VMIC VMIACC-5595

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number VMIACC-5595
Manufacturer VMIC
Category ACC
Price Request Quote
Lead Time Request Quote

Description

VMIC VMIACC-5595 Hub -2 Gb/s Reflective Memory Hub Assembly For use with VMIC's Embedded Systems’ VMIxxx-5565 Reflective Memory network of products

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Elite.Parts is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a VMIACC-5595? We can help you find it at a competitive price!

Specifications

Operating Humidity Relative humidity 20% to 80%, non condensing
Operating Temperature 0° to +65° C
Storage Humidity Relative humidity 20% to 80%, non condensing
Storage Temperature -40° to +85° C

Features

  • 10BaseT Ethernet TCP/IP port for remote access and control
  • Automatic bypass can be optionally controlled by the loss of
  • Automatically bypasses defective or disconnected nodes in a fiber-optic network
  • Configurable for use with cables up to 10km in length
  • Dark on Dark option turns off the board’s transmitter if the receiver does not detect a signal (available for firmware versions 02.00 and later)
  • Each port regenerates the serial optical signal, eliminating link losses and reducing jitter
  • For use with GE Fanuc Embedded Systems’ VMIxxx-5565 Reflective Memory network of products
  • Hub assemblies can be cascaded with a maximum of 256 nodes
  • Internal universal power supply
  • Optional 19-inch 1U rack mount or desktop enclosure
  • Provides up to eight ports using small form factor pluggable (SFP) transceivers
  • RS232 port for local access and control
  • signal or by the loss of sync pattern

Datasheet

Download "GE_Datasheet_vmiacc556-4814447885.pdf" (172 KiB)

Extracted Text

GE Fanuc Automation VMIACC-5595 Specification 2 Gb/s Reflective Memory Hub Assembly Features: • For use with GE Fanuc Embedded Systems’ VMIxxx-5565 Reflective Memory network of products • Provides up to eight ports using small form factor pluggable (SFP) transceivers • Hub assemblies can be cascaded with a maximum of 256 nodes • Automatically bypasses defective or disconnected nodes in a fiber-optic network • Automatic bypass can be optionally controlled by the loss of signal or by the loss of sync pattern • Each port regenerates the serial optical signal, eliminating link losses and reducing jitter • Configurable for use with cables up to 10km in length • 10BaseT Ethernet TCP/IP port for remote access and control • RS232 port for local access and control • Optional 19-inch 1U rack mount or desktop enclosure • Internal universal power supply • Dark on Dark option turns off the board’s transmitter if the receiver does not detect a signal (available for firmware versions 02.00 and later) VMIACC-5595 2Gb/s Reflective Memory Hub Assembly (long distance) transceivers. This feature permits a cost saving in Ordering Options small networks as well as system optimization. For larger May 16, 2007 800-805595-000 E A B C networks, several VMIACC-5595 assemblies can be cascaded, permitting a managed hub array with up to 256 nodes. Each VMIACC-5595 port regenerates the serial optical signal, eliminating the A = Enclosure Options problems with insertion losses and cable attenuation. Signal 0 = Reserved regeneration also reduces jitter. The RS232 port gives you the 1 = Reserved 2 = Rack Mount or Desktop ability to monitor and control your Reflective Memory network B = Number of Single-Mode (10km) Pluggable Transceivers through a simple PC serial port. The Ethernet port feature allows 0, 1, 2, 3, 4, 5, 6, 7, or 8 you to monitor and control the hub from great distances C = Number of Multimode Pluggable Tranceivers through a local area network (LAN) or via a Web browser. 0, 1, 2, 3, 4, 5, 6, 7, or 8 Simplex Cable Specifications As an option, the VMIACC-5595 can be configured as a 19-inch 1U rack-mountable enclosure or as a desktop enclosure. The Fiber-Optic Cable – Multimode 62.5 Micron core universal power supply permits operation with nearly any Fiber-Optic Cable Assemblies A B C international power standard. VMICBL-000-F5 Product Overview ABC = Cable Lengths 000 = 0.5 ft (01.5m) 009 = 200 ft (60.98m) The VMIACC-5595 automatically bypasses ports when the 001 = 1 ft (0.31m) 010 = 250 ft (76.20m) absence of valid synchronization patterns is detected. Three 002 = 5 ft (1.52m) 011 = 350 ft (106.68m) LEDs, adjacent to each port, provide a visual indication of the 003 = 10 ft (3.04m) 012 = 500 ft (152.15m) port status. Additional status indications and modes of 004 = 25 ft (7.62m) 013 = 574 ft (175m) 005 = 50 ft (15.24m) 014 = 656 ft (200m) operation are available through either the serial port or the 006 = 80 ft (24.40m) 016 = 1,000 ft (304.30m) Ethernet port. 008 = 150 ft (45.72m) Duplex Cable Specifications Status information includes the detection of installed transceivers, the detection of signal (light), the detection of valid Fiber-Optic Cable - Multimode; 62.5 Micron core. synchronization patterns and the port operation speed (2Gb/s). Fiber-Optic Cable Assemblies A B C Control registers allow the channel bypass to be based on the absence of a single valid synchronization pattern or multiple VMICBL-000-F6 synchronization patterns. A bypass can also be based simply on ABC = Cable Lengths the loss of a signal (light). In addition, each port can be manually 000 = 3 ft (1m) 011 = 426 ft (130m) forced either active or bypassed regardless of the status 001 = 6 ft (2m) 012 = 492 ft (150m) 002 = 10 ft (3m) 013 = 557 ft (170m) indicators. 003 = 16 ft (5m) 014 = 656 ft (200m) 004 = 32 ft (10m) 015 = 721 ft (220m) An additional control register permits the transmitter of any port 005 = 66 ft (20m) 016 = 754 ft (230m) to be manually disabled. 006 = 98 ft (30m) 017 = 820 ft (250m) 007 = 164 ft (50m) 018 = 885 ft (270m) Front panel manual switches include a recessed momentary 008 = 230 ft (70m 019 = 984 ft (300m) reset switch and a Gang Select switch. The Gang Select switch 009 = 328 ft (100m) 020 = 1 ft (0.3048m) configures the VMIACC-5595 ports as one loop of eight ports or 010 = 393 ft (120m) two separate loops of four ports each. Note The sum of B + C + D Modules should be less or equal to 8. Functional Characteristics For Ordering Information, Call: Multimode Port Wavelength: 830 to 860nm 1-800-322-3616 or 1-256-880-0444 • FAX (256) 882-0859 Email: info.embeddedsystems@gefanuc.com Multimode Cable Length: 300m (maximum) Web Address: www.gefanucembedded.com Copyright © 2007 by GE Fanuc Embedded Systems Single-Mode (10km) Port Wavelength: 1,300 to 1,335nm Specifications subject to change without notice. Single-Mode (10km) Cable Length: 10km (maximum) Single-Mode (80km) Port Wavelength: 1,540 to 1,570nm Introduction The VMIACC-5595 is a managed hub designed to operate with Single-Mode (10km) Cable Length: 80km (maximum) the GE Fanuc Embedded Systems’ VMIxxx-5565 family of Dark on Dark: The Dark on Dark option turns off the board’s Reflective Memory real-time network products. The Reflective transmitter if the receiver does not detect a signal (available for Memory hub can automatically bypass ports when it detects a firmware versions 02.00 and later). loss of signal or the loss of valid synchronization patterns, allowing the other nodes in the network to remain operational. Ethernet Controller: 10BaseT interface is compliant with Since the optical ports are implemented with small form factor Transmission Control Protocol/Internet Protocol (TCP/IP) pluggable (SFP) transceivers, only the required ports need to be standards. Each hub assembly will have a unique MAC address. populated. The VMIACC-5595 SFP transceivers can be a The hub assembly can operate on either a LAN or a wide area combination of either multimode (short distance) or single-mode network (WAN). 2 VMIACC-5595 2Gb/s Reflective Memory Hub Assembly The VMIACC-5595 includes a remote user interface available Fuse: 1A, 250V, 5 x 20 mm, fast acting, IEC 60127-2 standard through a standard Ethernet connection. The remote interface is glass or equivalent controlled by the use of standard HTML-based Web browsers. Temperature: The user interface presents status data, such as “loss of signal” Operating: 0° to +65° C and “sync detect” information. Bypass mode, “Dark on Dark’ and Storage: -40° to +85° C the ability to force each port on/off or automatic are supported. Humidity: These settings are retained in NVRAM. Operating: Relative humidity 20% to 80%, noncondensing Storage: Relative humidity 20% to 80%, noncondensing Physical/Environmental Specifications MTBF: Total fit x qty: 2,317.3641 Desktop Assembly Dimensions: 16.73 inches wide by MTBF (hours): 431,524.76 10.0 inches deep by (1U) 1.72 inches high. Dimensions do not include nonskid self-adhesive feet. Regulatory: GE Fanuc Embedded Systems has planned testing of the VMIACC-5595 to meet the following standards, where Rack Mount Assembly Dimensions: The basic dimensions are applicable: the same as the desktop assembly, but include two 1U rack mount brackets for the standard 19-inch rack. European Union (CE Mark) EN55024 Front Panel Connectors: There are eight industry-standard SFP EN55022 Radiated Emissions Class A transceivers. The SFP receptacles not populated with EN55022 Conducted Emissions Class A transceivers contain EMI dust plugs. There is one RJ45 Ethernet EN61000-4-2 (ESD) connector and one 9-pin female D-subminiature RS232 EN61000-4-3 (Radiated Immunity) connector. EN61000-4-4 (EFT) Cabling: Each installed SPF transceiver requires either one EN61000-4-5 (Surge) Duplex LC-type fiber-optic cable or two Simplex LC-type EN61000-4-6 (Conducted RF) fiber-optic cables. The Simplex cables are best suited for EN61000-4-8 (Power Frequency Magnetic Fields) cascading hubs. The Duplex cables can be used for all other United States interconnectivity. FCC Part 15, Class A Rear Panel Connectors: The rear panel contains a power entry Canada module that includes a power ON/OFF switch, a 4A/250V fuse, ICES-003, Class A and a globally accepted IEC receptacle. Power Requirements: Safety: The VMIACC-5595 has been designed to meet the following safety standards where applicable: 90 to 264VAC, 47 to 440Hz, 25W. UL60950 Power supply and power entry module meet safety standards: EN60950(LVD) UL, C-UL: UL 1950 TUV: EN69050 Trademarks CE: EN55022, EN61000-4-2, 3, 4, 5; EN61000-3-2 All registered trademarks are the property of their respective owners. 3 VMIACC-5595 2Gb/s Reflective Memory Hub Assembly Figure 1. VMIACC-5595 Functional Block Diagram 4 VMIACC-5595 2Gb/s Reflective Memory Hub Assembly Figure 2. Example: Cascade of Three VMIACC5595s with 24 Nodes GE Fanuc Embedded Systems Information Centers Additional Resources Americas: For more information, please visit the Huntsville, AL 1 800 322-3616 GE Fanuc Embedded Systems web site at: 1 (256) 880-0444 www.gefanucembedded.com Camarillo, CA 1 (805) 987-9300 Greenville, SC 1 (864) 627-8800 Richardson, TX 1 (972) 671-1972 Europe, Middle East and Africa: Edinburgh, UK 44 (131) 561-3520 Paris, France 33 (1) 4324 6007 5

Related Products

VMIC
VMIC VMIACC-0130 P2 Power Adapter Accessory for the VMIVME-1129
VMIC
VMIC VMIACC-0320 CompactPCI Rear Transition Utility Board for the VMICPCI-7...
VMIC
VMIC VMIACC-0502 502 and 506 Polarizing Bars for DIN 41612 Connectors
VMIC
VMIC VMIACC-344x Transition Panels with Surge Withstand Protection
VMIC
VMIC VMIACC-AD242X OPTO 22 Digital I/O Cable Adapter Boards

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Elite.Parts are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Elite.Parts is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.052 seconds.