XP POWER JPS250PQ46
Specifications
Cooling
250 W with 18 CFM airflow
Current Share
Single wire current sharing on single output models & V1 & V2 of multi-output models (4 supplies can be paralleled)
Earth Leakage Current
2.0 mA max 264 VAC/60 Hz
Efficiency
Up to 88%
Fan Output
5 V model: 5 V at 390 mA,
Hold Up Time
20 ms min at low line & rated load
Initial Set Accuracy
At 60% rated load ±1% on V1 & V2, ±5% on V3 & V4
Input Current
2.75 A/1.40 A max at 115 VAC/230 VAC
Input Frequency
47-63 Hz
Input Protection
Internal 5 A, 250 V fuse
Input Voltage
90-264 VAC (170-370 VDC)
Inrush Current
30 A at 115 VAC, 60 A at 230 VAC
Isolation
3000 VAC Input to Output
Line Regulation
±0.5% at rated load across input voltage range
Load Regulation
±1% for single output models & V1 & V2 of multi-output models, ±5% for V3 & V4
Minimum Load
Single output models: No minimum load required. Multi-output models, see note 4
MTBF
255 kHrs per MIL-HDBK-217F at +25 °C
Operating Altitude
3000 m
Operating Humidity
5-95% RH, non-condensing
Operating Temperature
0 °C to +70 °C, (see derating curve) Full power to +50 °C
Output Voltage Trim
±10% on output 1 only
Overload Protection
110-130% of max rated load on all O/Ps, trip & restart (Hiccup mode), auto recovery
Overtemperature
Shuts down at +110 °C, auto recovery Protection measured internally
Overvoltage Protection
115-140% on single outputs & V1 of quad output models, recycle input to reset
Power Density
4.96 W/In3
Power Factor
0.99 typical
Remote On/Off
On - Logic Low or Open, Off - Logic High
Remote Sense
Compensates for up to 0.5 V drop
Ripple & Noise
±1% max pk-pk, 20 MHz BW
Short Circuit Protection
Trip and restart (Hiccup mode)
Signals
AC OK, DC OK, Remote On/Off (see control and supervisory signals)
Start Up Delay
2 s typical
Start Up Rise Time
80 ms typical
Storage Temperature
-20 °C to +85 °C
Switching Frequency
120 kHz typical for PFC and PWM
Temperature Coefficient
±0.05%/°C
Transient Response
4% max deviation, recovery to within 1% in 500 µs for a 25% load change
Vibration
2 g, 10 Hz to 55 Hz, 3 mins/cycle for 30 mins each axis
Features
- 200 W with Convection Cooling
- AC OK & DC OK Signals
- Current Share
- High Efficiency - up to 88%
- Meets 1U, Low Profile Requirements
- Remote On/Off & Remote Sense
- Zero Voltage Switching Technology
Datasheet
Extracted Text
250 Watts xppower.com JPS250 Series • 200 W with Convection Cooling • High Efficiency - up to 88% • Meets 1U, Low Profile Requirements • AC OK & DC OK Signals • Zero Voltage Switching Technology • Remote On/Off & Remote Sense • Current Share Specification Input General Input Voltage • 90-264 VAC (170-370 VDC) Efficiency • Up to 88% Input Frequency • 47-63 Hz Isolation • 3000 VAC Input to Output 1500 VAC Input to Ground Input Current • 2.75 A/1.40 A max at 115 VAC/230 VAC 500 VAC Output to Ground Inrush Current • 30 A at 115 VAC, 60 A at 230 VAC Switching Frequency • 120 kHz typical for PFC and PWM Power Factor • 0.99 typical 3 Power Density • 4.96 W/In Earth Leakage Current • 2.0 mA max 264 VAC/60 Hz Signals • AC OK, DC OK, Remote On/Off Input Protection • Internal 5 A, 250 V fuse (see control and supervisory signals) MTBF • 255 kHrs per MIL-HDBK-217F at +25 °C Output Output Voltage • See tables Environmental Output Voltage Trim • ±10% on output 1 only Operating Temperature • 0 °C to +70 °C, (see derating curve) Initial Set Accuracy • At 60% rated load ±1% on V1 & V2, Full power to +50 °C ±5% on V3 & V4 Cooling • 250 W with 18 CFM airflow Minimum Load • Single output models: No minimum load 200 W convection cooling required. Multi-output models, see note 4 Operating Humidity • 5-95% RH, non-condensing Start Up Delay • 2 s typical Storage Temperature • -20 °C to +85 °C Start Up Rise Time • 80 ms typical Operating Altitude • 3000 m Hold Up Time • 20 ms min at low line & rated load Vibration • 2 g, 10 Hz to 55 Hz, Line Regulation • ±0.5% at rated load across input 3 mins/cycle for 30 mins each axis voltage range Load Regulation • ±1% for single output models & V1 & V2 EMC & Safety of multi-output models, ±5% for V3 & V4 Emissions • EN55022, level B conducted Transient Response • 4% max deviation, recovery to within FCC 20780, level B conducted 1% in 500 µs for a 25% load change Harmonic Currents • EN61000-3-2 Ripple & Noise • ±1% max pk-pk, 20 MHz BW Voltage Flicker • EN61000-3-3 Overvoltage Protection • 115-140% on single outputs & V1 of quad ESD Immunity • EN61000-4-2, level 3 Perf Criteria A output models, recycle input to reset Radiated Immunity • EN61000-4-3, 10 V/m Perf Criteria A Overtemperature • Shuts down at +110 °C, auto recovery EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Protection measured internally Overload Protection • 110-130% of max rated load on all O/Ps, Surge • EN61000-4-5, level 3 Perf Criteria A trip & restart (Hiccup mode), auto recovery Safety Approvals • EN60950-1:2001, UL60950-1, CSA C22.2 No. 60950-1-03, Short Circuit Protection • Trip and restart (Hiccup mode) CE Mark LVD Temperature • ±0.05%/°C Coefficient Remote Sense • Compensates for up to 0.5 V drop Remote On/Off • On = Logic Low or Open, Off = Logic High Current Share • Single wire current sharing on single output models & V1 & V2 of multi-output models (4 supplies can be paralleled) Fan Output • 5 V model: 5 V at 390 mA, 24 V model: 24 V at 80 mA, all other models: 12 V at 112 mA AC-DC AC-DC JPS250 - Single Output Models and Ratings Output Output Output Current Ripple & Noise Model Efficiency (1) (2) Power Voltage Convection-cooled 18 CFM Pk-Pk Number 225 W 5 V 36.0 A 45.0 A 50 mV 83% JPS250PS05C†^ 12 V 17.0 A 21.0 A 120 mV 86% JPS250PS12C†^ 15 V 13.5 A 17.0 A 120 mV 87% JPS250PS15C†^ 250 W 24 V 8.5 A 10.4 A 200 mV 88% JPS250PS24C†^ 48 V 4.3 A 5.2 A 200 mV 88% JPS250PS48C†^ Notes 1. Maximum power with 18 CFM forced air is 250 W, or 200 W with convection cooling. 2. For non-current share version delete suffix ‘C’ from model number. † Available from Farnell. See pages 204-206. ^ Available from Newark. See pages 207-208. Mechanical Details All dimensions are in inches (mm) Tolerance: ± 0.03 (0.8) max Weight: 1.65 lbs (750 g) approx. All models (except JPS250PS05) 8.00 (203.2) PIN CONNECTIONS A B B A 10 L TB2 TB4 TB4 Pin N 2 1 JPS250PS05 All other models All models + E TB3 - 1 +5 V +V Signal 0 V TB1 1 3.75 4.20 2 +5 V +V DC OK (95.3) (106.7) 3 0 V +V AC OK TB2 TRANSFORMER 4 0 V 0 V Remote On/Off 6 5 0 V 0 V +Sense A A B B 6 0 V 0 V -Sense (6) 5.50 (139.0) 7 +5 V Current Share 6.50 (165.1) 8 +5 V N/C 9 N/C 0.30 7.40 (188.0) (7.6) 10 N/C A A 1.51 Notes: B B (38.3) 0.75 1. TB3 is for fan, with Molex 5045-02A or equivalent. (19.1) 2. TB1 (AC input) and TB2 (DC output) are terminal blocks. 0.36 3. TB4 signal connector is Molex 70246-10 or equivalent. (9.1) 4. Maximum mounting screw penetration is 0.16 (4.0) from chassis outer surface. JPS250PS05 5. Fan/Cover option available, order part number: 8.00 (203.2) † 5 V models: JPS250 F/CVR 5 ^ † 12, 15 & 48 V models: JPS250 F/CVR ^ 2 10 A B † 24 V models: JPS250 F/CVR 24 ^ TB4 L 1 Or add suffix ‘-E’ to model number to receive unit with cover fitted. N 1 6. For current share operation connect signal 0 V (pin 1) between E units and current share (pin 7) between units. For non ‘C’ models TB1 3.75 4.20 pin 7 (single wire parallel) is not used. (95.3) (106.7) TB2 Fixing Holes: TRANSFORMER A = #6-32 screw mounting holes + TB3 - 8 B = M3 x 0.5 screw mounting holes A B B A 1.30 (32.1) 5.50 (139.0) 0.70 (19.1) 6.50 (165.1) Application Notes Derating Curve Signals 100 1. To turn off the output, apply 5 V to the remote On/Off. 90 JPS250PS with 18 CFM Fan 2. AC OK is a TTL signal which goes LOW when input falls below 80 L 60 VAC at rated load. JPS250PS Convection-cooled 70 O 3. DC OK is a TTL signal which goes LOW when PSU is in an 60 A D 50 overcurrent condition, overvoltage condition, disabled or when 40 output falls out of regulation. %) 30 4. For AC OK and DC OK signals, source current is 1 mA, sink 20 current is 6 mA. 10 0 0 10 20 30 40 80 50 60 70 Ambient Temperature (˚C) JPS250 - Multi Output Models and Ratings Output 1 Output 2 Output 3 Output 4 Model Output Conv. Max Output Conv. Max Output Conv. Max Output Conv. Max (2,3) Number V1 Cooled 18 CFM V2 Cooled 18 CFM V3 Cooled 18 CFM V4 Cooled 18 CFM † 3.3 V 16.0 A 20 A 5 V 12 A 20 A 12 V 5 A 6 A -12 V 1 A 2 A JPS250PQ46 ^ † 5.0 V 17.5 A 30 A 12 V 7 A 8 A -12 V 2 A 3 A -5 V 1 A 2 A JPS250PQ41 ^ † 5.0 V 20.0 A 25 A 12 V 4 A 6 A 24 V 2 A 3 A -12 V 1 A 2 A JPS250PQ47 ^ † 5.0 V 20.0 A 25 A 15 V 3 A 5 A 24 V 2 A 3 A -15 V 1 A 2 A JPS250PQ48 ^ Notes 1. Maximum power with 18 CFM forced air is 250 W, or 200 W with convection cooling. 2. For current share option add suffix ‘C’ to model number. 3. Current share models are built to order. 4. All models require 2 A minimum load on V1. On V2, JPS250PQ46 requires 1 A and JPS250PQ41 requires 0.5 A. † Available from Farnell. See pages 204-206. ^ Available from Newark. See pages 207-208. Mechanical Details All dimensions are in inches (mm). Tolerance: ± 0.03 (0.8) max. Weight: 1.65 lbs (750 g) approx. PIN CONNECTIONS - TB2 8.00 (203.2) Pin PQ41 PQ46 PQ47 PQ48 1 +5 V +S +3.3 V +S +5 V +S +5 V +S 1 L (6) (6) (6) 2 +5 V PS +5 V -S +5 V PS +5 V PS N (6) 3 +12 V +S +3.3 V PS +12 V +S +15 V +S E TB3 TRANSFORMER 4 DC OK DC OK DC OK DC OK TB1 2 10 4.20 TB2 5 +12 V -S +5 V +S +12 V -S +15 V -S (106.7) 1 8 6 +5 V -S +3.3 V -S +5 V -S +5 V -S (6) (6) (6) (6) 7 +12 V PS +5 V PS +12 V PS +15 V PS TB5 8 Remote On/Off Remote On/Off Remote On/Off Remote On/Off + - 9 AC OK AC OK AC OK AC OK 10 0 V 0 V 0 V 0 V 0.30 7.40 (187.9) 0.16 (4.0) (7.6) PIN CONNECTIONS - TB3 A A 1.30 1.50 Pin PQ41 PQ46 PQ47 PQ48 (33.1) (38.1) B B 0.75 1 +5 V +12 V +5 V +5 V (19.1) 2 +5 V -12 V +5 V +5 V 0.36 (9.1) 3 0 V +5 V 0 V 0 V 4 0 V +5 V 0 V 0 V 8.00 (203.2) 5 0 V 0 V 0 V 0 V A B BA 6 -5 V 0 V -12 V -15 V 7 -12 V 0 V +24 V +24 V 8 +12 V 0 V +12 V +15 V 9 +3.3 V 3.75 (95.3) 10 +3.3 V 1.30 (32.1) Notes: 0.70 1. TB5 is for fan with Molex 5045-02A or equivalent. (19.1) A B BA 2. TB1 (AC input) and TB3 (DC output) are terminal blocks. 3. TB2 signal connector is Molex 70246-10 or equivalent. 5.50 (139.0) 0.22 (5.7) 4. Maximum mounting screw penetration is 0.16 (4.0) from chassis 6.50 (165.1) outer surface. 5. Fan/Cover option available, order part number: Fixing Holes: † † PQ41, PQ46 & PQ47: JPS250 F/CVR PQ48: JPS250 F/CVR 24 A = #6-32 screw mounting holes or add suffix ‘-E’ to model number to receive unit with cover fitted. B = M3 x 0.5 screw mounting holes 6. PS - Single wire parallel on ‘C’ models only. No connection on standard models. Application Notes Derating Curve Signals 100 1. To turn off the output, apply 5 V to the remote On/Off. 90 JPS250PQ with 18 CFM Fan 2. AC OK is a TTL signal which goes LOW when input falls below 80 L 60 VAC at rated load. 70 JPS250PQ Convection-cooled O 60 3. DC OK is a TTL signal which goes LOW when PSU is in an A 50 D overcurrent condition, overvoltage condition, disabled or when 40 output falls out of regulation. (%) 30 4. For AC OK and DC OK signals, source current is 1 mA, sink 20 current is 6 mA. 10 0 0 10 20 30 40 50 60 70 80 Ambient Temperature (˚C) AC-DC AC-DC 1.70 (43.2) JPS250 Control & Supervisory Signals AC OK Signal DC OK Signal +5 V +5 V 330 R 330 R AC OK (HIGH) DC OK (HIGH) AC OK DC OK GND GND AC NOT OK (LOW) DC NOT OK (LOW) Remote On/Off Control (Inhibit) Parallel Connection Utilizing Optional Current Share Output Supply 1 Return OUTPUTS OFF (5V) Remote On/Off V1 Single Wire Parallel LOAD Comm Ground Output Supply 2 OUTPUTS ON (0 V or open circuit) Return Single Wire Parallel Remote Sense Connection Output + CD + Sense + Notes: Twisted Pair LOAD CL 1. CD is 0.1 µF ceramic capacitor. Supply - 2. CL i s 47 µF electrolytic capacitor. Sense - CD Output - JPS250 Fan/Cover Option See mechanical details notes for information on how to order. Typical internal clearance 0.15 (3.8) 4 x M3 x 6 C/S head fixing screws in existing countersunk holes 04-June-07 2.48 (62.9)
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the JPS250PQ46 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods