ABB RLM911
Specifications
Circuitry
Encapsulated
Form
Single pole double throw (SPDT)
Humidity
95% relative, non-condensing
Isolation Voltage
= 2500 V RMS input to output
Line Frequency
50 ... 60 Hz
Mounting
Surface mount with two #8 (M4 x 0.7) screws
Operating Temperature
-40°C ... +60°C
Phase Sequence
ABC
Rating
8 A resistive at 240 V AC; max. voltage 277 V AC
Reset
Automatic
Response Time -- Phase Reversal
=100 ms
Storage Temperature
-40°C ... +85°C
Surge
IEEE C62.41-1991 Level B
Termination
0.25 in. (6.35 mm) male quick connect terminals
Type
Electromechanical relay
Undervoltage
Trip Voltage: 88 ... 92% of adjusted line voltage
Undervoltage and Voltage Unbalance
Type: Voltage detection with delayed trip
Weight
? 8.7 oz (247 g)
Features
- Fully Adjustable or Factory Fixed
- Industrial Packaging with Encapsulated Circuitry
- LED Glows When All Conditions are Acceptable
- Line Voltages 200 ... 480 V AC, in 3 Ranges
- Protects Against: Phase Loss, Phase Reversal,
- SPDT Isolated 8 A Contacts
- Undervoltage, & Unbalance Voltages
Datasheet
Extracted Text
RLM01A01 05.31.02 Description 3 Phase Voltage Monitor The RLM Series of encapsulated three phase voltage monitors continuously measures the RLM Series voltage of each of the three phases. Its circuit Motor Protector design separately senses Phase Reversal, Undervoltage, and Voltage Unbalance including Phase Loss. Protection is assured during periods of large average voltage fluctuations, or when regenerated voltages are present. Both Delta 2 Amp and Wye systems can be monitored; no Fast Acting connection to neutral is required. Fuses Operation The output relay is energized and the LED glows when all voltages are acceptable and the phase sequence is correct. Undervoltage and voltage unbalance must be sensed for a continuous trip F = Fuses delay period before the relay and the LED are = Phase A = L1 OA de-energized. Re-energization is automatic upon ANSI Device #47/27 = Phase B = L2 OB correction of the fault condition. The output relay = Phase C = L3 OC will not energize if a fault condition is sensed as Protects Against: Phase Loss, Phase Reversal, Δ U = Unbalance Adjustment power is applied. Undervoltage, & Unbalance Voltages Δ V = Line Voltage Adjustment Industrial Packaging with Encapsulated Circuitry ΔT = Trip Delay Adjustment ASME A17.1 rule 210.6, NEMA MG1 14:30, 14:35, Fully Adjustable or Factory Fixed IEEE C62.41-1991 Level B SPDT Isolated 8 A Contacts CAUTION: 2 amp max. fast acting fuse must LED Glows When All Conditions are Acceptable Approvals: be installed externally in series with each input. Line Voltages 200 ... 480 V AC, in 3 Ranges (3) (Bussman KTK-2 or equivalent) Ordering Table X X X RLM Series Line Voltage Voltage Unbalance Trip Delay –6 - 240 V AC –1 - Adjustable: 2 ... 6 % –1 - Adjustable: 2 ... 20 s –9 - 480 V AC –Fixed: Specify: 4, 5, 6, 7, or 8 % –Fixed: Field Adjustment: Set voltage, delay period, Specify delay in s, and voltage unbalance percentage (consult –8 - 380 V AC –1 - Adjustable: 2 ... 8 % (380 V AC only) 2 ... 20 s in 1 s increments equipment manufacturer's specifications). Make –Fixed: Specify: 4, 5, 6, 7, or 8 % (insert 0 before 2 ... 9) connection to all three line phases as shown in the connection diagram. Apply power. If the Example P/N: RLM611 Fixed - RLM9405 relay fails to energize, check the wiring of all 3 Technical Data phases, voltage, and phase sequence. If phase sequence is incorrect, swap any two wires. No Line Voltage further adjustment should be required to achieve Type 3 phase Delta or Wye with no connection to neutral maximum equipment protection. Operating Voltage: UL CSA Model Adj. Line Voltage Range Line Voltage Max. Calibration Frequency • • 240 200 ... 240 V AC 270 V AC 60 Hz • 380 360 ... 430 V AC 480 V AC 50 Hz • • 480 400 ... 480 V AC 530 V AC 60 Hz Line Frequency 50 ... 60 Hz Phase Sequence ABC Undervoltage and Voltage Unbalance Type Voltage detection with delayed trip & automatic reset Undervoltage: Trip Voltage 88 ... 92% of adjusted line voltage Inches(Millimeters) Reset Voltage +3% of trip voltage Voltage Unbalance: Trip Unbalance 240 & 480 V AC Adj. 2 ... 6%; 380 V AC Adj. 2 ... 8%; or fixed at 4, 5, 6, 7, or 8% Reset on Balance (%): Selected Unbalance 2 3 4 5 6 7 8 Reset 1.8 2.7 3.6 4.5 5.4 6.3 7.2 Note: A 60 Hz unit used on 50 Hz will shift by -1. A 50 Hz unit used on 60 Hz will shift by +1. (Ex: 4% unbalance on 60 Hz would be 3% unbalance on 50 Hz. Trip Delay: Range Adjustable or Factory fixed from 2 ... 20 s Tolerance Adjustable: Guaranteed range; Factory fixed: +/-15% Phase Reversal Response Time -- Phase Reversal ≤100 ms Reset Automatic Output Type Electromechanical relay Form Single pole double throw (SPDT) Rating 8 A resistive at 240 V AC; max. voltage 277 V AC Protection Surge IEEE C62.41-1991 Level B Isolation Voltage ≥ 2500 V RMS input to output Circuitry Encapsulated Accessories Mechanical Mounting Surface mount with two #8 (M4 x 0.7) screws Termination 0.25 in. (6.35 mm) male quick connect terminals L Environmental W Operating Temperature -40°C ... +60°C Storage Temperature -40°C ... +85°C Female quick connect Fuse 2A fast acting P/Ns: Humidity 95% relative, non-condensing 1.5“ x 13/32“ 3-phase fuse P1015-13 (AWG 10/12) Weight ≅ 8.7 oz (247 g) (38.1 mm x 10.3 mm) block/disconnect P1015-64 (AWG 14/16) P/N: P0600-11 P/N: P0700-241 P1015-14 (AWG 18/22) See accessory page at the end of this section. 260
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the RLM911 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods