................................................................................... 15 Table 7a. Maximum Leveled Power (dBm) - Specification ................................................................... 15 Table 7b. Maximum Leveled Power (dBm) - Typical ............................................................................. 16 Table 8. Power Level Accuracy (dB), All Options .................................................................................. 16 Table 9a. Power Level Linearity (dB), All Options - Specification ...................................................... 16 Table 9b. Power Level Linearity (dB), All Options - Specification ..................................................... 17 Table 10a. Power Sweep Range (dB), All Options - Specification ....................................................... 17 Table 10b. Power Sweep Range (dB), All Options - Typical ................................................................. 17 Table 11. Nominal (Preset) Power (dBm)................................................................................................ 18 Table 12. Power Resolution and Maximum/Minimum Settable Power, All Models and Options .. 18 nd rd Table 13. 2 and 3 Harmonics at Max Specified Power (dBc) All Options - Typical .................... 18 Table 14. Non-Harmonic Spurs at Nominal Power (dBc), All Models and Options - Typical ......... 18 Table 15. Phase Noise (dBc/Hz), All Options - Typical ......................................................................... 19 Test Port Input ..................................................................................................................................................... 20 Table 16. Test Port Noise Floor (dBm) @ 10 Hz IFBW, All Options .................................................... 20 Table 17. Direct Receiver Access Input Noise Floor (dBm) ................................................................. 20 Table 18a. 0.1 dB Receiver Compression at Test Port (dBm)- Typical ............................................... 21 Table 18b. Receiver Compression at Test Power - Specification ......................................................... 21 Table 18c. Receiver Compression at Test Power - Specification ......................................................... 21 Table 19. Trace Noise Magnitude (dB rms) ............................................................................................. 22 Table 20. Trace Noise Phase (deg rms) .................................................................................................... 22 Table 21. Reference Level Magnitude, All Models and Options - Specification ................................ 22 Table 22. Stability, All Options - Typical ................................................................................................. 23 3 Table 23. Damage Input Level ................................................................................................................... 23 Dynamic Accuracy .............................................................................................................................................. 24 Table 24. N5221A and N5222A Dynamic Accuracy ............................................................................... 24 Table 25. Group Delay - Typical ................................................................................................................ 26 General Information ............................................................................................................................................ 27 Table 26. Miscellaneous Information ....................................................................................................... 27 Table 27. Front Panel Information, All Options ..................................................................................... 27 Table 28. Rear Panel Information, All Options....................................................................................... 28 Table 29. Analyzer Dimensions and Weight............................................................................................ 32 Regulatory and Environmental Information .......................................................................................... 32 Measurement Throughput Summary................................................................................................................ 33 Table 30a. Typical Cycle Time (ms) for Measurement Completion, All Models and Options ......... 33 Table 30b. N5221A Typical Cycle Time (ms) for Full-Span Measurement Completion .................. 34 Table 30c. N5222A Typical Cycle Time (ms) for Full-Span Measurement Completion .................. 34 Table 31. Cycle Time vs. IF Bandwidth - Typical ................................................................................... 35 Table 32. Cycle Time vs. Number of Points - Typical ............................................................................ 36 Table 33. Data Transfer Time (ms) - Typical .......................................................................................... 37 Specifications: Front-Panel Jumpers ............................................................................................................... 38 Table 34. Measurement Receiver Inputs (dBm) – Typical .................................................................... 38 Table 35. Reference Receiver Inputs and Reference Source Outputs (dBm) - Typical .................... 39 Table 36. Reference Receiver Inputs and Reference Source Outputs (dBm) - Typical .................... 39 Table 37. Source Outputs (dBm) - Typical .............................................................................................. 40 Table 38. Coupler Inputs (dB) - Typical .................................................................................................. 40 Table 39. Damage Level - Typical.............................................................................................................. 41 Test Set Block Diagrams.................................................................................................................................... 42 N5221A and N5222A Option 200 (2-port base model) ......................................................................... 42 N5221A and N5222A Option 201 .............................................................................................................. 42 N5221A and N5222A Option 217 .............................................................................................................. 43 N5221A and N5222A Option 219 .............................................................................................................. 43 N5221A and N5222A Option 400 (4-port base model) ......................................................................... 44 N5221A and N5222A Option 401 .............................................................................................................. 44 N5221A and N5222A Option 417 .............................................................................................................. 45 N5221A and N5222A Option 419 .............................................................................................................. 45 Receiver Block Diagram ............................................................................................................................. 46 4 This is a complete list of the technical specifications for the N5221A and N5222A PNA Series network analyzers with the following options. See block diagrams for all models and options beginning on page 41. 2-Port Models Option 200 - 2-port base model with standard test set. Option 201 - To base model, adds front-panel jumpers and R1 receiver switch. Option 217 - To base model, adds front-panel jumpers, R1 receiver switch, and source and receiver attenuators (extended power range). Option 219 - To base model, adds front-panel jumpers, R1 receiver switch, source and receiver attenuators (extended power range), and bias-tees. 4-Port Models Option 400 - 4-port base model with standard test set. Option 401 - To base model, adds front-panel jumpers and R1 receiver switch. Option 417 - To base model, adds front-panel jumpers, R1 receiver switch, and source and receiver attenuators (extended power range). Option 419 - To base model, adds front-panel jumpers, R1 receiver switch, source and receiver attenuators (extended power range), and bias-tees. Notes This document provides technical specifications for the 85052B, N4691B and N4433A calibration kits. Please download our free Uncertainty Calculator from http://www.agilent.com/find/na_calculator to generate the curves for your calibration kit and PNA setup. For all tables in this data sheet, the specified performance at the exact frequency of a break is the degraded value of the two specifications at that frequency. Definitions All specifications and characteristics apply over a 25 °C ±5 °C range (unless otherwise stated) and 90 minutes after the instrument has been turned on. Specification (spec.): Warranted performance. Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions. Characteristic (char.): A performance parameter that the product is expected to meet before it leaves the factory, but that is not verified in the field and is not covered by the product warranty. A characteristic includes the same guardbands as a specification. Typical (typ.): Expected performance of an average unit which does not include guardbands. It is not covered by the product warranty. Nominal (nom.): A general, descriptive term that does not imply a level of performance. It is not covered by the product warranty. Calibration: The process of measuring known standards to characterize a network analyzer's systematic (repeatable) errors. Corrected (residual): Indicates performance after error correction (calibration). It is determined by the quality of calibration standards and how well "known" they are, plus system repeatability, stability, and noise. Uncorrected (raw): Indicates instrument performance without error correction. The uncorrected performance affects the stability of a calibration. Standard: When referring to the analyzer, this includes no options unless noted otherwise. 5 Corrected System Performance The specifications in this section apply for measurements made with the N5221A and N5222A PNA network analyzers with the following conditions:  10 Hz IF bandwidth  No averaging applied to data  Isolation calibration with an averaging factor of 8 System Dynamic Range and Receiver Dynamic Range  System Dynamic Range is defined as the specified source maximum output power (spec) minus the noise floor (spec).  Extended Dynamic Range at Direct Access Input is defined as the specified source maximum output power (spec) minus the direct receiver access input noise floor (spec).  Receiver Dynamic Range is defined as the test port compression at 0.1 dB (typical) minus the noise floor (typical). NOTE: The effective dynamic range must take measurement uncertainties and interfering signals into account. This set-up should only be used when the receiver input will never exceed its maximum receiver input. When the analyzer is in segment sweep mode, it can have predefined frequency segments which will output a higher power level when the extended dynamic range is required (i.e. devices with high insertion loss), and reduced power when the maximum receiver input level will occur (i.e. devices with low insertion loss). The extended range is only available in one-path transmission measurements. It may typically be degraded at particular frequencies below 500 MHz due to spurious receiver residuals. 6 Table 1a. System Dynamic Range and Receiver Dynamic Range, N5221A, Option 200 or 400 Description Specification Typical Max 0.1 dB Leveled Test Port Receiver Test Port System Compression Output Noise Floor Dynamic Noise Floor Dynamic at Test Port Power (dBm) Range (dB) (dBm) Range (dB) (dBm) (dBm) (A)-(B) (B) (C)-(D) (D) (C) (A) 10 MHz to 50 MHz 94 12 -82 103 15 -88 50 MHz to 100 MHz 108 13 -95 118 15 -103 100 MHz to 500 MHz 118 13 -105 122 12 -110 500 MHz to 2 GHz 127 13 -114 130 12 -118 2 GHz to 13.5 GHz 127 13 -114 131 12 -119 Table 1b. System Dynamic Range and Receiver Dynamic Range, N5222A, Option 200 or 400 Description Specification Typical Max 0.1 dB Leveled Test Port Receiver Test Port System Compression Output Noise Floor Dynamic Noise Floor Dynamic at Test Port Power (dBm) Range (dB) (dBm) Range (dB) (dBm) (dBm) (A)-(B) (B) (C)-(D) (D) (C) (A) 10 MHz to 50 MHz 94 12 -82 103 15 -88 50 MHz to 100 MHz 108 13 -95 118 15 -103 100 MHz to 500 MHz 118 13 -105 122 12 -110 500 MHz to 2 GHz 127 13 -114 130 12 -118 2 GHz to 13.5 GHz 127 13 -114 131 12 -119 13.5 GHz to 20 GHz 127 13 -114 132 12 -120 20 GHz to 24 GHz 124 13 -111 128 10 -118 24 GHz to 26.5 GHz 114 7 -107 126 10 -116 7 Table 2. System Dynamic Range at Test Port (dB) Description Specification Typical Option 217, Option 217, Option 200, Option 201, Option 200, Option 201, 219, 417, 219, 417, 400 401 400 401 419 419 10 MHz to 50 MHz 94 94 94 108 108 108 50 MHz to 100 MHz 108 108 108 123 123 123 100 MHz to 500 MHz 118 118 118 130 130 130 500 MHz to 2 GHz 127 127 127 138 138 138 2 GHz to 3.2 GHz 127 127 127 139 139 139 3.2 GHz to 10 GHz 127 127 127 141 141 141 10 GHz to 13.5 GHz 127 127 127 141 141 140 13.5 GHz to 16 GHz 127 127 127 140 140 139 16 GHz to 20 GHz 127 127 124 140 140 138 20 GHz to 24 GHz 124 124 121 136 136 134 24 GHz to 26.5 GHz 114 114 111 130 130 128 Table 3. Extended Dynamic Range at Direct Receiver Access Input (dB) - Specification Description Option 201, 401 Option 217, 219, 417. 419 10 MHz to 50 MHz 130 130 50 MHz to 100 MHz 120 120 100 MHz to 500 MHz 130 130 500 MHz to 19 GHz 139 139 19 GHz to 20 GHz 139 136 20 GHz to 24 GHz 136 133 24 GHz to 26.5 GHz 126 123 8 Corrected System Performance, All Options Note: For any Sii reflection measurement: Sjj = 0. For any Sij transmission measurement: Sji = Sij when Sij 1 Sji = 1/Sij when Sij 1 Skk = 0 for all k Applies to the N5221A/2A Option 200, 201, 217, 219, 400, 401, 417 or 419 analyzers, 85131F flexible test port cable set, and a full 2-port calibration. Also applies to the following condition: Environmental temperature 23° ±3 °C, with < 1 °C deviation from calibration temperature 9 Table 4a. N5221A and N5222A with 85052B Calibration Kit - Specification Description Specification (dB) 10 MHz to 50 MHz to 500 MHz 2 GHz to 13.5 GHz 20 GHz to 50 MHz 500 MHz to 2 GHz 13.5 GHz to 20 GHz 26.5 GHz Directivity 48 48 48 44 44 44 Source Match 40 40 40 31 31 31 Load Match 48 48 48 44 44 44 Reflection Tracking ±0.003 ±0.003 ±0.003 ±0.006 ±0.006 ±0.006 Mag ±0.020 ±0.020 ±0.020 ±0.040 ±0.040 ±0.040 Phase (°) Transmission Tracking ±0.034 ±0.017 ±0.017 ±0.091 ±0.104 ±0.119 Mag ±0.225 ±0.110 ±0.110 ±0.602 ±0.688 ±0.788 Phase (°) Transmission Uncertainty, All Options Reflection Uncertainty, All Options 10 Table 4b. N5221A and N5222A with N4691B 2-Port Electronic Calibration Module Description Specification (dB) 10 MHz to 50 MHz to 500 MHz 2 GHz to 13.5 GHz 20 GHz to 50 MHz 500 MHz to 2 GHz 13.5 GHz to 20 GHz 26.5 GHz Directivity 46 46 52 46 46 44 Source Match 41 41 47 42 42 40 Load Match 40 40 46 41 40 38 Reflection Tracking ±0.050 ±0.050 ±0.020 ±0.040 ±0.040 ±0.050 Mag ±0.330 ±0.330 ±0.132 ±0.264 ±0.264 ±0.330 Phase (°) Transmission Tracking ±0.062 ±0.056 ±0.023 ±0.054 ±0.055 ±0.072 Mag ±0.410 ±0.370 ±0.152 ±0.354 ±0.365 ±0.473 Phase (°) Transmission Uncertainty, All Options Reflection Uncertainty, All Options 11 Table 4c. N5221A and N5222A with N4433A 4-Port Electronic Calibration Module Note: Uncertainty curves for the N4433A are created using a 2-port calibration. Multiport uncertainties are not supported at this time. Description Specification (dB) 10 MHz to 50 MHz to 500 MHz 2 GHz to 13.5 GHz to 50 MHz 500 MHz to 2 GHz 13.5 GHz 20 GHz Directivity 50 50 50 45 40 Source Match 42 42 42 37 31 Load Match 40 41 41 35 29 Reflection Tracking ±0.060 ±0.060 ±0.060 ±0.100 ±0.180 Mag Phase (°) ±0.396 ±0.396 ±0.396 ±0.660 ±1.188 Transmission Tracking ±0.068 ±0.064 ±0.064 ±0.115 ±0.210 Mag Phase (°) ±0.447 ±0.421 ±0.421 ±0.761 ±1.387 Transmission Uncertainty, All Options Reflection Uncertainty, All Options 12 Uncorrected System Performance Specifications apply to following conditions: Over environmental temperature of 25 °C ±5 °C, with less than 1°C variation from the calibration temperature. Cable loss not included in Transmission Tracking. Crosstalk measurement conditions: normalized to a thru, measured with shorts on all ports, 10 Hz IF bandwidth, averaging factor of 8, alternate mode, source power set to the specified maximum power. Table 5a. Error Terms (dB), All Ports, All Options - Specifications Source Transmission Reflection Description Directivity Load Match Crosstalk Match Tracking Tracking 10 MHz to 50 MHz 16 11 11 -- -- -- 50 MHz to 3.2 GHz 24 18 17 -- -- -- 3.2 GHz to 10 GHz 23 14 13 -- -- -- 10 GHz to 16 GHz 16 12 10 -- -- -- 16 GHz to 24 GHz 16 10 9 -- -- -- 24 GHz to 26.5 GHz 16 8 8 -- -- -- Table 5b. Error Terms (dB), All Ports, All Options - Typical Source Transmission Reflection Description Directivity Load Match Crosstalk Match Tracking Tracking 10 MHz to 50 MHz 23 17 16 +/- 1.5 +/- 1.5 -84 50 MHz to 100 MHz 29 29 28 +/- 1.5 +/- 1.5 -90 100 MHz to 500 MHz 29 29 28 +/- 1.5 +/- 1.5 -110 500 MHz to 3.2 GHz 31 24 22 +/- 1.5 +/- 1.5 -120 3.2 GHz to 10 GHz 25 19 17 +/- 1.5 +/- 1.5 -122 10 GHz to 13.5 GHz 21 17 15 +/- 1.5 +/- 1.5 -122 13.5 GHz to 16 GHz 20 16 15 +/- 1.5 +/- 1.5 -122 16 GHz to 20 GHz 20 15 15 +/- 1.5 +/- 1.5 -122 20 GHz to 24 GHz 19 13 13 +/- 1.5 +/- 1.5 -117 24 GHz to 26.5 GHz 20 13 13 +/- 1.5 +/- 1.5 -114 13 14 Test Port Output See Block diagrams for all models and option beginning on page 41. Table 6. Frequency Information, All Options Description Specification Typical N5221A Frequency Range 10 MHz to 13.5 GHz -- N5222A Frequency Range 10 MHz to 26.5 GHz -- Frequency Resolution 1 Hz -- Frequency Accuracy +/- 1 ppm -- 1 +/-0.05 ppm, -10° to 70° C Frequency Stability -- 2 +/-0.1 ppm/yr maximum 1 Assumes no variation in time. 2 Assumes no variation in temperature. Table 7a. Maximum Leveled Power (dBm) - Specification Description Option 200, 400, 201, 401 Option 217, 417, 219, 419 +/-0.1 ppm/yr maximum2 Port 1, Port 3 Port 2, Port 4 Port 1, Port 3 Port 2, Port 4 10 MHz to 50 MHz 12 12 12 12 50 MHz to 16 GHz 13 13 13 13 16 GHz to 20 GHz 13 12 10 10 20 GHz to 24 GHz 13 10 10 7 24 GHz to 26.5 GHz 7 5 4 2 15 Table 7b. Maximum Leveled Power (dBm) - Typical Description Option 200, 400, 201, 401 Option 217, 417, 219, 419 Port 1, Port 3 Port 2, Port 4 Port 1, Port 3 Port 2, Port 4 10 MHz to 50 MHz 20 17 20 17 50 MHz to 500 MHz 20 18 20 18 500 MHz to 1 GHz 20 20 19 20 1 GHz to 3.2 GHz 19 20 19 20 3.2 GHz to 10 GHz 22 21 22 21 10 GHz to 13.5 GHz 22 19 21 18 13.5 GHz to 16 GHz 20 18 19 17 16 GHz to 20 GHz 20 16 18 14 20 GHz to 24 GHz 18 14 16 12 24 GHz to 26.5 GHz 14 11 12 9 Table 8. Power Level Accuracy (dB), All Options Description Specification Typical 10 MHz to 50 MHz +/- 1.0 +/- 0.5 50 MHz to 500 MHz +/- 1.0 +/- 0.2 500 MHz to 3.2 GHz +/- 1.0 +/- 0.1 3.2 GHz to 10 GHz +/- 1.0 +/- 0.2 10 GHz to 13.5 GHz +/- 1.2 +/- 0.2 13.5 GHz to 18 GHz +/- 2.0 +/- 0.3 18 GHz to 26.5 GHz +/- 2.5 +/- 0.4 Table 9a. Power Level Linearity (dB), All Options - Specification 1 1 1 Port 1 or 3 Port 1 or 3 Port 1 or 3 Description -25dBm ≤ P<-20dBm -20dBm ≤ P<-15dBm P ≥-15dBm 10 MHz to 50 MHz +/-2.0 +/-1.5 +/-1.5 50 MHz to 26.5 GHz +/-1.5 +/-1.5 +/-1.5 1 Either port can be used as the source port. 16 Table 9b. Power Level Linearity (dB), All Options - Specification 1 1 1 Port 2 or 4 Port 2 or 4 Port 2 or 4 Description -25dBm ≤ P<-20dBm -20dBm ≤ P<-15dBm P ≥-15dBm 10 MHz to 50 MHz +/-2.5 +/-1.5 +/-1.5 50 MHz to 500 MHz +/-2.0 +/-1.5 +/-1.5 500 MHz to 26.5 GHz +/-1.5 +/-1.5 +/-1.5 1 Either port can be used as the source port. Table 10a. Power Sweep Range (dB), All Options - Specification Description Option 200, 400, 201, 401 Option 217, 417, 219, 419 Port 1, Port 3 Port 2, Port 4 Port 1, Port 3 Port 2, Port 4 10 MHz to 50 MHz 37 37 37 37 50 MHz to 16 GHz 38 38 38 38 16 GHz to 20 GHz 38 37 35 35 20 GHz to 24 GHz 38 35 35 32 24 GHz to 26.5 GHz 32 30 29 27 Table 10b. Power Sweep Range (dB), All Options - Typical Description Option 200, 400, 201, 401 Option 217, 417, 219, 419 Port 1, Port 3 Port 2, Port 4 Port 1, Port 3 Port 2, Port 4 10 MHz to 50 MHz 47 44 47 44 50 MHz to 500 MHz 47 45 47 45 500 MHz to 1 GHz 47 47 46 47 1 GHz to 3.2 GHz 46 47 46 47 3.2 GHz to 10 GHz 49 48 49 48 10 GHz to 13.5 GHz 49 46 48 45 13.5 GHz to 16 GHz 47 45 46 44 16 GHz to 20 GHz 47 43 45 41 20 GHz to 24 GHz 45 41 43 39 24 GHz to 26.5 GHz 41 38 39 36 17 Table 11. Nominal (Preset) Power (dBm) Description Option 200, 201, 400, 401 Option 217, 219, 417, 419 Preset Power 0 -5 Table 12. Power Resolution and Maximum/Minimum Settable Power, All Options Description Specification (dB) Typical (dBm) Power Resolution 0.01 -- Maximum Settable Power -- 30 Minimum Settable Power Option 200, 201, 400, 401 -- -30 Option 217, 219, 417, 419 -- -95 nd rd Table 13. 2 and 3 Harmonics at Max Specified Power (dBc) All Options - Typical Listed frequency is harmonic frequency; test at max specified power Description N5221A N5222A 20 MHz to 4 GHz -15 -15 4 GHz to 13.5 GHz -19 -19 13.5 GHz to 24 GHz -- -19 24 GHz to 26.5 GHz -- -21 Table 14. Non-Harmonic Spurs at Nominal Power (dBc), All Options - Typical Offset frequency = 30 kHz to 5 MHz Description Based on 8kHz offset Frac-N Based on 100kHz offset Frac-N 10 MHz to 500 MHz -50 -50 500 MHz to 2 GHz -60 -42 2 GHz to 4 GHz -57 -45 4 GHz to 8 GHz -51 -39 8 GHz to 16 GHz -45 -33 16 GHz to 26.5 GHz -39 -27 18 Table 15. Phase Noise (dBc/Hz), All Options - Typical Description 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz to 50 MHz -100 -95 -95 -120 50 MHz to 1 GHz -107 -117 -112 -127 1 GHz to 2 GHz -101 -111 -106 -121 2 GHz to 4 GHz -95 -105 -100 -115 4 GHz to 8 GHz -89 -99 -94 -109 8 GHz to 16 GHz -83 -93 -88 -103 16 GHz to 26.5 GHz -77 -87 -82 -97 19 Test Port Input Table 16. Test Port Noise Floor (dBm) @ 10 Hz IFBW, All Options Total average (rms) noise power calculated as the mean value of a linear magnitude trace expressed in dBm. May typically be degraded at particular frequencies below 500 MHz due to spurious receiver residuals. Description Specification Typical N5221A N5222A N5221A N5222A 10 MHz to 50 MHz -82 -82 -88 -88 50 MHz to 100 MHz -95 -95 -103 -103 100 MHz to 500 MHz -105 -105 -110 -110 500 MHz to 2 GHz -114 -114 -118 -118 2 GHz to 13.5 GHz -114 -114 -119 -119 13.5 GHz to 20 GHz -- -114 -- -120 20 GHz to 24 GHz -- -111 -- -118 24 GHz to 26.5 GHz -- -107 -- -116 Table 17. Direct Receiver Access Input Noise Floor (dBm), Options 201, 217, 219, 401, 417, 419 Total average (rms) noise power calculated as the mean value of a linear magnitude trace expressed in dBm. May typically be degraded at particular frequencies below 500 MHz due to spurious receiver residuals. Description Specification Typical N5221A N5222A N5221A N5222A 10 MHz to 50 MHz -118 -118 -133 -133 50 MHz to 100 MHz -107 -107 -129 -129 100 MHz to 250 MHz -117 -117 -136 -136 250 MHz to 500 MHz -117 -117 -130 -130 500 MHz to 2 GHz -126 -126 -133 -133 2 GHz to 13.5 GHz -126 -126 -134 -134 13.5 GHz to 20 GHz -- -126 -- -135 20 GHz to 24 GHz -- -123 -- -133 24 GHz to 26.5 GHz -- -119 -- -131 20 Table 18a. 0.1 dB Receiver Compression at Test Port (dBm), Option 201, 217, 219, 401, 417, 419 - Typical Description N5221A N5222A 10 MHz to 100 MHz 15 15 100 MHz to 13.5 GHz 12 12 13.5 GHz to 20 GHz -- 12 20 GHz to 26.5 GHz -- 10 Table 18b. Receiver Compression at Test Port Power - Specification Description Test Port Power (dBm) Receiver Compression Option 200, 400 Magnitude (dB) Phase (degrees) 1 10 MHz to 500 MHz -- -- -- 500 MHz to 16 GHz 8 0.21 1.60 16 GHz to 24 GHz 8 0.24 1.73 24 GHz to 26.5 GHz 8 0.42 2.51 1 Test port receiver compression at specified input levels below 500 MHz due to coupler roll off in this frequency range. Table 18c. Receiver Compression at Test Port Power - Specification Description Test Port Power (dBm) Receiver Compression Option 201, Option 217, Option 219, Magnitude Phase 401 417 419 (dB) (degrees) 1 10 MHz to 500 MHz -- -- -- -- -- 500 MHz to 16 GHz 8 8 8 0.17 0.97 16 GHz to 24 GHz 8 8 8 0.23 1.20 24 GHz to 26.5 GHz 8 8 8 0.29 1.74 1 Test port receiver compression at specified input levels below 500 MHz due to coupler roll off in this frequency range. 21 Table 19. Trace Noise Magnitude (dB rms) Ratioed measurement, nominal power at test port. Description Specification Typical 1 kHz IFBW 1 kHz IFBW 100 kHz IFBW 600 kHz IFBW 10 MHz to 100 MHz 0.007 0.0036 0.053 0.103 100 MHz to 13.5 GHz 0.002 0.0005 0.004 0.010 13.5 GHz to 16 GHz 0.002 0.0003 0.003 0.007 16 GHz to 22.5 GHz 0.002 0.0005 0.003 0.007 22.5 GHz to 24 GHz 0.003 0.0008 0.004 0.011 24 GHz to 26.5 GHz 0.005 0.0012 0.007 0.017 Table 20. Trace Noise Phase (deg rms) Ratioed measurement, nominal power at test port. Description Specification Typical 1 kHz IFBW 1 kHz IFBW 100 kHz IFBW 600 kHz IFBW 10 MHz to 100 MHz 0.051 0.0237 0.341 0.663 100 MHz to 13.5 GHz 0.015 0.0045 0.027 0.067 13.5 GHz to 16 GHz 0.042 0.0045 0.019 0.042 16 GHz to 22.5 GHz 0.042 0.0075 0.024 0.050 22.5 GHz to 24 GHz 0.054 0.0080 0.031 0.073 24 GHz to 26.5 GHz 0.054 0.0128 0.049 0.118 Table 21. Reference Level Magnitude, All Options - Specification Description Magnitude (dB) Phase (degrees) Range +/- 500 +/- 500 Resolution 0.001 0.01 22 Table 22. Stability, All Options - Typical Description Magnitude (dB/°C) Phase (°/°C) 10 MHz to 50 MHz 0.010 0.180 50 MHz to 500 MHz 0.010 0.060 500 MHz to 3.2 GHz 0.010 0.080 3.2 GHz to 10 GHz 0.020 0.130 10 GHz to 13.5 GHz 0.020 0.160 13.5 GHz to 16 GHz 0.020 0.300 16 GHz to 20 GHz 0.020 0.400 20 GHz to 24 GHz 0.030 0.500 24 GHz to 26.5 GHz 0.030 0.560 Table 23. Damage Input Level Description Option 200, 201, 219, 400, 401, 419 Option 217, 417 RF , DC 30 dBm, 40 V 30 dBm, 7 V 23 Dynamic Accuracy Dynamic accuracy is verified with the following measurements: Compression over frequency IF linearity at a single frequency of 1.998765GHz using a reference level of -20 dBm for an input power range of 0 to -60 dBm. For values below -60 dBm, refer to “VNA Receiver Dynamic Accuracy Specifications and Uncertainties Table 24. N5221A and N5222A Dynamic Accuracy N5221A/22A Dynamic Accuracy, 10 MHz to 50 MHz - Specification N5221A/22A Dynamic Accuracy, 50 MHz to 500 MHz - Specification N5221A/22A Dynamic Accuracy, 500 MHz to 1 GHz - Specification 24 N5221A/22A Dynamic Accuracy, 1 GHz to 2 GHz - Specification N5221A/22A Dynamic Accuracy, 2 GHz to 20 GHz - Specification N5221A/22A Dynamic Accuracy, 20 GHz to 26.5 GHz - Specification 25 Table 25. Group Delay - Typical Group delay is computed by measuring the phase change within a specified frequency step (determined by the frequency span and the number of points per sweep). In general, the following formula can be used to determine the accuracy, in seconds, of specific group delay measurement: ±Phase Accuracy (deg)/[360 × Aperture (Hz)] Depending on the aperture and device length, the phase accuracy used is either incremental phase accuracy or worst- case phase accuracy Description Typical Performance Aperture (selectable) (frequency span)/(number of points -1) Maximum Aperture 20% of frequency span Range 0.5 x (1/minimum aperture) Maximum Delay Limited to measuring no more than 180° of phase change within the minimum aperture.) The following graphs show characteristic group delay accuracy with full 2-port calibration and a 10 Hz IF bandwidth. Insertion loss is assumed to be < 2 dB and electrical length to be ten meters. For any S Group Delay measurement, S = 0, S = 1, S = 0, S = 0 for all kl lij ij ii ij ji kl 26 General Information Miscellaneous Information Front Panel Rear Panel Environment and Dimensions Table 26. Miscellaneous Information Description Supplemental Information System IF 1 Hz to 15 MHz, nominal Bandwidth Range CPU Intel ® 2.0 GHz Core ® i7 - Note: Some instruments may have a more advanced microprocessor than listed here. For the latest information on CPUs and associated hard drives, visit http://na.tm.agilent.com/pna/hdnumbers.html LXI Class C Table 27. Front Panel Information, All Options Description Typical Performance RF Connectors Type 3.5 mm (male), 50 ohm, (nominal) Center Pin Recession 0.002 in. (characteristic) USB 2.0 Ports - Master (4 ports) Standard Compatible with USB 2.0 Connector USB Type-A female Display Size 26.3 cm (10.4 in) diagonal color active matrix LCD; 1024 (horizontal) X 768 (vertical) resolution Refresh Rate Vertical 60 Hz; Horizontal 46.08 kHz Pixels Any of the following would cause a display to be considered faulty: • A complete row or column consists of “stuck” or “dark” pixels. • More than six “stuck on” pixels (but not more than three green) or more than 0.002% of the total pixels are within the LCD specifications. • More than twelve “dark” pixels (but no more than seven of the same color) or more than 0.004% of the total pixels are within the LCD specifications. • Two or more consecutive "stuck on" pixels or three or more consecutive "dark" pixel (but no more than one set of two consecutive dark pixels) • “Stuck on” “dark” pixels are less than 6.5 mm apart (excluding consecutive pixels) 27 Table 27. (Continued) Front Panel Information, All Options Description Typical Performance Display Range Magnitude +/-2500 dB (at 500 dB/div), max Phase +/-2500° (at 500 dB/div), max Polar 10 pUnits, min 10,000 Units, max Display Resolution Magnitude 0.001 dB/div, min Phase 0.01°/div, min Marker Resolution Magnitude 0.001 dB, min Phase 0.01°, min Polar 10 pUnit, min Table 28. Rear Panel Information, All Options Description Typical Performance 10 MHz Reference In Connector BNC, female Input Frequency 10 MHz ± 10 ppm Input Level -15 dBm to +20 dBm Input Impedance 200 , nom. 10 MHz Reference Out Connector BNC, female Output Frequency 10 MHz ± 1 ppm Signal Type Sine Wave Output Level +10 dBm ± 4 dB into 50 Output Impedance 50 , nominal Harmonics <-40 dBc, typical 28 Table 28. (Continued) Rear Panel Information, All Options Description Typical Performance External IF Inputs Function Allows use of external IF signals from remote mixers, bypassing the PNA's first converters Connectors SMA (female); A, B, C, D, R (4-port); A, B, R1, R2 (2-port) Input Frequency Normal IF path RF < 53 MHz: IF = 826.446 KHz RF >= 53 MHz: IF = 7.438 MHz Narrowband IF path IF = 10.70 MHz 50 Input Impedance RF Damage Level +23 dBm DC Damage Level 5.5 VDC 0.1 dB Compression Point Normal IF path -9.0 dBm at 7.438 MHz Narrowband IF path -17 dBm at 10.70 MHz Pulse Inputs (IF Gates) Function Internal receiver gates used for point-in-pulse and pulse-profile measurements Connectors 15-pin mini D-sub Input Impedance 1 K Ohm Minimum Pulse Width, 33 ns Source Modulators Minimum Pulse Width, 20 ns Receiver Gates DC Damage Level 5.5 VDC Drive Voltage 0 V (off), +3.3 V (on), nominal RF Pulse Modulator Input (Source Modulator) On/Off Ratio 10 MHz to 3.2 GHz -64 3.2 GHz to 26.5 GHz -80 Pulse Period Minimum 33 ns Maximum 70 s 29 Table 28. (Continued) Rear Panel Information, All Options Description Typical Performance Pulse Outputs Voltage (TTL) High: 3.3V to 3.5V Low: <1V Impedance 50 Ohm External Test Set Driver Function Used for driving remote mixers Connections 3.5 mm (female) RF Output Frequency 3.2 GHz to 19 GHz Range LO Output Frequency 1.76 GHz to 26.5 GHz Range 1 Rear Panel LO Power Upper Limit, Typical (dBm) Lower Limit, Typical (dBm) 1.7 GHz to 16 GHz 0 -10 16 GHz to 21 GHz 4 -6 21 GHz to 26.5 GHz 6 -4 Rear Panel RF Power Upper Limit, Typical (dBm) Lower Limit, Typical (dBm) 3.2 GHz to 19 GHz -3 -8 VGA Video Output Connector 15-pin mini D-Sub; Drives VGA compatible monitors Devices Supported Resolutions Flat Panel (TFT) 1024 X 768, 800 X 600, 640 X 480 Flat Panel (DSTN) 800 X 600, 640 X 480 CRT Monitor 1280 X 1024, 1024 X 768, 800 X 600, 640 X 480 Simultaneous operation of the internal and external displays is allowed, but with 640 X 480 resolution only. If you change resolution, you can only view the external display (internal display will "white out"). 1 LO output available in full analyzer’s frequency range. The power is tested only from 3.2 GHz to 26.5 GHz. 30 Table 28. (Continued) Rear Panel Information, All Options Description Typical Performance Bias Tee Inputs Connectors BNC(f) for ports 1, 2, 3 and 4 Fuse 500 mA, bi-pin style Maximum Bias Current +/-200 mA with no degradation of RF specifications Maximum Bias Voltage +/-40 VDC Trigger Inputs/Outputs BNC(f), TTL/CMOS compatible Test Set IO 25-pin D-Sub connector, available for external test set control. Power IO 9-pin D-Sub, female; analog and digital IO Handler IO 36-pin parallel I/O port; all input/output signals are default set to negative logic; can be reset to positive logic via GPIB command. GPIB Two ports - dedicated controller and dedicated talker/listener. 24-pin D-sub (Type D-24), female; compatible with IEEE-488. Parallel Port (LPT1) 25-pin D-Sub miniature connector, female; provides connection to printers or any other parallel port peripherals USB Ports Four ports on front panel (all Host) and five ports (four Host and one Device) on rear panel. Type A configuration (eight Host) and Type B configuration (one Device), USB 2.0 compatible. The total current limit for all rear panel USB ports is 2.0 amps. The total current limit for all front panel USB is 0.9 amps. LAN 10/100BaseT Ethernet, 8-pin configuration; auto selects between the two data rates Line Power Frequency, Voltage 50/60/400 Hz for 100 to 120 VAC 50/60 Hz for 220 to 240 VAC Power supply is auto switching Max 450 watts 31 Table 29. Analyzer Dimensions and Weight All models are shipped with handles. Cabinet Dimensions Metric (mm) Imperial (inches) Height Without bottom feet: 266.1 10.5 1 EIA RU = 6 With bottom feet 279.1 11.0 Width Without handles or rack-mount flanges 425.6 16.8 With handles, without rack-mount flanges 458.7 18.1 With handles and rack-mount flanges 482.9 19.0 Depth Without front and rear panel hardware 533.0 21.0 With front and rear panel hardware, handles 578.0 22.7 1 Electronics Industry Association rack units. 1 RU = 1.75 in. See detailed PNA dimension drawings at: http://na.tm.agilent.com/pna/PNADimensions.pdf Weight (nominal) Net Shipping 2-port models (Option 200, 201, 217 or 219) 27 kg (60 lb) 43 kg (95 lb) 4-port models (Option 400, 401, 417 or 419) 36.7 kg (81 lb) 51 kg (112 lb) Regulatory and Environmental Information For Regulatory and Environmental information, refer to the PNA Series Installation and Quick Start Guide, located online at http://cp.literature.agilent.com/litweb/pdf/E8356-90001.pdf. 32 Measurement Throughput Summary Typical Cycle Time for Measurement Completion Cycle Time vs. IF Bandwidth Cycle Time vs. Number of Points Data Transfer Time Cycle time Includes sweep time, retrace time and band-crossing time. Analyzer display turned off with DISPLAY:ENABLE OFF. Add 21 ms for display on. Data for one trace (S11) measurement. Table 30a. Typical Cycle Time (ms) for Measurement Completion, All Models and Options Number of Points Sweep IF Range Bandwidth 201 401 1601 16001 32001 Uncorrected 6.3 6.3 10.9 68 132 600 kHz 2-Port cal 18.8 20.3 30 145 275 Uncorrected 29.7 54.7 205 2000 4000 9 GHz to 10 kHz 10 GHz 2-Port cal 67 117 417 4031 8047 Uncorrected 227 445 1742 17031 33844 1 kHz 2-Port cal 462 900 3500 34102 67734 Uncorrected 18.8 18.8 23 70 133 600 kHz 2-Port cal 45.3 46.9 55 180 313 Uncorrected 69 127 270 2009 4009 10 GHz to 10 kHz 20 GHz 2-Port cal 145 263 548 4030 8055 Uncorrected 234 458 1781 17383 34531 1 kHz 2-Port cal 477 922 3578 34789 69109 33 Table 30b. N5221A Typical Cycle Time (ms) for Full-Span Measurement Completion 10 MHz to 13.5 GHz Number of Points IF Bandwidth 201 401 1601 16001 32001 Uncorrected 6.9 7.2 11.9 69 132 600 kHz 2-Port cal 22.2 23.1 32.2 148 275 Uncorrected 59 61 205 2004 4003 10 kHz 2-Port cal 126 130 418 4019 8020 Uncorrected 204 402 1593 15877 31751 1 kHz 2-Port cal 416 813 3194 31766 63539 Table 30c. N5222A Typical Cycle Time (ms) for Full-Span Measurement Completion 10 MHz to 26.5 GHz Number of Points IF Bandwidth 201 401 1601 16001 32001 Uncorrected 43 50 68 141 198 600 kHz 2-Port cal 93 107 141 284 405 Uncorrected 80 142 480 2184 4125 10 kHz 2-Port cal 168 291 964 4378 8297 Uncorrected 245 472 1809 17508 34773 1 kHz 2-Port cal 498 950 3622 35047 69609 34 Table 31. Cycle Time vs. IF Bandwidth - Typical Applies to the Preset condition (201 points, correction off) except for the following changes: CF = 10 GHz Span = 100 MHz Display off (add 21 ms for display on) Cycle time includes sweep and retrace time. Description N5221A/22A IF Bandwidth (Hz) Cycle Time (ms) Trace Noise Magnitude (dB rms) 600,000 5.6 0.0045 100,000 6.9 0.0018 30,000 10 0.0011 10,000 26.7 0.0006 3,000 72 0.0004 1,000 223 0.0003 300 641 0.0002 100 1825 0.0002 30 5984 0.0002 10 17836 0.0002 3 59281 0.0002 35 Table 32. Cycle Time vs. Number of Points - Typical Applies to the Preset condition (correction off) except for the following changes: CF = 10 GHz Span = 100 MHz Display off (add 21 ms for display on) Cycle time includes sweep and retrace time. Description IF Bandwidth (Hz) Number of Points 1,000 10,000 30,000 600,000 3 7.5 5.9 5.9 5.9 11 15.6 6.6 5.9 5.9 51 60 10.6 5.9 5.9 101 114 16.9 7.2 6.3 201 223 29.4 9.7 6.3 401 437 54.7 15 6.9 801 862 105 25.3 7.8 1,601 1706 203 45.9 11 6,401 6728 803 169 30 16,001 16669 2003 416 68 32,001 33106 4003 828 130 36 Table 33. Data Transfer Time (ms) - Typical Measured with the analyzer display off. Values will increase slightly if the analyzer display is on. Number of Points Description 201 401 1601 16,001 32,001 2 SCPI over GPIB (Program executed on external PC ) 32-bit floating point 4.6 9.3 38 352 720 64-bit floating point 9.4 18.8 73.4 730 1455 ASCII 36.7 72.5 288 2882 5762 1 SCPI over SICL/LAN or TCP/IP Socket (Program executed in the analyzer) 32-bit floating point <1 <1 <1 1.2 2.4 64-bit floating point <1 <1 <1 2.3 4.6 ASCII 2.1 4 15 148 295 1 COM (Program executed in the analyzer) 32-bit floating point <1 <1 <1 <1 <1 Variant type <1 <1 1.4 12.4 25.5 1 DCOM over LAN (Program executed on external PC) 32-bit floating point <1 <1 <1 2.3 4.4 Variant type <1 1.6 5.3 52 105.5 1 Values are for real and imaginary pairs, with the analyzer display off, using Gigabit Ethernet. Note: Specifications for Recall & Sweep Speed are not provided for the N522xA analyzers. 37 Specifications: Front-Panel Jumpers The following options have front-panel jumpers for each port: 201, 217, 219, 401, 417, 419 Measurement Receiver Inputs Reference Receiver Inputs and Reference Source Outputs Source Outputs Coupler Inputs Damage Level Table 34. Measurement Receiver Inputs (dBm) – Typical (RCVR A, B, C, D IN) @ 0.1dB Typical Compression Description All Options 10 MHz to 500 MHz -4 500 MHz to 3.2 GHz -2 3.2 GHz to 10 GHz -3 10 GHz to 13.5 GHz -4 13.5 GHz to 26.5 GHz -5 38 Table 35. Reference Receiver Inputs and Reference Source Outputs (dBm) - Typical (RCVR R1 IN, REF 1 SOURCE OUT) @ Max Specified Output Power Description Option 201, 401 Option 217, 219, 417, 419 10 MHz to 50 MHz -4 -4 50 MHz to 10 GHz -3 -2 10 GHz to 16 GHz -4 -2 16 GHz to 20 GHz -5 -6 20 GHz to 24 GHz -6 -7 24 GHz to 26.5 GHz -14 -14 Table 36. Reference Receiver Inputs and Reference Source Outputs (dBm) - Typical (RCVR R2 IN, RCVR R3 IN, RCVR R4 IN, REF 2 SOURCE OUT, REF 3 SOURCE OUT, REF 4 SOURCE OUT) @ Max Specified Output Power Description Option 201, 401 Option 401 Option 217, 219, 417, 419 RCVR R2 IN, RCVR R2 IN, RCVR R3 IN, RCVR R3 IN, RCVR R4 IN, RCVR R4 IN, REF 3 SOURCE OUT REF 3 SOURCE OUT REF 2 SOURCE OUT, REF 2 SOURCE OUT, REF 4 SOURCE OUT REF 4 SOURCE OUT 10 MHz to 50 MHz -2 -2 -2 -2 50 MHz to 500 MHz -1 -1 -1 -1 500 MHz to 3.2 GHz -1 -1 0 0 3.2 GHz to 10 GHz 0 0 +1 +1 10 GHz to 16 GHz 0 0 +2 +2 16 GHz to 20 GHz 0 +1 -1 -1 20 GHz to 24 GHz -2 +1 -3 0 24 GHz to 26.5 GHz -8 -6 -9 -7 39 Table 37. Source Outputs (dBm) - Typical (PORT 1 SOURCE OUT, PORT 2 SOURCE OUT, PORT 3 SOURCE OUT, PORT 4 SOURCE OUT) @ Max Specified Output Power Description Option 201, 401 Option 201, 401 Option 217, 219, 417, 419 PORT 1 SOURCE PORT 2 SOURCE PORT 1 SOURCE PORT 2 SOURCE OUT, PORT 3 OUT, PORT 4 OUT, PORT 3 OUT, PORT 4 SOURCE OUT SOURCE OUT SOURCE OUT SOURCE OUT 10 MHz to 50 MHz +12 +12 +12 +12 50 MHz to 500 MHz +13 +13 +13 +13 500 MHz to 3.2 GHz +13 +13 +14 +14 3.2 GHz to 10 GHz +14 +14 +14 +14 10 GHz to 16 GHz +14 +14 +15 +15 16 GHz to 20 GHz +14 +13 +12 +12 20 GHz to 24 GHz +14 +11 +12 +9 24 GHz to 26.5 GHz +8 +6 +6 +4 Table 38. Coupler Inputs (dB) - Typical (PORT 1 CPLR THRU, PORT 2 CPLR THRU, PORT 3 CPLR THRU, PORT 4 CPLR THRU) Insertion Loss of Coupler Thru Description Option 201, 401 Option 217, 219, 417, 419 10 MHz to 50 MHz 0 -0.50 50 MHz to 100 MHz -0.25 -0.50 100 MHz to 500 MHz -0.25 -1.00 500 MHz to 3.2 GHz -0.50 -1.00 3.2 GHz to 10 GHz -0.75 -1.25 10 GHz to 13.5 GHz -1.00 -1.75 13.5 GHz to 16 GHz -1.00 -2.00 16 GHz to 20 GHz -1.20 -2.00 20 GHz to 24 GHz -1.30 -2.50 24 GHz to 26.5 GHz -1.50 -2.50 40 Table 39. Damage Level - Typical Description RF (dBm) DC (V) RCVR A, B, C, D IN 15 7 RCVR R1, R2, R3, R4 IN 15 7 REF 1 SOURCE OUT 15 7 REF 2, 3, 4 SOURCE OUT 30 7 PORT 1, 2, 3, 4 SOURCE OUT 30 7 1 PORT 1, 2, 3, 4 CPLR THRU 30 40 (7 ) PORT 1, 2, 3, 4 CPLR ARM 30 7 1 With a thru connection between test ports of option 217 or 417 configuration, 7 VDC input to CPLR THRU ports damages the source attenuator on the connected port.. 41 Test Set Block Diagrams NOTE: For best readability, use a color printer for printing the following graphics. Legend N5221A and N5222A Option 200 (2-port base model) N5221A and N5222A Option 201 To base model, adds front-panel jumpers and R1 receiver switch 42 N5221A and N5222A Option 217 To base model, adds front-panel jumpers, R1 receiver switch, and source and receiver attenuators (extended power range). N5221A and N5222A Option 219 To base model, adds front-panel jumpers, R1 receiver switch, source and receiver attenuators (extended power range), and bias-tees. 43 N5221A and N5222A Option 400 (4-port base model) N5221A and N5222A Option 401 To base model, adds front-panel jumpers and R1 receiver switch 44 N5221A and N5222A Option 417 To base model, adds front-panel jumpers, R1 receiver switch, and source and receiver attenuators (extended power range). N5221A and N5222A Option 419 To base model, adds front-panel jumpers, R1 receiver switch, source and receiver attenuators (extended power range), and bias-tees. 45 Receiver Block Diagram Narro Narrowb wband and filter filter A A A Dig Digit ital FI al FIR R An Anti ti- -alias alias ADC ADC IF f IF filte ilter r filt filter er IF gate IF gate Ext Extern ernal al IF input IF input 46 www.agilent.com Agilent Email Updates www.agilent.com/find/pnax www.agilent.com/find/emailupdates For more information on Agilent Technologies’ products, applications or services, please contact Get the latest information on the products your local Agilent office. The complete list is and applications you select. available at: www.agilent.com/find/contactus Americas . Canada (877) 894-4414 www.axiestandard.org Brazil (11) 4197 3500 AdvancedTCA© Extensions for Mexico 01800 5064 800 Instrumentation and Test (AXIe) is an open United States (800) 829-4444 standard that extends the AdvancedTCA for general purpose and semiconductor test. Asia Pacific Agilent is a founding member of the AXIe consortium. Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 www.lxistandard.org Malaysia 1 800 888 848 LAN eXtensions for Instruments puts the Singapore 1 800 375 8100 power of Ethernet and the Web inside your Taiwan 0800 047 866 Other AP Countries test systems. Agilent is a founding member (65) 375 8100 of the LXI consortium. Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 www.pxisa.org France 0825 010 700* *0.125 €/minute PCI eXtensions for Instrumentation (PXI) Germany modular instrumentation delivers a rugged, 49 (0) 7031 464 6333 Ireland PC-based high-performance measurement 1890 924 204 Israel and automation system. 972-3-9288-504/544 Italy 39 02 92 60 8 484 Netherlands Agilent Channel Partners 31 (0) 20 547 2111 Spain 34 (91) 631 3300 www.agilent.com/find/channelpartners Sweden 0200-88 22 55 United Kingdom Get the best of both worlds: Agilent’s 44 (0) 118 9276201 measurement expertise and product For other unlisted countries: breadth, combined with channel partner convenience. www.agilent.com/find/contactus Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. Published in USA, Sept. 2, 2013 Supersedes: Feb. 25, 2013 N5221-90001

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the N5221A have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Agilent N1045A Plug-in Module

Agilent N1455-10002 WIN98 Certificate of Authenticity

product

Agilent N2864A Rack Mount - Rack mount kit for Agilent 3000 Series oscilloscopes

product

Agilent N2X Next Generation 10Gb/s Test Cards

product

Agilent N6732B-761 DC Power Module. Output Disconnect Relay | 8 Volts | 6.25 Amps | 50-100 watts