Elite.Parts Manufacturers W WESTELL DTWA-528-0212
About product Datasheet FAQ

WESTELL DTWA-528-0212

Description

HYPER_CHAS_2PO

Part Number

DTWA-528-0212

Price

Request Quote

Manufacturer

WESTELL

Lead Time

Request Quote

Category

PRODUCTS - D

Datasheet

pdf file

dtwa528-02i2.pdf

719 KiB

Extracted Text

SectionDTW-A52-802-202 R EquipmentIssue2 030-101584Rev.A,March2006 DTWA528-02I2Series2-SlotUniversalDataMounting CONTENTS PAGE# 1. GENERAL ................................... 1 2. OPTIONS&FEATURES ....................... 2 3. INSTALLATION .............................. 3 4. TROUBLESHOOTING ........................ 6 5. CUSTOMER&TECHNICALSERVICES ........ 6 6. WARRANTY&REPAIRS ...................... 6 7. SPECIFICATIONS ............................ 6 1. GENERAL 1.1 DocumentPurpose Figure1. IsometricViewofDTWA528-02I2 This document describes the Westell DTWA528-02I2 2-Slot Universal,DataMountingAssemblySeries.Atypicalmounting 528-02I2alsomaybesetonadesk,shelf,ortabletopforhorizon- isshowninFigure1. tal mounting. The 528-02I2 can also be installed in a 19-inch or 23-inch equipment rack by specifying the mounting bracket kit, ModelMBA1923-2. -NOTE - Hereafter, theDTWA528-02Issue2seriesmaybereferredtoas the“528-02I2”or“assembly.” 1.5 ProductFeatures Featuresofthe528-02I2areasfollows: 1.2 DocumentStatus S Small footprint Whenever this practice is updated, the reason will be stated in thisparagraph. S Acceptseitherone400-typemoduleorupto two200-type modules for use in Hi-Cap/T1/Digital/Analog applications 1.3 ProductPurposeandApplication S Network connections made to screw terminal blocks or The528-02I2isauniversal,datawall-mountassemblywhichhas wirewrap pins, depending on list option ordered twoslotsorcircuitstoterminateeitherone400-mechanics-type S Customer connections to screw terminal blocks (or module or two 200 MECHANICSr-type modules (high-densi- ty). The assembly accepts modules designed for the purposes wirewrap pins) or to two RJ48C/S jacks listedbelow(alsoseeFigure2for typicalapplications). S Power/ground connections made to screw terminal block S Network Interface Units (NIUs) in 1.544 Mb/s Hi-Cap S 2 switches enable user to switch between RJ48C or RJ48S digital (T1) and High-bit-rate Digital Subscriber Line jack applications (HDSL) applications S Optional powersupplyprovided whentheList6 Optionis S DSTs in Analog Data Service applications selected. S DDIs in Digital Data Service applications S Tinted,see-through,frontwindowallowsvisualmonitoring of plug-inmodule’sstatusLEDspluseasymoduleaccess S Any combination of the above applications S Built-inswing-out bracket allows(lockable, List 4 Option) AllNetworkInterface(Telco)connectionsaremadeatscrewter- cover to swing-out to provide easy access to all internal minal blocks (or wirewrap pin headers for the List 9 Option). components and doubles as a 2-slot module housing Customer Interface (Cl) connections are made through either RJ48C/Smodularjacksoratscrewterminalblocks(orwirewrap S In closed position, assembly allows convenient rear access pinheadersfortheList9Option).Alockingmetalliccoverpro- to customer RJ48C/S jacks while protecting the Telco and tectstheCustomerandTelcoconnectionswhentheList4Option customer terminal block connections isselected. S Compact,versatile,wall-mountableortabletop-mountable 1.4 ProductMounting metallic case The528-02I2istypicallywall-mountedatthecustomerpremises S Wiring diagram provided on the inside cover on the network side of the point of demarcation. Holes for mountingscrewsareprovidedinthebottomoftheassembly.The S Chassis ground lug ECopyright2006Westell,Inc. Allrightsreserved. 200MECHANICSrisaregisteredtrademark ofWestell,Inc.,andCLEIisatrademarkofTelcordiaTechnologies. Page1 of 6 SectionDTW-A52-802-202 030-101584Rev.A R CentralOffice 528-02I2 Cross Connect Telco#1 CPE#1 RJ48C NIU IOR CPE Test #1 TB1 TB2/J1 ILR ILR Equipment Figure2a. 528-02I2ConfiguredasaSingleNIUMounting,UsingaStandard400-or200-MECHANICSNIU 528-02I2 CentralOffice Telco#2 RJ48C CPE#2 HTU-C HTU-R CPE Cross TB3 TB4/J2 Connect Telco#1 RJ48C CPE#1 HTU-C HTU-R CPE Test TB1 TB2/J1 Equipment Figure2b. 528-02I2ConfiguredasaDualMounting,UsingtwoHDSL200-MECHANICSUnits CentralOffice 528-02I2 Cross Connect Telco#1 CPE#1 RJ48S DST ISQ CPE TB1 #1 TB2/J1 Test Equipment Figure2c. 528-02I2ConfiguredasaSingleDSTorDDIMounting,UsingaStandard400-or200-MECHANICSDSTorDDIModules CPE=Cust.PremisesEquipment ISQ=Intelligent ETO ILR=Intelligent LineRepeater IOR=Intelligent OfficeRepeater NIU=NetworkInterfaceUnit Figure2. 528-02I2Applications configurationtobeused,eitherRJ48CorRJ48S.Table3listsCI S Cable ties (provided) connections. S NEBS Level 3 certified S UL 60950 listed by an NRTL S1/S2Position ApplicationType S Certified to CAN/CSA-C22.2 No. 60950 RJ48C T1, Hi-Cap, NIU, HDSL RJ48S AnalogDataServices,DSTModule,Digital DataService,DDIModule,IDSL(ISDNDSL) 2. OPTIONS&FEATURES Table1. S1/S2PositionsforTypicalApplications/Modules The 528-02I2 contains various features, switches, and terminal blocks,asshowninFigure3andFigure4anddescribedbelow, tooptiontheunitforproperoperation. 2.3 S1andS2SlideSwitches -List9WIREWRAPPINNOTE - The528-02I2containstwoslideswitches,S1andS2, toprovision The528-02I2,List6provideswirewrappinconnectorsinsidetheunitfor the J1 and J2 customer RJ48 jacks for use in an RJ48C or an NetworkandCustomerconnections,insteadofscrewterminals.Substi- RJ48S configuration. If the customer application requires tutetheterm“wirewrappinheader”for“screwterminalblock”whenref- RJ48Cjacks,setS1andS2totheRJ48Cposition.Ifthecustomer erencingthe528-02I2,List9. application requires RJ48S jacks, set S1 and S2 to the RJ48S position.Ifa400-typemodule(twicethewidthof200-typemod- 2.1 TB1andTB3-Telco/NetworkConnections ules)isusedintheassembly,itisinsertedintothetopslot(when intheclosedposition)andinterfaceswithJ1andS1. TB1andTB3are4-positionscrewterminalblocksforterminat- ingtheTelco/Networkconnections.ThefourpositionsareT,R, T1andR1,asshowninTable2.TB1isusedtointerfacewithcir- 2.4 TB5-PowerandGroundConnections cuit/module#1andTB3isusedtointerfacewithcircuit/module #2.Ifa400-typemodule(twicethewidthof200-typemodules) TB5 is a 4-position screw terminal block for power and ground isused,itisinsertedintoslot/circuit#1(topslotwhenassembly connections to the assembly. The four positions are +PWR, isintheclosedposition)andinterfaceswithTB1. FRAMEGND,CIRCUITGNDand-PWR,aslistedinTable4. The +PWR position is used to connect the positive terminal fromtheModelWPS4802(115VACto48VDC),orequivalent 2.2 TB2andTB4,orJ1andJ2RJ48C/SJacks- powersupply.FRAMEGNDisavailableasanoptiontoconnect CustomerPremisesEquipmentConnections toEarthgroundasstatedinParagraph2.5.CIRCUITGNDmust Customer Premises Equipment (CPE) connections to the as- beconnectedtoanearthgroundregardlessofthepowersource. semblycanbemadetothe4-positionscrewterminalblocksTB2 Useaninsulatedwireof24AWGorgreater(seeFigure7).The andTB4ortojacksJ1andJ2(eitherRJ48CorRJ48S-typemod- -PWRpositionisusedtoconnectthenegativeterminalfromthe ular jacks). Setting Switches S1 and S2 selects the correct WPS4802(orequivalent48voltpowersupply). 2 CKT1 CKT2 030-101584Rev.A R SectionDTW-A52-802-202 Wall-Mount Keyhole (Total of 4) RJ48C/S Switch Ckt 1 NetworkSide TerminalBlock* Power/Ground TerminalBlock Shorting Bar/ Ground Jumper RJ48C/S Switch Ckt 2 CustomerSide TerminalBlock* * List 9 contains wirewrap pin headers instead of screw terminals. Figure3. TopViewof528-02I2Interior(CoverOpenforVisualClarity),TypicalWall-MountedPosition 2.5 FrameGroundConnections Wiring Label The metal housing can be connected to earth ground by using Card Guides oneofthemethodsbelow.Onsomeunits,thisoptionalstrapis ForModules providedinthepartsbag,andontheDTMA528-02L4itis facto- ryinstalled. S Exterior Frame Ground Lug on Rear of Assembly (PreferredMethod).Aframegroundlug,labeledFRAME 256-pinCard Edge Connectors GND, is provided on the rear of the metal housing. This Ribbon Cable lug should be used to connect the metal housing to earth ground. S Interior TB5 Frame Ground Screw Terminal (Inside Assembly).Aframegroundscrewterminal, labeledTB5, RJ48S located inside the assembly can be used as an optional method for earth grounding the metal housing (Figure 3 Hinged Cover, RJ48C Opens For and Figure 8) when local power is supplied. Access S1, RJ48C/S Network To Wiring Switch, CKT1 TerminalBlock* S Optional Interior TB5 Removable Ground Strap. The 528-02I2 features a factory-assembled, pre-installed, J2, Customer groundstrapforapplicationsrequiringframegroundtobe RJ Jack, connectedtocircuit ground.Thestrapisconnectedacross Rear- Accessible TB5’s FRAME GND and CIRCUIT GND terminals. On some units, this optional strap is provided, but not RJ48S factory-installed. See-through Module RJ48C Window Customer S2, JR48C/S 3. INSTALLATION Power/Ground TerminalBlock* Switch, CKT2 TerminalStrip * The List 9 Option contains wire-wrap pins in place of screw terminals. Theassemblyshouldbeinstalledbyauthorized,trainedperson- nelonly.InaccordancewithUL60950,thisassemblyissuitable formountingonconcreteorothernoncombustiblesurfacesonly Figure4. 528-02I2Interior,CoverOpen,TypicalTable- andisforuseinrestrictedaccesslocationsonly.Installationcon- topMountPosition sists of inspecting the assembly for damage, selecting the mountingsiteorlocation,gatheringallnecessarytoolsandhard- ware, mounting the assembly, making all grounding and power connections, performing the installer connections for network 3 SectionDTW-A52-802-202 030-101584Rev.A R Lock S Drillanddrillbits(todrillholesformountingscrews/bolts) Ground Lug S Mounting hardware (four screws or bolts) 3.3 MountingtheAssemblytoaWall R 1. Loosen the top-cover screw or, if key lockable, insert the key androtatethekeylocktounlockthecover. 2. Using the mounting screw keyholes in the assembly’s base plateasatemplate,carefullylifttheassemblytothedesired mountingpositiononthewallandmarkthefourscrewhole locationsfortheassembly(seeFigure3).Notethateachof J1 J2 Cable themountingholesarekey-holeslottedtoallowtheassem- RJ48C/S RJ48C/S AccessHole Connector Connector bly to be mounted so the Customer Interface connections faceeitherleft,right,ordown. Figure5. RearViewof528-02I2 3. Drillthefourholesinthemountingsurface. andcustomerwiringandinstallingtheplug-inmodule(s)intothe 4. Lift theassembly and placethe528-02I2 baseplateonthe assembly. wall, aligning the holes in the base plate with the drilled holesinthemountingsurface. -INSPECTIONNOTE - 5. Insertthefirstmountingscrewintothetopleftholeinthe Visuallyinspecttheequipmentforsignsofdamageatthetimeofdelivery. baseplate,andtightenordrivethescrewuntilapproximate- Iftheequipmenthasbeendamagedintransit,immediatelyreporttheex- ly¼-inchremains. tentofthedamagetothetransportationcompanyandtoWestell(seePart 5fortelephonenumber). 6. Inserttheremainingthreescrewsandfastenuntilapproxi- mately¼-inchremains. CAUTION-STATIC-SENSITIVE 7. Carefully align, position, and hold the chassis in its final This product and the plug-in product installed inside the assembly positionandfinishdrivingthescrews.Tightenallscrews. may contain static-sensitive components! Proper electrostatic discharge procedures must be followed to maintain personal and -NOTE - equipmentsafety.Donotstoreunitsnearmagnetic,electromagnetic The528-02I2optionallymaybesetonatable,shelf,ordesk. orelectrostaticfields. Fordesktopinstallations,fourself-adhesiverubberfeetareprovidedand aretobeinstalledonthebottomoftheassemblytohelppreventmarring -PRECAUTIONARYSTATEMENT- thedesktopsurface. Neverinstalltelephonewiringduringalightningstorm. Never install telephone jacks in wet locations unless the jack is -CAUTION- specificallydesignedforwetlocations. Neverapplypoweruntilallinstallerconnectionsarecomplete. Never touch uninsulated telephone wires/terminals unless the telephonelineisdisconnectedatthenetworkinterface. Usecautionwheninstallingormodifyingtelephonelines. 3.4 ConnectingTelco/NetworkInterfaceCables Foruseinrestrictedaccesslocationsonly. Telcoornetworkinterfaceconnectionstotheassemblyaremade to one or both screw terminal blocks, TB1 and TB3, using 3.1 SelectingtheMountingLocation&Application shielded twisted pair cable (22-24 AWG minimum) of a length consistentwithlocalinstallationpractices.Ifonlyonemoduleis The 528-02I2 should be wall-mounted in accordance withlocal usedintheunit,insertitintothetop(upper)slotorpositionand practices.Theinstallationsiteshouldprovideadequatelighting useTB1forthenetworkconnections.Telco/networkconnection andequipmentaccess. Thedistancefromthe cableentry point pinnumbersarelistedinTable2. shouldbeconsistentwithlocalinstallationpractices.Allowade- quate clearance to accommodate the motion required by the -LIST9WIREWRAPPINNOTE - key-holeslots(¼-inch)whenlocatingtheassemblyforinstalla- The List 9 Option provides wirewrap pin connectors inside the unit for tion. Also ensure that adequate clearance (approximately 2 NetworkandCustomerconnections,insteadofscrewterminals.Substi- inches)isavailableforopeningthecover/doorandforinserting tutetheterm“wirewrappinheader”for“screwterminalblock”whenref- erencingthe528-02I2,List9. andremovingthemodule(s),whichslide(s)intoplaceinsidethe cover. CardEdgeConnector Teelco coTB1//TB33 P Posiittiion Function Pin# 3.2 GatheringtheMountingToolsandHardware ReceivefromNetwork 7 T Thetoolsrequiredtomounttheassemblyinclude: ReceivefromNetwork 13 R TransmittoNetwork 41 T1 S Flat-bladescrewdriver(toadjusttheterminalblockscrews and to adjust the mounting screws and ground lug) TransmittoNetwork 47 R1 Table2. TelcoInterfaceConnections S Wire strippers (for signal, power, and ground wires) 4 030-101584Rev.A R SectionDTW-A52-802-202 TYPICALFORBOTH CIRCUITS 7 T 7 5 8 RCV FROM T1 5 CKT#1 2 FAC R XMITTO 13 OR 1 15 CPE CKT#2 15 R1 RJ48S FACILITY OR CONNECTIONS CKT#3 OR CUSTOMER CONNECTIONS OR 2 55 T T1 55 41 CKT#4 1 XMTTO RCV FROM 5 CPE FAC R1 49 49 R 47 4 25 17 35 2 11 27 RJ48CORX J1--J4 FRAME GND LUG SWITCHTO CONFIGURE RJ48JACK FROM”C”TO ”S” ESDJACK (GRN)FRAME GND (BLK)+ PWR CKTGND LED1 (RED)--PWR CPE=Customer Premise Equipment. NET=Network equipment. Circuit #1 = the top slot when the table-top mounted unit is in the closed position (or left-most slot when wall mounted -- For 2--Wire HDSL/DS1, unit is open). CKT#1 Use FacilityTand R CKT#2 -- For 2--Wire HDSL/DS0, Use FacilityT1 and R1 SLOTPOSITIONS Figure6. 528-02I2FunctionalWiringDiagram Mounting CardEdgeConnector CIConnectorPosition/Pin TB5 F Function unction Pin Pin# # TB2 TB2 R RJJ48C 48C R RJJ48S 48S FRAME GND TB4 J1/J2 J1/J2 Optional* ReceivefromCPE 55 T 5 2 +PWR Ground Strap CKTGND ReceivefromCPE 49 R 4 1 Chassis -PWR TransmittoCPE 5 T1 2 7 Ground Lug To TransmittoCPE 15 R1 1 8 Lightning Return * See note at the Table3. CustomerInterfaceConnections To Ground Window (e.g., cold waterpipe) end of Table 4. Figure7. GroundingwithSpanPower 3.5 ConnectingCustomerInterfaceCables MakecustomerconnectionstoJ1andJ2(theRJ48C/Sjacks)or Local Mounting to one or both screw terminal blocks, TB2 and TB4, using PowerSupply TB5 shielded twisted pair cable (22-24 AWG minimum) of a length GND FRAME GND consistentwithlocalinstallationpractices.Ifonlyonemoduleis + +PWR usedintheassembly,insertitintothetop(upper)slotorposition Optional* and use connector J1 or TB2 for customer connections. See CKTGND Ground Chassis Strap Table3forpinnumbersandleaddesignations. -- Ground -PWR Lug Function TB5TerminalBlockLabel To Ground Window(e.g., cold waterpipe) To Lightning * See note at the Return Ground end of Table 4. -48VExt.PowerIn -PWR Figure8. GroundingwithLocalPower EarthGround FRAMEGROUND* LightningGroundReturn CIRCUITGND* +48VExt.PowerIn +PWR *Note:Forapplicationsrequiringchassisgroundtobeconnectedtocircuitground,anoptionalgroundstrapis provided for installation between the FRAME GND and CIRCUIT GND terminals on TB5. 3.7 SecuringCables Table4. PowerandGroundConnections After the assembly has been mounted and all wire connections have been made, use the four cable ties provided to secure all 3.6 ConnectingPowerandGround wires/cables. Themodule(s)inthe528-02I2canbespan/linepoweredorlocal- 3.8 InstallingModules lypoweredwithanexternal-48VDCpowersource.Localpower and ground connections to the assembly are made to TB5. See Table4 for power and ground connections. For applications Whenallwiringiscompletedandsecured,themodule(s)maybe where-48Vbulkpowerisnotreadilyavailable,Westelloffersa installed inside the assembly cover. Refer to the appropriate wall-mounted (plug-in) power supply, Model WPS4802 (115 practiceforoptioningandtestinginformationforeachmodule. VACto48VDC),thatcanbeorderedastheList6Optionforuse Whentestingiscompleteandthecircuitisfunctioningcorrectly, withthe528-02I2. closeandre-lockthecover(List4Option). 5 SectionDTW-A52-802-202 030-101584Rev.A R governing the sale of the product. Any attempt to repair or -CAUTION- modifytheequipmentbyanyoneotherthananauthorizedWest- Use care when installing and removing modules - do not force into ellrepresentativewillvoidthewarranty. place.Ifamoduleresistsinsertion,removeitandcheckfordebrisin orneartheconnectorandmountingslot.Gentlyre-insertthemodule. 6.2 RepairandReturn 4. TROUBLESHOOTING Westell will repair or replace any defective Westell equipment withoutcostduringthewarrantyperiodiftheunitisdefectivefor If trouble is encountered, verify all installer connections to the anyreasonotherthanabuse,improperuse,orimproperinstalla- assembly and check that the CO power fuse is not blown. Also tion. Before returning the defective equipment, first request a verify all module connections and option switch settings, and Return Material Authorization (RMA) number from Westell. verify the modules are making a positive connection with the Once an RMA number is obtained, return the defective unit, shelfconnector.Iftroublepersists,replacethesuspectassembly freightprepaid,andabriefdescriptionoftheproblem,to: and repeat procedures outlined. These procedures are not de- Westell,Inc. signed to effect repairs or modifications. Procedures beyond thoseoutlinedhereinorrepairsmadebeyondreplacingafaulty ATTN:R.G.M.Department assemblyarenotrecommendedandmayvoidthewarranty. 880EnterpriseSt. SuiteD Aurora,IL60504-7940 5. CUSTOMER&TECHNICALSERVICES Replacements will be shipped in the fastest manner consistent 5.1 CustomerService&TechnicalAssistance withtheurgencyofthesituation.Westellwillcontinuetorepair or replace faulty equipment beyond the warranty period for a Iftechnicalorcustomerassistanceisrequired,contactWestellby nominalcharge.ContactWestellfordetails. callingorusingoneofthefollowingoptions: Voice: (800)377-8766 7. SPECIFICATIONS email: global_support@westell.com To order assemblies, call a telephone number shown in Para- VisittheWestellWorldWideWebsiteathttp://www.Westell.com graph5.1andpleasespecifytheassemblyorderinginformation foradditionalinformationaboutWestell. showninTable 6.Theelectricalandphysicalspecificationsare showninTable 5. 5.2 PartNumbers PhysicalFeature U.S. Metric This equipment is identified by a model number and an issue Height 3.25in. 8.3cm number. Each time a change is made to the product which Width (including door) 5.75in. 14.6cm changestheform,fit,orfunctionoftheproduct,theissuenum- ber is incremented or advanced by one. Be sure to indicate the Depth (incl. ground lug) 9.25in. 23.5cm issuenumberaswellasthemodelnumberwhenmakinginquiries Weight (empty, approx.) 3.1lb. 1.4Kg abouttheequipment. OperatingTemp. --40°Fto149°F --40°to65°C Humidity 0to95%(non-condensing) 6. WARRANTY&REPAIRS ElectricalFeature Description InputPower -42to-56VDC,orsimplexlinepower 6.1 Warranty Outputpowertoplug-ins -42to-56VDC,orsimplexlinepower Westellwarrantsthisproducttobefreeofdefectsatthetimeof NEBSLevel3andUL60950certificationbyanNRTL shipment.Westellalsowarrantsthisproducttobefullyfunction- Table5. Specifications al for the time period specified by the terms and conditions FAC CPE Connections Connections Wire Screw Screw Locking ModelNumber CLEICode RJ48C/S Power Wrap Term Term Cover DTWA528--02I2 VAM7ZB0ARA X X X DTWA528--02I2L4 VAM72B0ARA X X X X DTWA528--02I2L6 X X X WPS--4802 DTWA528--02I2L4--6 X X X X WPS--4802 DTWA528--02I2L4--9 VAM74B0ARA X X X DTWA528--02I2L4--6--9 X X X WPS--4802 DTWA528--02I2L4--7--9 X X X A90--204100 * CLEIisatrademarkof TelcordiaTechnologies. Table6. OrderingandOptionInformation 6

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the DTWA-528-0212 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

UNIV MTG ASBY WW

UNIV MTG ASBY WW

UNIV MTG ASBY WW PW LC

UNIV MYG ASBY WW PW

4W SS UNIV NET INT PWR

product

Westell DBMA200-03FA 3-Postion, non-locking DS3 Mounting