ABB RLM611
Datasheet
Extracted Text
3 Phase V 3 Phase V 3 Phase V 3 Phase V 3 Phase Voltage Monitor oltage Monitor oltage Monitor oltage Monitor oltage Monitor RLM Series Motor Protector Description Description Description Description Description The RLM Series of encapsulated three phase voltage monitors continuously measures the voltage of each of the three phases. Its circuit design separately senses Phase Reversal, Undervoltage, and Voltage Unbalance including Phase Loss. Protection is assured during periods of large average voltage fluctuations, or when regenerated voltages are present. Both Delta and Wye systems can be monitored; no connection to neutral is required. Operation Operation Field Adjustment: Field Adjustment: Operation Operation Operation Field Adjustment: Field Adjustment: Field Adjustment: ANSI Device #47/27 The output relay is energized and the LED glows when Set voltage, trip delay, and voltage unbalance all voltages are acceptable and the phase sequence percentage (consult equipment manufacturer's is correct. Undervoltage and voltage unbalance must specifications). Make connection to all three line be sensed for a continuous trip delay period before phases as shown in the connection diagram. Protects Against: Phase the relay and the LED are de-energized. Re- Apply power. If the relay fails to energize, check Loss, Phase Reversal, energization is automatic upon correction of the fault the wiring of all 3 phases, voltage, and phase Undervoltage & condition. The output relay will not energize if a fault sequence. If phase sequence is incorrect, swap Unbalance Voltages condition is sensed as power is applied. any two wires. No further adjustment should be Industrial Packaging with required to achieve maximum equipment Encapsulated Circuitry protection. Fully Adjustable or Factory Fixed SPDT Isolated 8 A Contacts LED Glows When All Conditions are Acceptable Line Voltages 200 ... 480 V AC in 3 Ranges ASME A17.1 rule 210.6 NEMA MG1 14:30, 14:35 IEEE C62.41-1991 Level B Approvals: Connection Connection Connection Connection Connection F = Fuses = Phase A = L1 OA = Phase B = L2 OB 2 Amp = Phase C = L3 OC Fast Acting ∆ U = Unbalance Adjustment Fuses ∆ V = Line Voltage Adjustment ∆T = Trip Delay Adjustment Dashed lines are internal connections. Accessories Accessories Accessories Accessories Accessories CAUTION: CAUTION: CAUTION: CAUTION: CAUTION: 2 amp max. fast acting fuse must Female quick connect be installed externally in series with each input. P/Ns: P1015-13 P1015-13 P1015-13 P1015-13 P1015-13 (AWG 10/12) P1015-64 P1015-64 P1015-64 P1015-64 P1015-64 (AWG 14/16) P1015-14 P1015-14 P1015-14 P1015-14 P1015-14 (AWG 18/22) Or Or Or Or Ordering T dering T dering T dering T dering Table able able able able X X X X X X RLM RLM RLM RLM RLM X X X X X X X X X 3-phase fuse Series Series Series Series Series Line V Line V Line V Line V Line Voltage oltage oltage oltage oltage V V V V Voltage Unbalance oltage Unbalance oltage Unbalance oltage Unbalance oltage Unbalance T T T T Trip Delay rip Delay rip Delay rip Delay rip Delay block/disconnect 6 6 1 1 2 2 6 6 1 1 2 2 20 20 –6 6 6 - 240 V AC –1 1 1 - Adjustable: 2 2 2 ... 6 6 6 % –1 1 1 - Adjustable: 2 2 2 ... 20 20 20 s P/N: P0700-241 P0700-241 P0700-241 P0700-241 P0700-241 9 9 4 4 5 5 6 6 7 7 8 8 –9 9 9 - 480 V AC –Fixed: Specify: 4 4 4, 5 5 5, 6 6 6, 7 7 7, or 8 8 8 % –Fixed: Specify delay in s, 2 Amp Fuse 2 2 20 20 2 2 2 ... 20 20 20 s in 1 s increments P/N: P0600-11 P0600-11 P0600-11 P0600-11 P0600-11 8 8 1 1 2 2 8 8 0 0 2 2 9 9 –8 8 8 - 380 V AC –1 1 1 - Adjustable: 2 2 2 ... 8 8 8 % (380 V AC only) (insert 0 0 0 before 2 2 2 ... 9 9 9) 4 4 5 5 6 6 7 7 8 8 –Fixed: Specify: 4 4 4, 5 5 5, 6 6 6, 7 7 7, or 8 8 8 % RLM611 RLM611 RLM9405 RLM9405 See accessory pages for Example P/N: Example P/N: Example P/N: Example P/N: Example P/N: RLM611 RLM611 RLM611 Fixed - RLM9405 RLM9405 RLM9405 specifications. RLM9405 is a 480 V AC 60 Hz unit, unbalance fixed at 4%, trip delay fixed at 5 seconds. 7.12 Low Voltage Products & Systems RLM02B01 10.06.04 RLM02B01 10.06.04 3 Phase V 3 Phase V 3 Phase V 3 Phase V 3 Phase Voltage Monitor oltage Monitor oltage Monitor oltage Monitor oltage Monitor RLM Series Motor Protector Technical Data Technical Data Technical Data Technical Data Technical Data Line V Line V Line V Line V Line Voltage oltage oltage oltage oltage Type 3 phase Delta or Wye with no connection to neutral Operating Voltage UL CSA Model Line V UL CSA Model Line V UL CSA Model Line V UL CSA Model Line V UL CSA Model Line Voltage Range Line V oltage Range Line V oltage Range Line V oltage Range Line V oltage Range Line Voltage Max. Calibration Fr oltage Max. Calibration Fr oltage Max. Calibration Fr oltage Max. Calibration Fr oltage Max. Calibration Frequency equency equency equency equency • • 240 200 ... 240 V AC 270 V AC 60 Hz • 380 360 ... 430 V AC 480 V AC 50 Hz • • 480 400 ... 480 V AC 530 V AC 60 Hz Line Frequency 50 ... 60 Hz Phase Sequence ABC Undervoltage and V Undervoltage and V Undervoltage and V Undervoltage and V Undervoltage and Voltage Unbalance oltage Unbalance oltage Unbalance oltage Unbalance oltage Unbalance V V V V Voltage Unbalance oltage Unbalance oltage Unbalance oltage Unbalance oltage Unbalance Type Voltage detection with delayed trip & automatic reset Selected Unbalance % Reset % Undervoltage: Trip Voltage 88 ... 92% of adjusted line voltage Reset Voltage +3% of trip voltage 21.8 Voltage Unbalance: 32.7 Trip Unbalance 240 & 480 V AC Adj. 2 ... 6% 43.6 380 V AC Adj. 2 ... 8%; or fixed at 4, 5, 6, 7, or 8% 54.5 Trip Delay: Range Adjustable or Factory fixed from 2 ... 20 s 65.4 76.3 Tolerance Adjustable: Guaranteed range; Factory fixed: +/-15% 87.2 Phase Reversal Phase Reversal Phase Reversal Phase Reversal Phase Reversal Response Time -- Phase Reversal ≤100 ms Note: Note: N Note: Note: ote: A 60 Hz unit used on 50 Hz will Reset Automatic shift by -1. A 50 Hz unit used on 60 Hz Output Output Output Output Output will shift by +1. (Ex. 4% unbalance on 60 Type Electromechanical relay Hz, would be 3% unbalance on 50 Hz.) Form Single pole double throw (SPDT) Rating 8 A resistive at 240 V AC; 1/4 hp at 125 V AC; 1/3 hp at 250 V AC; max. voltage 277 V AC 6 Life Mechanical -- 1 x 10 5 Electrical -- 1 x 10 Protection Protection Protection Protection Protection Surge IEEE C62.41-1991 Level B Isolation Voltage ≥ 2500 V RMS input to output Circuitry Encapsulated Mechanical Mechanical Mechanical Mechanical Mechanical Mounting Surface mount with two #8 (M4 x 0.7) screws Package 4.5 x 3.12 x 1.35 in (114.3 x 79.3 x 34.3 mm) Termination 0.25 in. (6.35 mm) male quick connect terminals Environmental Environmental Environmental Environmental Environmental Operating Temperature -40°C ... +60°C Storage Temperature -40°C ... +85°C Humidity 95% relative, non-condensing Weight ≅ 8.7 oz (247 g) Mechanical View Mechanical View Mechanical View Mechanical View Mechanical View Inches (Millimeters) Low Voltage Products & Systems 7.13
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the RLM611 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods