Elite.Parts Manufacturers T TELEMECANIQUE XCK-Y03
About product Datasheet FAQ

TELEMECANIQUE XCK-Y03

Image of TELEMECANIQUE XCK-Y03

Description

XCK-Y03-TELEMECANIQUE-KEY

Part Number

XCK-Y03

Price

Request Quote

Manufacturer

TELEMECANIQUE

Lead Time

Request Quote

Category

TBD

Datasheet

pdf file

45SAFETY_Interlock_Switche-2066133379s.pdf

799 KiB

Extracted Text

XCS Safety Interlock Specifications General Characteristics (Metal, Turret Head, Types XCS-A, XCS-B, XCS-C, and XCS-E Plastic, Double Insulated, Turret Head, Types XCS-PA, XCS-TA, XCS-PL, XCS-PR, XCS-TL, XCS-TR, and XCS-TE) Complies with international and domestic safety standards. OSHA 1910, IEC 60204-1, EN 60204-1, VDE 0660, ANSI B11.19, INRS (France), EN1088, EN292 Environment Safety Interlock Type XCS-A, XCS-B, XCS-C, XCS-E (metal) XCS-PA, XCS-TA, XCS-PL, XCS-PR, XCS-TL, XCS-TR, XCS-TE (plastic) Products IEC 947-5-1, EN 60947-5-1, UL 508, CSA C22-2 N° 14 Conforming Machine to standards IEC 60204-1, EN 60204-1, EN 1088 assemblies Product certifications UL, CSA, BG, TUV Operation: -13°F to 158°F (-25°C to 70°C), XCS-E: -13°F to 104°F (-25°C to 40°C), Ambient air temperature q q q q XCS-TE: -13°F to 140°F (-25°C to 60°C) Storage -40°F to 158°F (-40°C to 70°C) Vibration resistance 5 gn (10...500 Hz) conforming to IEC 68-2-6 Shock resistance 10 gn (duration 11 ms) conforming to IEC 68-2-27 Electric shock protection Class 1 conforming to IEC 536 Degree of protection IP 67 conforming to IEC 529 c and IEC 947-5-1; Metal: Type 4, 4X, 12; Plastic: Type 4 and 4X Indoor, 12 1 entry with 1/2” NPT on XCS-PA, XCS-PL, XCS-PR 1 entry with 1/2 NPT on XCS-A, XCS-B, XCS-C Conduit entry 1 entry for 1/2" conduit adapter on XCS-TE 2 entries with 1/2 NPT on XCS-E 2 entries for 1/2” conduit adapter on XCS-TA, XCS-TL, XCS-TR c The enclosure rating for these switches is for the protection of the live electrical components. During installation and operation, precautions must be taken to prevent any ingress of contaminants, particles, and corrosives, including liquids containing solids, from entering into the actuating key area. If precautions are not taken, switches may not perform to published specifications. Use in a salt atmosphere is not recommended. q Minimum temperature: The minimum temperatures listed are based on the absence of freezing moisture or w ater. Care should be taken to avoid sub-freezing temperatures where dripping or splashing water is present and to avoid bringing a cold device into a humid atmosphere and then back into sub-freezing temperatures. The water or moisture may freeze around internal or external components and prevent it from performing as intended. Electrical Characteristics XCS-A, XCS-B, XCS-C, XCS-PA,XCS-TA, XCS-PL, XCS-PR, XCS-TL, XCS-TR: ~ AC-15, A300: Ue = 240 V, Ie = 3 A or Ue = 120 V, Ie = 6 A XCS-E, XCS-TE: ~ AC-15, B300: Ue = 240 V, Ie = 1.5 A or Ue = 120 V, Ie = 3 A Electrical contact rating All models: = DC-13, Q300: Ue = 250 V, Ie = 0.27 A or Ue = 125 V, Ie = 0.55 A conforming to IEC 947-5-1, EN 60947-5-1 XCS-A, XCS-B, XCS-C, XCS-PA, XCS-PL, XCS-PR, XCS-T A, XCS-TL, XCS-TR: Ithe = 10A. Rated thermal current in enclosure XCS-E, XCS-TE: Ithe: 6 A Ui = 500 V conforming to IEC 947-5-1 Rated insulation voltage Ui = 300 V conforming to UL 508, CSA C22-2 N° 14 XCS-A, XCS-B, XCS-C, XCS-PA, XCS-TA, XCS-PL, XCS-PR, XCS-TL, XCS-TR: U imp = 6 kV conforming to IEC 947-5-1 Rated impulse withstand voltage XCS-E, XCS-TE: U imp = 4 kV conforming to IEC 947-5-1 Direct opening N.C. contacts meets the IEC and EN requirements for positive opening contacts per Direct opening contacts IEC 947-5-1, EN 60947-5-1; and NEMA ICS-5, part 6 (direct opening action). Resistance across terminals £30 mW conforming to IEC 957-5-4 Short-circuit protection 10 A Class CC fuse. Outside U.S. use cartridge fuse type gG (gl) 2 2 Wiring Screw clamp terminals. Terminal capacity, min.: 1 #20 A WG (1 x 1.05 mm ), max.: 2 #16 AWG (2 x 1.5 mm ) AC Voltage and Current Ratings 50-60 Hz Maximum Current, Amperes Thermal Continuous Voltamperes Contact Rating Designation 120 Volts 240 Volts 480 Volts 600 Volts Test Current, Amperes Make Break Make Break Make Break Make Break Make Break A300 10 60 6.00 30 3.00 . . . . . . . . . . . . 7200 720 B300 5 30 3.00 15 1.50 . . . . . . . . . . . . 3600 360 DC Voltage and Current Ratings Thermal Continuous Test Maximum Make or Break Current, Amperes Make or Break at 300 Volts or Contact Rating Designation Current, Amperes Less, Voltamperes 125 Volts 250 Volts 301 to 600 Volts Q300 2.5 0.55 0.27 . . . 69 Complementary characteristics Actuation speed Maximum: 19.7 in/s (0.5 m/s), Minimum: 0.39 in/s (0.01 m/s) Resistance to forcible key withdrawal XCS-B and XCS-C: >337 lbs. (1500 N); XCS-E: 450 lbs. (2000 N); XCS-TE: 112 lbs. (500 N) Maximum operating rate For maximum life: 600 operating cycles per hour XCS-A, XCS-B, XCS-C, XCS-E: 4.5 lbs. (20 N); XCS-PA, XCS-TA, XCS-TE: 3.4 lbs. (15 N); Minimum force for positive opening XCS-PL, XCS-PR: 35.4 oz. in. (.25 Nm); XCS-TL, XCS-TR: 63.73 oz. in. (.45 Nm) Electromagnet characteristics Load factor 100% Voltage limits -20%, +10% of the rated operational voltage (including ripple on) conforming to IEC 947-1 Consumption Inrush: 10 VA. Sealed: 10 VA LED indicator characteristics Rated insulation voltage 50 V conforming to IEC 947-1 (24 - 48 V LEDs) 250 V conforming to IEC 947-1 (110 - 240 V LEDs) Current consumption 7 mA 7 mA Rated operational voltage 24/48 VAC or VDC 110/240 VAC Voltage limits 20...52 VAC or VDC (including ripple) 95...264 VAC (including ripple) Protection against overvoltages Yes Yes © 2000 Square D 23-6 All Rights Reserved 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com MACHINE SAFEGUARDING 23 PRODUCTS Components for Machine Safety Applications XCS Safety Interlock Metal, turret head c, types XCS-A, XCS-B, and XCS-C Conduit entry tapped 1/2” NPT References and Characteristics Type of switch Without locking of actuating key With locking - pushbutton unlocking With locking, manual unlocking p 1 orange LED 1 orange LED 1 orange LED 1 orange LED 1 orange LED 1 orange LED LED indication on opening of N/C contacts Without LED 24/48 VAC or Without LED 24/48 VAC or Without LED 24/48 VAC or 110/240 VAC 110/240 VAC 110/240 VAC VDC VDC VDC References of switches without actuating key (Direct opening N.C. contacts meets the IEC and EN requirements for positive opening contacts per IEC 947-5-1 section 3, EN 60 947-5-1.) N/C + N/O + N/O slow break j a XCS-A503 XCS-A513 XCS-A523 XCS-B503 XCS-B513 XCS-B523 XCS-C503 XCS-C513 XCS-C523 N/C + N/C +N/O slow break j a XCS-A703 XCS-A713 XCS-A723 XCS-B703 XCS-B713 XCS-B723 XCS-C703 XCS-C713 XCS-C723 N/C + N/C +N/C slow break j XCS-A803 - - XCS-B803 - - XCS-C803 - - Weight oz. (kg) 15.5 (0.440) 15.5 (0.440) 15.5 (0.440) 17 (0.480) 17 (0.480) 17 (0.480) 17 (0.480) 17 (0.480) 17 (0.480) Price $92.00 $135.00 $135.00 $122.00 $165.00 $165.00 $142.00 $185.00 $185.00 c 90° increments throughout 360° p Unlocking by Tubular High Security key operated lock j Schematic diagrams shown represent the contact state while the actuating key is inserted in the head of the switch. a The N/O contacts will close after the N/C contacts open. They do not change state simultaneously. References of actuating keys Description Straight key Wide key Pivoting key Sliding bolt actuating key For switches XCS-A, B, C, E XCS-Z01 XCS-Z02 XCS-Z03 XCS-Z05 Weight oz. (kg) 1.0 (0.021) 1.0 (0.021) 3.3 (0.095) 21.2 (0.600) Price $10.00 $10.00 $20.00 $95.00 The devices above are available with metric conduit. • To order devices tapped for 13mm cable gland, conforming to NF C68-300 (DIN Pg 13.5): Change the last character in the part number to 1 For example: XCSC723 is changed to XCSC721 • To order devices tapped for M20 x 1.5 for ISO cable gland: Change the last character in the part number to 2 For example: XCSC723 is changed to XCSC722 The N.C. contacts only should be used in the safety control circuit. The N.O. contacts are provided solely for signalling – NOT for safety functions. Neither replacement parts nor components are available. These devices are not to be repaired or adjusted. The complete switch should be replaced. When designing a door or gate guarding system, these guidelines must be followed: • The actuating key alone must not be used as the sole means to hold the gate or guard closed. A separate locking or latching mechanism must be used to hold door closed. • The safety interlock switch must not be used as a mechanical stop for the moving guard. A separate mechanical stop must be provided. • The actuating key must not be used as a gate guiding device. Install a guide for the guard to ensure proper alignment. File LR 44087-94 File E164353 Class 3211-03 CCN: NKCR TM For additional information, reference Catalog # 9007CT9702R2/00 or D-FAX # 1619. Discount © 2000 Square D T 3/00 Schedule 23-7 All Rights Reserved Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 12 11 22 21 22 21 22 21 14 13 32 31 32 31 14 13 34 33 MACHINE SAFEGUARDING 23 PRODUCTS XCS Safety Interlock References and Characteristics Metal, turret head c, type XCS-E Conduit entry tapped 1/2 NPT References and Characteristics Type of switch With interlocking, locking by electromagnet Locking Without Power.k Actuating key locks into switch when inserted. This is typically preferred as the door is secured regardless of electrical Type of interlocking power availability or failure. Applying power to the electromagnet will unlo ck actuating key and allow it to be removed from the switch. Orange LED: “guard open” signaling LED indication Green LED: “guard closed and locked” signaling Supply voltage of electromagnet 24 VAC or VDC 48 VAC or VDC 110/120 VAC or VDC j 220/240 VAC or VDC j References of switches without actuating key (select actuating key from page 23-7) (Direct opening N.C. contacts meets the IEC and EN requirements for positive opening contacts per IEC 947-5-1 section 3, EN 60 947-5-1.) N/C + N/O + N/O (2 N/O staggered) XCS-E5313 XCS-E5323 XCS-E5333 XCS-E5343 slow break u a N/C + N/C + N/O (N/O staggered) XCS-E7313 XCS-E7323 XCS-E7333 XCS-E7343 slow break u a N/C + N/C + N/C slow break u q XCS-E8313 XCS-E8323 XCS-E8333 XCS-E8343 Weight oz. (kg) 40 (1.140) 40 (1.140) 40 (1.140) 40 (1.140) Price $261.00 $261.00 $291.00 $291.00 Type of switch With interlocking, locking by electromagnet Locking With Power.k Actuating key locks into switch only when actuating key is inserted and power is applied to the electromagnet. Door or guard is not locked in the event of a power failure or when power is removed from the electromagnet. Removing power from the electromagnet will unlock actuating key and allow it to be removed from the switch. Type of interlocking Note: Locking with power devices do not meet European standards regarding the safety of machinery, especially EN 1088 regarding guard locking. European standards do not allow a “locking with power” function for gate or door guarding/locking. Locking without power devices meet European requirements, and should be used when machinery is to be shipped to Europe or where machinery must meet European standards. Orange LED: “guard open” signaling LED indication Green LED: “guard closed and locked” signaling Supply voltage of electromagnet 24 VAC or VDC 48 VAC or VDC 110/120 VAC or VDC j 220/240 VAC or VDC j References of switches without actuating key (select actuating key from page 23-7) (Direct opening N.C. contacts meets the IEC and EN requirements for positive opening contacts per IEC 947-5-1 section 3, EN 60 947-5-1.) N/C + N/O + N/O (2 N/O staggered) XCS-E5513 XCS-E5523 XCS-E5533 XCS-E5543 slow break u a N/C + N/C + N/O (N/O staggered) XCS-E7513 XCS-E7523 XCS-E7533 XCS-E7543 slow break u a N/C + N/C + N/C slow break u q XCS-E8513 XCS-E8523 XCS-E8533 XCS-E8543 Weight oz. (kg) 40 (1.140) 40 (1.140) 40 (1.140) 40 (1.140) Price $334.00 $334.00 $364.00 $364.00 The N.C. contacts only should be used in the safety control c 90° increments throughout 360° circuit. The N.O. contacts are provided solely for signalling – k A key operated lock enables the forced opening of the interlocking device, allowing opening of the N/C safety contacts NOT for safety functions. and subsequent actuating key withdrawal. j For use on 110/120 VDC or 220/240 VDC, remove the LED indicator module. Neither replacement parts nor components are available. u Schematic diagrams shown represent the contact states while the operating key is inserted in the head of the switch. These devices are not to be repaired or adjusted. The a The N/O contacts will close after the N/C contacts open. They do not change state simultaneously. complete switch should be replaced. qDevices with 3 N/C contacts are supplied with a single green LED. The devices above are available with metric conduit. When designing a door or gate guarding system, these • To order devices tapped for 13mm cable gland, conforming to NF C68-300 (DIN Pg 13.5): guidelines must be followed: Change the last character in the part number to 1 • The actuating key alone must not be used as the sole For example: XCSE7333 is changed to XCSE7331 means to hold the gate or guard closed. A separate • To order devices tapped for M20 x 1.5 for ISO cable gland: locking or latching mechanism must be used to hold Change the last character in the part number to 2 door closed. For example: XCSE7333 is changed to XCSE7332 • The safety interlock switch must not be used as a File E164353 File LR 44087-94 mechanical stop for the moving guard. A separate CCN: NKCR Class 3211-03 mechanical stop must be provided. • The actuating key must not be used as a gate guiding device. Install a guide for the guard to ensure proper TM alignment. For additional information, reference Catalog # 9007CT9702R2/00 or D-FAX # 1619. Discount © 2000 Square D T 23-8 All Rights Reserved Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com MACHINE SAFEGUARDING 23 PRODUCTS 12 11 22 21 22 21 22 21 12 11 22 21 32 31 22 21 14 13 32 31 22 21 32 31 14 13 34 33 14 13 32 31 14 13 34 33 Components for Machine Safety Applications XCS Safety Interlock References of Accessories and Spare Parts Description For use with Supply voltage Reference Weight Price Indicator light module, 1 24/48 VAC or VDC XCS-Z31 1.4 oz (0.040 kg) $43.00 XCS-A orange LED with cover, XCS-B seal, and 2 mounting XCS-C 110/240 VAC XCS-Z32 1.4 oz (0.040 kg) $43.00 screws 24/48 VAC or VDC XCS-Z41 6.125 oz (0.175 kg) $60.00 XCS-E53 kk 110/240 VAC XCS-Z45 6.125 oz (0.175 kg) $60.00 24/48 VAC or VDC XCS-Z42 6.125 oz (0.175 kg) $60.00 XCS-E55 kk Indicator light module, 110/240 VAC XCS-Z46 6.125 oz (0.175 kg) $60.00 1 orange LED + 1 green LED with cover, seal, 4 mounting screws, 24/48 VAC or VDC XCS-Z43 6.125 oz (0.175 kg) $60.00 and lock c XCS-E73 kk 110/240 VAC XCS-Z47 6.125 oz (0.175 kg) $60.00 24/48 VAC or VDC XCS-Z44 6.125 oz (0.175 kg) $60.00 XCS-E75 kk 110/240 VAC XCS-Z48 6.125 oz (0.175 kg) $60.00 Positions of Tubular High Description For use with Security key withdrawal Reference Weight (kg) Price from lock LOCK: yes/UNLOCK: yes XCS-Z51 0.875 oz (0.025 kg) $25.00 XCS-E53 kk LOCK: yes/UNLOCK: no XCS-Z55 0.875 oz (0.025 kg) $25.00 LOCK: no/UNLOCK: yes XCS-Z59 0.875 oz (0.025 kg) $25.00 LOCK: yes/UNLOCK: yes XCS-Z52 0.875 oz (0.025 kg) $25.00 XCS-E55 kk LOCK: yes/UNLOCK: no XCS-Z56 0.875 oz (0.025 kg) $25.00 LOCK: no/UNLOCK: yes XCS-Z60 0.875 oz (0.025 kg) $25.00 LOCK: yes/UNLOCK: yes XCS-Z53 0.875 oz (0.025 kg) $25.00 XCS-E73 kk LOCK: yes/UNLOCK: no XCS-Z57 0.875 oz (0.025 kg) $25.00 LOCK: no/UNLOCK: yes XCS-Z61 0.875 oz (0.025 kg) $25.00 Lock (+ 2 keys) mounted on cover, with seal and 4 mounting screws LOCK: yes/UNLOCK: yes XCS-Z54 0.875 oz (0.025 kg) $25.00 XCS-E75 kk LOCK: yes/UNLOCK: no XCS-Z58 0.875 oz (0.025 kg) $25.00 LOCK: no/UNLOCK: yes XCS-Z62 0.875 oz (0.025 kg) $25.00 LOCK: yes/UNLOCK: yes XCS-Z63 0.875 oz (0.025 kg) $25.00 XCS-E83 kk LOCK: yes/UNLOCK: no XCS-Z64 0.875 oz (0.025 kg) $25.00 LOCK: no/UNLOCK: yes XCS-Z65 0.875 oz (0.025 kg) $25.00 LOCK: yes/UNLOCK: yes XCS-Z66 0.875 oz (0.025 kg) $25.00 XCS-E85 kk LOCK: yes/UNLOCK: no XCS-Z67 0.875 oz (0.025 kg) $25.00 LOCK: no/UNLOCK: yes XCS-Z68 0.875 oz (0.025 kg) $25.00 XCS-A, XCS-B, Padlock Attachment XCS-Z90 3.00 oz (0.063 kg) $22.00 XCS-C, XCS-E XCS-A, Set of 10 blanking plugs XCS-B, XCS-Z27 1.75 oz (0.050 kg) $5.00 for operating head slot XCS-C, XCS-E Set of 10 pairs of Tubular XCS-C, XCS-Z90 XCS-Z25 3.5 oz (0.100 kg) $30.00 High Security keys XCS-E Connectors The XCS safety interlocks are av ailable in a wide variety of Mini and Micro connectors in many different wiring schemes (for a partial listing, refer to Catalog 9007CT9702). Connectors are available as factory installed options, but are not available as separate components. For mating connector cables, refer to page 18-10. Description Price Adder 3 pin through 6 pin Mini or Micro connector $64.00 7 pin through 9 pin Mini connector $94.00 c Lock supplied as standard with XCSE switches. Key withdrawal in both LOCK and UNLOCK positions. The only replacement parts or components available are covers and LED indicator modules. These devices are not to be repaired or adjusted. The complete switch should be replaced. TM For additional information, reference Catalog # 9007CT9702R2/00 or D-FAX # 1619. Discount © 2000 Square D T 3/00 Schedule 23-9 All Rights Reserved Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com MACHINE SAFEGUARDING 23 PRODUCTS Components for Machine Safety Applications XCS Safety Interlock Plastic, double insulated, turret head c, type XCS-PA and XCS-TA XCS-PA conduit entry tapped 1/2” NPT. XCS-TA conduit entry tapped for 1/2” conduit adapto r. References and Characteristics Type of switch Without locking of actuating key References of switches without actuating key (Direct opening N.C. contacts meets the IEC and EN requirements for positive opening contacts per IEC 947-5-1 section 3, EN 60 947-5-1.) N/C + N/O N.C. + N.O. + N.O. break before make, XCS-PA593 (2 N.O. staggered) XCS-TA593 slow break u a slow break ua N/O + N/C N. C. + N.C. + N.O. make before break, XCS-PA693 (N. O. staggered) XCS-TA793 slow break u sl ow breakua N/C + N/C N.C. + N.C. + N.C. slow break u XCS-PA793 XCS-TA893 slow break u Weight oz. (kg) 3.4 (0.095) Weight oz. (kg) 6.7 (0.190) Price $49.00 Price $55.00 c 90° increments throughout 360° u Schematic diagrams shown represent the contact states while the actuating key is inserted in the head of the switch. a The N/O contacts will close after the N/C contacts open. They do not change state simultaneously. The N.C. contacts only should be used in the safety control circuit. The N.O. contacts are provided solely for signalling – NOT for safety functions. Neither replacement parts nor components are available. These devices are not to be repaired or adjusted. The complete switch should be replaced. References of actuating keys and guard retaining device Description Straight key Wide key Pivoting key Right-angled key Guard retaining device p For switches XCS-PA, XCS-Z11 XCS-Z12 XCS-Z13 XCS-Z14 XCS-Z21 XCS-TA, and XCS-TE Weight oz. (kg) 0.5 (0.015) 0.5 (0.015) 3.0 (0.085) 0.9 (0.025) 3.0 (0.085) Price $4.00 $4.00 $20.00 $4.00 $10.00 p Only for use with actuating keys XCS-Z12 and XCS-Z13. The guard retaining device is used to provide additional force to hold the door or gate closed. One of the two parts is a plate that mounts to the head of the switch, and the other is a magnet assembly that is mounted with the actuating key. The magnet and plate act as a magnetic catch to aid in keeping the door closed. This assembly increases the force required ot remove the key. References of supplementary accessories Description Reference Weight oz. (kg) Price Set of 10 blanking plugs for operating head slot XCS-Z28 1.8 (0.050) $5.00 Padlock Attachment XCS-Z91 2.0 (0.057) $22.00 The devices above are available with metric conduit. • To order devices tapped for 11mm cable gland, conforming to NF C68-300 (DIN Pg 11): Change the last character in the part number to 1 For example: XCSPA593 is changed to XCSPA591 • To order devices tapped for M16 x 1.5 for ISO cable gland: XCS-Z91 Change the last character in the part number to 2 For example: XCSPA593 is changed to XCSPA592 When designing a door or gate guarding system, these guidelines must be followed: The N.C. contacts only should be used in the safety control circuit. The N.O. contacts are provided solely for • The actuating key alone must not be used as the sole signalling – NOT for safety functions. means to hold the gate or guard closed. A separate locking or latching mechanism must be used to hold Neither replacement parts nor components are available. These devices are not to be repaired or adjusted. The door closed. complete switch should be replaced. • The safety interlock switch must not be used as a mechanical stop for the moving guard. A separate mechanical stop must be provided. • The actuating key must not be used as a gate guiding File LR 44087-94 device. Install a guide for the guard to ensure proper File E164353 Class 3211-03 alignment. CCN: NKCR TM For additional information, reference Catalog # 9007CT9702R2/00 or D-FAX # 1619. Discount T © 2000 Square D Schedule 23-10 3/00 All Rights Reserved Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com MACHINE SAFEGUARDING 23 PRODUCTS 22 21 14 13 12 11 22 21 22 21 14 13 12 11 22 21 22 21 22 21 32 31 14 13 32 31 14 13 34 33 XCS Safety Interlock Selection Plastic, Double Insulated, Turret Head c, Type XCS-TE, 1/2” NPT Conduit References of Switches Without Actuating Key (select actuating key from page 23-10) Direct opening N.C. contacts meet the IEC and EN requirements for positive opening contacts per IEC 947-5-1, EN 60947-5-1; and NEMA ICS-5, part 6 (direct opening action.) Type of switch With interlocking, locking by electromagnet q Locking Without Power. Actuating key locks into switch when inserted. This is typically preferred as the Type of interlocking door is secured regardless of electrical power availability or failure. Applying power to the electromagnet will unlo ck actuating key and allow it to be removed from the switch. Supply voltage of electromagnet 24 VAC or VDC 120 VAC or VDC 230 VAC or VDC N.C. + N.O. break before make XCS-TE5313 XCS-TE5333 XCS-TE5343 slow break au N.O. + N.C. make before break XCS-TE6313 XCS-TE6333 XCS-TE6343 slow break u N.C. + N.C. XCS-TE7313 XCS-TE7333 XCS-TE7343 slow break u Weight oz. (kg) 13 (0.360) 13 (0.360) 13 (0.360) Price $130.00 $130.00 $130.00 Type of switch With interlocking, locking by electromagnet q Locking with Power. Actuating key is locked into switch only when actuating key is inserted and power is applied to the electromagnet. Door or guard is not locked in the event of a power failure or when power Type of interlocking is removed from the electromagnet. Removing power to the electromagnet will unlock actuating key and allow it to be removed from the switch. Note: Locking with Power devices do not meet European standards regarding the safety of machinery, especially EN 1088 regarding guard locking. European standards do not allow a “locking with power” function for gate or door guarding/locking. Locking without power devices meet European requirements, and should be used when machinery is to be shipped to Europe or where machinery must meet European standards. Supply voltage of electromagnet 24 VAC or VDC 120 VAC or VDC 230 VAC or VDC N.C. + N.O. break before make XCS-TE5513 XCS-TE5533 XCS-TE5543 slow break au N.O. + N.C. make before break XCS-TE6513 XCS-TE6533 XCS-TE6543 slow break u N.C. + N.C. XCS-TE7513 XCS-TE7533 XCS-TE7543 slow break u Weight oz. (kg) 13 (0.360) 13 (0.360) 13 (0.360) Price $150.00 $150.00 $150.00 c 90° increments throughout 360° q A special tool included with the switch enables the forced opening of the interlocking device, allowing opening of the N.C. safety contacts and subsequent actuating key withdrawal. u Schematic diagrams shown represent the contact states while the actuating key is fully inserted and engaged in the head of the switch. a The N.O. contacts will close after the N.C. contacts open. They do not change state simultaneously. The N.C. contacts only should be used in the safety control circuit. The N.O. contacts are provided solely for signalling – NOT for safety functions. Neither replacement parts nor components are available. These devices are not to be repaired or adjusted. The complete switch should be replaced. The devices above are available with metric conduit. – To order devices tapped for 11mm cable gland, conforming to NFC 68-300 (DIN Pg 11): Change the last character in the part number to 1. For example: XCSTE5513 is changed to XCSTE5511. – To order devices tapped for M16 x 1.5 for ISO cable gland: Change the last character in the part number to 2. For example: XCSTE5513 is changed to XCSTE5512. When designing a door or gate guarding system, these guidelines must be followed: – The actuating key alone must not be used as the sole means to hold the gate or guard closed. A separate locking or latching mechanism must be used to hold door closed. – The safety interlock switch must not be used as a mechanical stop for the moving guard. A separate mechanical stop must be provided. – The actuating key must not be used as a gate guiding device. Install a guide for the guard to ensure proper alignment. – The actuating key must not be used as a means for earth grounding. File LR 44087-94 File E164353 Class 3211-03 CCN: NKCR TM For additional information, reference Catalog # 9007CT9702R2/00 or D-FAX # 1619. Discount © 2000 Square D T 3/00 Schedule 23-11 All Rights Reserved Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com 14 13 14 13 22 21 22 21 12 11 12 11 22 21 22 21 22 21 22 21 14 13 14 13 MACHINE SAFEGUARDING 23 PRODUCTS XCS Safety Interlock Selection Plastic, Double Insulated, Turret Head c, Type XCS-PL, XCS-PR, XCS-TL, and XCS-TR, 1/2" NPT Conduit References of Switches with Rotary Lever Direct opening N.C. contacts meet the IEC and EN requirements for positive opening contacts per IEC 947-5-1, EN 60947-5-1; and NEMA ICS-5, part 6 (direct opening action.) Type of lever Elbowed (flush with rear of switch) Straight Rotary Shaft Orientation of operating lever To left Centered To right To right or to left Centered Length 30 mm f N.C. + N.O. break before make XCS-PL593 XCS-PL583 XCS-PL573 XCS-PL563 XCS-PL553 XCS-PR553 slow breakua N.C. + N.C. XCS-PL793 XCS-PL783 XCS-PL773 XCS-PL763 XCS-PL753 XCS-PR753 slow break u Weight oz (kg) 3.9 (0.110 kg) 3.9 (0.110 kg) 3.9 (0.110 kg) 3.9 (0.110 kg) 3.9 (0.110 kg) 4.2 (0.120) Price $54.00 $54.00 $54.00 $54.00 $54.00 $60.00 Orientation of operating lever To left Centered To right To right or to left Centered Length 30 mm f N.C. + N.O. + N.O. (2 N.O. staggered) XCS-TL593 XCS-TL583 XCS-TL573 XCS-TL563 XCS-TL553 XCS-TR553 slow breakua N.C. + N.C. + N.O. (N.O. staggered) XCS-TL793 XCS-TL783 XCS-TL773 XCS-TL763 XCS-TL753 XCS-TR753 slow breakua N.C. + N.C. + N.C. XCS-TL893 XCS-TL883 XCS-TL873 XCS-TL863 XCS-TL853 XCS-TR853 slow break u Weight oz (kg) 5.6 (0.160 kg) 5.6 (0.160 kg) 5.6 (0.160 kg) 5.6 (0.160 kg) 5.6 (0.160 kg) 5.5 (0.155) Price $60.00 $60.00 $60.00 $60.00 $60.00 $66.00 c 90° increments throughout 360° u Schematic diagrams shown represent the contact states when the rotary lever is in positions as indicated in diagrams directly above the part numbers in selection table. f References listed have a shaft that is 1.18 in (30 mm) long. To order a switch with a shaft that is 3.15 in (80 mm) long, replace the second digit, 5, with a 6. For example: XCS-PR553 is changed to XCS-PR563. Add $6 to the price for the longer shaft. a The N.O. contacts will close after the N.C. contacts open. They do not change state sim ultaneously. The devices above are available with metric conduit. – To order devices tapped for 11mm cable gland, conforming to NFC 68-300 (DIN Pg 11): Change the last character in the part number to 1. For example: XCSPL593 is changed to XCSPL591. – To order devices tapped for M16 x 1.5 for ISO cable gland: Change the last character in the part number to 2. When designing a door or gate guarding For example: XCSPL593 is changed to XCSPL592. system, these guidelines must be followed: The N.C. contacts only should be used in the safety control circuit. The N.O. contacts are provided solely for – The actuating key alone must not be used as signalling – NOT for safety functions. the sole means to hold the gate or guard closed. A separate locking or latching mecha- Neither replacement parts nor components are available. These devices are not to be repaired or adjusted. The nism must be used to hold door closed. complete switch should be replaced. – The safety interlock switch must not be used as a mechanical stop for the moving guard. A separate mechanical stop must be provided. – The actuating key must not be used as a gate File E164353 File LR 44087-94 guiding device. Install a guide for the guard to CCN: NKCR Class 3211-03 ensure proper alignment. TM For additional information, reference Catalog # 9007CT9702R2/00 or D-FAX # 1619. Discount © 2000 Square D T Schedule 23-12 All Rights Reserved 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com MACHINE SAFEGUARDING 23 PRODUCTS 12 11 22 21 22 21 14 13 12 11 22 21 32 31 14 13 22 21 22 21 32 31 14 13 34 33 XCK J Safety Interlock Actuating keys are ordered Without Locking separately. Actuating key is not locked into device when inserted. Contact Catalog Price Type Number N.O.+N.C. break-before-make XCKJ5970 $97.00 N.O.+N.C. make-before-break XCKJ6970 97.00 N.C.+N.C. simultaneous XCKJ7970 97.00 With Locking XCK J5970 Actuating key is locked into switch when inserted. N.O.+N.C. break-before-make XCKJ5910 $150.00 Pushbutton N.C.+N.C. simultaneous XCKJ7910 150.00 Ronis key lock (no. 520) N.O.+N.C. break-before-make XCKJ5930 187.00 XCK J5930 Electromagnet An electromagnet is used to lock the actuating key into switch, either with power or without power applied to the electromagnet. XCK-J5910 To construct the part number, start with either XCK-J59 (for N.O. and N.C.) or XCK-J79 (for N.C. and N.C.) as the base. Then add the appropriate code for desired configuration for: latching, actuation, voltage, indicator, and connector. Latching Actuation Voltage Indicator Connector Price XCK J59 XCK J79 XCK J5957B0 Locking Without Power Without Ronis key release 5 $275.00 With Ronis key release Right 2 349.00 Key position: Left 0 349.00 Back 4 349.00 Front 6 349.00 Locking With Power 8 352.00 Key actuation Electromagnet connector Price Adder Left 1 – From front Right 2 – Back 3 – Left 4 – From right Front 5 – Right 6 – XCK-P/T From left Front 7 – Left 8 – From back Right 9 – Electromagnet supply voltage Price Adder 24 VDC B – 110 VAC F 31.70 Pilot lights Price Adder No pilot lights 0 – File LR44087 LED 24VDC (1 LED: contact state) 2 45.40 Class 3211-03 With pilot lights Neon 110VAC (2 neon lamps) 3 45.40 Ministyle 5 pin. Used without pilot lights. For wiring diagram, see Prod Catalog. -547 68.00 Connector options Ministyle 6 pin . Used with pilot lights. For wiring diagram, see Product Catalog. -647 68.00 Actuating Keys for XCK-J Description Catalog Number Price Obsolescence Note: Straight actuating key ZCK-Y071 $15.80 Perpendicular actuating key ZCK-Y081 15.80 All XCK-J Safety Interlock Adjustable actuating key ZCK-Y091 31.70 devices are in obsolescence and will become obsolete at Sliding bolt actuating key ZCK-Y101 140.00 various times throughout the XCK-P/T year 2000. We recommend 1 Cable entry, slim body, 4 direction indexing head XCKP591 $52.00 the use of the XCS Safety 2 Cable entries, short body, 4 direction indexing head XCKT591 59.00 Interlocks listed on pages 23-6 through 23-12. To determine Actuating Keys for XCK-P/T which XCS Safety Interlock to Straight actuating key XCKY01 $ 4.20 use, refer to Cross Reference Perpendicular actuating key XCKY02 4.20 Document 9007PD9701, or TM Adjustable actuating keyt XCKY03 29.50 D-FAX # 2510. t Key delivered for vertical movement. Can be field modified for horizontal movements. TM For additional information, reference Catalog # 9007CT9702R2/00 or D-FAX # 1619. Discount © 2000 Square D T Schedule 3/00 All Rights Reserved 23-13 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com OBSOLESCENT MACHINE SAFEGUARDING 23 PRODUCTS

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the XCK-Y03 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Telemecanique ATS01N232QN 380-415VAC, 32 Amp Soft Start Relay

product

Telemecanique DF6AB10 Fuse Holder, DF6 - 1P - 32 A - for fuse NFC 10 x 38 mm

product

Telemecanique GB2-CB07 2 Amp, 1 Pole Circuit Protector

product

Telemecanique GBS PREVENTA Series Safety Relays

product

Telemecanique GNKL PREVENTA Series Safety Relays

product

Telemecanique J20C40 Relay - RELAY CONTROL WITH CONVERTIBLE CONTACTS