TELKOOR POWER SUPPLIES CPCI-AC-3U-300W
Datasheet
Extracted Text
CPCI-3U-AC-300W-R Electrical Specification for: 300W AC Input 3U CompactPCI Power Supply Telkoor Part 900-4602-10 Number: CUSTOMER SIZE CAGE CODE S5417 DWG. NO. 4602-DOC1-10 REV A1 ELMA SCALE RELEASE DATE 12/9/06 SHEET OF 1 6 REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective A 12/9/06 Product Release 12/9/06 A1 17/3/08 Operation Temp -20 Deg C Update 17/3/08 Approvals Name Date Written by: S. Sadot 10/9/06 Engineering: S. Sadot 10/9/06 Sales & Marketing: M. Allon 10/9/06 Management: Y. Ben-Ami 12/9/06 CUSTOMER SIZE CAGE CODE S5417 DWG. NO. 4602-DOC1-10 REV A1 ELMA SCALE RELEASE DATE 12/9/06 SHEET OF 2 6 INPUT SPECIFICATIONS Parameter Conditions/Description Min Nom Max Units Input Voltage - AC Continuous input range 90 250 VAC Input Frequency 45 440 Hz Input Protection Non-user serviceable, internally-located input fuse Inrush Surge Current Internally limited by thermistor 60 A @ 220V Operating Frequency Switching frequency of main output 70 90 KHz transformer Output Specifications Output Adjustment Output Line Load Ripple & noise Output Voltage Range Current Regulation Regulation %pK-pK (Note 1) V1 +5V 4.8 ÷5.2 30A 0.5% ± 1% 60mV V2 +3.3V 3.1 ÷ 3.5 40A 0.5% ± 1% 60mV V3 +12V N/A 5.0A 0.5% ± 4% 120mV V4 -12V N/A 1.0A 0.5% ± 4% 120mV Notes: 1) maximum peak-to-peak expressed in mV @ 20MHz bandwidth. 2) Maximum power on V1 + V3 not to exceed 185W 3) Maximum power on V2 + V4 not to exceed 140W Parameter Conditions/Description Min Nom Max Units Efficiency Full rated load @ 110 VRMS 79 % Minimum Load V1, V2, V3, V4 Minimum load required to maintain regulation None Ripple and Noise Full load, 20 MHz bandwidth See above table Output Power 40CFM 300 W Overshoot/Undershoot Output voltages overshoot/undershoot at turn-on. 0 % Regulation Varies by output. Total regulation includes: line changes over the specified input range, changes See above table in load starting at 50% load and changing to 100% Turn-on Delay Time required for initial output voltage < 2 Sec stabilization Hold up time Hold up @ full load at 220VAC input 16 mSec Output voltage rise time after Turn-on Rise time of output voltage from 10% to 90% of 20 mSec delay its final value after initial turn-on delay Initial Setting Accuracy for V1 & V2 ± 1 % Fully compliant with the PICMG 2.11 CompactPCI specifications CompactPCI and PCIMG are registered trademarks on the PCI industrial Computer Manufacturers Group. CUSTOMER SIZE CAGE CODE S5417 DWG. NO. 4602-DOC1-10 REV A1 ELMA SCALE RELEASE DATE 12/9/06 SHEET OF 3 6 INTERFACE SIGNALS AND INTERNAL PROTECTION Parameter Conditions/Description Min Nom Max Units Over-voltage Protection % Latch style over-voltage protection (V1, V2 & V3) 110 130 Vnom Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition Over temperature Protection System shutdown due to excessive internal temperature measured on the internal base plate, 90 ° C automatic restart. Power Fail (FAIL#) TTL compatible signal. Open collector. Active low signal. Indicates outputs below 90% for V1 and/or V2 and/or V3 Current Share Accuracy of shared current with up to 6 parallel units. Single wire current 10 % share on V1 & V2. Remote Sense Available on V1 & V2. Total voltage compensation for cable losses with 200 mV respect to the main output Inhibit (INH#) TTL-compatible signal. Inhibited with GND or TTL “0” Contact closure to external ground to start unit. On shortest pin (last make, first break) Enable (EN#) during normal operation pulled up to +5V internally. Over temperature Warning Provides a warning window when power supply temperature exceeds rating and before over (DEG#) temperature protection shuts the unit off. TTL-compatible open Front Panel LED Status Indicator A single bi-color LED - Input OK (Green), Output Failure (Red) (*) Tested with an external TBD line filter SAFETY, REGULATION AND EMI SPECIFICATION Parameter Conditions/Description Min Nom Max Units Agency Approvals UL 60950-1, EN60950-1 & CE markings Approved Dielectric Withstand Voltage Input to Output per EN60950-1 4200 VDC Electromagnetic Interference EN55022/CISPR22 – Conducted & Radiated B (*) Class Harmonic Current emission, Per EN6100-3-2/3 In Compliance voltage fluctuations ESD Susceptibility Per EN61000-4-2, level 4 8 kV Radiated Susceptibility Per EN61000-4-3, level 3 10 V/M EFT/Burst Per EN61000-4-4, level 3 ±2 kV Input Surge Per EN61000-4-5, level 3. Line to Line 1 KV Line to Ground 2 Conducted Disturbance Per EN61000-4-6, level 2 3 V Insulation Resistance Input to Output 10 MΩ CUSTOMER SIZE CAGE CODE S5417 DWG. NO. 4602-DOC1-10 REV A1 ELMA SCALE RELEASE DATE 12/9/06 SHEET OF 4 6 ENVIRONMENTAL SPECIFICATIONS Parameter Conditions/Description Min Nom Max Units Altitude Operating 10K Feet Non-Operating 50K Feet Operating Temperature With 40CFM forced-air cooling At 100% load -20 55 °C De-rated linearly above 55°C by 2.5% per°C Storage Temperature -40 85 °C Relative Humidity Non-Condensing 5 95 %RH Shock Peak acceleration 20 GPK Vibration Random vibration, 10Hz to 500 Hz, 3 axis 2 GRMS OVERALL SIZE: 5.07”H x 1.60”W x 6.40”D (128.7mm x 40.6mm x 162.5mm) WEIGHT: 800 gr. Outline Drawing: CUSTOMER SIZE CAGE CODE S5417 DWG. NO. 4602-DOC1-10 REV A1 ELMA SCALE RELEASE DATE 12/9/06 SHEET OF 5 6 CPCI-3U-AC-300Watt Connector PinOut Pin-Length Signal Pin # Description Type Name 1-4 Normal V1 V1 Output 5-12 Normal RTN V1 and V2 Return 13-18 Normal V2 V2 Output 19 Normal RTN V3 Return 20 Normal V3 V3 Output 21 Normal V4 V4 Output 22 Normal RTN Signal Return 23 Normal Reverse Reverse 24 Normal RTN V4 Return 25 Normal GA-0 Geographic ADD-0 26 Normal Reverse Reverse 27 Short EN# Enable 28 Normal GA-1 Geographic ADD-1 29 Normal NC Not Connected 30 Normal V1 Sense V1 Remote Sense 31 Normal GA-2 Geographic ADD-2 32 Normal NC Not Connected 33 Normal V2 Sense V2 Remote Sense 34 Normal S RTN Sense Return 35 Normal V1 Share V1 Current Share 36 Normal NC Not Connected 37 Normal IPMB_SCL System Manager Bus 38 Normal DEG# Degrade Signal 39 Normal INH# Open – ON Low - OFF 40 Normal IPMB_SDA System Manager Bus 41 Normal V2 Share V2 Current Share 42 Normal FAL# Fail Signal 43 Normal IPMB_PWR System Manager - Power 44 Normal NC Not Connected 45 Long Chassis GND Chassis Ground 46 Long AC Neutral AC Input Neutral 47 Long AC Line AC Input Line CUSTOMER SIZE CAGE CODE S5417 DWG. NO. 4602-DOC1-10 REV A1 ELMA SCALE RELEASE DATE 12/9/06 SHEET OF 6 6
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the CPCI-AC-3U-300W have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods