Elite.Parts Manufacturers T TOKO AMERICA VRW
About product Datasheet FAQ

TOKO AMERICA VRW

Image of TOKO AMERICA VRW

Description

Toko America VRW Series Power Supplies

Part Number

VRW

Price

Request Quote

Manufacturer

TOKO AMERICA

Lead Time

Request Quote

Category

PRODUCTS - V

Datasheet

pdf file

Toko-America-VRW-Series-Power-Supply-datasheet1-2069515644.pdf

193 KiB

Extracted Text

Benign Environment AC-DC Converters >100 W VRW-Family 150/200/300/450 W AC-DC Converters VRW-Family Single output • Universal AC input (VRW 200, VRW 300, VRW 450) • 3000 V input to output isolation rms • Compact design • Excellent line/load regulation • High efficiency Safety according to IEC 950 Table of Contents Page Type Survey ............................................................ 11 - 99 Operation Instructions ........................................... 11 - 104 Description .............................................................. 11 - 99 Mounting Instructions ............................................ 11 - 105 Safety and Installation Instructions ....................... 11 - 100 Immunity to Environmental Conditions .................. 11 - 106 Electromagnetic compatibility EMC....................... 11 - 100 Type Key and Product Marking ............................. 11 - 106 Electrical Input and Output Data ........................... 11 - 101 Mechanical Data, Input and Output Terminals ...... 11 - 107 Type Survey Table 1: Type survey Output configuration Input voltage Rated power Type designation U I range P Open frame Chassis cover o nom o nom o tot [V DC] T = 40°C [A] U ...U T = 40°C [W] A i min i max A 3 40 120 VRW 200-03 VRW 200-03A 60 180 VRW 300-03 VRW 300-03A 5 30 150 VRW 150-05 VRW 150-05A 40 VRW 150: 200 VRW 200-05 VRW 200-05A 60 85...132 V AC 300 VRW 300-05 VRW 300-05A 90 or 170...265 V AC 450 VRW 450-05 VRW 450-05A 47...440 Hz 12 13 150 VRW 150-12 VRW 150-12A 230...330 V DC 19 200 VRW 200-12 VRW 200-12A jumper selectable 26 300 VRW 300-12 VRW 300-12A 40 450 VRW 450-12 VRW 450-12A 15 10 150 VRW 150-15 VRW 150-15A 15 200 VRW 200 -15 VRW 200-15A 21 300 VRW 300-15 VRW 300-15A VRW 200, VRW 300 32 450 VRW 450-15 VRW 450-15A VRW 450: 24 6.5 85...265 V AC 150 VRW 150-24 VRW 150-24A 9 47...63 Hz 200 VRW 200-24 VRW 200-24A 13 PF = 0.95 300 VRW 300-24 VRW 300-24A 20 450 VRW 450-24 VRW 450-24A 28 4.5 150 VRW 150-28 VRW 150-28A 48 3.2 150 VRW 150-48 VRW 150-48A Description The VRW family of switching power supplies is a single out- Key applications put family of AC-DC converters. Compact size and high re- Factory automation, test and measurement, point-of-sales liability make the VRW family an excellent choice. Five and communications equipment. standard single output ratings are available. All types have sense lines, the VRW 300 and VRW 450 provide also for inhibit function. The units are UL 1950(D3), CSA 1402C und EN 60950 approved. Edition 2/96 - © Melcher AG MELCHER 11 - 99 The Power Partners. 11.3 VRW-Family AC-DC Converters >100 W Benign Environment Safety and Installation Instructions Safety Installation instruction If the output circuit of an AC-DC converter is operator-ac- Installation of the power supply must strictly follow the na- cessible according to the IEC 950 related safety standards, tional safety regulations. To observe the safety require- it shall be an SELV circuit (Safety Extra Low Voltage circuit, ments according to EN 60950/IEC 950, the module shall be i.e. a circuit, separated from mains by at least basic insula- connected via the female connector or terminal block. tion, that is so designed and protected that under normal Other installation methods may not meet the safety require- and single fault conditions, the voltage between any two ments. At least one external fuse, installed in the wiring to conductors and between any conductor and earth does not the input is essential! exceed 60 V DC). In the following section an interpretation is provided of the IEC 950 safety standard with respect to the safety status of the output circuit. However, it is the sole responsibility of the installer or user to assure the compliance with the relevant and applicable safety standards: If the AC-DC converter is installed acoording to the relevant safety regulations, its output is considered to be an SELV circuit up to a nominal output voltage of 36 V, provided the output is connected to ground according to the relevant safety standard, a suitable input line fuse is installed and an adequate voltage limiting device is connected across the output. Electromagnetic compatibility EMC Immunity A metal oxide VDR together with an input fuse and an input but especially in battery driven mobile applications. The filter form an effective protection against high input tran- VRW family has been successfully tested to the following sient voltages which typically occur in most installations, specifications: Table 2: Immunity type tests Phenomenon Standard Class Coupling Value Waveform Source Test In Per- 3 Level mode applied Imped. procedure oper. form. 1 Electrostatic IEC 801-2 4 air discharge 15 kV 1/50 ns 330 Ω 10 positive and yes p discharge (1991-04) to frame 10 negative discharges 1 Fast transient/ IEC 801-4 3 i/c, +i/–i 2000 V 5/50 ns 50 Ω 1 min positive yes p burst (1988) 1 min negative bursts per coupling mode 21 Transient IEC 801-5 4 i/c 4000 V 1.2/50 μs 12 Ω 5 pos. and 5 neg. yes p (Draft 1993-01 ) impulses per coupling mode 1 Normal operation, no deviation from specifications 2 No load 3 i = input, o = output, c = case Emission Suitable input filtering keeps the conducted noise of the units within the frequency range of 10 kHz to 30 MHz below level B according to EN 55011 and EN 55022 standards (CISPR 11/22 respectively). In some applications, it may be necessary to add an external input filter to reach level B. Refer also to table "Input Data". 11 - 100 MELCHER Edition 2/96 - © Melcher AG The Power Partners. 11.3 Benign Environment AC-DC Converters >100 W VRW-Family Electrical Input and Output Data General Condition: T = 25°C unless otherwise specified A Table 3: Input data Characteristics VRW 150-.. VRW 200-.. VRW 300-.. VRW 450-.. Unit U Rated input voltage 100-120/200-240 100-120/200-240 V AC i rated 1 U Input voltage range 85...132/170...265 85...265 i 2 230...330 –V DC f Line frequency 47...440 47...63 Hz i 3 I Input current 100/200 V AC 3.2/1.7 3.0/1.5 4.0/2.0 6.2/3.1 A i 3 l Inrush current 100/200 V AC 15/30 14.0/28.0 14/28 14/28 inr 3 PF Power Factor – 0.95 3 I Leakage current 100/200 V AC 0.25/0.40 0.6/0.4 0.6/0.4 0.8/0.4 mA i leak U Input RFI level EN 55011/22 B B B B i RFI 1 Jumper selectable. 2 Terminals A and B not connected. 3 At rated input and output. General Condition: T = 25°C unless otherwise specified A Table 4a: Output data 150 W types Type VRW 150-05 VRW 150-12 VRW 150-15 Characteristics Unit U Output voltage nom. 5 12 15 V o nom U Adjustable voltage range ±10 % o adj I Rated output current 30 13 10 A o nom I Output current range min./max. 0...100 % o 1 u Ripple-noise max. 120 150 150 mVpp o ΔU Line regulation U ...U ±0.4 % o U i min i max ΔU Load regulation 0...100% ±0.8 o I αu Temperature coefficient max. ±1 o 2 I Overcurrent protection 105 o L 3 U Overvoltage protection 5.75...6.75 13.8...16.2 17.3...20.3 V o L 1 t Rise time typ. 20 ms Uo r 1 t Hold-up time typ. 20 h 1 η Effciency typ. 78 80 82 % Output indicator not provided Outputs connected in series possible Outputs connnected in parallel not possible Remote sensing possible Remote shut-down not possible 1 At rated input and output. 2 Operating in foldback method, automatic recovery. Overload for more than 30 seconds should be avoided. 3 Shut down of output. Turn-on by brief removal of the input voltage. Overvoltage protection is not adjustable. Edition 2/96 - © Melcher AG MELCHER 11 - 101 The Power Partners. 11.3 VRW-Family AC-DC Converters >100 W Benign Environment General Condition: T = 25°C unless otherwise specified A Table 4b: Output data 150 W types Type VRW 150-24 VRW 150-28 VRW 150-48 Characteristics Unit U Output voltage nom. 24 28 48 V o nom U Adjustable voltage range ±10 % o adj I Rated output current 6.5 4.5 3.2 A o nom I Output current range min./max. 0...100 % o 1 u Ripple-noise max. 150 150 200 mVpp o ΔU Line regulation U ...U ±0.4 % o U i min i max ΔU Load regulation 0...100% ±0.8 o I αu Temperature coefficient max. ±1 o 2 I Overcurrent protection 105 o L 3 U Overvoltage protection 27.6...32.4 32.2...37.8 55.2...64.8 V o L 1 t Rise time typ. 20 ms Uo r 1 t Hold-up time typ. 20 h 1 η Effciency typ. 84 84 84 % Output indicator not provided Outputs connected in series possible Outputs connnected in parallel not possible Remote sensing possible Remote shut-down not possible 1 At rated input and output. 2 Operating in foldback method, automatic recovery. Overload for more than 30 seconds should be avoided. 3 Shut down of output. Turn-on by brief removal of the input voltage. Overvoltage protection is not adjustable. General Condition: T = 25°C unless otherwise specified A Table 4c: Output data 200 W types Type VRW 200-05 VRW 200-12 VRW 200-15 VRW 200-24 Characteristics Unit U Output voltage nom. 5 12 15 24 V o nom U Adjustable voltage range ±10 % o adj I Rated output current 40 19 15 9 A o nom I Output current range min./max. 0…100 % o 1 u Ripple-noise max. 150 180 180 240 mVpp o ΔU Line regulation U …U ±0.4 % o U i min i max ΔU Load regulation 0…100% ±0.8 o I αu Temperature coefficient max. ±1 o 2 I Overcurrent protection 42.0...50.0 19.9...23.7 15.7...18.7 9.4...11.2 A o L 3 U Overvoltage protection 6.0…7.0 14.4…16.8 18.0…21.0 28.0…32.0 V o L 1 t Rise time typ. 20 ms Uo r 1 t Hold-up time typ. 20 h 1 η Effciency typ. 75 77 78 81 % Output indicator not provided Outputs connected in series possible Outputs connnected in parallel not possible Remote sensing possible Remote shut-down possible 1 At rated input and output. 2 Operating in foldback method, automatic recovery. Overload for more than 30 seconds should be avoided. 3 Shut down of output. Turn-on by brief removal of the input voltage. Overvoltage protection is not adjustable. 11 - 102 MELCHER Edition 2/96 - © Melcher AG The Power Partners. 11.3 Benign Environment AC-DC Converters >100 W VRW-Family General Condition: T = 25°C unless otherwise specified A Table 4d: Output data 300 W types Type VRW 300-05 VRW 300-12 VRW 300-15 VRW 300-24 Characteristics Unit U Output voltage nom. 5 12 15 24 V o nom U Adjustable voltage range ±10 % o adj I Rated output current 60 26 21 13 A o nom I Output current range min./max. 0…100 % o 1 u Ripple-noise max. 150 180 180 240 mVpp o ΔU Line regulation U …U ±0.4 % o U i min i max ΔU Load regulation 0…100% ±0.8 o I αu Temperature coefficient max. ±1 o 2 I Overcurrent protection 63.0...75.0 27.3...32.5 22.1...26.2 13.7...16.2 A o L 3 U Overvoltage protection 6.0…7.0 14.4…16.8 18.0…21.0 28.0…32.0 V o L 1 t Rise time typ. 50 ms Uo r 1 t Hold-up time typ. 20 h 1 η Effciency typ. 76 78 78 82 % Output indicator not provided Outputs connected in series possible Outputs connnected in parallel not possible Remote sensing possible Remote shut-down possible 1 At rated input and output. 2 Operating in foldback method, automatic recovery. Overload for more than 30 seconds should be avoided. 3 Shut down of output. Turn-on by brief removal of the input voltage. Overvoltage protection is not adjustable. General Condition: T = 25°C unless otherwise specified A Table 4e: Output data 450 W types Type VRW 450-05 VRW 450-12 VRW 450-15 VRW 450-24 Characteristics Unit U Output voltage nom. 5 12 15 24 V o nom U Adjustable voltage range ±10 % o adj I Rated output current 90 40 32 20 A o nom I Output current range min./max. 0…100 % o 1 u Ripple-noise max. 150 180 300 400 mVpp o ΔU Line regulation U …U ±0.4 % o U i min i max ΔU Load regulation 0…100% ±0.8 o I αu Temperature coefficient max. ±1 o 2 I Overcurrent protection 94.5...103.5 42.0...46.0 33.6...36.8 21.0...23.0 A o L 3 U Overvoltage protection 6.0…7.0 14.4…16.8 18.0…21.0 28.0…32.0 V o L 1 t Rise time typ. 50 ms Uo r 1 t Hold-up time typ. 20 h 1 η Effciency typ. 76 78 78 82 % Output indicator not provided Outputs connected in series possible Outputs connnected in parallel not possible Remote sensing possible Remote shut-down possible 1 At rated input and output. 2 Operating in foldback method, automatic recovery. Overload for more than 30 seconds should be avoided. 3 Shut down of output. Turn-on by brief removal of the input voltage. Overvoltage protection is not adjustable. Edition 2/96 - © Melcher AG MELCHER 11 - 103 The Power Partners. 11.3 VRW-Family AC-DC Converters >100 W Benign Environment P [%] O Operation Instructions VRW 150: AC Input Voltage Range Selection 100 The AC input voltage range can be selected by means of wiring at the connector barrier as per the following table: Table 5: Input voltage range selection 60 Input voltage range Terminals A and B 50 85...132 V AC interconnected VRW 150 170...265 V AC open 230...330 V DC (not connected) VRW 200/VRW 300/VRW 450 Output Power Rating 0 T A The relation between the rated output power P and the o –20 –1003 10 200 40 50 60 70 [°C] ambient temperature T is shown in fig. 1. A Fig. 1: Output Voltage Adjustment Output power vs. ambient temperature The output voltage may be adjusted within ±10% of U o nom by means of the internal potentiometer. If the output voltage Outputs Connected in Parallel setting should be excessively high, the overvoltage protec- Parallel connection of several identical modules is not pos- tion circuit may shut-down the output. sible. Output Overvoltage Protection Inhibit (R, VRW 200, VRW 300 and VRW 450 series) If the built-in overvoltage protection circuit becomes active, The output may be enabled or disabled by means of a logic the output is shut down and a reset can only be achieved by signal (TTL, CMOS etc.) or a mechanical contact applied to brief removal of the input voltage after a minimum interval the inhibit input which is isolated from input and output by time. The overvoltage threshold level is not adjustable. means of an opto-coupler. This provides independency from other voltages polarity. If the inhibit function is not re- Output Overload Protection quired, connect the inhibit input +R to return pin -R to en- An overload condition at the output should not last for more able the output (active low logic, fail safe). than 30 seconds. After removal of the overload, the over- load protection circuit will automatically recover. L I +R inh Sense Lines (S, VRW 200, VRW 300, VRW 450 series) Remote sensing provides compensation of voltage drops U inh between power supply and load, caused by connectors and N -R load feeding wires. The sense lines should consist of shielded cables or be twisted. If remote sensing is not Fig. 2 reqiured, the +S should be connected to the +V and the –S Definition of inhibit voltage and current to the –V terminals respectively applying shortest possible links. The compensation range is 10 % of U . o nom Table 6: Inhibit characteristics Outputs Connected in Series Characteristic Conditions min typ max Unit Two or more units supplying the same or different output U Inhibit U = on U …U –0.7 0.8 V inh o i min i max voltages may be connected in series. The value of the voltage U = off 2.0 7 o maximum output current to be taken is defined by that unit providing the lowest current limiting value. It should be as- I Inhibit sink curr. U = 0 6 mA inh inh sured that the outputs do not feed backwards into each other caused by their different rise/fall times at switch-on/off cycles by adding reverse polarity diodes across each out- put. 11 - 104 MELCHER Edition 2/96 - © Melcher AG The Power Partners. 11.3 Benign Environment AC-DC Converters >100 W VRW-Family Mounting Instructions VRW 150 Mounting A Mounting B Mounting C Mounting D standard Fig. 3 Mounting instruction for VRW 150 Table 7: Output derating without chassis cover for VRW 150 T Load A [°C] Mounting A Mounting B Mounting C Mounting D 30 100% 100% 100% 100% 40 100% 100% 100% 80% 50 100% 80% 80% 60% 60 50%40% 40%40% Table 8: Output derating with chassis cover for VRW 150 T Load A [°C] Mounting A Mounting B Mounting C Mounting D 30 100% 100% 100% 100% 40 100% 70% 70% 70% 50 80% 60% 60% 60% 60 40% 40% 40% 40% VRW 200, VRW 300 and VRW 450 Mounting A Mounting B Mounting A Mounting B without cover without cover with cover with cover Fig. 4 Mounting instruction for VRW 200, VRW 300, VRW 450 Table 9: Output derating without chassis cover Table 10: Output derating with chassis cover for VRW 200, VRW 300 and VRW 450 for VRW 200, VRW 300 and VRW 450 T Load T Load A A [°C] Mounting A Mounting B [°C] Mounting A Mounting B Convection 40 100% 90% Convection 30 80% 80% cooling cooling 50 80% 70% 40 80% 80% 60 60% 50% 50 60% 60% Forced air 50 100% 90% Forced air 40 100% 90% cooling cooling 60 80% 70% 50 80% 70% 70 60% 50% 60 60% 50% Edition 2/96 - © Melcher AG MELCHER 11 - 105 The Power Partners. 11.3 VRW-Family AC-DC Converters >100 W Benign Environment Immunity to Environmental Conditions Table 11: Mechanical stress Test Method Test conditions Status ±2 Damp heat Temperature: 40 °C Operating –3/+2 steady state Relative humidity: 30...90 % 2 Shock (half-sinusoidal) Acceleration amplitude: 20 g = 196.2 m/s Operating n Vibration (sinusoidal) Frequency (1 Oct/min): 10...55 Hz Operating Maximum vibration amplitude: 0.83 mm (55 Hz) 2 Acceleration amplitude: 2 g = 19.6 m/s n Test duration: 3 h (1 h each axis) Table 5: Temperature specifications Characteristic min max Unit T Operating ambient temperature range without derating –10 40 °C A T Operating ambient temperature range with derating (see fig. 1) –10 60 A T Storage temperature range –30 85 S Table 13: MTBF values MTBF Ground Benign MTBF according to MIL-HDBK-217D T = 40°C C VRW 150 types 121'830 h VRW 200 types 75'789 h VRW 300 types 60'334 h VRW 450 types 52'347 h Table 14: Isolation Test Input to output Input to case Output to case Unit Electric strenght test voltage (1 min) 3000 2000 500 V AC Isolation resistance (500 V DC) >100 >100 >100 MΩ Table 15: Safety approvals 1 Safety Approvals UL 1950 CSA 1402C TÜV VRW 150 x x x VRW 200 x x x VRW 300 x x x VRW 450 x x x 1 EN 60950 Type Key and Product Marking Type Key VRW 450 - 12 A Family ........................................................................ VRW Blank .................................................................................. Nominal output power [W].................... 150, 200, 300, 450 Dash ................................................................................ Nominal output voltage [V] ....................................... 5…48 Structure and connectors: – Open frame .......................................................... – With chassis cover ............................................. A Example: VRW 450-12A = AC-DC converter providing 12 V/40 A, 480 W output, module with chassis cover Produkt Marking Label: Type designation, applicable safety approvals and recognition marks, specific type designation, input voltage range, nominal output voltage and current and pin allocation. 11 - 106 MELCHER Edition 2/96 - © Melcher AG The Power Partners. 11.3 Benign Environment AC-DC Converters >100 W VRW-Family Mechanical Data, Input and Output Terminals European Projection Dimensions in mm. Tolerances ±1 mm unless otherwise indicated 4.5 Ş – 3 - M3 7.5 –0.5 100 80 65 16.5 19 198 LED (on) Uo adjustment 4 - M4 (Potentiometer) Output: +V Output: +V 11- M4 Sense: +S –Output: –V Output: –V Frame ground: FG Sense: –S AC input: L AC input: N 230 V AC: open A –0.5 110 V AC short B 125 40 12 24.5 Fig. 5 VRW 150, weight 890 g 48.5 152.5 3 - M4 – 9.5 U adjustment (Potentiometer) o 13.6 5.5 +V +V 2 - 5.5 Ş -V -V 5.5 +S Sense –S Sense – +R Inhibit 2 - M4 -R Return for +R L AC input 3 - M4 M4 N AC input 45 5 –0.5 152 28 233 Fig. 6 VRW 200, weight 1500 g, with cover 1610 g Edition 2/96 - © Melcher AG MELCHER 11 - 107 The Power Partners. 11 .6 33 8 121 37.5 0.5 17 90 0.5 21 50 24 4.5 0.5 25 25 62 11 8.5 2 11 1.0 50 14.7 10.5 7 .3 6.7 10 83 5 93 11.3 VRW-Family AC-DC Converters >100 W Benign Environment 175 63 3 - M4 – 9.5 Uo adjustment (Potentiometer) 13.6 5.5 +V +V 2 - 5.5 Ş -V -V 5.5 +S Sense –S Sense – +R Inhibit 2 - M4 -R Return for +R 3 - M4 L AC input M4 N AC input 45 4 – 0.5 247 5 298 Fig. 7: VRW 300, weight 2200 g, with cover 2450 g – 0.5 266.7 19 – 0.5 139 3 - M4 9.7 14.5 6.5 Uo adjustment (Potentiometer) 2 - 14.3 +V +V 2 - 8.3 Ş -V -V 6.5 –+S Sense 3 - M4 –S Sense 2 - M4 +R Inhibit M4 -R Return for +R L AC input N AC input 9 5 – 0.5 324 5 394 Fig. 8: VRW 450, weight 2800 g, with cover 3060 g 11 - 108 MELCHER Edition 2/96 - © Melcher AG The Power Partners. 11.3 121 121 10 0.5 100 0.5 14 96 14 27 24 12.7 24.5 53 42 8.3 3 11 8.3 3 11 50 1.0 50 25.4 12.3 14.5 9.3

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the VRW have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Toko America VRW 150-05 150 W 5 V DC / 30 Amp Power Supply, 85 - 132 V AC or 170 - 265 V AC (47 - 44...

Toko America VRW 150-05A 150 W 5 V DC / 30 Amp Power Supply, 85 - 132 V AC or 170 - 265 V AC (47 - 4...

Toko America VRW 150-12 150 W 12 V DC / 13 Amp Power Supply, 85 - 132 V AC or 170 - 265 V AC (47 - 4...

Toko America VRW 150-12A 150 W 12 V DC / 13 Amp Power Supply, 85 - 132 V AC or 170 - 265 V AC (47 - ...

Toko America VRW 150-15 150 W 15 V DC / 10 Amp Power Supply, 85 - 132 V AC or 170 - 265 V AC (47 - 4...

Toko America VRW 150-15A 150 W 15 V DC / 10 Amp Power Supply, 85 - 132 V AC or 170 - 265 V AC (47 - ...