VERIS INDUSTRIES 735

Description
Veris Industries 735 Accessory - CURRENT SENSOR 24VAC/DC HAWKEYE
Part Number
735
Price
Request Quote
Manufacturer
VERIS INDUSTRIES
Lead Time
Request Quote
Category
PRODUCTS - 7
Specifications
Amperage Range
1-135A continuous
Frequency Range
50/60Hz
Humidity Range
10-90% RH non-condensing
Hysteresis
10% of setpoint, typical
Insulation Class
600VAC rms (UL)
Off-State Leakage
1+ MO
Output
N.O. 0.1A@30VAC/DC, polarity insensitive
Relay Coil
24VAC/DC 10mA
Relay Contact
5A@250VAC/DC, 3A@30VDC, 1/6 hp
Safety
UL 508, CAT III
Sensor Power
Induced from monitored current
Temperature Range
-15° to 60°C (5° to 140°F)
Datasheet
Extracted Text
VERIS INDUSTRIES CURRENT MONITORING INSTALLATION GUIDE ™ TM H735 735 Solid-Core Current Switch, Adjustable Output, with Command Relay Installer’s Specifications Sensor Power Induced from monitored current Insulation Class 600VAC rms (UL) Frequency Range 50/60Hz Relay Coil 24VAC/DC 10mA Relay Contact 5A@250VAC/DC, 3A@30VDC, 1/6 hp Temperature Range -15° to 60°C (5° to 140°F) Humidity Range 10-90% RH non-condensing Amperage Range 1-135A continuous Output N.O. 0.1A@30VAC/DC, polarity insensitive Hysteresis 10% of setpoint, typical Off-State Leakage 1+ MΩ Safety UL 508, CAT III Do not use the LED status indicators as evidence of applied voltage. The product design provides for basic insulation only. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH quick install • Follow safe electrical work practices. See NFPA 70E in the USA, or applicable local codes. • This equipment must only be installed and serviced by qualified electrical personnel. 1. Disconnect and lock out power. • Read, understand and follow the instructions before installing this product. • Turn off all power supplying equipment before working on or inside the equipment. 2. Install the mounting bracket to the back of the electrical enclosure, no closer than • Use a properly rated voltage sensing device to confirm power is off. 1/2” (12mm) to an uninsulated conductor. DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATION • Only install this product on insulated conductors. 3. Slide the conductor to be monitored through the sensing hole of the current switch. Terminate the conductor. See Notes (page 2) for currents under 1 Amp or Failure to follow these instructions will result in death or serious injury. above 135 Amps. 4. Wire the output connections to the DDC controller or switched load. Note: NOTICE Contacts are solid state and work like dry contacts. When the switch is closed, less than 1 Ω is present. When the switch is open, more than 1 MΩ are present. • This product is not intended for life or safety applications. • Do not install this product in hazardous or classified locations. 5. Reconnect power. • The installer is responsible for conformance to all applicable codes. • Mount this product inside a suitable fire and electrical enclosure. 6. Calibrate the sensor (see Calibration section). Wiring ExamplE DimEnsions Removable/Adjustable Mounting Bracket CONTROLLER 0.9" DI (Status) (23 mm) 0.7" Dia (19 mm) DO (Relay 3.0" Coil) (75 mm) 2.8" (68 mm) 1.1" CONTACTOR (27 mm) Fan or Pump 0.2” x 0.15” 3.8" slot (2x) (95 mm) CONTROL 4.2" POWER (106 mm) Motor Z201486-0H PAGE 1 ©2010 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 08101 Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries. VERIS INDUSTRIES INSTALLATION GUIDE H735 ™ opEration calibration Before beginning calibration, establish normal load conditions. The H735 is a current-sensitive switching device with integral command relay that OK! monitors current (amperage) in the conductor passing through it. A change in amperage in the monitored conductor that crosses the switch (setpoint) threshold A plus the hysteresis value will cause the resistance of the status output to change Then choose either A or B below. state, similar to the action of a mechanical switch. This status information can be fed back to a building controller that interprets the signal and separately switches the A. To monitor under-current (belt loss, coupling shear, status) relay. The status output can also be used to switch the relay directly. STATUS ! OK! OK! A In this model, the setpoint is adjustable through the action of a twenty (20) turn potentiometer (see the CALIBRATION section). The status output is suitable for Status 1. Turn setpoint screw connection to building controllers or other appropriate data acquisition equipment Open Setpoint clockwise until Status OPEN operating at up to 30 volts. The H735 relay requires a 24VAC/VDC external power LED turns ON. supply for operation. STOP notEs For load currents greater than sensor maximum rating: 2. Slowly turn the screw counter-clockwise until the Status CLOSED LED just Use a 5 Amp (H68xx series) Current Transformer (CT) as shown. turns ON. 3.Turn the screw an Setpoint Status Setpoint Closed additional 1/4 turn 240A > 135A (Sensor max.) counter-clockwise for + operational margin. 1/4 STOP 300A:5A B. To monitor over-current (mechanical problems, seized impeller) STATUS H68xx-5A CT ! OK! OK! A DANGER: 5A CTs can present hazardous voltages. 1.Turn setpoint screw Status Install CTs in accordance with manufacturer's instructions. Setpoint Closed counter-clockwise until Status Terminate the CT secondary before applying current. CLOSED LED turns ON. STOP CAUTION 2. Slowly turn the setpoint screw clockwise until the Status OPEN LED just turns ON. RISK OF EQUIPMENT DAMAGE Status • Derate the product’s maximum current for the number of turns Setpoint Open 3. Turn the setpoint Setpoint through the sensing window using the following formula. + screw an additional Rated Max. Amps ÷ Number of Turns = Max. monitored Amps 1/4 turn clockwise for e.g. : 100A ÷ 4 Turns = 25 Amps max. in monitored conductor STOP operational margin. 1/4 • Failure to follow these instructions can result in overheating and permanent equipment damage. troublEshooting Problem Solution For load currents less than sensor minimum rating: No Reading at Controller • Check sensor calibration (see above) Wrap the monitored conductor through the center hole and around the sensor body • Check for control voltage at sensor (<30V) to produce multiple turns through the "window." This increases the current measured • Check for amperage in monitored conductor (> 1A) by the transducer. • Assure that sensor core mating surfaces are clean and < 1 A (Sensor Min.) that the core clamp is completely closed Controller must be 4x programmed to account for the Setpoint screw has no stops The setpoint screw has a slip-clutch at both ends of its 0.5A travel to avoid damage. Twenty turns CCW will reset extra turns. e.g., if four turns the sensor to be most sensitive. Repeat calibration pass through the sensor (as above. shown) the normal controller Both LEDs are lit Setpoint screw is too far clockwise. See solution above. reading must be divided by 4. Relay chatters or will not change • Check voltage at relay coil (<24VAC/DC) state • Parallel applications with AC transformers can damage the relay. Z201486-0H PAGE 2 ©2010 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 08101 Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris ‘V’ logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries. OK!
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the 735 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods