TOKO AMERICA MWE30-01
Specifications
Applications
Commercial
Approvals
CE, CSA, EN, UL
Category
Power Supplies - External/Internal (Off-Board)
Efficiency
65%
Lead Free Status
Contains Lead
Line Regulation
±2%, ±0.5%
Load Regulation
±2%, ±1%, ±0.5%
Mounting Type
Chassis Mount
Number of Outputs
3
Operating Temperature
0°C ~ 60°C
Output - 1 @ Current (Max)
5 VDC @ 5A
Output - 2 @ Current (Max)
12 VDC @ 1.2A
Output - 3 @ Current (Max)
-12 VDC @ 500mA
Power (Watts)
30W
Power (Watts) - Max
30W
Power Supply Type
Switching (Open Frame)
RoHS Status
RoHS Non-Compliant
Size / Dimension
5.91" L x 2.36" W x 1.06" H (150.0mm x 60.0mm x 27.0mm)
Voltage - Input
120 ~ 240VAC
Voltage - Output
5V, ±12V
Features
- Component derating for high reliability
- Convection cooled
- Flex power topology
- High switching frequency (>100 KHz)
- MTBF >144'000 hours
- Noise standard: meets EN55011/55022
- State-of-the-art wireless transformer design
- Universal AC input
Datasheet
Extracted Text
Open Frame AC-DC Converters MWE Series TOKO 15/30 Watt AC-DC Converters MWE Series Input voltage range 85...264 V AC 3 outputs 5/±12 V DC and 5/±15 V DC 4300 V DC I/O electric strength test voltage • Universal AC input • Flex power topology • MTBF >144'000 hours • Convection cooled • High switching frequency (>100 KHz) • State-of-the-art wireless transformer design 25.4 25.4 1.0" • Component derating for high reliability 1.0" 60 110 60 150 2.36" • Noise standard: meets EN55011/55022 4.3" 2.36" 5.91" MWE 15 MWE 30 Safety according to IEC/EN 60950, UL 1950, CSA 950 LGA NRTL/C Summary The MWEseries strikes the right balance between size and Key applications performance right off the drawing board. These ultra com- Equipment for office automation, factory automation, pe- pact switchers satisfy the design engineer’s demand for ripheral, communication, security, display, test and meas- less space without sacrificing power and efficiency. Very urement, inspection and medical. low profile of one inch is maintained on most models. Choice of 15 and 30 Watt ratings. Universal AC input on all models. The modules are UL 1950 (D3), CSA 950 and LGA (IEC/EN 60950) approved. Type Survey and Key Data Table 1: Type survey 1 1 1 2 Output 1 Output 2 Output 3 Input voltage Output power Efficiency Type U I U I U I U …U T = 40°C h designation o nom o max o nom o max o mom o max i min i max A [V DC] [A] [V DC] [A] [V DC] [A] P [W] [%] o tot 5 3.0 12 0.5 –12 0.5 85…264 V AC 17.5 65 MWE 15-01 47…63 Hz 5 5.0 12 1.2 –12 0.5 31 65 MWE 30-01 110...350 V DC 5 3.0 15 0.5 –15 0.5 17.5 65 MWE 15-11 5 5.0 15 1.2 –15 0.5 31 65 MWE 30-11 1 The cumulated power of all three outputs may not exceed the total rated power. 2 Efficiency at U and I . i rated o nom Table of Contents Page Page Summary ................................................................... 9 - 41 Electromagnetic Compatibility (EMC) ....................... 9 - 45 Type Survey and Key Data ....................................... 9 - 41 Immunitiy to Environmental Conditions ..................... 9 - 46 Mechanical Data ....................................................... 9 - 47 Type Key and Product Marking ................................. 9 - 42 Functional Description............................................... 9 - 42 Safety and Installation Instructions ........................... 9 - 48 Electrical Input Data .................................................. 9 - 43 Accessories ............................................................... 9 - 49 Electrical Output Data ............................................... 9 - 43 Edition 5/5.2000 1/9 Open Frame AC-DC Converters MWE Series Type Key and Product Marking Type Key MWE 15 - 01 Series ....................................................................... MWE Nominal output power [W] ......................................... 15/30 Output configuration .................................................. 01/11 Example: MWE 15-01 = AC-DC converter providing 15 W on 3 outputs of 5 V/3A; 12 V/0.5 A and –12 V/0.5 A. Functional Description 03073 V2 Regulator G2 L Regulator Fuse Input filter Overload V3 N protection and control V1 circuit Y Output voltage FG sensing circuit G1 FG Y YY Fig. 1 Block diagram MWE 15 03074 V2 Regulator G2 L Fuse Input filter Regulator V3 N V1 Y FG G1 FG Y Y Overload protection Output voltage and control sensing circuit circuit Fig. 2 Block diagram MWE 30 Edition 5/5.2000 2/9 Open Frame AC-DC Converters MWE Series Electrical Input Data General Condition: T = 25°C unless otherwise specified A Table 2: Input data Characteristics MWE 15-... MWE 30-... Unit U Rated input voltage 100, 120, 200, 220, 240 V AC i rated U Input voltage range 85…264 i f Line frequency 47…63 Hz i 1 I Input current (typ.) 100/200 V AC 0.45/0.25 0.85/0.45 A i 1 l Inrush current (max.) 100 V AC 30 i m I Leakage current (max.) 100 V AC 0.5 mA i leak 1 At U and I . i rated o nom Electrical Output Data General Condition: T = 25°C unless otherwise specified A Table 3a: Output data 15 W types Type MWE 15-01 MWE 15-11 Characteristics V1 V2 V3 V1 V2 V3 Unit U Output voltage nom. 5 12 –12 5 15 –15 V o DU Voltage setting tolerance ±1 ±4 ±4 ±1 ±4 ±4% o I Voltage setting load 1.25 0.15 0.1 1.25 0.15 0.1 A o set U Overvoltage protection Not provided Not provided o P I Output current min. 0.5 0 0 0.5 0 0 A o typ. 2 0.3 0.2 2 0.3 0.2 max. 3 0.5 0.5 3 0.5 0.5 2 I Output current limitation 105 105 % o L P Total rated output max. 17.5 17.5 W o tot P Output power 15 6 6 15 7.5 7.5 o max 1 u Ripple-noise max. 100 150 150 100 150 150 mVpp o DU Line regulation 85...264 V ±2.0 ±0.5 ±0.5 ±2.0 ±0.5 ±0.5 % o U DU Load regulation 0...100% ±2.0 ±1.0 ±0.5 ±2.0 ±1.0 ±0.5 o I DU Drift (t = 0.5...8 h) typ. 0.3 0.3 o t a Change in temp., 0…50°C ±1 ±1 Uo 1 t Rise time max. 100 100 ms o r 1 t Hold up time 100/200 V AC 10/20 10/20 o h min 1 h Efficiency typ. 65 65 % 1 At U and I and normal temperature. i rated o nom 2 Operating at approx. 105% of rated power, constant current method, automatic recovery. Edition 5/5.2000 3/9 Open Frame AC-DC Converters MWE Series Table 3b: Output data 30 W types Type MWE 30-01 MWE 30-11 Characteristics V1 V2 V3 V1 V2 V3 Unit U Output voltage nom. 5 12 –12 5 15 –15 V o DU Voltage setting tolerance ±1 ±4 ±4 ±1 ±4 ±4% o I Voltage setting load 1.85 0.5 0.5 1.85 0.5 0.5 A o set U Overvoltage protection Not provided Not provided o P I Output current min. 10010 0 A o typ. 3 1 0.33 3 0.8 0.21 max. 5 1.2 0.5 5 1.2 0.5 2 I Output current limitation 105 105 % o L P Total rated output max. 31 31 W o tot P Output power 25 14 6 25 18 7.5 o max 1 u Ripple-noise max. 100 150 150 100 150 150 mVpp o DU Line regulation 85...264 V ±2.0 ±0.5 ±0.5 ±2.0 ±0.5 ±0.5 % o U DU Load regulation 0...100% ±2.0 ±1.0 ±0.5 ±2.0 ±1.0 ±0.5 o I DU Drift (t = 0.5...8 h) typ. 0.3 0.3 o t a Change in temp., 0…50°C ±1 ±1 Uo 1 t Rise time max. 100 100 ms o r 1 t Hold up time 100/200 V AC 10/20 10/20 o h min 1 h Efficiency typ. 65 65 % 1 At U and I and normal temperature. i rated o nom 2 Operating at approx. 105% of rated power, constant current method, automatic recovery. Input and Output Terminals Table 4: Input and output terminals Terminal Function Explanation L Line input 1. Connect to a sine wave of 47...63 Hz, 85...264 V AC, single phase. N Neutral input 2. Use a double or triple core cable fo the input line. 3. Space the AC input line as far as possible from the DC output line. FG Frame ground terminal Connect with low impedance to ground line of equipment on which the power supply is mounted. V1 Output Terminal 1 Stabilized output of 5 V DC. V2 Output Terminal 2 Stabilized output of 12 or 15 V DC. V3 Output Terminal 3 Stabilized output of –12, or –15 V DC. G1, G2 Ground Terminals G1: ground terminal for V1, G2: ground terminal for V2 and V3. G1 and G2 are internally interconnected. Proper Method of Operation Inrush Current To achieve the proper output voltage from each of the three All models feature inrush current limitation circuit by means output channels, the load currents must be within the mini- of power thermistors. Switching the AC input on/off repeat- mum-maximum ratings. If the load current is below the edly in rapid succession (less than 2 minutes waiting) minimum, use a pre-load. should be avoided. An appropriate AC switch for each model based on its specifications should be provided. Output Current Limitation Series or Parallel Connection Each channel has its own built-in current limitation at approx. 105% of the rated currents. In the case of overload- The outputs cannot be operated in series or parallel con- ing, the circuit operates to avoid excessive current. After nection with other type of sources. removal of the overload, the circuit automatically resets. Edition 5/5.2000 4/9 Open Frame AC-DC Converters MWE Series P /P Thermal Considerations o o max 05118 The relation between the maximum allowed output power 1.2 P , the temperature T of the surrounding air and the o allwed A 1.0 mounting method is given in the: Installation Instruction. The percentage rates apply if the AC-DC converter is lo- 0.8 cated in free, quasi-stationary air (convection cooling). The following figure shows the allowed output power of an 0.6 AC-DC converter. 0.4 For P values see: Type Survey and Key Data. The ther- o max mal conditions are influenced by input voltage, output cur- 0.2 rent, airflow and temperature of surrounding components 0 T [°C] and surface. A –10 0 10 20 30 40 50 60 70 Caution: The installer must ensure that under all operat- Fig. 3 ing conditions T remains within the limits stated in the ta- A Maximum allowed output power versus ambient tempera- ble. ture Electromagnetic Compatibility (EMC) Electromagnetic Immunity A metal oxide VDR together with an input fuse and an input but especially in battery driven mobile applications. The filter form an effective protection against high input tran- MWE series has been successfully tested to the following sient voltages which typically occur in most installations, specifications: Table 5: Immunity type tests Phenomenon Standard Level Coupling Value Waveform Source Test In Per- 3 mode applied Imped. procedure oper. form. 1 Electrostatic IEC/EN x air discharge 6000 V 1/50 ns 330 Ω 10 positive and yes p discharge 61000-4-2 to frame 10 negative discharges 1 Electromagnetic IEC/EN x antenna in 10 V/m sine wave mod- 26…1000 MHz yes field 61000-4-3 1 m distance ulated w. 1 kHz 1 Electrical fast IEC/EN x i/c, +i/–i 2000 V 5/50 ns 50 Ω 1 min positive yes p transient/burst 61000-4-4 1 min negative bursts per coupling mode 21 Surge IEC/EN x i/c 2000 V 1.2/50 µs 12 Ω 5 pos. and 5 neg. yes p 61000-4-5 surges per coupling mode 1 Normal operation, no deviation from specifications. 2 No load. 3 i = input, o = output, c = case. Edition 5/5.2000 5/9 Open Frame AC-DC Converters MWE Series Electromagnetic Emissions [dBµV] [dBµV] 07086 07087 90 90 80 80 A A 70 70 B B 60 60 50 50 40 40 30 30 20 20 10 10 0 MHz 0 MHz Fig. 4 Fig. 5 The disturbance voltage (quasi peak) at the input accord- The disturbance voltage (quasi peak) at the input accord- ing to CISPR11/22 and EN 55011/22, measured at U ing to CISPR11/22 and EN 55011/22, measured at U i rated i rated and I for MWE 15-01 and I for MWE 30-11 o nom o nom Immunitiy to Environmental Conditions Table 6: Mechanical stress Test Parameters Ca Humidity Relative humidity: 30...85% (no condensation) Unit operating/storage 2 Ea Shock Acceleration: 20 g (196.2 m/s ) n Bump duration: 11 ±5 ms Number of bumps: 18 (3 each direction) Unit not operating Fc Vibration Frequency: 5...55 Hz Maximum vibration amplitude: 10 mm (5...10 Hz) 2 Acceleration: 2 g (19.6 m/s , 10...55 Hz) n Duration: 3 h (1 h each axis) Unit not operating Table 7: Temperature specifications Characteristic Conditions min max Unit T Ambient temperature range without derating U ...U –10 40 °C A i min i max T Ambient temperature range with derating –10 60 A (see: Thermal Considerations) T Storage temperature range Not operational –20 75 S Table 8: MTBF values MTBF Type Ground Benign T =25°C C According to MIL-HDBK-217D MWE 15 144'000 h MWE 30 126'000 h Edition 5/5.2000 6/9 0.01 0.02 0.05 0.1 0.5 1 2 5 10 20 30 0.01 0.02 0.05 0.1 0.5 1 2 5 10 20 30 Open Frame AC-DC Converters MWE Series Mechanical Data Dimensions in mm. Tolerances ±1 mm unless otherwise indicated. European Projection M3 (depth 6 mm max) M3 ±0.5 4 46 1 FG M3 3 N AC input Input connector 5 L B3P5-VH (JST) G1 5 V1 Output connector V3 B5P-VH (JST) G2 1 V2 M3 ±0.5 99 4 110 max Fig. 6 MWE 15, weight: 150 g M3 (depth 6 mm max) M3 ±0.5 35 100 ±0.5 7 138 1 FG M3 Input connector 3 N AC input B3P5-VH (JST) 7 G1 5 L V1 Output connector V3 B7P-VH (JST) M3 G2 1 V2 150 max Fig. 7 MWE 30, weight: 230 g Edition 5/5.2000 7/9 ±0.6 60 25.4 60 ±0.6 25.4 ±0.5 ±0.5 12 33 23 8 ±0.5 ±0.5 5.5 50.5 11 8 09086 09087 Open Frame AC-DC Converters MWE Series Safety and Installation Instructions Installation Instructions Our AC-DC converters are components, intended exclu- in the wiring to the phase terminal L. A second fuse in the sively for inclusion within other equipment by an industrial wiring to the neutral terminal N is needed if: assembly operation or by professional installers. Installa- • Local requirements demand an individual fuse in each source line tion must strictly follow the national safety regulations in compliance with the enclosure, mounting, creepage, clear- • Neutral and earth impedance is high or undefined ance, casualty, markings and segregation requirements of • Phase and neutral of the mains are not defined or cannot the end-use application. See also: Technical Information: be assigned to the corresponding terminals (L to phase Installation and Application. and N to neutral) Connection to the system shall be made via the terminal Important: Do not open the modules, or guarantee will block at the rear side of the unit according to: Terminal As- be invalidated. signment. Make sure that there is sufficient air flow possible for con- For safety reasons it is essential to connect the FG and vection cooling. This should be verified by measuring the ACG terminals with protective earth. See also: Safety of op- ambient temperature when the unit is installed and oper- erator accessible output circuit. ated in the end-use application. The maximum specified A fuse is built-in in the connection from the L terminal of the ambient temperature T must not not be overriden, de- A max unit. Since this fuse is designed to protect the unit in case of pending on output power and mounting method. See: Ther- an overcurrent and does not necessarily cover all customer mal Considerations and table Allowed output power by needs, an external fuse suitable for the application and in mounting method. compliance with the local requirements should be installed 09064 Air Mounting Methods 09063 Ample spacing Air Upper panel with good ventilation Ample spacing Air This surface in contact with chassis side or with convection cooling Case mounted on Case side in Main chassis material with good contact with Case mounted on material heat conduction chassis with good heat conduction Fig. 8 Fig. 9 Hoirizontal mounting Vertical mounting Standards and approvals Isolation The AC-DC converters correspond to class I equipment The electric strength test is performed as factory test in ac- and are UL recognized according to UL 1950, UL recog- cordance with IEC/EN 60950 and UL 1950 and should not nized for Canada to CAN/CSA 950 and LGA approved to be repeated in the field. Power-One will not honour any IEC/EN 60950 standards. guarantee claims resulting from electric strength field tests. The units have been evaluated for: Table 9: Isolation • Building in, Characteristic Input to Input to Output to Unit • Basic insulation between input and frame and double or frame output frame reinforced insulation between input and output, based on 1 their maximum input voltage. Electric strength - 3.0 -kV rms test voltage 1 s • Operational insulation between output and frame, 1 - 4.3 -kV DC • The use in a pollution degree 2 environment, Insulation resist. - >100 >100 MΩ • Connecting the input to an overvoltage category II circuit at 500 V DC if >150 V or an overvoltage category III circuit if ≤150 V. Leakage current - – <15 mA The AC-DC converters are subject to manufacturing sur- 1 veillance in accordance with the above mentioned UL, In accordance with IEC/EN 60950 only subassemblies are tested in factory with this voltage. CSA, EN and with ISO 9001 standards. Edition 5/5.2000 8/9 Open Frame AC-DC Converters MWE Series Safety of operator accessible output circuit If the output circuit of an AC-DC converter is operator ac- EN 60950 up to a configured output voltage (sum of nomi- cessible, it shall be an SELV circuit according to the IEC/EN nal voltages if in series or +– configuration) of 44 V. 60950 related safety standards However, it is the sole responsibility of the installer to as- The following table shows a possible installation configura- sure the compliance with the relevant and applicable safety tion, compliance with which causes the output circuit of the regulations. More information is given in: Technical Infor- AC-DC converter to be an SELV circuit according to IEC/ mation: Safety. Table 10: Safety concept leading to an SELV output circuit Conditions AC-DC converter Installation Result Supply voltage Grade of isolation, provided by the Measures to achieve the resulting Safety status of the AC-DC converter AC-DC converter safety status of the output circuit output circuit Mains ≤250 V AC Double or reinforced Earthed frame SELV circuit 10021 Table 11: Safety approvals Fuse + ~ Safety Approvals NRTL/C CSA LGA Mains AC-DC SELV Fuse con- – ~ MWE 15, MWE 30 UL 1950 CSA 950 IEC/EN 60950 verter Earth connection Protection Degree Fig. 10 The protection degree of the AC-DC converters is IP 20, Schematic safety concept exept in the vicinity ot the terminal block, where it depends Use fuses and earth connection as per: Installation In- on the installation. structions and table: Safety concept leading to an SELV output circuit. Accessories Connector Kits Table 12: Connector kit specification Type Connector Input Qty. Contacts Qty. Output Qty. Contacts Qty. kit designation housing housing MWE 15 MLCK01 VHR-5N 1 SVH-21T-P1.1 3 VHR-5N 1 SVH-21T-P1.1 5 MWE 30 MLCK02 VHR-5N 1 SVH-21T-P1.1 3 VHR-7N 1 SVH-21T-P1.1 7 Cable Kit Table 13: Cable kit (to be ordered separately from power supply) Position Type of Power Material Length Wire color at cable kit supply Cross section V1 V2 V3 G AC (L) AC (N) FG AC input CB11 MWE 15 UL 1015 60 cm –– – – Black White Green- 2 side MWE 30 AWG 20 ≈ 0.50 mm (5) (3) Yellow (1) DC output CB12 MWE 15 UL 1007 60 cm Red Brown Blue Black –– – 2 side AWG 18 ≈ 1 mm (4) (1) (3) (2, 5) CB13 MWE 30 UL 1007 60 cm Red Brown Blue Black –– – 2 AWG 18 ≈ 1 mm (4, 5) (1) (3) (2, 6, 7) Edition 5/5.2000 9/9
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the MWE30-01 have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers







What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods