ACROMAG 461A-V1-DMRN-1-DIN-NCR
Datasheet
Extracted Text
Flat Pack Series 361A DC-Powered Limit Alarm Relay Trips 361A RELAY + NC IN COM – 3-way NO Isolation 10 to 36V DC 461A AC-Powered Limit Alarm 461A RELAY + NC IN COM – 3-way NO Isolation 115/230V AC 361A and 461A ■Special Features■Performance Limit Alarms ■100% adjustable setpoint via 15-turn pot ■Input These alarms accept DC voltage/current input handles more applications and provides better Input signals and provide relay output if the input resolution. -V1: 0 to 1V DC. 1M ohm input impedance or 0 to 20mA DC via exceeds user-defined setpoint limits. ■100% adjustable deadband via 15-turn pot 50 ohm internal resistor. Numerous options and features make these prevents false trips and eliminates alarm -V5: 0 to 5V DC. alarms easy to use and well-suited for a wide chatter. 1M ohm input impedance or 0 to 20mA DC via range of limit monitoring and on/off controller 250 ohm internal resistor. ■Setpoint test points are accessible on front of applications. Three-way isolation eliminates -V0: 0 to 10V DC. 100K ohm input impedance. unit for quick verification with digital voltmeter ground loops to simplify installation. And for -V50: 0 to 50V DC. 500K ohm input impedance. probe. easier use in the field, these alarms withstand -V100: 0 to 100V DC. 1M ohm input impedance. extreme temperatures and have accessible set-■Dual relays offer the flexibility of high/low, AC current sensor (5020-350) point voltage test points. Other features include high/high, or low/low alarm setpoint Used with -V1 input option only. alarm/power status LEDs and independent set- Input range is function of turns placed on sensor. operation. 1 turn = 0 to 20A AC; 2 turns = 0 to 10A; point and deadband adjustment pots. ■Three-way isolation eliminates ground loops. 4 turns = 0 to 5A; 10 turns = 0 to 2A. Setpoint adjust Models ■Jumper-selectable DC voltage or current input 0 to 115% of input span via 15-turn potentiometer. 361A: DC-powered reduces inventory stock. Resolution better than 0.1% of span, continuous. 461A: AC-powered Deadband adjust (hysteresis)■Jumper-selectable failsafe operation enables 1 to 100% of input span for each channel via 15-turn alarm actuation on power loss in critical Input Ranges potentiometer(s). Adjustments are independent on dual applications.■0 to 20mA DC alarm models. ■Wide power supply range (361A) handles■0 to 1V, 0 to 5V, 0 to 10V, 0 to 50V, Automatic reset (non-latching alarms) The alarm resets to its non-alarm state as soon as input more applications to reduce inventory stock. 0 to 100V DC signal is outside of the selected deadband. If the dead- ■DC power units (361A only) carry lower ■0 to 20A AC (with external AC current sensor) band is set to its extreme (100%), then the alarm is effectively latching and will not reset till the input signal voltages and do not require expensive conduit is at or below 0%. Output for safer and easier installation. Repeatability■Electromechanical SPDT dry contact sealed ■Diode-coupled power (361A only) supports the Repeatable to better than ±0.1% of input span relays; CSA rated for 5A use of redundant power supplies for critical Continued on the next page. applications. Power Requirements ■361A: 10 to 36V DC (0.9W max.) ■Excellent accuracy, stability and no loose internal wiring ensure reliable alarm trips. ■461A: 115V AC (0.0320A) or 230V AC (0.016A) Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 136 Flat Pack Flat Pack Limit Alarms ■Performance■Ordering Information Continued from the previous page. Select one option from each column. Example: 461A-V5-DMRN-1-DIN-NCR-C To order factory calibration, append “-C” to end of model number. Specify ranges on order. ■Output/Relays Output Base Input Output Mounting Approval -SMRN: Single alarm. Note: One SPDT dry-contact sealed relay. 361A -V1 -V50 -SMRN -DIN -NCR All 361As accept -DMRN: Dual Alarm, two SPDT relays. -V5 -V100 -DMRN 10 to 36V DC Electrical Life - CSA Ratings: -V0 power supply. 25V DC, 5A, 100,000 operations, resistive. Base Input Output Power Mounting Approval 48V DC, 0.8A, 100,000 operations, resistive. 120V AC, 5A, 30,000 operations, resistive. 461A -V1 -V50 -SMRN -1 -DIN -NCR 240V AC, 5A, 30,000 operations, resistive. -V5 -V100 -DMRN -2 Contact Material : Silver-cadmium oxide. -V0 Breakdown Voltage: Between open contacts: See Ordering Notes for model number descriptions. 1000VAC rms.Between contacts and coil: 1500VAC rms, 50-60 Hz for one minute. ■Environmental■Ordering Notes Mechanical Life: 20 million operations. Ambient temperature range Response time -13°F to 167°F (-25°C to 75°C). Input Options Fixed delay of 100mS (nominal). Relay transfers Ambient temperature effect -V1: 0 to 1V DC, 0 to 20mA DC, or ≤100mS, typical, after input signal exceeds setpoint. Less than ±0.01% of output span per °F (±0.018% 0 to 20A AC with AC current sensor Relay transfers within 50mS after input passes dead- per °C) over the ambient range. -V5: 0 to 5V DC or 0 to 20mA DC band, as it returns to normal range. Isolation -V0: 0 to 10V DC Three way; input, contacts, and power are isolated■Power -V50: 0 to 50V DC from each other for common mode voltages up to Power requirement (361A) -V100: 0 to 100V DC 250V AC, or 354V DC, continuous (withstands 1500V 10V to 36V DC. AC for sixty seconds without breakdown). Current draw is a function of supply voltage. Output Options Noise rejection Currents specified are maximum values with the -SMRN: One SPDT relay, single setpoint alarm Common mode: Better than 100dB at 60 Hz, 250ohm relay(s) energized. unbalance, typical. -DMRN: Two SPDT relays, dual setpoint alarm Supply Mechanical Relay Output Normal mode: 26dB at 60 Hz, 250ohm source, typical. Voltage Single Dual Power Options 10V 65mA 100mA RFI resistance -1: 115V AC power 12V 50mA 75mA Unit will not trip under influence of RFI when input is 15V 40mA 60mA ±0.5% of input span from setpoint voltage for RFI -2: 230V AC power 24V 30mA 40mA field strengths of up to 10V/meter, at frequencies of 36V 25mA 30mA Mounting Option 27MHz, 151MHz, and 467MHz. Power requirement (461A) -DIN: DIN rail G or T mount EMI resistance -1: 115V AC ±10%, 50 to 60Hz, 0.032A. Unit will not trip when input is ±0.25% of input span Approval Option -2: 230V AC ±10%, 50 to 60Hz, 0.032A. from setpoint voltage with switching solenoids or commutator motors. -NCR: No certification/approval required. Power supply effect (461A) Trip-point varies less than ±0.05% of input span. Surge withstand capability (SWC) Accessories Meets ANSI/IEEE C37.90-1978. Power supplies ■Physical See Power Supplies on page 183. Construction AC Current Sensor 5020-350 Circuit boards: Military grade FR-4 epoxy glass circuit AC current sensor. See Pg. 189 for more information. board, 0.063 inches thick. DIN RAIL 3.0 or DIN RAIL 16.7 Coating: Fungus resistant acrylic conformal coat. DIN rail strip, Type T, 3 inches (75mm) or Terminals: Compression type, wire 14 AWG max. 16.7 inches (425mm) Case: Self-extinguishing NYLON Type 6.6 polyamide ther- moplastic, UL94 V-2. NEMA 1 enclosure. 20RM-16-DIN Test points (setpoint): Accepts 0.080" dia. probe. 19" rack-mount kit with DIN rail. Holds ten alarms. Mounting position: Position insensitive. 350T-N4-WM NEMA 4 water-tight enclosure, wall-mount. Holds one 361A or 461A alarm. 350T-N12-WM NEMA 12 oil-tight enclosure, wall-mount. Holds one 361A or 461A alarm. Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 137 Flat Pack Series Dimensions Transmitters: 250T, 350T Isolators: 270i, 340i, Limit Alarms: 260A Power Supplies: 25PS, 35PS-2U Surface Mount: Snaptrack 250T-SM, Mount: 260A-SM, 250T-ST, 270i-SM, 260A-ST, 25PS-SM 270i-ST, 25PS-ST Dimensions are in inches (millimeters). Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 138 Flat Pack Flat Pack Signal Conditioners Dimensions Explosion-Proof and Industrial Housing 250T-XP, 260A-IH/IHW, 270i-XP 250T Transmitter shown installed in enclosure with cover removed. 250T Transmitter shown removed from enclosure. NEMA-4 and NEMA-12 Enclosures 250T-N4 / N12, 25PS-N4 / N12 260A-N4 / N12, 270i-N4 / N12 Dimensions are in inches (millimeters). Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 139 Flat Pack Series Dimensions Transmitters: 450T Isolators: 330i, 430i, Limit Alarms: 361A, 461A Power Supplies: 35PS-8U NEMA-4 and NEMA-12 Enclosures 350T-N4-WM 350T-N12-WM Dimensions are in inches (millimeters). Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 140 Flat Pack Flat Pack Signal Conditioners Dimensions 20RM-16-DIN Rack Mount Kit AC Sensor 5020-350 Dimensions are in inches (millimeters). Tel: 248-624-1541 Fax: 248-624-9234 e-mail: sales@acromag.com www.acromag.com 141
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the 461A-V1-DMRN-1-DIN-NCR have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods