Elite.Parts chervon right Manufacturers chervon right A chervon right ABB chervon right S272-K32
About product Specifications Datasheet FAQ

ABB S272-K32

Image of ABB S272-K32

Description

ABB S272-K32 CIRCUIT BREAKER - 2P 32A 480VAC

Part Number

S272-K32

Price

Request Quote

Manufacturer

ABB

Lead Time

Request Quote

Category

PRODUCTS - S

Specifications

Amps

32

Poles

2

Voltage

480VAC

Datasheet

pdf file

ABB-S272K32-datasheet-713716287.pdf

3170 KiB

Extracted Text

Line Protection Contents Miniature Circuit Breakers (MCB’s) ................................................ 3-2 Protecta Type B Pan Assemblies .................................................. 3-12 High Performance MCB’s.............................................................. 3-14 Residual Current Devices .............................................................. 3-19 RCBO’s ........................................................................................ 3-21 Residual Current Relays ................................................................ 3-23 Switch Disconnectors .................................................................... 3-24 Installation Contactors.................................................................... 3-25 Latching Relays.............................................................................. 3-26 Pushbuttons & Indicator Lamps .................................................... 3-27 Time Switches .............................................................................. 3-28 Power Failure Signalling Lamps...................................................... 3-29 Bell Transformers .......................................................................... 3-30 Twilight Switches .......................................................................... 3-31 Smissline........................................................................................ 3-32 Surge Protection............................................................................ 3-36 Technical Details............................................................................ 3-44 Dimensions.................................................................................... 3-46 ABB LIMITED 3/1 System ProM Overview Breaking capacities Short circuit rupturing capacity Switching sequence acc. to DIN VDE 0641 part 11, EN 60898, IEC 898 Ratings with AC in kA / cosj, with DC in kA / T ms 1) Range AC DC Max. Max. Tripping characteristic 1-Phase 2/3 phase Single Pole Back-up Short-circuit Rated current 133V~ 230V~ 230V~ 400V~ up to 60V Protection rupturing 133/230V~ 230/400V~ Main capacity of kA/cosjkA/cos jkA/cos jkA/cos jkA/T £ ms circuit the range 2) fuse breaker S260-B 6 63A 100A 10...20 100A 100A 6000 25...32 10/0.5 6/0.7 10/0.5 6/0.7 10/4 100A 100A 3 40 125A 100A 50...63 160A 100A S260-C, D 0.5...2 Unlimited not necessary unlimited 3...4 20A - 6 40A - 8 63A 100A 6000 10...20 10/0.5 6/0.7 10/0.5 6/0.7 10/4 100A 100A 3 25...32 100A 100A 40 125A 100A 50...63 160A 100A S270-B 6 63A 100A 10...20 80A 100A 10000 25...32 10/0.5 6/0.7 10/0.5 6/0.7 10/4 100A 100A 3 40 125A 100A 50...63 160A 100A S270-C 0.5...2 Unlimited not necessary unlimited 3...4 20A - 6 40A - 8 63A 100A 10000 10...20 10/0.5 10/0.5 10/0.5 10/0.5 10/4 80A 100A 3 25...32 100A 100A 40 125A 100A 50...63 160A 100A S270-K 0.5...2 Unlimited not necessary unlimited 3 20A - 4 25A - 6...10 63A 100A 16...20 10/0.5 6/0.7 10/0.5 6/0.7 10/4 80A 100A 6000 25...32 100A 100A 40 125A 100A 50...63 160A 100A S270-Z 0.5...2 Unlimited not necessary unlimited 3...4 20A - 6 35A 100A 8 40A 100A 10...16 10/0.5 6/0.7 10/0.5 6/0.7 10/4 63A 100A 6000 20...25 80A 100A 32...40 100A 100A 50...63 125A 100A www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/2 System ProM Overview Breaking capacities Short circuit rupturing capacity Switching sequence acc. to DINVDE 0641 part 11, EN 60898, IEC 898 Ratings with AC in kA / cos j, with DC in kA / T ms 1) Range AC DC Max. Max. Tripping characteristic 1-Phase 2/3 phase Single Pole Back-up Short-circuit Rated current 133V~ 230V~ 230V~ 400V~ up to 60V Protection rupturing 133/230V~ 230/400V~ Main capacity of kA/cos jkA/cos jkA/cos jkA/cos jkA/T £ ms circuit the range 2) fuse breaker S280-B 6 15/0.25 10/0.5 15/0.25 10/0.5 63 A 100 A 10/4 10...13 80 A 100 A up to 25/0.25 25/0.25 25/0.25 25/0.25 16...25 100 A 100 A 25000 15/4 32...40 20/0.25 15/0.25 20/0.25 15/0.25 125 A 100 A 50...63 15/0.25 10/0.25 15/0.25 10/0.5 10/4 160 A 100 A S280-C 0.5...2 Unlimited not necessary unlimited 3, 4 35 A - 15/0.25 10/0.5 15/0.25 10/0.5 6, 8 10/4 63 A 100 A 10, 13 80 A 100 A up to 25/0.25 25/0.25 25/0.25 25/0.25 16...25 100 A 100 A 25000 15/4 32...40 20/0.25 15/0.25 20/0.25 15/0.25 125 A 100 A 50...63 15/0.25 10/0.5 15/0.25 10/0.5 10/4 160 A 100 A 3) S280-K,Z,D 0.2...2 Unlimited not necessary unlimited 3 25 A - 4 35 A - 15/0.25 10/0.5 15/0.25 10/0.5 10/4 6 63 A 100 A up to 8 80 A 100 A 25000 10...20 25/0.25 25/0.25 25/0.25 25/0.25 15/4 100 A 100 A 25...32 20/.025 15/0.25 20/0.25 15/0.25 15/4 125 A 100 A 40...63 15/0.25 10/0.5 15/0.25 10/0.5 10/4 160 A 100 A 1) In symmetrical earth-ground AC networks 2 pole MCB’s (two poles in series) are applicable up to 100V . In this case the rated rupturing capacity is one step higher than the 1 pole version. Direction of connection is optional. 2) The max. back-up protection is only required if the prospective short circuit current may exceed the short circuit rupturing capacity of the MCB. 3) K from 0.2 A, Z from 0.5 A rated current. Short Circuit rupturing capacity Switching sequence according to DINVDE 0660 Part 101, IEC 947. For the short circuit rupturing capacities listed the time constant T = L/R £ 15 ms is valid in the case of DC. In the case of AC for 10kA; cosj³ 0.6 – for 8 and 6kA: cos j³ 0.8 and for 2kA: cos j³ 0.9. 4) S280 UC 1 pole 2/4 pole Max. fuse For DC up to up to for back-up 60V 100V 220V 60V 110V 220V 440V protection: For AC up to up to operating class 60V ~ 127V ~ 240V ~ 60V ~ 127V ~ 240V ~ 415V ~ gl (DINVDE 0636/IEC269) B6 ...25 A 10kA 10kA 6kA 10kA 10kA 10kA 6kA 100A 5) K, Z 0.2...2 A unlimited unlimited unlimited unlimited unlimited unlimited unlimited not neccessary K, Z 3...4 A 10kA 10kA 6kA 10kA 10kA 10kA 6kA 35A K, Z 6...8 A 10kA 10kA 6kA 10kA 10kA 10kA 6kA 63A K, Z 10...32 A 10kA 10kA 6kA 10kA 10kA 10kA 6kA 100A K, Z 40...63 A 6kA 6kA 4.5kA 10kA 6kA 6kA 4.5kA 125A 4) Back-up protection is only necessary when, at the point of installation the maximum rated short circuit rupturing capacity is expected to be exceeded 5) Z 0.5A...2A www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/3 System proM Miniature Circuit Breakers B, C, and D trip curves. BS EN 60898. Ratings 0.5 to 100A. Description, Installation and Task • Current limiting MCB’s with undelayed magnetic and delayed thermal trips, with fixed setting. Metal framed trip-free switching mechanism. • For installation in ABBProtecta Final Distribution Boards, Pan Assemblies or on symmetrical DIN rail. • Protection and control of electrical wires, cables and appliances in the case of overcurrent due to overloads and short circuits. Technical Data • Current ratings 0.5 to 100A at 30 degrees C to BS EN 60898. • Rated voltage 230 - 400V AC • Maximum operating voltage 440V AC, single pole 60V DC, double pole 110V DC. • Minimum operating voltage 12V AC/DC. • Breaking capacity: BS EN 60898 - S270B & C 10kA, S260D 6kA, S280B & C 6kA. • Mechanical service life: 20,000 operations 2 2 2 • Cable capaciy: 25mm up to 40A, 35mm for 50 and 63A, 50mm for 80 &100A. • Tightening torque: 2Nm up to 63A, 2.5Nm for 80 & 100A. • Ambient temperature: -25ºC to +55ºC. • Weight per pole: 0.125g up to 40A, 0.145g for 50 & 63A, 0.160 for 80 & 100A. • Dimensions: see page 3/46 • Accessories: see page 3/10, 3/11 • Add on earth leakage: see page 3/20 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/4 System proM Miniature Circuit Breakers B, C, and D trip curves. BS EN 60898. Ratings 0.5 to 100A. Type B (3-5 In) BS EN 60898. Small inrush or switching surges, heating loads, tungsten lighting Rated Breaking Single Pole Double Pole Triple Pole Four Pole Current (A) Capacity 6 10kA S271B6 S272B6 S273B6 S274B6 10 10kA S271B10 S272B10 S273B10 S274B10 13 10kA S271B13 S272B13 S273B13 S274B13 16 10kA S271B16 S272B16 S273B16 S274B16 20 10kA S271B20 S272B20 S273B20 S274B20 25 10kA S271B25 S272B25 S273B25 S274B25 32 10kA S271B32 S272B32 S273B32 S274B32 40 10kA S271B40 S272B40 S273B40 S274B40 50 10kA S271B50 S272B50 S273B50 S274B50 63 10kA S271B63 S272B63 S273B63 S274B63 80 6kA S281B80 S282B80 S283B80 S284B80 100 6kA S281B100 S282B100 S283B100 S284B100 Type C (5-10 In) BS EN 60898. Moderate switching surges for short durations Rated Breaking Single Pole Double Pole Triple Pole Four Pole Current (A) Capacity 0.5 10kA S271C0.5 S272C0.5 S273C0.5 S274C0.5 1 10kA S271C1 S272C1 S273C1 S274C1 2 10kA S271C2 S272C2 S273C2 S274C2 3 10kA S271C3 S272C3 S273C3 S274C3 4 10kA S271C4 S272C4 S273C4 S274C4 6 10kA S271C6 S272C6 S273C6 S274C6 10 10kA S271C10 S272C10 S273C10 S274C10 13 10kA S271C13 S272C13 S273C13 S274C13 16 10kA S271C16 S272C16 S273C16 S274C16 20 10kA S271C20 S272C20 S273C20 S274C20 25 10kA S271C25 S272C25 S273C25 S274C25 32 10kA S271C32 S272C32 S273C32 S274C32 40 10kA S271C40 S272C40 S273C40 S274C40 50 10kA S271C50 S272C50 S273C50 S274C50 63 10kA S271C63 S272C63 S273C63 S274C63 80 6kA S281C80 S282C80 S283C80 S284C80 100 6kA S281C100 S282C100 S283C100 S284C100 Type D (10-14 In) BS EN 60898. High inrush applications Rated Breaking Single Pole Double Pole Triple Pole Four Pole Current (A) Capacity 0.5 6kA S261D0.5 S262D0.5 S263D0.5 S264D0.5 1 6kA S261D1 S262D1 S263D1 S264D1 2 6kA S261D2 S262D2 S263D2 S264D2 3 6kA S261D3 S262D3 S263D3 S264D3 4 6kA S261D4 S262D4 S263D4 S264D4 6 6kA S261D6 S262D6 S263D6 S264D6 10 6kA S261D10 S262D10 S263D10 S264D10 13 6kA S261D13 S262D13 S263D13 S264D13 16 6kA S261D16 S262D16 S263D16 S264D16 20 6kA S261D20 S262D20 S263D20 S264D20 25 6kA S261D25 S262D25 S263D25 S264D25 32 6kA S261D32 S262D32 S263D32 S264D32 40 6kA S261D40 S262D40 S263D40 S264D40 50 6kA S261D50 S262D50 S263D50 S264D50 63 6kA S261D63 S262D63 S263D63 S264D63 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/5 System proM Miniature Circuit Breakers K tripping curve. BS EN 60947-2. UL 1077 File No E76126, CSA C22.2 No 235, Report No LR98793-9. ( 277/480 V ). Ratings 0.2 to 63A. Description The K characteristic - the optimal solution for the safe protection of motors. Motor protection can be achieved by the selection of the MCBwith the correct rated current corresponding to the motor data. The electro-magnetic trip is set in such a way that the motor starting current does not lead to tripping. As a result cable sizes can be reduced and moe importantly contactors can be used up to their AC3 rating without the need for additional thermal overload protection. Technical Data • Current ratings 0.2 to 63A at 20ºC to BSEN 60947-2 • Rated voltage 230 - 400V AC • Maximum operating voltage 440VAC, single pole 60V DC, double pole 110V DC • Minimum operating voltage 12VAC/DC • Breaking capacity: BSEN 60947-2 – S270K 6kA, S280K 0.2 - 8A 10kA, 10 to 20A 25kA, 25 to 32A 15kA, 40to 63A 10kA. • Mechanical service life: 20,000 operations. 2 2 2 • Cable capacity: S270K 25mm up to 40A, 35mm for 50 and 63A, S280K 35mm . • Tightening torque: 2Nm up to 63A • Ambient temperature: -25ºC to +55ºC • Weight per pole: 0.125g up to 40A, 0.145g for 50 & 63A. • Accessories: see page 3/10, 3/11 • Add on earth leakage: see page 3/20 Selection rule: (ratings for DOL motors) Standard [A] [A] [In] Motor KW at 380 V at 400V K-MCB The rated current of the K MCB has to be 0,06 0,22 0,2 0,2 below or equal the rated current of the 0,09 0,33 0,3 0,3 motor and above the working current 0,12 0,42 0,4 0,3 of the motor. 0,18 0,64 0,6 0,5 0,25 0,88 0,74 0,75/0,5 0,37 1,22 1,1 1 0,55 1,5 1,4 1 0,75 2 2 1,6/2,0 1,1 2,6 2,5 2 1,5 3,5 3,5 3 2,2 5 5 4 3 6,6 6,5 6 4 8,5 8,1 8 5,5 11,5 11 10 7,5 15,5 14,5 16/10 11 22 21 20 15 30 28 25 18,5 37 35 32 22 44 40 40 30 60 55 50 37 72 66 63 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/6 System proM Miniature Circuit Breakers K tripping curve. BS EN 60947-2. UL 1077 File No E76126, CSA C22.2 No 235, Report No LR98793-9. ( 277/480 V ). Ratings 0.2 to 63A. Type S270K (8-12 In) BS EN 60947-2. Protection of motors, transformers, lamps and cable. Rated Breaking Single Pole Double Pole Triple Pole Four Pole Current (A) Capacity 0.5 6kA S271K0.5 S272K0.5 S273K0.5 S274K0.5 1 6kA S271K1 S272K1 S273K1 S274K1 1.6 6kA S271K1.6 S272K1.6 S273K1.6 S274K1.6 2 6kA S271K2 S272K2 S273K2 S274K2 3 6kA S271K3 S272K3 S273K3 S274K3 4 6kA S271K4 S272K4 S273K4 S274K4 6 6kA S271K6 S272K6 S273K6 S274K6 8 6kA S271K8 S272K8 S273K8 S274K8 10 6kA S271K10 S272K10 S273K10 S274K10 16 6kA S271K16 S272K16 S273K16 S274K16 20 6kA S271K20 S272K20 S273K20 S274K20 25 6kA S271K25 S272K25 S273K25 S274K25 32 6kA S271K32 S272K32 S273K32 S274K32 40 6kA S271K40 S272K40 S273K40 S274K40 50 6kA S271K50 S272K50 S273K50 S274K50 63 6kA S271K63 S272K63 S273K63 S274K63 Type S280K (8-14 In) BS EN 60947-2. Protection of motors, transformers, lamps and cable. Rated Breaking Single Pole Double Pole Triple Pole Four Pole Current (A) Capacity 0.2 10kA S281K0.2 S282K0.2 S283K0.2 S284K0.2 0.3 10kA S281K0.3 S282K0.3 S283K0.3 S284K0.3 0.5 10kA S281K0.5 S282K0.5 S283K0.5 S284K0.5 0.75 10kA S281K0.75 S282K0.75 S283K0.75 S284K0.75 1 10kA S281K1 S282K1 S283K1 S284K1 1.6 10kA S281K1.6 S282K1.6 S283K1.6 S284K1.6 2 10kA S281K2 S282K2 S283K2 S284K2 3 10kA S281K3 S282K3 S283K3 S284K3 4 10kA S281K4 S282K4 S283K4 S284K4 6 10kA S281K6 S282K6 S283K6 S284K6 8 10kA S281K8 S282K8 S283K8 S284K8 10 25kA S281K10 S282K10 S283K10 S284K10 13 25kA S281K13 S282K13 S283K13 S284K13 16 25kA S281K16 S282K16 S283K16 S284K16 20 25kA S281K20 S282K20 S283K20 S284K20 25 15kA S281K25 S282K25 S283K25 S284K25 32 15kA S281K32 S282K32 S283K32 S284K32 40 10kA S281K40 S282K40 S283K40 S284K40 50 10kA S281K50 S282K50 S283K50 S284K50 63 10kA S281K63 S282K63 S283K63 S284K63 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/7 System proM Miniature Circuit Breakers UC range (Universal Current). BS EN 60947-2. UL 1077, File No E76126, CSA C22.2 No 235, Report No LR98793-9. Ratings 0.5 to 63A. Description The S280UC MCB’s can be used up to 220V DC for single pole (17.5mm) or up to 440V DC for double pole (35mm) with series connection of 2 poles. This enhanced DC performance is in addition to the AC performance. They differ from the standard devices in that they are fitted with a permanent magnet which assists in the forced extinguishing of the arc. It is therefore important that care is taken to observe the correct polarity and current flow direction when connecting these breakers. Technical Data • Current ratings 0.5 to 63A at 20ºC to BSEN 60947-2 • Rated voltage 230 - 400V AC • Maximum operating voltage 440V AC, single pole 220V DC, double pole 440VDC. • Minimum operating voltage 12V AC/DC • Breaking capacity: BS EN 60947-2 – 280UC 0.5 to 32A 6kA, 40 to 63A 4.5kA. • Mechanical service life: 20,000 operations. 2 • Cable capacity: S280UC35mm • Tightening torque: 2Nm up to 63A • Ambient temperature: -25ºC to + 55ºC • Weight per pole: 0.125g up to 40A, 0.145g for 50 & 63A. • Accessories: see page 3/10, 3/11 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/8 System proM Miniature Circuit Breakers UC range (Universal Current). BS EN 60947-2. UL 1077, File No E76126, CSA C22.2 No 235, Report No LR98793-9. Ratings 0.5 to 63A. Type S280UCK (10-14 In) BS EN 60947-2. Protection of motors, transformers, lamps and cable. Rated Breaking Single Pole Double Pole Current InA Capacity 0.5 6kA S281UCK0.5 S282UCK0.5 0.75 6kA S281UCK0.75 S282UCK0.75 1 6kA S281UCK1 S282UCK1 1.6 6kA S281UCK1.6 S282UCK1.6 2 6kA S281UCK2 S282UCK2 3 6kA S281UCK3 S282UCK3 4 6kA S281UCK4 S282UCK4 6 6kA S281UCK6 S282UCK6 8 6kA S281UCK8 S282UCK8 10 6kA S281UCK10 S282UCK10 16 6kA S281UCK16 S282UCK16 20 6kA S281UCK20 S282UCK20 25 6kA S281UCK25 S282UCK25 32 6kA S281UCK32 S282UCK32 40 4.5kA S281UCK40 S282UCK40 50 4.5kA S281UCK50 S282UCK50 63 4.5kA S281UCK63 S282UCK63 Type S280UCZ (2-3 In) BS EN 60947-2. Protection of semiconductor devices and voltage transformer circuits Rated Breaking Single Pole Double Pole Current InA Capacity 0.5 6kA S281UCZ0.5 S282UCZ0.5 0.75 6kA S281UCZ0.75 S282UCZ0.75 1 6kA S281UCZ1 S282UCZ1 1.6 6kA S281UCZ1.6 S282UCZ1.6 2 6kA S281UCZ2 S282UCZ2 3 6kA S281UCZ3 S282UCZ3 4 6kA S281UCZ4 S282UCZ4 6 6kA S281UCZ6 S282UCZ6 8 6kA S281UCZ8 S282UCZ8 10 6kA S281UCZ10 S282UCZ10 16 6kA S281UCZ16 S282UCZ16 20 6kA S281UCZ20 S282UCZ20 25 6kA S281UCZ25 S282UCZ25 32 6kA S281UCZ32 S282UCZ32 40 4.5kA S281UCZ40 S282UCZ40 50 4.5kA S281UCZ50 S282UCZ50 63 4.5kA S281UCZ63 S282UCZ63 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/9 System proM S 260-270-280 series accessories Electrical Auxiliaries and Accessories Description Weight Kg Order Code Auxiliary contact 1 NO + 1 NC 0.040 S2-H11 2 NO 0.040 S2-H20 2 NC 0.040 S2-H02 2 NO + 1 NC 0.050 S2-H21 1 NO + 2 NC 0.050 S2-H12 3 NO 0.050 S2-H30 3 NC 0.050 S2-H03 Signal Contact 0.050 S2-S Signal and changeover Contact 0.050 S2-S/H Undervoltage Release 12V DC 0.070 S2-BM1 24V AC/DC 0.070 S2-BM2 48V AC/DC 0.070 S2-BM3 110V AC/DC 0.070 S2-BM4 220-240V AC / 220V DC 0.070 S2-BM5 380V AC 0.070 S2-BM6 Shunt Trip 12.....60V AC/DC 0.145 S2-A1 110.....415V AC 0.145 S2-A2 110.....250VDC Hand operated neutral 40A Rated Mounted on R/H side of MCB 0.060 S2-NT Padlock device 3mm padlock adapter 0.004 SA1 6mm padlock adapter 0.004 SA1E Padlock with 2 keys 0.02 SA2 Label carrier (set 100 pieces) 0.1 ST Label set (300 pieces) 0.1 ST-E www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/10 System proM S 260-270-280 series Busbars Busbars Cross section length Poles Weight 2 mm mm No. Kg Order Code For single pole MCB’s 12* 988 56 x 1 0.073 SZ-KS1/56 16 1007 56 x 1 0.300 SZ-KS18/56N 36* 988 56 x 1 0.330 SZ-VB45.32 * Uninsulated For double pole MCB’s 16 1035 29 x 2 0.534 SZ-PSB56N 3 For triple pole MCB’s 16 1065 20 x 3 0.700 SZ-PSB12N 6 For four pole MCB’s 16 1058 15 x 4 0.884 SZ-PSB64N 4 Busbars with aux. contact H... or combined signal contact S/H Cross section length Poles Weight 2 mm mm No. Kg Order Code For single pole MCB’s 16 1020 39 x 1 0.283 SZ-KS4/39N For double pole MCB’s 16 1044 24 x 2 0.650 SZ-PSB92N 3 For triple pole MCB’s 16 980 16 x 3 0.632 SZ-PSB52N 3 Insulated end caps Weight Order Code 3 0.001 PSB-END3 4 0.001 PSB-END4 6 0.001 PSB-END6 Cover for unused busbar ways Weight Order Code 5 ways 0.003 SZ-BSK 5 ways SZ`-PSB12N only 0.003 SZ-BSK5 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/11 Protecta Protecta Type B Pan Assemblies Technical Details • Designed and manufactured to BSEN 60439-3 • Rated voltage 400V AC • Busbar rating 250A • Supplied with Earth and Shrouded Neutral Bars 2 • Cable capacity Earth andNeutral Bars 25mm • Finished in RAL7035 TP&N Pan Assemblies No. of outgoing Weight TP&Nways Kg Order Code 4 3.5 EPB304PA 6 4.3 EPB306PA 8 5.1 EPB308PA 12 6.4 EPB312PA 16 8.2 EPB316PA 20 10.2 EPB320PA 24 12 EPB324PA Incomers Description Rating Sensitivity (mA) Order Code 2 35mm terminal block (requires 3) SZ-ESK 2 70mm cable block EPBKIT4 2 120mm cable block EPBKIT3 Switch disconnector 100A 3 pole E273/100rt Switch disconnector 125A 3 pole E273/125rt RCCB 63A 4 pole 30 F364-63/0.03 RCCB 63A 4 pole 100 F364-63/0.1 RCCB 63A 4 pole 300 F364-63/0.3 RCCB time delay 63A 4 pole 300 F394-63/0.3 Non Auto TPMCCB 250A 3 pole 1SDA051327R1 Front cable connection kit for above MCCB (requires 2) 1SDA051482R1 Incomer Connection Kits Description Order Code RCCB connection kit EPBKIT2 Non-auto 250A MCCB connection kit EPBKIT1 - T3 Single phase kit EPBKIT6 Description Order Code Unused way busbar cover (strip of 5) SZ-BSK Not suitable for the S500, S290 and S951 MCB’s For Protecta Final Distribution Boards please refer to: ABB Installer Products Catalogue number 1TXD000001P0201 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/12 Notes www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/13 S500 range High Performance Miniature circuit breakers S500 B,C & D trip curves. BS EN 60898. Ratings 6 to 63A. Description The ever increasing demand for energy is resulting in continually increasing short circuit currents in low voltage electrical networks. This places high demands on the protective switchgear with regard to safety, reliability and breaking capacity. The High Performance MCB S500 satisfies these requirements by virtue of its special technical features. It is provided with a thermal and/or electromagnetic release to protect circuits, motors, equipment and systems from the results of overload and short circuit currents. S 500 Standards EN 60898, IEC 947-2, UL 1077, CE conformity, CAN/CSA-C22.2 N235-M89 Poles 1P, 2P, 3P, 4P Rated current In [A] 6 to 63 Rated voltage Ue [V] 690 Rated breaking capacity Icn [kA] 25 acc. to IEC 898 service Ics [kA] 12.5 Rated breaking capacity ultimate Icu [kA] 50 acc. to IEC 947-2 - 230/400V service Ics [kA] 25 Rated breaking capacity ultimate Icu [kA] 30 acc. to IEC 947-2 - 440V service Ics [kA] 22 Rated breaking capacity ultimate Icu [kA] 15 acc. to IEC 947-2 - 500V service Ics [kA] 11 Rated breaking capacity ultimate Icu [kA] 6 acc. to IEC 947-2 - 690V service Ics [kA] 3 Rated breaking capacity Icc [kA] 30 (up to 25A); 18 (25 to 63 A) acc. to UL 1077 and CSA - 240V Rated breaking capacity Icc [kA] 14 acc. to UL 1077 and CSA - 277/480V Rated breaking capacity Icc [kA] 6 acc. to UL 1077 and CSA - 600V Thermomagnetic release B: 3 In £ Im £ 5 In • characteristics C: 5 In £ Im £ 10 In • D: 10 In £ Im £ 20 In • Reference temperature [ºC] 30ºC Rated frequency 16 2/3 ... 60 Hz Tropicalization DIN 50016 Current limitation at Icc 30 kA Ip < 8000A Total short-circuit breaking time max. 2.5 ms at Icc 30 kA Mechanical life 20000 Protection degree IP20 Ambient temperature (with daily average £+35ºC) [ºC] -25...+55 Mounting on DIN rail EN 50022 (35mm) by means of rapid fixing device Line connection top/bottom 2 Terminal size upper/lower per cable [mm ] 25/25 for further technical details please refer to S500 technical catalogue number 10139/A www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/14 S500 Range High Performance Miniature circuit breakers S500 B,C & D trip curves. BS EN 60898. Ratings 6 to 63A. Type S500B (3-5 In) BS EN 60898. Small inrush or switching surges, heating loads, tungsten lighting. Rated 1-pole 2-pole 3-pole 4-pole Current [A] 6 S501-B6 S502-B6 S503-B6 S504-B6 10 S501-B10 S502-B10 S503-B10 S504-B10 13 S501-B13 S502-B13 S503-B13 S504-B13 16 S501-B16 S502-B16 S503-B16 S504-B16 20 S501-B20 S502-B20 S503-B20 S504-B20 25 S501-B25 S502-B25 S503-B25 S504-B25 32 S501-B32 S502-B32 S503-B32 S504-B32 40 S501-B40 S502-B40 S503-B40 S504-B40 50 S501-B50 S502-B50 S503-B50 S504-B50 63 S501-B63 S502-B63 S503-B63 S504-B63 Type S500C (5-10 In) BS EN 60898. Moderate switching surges for short durations. Rated 1-pole 2-pole 3-pole 4-pole Current [A] 6 S501-C6 S502-C6 S503-C6 S504-C6 10 S501-C10 S502-C10 S503-C10 S504-C10 13 S501-C13 S502-C13 S503-C13 S504-C13 16 S501-C16 S502-C16 S503-C16 S504-C16 20 S501-C20 S502-C20 S503-C20 S504-C20 25 S501-C25 S502-C25 S503-C25 S504-C25 32 S501-C32 S502-C32 S503-C32 S504-C32 40 S501-C40 S502-C40 S503-C40 S504-C40 50 S501-C50 S502-C50 S503-C50 S504-C50 63 S501-C63 S502-C63 S503-C63 S504-C63 Type S500D (10-14 In) BS EN 60898. High inrush applications. Rated 1-pole 2-pole 3-pole 4-pole Current [A] 10 S501-D10 S502-D10 S503-D10 S504-D10 13 S501-D13 S502-D13 S503-D13 S504-D13 16 S501-D16 S502-D16 S503-D16 S504-D16 20 S501-D20 S502-D20 S503-D20 S504-D20 25 S501-D25 S502-D25 S503-D25 S504-D25 32 S501-D32 S502-D32 S503-D32 S504-D32 40 S501-D40 S502-D40 S503-D40 S504-D40 50 S501-D50 S502-D50 S503-D50 S504-D50 63 S501-D63 S502-D63 S503-D63 S504-D63 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/15 S500K Range High Performance Miniature Circuit Breakers S500 K trip curve. BS EN 60947. Ratings 0.15 to 45A. Type S500K (8-14 In) BS EN 60947. Protection of motors, transformers lamps and cable. Adjustment Range (A) 1-pole 2-pole 3-pole 0.1 - 0.15 S501K0.15 S502K0.15 S503K0.15 0.14 - 0.21 S501K0.21 S502K0.21 S503K0.21 0.2 - 0.3 S501K0.3 S502K0.3 S503K0.3 0.28 - 0.42 S501K0.42 S502K0.42 S503K0.42 0.38 - 0.58 S501K0.58 S502K0.58 S503K0.58 0.53 - 0.8 S501K0.8 S502K0.8 S503K0.8 0.73 - 1.1 S501K1.1 S502K1.1 S503K1.1 1 - 1.5 S501K1.5 S502K01.5 S503K1.5 1.4 - 2.1 S501K2.1 S502K2.1 S503K2.1 2 - 3 S501K3 S502K3 S503K3 2.8 - 4.2 S501K4.2 S502K4.2 S503K4.2 3.8 - 5.8 S501K5.8 S502K5.8 S503K5.8 5.3 - 8 S501K8 S502K8 S503K8 7.3 - 11 S501K11 S502K11 S503K11 10 - 15 S501K15 S502K15 S503K15 14 - 20 S501K20 S502K20 S503K20 18 - 26 S501K26 S502K26 S503K26 23 - 32 S501K32 S502K32 S503K32 29 - 37 S501K37 S502K37 S503K37 34 - 41 S501K41 S502K41 S503K41 28 - 45 S501K45 S502K45 S503K45 Accessories Description Order Code Auxiliary contact 1no/1nc S500-H11 Auxiliary contact 2no S500-H20 Signal contact 1no/1nc S500-S11 Signal contact 2no S500-S20 Padlock adaptor S500-SA Rotary drive 1 to 3 pole S500-RD3 Rotary drive 4 to 6 pole S500-RD4 Undervoltage release 24, 110, 230, 400V AC UA * Undervoltage release 24, 110, 230, 400VDC UA * Shunt trip 24, 110, 230, 400V AC/DC AL * *When ordering shunt or undervoltage trips please add suffix and voltage to the S500 reference number as these devices have to be factory fitted. For starter co-ordination tables please request S500 catalogue 10107/B www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/17 System proM Single pole & Switched Neutral Miniature circuit breakers S951N. C trip curves. BS EN 60898. Ratings 2 to 40A. Description SPSN Miniature Circuit Breakers in a single module width. Ideal for applications where regulations require the neutral to be switched such as Petrol Stations and Caravan Sites etc. Technical Details • Current ratings 2 to 40 A at 30 degrees C to BS EN 60898 • Rated voltage 230V AC • Maximum operating voltage 250VAC. • Minimum operating voltage 12 VAC/DC • Breaking capacity: BS EN 60898 - 6kA. • Space saving • All poles disconnected in event of a fault • Mechanical service life: 20,000 operations. 2 • Cable capacity: 16mm upper and lower terminals. • Weight: 110g • Ambient temperature: -25 to +55ºC Type S951NC (5-10 In) BS EN 60898. Single pole & switched neutral miniature circuit breakers Current (A) Weight (kg) Order Code 2 0.110 S951NC2 4 0.110 S951NC4 6 0.110 S951NC6 10 0.110 S951NC10 16 0.110 S951NC16 20 0.110 S951NC20 25 0.110 S951NC25 32 0.110 S951NC32 40 0.110 S951NC40 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/18 System proM Residual Current Devices BSEN 61008 Ratings 16 to 100A. Description • ABB residual current devices have a measuring system consisting of a summation transformer with a permanent magnet trippng device, operating without the need of an auxiliary supply, to open a circuit automatically if an earth leakage fault occurs between phase and earth greater or equal to its rated sensitivity in mA. • Provision of earth leakage, switching and isolation functionality to electrical circuits. • Same form and design as the S2 MCB range, allowing easy interconnection with busbar blocks and common mounting in distribution panels. • Suitable for symmetrical DIN rail or panel mounting. Technical Data • Specification to BSEN 61008: F360, F660 Class AC, F370 and F390 Class A • Rated Voltage: Two pole 230V AC, Four pole 230/400V AC. • Maximum operating voltage: Rated voltage + 10%. • Test button range: 100V AC up to 264VAC • Frequency: 50 to 60 Hz. 2 2 • Cable capacity: 25mm up to 63A, 50mm for 80 and 100A • Life expectancy: at least 5,000 operations. • Maximum tightening torque: 3Nm. • Ambient temperature: -25ºC to +55ºC • Maximum weights: 2pole 0.365kg, 4 pole 0.49kg. • Dimensions: see page 3-46 Two Pole F362 & F662. Class AC. Current (A) Sensitivity 10mA 30mA 100mA 300mA 16 F362-16/0.01 - - - 25 - F362-25/0.03 F362-25/0.1 F362-25/0.3 40 - F362-40/0.03 F362-40/0.1 F362-40/0.3 63 - F362-63/0.03 F362-63/0.1 F362-63/0.3 80 - F662-80/0.03 F662-80/0.1 F662-80/0.3 100 - F662-100/0.03 F662-100/0.1 F662-100/0.3 Four Pole F364 & F664. Class AC. Current (A) Sensitivity 30mA 100mA 300mA 25 F364-25/0.03 F364-25/0.1 F364-25/0.3 40 F364-40/0.03 F364-40/0.1 F364-40/0.3 63 F364-63/0.03 F364-63/0.1 F364-63/0.3 80 F664-80/0.03 F664-80/0.1 F664-80/0.3 100 F664-100/0.03 F664-100/0.1 F664-100/0.3 Two Pole F372 & F392. Class A (pulsating DC sensitive) Current (A) Sensitivity 30mA 100mA 300mA 25 F372-25/0.03 F372-25/0.1 F372-25/0.3 40 F372-40/0.03 F372-40/0.1 F372-40/0.3 63 F372-63/0.03 F372-63/0.1 F372-63/0.3 63 time delayed - - F392-63/0.3 Four Pole F374 & F394. Class A (pulsating DC sensitive) Current (A) Sensitivity 30mA 100mA 300mA 25 F374-25/0.03 F374-25/0.1 F374-25/0.3 40 F374-40/0.03 F374-40/0.1 F374-40/0.3 63 F374-63/0.03 F374-63/0.1 F374-63/0.3 63 time delayed - F394-63/0.1 F394-63/0.3 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/19 System proM Add on Residual Current Blocks DDA60 series Ratings to 63A. BSEN 61009 when connected to MCB Application DDA60 blocks attach to the right hand side of any multipole S260, S270 or S280 MCB to form an RCBO in compliance to BS EN 61009. This standard defines that it shall be possible to assemble the RCBO on site only once, and that any subsequent disassembly shall leave permanent visible damage. The assembly of the block provides a high level of earth fault protection in addition to the short circuit and overload protection provided by the MCB to which it is coupled. The assembled RCBO is suitable for mounting on DINrail or into a wide range of DIN enclosures. Technical Data • Standard BS EN 61009 when coupled to an MCB. Class AC device. • Rated voltage 230 - 400V AC. • Maximum operating voltage 440V AC. • Minimum operating voltage 195V AC. • Frequency 50/60Hz • Mechanical life: 20,000 operations. 2 • Cable capacity: 25mm up to 63A • Weight: two pole 0.21g, three pole 0.27g, four pole 0.33g. DDA60 blocks. BS EN 61009. Residual current blocks Current (A) Sensitivity 30mA 100mA 300mA Two Pole 63A DDA62-63/0.03 DDA62-63/0.1 DDA62-63/0.3 Three Pole 63A DDA63-63/0.03 - DDA63-63/0.3 Four Pole 63A DDA64-63/0.03 - DDA64-63/0.3 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/20 System proM Single pole and Solid Neutral RCBO DS271 series Ratings 6 to 32A. BS EN 61009-2-2. Class AC Application To provide protection against earth leakage faults, short circuits and overloads in residential, commercial and industrial electrical distribution systems. Suitable for installation on DIN rail, Housemaster Consumer Units and Protecta Final Distribution Boards and Pan Assemblies. Technical Data • BS EN 61009-2-2 Class AC device. • Current ratings 6 to 32A. • Rated voltage 230V AC. • Breaking capacity 10kA to BSEN 60898 • Maximum service voltage 253VAC. • Minimum service voltage 195V AC. • Service life at least 5,000 switching cycles. • Lockable in On or Off position. • Supplied with 800mm flying neutral and funtional earth leads. 2 • Outgoing cable size 10mm • Weight 0.125g DS271 blocks. BS EN 61009. Single module width RCBO 17.5mm Current (A) Sensitivity Type B Type C (3-5 In) (5-10 In) 6 30mA DS271AC-B6/0.03 DS271AC-C6/0.03 10 30mA DS271AC-B10/0.03 DS271AC-C10/0.03 16 30mA DS271AC-B16/0.03 DS271AC-C16/0.03 20 30mA DS271AC-B20/0.03 DS271AC-C20/0.03 25 30mA DS271AC-B25/0.03 DS271AC-C25/0.03 32 30mA DS271AC-B32/0.03 DS271AC-C32/0.03 Devices of 10mA sensitivity available on request. www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/21 System proM Single pole and switched neutral RCBO DS651 & DS671 series Ratings 6 to 40A. BS EN 61009 Application To provide protection against earth leakage faults, short circuits and overloads in residential, commercial and industrial electrical distribution systems. Ideal for applications where regulations require the neutral to be switched such as Petrol Stations and Caravan Sites etc. Suitable for mounting on DIN rail, in ABB Protecta Distribution Boards or in a wide range of DIN enclosures Technical Data • BSEN 61009. Class AC devices • Current ratings 6 to 40A. • Rated voltage 230/400V AC • Breaking capacity: DS651 - 6kA, DS671 - 10kA to BS EN 61009. • Maximum service voltage 440V AC. • Minimum operating voltage 110VAC. • Frequency 50 / 60 Hz • Life expectancy 10,000 electrical and 20,000 mechanical operations. • Lockable in On or Off position. • Weight 0.280g • DS651 and DS671 RCBO are compatible with the S2 family accessories i.e. auxiliary contacts, shunt trips, signal contacts etc. see page 3/10 DS651 & DS671 RCBO. BS EN 61009. Type C Curve (5-10 In) Current (A) Sensitivity 6 kA 10 kA 6 30mA DS651C6/0.03 DS671C6/0.03 10 30mA DS651C10/0.03 DS671C10/0.03 16 30mA DS651C16/0.03 DS671C16/0.03 20 30mA DS651C20/0.03 DS671C20/0.03 25 30mA DS651C25/0.03 DS671C25/0.03 32 30mA DS651C32/0.03 DS671C32/0.03 40 30mA DS651C40/0.03 16 10mA DS651C16/0.01 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/22 System proM RD2 residual current monitors Application Residual current monitors (RCMS) with external transformer can detect leakage currents. Through minidips you can set sensitivity and time delay. Technical Characteristics Standard IEC62020 Operating voltage [V] 110 to 400a.c.; 48 to 110d.c. Frequency [Hz] 50 to 60 Sensitivity settings [IDn] 0.03; 0.1; 0.3; 0.5; 1; 2A Time delay [s] 0.05 (fast); 0.3; 0.5; 1; 2; 5 settings Contact capacity [A] 10 at 250V a.c. (ohmic) Contact type change over Operating temperature [ºC] -5...+40 Power consumption [W] 0.8 at 110V a.c.; 1.8 at 230V a.c.; 6.8 at 400V a.c. 0.2 at 48V d.c.; 1 at 110V d.c. Number of modules [No] 2 Description Order Code Residual current monitor RD2 Toroidal transformer Ş 35mm TR35 Toroidal transformer Ş 60mm TR60 Toroidal transformer Ş 80mm TR80 Toroidal transformer Ş 110mm TR110 Toroidal transformer Ş 210mm TR210 Toroidal transformer Ş 210mm (opening version) TR210/A Modular toroidal transformer Ş 29mm TRM www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/23 System proM E 240 - E 270 switch disconnectors Technical Details Rated Voltage U [V] a.c. 230/400 Rated current I [A] 63....125 Rated frequency [Hz] 50/60 Rated short-time [A] 20 times In x 1 second withstand current Utilization category AC22 (E240); AC23 (E270, 63....100A) AC22 (E270, 125A) Modules [No] 2, 3, 4 Standards BS EN 60947-3 Approvals E272-4 63A: VDE, SEV; E273 63A: VDE, SEV, DEMKO. Order Code Double Pole switch disconnectors 63A Rated current (2 module) E242/63rt 100A rated current (2 module) E272/100rt 125A rated current (2 module) E272/125rt Triple Pole switch disconnectors 63A Rated current (3 module) E243/63rt 100A rated current (3 module) E273/100rt 125A rated current (3 module) E273/125rt Four Pole switch disconnectors 63A Rated current (4 module) E244/63rt 100A rated current (4 module) E274/100rt 125A rated current (4 module) E274/125rt www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/24 System proM Installation Contactor ESB series Ratings to 63A. ESB series contactors For loads to be automatically controlled through high number of operations; i.e. building automation, controlling of small pumps, ventilations, heating systems, lighting systems, and so on. This series consists of various models differing in the number of contacts, rated current and control circuit voltage. Technical Data ESB 20 ESB24 ESB40 ESB63 n Rated Voltage U 230VAC 400VAC 400V AC 400VAC n Rated current I in AC1 20A 24A 40A 63A Rated power in AC3 230V 1.3kW 2.2kW 5.5kW 8.5kW 400V - 4kW 11kW 15kW Rated frequency 50/60Hz 40/450Hz 40/450Hz 40/450Hz Control circuit voltage (V) a.c. 24, 110, 230 a.c./d.c. 24, 230 a.c./d.c. 24, 230 a.c./d.c. 24, 230 Electrical operations 1 million 1 million 1 million 1 million Mechanical operations in AC1 150,000 130,000 150,000 150,000 in AC3 150,000 500,000 170,000 240,000 Power consumption 1W per pole 1.2W per pole 3W per pole 6W per pole Modules 1 2 3 3 Standards IEC60947-4-1 IEC 60947-4-1 IEC60947-4-1 IEC 60947-4-1 IEC 61095 IEC 61095 IEC 61095 IEC 61095 ESB 20 (20A) Contactors. Order Code Control circuit voltage 24V a.c. - 1NO + 1NC contacts ESB20-11/24 Control circuit voltage 110V a.c. - 1NO + 1NC contacts ESB20-11/110 Control circuit voltage 230V a.c. - 1NO + 1NC contacts ESB20-11/230 Control circuit voltage 110V a.c. - 2NC contacts ESB 20-02/110 Control circuit voltage 230V a.c. - 2NC contacts ESB 20-02/230 Control circuit voltage 24V a.c. - 2NO contacts ESB 20-20/24 Control circuit voltage 110V a.c. - 2NO contacts ESB 20-20/110 Control circuit voltage 230V a.c. - 2NO contacts ESB 20-20/230 ESB 24 (24A) Contactors. Order Code Control circuit voltage 24V a.c./d.c. - 4NO contacts ESB24-40/24 Control circuit voltage 230V a.c./d.c. - 4NO contacts ESB24-40/230 ESB 40 (40A) Contactors. Order Code Control circuit voltage 24V a.c./d.c. - 4NO contacts ESB40-40/24 Control circuit voltage 230V a.c./d.c. - 4NO contacts ESB40-40/230 ESB 63 (63A) Contactors. Order Code Control circuit voltage 24V a.c./d.c. - 4NO contacts ESB63-40/24 Control circuit voltage 230V a.c./d.c. - 4NO contacts ESB63-40/230 Auxiliary Elements / Accessories Available for ESB 24/40/63 Order Code 2NO contacts EH04-20 1NO + 1NC contacts EH04-11 Spacer ESB-DIS Terminal Covers for ESB 24 ESB-PLK 24 Terminal Covers for ESB 40/63 ESB-PLK 40/63 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/25 System proM Latching relays E250 series Ratings to 16A. Application Electro-magnetic latching relays allow contact switching for each impulse sent to coil using normally open pushbuttons. Ideal for lamp controlling from different positions, they are available in various versions according to pick-up voltage and to contact positions. They also allow manual operation on the product and contact position indicator (visual on the product). Technical Data Rated Voltage Un [V] a.c. 400 / 250 Rated Current In [A] 10 / 16 Rated Frequency [Hz] 50 / 60 Contact Capacity [W] 2300 (incandescent lamps) 1300 (power factor uncorrected fluorescent lamps cosj=0.6) 500 (power factor corrected fluorescent lamps in parallel) Minimum value of control impulse [mA] 50 Circuit voltage [V] 8, 12, 24, 230 Electric operations [No] 100,000 Mechanic operations [No] 1 million Power consumption [W] 2 (1 and 2 contacts); Modules [No] 1 Standards IEC/EN 60669-2 Approvals DEMKO, NEMKO, SEMKO, SEV, FI E250 latching relays. With 1 and 2 contacts Description Order Code relay with 1 contact - 8V a.c. E251-8V relay with 1 contact - 12V a.c. E251-12V relay with 1 contact - 24V a.c. E251-24V relay with 1 contact - 230V a.c. E251-230V relay with 2 contacts - 8V a.c. E252-8V relay with 2 contacts - 12V a.c. E252-12V relay with 2 contacts - 24V a.c. E252-24V relay with 2 contacts - 230V a.c. E252-230V relay with 1NC + 1NO contact - 8V a.c. E256-8V relay with 1NC + 1NO contact - 12V a.c. E256-12V relay with 1NC + 1NO contact - 24V a.c. E256-24V relay with 1NC + 1NO contact - 230V a.c. E256-230V relay with 2 sequential contact - 8V a.c. E255-8V relay with 2 sequential contact - 12V a.c. E255-12V relay with 2 sequential contact - 24V a.c. E255-24V relay with 2 sequential contact - 230V a.c. E255-230V www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/26 System proM Pushbuttons and indicator lamps E220 series Ratings to 16A. Application The pushbuttons are used for remote control in every kind of electrical installation (public, tertiary, industrial). The indicator lamps signal any event in every kind of electric installation (public, tertiary, industrial). Technical Data Rated voltage Un [V] a.c. 250 Rated current I n [A] 16 Rated frequency [Hz] 50 / 60 Power consumption [W] 0.96 ... 1.50 Modules [No] 1 Standards IEC/EN 60669-1 IEC/EN 60947-5-1 E225 pushbuttons. Description Order Code Grey pushbutton with contacts 1NO + 1NC E225-11B Red pushbutton with contacts 1NO + 1NC E225-11C Green pushbutton with contacts 1NO + 1NC E225-11D Yellow pushbutton with contacts 1NO + 1NC E225-11E Black pushbutton with contacts 1NO + 1NC E225-11F Blue pushbutton with contacts 1NO + 1NC E225-11G E227 Illuminated pushbuttons. Description Order Code Transparent illuminated pushbutton with contacts 1NO + 1NC E227-11B Red illuminated pushbutton with contacts 1NO + 1NC E227-11C Green illuminated pushbutton with contacts 1NO + 1NC E227-11D Yellow illuminated pushbutton with contacts 1NO + 1NC E227-11E Blue illuminated pushbutton with contacts 1NO + 1NC E227-11G E229 Indicator lamps. Description Order Code Transparent indicator lamp with 220V a.c. bulb E229-B Red indicator lamp with 220V a.c. bulb E229-C Green indicator lamp with 220V a.c. bulb E229-D Yellow indicator lamp with 220V a.c. bulb E229-E Blue indicator lamp with 220V a.c. bulb E229-G www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/27 System proM Time switches ETS & DTS series Application To control circuit opening and closing according to scheduled planning. The time switches can be set on permanent ON-OFF, available both daily and weekly programmes. Suitable for mounting on DINrail, in ABB Housemaster Consumer unit or DINenclosures. ETS Time switches. Electro-Mechanical Description Order Code daily programme without standby battery - 3 modules ETS-1 daily programme with standby battery (200h) - 3 modules ETS-1/R weekly programme with standby battery (200h) - 3 modules ETS-7/R Technical Data Rated Voltage Un [V] a.c. 230 +/- 10% n Rated contact capacity I [A] 16 cosj=1 4 cosj=0.6 Rated frequency [Hz] 50 / 60 Min. spread between two commands 15 min (daily programme) 2 hours (weekly programme) Max. number of command per cycle [No] 96 (daily programme) 84 (weekly programme) Operating accuracy 1s / 24h Life cycle [No] 10 years or 50,000 insertions Operating temperature [ºC] -10...+45 Power consumption [W] 0.5 Modules [No] 1-3 Standards IEC 60669-1, EN 60730-1 Application The range includes single/multichannel daily/weekly programme switches. These are functionally more sophisticated and control several loads or independent groups of loads requiring different time controls with an unique time reference. The EEPROM memory of DTS series devices eliminates the risk of erasing configured programme, regardless the duration of any voltage failure. DTS Time switches. Digital time switches Description Order Code daily programme time switch with standby battery (3years), 1 channel DTS 1/1 daily/weekly programme time switch with standby battery (3years), 1 channel DTS 7/1 daily/weekly programme time switch with standby battery (3years), 2 channels DTS 7/2 daily/weekly programme time switch with standby battery (3years), DTS 7/2 I 2 channels + pulse output daily/weekly programme time switch with standby battery (150h), 3 channels DTS 7/3 Technical Data Rated Voltage Un [V] a.c. 230 Rated contact capacity In [A] 16 cosj=1 2.5 cosj=0.6 Rated frequency [Hz] 50 / 60 Operating accuracy ±2.5s / 24h Max. Switching [Frº] 12 (daily programme - 1 channel) 28 (weekly programme - 1 channel) 42 (weekly programme - 2 channels) 322 (daily/weekly programme - 3 channels) Power consumption [W] 5 Modules [No] 2, 6 (3 channels) Standards IEC/EN 60730-1 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/28 System proM Power failure signalling lamps LE Application The built-in battery allows the charging of the lamp when the device is connected to network voltage. It automatically switches on when the voltage fails allowing an easy and safe operation within the consumer unit or the switchboard it is installed in. A green led signals the standard operation and a red led indicates the device OFF for battery saving. Technical Characteristics Rated voltage Un [V] a.c. 230 Rated Frequency [Hz] 50/60 Power consumption [W] 10 Number of modules [No] 2 Max. recharge cycles [No] 500 Indications Green led = standard operation Red led = lamp OFF Standby battery [min] 45 Lighting level [Iumen] 20 LE Power failure signalling lamp. Description Order Code Power failure signalling lamp LE-230 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/29 System proM Bell transformers TM series Application These transformers are for feeding bells (discontinuous use) and have very low secondary safety voltage. Technical Characteristics Standards EN 61558-1/2-8 Primary Rated voltage Un [V] a.c. 230 Secondary Rated voltage Un [V] 4, 8, 12, 24 Rated Frequency [Hz] 50 Power consumption [VA] 8, 10, 15, 16, 24, 30, 40 (discontinuous service) Power consumption [W] 1...4 Number of modules [No] 2, 3 TM Bell transformers. Description Order Code sec. 4-8-12V (10VA discontinuous) TM10/12 sec. 12-24V (10VA discontinuous) TM10/24 sec. 4-8-12V (15VA discontinuous) TM15/12 sec. 12-24V (15VA discontinuous) TM15/24 sec. 4-8-12V (30VA discontinuous) TM30/12 sec. 12-24V (30VA discontinuous) TM30/24 sec. 4-8-12V (40VA discontinuous) TM40/12 sec. 12-24V (40VA discontinuous) TM40/24 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/30 System proM Twilight switches TWS-1 series Application To switch-on and/or switch-off operating illuminating devices at preset level of ambient lighting. Used in combination with sensor detecting if lighting level is higher or lower than preset threshold. Technical Characteristics Standards IEC 60669-1, EN 61000-3-2 Rated voltage Un [V] a.c. 230 Rated contact capacity In [A] 16 (ohmic) 25 (inductive load cos=0.6) [W] 1000 (power factor corrected fluorescent lamps) Rated Frequency [Hz] 50/60 Adjustment range [Lux] 2...300 Hysteresis [%] 1.3 (of present value) Delay [s] Switch-on +50 Switch-off +50 Max. distance between [m] 100 twilight switch and sensor Twilight switch [ºC] -20...+55 operating time Sensor operating time [ºC] -30...+70 Power consumption [W] 5 Number of modules [No] 2 TWS Twilight switches. Description Order Code Twilight switch with sensor TWS-1 Sensor (as spare part) LS-1 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/31 Smissline Smissline The Trick with the Click The Idea Devices are simply plugged onto the system without the need 5 state-of-the-art protection devices of identical design are simply Combination Module for any auxiliary adapters. Correction and expansion work Various Power Supply Options plugged onto a busbar system. couldn’t be easier. Using a combination module, you can configure a variety of You can supply power, for example, via a residual current circuit- devices. For instance a motor protection circuit-breaker together No need for an elaborate power supply and connection work. breaker. The busbars can be interrupted by means of isolators so that with a contactor can be arranged to form one single unit. residual current devices can be configured in groups. In addition to the saving in time and costs, a further advantage of the system is that it permits fast and easy replacement of the devices. If corresponding spare capacity is planned, subsequent expansion is achieved by simply plugging the additional devices onto the busbar 3 3 Freedom in Concept and Arrangement Smissline gives you freedom of choice: Mixed-pole arrangements are accomodated with ease. Vertical Equipment Layout With a vertical layout you can save even more space as this arragement renders outgoing terminaols unnecessary. The outgoing cable are connected directly to the devices. Signalling Signal and auxiliary contacts are available for all devices. They can be powered directly by the use of two auxiliary busbars within the socket base. Shock-hazard Protection Compact Design All busbars can be covered with shock-hazard protection Smissline saves space while providing effective shock-hazard covers. This makes the entire system touch-proof. proection. With the outer N-terminal acting as the isolator, a single-pole outgoing circuit L/N/PE up to 32A requires an overall width of just 18mm. Flexible, Fast, Ideal Any changes in configuration are carried out quickly, and additional devices are simply plugged on for expansion. DIN Rail Products Thanks to the DIN rail adapter, a variety of devices can be integrated into the system. ABB LIMITED 3/32 ABB LIMITED 3/33 Smissline Fields of Application: Advantages and Benefits ABB Smissline flexible distribution system The ABB Smissline system is a unique concept allowing maximum flexibility in a “plug-in” final distribution system. The assembly consists of a base and busbar system onto which can be “plugged” MCB’s, RCD’s, RCBO’s and Isolators with a complete range of add-on accessories. For full technical details please request the Smissline catalogue 20165/C, or ask for an ABB sales engineer to demonstrate the Smissline benefits to you. Industrial Buildings • High Degree of system availability • Combination module as complete motor starter unit • Clear allocation of devices and terminals Telecommunications • Interchangeability of devices • Overvoltage-protected systems • Specifically targeted device and circuit protection Shopping Centres • Quick change configuration • Clearly arranged RC protection structure • Mixed-pole devices can be placed in any position EDP and Radio Installations • Central installation monitoring • Flexible adaptation to building requirements • Permanent current availability www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/34 Smissline Fields of Application: Advantages and Benefits Airports • High Degree of system availability • Short realization time • Cost-effective adaptation Hospitals, Clinics • High Degree of safety and reliability for maintenance/service • Residual current signalling device for monitoring • Permanent current availability Banks, Insurance Companies • Various power supply options • Clearly arranged RC protection structure • System modifications can be carried out quickly Office Buildings • Flexibility in lighting and air conditioning systems • Expansion options • Flexibility for system modifications Traffic • Short time delayed residual current circuit-breakers for long cables • Overvoltage-protection system • Fast replacement of combination module as complete motor starter unit www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/35 Surge Protection Optical Monitoring Block Surge Protection Surge Protection Electrotechnical Electrical equipment Sensitive electronic Highly sensitive equipment containing little equipment electronic sensitive electronics equipment Type of equipment to be protected Protection Level from from from from up 1.8 to 2.5kV 1.5 to 1.8kV 1 to 1.5kV 0.5 to 1 kV Determine Exposure Level 2 The Exposure level is defined by the number of lightning strikes per km (Ng) in the concerned area or by the keraunic level (Nk) of this zone (how many times thunder is heard in one year). Ng and/or Nk are data that regional meteorlogical offices can give you. The mean Nk value for Europe is 25. Empirically, one can estimate the Ng = 0.10 x Nk, i.e. a mean Ng value of 2.50 for Europe. Refer to the following tables for product selection Characteristics BOS 230 For use on 230/400V networks single phase Max. number of 17.7mm modules monitored/Type of arresters 15 / PU - PM Emitter current consumption at 230V in watch state < 10mA Reciever current consumption at 230V in watch state < 10mA Teleindication contact data SPDT - min. volage / min. current 6V DC / 10mA - max. voltage (50Hz) / max. current (50Hz) 250V / 5A Optical link visualization LED on emitter and reciever Fault Visualisation (one of the arresters reserved or disconnected) red indication on reciever 2 Terminal wire capacity 2.5mm solid Recommended circuit-breaking device 2A fuse Operating temperature -20°C to +40°C Storage temperature -40°C to +70°C Selection Body Colour Type Order Code Grey OVR S1GN 2CTB813815R0000 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/36 Surge Protection Single-pole lightning arresters 15kA Equipment Type Up Value of the equipment to be protected (in US $) Slightly Exposed 2,000 20,000 Area: Imax 15kA Electrotechnical 2.5 kV optional Ng £ 0.5 Electronic 1.8 kV little sensitive Electronic 1.0 kV recommended sensitive Electronic 0.5 kV highly sensitive Characteristics For use on IT or TN-C networks 230V / 400V Max discharge current (once) 8/20 wave form 15kA Max. continuous operating voltage Uc 250V / 440V Nominal discharge current (20 times) 8/20 wave 5kA Protection level Up 1.2kV / 1.8kV Internal short circuit withstand current Icc 10kA Continuous operating current < 1mA Follow current none Built-in thermal disconnection yes Reserve system none Visualization of arrester status yes 2 2 Terminal wire jauge (stranded/solid) Ph/N: 16/25mm - Ground 35/50mm Operating temperature -20°C to +40°C Storage temperature -40°C to +70°C Selection Surge Protection Single-pole Body Colour Information Type Order Code lightning arresters White Single-pole lightning arresters non pluggable OVR 15-440 2CTB813811R0400 15kA White Single-pole lightning arresters OVR 15-440P 2CTB813851R1200 White Single-pole lightning arresters remote control OVR 15-440PTS 2CTB813851R0600 White Replacement cartridges OVR 15-440C 2CTB813854R0600 Selection Surge Protection Double-pole Body Colour Information Type Order Code lightning arresters White Double-pole lightning arresters non pluggable OVRNI 15-275 2CTB813812R0400 15kA White Double-pole lightning arresters OVRNI 15-275P 2CTB813852R1200 White Double-pole lightning arresters remote control OVRNI 15-275PTS 2CTB813852R0600 White Replacement cartridges OVRNI 15-275C 2CTB813854R1200 White Neutral cartridges OVRNI 15-275NC 2CTB813854R0000 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/37 Surge Protection 15kA Lightning Arresters Selection Surge Protection Four-pole Body Colour Information Type Order Code lightning arresters White Four-pole lightning arresters non pluggable OVRN3-15-275 2CTB813813R0400 15kA White Four-pole lightning arresters pluggable OVRN3-15-275P 2CTB813853R1200 White Four-pole lightning arresters remote control OVRN3-15-275PTS 2CTB813853R0600 White Replacement cartridges OVR 15-275C 2CTB813854R1200 White Neutral cartridges OVR 65NC 2CTB813854R0000 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/38 Surge Protection 40kA Protection Information Equipment Type Up Value of the equipment to be protected (in US $) 2,000 20,000 Exposed Electrotechnical 2.5 kV optional Area: Electronic Imax 40kA 1.8 kV recommended little sensitive 0.5 < Ng £ 1 Electronic 1.0 kV sensitive Electronic 0.5 kV highly highly sensitive Equipment Type Up Value of the equipment to be protected (in US $) 2,000 20,000 Exposed to Electrotechnical 2.5 kV recommended very exposed Area: Electronic 1.8 kV Imax 40kA little sensitive 1 < Ng £ 1.3 Electronic Imax 65kA 1.0 kV highly sensitive 1.3 < Ng £ 1.5 Electronic 0.5 kV highly sensitive Characteristics For use on IT or TN-C networks 230V / 400V Max discharge current (once) 8/20 wave form 40kA Max. continuous operating voltage Uc 250V / 440V Nominal discharge current (20 times) 8/20 wave 15kA Protection level Up 1.2kV (multipole) Internal short circuit withstand current Icc 25kA Continuous operating current < 1mA Follow current none Built-in thermal disconnection yes Reserve system none Visualization of arrester status yes 2 Terminal wire jauge (stranded/solid) 16/25mm Operating temperature -20°C to +40°C Storage temperature -40°C to +70°C www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/39 Surge Protection 40kA Lightning Arresters Surge Protection Selection Single-pole lightning arresters Body Colour Information Type Order Code 40kA White Single-pole lightning arresters non pluggable OVR 40-440 2CTB813811R0300 White Single-pole lightning arresters pluggable OVR 40-440P 2CTB813851R1100 White Single-pole lightning arresters remote control OVR 40-440PTS 2CTB813851R0500 White Replacement cartridges OVR 40-440C 2CTB813854R0400 Selection Surge Protection Double-pole Body Colour Information Type Order Code lightning arresters White Double-pole lightning arresters non pluggable OVRNI-40-275 2CTB813812R0300 40kA White Double-pole lightning arresters pluggable OVRNI-40-275P 2CTB813852R1100 White Double-pole lightning arresters remote control OVRNI-40-275PTS 2CTB813852R0500 White Replacement cartridges OVR40-275C 2CTB813854R1000 White Neutral cartridges OVR 65NC 2CTB813854R0000 Selection Surge Protection Four-pole Body Colour Information Type Order Code lightning arresters White Four-pole lightning arresters non pluggable OVRN3-40-275 2CTB813813R0300 40kA White Four-pole lightning arresters pluggable OVRN3-40-275P 2CTB813853R1100 White Four-pole lightning arresters remote control OVRN3-40-275PTS 2CTB813853R0500 White Replacement cartridges OVR40-275C 2CTB813854R1000 White Neutral cartridges OVR 65NC 2CTB813854R0000 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/40 Surge Protection 65kA Protection Information Equipment Type Up Value of the equipment to be protected (in US $) 2,000 20,000 Highly Electrotechnical 2.5 kV recommended Exposed Electronic Area: 1.8 kV little sensitive Imax 65kA 1.5 < Ng £ 2 Electronic 1.0 kV highly sensitive Electronic 0.5 kV highly sensitive Equipment Type Up Value of the equipment to be protected (in US $) 2,000 20,000 Highly Exposed Electrotechnical 2.5 kV recommended Area: Maximum Risk Electronic 1.8 kV Imax 65kA little sensitive 2 < Ng £ 2.5 Electronic 1.0 kV highly sensitive Electronic 0.5 kV highly sensitive Characteristics For use on IT or TN-C networks 230V / 400V Max discharge current (once) 8/20 wave form 65kA Max. continuous operating voltage Uc 250V / 440V Nominal discharge current (20 times) 8/20 wave 20kA Protection level Up 1.5kV: 2kV Internal short circuit withstand current Icc 25kA Continuous operating current < 1mA Follow current none Built-in thermal disconnection yes Reserve system yes Visualization of arrester status yes 2 2 Terminal wire jauge (stranded/solid) Ph/N:16/25mm - Ground 35/50mm Operating temperature -20°C to +40°C Storage temperature -40°C to +70°C www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/41 Surge Protection 65kA Lightning Arresters Surge Protection Selection Single-pole lightning arresters Body Colour Information Type Order Code 65kA White Single-pole lightning arresters non pluggable OVR 65-440S 2CTB813811R0100 White Single-pole lightning arresters OVR 65-440SP 2CTB813851R0700 White Single-pole lightning arresters remote control OVR 65-440SPTS 2CTB813851R0100 White Replacement cartridges OVR 65-440SC 2CTB813854R0100 Selection Surge Protection Double-pole Body Colour Information Type Order Code lightning arresters White Double-pole lightning arresters non pluggable OVRNI-65-440S 2CTB813812R0100 65kA White Double-pole lightning arresters OVRNI-65-275SP 2CTB813852R0700 White Double-pole lightning arresters remote control OVRNI-65-275SPTS 2CTB813852R0100 White Replacement cartridges OVR-65-275SC 2CTB813854R0700 White Neutral cartridges OVR-65NC 2CTB813854R0000 Selection Surge Protection Four-pole Body Colour Information Type Order Code lightning arresters White Four-pole lightning arresters non pluggable OVRN3-65-440S 2CTB813813R0100 65kA White Four-pole lightning arresters OVRN3-65-275SP 2CTB813853R0700 White Four-pole lightning arresters remote control OVRN3-65-275-SPTS 2CTB813853R0100 White Replacement cartridges OVR-65-275SC 2CTB813854R0700 White Neutral cartridges OVR-65NC 2CTB813854R0000 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/42 Notes www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/43 Technical Details Tripping Curves Tripping characteristic B C D Standard IEC/EN 60898 IEC/EN 60898 IEC/EN 60898 Rated current In 6…100A 0.5…100A 0.5…63A Thermal trip Test currents: non-tripping current Inf 1.13In 1.13In 1.13In non-tripping time >1h >1h (up to 63A) > 2h (> 63A) tripping current If 1.45 In 1.45 In 1.45 In tripping time < 1h < 1h (up to 63A) < 2h (> 63A) Electro-magnetic trip Test currents: non-tripping current Im1 3In 5In 10In non-tripping time > 0.1s > 0.1s > 0.15s tripping current Im2 5In 10In 20In tripping time < 0.1s < 0.1s < 0.15s Characteristic B Characteristic C Characteristic D www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/44 Technical Details Tripping Curves Characteristics K-Z selective Tripping characteristics according to DINVDE 0660. Rated currents from 0.5 to 63A, in 16 different values. They are used to control and protect inductive circuits, power suppliers for semi-conductor electronic circuits and secondary measurement circuits, in the commercial and industrial sectors. Tripping characteristic K Z Standard IEC/EN60947 IEC/EN60947 Rated current In 0.5…63A 0.5…63A Thermal trip Test currents: non-tripping current Inf 1.05In 1.05In non-tripping time >2h >2h tripping current If 1.2In 1.2In tripping time < 2h < 2h Electro-magnetic trip non-tripping current Im1 8In 2In non-tripping time > 0.2s > 0.2s tripping current Im2 14In 3In tripping time < 0.2s < 0.2s Characteristic K Characteristic Z www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/45 D W Dimensions H Type Extra Info H W D S270 - S280 1P 85 17.5 74 2P 85 35 74 3P 85 52.5 74 4P 85 70 74 S2-H.. 85 8.75 68 S2-S - S2S/H 85 8.75 68 S2-BM 85 17.5 68 S500 1P 91 25 92 2P 91 50 92 3P 91 75 92 4P 91 100 92 S951 83 17.8 68 F360 2P 90 35 68 4P 90 70 68 DDA60 2P 94 35 68 3P 94 70 68 4P 94 70 68 DS651 - DS671 97 35 74 RD2 85 35 64.8 E240 - E270 2P 90 35 68 3P 90 52.5 68 4P 90 70 68 ESB Contactors ESB20 85 17.5 58 ESB24 85 35 58 ESB40 85 54 58 ESB63 85 54 58 E250 1P 85 17.5 58 2P 85 35 58 E220 1P 85 17.5 68 ETS 1P 85 17.5 58 3P 88.5 52.4 58 DTS 2P 85 35 58 6P 82 105 53 LE 85 35 58 TM TM10 - 12 85 35 58 TM30 - 40 85 52.5 58 TWS 82 35 60 OVR 1P 87 17.5 69 2P 87 35 69 4P 87 70 69 www.abb.com/lowvoltage email marketing.info@gb.abb.com Telephone 02476 368506 Facsimile 02476 368401 ABB LIMITED 3/46

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the S272-K32 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

BOARD FHP CONTROL 230VAC

CIRCUIT BREAKER 4AMP 1POLE

CIRCUIT BREAKER 4AMP 1POLE

CIRCUIT BREAKER 6AMP 1-POLE

product

ABB S800 I/O System for cost-effective process control, down to the last field device

product

ABB SIKAP Series Power Capacitors. Metal-enclosed type installation with or without damping reactors...