TELEMECANIQUE RM3 Series
Description
TELEMECANIQUE RM3 Series Relays
Part Number
RM3 Series
Price
Request Quote
Manufacturer
TELEMECANIQUE
Lead Time
Request Quote
Category
TBD
Datasheet
Extracted Text
RM3 Specialty Relays ® File 8430 RM3 Specialty Relays Table of Contents Contents RM3 Measurement and Control Relays ................................................................ 2-5 RM3JA2 Current Measurement Relays ................................................................. 6-9 RM3JA1 Current Measurement Relays ............................................................. 10-13 RM3UA2 Voltage Measurement Relays ............................................................ 14-17 RM3UA1 Voltage Measurement Relays ............................................................ 18-21 RM3TG2 3-Phase Supply Relays ...................................................................... 22-25 RM3TR1 3-Phase Supply Relays ...................................................................... 26-29 RM3TA2 3-Phase Supply Relays....................................................................... 30-33 RM3TAR1 3-Phase Supply Relays .................................................................... 34-37 RM3LG2 Liquid Level Control Relay .................................................................. 38-41 RM3LA1 Liquid Level Control Relay .................................................................. 42-45 RM3PA1 Insulation Control Relay...................................................................... 46-49 RM3EA1 Sensitive Contact Protection Relay .................................................... 50-53 1 RM3 Specialty Relays Selection guide Current measurement Voltage measurement 3-phase supply control Applications Overcurrent Undercurrent and Overvoltage Undervoltage or overcurrent overvoltage Adjustable threshold Adjustable thresholds Adjustable thresholds Detects: 0.003 to 1 A 0.003 to 1 A 0.05 to 5 V proper phase or 0.3 to 15 A or 1 to 100 V rotation and Measurement or depending on relay or 30 to 500 V phase loss control depending on relay 24 Vac 24 to 240 Vac or dc 24 Vac 24 to 240 Vac or dc 220 to 500 Vac 42 to 48 Vac 110 to 130 Vac 42 to 48 Vac 110 to 130 Vac Supply voltage 110 to 130 Vac 220 to 240 Vac 110 to 130 Vac 220 to 240 Vac 220 to 240 Vac 380 to 415 Vac 220 to 240 Vac 380 to 415 Vac 1 Form C 2 Form C 1 Form C 2 Form C 2 Form C Number of output relay contacts Energized when threshold is exceeded De-energized on detection of a fault Output relay state Green LED : Supply voltage is present to the relay Yellow LED : Relay Yellow LED : Relay has been energized. has been energized Display Fixed 80 ms Adjustable Fixed 80 ms Adjustable None Built-in time delay 0.05 to 30 s 0.05 to 30 s .89 inches 1.77 inches .89 inches 1.77 inches .89 inches Width 22.5 mm 45 mm 22.5 mm 45 mm 22.5 mm Catalog Number RM3JA2 RM3JA1 RM3UA2 RM3UA1 RM3TG2 Pages 6 to 9 10 to 13 14 to 17 18 to 21 22 to 25 2 RM3 Specialty Relays Selection guide Liquid level Insulation Protection of control control sensitive contacts Control : Control : Control : Measurement of liquid resistance Adjustable threshold Control of rotational direction asymmetry of asymmetry of by submersible probes 1 to 110 kΩ contact closing and total failure of phases, failure phases, phase one or more phases, of one or more failure, rotational undervoltage, phases rotational direction of overvoltage, 220 direction of phases. phases, 400, 500, 380 to 420 220 to 240 V 220 to 240 V 430 to 500V 380 to 415 V 380/415V to 500V 110 to 130 Vac 220 to 240 Vac 110 to 130 Vac 24 Vac 24 to 240 Vac or dc 24 to 240 Vac or dc 24 Vac 160 to 300 Vac 380 to 415 Vac 220 to 240 Vac 110 to 130 Vac 110 to 130 Vac 110 to 130 Vac 110 to 130 Vac 220 to 240 Vac 380 to 415 Vac 220 to 240 Vac 220 to 240 Vac 220 to 240 Vac 220 to 240 Vac 300 to 500 Vac 380 to 415 Vac 380 to 415 Vac 380 to 415 Vac 380 to 415 Vac 2 Form C 1 Form C 2 Form C 1 Form C 2 Form C 1 Form C 2 Form C De-energized on detection of a fault Energized when Energized when Energized on high level electrode high level electrode detection of immersed. immersed. a fault. De-energized when De-energized when low level electrode low level electrode not immersed. not immersed. Green LED : Yellow LED : Green LED : Green LED : Green LED : Supply voltage is present. Supply voltage is Relay has been Supply voltage is Supply voltage is Yellow LED : Relay has been energized. present. energized. present. present. Yellow LED : Yellow LED : Yellow LED : Relay has been Relay has been Relay has been energized. energized. energized. 3 red LEDs : 2 red LEDs : faults have faults have occurred. occurred. Adjustable Fixed 500 ms Adjustable Fixed Adjustable None None or adjustable 0.1 to 10 s 0.1 to 10 s 250 ms 0.1 to 10 s 0.05 to 30 s 1.77 inches .89 inches 1.77 inches .89 inches 1.77 inches 1.77 inches 1.77 inches 45 mm 22.5 mm 45 mm 22.5 mm 45 mm 45 mm 45 mm RM3TR1 RM3TA2 RM3TAR1 RM3LG2 RM3LA1 RM3PA1 RM3EA1 26 to 29 30 to 33 34 to 37 38 to 41 42 to 45 46 to 49 50 to 53 3 RM3 Specialty Relays General Application Data Environment Conforming to standards IEC 801 part 1-4 level III IEC 68 part 2-3/2-6 VDE 0435 part 303, 4.8.3/class II and 303, 4.2.1/class I min. 2.5 kV VDE 57160 part 0160/5.84 paragraph 4.8.8 VDE 0110/overvoltage category III Approvals UL listed file E39281 guide E164353 CSA, GV Ambient air temperature Storage ˚F -40 to 185 around the device (˚C) (-40 to 85) Operation ˚F -13 to 140 (˚C) (-25 to 60) On-load factor 100% Supply voltage range -15% to +10% of rated supply voltage Insulation voltage Between input and output kV 2.5 Vibration resistance Conforming to IEC 68-2-6 10 gn/F = 55 Hz/a = ± 0.95 mm 2h per level Shock resistance 10 gn Degree of protection Conforming to VDE 0106 (part 100) and VBG 4 for the terminal block Terminals IP 20 protected against direct finger contact Enclosure IP 50 Settings Direct By absolute scales Operating status indication Green LED on Supply voltage is present to terminals A1 and A2 Yellow LED on Output relay has been energized Red LED on Indicate that a fault has occurred Connection By captive recessed All products +/- screws Wire Combinations Stranded wire AWG ≤ 2 #14 (≤ 2 x 2.5) without cable end 2 ) ≤ 2 #14 (≤ 2 x 2) with cable end (mm Mounting positions Any Mounting method Clip-on On 35mm DIN3 mounting track Cover accessory Optional To reduce the chance of unauthorized changing of settings Housing, terminal covers and Self-extinguishing plastic Class V0 or V1 (UL 94) top cover material Product Carton Recyclable Output relay characteristics Mechanical durability In millions of operating cycles 30 Minimum switching capacity Resistive circuit 17 V and 10 mA Galvanic separation between All products input and measurement circuits 4 RM3 Specialty Relays RM3 Measurement and Control Relays General Application Data Output characteristics Load on a.c. supply Electrical durability of contacts, in millions of operating cycles 220 V 50 Hz AC-1, 360 operating cycles/hour Millions of operating cycles 6 10 9 8 7 6 5 4 3 2 5 10 123 45 6 7 8 Amperes Reduction factor K for inductive loads (to be applied to the values obtained above) 1.0 0.9 0.8 0.7 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Cos ϕ Load on d.c. supply Load limit curve (resistive load) V 300 200 100 80 60 50 40 30 20 10 0.1 0.3 0.5 0.8 21 3 4 6 80 0.2 0.4 0.6 1 Amperes Note: When used with a d.c. contactor or relay, it is recommend that a freewheel diode be connected in parallel to the coil. + RM3 K – 5 RM3 Specialty Relays RM3JA2 Current Measurement Relays Operating Principles This device is used anywhere it is important to detect when a preset a.c. or d.c. current threshold is exceeded. This relay can be used to monitor currents between 3mA and 1A. Some examples of applications for this relay are: - To detect whether a conveyor is loaded or not. - To detect a load on a pump. - To detect a fan belt breaking. - To monitor loading of single phase motors. - To monitor heating and lighting circuits. Operating principles • Apply the appropriate supply voltage (U supply) to terminals A1 and A2. This supplies power to the electronics inside this device. • The current to be monitored is connected to terminal B1 or B2 or B3 (depending on current to be monitored) and RM3JA2 terminal C. • The output relay terminal (15-common, 16-normally close contact, 18-normally open contact) is used to signal that the current is or is not above the preset current threshold setting. • The current threshold setting (IS1)(refer to the diagrams below) is set to the current above which it is desired to have the output relays change state. • The hysteresis needs to be set. Hysteresis is the difference between the current threshold setting and the dropout current setting (IS2) of the output relay. It is expressed as a percentage: h= (IS1 - IS2)/IS1 1 Hysteresis setting, 5 to 30% 2 Current threshold setting (IS1) If the current to be monitored is connected to: RM3 JA2 • B1 and C = Use the white scale times 0.001 1 (3 to 30mA) A1 A2 • B2 and C = Use the yellow scale times 0.001 16 (10 to 100mA) 15 18 • B3 and C = Use the yellow scale times 0.01 (0.1 to 1A) R The yellow LED labeled with an R indicates that the 2 output contacts have been energized when it is R illuminated. U U The green LED labeled with a U (Voltage) indicates that supply voltage is present to the RM3 relay when illuminated. Functional diagram U supply A1-A2 B1, B2, B3 C RM3-JA2 IS1 Load U drop < 1 V IS2 Current measured 1 measurement 15-18 Relay 15-16 t ≤ 80 ms < t t : measurement cycle • If the supply voltage (U supply) is not applied to terminals A1 and A2, the output relays will be in its deenergized state (contact 15-16 will be closed and contact 15-18 will be open). • When supply voltage is applied to terminal A1 and A2, the output relay will not change state until the current has exceeded the current threshold setting (IS1) and the current remains above the current threshold setting (IS1) level for more than the measuring cycle of ≤ 80 milliseconds. • After the output relay has changed state, it will remain energized unless the current falls below the dropout current setting (current threshold setting minus the hysteresis) or supply voltage is lost from terminals A1 or A2 or the measured current exceeds the upper limits of the RM3 relay, which results in damage to the RM3 relay. • The measure range of this relay can be extended by: - Using a current transformer and connecting the secondary to the terminals on the RM3 relay. - Connecting a resistor in parallel with the measuring input (see the next page for an example). 6 Measurement circuit RM3 Specialty Relays RM3JA2 Current Measurement Relays Wiring, Approximate Dimensions, and Setup Information Wiring C A1 15 B3 A1-A2 Supply voltage B1 B2 Connection and current values to be measured B1, B2, Currents to be measured RM3JA211 B1-C 3 to 30 mA B3, C (see table to the right) B2-C 10 to 100 mA 15-18 Form C contact of output C B3-C 0.1 to 1 A 15-16 relay 18 16 A2 Approximate dimensions Inches Dimensions MM 3.94 / 100 .885/22.5 Setup information • Setup example is based on the following information : - Overcurrent threshold to be measured is 0.8A. • Using page 8, an RM3JA211FG7 relay would be selected because of the - Dropout current threshold is 0.6 A. 120 Vac supply voltage and it has a measurement range of 3mA to 1A. - The supply voltage is 120 Vac • Wire the RM3JA211FG7 relay as explained under operating principles on the previous page. • Set the current threshold potentiometer (2) to 80 on the yellow scale. Current RM3 JA2 is being measured on terminals B3 and C, which means you use the yellow 1 A1 A2 scale times 0.01 (80x0.01=0.8A). 16 • Set the hysteresis potentiometer to 25 15 18 h = (IS1-IS2)/IS1 2 (0.8-0.6)/0.8=0.25 or 25% R U d.c. or a.c. supply: Simply connect a resistor “Rs” to terminals B1-C (or B2, \B3-C) on the measuring • Example of extending the measuring range input. RM3-JA I Im B1 The relay energization threshold will be towards the middle of the setting Ri potentiometer range if the value of Rs is in the region of : Rs = Ri (2I/Im) - 1 Rs where: Ri Internal resistance of input B1-C C Im Maximum value of the threshold setting range I Current threshold to be measured 2 Power dissipated by Rs : P = Rs (I -Im/2) Application : use of relay RM3JA211••• (10 to 100 mA). Connection B2-C to measure a threshold of 1 A, knowing that Ri = 10 Ω for this rating and that Im = 100 mA 10 0.1 2 The value Rs will be : = 0.526 Ω P = (1 - ) x 0.526 = 0.47 W (2 x 1/0.1) - 1 2 Select a resistor Rs capable of dissipating at least twice the calculated value, i.e. 1 W for this example, in order to limit the temperature rise. 7 B1 A1 B2 A2 B3 16 18 15 3.05 / 77.5 RM3 Specialty Relays RM3JA2 Current Measurement Relays Ordering Information Current to be measured Control Circuit Catalog Approximate depending on connection Voltage Number Weight ac or dc 50/60 Hz lb. / (kg) 3 to 30 mA 24 RM3JA211B7 0.39/(0.175) 10 to 100 mA 42-48 RM3JA211DE7 0.39/(0.175) 0.1 to 1 A 110-130 RM3JA211FG7 0.39/(0.175) 220-240 RM3JA211MU7 0.39/(0.175) RM3JA2 Accessories (to be ordered separately) Description Catalog Approximate Number Weight lb. / (kg) Sealing cover LA9RE02 0.01/(0.003) Replacement Marking Tab LA9D92 0.01/(0.001) LA9RE02 8 RM3 Specialty Relays RM3JA2 Current Measurement Relays Application Data Control circuit characteristics Rated supply voltage (Un) Vac 50/60 Hz V 24 42 to 48 110 to 130 220 to 240 Average consumption at Un Vac VA 2.1 2.9 2.4 3.2 Output relay and operating characteristics Number of C/O (Form C) contacts 1 Output relay state Energized when current threshold exceeded Rated operational voltage IEC V 250 (switching) UL V 300 Conventional thermal current IEC A 4 UL A 5 Rated breaking capacity AC-15, 220 V A 1.5 NEMA B300 Time delay None Switching threshold drift Depending on ≤ 0.06 % per degree centigrade permissible ambient temperature Within the supply ≤ 0.5 % voltage range (85% to 110% of Un) Hysteresis Adjustable 5 to 30 % of the current threshold setting Measuring cycle ms ≤ 80 Operating status indication Green LED on Supply Voltage (Un) is present to the relay. Yellow LED on Relay energized (current threshold exceeded) Measuring input characteristics Internal input resistance Measurement range Internal input Permissible continuous Permissible overload and permissible overload Vac 50-60 Hz and Vdc resistance Ri overload for t ≤ 3 s depending on the current (Not repetitive) measurement ranges 3 to 30 mA 33 Ω 50 mA 200 mA 10 to 100 mA 10 Ω 150 mA 0.5 A 0.1 to 1 A 1 Ω 1.5 A 5 A 9 RM3 Specialty Relays RM3JA1 Current Measurement Relays Operating Principles This device is designed to detect when a preset current threshold is exceeded, on a.c. or d.c. supply. The RM3JA1••MW relay can monitor overcurrent or undercurrent. All the other relays can only monitor overcurrent. These relays can be used to monitor currents between 3 mA to 15 A. Some examples of applications for these relays are: - To detect whether a conveyor is loaded or not - To monitor the loading of a single phase motor - To detect a load on a pump - To monitor heating and lighting loads - To detect a fan belt breaking Operating principles Apply the appropriate supply voltage (U Supply) to terminals A1 and A2. This supplies power to the electronics inside • the device. The current to be monitored is connected to terminal B1 or B2 or B3, depending on current to be monitored, and • terminal C. The output relay terminals (15 and 25 -Common, 16 and 26 -Normally closed contact, and 18 and 28- Normally open • contact) are used to signal that the current is or is not above the preset current threshold setting. The current threshold setting (IS1) (refer to the diagram below) is set to the current above which it is desired to have • the output relays change state. RM3JA1 The hysteresis needs to be set. Hysteresis is the difference between the current threshold setting and the dropout • current setting (IS2) of the output relays. It is expressed as a percentage: h = (IS1-IS2)/IS1. Hysteresis is adjustable between 5 and 30%. 1 Time delay range selector switch (0.05 to 1 sec. and 1.5 to 30 sec.). 2 Time delay setting. RM3 JA1 3 Hysteresis setting 5 to 30%. 1 A1 A2 4 Current threshold setting (IS1). 16 15 18 If the current to be monitored is connected to: 3 1s 26 • B1 and C = Use the yellow scale times 0.1 25 28 • B2 and C = Use the white scale times 1.0 4 • B3 and C = Use the yellow scale times 1.0 2 5 Undercurrent (UC) or Overcurrent (OC) selector switch. Uc MW relay. This is only available on the RM3JA1•• R 5 R The yellow LED labeled with an R indicates that the output U contacts have been energized when it is illuminated. U The green LED labeled with a U (voltage) indicates that supply voltage is present to the RM3 relay when illuminated. Functional diagram • If the supply voltage (U supply) is not applied to terminals A1 and A2, the output relays will be in the de-energized state (Contacts 15-16 and 25-26 will be closed and contacts 15-18 and 25-28 will be open). • If the RM3JA1••MW set to OC or any of the other RM3JA1 relays monitors a current greater than the threshold setting (IS1), the output relay will energize with or without time delay, depending on the relay chosen. When the current returns to a value IS2 below the threshold, depending on the hysteresis setting, the relay is instantaneously de- energized. • If the RM3JA1••MW relay set to UC monitors a current less than the threshold setting IS1, the output relay will energize with or without time delay, depending on the relay chosen. When the current returns to a value IS2 above the threshold, depending on the hysteresis setting, the relay is instantaneously de-energized. • A measuring cycle lasts only 80 ms, which allows rapid detection of changes in current. Function "OI" Function "UI" U supply A1-A2 U Supply A1-A2 IS2 IS1 IS1 Current measured IS2 Current Measured 15-18 15-18 Relay Relay 15-16 15-16 25-28 25-28 25-26 25-26 t < t t < t t: time delay B1, B2, B3 C RM3-JA Load U drop < 1 V Note : The measurement ranges can be extended by means of a current transformer, the secondary of which is connected to the terminals of the corresponding RM3, or by means of a resistor connected in parallel with the current being measured (see the next page for an example). 10 Measurement circuit RM3 Specialty Relays RM3JA1 Current Measurement Relays Wiring, Approximate Dimensions, and Setup Information Wiring C Connection and current values to be measured according to the type of RM3JA1 RM3JA1•1 B1-C 3 to 30 mA A1-A2 Supply voltage B2-C 10 to 100 mA A1 15 25 B1 B2 B3 B1, B2, Currents to be measured B3-C 0.1 to 1 A B3, C (see table to the right) st RM3JA1•2 B1-C 0.3 to 1.5 A 15-18 1 Form C contact of output 15-16 relay B2-C 1 to 5 A nd 25-28 2 Form C contact of output B3-C 3 to 15 A 16 18 28 26 C A2 25-26 relay Approximate dimensions Inches Dimensions MM 3.94 / 100 1.77 / 45 Setup information • Setup example of overcurrent based on the following information: - Overcurrent threshold to be measured is 13 amperes • Using page 12, an RM3JA112MW could be selected because it will work on - Output relay time delay : 5 sec 120 Vac 60 Hz, it has a range from 0.3 to 15 Amperes, and it has an - Reset current threshold : 11 A adjustable time delay. - Supply voltage : 120 Vac 60 Hz • Wire the relay as explained under operating principles on the previous page. • To setup the relay: RM3 JA1 Place the function selector 5 on Oc. 1 A1 A2 - Place the timing range selector 1 on 30 s. 16 - Set the time delay potentiometer 2 to 5 s on the yellow scale. 15 18 3 1s 26 - Set the current threshold setting potentiometer 4 to 13 on the yellow 25 28 scale. 4 - Set the hysteresis 3 to 15.4 % on the yellow scale. 2 (13 - 11)/13 = 2/13 = .154 = 15.4 %. Uc R 5 U d.c. or a.c. supply • Extending the measuring range Simply connect a resistor “Rs” to terminals B1-C (or B2, \B3-C) on the measuring input. RM3-JA I Im B1 The relay energization threshold will be towards the middle of the setting Ri potentiometer range if the value of RS is in the region of : Rs = Ri Rs (2I/Im) - 1 where: Ri Internal resistance of input B1-C C Im Maximum value of the threshold setting range I Current threshold to be measured 2 Power dissipated by Rs : P = Rs (I -Im/2) - Application: use of relay RM3JA111FG7 (10 to 100 mA). Connection B2-C to measure a threshold of 1 A, knowing that Ri = 10 W for this rating and that Im = 100 mA 10 0.1 2 x 0.526 = 0.47 W The value of Rs will be : = 0.526 Ω P = (1 - ) (2 x 1/0.1) - 1 2 Select a resistor “Rs” capable of dissipating at least twice the calculated value, i.e. 1 W for this example, in order to limit temperature rise. 11 A1 B1 B2 A2 B3 16 18 15 26 28 25 3.05 / 77.5 RM3 Specialty Relays RM3JA1 Current Measurement Relays Ordering Information Time delay Current to be measured Control Circuit Catalog Weight depending on connection Voltage Number Vac or Vdc 50/60 Hz lb./(kg) 24 to 240 Vac 3 to 30 mA or 24 to 240 Vdc RM3JA111MW 0.65/(0.295) Adjustable 10 to 100 mA 110 to 130 Vac RM3JA111FG7 0.65/(0.295) 0.05 to 30 s 0.1 to 1 A 220 to 240 Vac RM3JA111MU7 0.65/(0.295) 380 to 415 Vac RM3JA111QN7 0.65/(0.295) 24 to 240 Vac 0.3 to 1.5 A or 24 to 240 Vdc RM3JA112MW 0.65/(0.295) 1 to 5 A 110 to 130 Vac RM3JA112FG7 0.65/(0.295) 3 to 15 A 220 to 240 Vac RM3JA112MU7 0.65/(0.295) 380 to 415 Vac RM3JA112QN7 0.65/(0.295) RM3JA1 24 to 240 Vac 3 to 30 mA or 24 to 240 Vdc RM3JA101MW 0.65/(0.295) None 10 to 100 mA 110 to 130 Vac RM3JA101FG7 0.65/(0.295) 0.1 to 1 A 220 to 240 Vac RM3JA101MU7 0.65/(0.295) 380 to 415 Vac RM3JA101QN7 0.65/(0.295) 24 to 240 Vac 0.3 to 1.5 A or 24 to 240 Vdc RM3JA102MW 0.65/(0.295) 1 to 5 A 110 to 130 Vac RM3JA102FG7 0.65/(0.295) 3 to 15 A 220 to 240 Vac RM3JA102MU7 0.65/(0.295) 380 to 415 Vac RM3JA102QN7 0.65/(0.295) Accessories (to be ordered separately) Description Catalog Weight Number lb./(kg) Sealing cover LA9RM301 0.01/(0.005) Replacement Marking Tab LA9D92 0.01/(0.001) LA9RM301 12 RM3 Specialty Relays RM3JA1 Current Measurement Relays Application Data Control circuit characteristics Rated supply voltage (Un) Vac 50/60 Hz V 24 to 240 110 to 130 220 to 240 380 to 415 Vdc V 24 to 240 – – – Average consumption at Un Vac VA 2.2 to 6 4.8 3.5 4 Vdc W 2 – – – Output relay and operating characteristics Number of C/O (Form C) contacts 2 Output relay state Energized when current threshold exceeded Rated operational voltage IEC V 400 (switching) UL V 300 Conventional thermal current IEC A 5 UL A 5 Rated breaking capacity AC-15 230 V-3 A, 400 V-2 A NEMA B300 Time delay Adjustable on s 0.05 to 30 RM3JA11 Switching threshold drift Depending on permissible ≤ 0.06 % per degree centigrade ambient temperature Within the supply ≤ 0.5 % voltage range (85% to 110% Un) Time delay drift Within the supply ≤ 0.5 % voltage range (85% to 110% Un) Depending on ≤ 0.06 % per degree centigrade temperature Hysteresis Adjustable 5 to 30 % of the current threshold setting Measuring cycle ms ≤ 80 Operating status indication Green LED on Supply Voltage (Un) is present to the relay. Yellow LED on Relay energized (current threshold exceeded) Measuring input characteristics Internal input resistance Measurement range Internal input Permissible continuous Permissible overload and permissible overload Vac 50-60 Hz and Vdc resistance Ri overload for t ≤ 3 s depending on the current 3 to 30 mA 33 Ω 50 mA 200 mA measurement ranges 10 to 100 mA 10 Ω 150 mA 0.5 A 0.1 to 1 A 1 Ω 1.5 A 5 A 0.3 to 1.5 A 0.06 Ω 2 A 10 A 1 to 5 A 0.02 Ω 7 A 15 A 3 to 15 A 0.006 Ω 20 A 100 A 13 RM3 Specialty Relays RM3UA2 Voltage Measurement Relays Operating Principles This device is designed to detect when a preset voltage threshold is exceeded, on a.c. or d.c. Monitoring is on overvoltage, within a measurement range of 50 mV to 500 V. Some examples of applications for these relays are: - d.c. motor overspeed control, - battery monitoring, - monitoring of a.c. or d.c. supplies. Operating principles • Apply the appropriate supply voltage (U Supply) to terminals A1 and A2. This supplies power to the electronics inside this device. • The voltage to be monitored is connected to terminals B1 or B2 or B3 (Depending on the voltage to be monitored.) and C. • The output relay terminals (15 - Common, 16 - Normally closed contact, 18 - Normally open contact) is used to signal that the voltage is or is not above the preset voltage threshold setting. • The voltage threshold setting (US1) (refer to the diagram below) is set to the voltage above which it is desired to have RM3UA2 the output relays change state. • The hysteresis needs to be set. The hysteresis is the difference between the voltage threshold setting and the dropout voltage setting (US2) of the output relays. It is expressed as a percentage: h= (US1/US2)/US1. Hysteresis is adjustable between 5 and 30%. RM3 UA2 1 1 Hysteresis setting 5 to 30%. A1 A2 2 Voltage threshold setting (US1). 16 15 18 R The yellow LED labeled with an R indicates that the output 2 R contact has been energized when it is illuminated. U U The green LED labeled with a U (Voltage) Indicates that supply voltage is present to the RM3 relay when illuminated. Functional diagram If the supply voltage is not applied to terminals A1 and A2, the output relays will be in the deenergized state (Contacts • 15-16 will be closed and contacts 15-18 will be open). The voltage to be monitored is connected to terminals B1, B2 or B3 and C. When supply voltage is applied to terminal A1 and A2, the output relay will not change state until the voltage has • exceeded the voltage threshold setting (US1) and the voltage remains above the voltage threshold setting (US1) level for <80 milliseconds. more than the measuring cycle of After the output relay has changed state, it will remain energized unless the voltage falls below the dropout voltage • setting (voltage threshold setting minus the hysteresis) or the supply voltage is lost from terminals A1 and A2 or the measured voltage exceeds the upper limits of the RM3 relay, which results in damage to the RM3 relay. Functional diagram U supply A1-A2 t : measuring cycle US1 US2 Voltage measured 15-18 Relay 15-16 t ≤ 80 ms < t The measurement ranges can be extended beyond 500 V by adding a resistor on model RM3UA213. Simply connect an additional resistor (Rs) in series with Voltage a or c measuring input B3. RM3-UA213 If the value of Rs is in the region of : Rs B3 2 U Rs = Ri ( ) – 1: where Um Ri U > 500 V Ri : internal resistance seen from input B3/C Um : maximum value of the threshold setting range C U : voltage threshold to be measured The relay energization threshold will be towards the middle of the threshold setting potentiometer travel. In general, the power consumed by the resistor does not exceed 0.5 W. Note :The measurement range on Vac supply can be extended by means of a voltage transformer, the secondary of which is connected to the measuring terminals of the corresponding RM3. 14 RM3 Specialty Relays RM3UA2 Voltage Measurement Relays Wiring, Approximate Dimensions, and Setup Information Wiring Connection and voltage values to be measured according to the type of RM3UA2 C RM3UA211 B1-C 50 to 500 mV B2-C 0.3 to 3 V B3-C 0.5 to 5 V RM3UA212 B1-C 1 to 10 V A1 15 B3 A1-A2 Supply voltage B1 B2 B2-C 5 to 50 V B1, B2 Voltages to be measured B3, C (see table to the right) B3-C 10 to 100 V 15-18 Form C contact of output RM3UA213 B2-C 30 to 300 V 15-16 relay C B3-C 50 to 500 V 18 16 A2 Approximate dimensions Inches Dimensions MM 3.94 / 100 .885/22.5 Setup information • Example of overvoltage to be measured: • Product selected is a RM3UA213FG7 from page 16. - Overvoltage threshold to be measured 460 V - Voltage measurement range 30 to 500 V - Reset voltage threshold 410 V - Connection of voltage to be measured B3-C (50 to - Supply voltage 120 V ac 50/60 Hz 500 V) • Measuring principle : - Set the voltage threshold setting potentiometer 2 to 46 RM3 UA2 1 (46 x 10 = 460). A1 A2 - Set the hysteresis 1 to 10.8 % 16 15 18 (460-410) / 460 = .108 = 10.8% 2 R U 15 A1 B1 B2 A2 B3 16 18 15 3.05 / 77.5 RM3 Specialty Relays RM3UA2 Voltage Measurement Relays Ordering Information Voltage to be measured Control Circuit Catalog Weight depending on connection Voltage Number Vac or Vdc 50/60 Hz lb./ (kg) 50 to 500 mV 24 RM3UA211B7 0.43/(0.195) 0.3 to 3 V 42 to 48 RM3UA211DE7 0.43/(0.195) 0.5 to 5 V 110 to 130 RM3UA211FG7 0.43/(0.195) 220 to 240 RM3UA211MU7 0.43/(0.195) 1 to 10 V 24 RM3UA212B7 0.43/(0.195) 5 to 50 V 42 to 48 RM3UA212DE7 0.43/(0.195) 10 to 100 V 110 to 130 RM3UA212FG7 0.43/(0.195) 220 to 240 RM3UA212MU7 0.43/(0.195) 30 to 300 V 24 RM3UA213B7 0.43/(0.195) 50 to 500 V 42 to 48 RM3UA213DE7 0.43/(0.195) RM3UA2 110 to 130 RM3UA213FG7 0.43/(0.195) 220 to 240 RM3UA213MU7 0.43/(0.195) Accessories (to be ordered separately) Description Catalog Weight lb. / (kg) Sealing cover LA9RE02 0.01/(0.003) Replacement Marking Tab LA9D92 0.01/(0.001) LA9RE02 16 RM3 Specialty Relays RM3UA2 Voltage Measurement Relays Application Data Control circuit characteristics Rated supply voltage (Un) Vac 50-60 Hz V 24 42 to 48 110 to 130 220 to 240 Average consumption at Un Vac VA 2.1 2.9 2.4 3.2 Output relay and operating characteristics Number of C/O (Form C) contacts 1 Output relay state Energized when voltage threshold exceeded Rated operational voltage IEC V 250 (switching) UL V 300 Conventional thermal current IEC A 4 UL A 5 Rated breaking capacity AC-15, 220 V A 1.5 NEMA B300 Time delay None Switching threshold drift Depending on ≤ 0.06 % per degree centigrade permissible ambient temperature Within the supply ≤ 0.5 % voltage range (85% to 110% of Un) Hysteresis Adjustable 5 to 30 % of the voltage threshold setting Measuring cycle ms ≤ 80 Operating status indication Green LED on Supply Voltage (Un) is present to the relay. Yellow LED on Relay energized (voltage threshold exceeded) Measuring input characteristics Internal input resistance Measurement range Internal input Permissible continuous Permissible overload and permissible overload Vac 50-60 Hz and Vdc resistance Ri overload for t ≤ 1 s depending on the voltage 50 to 500 mV 7.7 kΩ 20 V 25 V measurement ranges 0.3 to 3 V 46.5 kΩ 60 V 80 V 0.5 to 5 V 77.5 kΩ 80 V 100 V 1 to 10 V 19 kΩ 90 V 100 V 5 to 50 V 95 kΩ 150 V 200 V 10 to 100 V 190 kΩ 300 V 400 V 30 to 300 V 570 kΩ 400 V 500 V 50 to 500 V 950 kΩ 550 V 550 V 17 RM3 Specialty Relays RM3UA1 Voltage Measurement Relays Operating Principles This device is designed to detect when a preset voltage threshold is exceeded, on a.c. or d.c. supply. Monitoring is on overvoltage or undervoltage, within a measurement range of 50 mV to 500 V. Applications : - d.c. motor overspeed control, - battery monitoring, - monitoring of a.c. or d.c. supplies. Operating principles • Apply the appropriate supply voltage (U Supply) to terminals A1 and A2. This supplies power to the electronics inside this device. • The voltage to be monitored is connected to terminals B1 or B2 or B3 (Depending on the voltage to be monitored.) and C. • The output relay terminals (15 & 25 - Commons, 16 & 26 - Normally closed contacts, 18 & 28 - Normally open contacts) are used to signal that the voltage is or is not above the preset voltage threshold setting. • Relay set for overvoltage detection (OV) : If the voltage is greater than the threshold setting US1, the output relay is energized with or without time delay. When RM3UA1 the voltage returns to a value US2 below the threshold, depending on the hysteresis setting, the relay is instantaneously de-energized. • Relay set for undervoltage detection (UV) : If the voltage is less than the threshold setting US1, the output relay is energized with or without time delay. When the voltage returns to a value US2 above the threshold, depending on the hysteresis setting, the relay is de- energized. • The hysteresis needs to be set . The hysteresis is the difference between the voltage threshold setting and the dropout voltage setting (US2) of the output relays. It is expressed as a percentage: h= (US1/US2)/US1. Hysteresis is adjustable between 5 and 30 %. • A measuring cycle lasts only 80 ms, which allows rapid detection of changes in voltage. 1 Time delay range selector switch (0.05 to 1 s or 1.5 to 30 s). 2 Time delay setting. RM3 UA1 1 A1 A2 3 Hysteresis setting 5 to 30 % (1). 16 15 18 4 Voltage threshold setting. 3 1s 26 5 Undervoltage (UV) or overvoltage (OV) setting selector. 25 28 4 R The yellow LED labeled with an R indicates that the output contacts have 2 been energized when it is illuminated. UV R U The green LED labeled with a U (Voltage) indicates that the supply voltage is 5 U present to the RM3 relay when illuminated. (1) Value of the voltage differential between energization and de-energization of the output relay (% of the voltage threshold to be measured). Functional diagram Function "OV" Function "UV" U supply A1-A2 U supply A1-A2 US2 US1 US1 US2 Voltage measured Voltage measured 15-18 15-18 15-16 15-16 Relay Relay 25-28 25-28 25-26 25-26 t : time delay t < t t < t The measurement ranges can be extended beyond 500 V by adding a resistor on models RM3UA103 and RM3UA113. Voltage a or c Simply connect an additional resistor (Rs) in series with the measuring input B3 RM3-UA or C. If the value of Rs is in the region of : Rs C 103 ou UA 113 2 U Ri U > 500 V Rs = Ri ( ) - 1 : where Ri : internal resistance seen from input B3/C Um B3 Um : maximum value of threshold setting range U : voltage threshold to be measured The relay energization threshold will be towards the middle of the threshold setting potentiometer travel. In general, the power consumed by the resistor does not exceed 0.5 W Note :The measurement range on Vac supply can be extended by means of a voltage transformer, the secondary of which is connected to the measuring terminals of the corresponding RM3. 18 RM3 Specialty Relays RM3UA1 Voltage Measurement Relays Wiring, Approximate Dimensions, and Setup Information Wiring Connection and voltage values to be measured according to C the type of RM3UA1 RM3UA1•1 B1-C 50 to 500 mV A1-A2 Supply voltage B2-C 0.3 to 3 V B3-C 0.5 to 5 V B1, B2, Voltages to be measured A1 15 25 B1 B2 B3 B3, C (see table to the right) RM3UA1•2 B1-C 1 to 10 V B2-C 5 to 50 V st 15-18 1 C/O (Form C) contact of output B3-C 10 to 100 V 15-16 relay RM3UA1•3 B2-C 30 to 300 V nd 25-28 2 C/O (Form C) contact of output 16 18 28 26 C A2 B3-C 50 to 500 V 25-26 relay Approximate dimensions Inches Dimensions MM 3.94 / 100 1.77 / 45 Setup information • Example of undervoltage to be measured : • Using page 20, an RM3UA112FG7 would be selected because it will work on 120 Vac and has a range of 1 to 100 V and has an adjustable time delay of - Undervoltage threshold to be measured 24 Vdc from 0.05 to 30 seconds. - Output relay time delay 20 seconds - Reset voltage threshold 27 Vdc • To set up the relay: - Supply voltage120 Vac 60 Hz - Place the function selector 5 on UV. - Place the timing range selector 1 on 30 s. - Set the potentiometer 2 to 20. RM3 UA1 - Set the voltage threshold setting potentiometer 4 to 24 (24 x 1 = 24). 1 A1 A2 Voltage to be measured would be connected to terminals B2 and C. 16 - Set the hysteresis 3 to 12.5 % (27 - 24) / 27 = .125 = 12.5% 15 18 3 1s 26 25 28 4 2 UV R 5 U 19 A1 B1 B2 A2 B3 16 18 15 26 28 25 3.05 / 77.5 RM3 Specialty Relays RM3UA1 Voltage Measurement Relays Ordering Information Time delay Voltage to be measured Supply Voltage Catalog Weight depending on connection (Vac 50/60 Hz.) Number lb./(kg) Adjustable 50 to 500 mV 24 to 240 Vac or Vdc RM3UA111MW .66/(0.300) 0.05 to 30 0.3 to 3 V 110 to 130 Vac RM3UA111FG7 .66/(0.300) 0.5 to 5 V 220 to 240 Vac RM3UA111MU7 .66/(0.330) 380 to 415 Vac RM3UA111QN7 .66/(0.300) 1 to 10 V 24 to 240 Vac or Vdc RM3UA112MW .66/(0.300) 5 to 50 V 110 to 130 Vac RM3UA112FG7 .66/(0.300) 10 to 100 V 220 to 240 Vac RM3UA112MU7 .66/(0.300) 380 to 415 Vac RM3UA112QN7 .66/(0.300) 30 to 300 V 24 to 240 Vac or Vdc RM3UA113MW .66/(0.300) 50 to 500 V 110 to 130 Vac RM3UA113FG7 .66/(0.300) 220 to 240 Vac RM3UA113MU7 .66/(0.300) RM3UA1 380 to 415 Vac RM3UA113QN7 .66/(0.300) None 50 to 500 mV 24 to 240 Vac or Vdc RM3UA101MW .66/(0.300) 0.3 to 3 V 110 to 130 Vac RM3UA101FG7 .66/(0.300) 0.5 to 5 V 220 to 240 Vac RM3UA101MU7 .66/(0.300) 380 to 415 Vac RM3UA101QN7 .66/(0.300) 1 to 10 V 24 to 240 Vac or Vdc RM3UA102MW .66/(0.300) 5 to 50 V 110 to 130 Vac RM3UA102FG7 .66/(0.300) 10 to 100 V 220 to 240 Vac RM3UA102MU7 .66/(0.300) 380 to 415 Vac RM3UA102QN7 .66/(0.300) 30 to 300 V 24 to 240 Vac or Vdc RM3UA103MW .66/(0.300) 50 to 500 V 110 to 130 Vac RM3UA103FG7 .66/(0.300) 220 to 240 Vac RM3UA103MU7 .66/(0.300) 380 to 415 Vac RM3UA103QN7 .66/(0.300) Accessories (to be ordered separately) Description Catalog Weight Number lb./(kg) Sealing cover LA9RM301 0.01/(0.005) Replacement Marking Tab LA9D92 0.01/(0.001) LA9RM301 20 RM3 Specialty Relays RM3UA1 Voltage Measurement Relays Application Data Control circuit characteristics Rated supply voltage (Un) Vac 50-60 Hz V 24 to 240 110 to 130 220 to 240 380 to 415 Vdc V 24 to 240 – – – Average consumption at Un Vac VA 2.2 to 6 4.8 3.5 4 Vdc W2––– Output relay and operating characteristics Number of C/O (Form C) contacts 2 Rated operational voltage IEC V 400 (switching) UL V 300 Conventional thermal current IEC A 5 UL A 5 Rated breaking capacity AC-15 230 V-3 A, 400 V-2 A NEMA B300 Time delay on energization RM3UA11 sec. Adjustable from 0.05 to 30 RM3UA10 None Switching threshold drift Depending on < 0.06 % per degree centigrade permissible ambient temperature Within the supply < 0.5 % voltage range (85 to 110% Un) Time delay drift Within the supply < 0.5 % voltage range Depending on < 0.06 % per degree centigrade nominal operating temperature Output relay state Energized when voltage threshold exceeded Operating status indication Green LED on Supply Voltage (Un) is present to the relay. Yellow LED on Relay energized (voltage threshold exceeded) Hysteresis Adjustable 5 to 30 % of the voltage threshold setting Measuring cycle ms < 80 Measuring input characteristics Internal input resistance Measurement range Internal input Permissible continuous Permissible overload and permissible overload Vac 50-60 Hz and Vdc resistance Ri overload for t < 1 sec. depending on the voltage 50 to 500 mV 7.7 Ω 20 V 25 V measurement ranges 0.3 to 3 V 46.5 Ω 60 V 80 V 0.5 to 5 V 77.5 Ω 80 V 100 V 1 to 10 V 19 Ω 90 V 100 V 5 to 50 V 95 Ω 150 V 200 V 10 to 100 V 190 Ω 300 V 400 V 30 to 300 V 570 Ω 400 V 500 V 50 to 500 V 950 Ω 550 V 550 V 21 RM3 Specialty Relays RM3TG2 3-Phase Supply Relays Operating Principles This device monitors the presence and rotational direction of the phases in a 3-phase supply under no-load condition. Applications: • Connection of moving equipment : - site equipment (cranes, pumps, conveyors, etc.), - agricultural equipment, - refrigerated trucks. • Protection of persons and equipment against the consequences of reverse running: - lifting, handling, elevators, escalators, etc. • Control of sensitive 3-phase supplies. Operating principle The voltage of the supply to be monitored, connected to terminals L1, L2, L3 of the relay, also provides its power supply. In normal operation, the output relay is energized, the yellow LED is on. If a fault occurs - reversal in rotational direction of phases, failure of one or more phases - the relay is de-energized (or cannot energize at switch-on) and the yellow LED RM3TG2 goes out. This relay is specifically designed for control of supplies under no-load conditions. In the case of a supply under load, a return voltage can be registered by the RM3 in spite of a phase failure, thereby preventing detection of the true fault (phase failure detection threshold U < 60 V). For control of supplies under load, select an RM3TR or TAR1. RM3 TG2 R The yellow LED labeled with an R indicates that the output L1 L3 contacts have been energized when it is illuminated. L2 16 15 18 26 25 28 R Functional diagram L1, L2, L3 L1, L3, L2 L1, L2, L3 L2, L3 L1 L1, L2, L3 15-18 15-16 Relay 25-28 25-26 22 RM3 Specialty Relays RM3TG2 3-Phase Supply Relays Wiring and Approximate Dimensions Wiring L1, L2, L3 Supply voltage Connection and voltage values to be controlled 15 L3 L1, L2, L3 3-phase voltages to be controlled RM3TG2 L1-L2-L3 220 to 500 V (50-60 Hz) L1 L1 L2 L2 25 (see table to the right) st 15-18 1 C/O (Form C) contact of output relay 15-16 28 26 nd 25-28 2 C/O (Form C) contact of output relay 18 16 25-26 Approximate dimensions Inches Dimensions MM .885/22.5 3.94 / 100 For a voltage equal to or greater than 415 V, a minimum distance of 10 mm must be left between relays if several are mounted side by side. 23 L1 L2 L3 16 18 15 26 28 25 3.05 / 77.5 RM3 Specialty Relays RM3TG2 3 Phase Supply Relays Ordering Information Time delay Control and Catalog Weight supply voltage Number Vac 50-60 Hz Seconds Volts lb./(kg) None 220 to 500 RM3TG201MS7 0.36/(0.165) RM3TG2 Accessories (to be ordered separately) Description Catalog Weight Number lb./(kg) Sealing cover LA9RE02 0.01/(0.003) Replacement Marking Tab LA9D92 0.01/(0.001) LA9RE02 24 RM3 Specialty Relays RM3TG2 3-Phase Supply Relay Application Data Control circuit characteristics Rated supply voltage (Un) Vac 50-60 Hz V 220 to 500 Average consumption at Un Phases L1, L2 Vac VA 2.2 to 12.5 Output relay and operating characteristics Number of C/O (Form C) contacts 2 Output relay state Energized during fault free operation De-energized or unable to energize on detection of rotational direction fault or phase failure Rated operational voltage IEC V 250 (switching) UL V 300 Conventional thermal current IEC A 4 UL A 5 Rated breaking capacity AC-15, 220 V A 1.5 NEMA B300 Time delay None Operating status indication Yellow LED on Relay energized 25 RM3 Specialty Relays RM3TR1 3-Phase Supply Relays Operating Principles This multifunction device is designed to monitor the presence and rotational direction of the phases in a three-phase supply, as well as overvoltage (U > Un) or undervoltage (U < Un). Applications • Connection of moving equipment: - site equipment (cranes, pumps, conveyors, etc.), - agricultural equipment, - refrigerated trucks. • Protection of persons and equipment against the consequences of reverse running: - lifting, handling, elevators, escalators, etc. Operating principles The control circuit supply voltage (Usupply) is applied to terminals A1-A2. Monitoring of the 3-phase supply (Un) is performed on terminals L1, L2, L3. In normal operation, the output relay is energized, the yellow LED is on. RM3TR110 The output relay is de-energized and the yellow LED goes out if any of the following faults are detected: • Overvoltage or undervoltage RM3TR111, TR113, TR115 If the voltage goes outside the range of Un, the output relay is de-energized: - overvoltage: the red LED > U illuminates, TR112, TR114 - undervoltage: the red LED < U illuminates. When the supply returns to its rated value, the relay is reenergized according to the hysteresis value (5 %) and the corresponding indicator goes out. A selector switch allows selection of an adjustable 0.1 to 10 second time delay. With function ,this delay will allow the relay to ignore transient “over” and “under” voltages that might occur. With function , all transients above and below are taken into account and re-energization of the relay is delayed. • Phase failure or incorrect rotational direction of phases The output relay is de-energized without a time delay in the event of a phase failure or incorrect rotational direction of phases, the red LED “P” illuminates. The output relay is energized and the fault indicator goes out as soon as the 3-phase supply (Un) returns to normal, (function ) or after a preset time delay, (function ). 1 Time delay function selector: Fault detection delayed. RM3 TR1 Fault detection extended. 3 A1 A2 2 Potentiometer for setting time delay, in seconds. 16 15 18 3 Potentiometer for setting overvoltage. 1 26 4 Potentiometer for setting undervoltage. 25 28 R Yellow LED : indicates output relay has been energized 2 when illuminated. U Green LED : indicates that supply voltage (Usupply) is U 4 present to the RM3 relay when illuminated. R U >U Red LED : overvoltage fault exists. U P U Red LED on An overvoltage situation exists. < U Red LED on An undervoltage situation exists. P Red LED on Incorrect rotational direction of phases or phase failure exists. Control input characteristics Nominal voltages to be monitored Vac 50 Hz V 220, 400, 500 Vac 50-60 Hz V 220, 380 to 420, 430 to 500 29 RM3 Specialty Relays RM3TA2 3-Phase Supply Relay Operating Principles This device detects: • A phase imbalance (asymmetry fault) within an adjustable threshold from 5 to 15 % (reduction or increase in voltage of one phase in relation to the other two). • Failure of one or more phases. • A phase reversal (Rotational direction of phases fault). Applications: • Connection of moving equipment: - site equipment (cranes, pumps, conveyors, etc.), - agricultural equipment, - refrigerated trucks. • Protection of motors against single-phase operation. • Control of sensitive 3-phase supplies. Operating principle RM3TA2 The supply voltage to be monitored is connected to terminals L1, L2, L3 of the relay, it also provides the power for the relay to operate. In normal operation, the output relay is energized and the yellow LED is on. When a phase imbalance (asymmetry fault), phase failure or phase reversal (rotational direction fault) is detected, the output relay de-energizes after a fixed time delay of 0.5 seconds (or cannot energize at start up), and the yellow LED goes out. A fixed hysteresis (1) of 20 % is built-into the relay. 1 Phase imbalance (Asymmetry) threshold setting RM3 TA2 potentiometer, from 5 to 15 %. L1 L3 L2 R Yellow LED is illuminated when no fault condition exists 16 15 18 and the output relay is energized. 1 R Functional diagram Asymmetry L1 L1, L2, L3 L1, L3, L2 L1, L2 L1, L2 L2 Un L3 L3 Asymmetry L3 Δ L1/L3 > U asymmetry L1, L2, L3 15-18 Relay 15-16 t = 0.5 s t: time delay (1) Hysteresis is the voltage differential (dissymmetry) between energization and de-energization of the output relay (% in relation to the preset asymmetry value). Example: Phase imbalance is set at 10 %, 480 Vac supply - relay de-energization threshold: 480 - 10 % = 432 V, - relay re-energization threshold: 432 V + (20 % x 10 %) of 432 V = 440.6 V. 30 RM3 Specialty Relays RM3TA2 3-Phase Supply Relay Wiring and Approximate Dimensions Wiring L1, L2, L3 Supply voltage and voltages to be Connection and voltage values to be controlled according to monitored (see table to the right) the type of RM3TA2 15 L3 st 15-18 1 C/O (Form C) output relay L1 L2 RM3TA210 L1-L2-L3 220 to 240 V - 60 Hz 15-16 RM3TA211 L1-L2-L3 220 to 240 V - 50 Hz RM3TA212 L1-L2-L3 380 to 415 V - 60 Hz RM3TA213 L1-L2-L3 380 to 415 V - 50 Hz 18 16 Approximate dimensions Inches Dimensions MM 3.94 / 100 .885/22.5 31 L1 L2 L3 16 18 15 3.05 / 77.5 RM3 Specialty Relays RM3TA2 3-Phase Supply Relays Ordering Information Time delay Supply voltage and Catalog Weight on de-energization voltages to be monitored Number Seconds V lb./(kg) Fixed 0.5 220 to 240 - 60 Hz RM3TA210M6 0.42/(0.190) 220 to 240 - 50 Hz RM3TA211M5 0.42/(0.190) 380 to 415 - 60 Hz RM3TA212V6 0.42/(0.190) 380 to 415 - 50 Hz RM3TA213V5 0.42/(0.190) RM3TA2 Accessories (to be ordered separately) Description Catalog Weight Number lb./(kg) Sealing cover (22.5 mm width) LA9RE02 0.01/(0.003) Replacement marking tab LA9D92 0.01/(0.001) LA9RE02 32 RM3 Specialty Relays RM3TA2 3-Phase Supply Relay Application Data Control circuit characteristics Rated supply voltage (Un) Vac 50/60 Hz V 220 to 240 380 to 415 Average consumption at Un Phases L2, L3 Vac VA 1.3 1.4 Rated supply and monitoring + or - 15 % + or - 15% voltage tolerance Output relay and operating characteristics Number of C/O (Form C) contacts 1 Output relay state De-energized on detection of phase imbalance, phase failure or phase reversal. Rated operational voltage IEC V 250 (switching) UL V 300 Conventional thermal current IEC A 4 UL A 5 Rated breaking capacity AC-15, 220 V A 1.5 NEMA B300 Time delay on de-energization Fixed Sec. 0.5 Switching threshold drift Depending on < 0.06 % per degree centigrade permissible ambient temperature Within the supply < 0.5% voltage range (85 to 110% of Un) Hysteresis Fixed Approximately 20% in relation to phase imbalance threshold. Phase imbalance Adjustable 5 to 15% Operating status indication Yellow LED on Relay is energized 33 RM3 Specialty Relays RM3TAR1 3-Phase Supply Relay Operating Principles This device detects: • A phase imbalance (asymmetry fault) within an adjustable threshold from 5 to 15 % (Reduction or increase in voltage of one phase in relation to the other two.). • Failure of one or more phases. • A Phase reversal (Rotational direction of phases fault). Applications: • Connection of moving equipment: - site equipment (cranes, pumps, conveyors, etc.), - agricultural equipment, - refrigerated trucks. • Protection of persons and equipment against the consequences of reverse running: lifting, handling, elevators, escalators, etc. • Control of sensitive 3-phase supplies. RM3TAR1 Operating principle The supply voltage is connected to terminals A1 and A2. The 3-phase voltage to be monitored is connected to L1, L2, and L3 of the relay. In normal operation, the output relay is energized, the yellow and green LEDs are on. If a phase reversal (rotational direction) or phase failure fault is detected, the relay is de-energized (or cannot energize at start up), the yellow LED goes out, the red LED (P) illuminates. If a phase imbalance (asymmetry fault) is detected, the output relay de-energizes after a preset time delay between 0.1 and 10 seconds, the yellow LED goes out and the red LED (A) illuminates. A fixed hysteresis (1) of 20 % is built into the relay. 1 Phase imbalance (Asymmetry) threshold setting potentiometer, from 5 to 15 %. RM3 TAR1 2 Time delay setting potentiometer, from 0.1 to 10 s. R The yellow LED labeled with an R indicates that 1 A1 A2 the output contacts have been energized when it 16 15 18 is illuminated. 2 26 U The green LED labeled with a U (Supply voltage) 25 28 indicates that supply voltage is present to the RM3 relay when illuminated. R A A Red LED: A phase imbalance (dissymmetry) U P exists. P Red LED: A phase failure (2 or 3) exists. P and A Red LEDs: A phase reversal (Incorrect rotational direction of phases) exists Functional diagram U supply A1-A2 Asymmetry L1 L1, L2, L3 L1, L3, L2 L1, L2 L1, L2 L2 Un L3 L3 Asymmetry L3 Δ L1/L3 > U asymmetry L1, L2, L3 15-18 15-16 Relay 25-28 25-26 t t: time delay (1) Hysteresis is the voltage differential (dissymmetry) between energization and de-energization of the output relay. (% in relation to the preset phase imbalance (asymmetry) value). Example: asymmetry set at 10 %, 480 Vac supply - relay de-energization threshold: 480 - 10 % = 432 V, - relay re-energization threshold: 432 V + (20 % x 10 %) of 432 V = 440.6 V. 34 RM3 Specialty Relays RM3TAR1 3-Phase Supply Relay Wiring and Approximate Dimensions Wiring Connection and voltage values to be controlled according to the type of RM3TAR1 RM3TAR110 L1-L2-L3 220 to 240 V - 60 Hz A1-A2 Supply voltage A1 15 25 L1 L2 L3 RM3TAR111 L1-L2-L3 220 to 240 V - 50 Hz L1, L2, L3 3-phase voltages to be monitored (See table to the right.) RM3TAR112 L1-L2-L3 380 to 415 V - 60 Hz st 15-18 1 C/O (Form C) contact of output relay RM3TAR113 L1-L2-L3 380 to 415 V - 50 Hz 15-16 RM3TAR114 L1-L2-L3 480 to 500 V - 60 Hz nd 25-28 2 C/O (Form C) contact of output relay 16 18 28 26 A2 RM3TAR115 L1-L2-L3 480 to 500 V - 50 Hz 25-26 Approximate dimensions Inches Dimensions MM 3.94 / 100 1.77 / 45 35 A1 L1 L2 A2 L3 16 18 15 26 28 25 3.05 / 77.5 RM3 Specialty Relays RM3TAR1 3-Phase Supply Relays Ordering Information Adjustable Voltage to be Supply Voltage Catalog Weight time delay monitored (Vac 50/60 Hz.) Number Sec. V V lb./(kg) 0.1 to 10 220 to 240 - 60 Hz 110 to 130 RM3TAR110FG7 0.69/(0.315) 220 to 240 RM3TAR110MU7 0.69/(0.315) 380 to 415 - 60 Hz 110 to 130 RM3TAR112FG7 0.69/(0.315) 220 to 240 RM3TAR112MU7 0.69/(0.315) 380 to 415 RM3TAR112QN7 0.69/(0.315) 480 to 500 - 60 Hz 110 to 130 RM3TAR114FG7 0.69/(0.315) 220 to 240 RM3TAR114MU7 0.69/(0.315) 380 to 415 RM3TAR114QN7 0.69/(0.315) 480 to 500 RM3TAR114TS7 0.69/(0.315) 220 to 240 - 50 Hz 110 to 130 RM3TAR111FG7 0.69/(0.315) RM3TAR1 220 to 240 RM3TAR111MU7 0.69/(0.315) 380 to 415 RM3TAR111QN7 0.69/(0.315) 380 to 415 - 50 Hz 110 to 130 RM3TAR113FG7 0.69/(0.315) 220 to 240 RM3TAR113MU7 0.69/(0.315) 380 to 415 RM3TAR113QN7 0.69/(0.315) 480 to 500 - 50 Hz 110 to 130 RM3TAR115FG7 0.69/(0.315) 220 to 240 RM3TAR115MU7 0.69/(0.315) 380 to 415 RM3TAR115QN7 0.69/(0.315) Accessories (to be ordered separately) Description Catalog Weight Number lb./(kg) Sealing cover (45mm width) LA9RM301 0.01/(0.005) Replacement marking tab LA9D92 0.01/(0.001) LA9RM301 36 RM3 Specialty Relays RM3TAR1 3-Phase Supply Relay Application Data Control circuit characteristics Rated supply voltage (Un) Vac 50-60 Hz V 110 to 130 220 to 240 380 to 415 480 to 500 Except for RM3TAR114 RM3TAR110 ONLY Average consumption at Un Vac VA 2.7 2.8 3 3 Output relay and operating characteristics Number of C/O (Form C) contacts 2 Output relay state De-energizes on detection of a phase imbalance (asymmetry fault), a phase failure or a phase reversal (rotational direction of phases fault). Rated operational voltage IEC V 400 (switching) UL V 300 Conventional thermal current IEC A 5 UL A 5 Rated breaking capacity AC-15 230 V-3 A, 400 V-2 A NEMA B300 Time delay on de-energization Adjustable Sec. 0.1 to 10 Switching threshold drift Depending on < 0.06% per degree centigrade permissible ambient temperature Within the supply < 0.5% voltage range (85 to 110% of Un) Time delay drift Within the supply < 0.5% voltage range Depending on < 0.06% per degree centigrade nominal operating temperature Hysteresis Fixed Approximately 20% in relation to phase imbalance (asymmetry) threshold Phase asymmetry control Adjustable 5 to 15% Measuring cycle ms ≤ 100 Operating status indication U Green LED on Supply voltage (Usupply) is present to the relay. R Yellow LED on Relay is energized A Red LED on Phase imbalance (asymmetry) fault exists. P Red LED on Phase failure (2 or 3) exists. P and A LEDs on Phase reversal (Incorrect rotational direction of phases or phase failure.) Measuring input characteristics Monitoring voltage + or - 15 % tolerance 37 RM3 Specialty Relays RM3LG2 Liquid Level Control Relay Operating Principles This device monitors the levels of conductive liquids. Do not use with flammable liquids. It controls the actuation of pumps or valves to regulate the levels and is also suitable for protecting submersible pumps against running empty, or protecting tanks from “overflow”. It can also be used to control dosing of liquids in mixing processes. • Some examples of liquids in which the RM3LG2 relay can be used: - spring, town, industrial and sea water - metallic, acid or basic salt solutions - liquid fertilizers - non concentrated alcohol (< 40 %) - liquids in the food processing industry: milk, beer, coffee, etc. • Some examples of liquids in which the RM3LG2 relay CAN NOT be used: - chemically pure water - fuels, liquid gasses (flammable) - oil, concentrated alcohol (> 40 %) - ethylene, glycol, paraffin, varnish and paints RM3LG2 Presentation 1 Response sensitivity potentiometer (in kW). R The yellow LED labeled with an R indicates that the RM3 LG2 output relays have been energized when it is illuminated. 1 A1 A2 U The green LED labeled with a U (Supply voltage) 16 indicates that supply voltage is present to the RM3 relay 15 18 when illuminated. R U Operating principle The operating principle is based on a change in the resistance measured between immersed or non immersed electrodes. The electrodes may be replaced by other sensors or probes which transmit values representing variations in resistance (Refer to page 39, “Setting-up”). • 3 electrodes (1) B1 B2 B3 B1 B2 B3 B1 B2 B3 B1 B2 B3 B1 B2 B3 B1 B2 B3 B2 high level B2 low level B1 ground electrode (reference) 15-18 Relay 15-16 U supply A1-A2 Note: If a metallic tank is used, the ground electrode (B1) can be eliminated by connecting the cable directly to one of the tank’s metallic surfaces. (1) This product can be used with only 2 electrodes. In this case, electrode B2 performs both the high level and low level functions. The absence of a time delay can cause oscillation of the output relay (wave effect). 38 RM3 Specialty Relays RM3LG2 Liquid Level Control Relay Wiring, Approximate Dimensions, and Setup Information Wiring A1-A2 Supply voltage A1 15 B3 Electrodes and levels controlled B1 B2 B1 Ground electrode B1, B2, B3 Electrodes (see table to the right) B2 Max. level B3 Min. level 15-18 C/O (Form C) contact 18 16 A2 15-16 of output relay Approximate dimensions Inches Dimensions MM 3.94 / 100 .885/22.5 Setup information Set the potentiometer to the minimum value. Connect the electrodes as shown below. RM3 LG2 Apply power to terminals A1 and A2. A1 A2 When all the electrodes are simultaneously immersed in the liquid to be monitored, slowly turn the potentiometer towards 16 the maximum value (100 W) until the relay is energized. Exceed the tripping threshold of the relay by 10 kW to 15 18 compensate for variations in the supply voltage. (The relay may already be energized before turning the potentiometer). If the relay will not energize, a more sensitive device must be used (greater ohmic value): see RM3LA1. Then check that the relay de-energizes correctly as soon as electrodes EH and EB are out of the liquid (see examples R below). If the relay does not de-energize, select a less sensitive device (see RM3LA1). U The electrode connection point must be protected against corrosion, by sticking or sealing. In areas where thunderstorms are likely to occur, measures must also be taken to protect the electrode lines. Probe LA9RM201 This probe is of the “suspended” type. It is coaxial; i.e. in addition to the normal (central) electrode, the stainless steel skirt 2-conductor cable in can also act as ground (reference) electrode, which means that there is no need to install a separate reference probe. In cylindrical sheath this way, for controlling one level, only one probe is required instead of 2; for controlling 2 levels, only 2 probes are (max. Ø 6.3 mm) required instead of 3. The connecting cable must be of the “2-conductor” type with common cylindrical PVC sheath, having a maximum Level electrode diameter of 6.3 mm. The skirt also acts as a “calming chamber”, so avoiding inaccuracy due to an agitated surface of the liquid (waves). Maximum operating temperature: 212 °F (100 °C). Reference Connection examples electrode (skirt) Control by electrodes Control by probes RM3-LG2 High B2 B2 level A1 15 B1 B2 B3 B3 B1 EH B1 Low level EH EH EB M M EB M 16 18 A2 2 levels 1 level EH = High level electrode EB = Low level electrode M = Reference electrode (common) 39 A1 B1 B2 A2 B3 16 18 15 3.05 / 77.5 supply voltage B1 B2 B3 16 18 15 RM3 Specialty Relays RM3LG2 Liquid Level Control Relay Ordering Information Liquid level relay Fixed Sensitivity Control Circuit Catalog Weight time delay Scale Voltage 50/60 Hz Number ms Ω V lb./(kg) 250 5 to 100 24 RM3LG201B7 0.43/(0.195) 110 to 130 RM3LG201FG7 0.43/(0.195) 220 to 240 RM3LG201MU7 0.43/(0.195) 380 to 415 RM3LG201QN7 0.43/(0.195) RM3LG2 Liquid level control probe Type of installation Maximum operating Catalog Weight temperature Number lb./(kg) Suspended by cable 212°F (100 °C) LA9RM201 0.22/(0.100) LA9RM201 Accessories (to be ordered separately) Description Catalog Weight Number lb./(kg) Sealing cover (22.5mm width) LA9RE02 0.01/(0.003) Replacement Marking Tab LA9D92 0.01/(0.001) LA9RE02 40 RM3 Specialty Relays RM3LG2 Liquid Level Control Relays Application Data Control circuit characteristics Rated supply voltage (Un) Vac 50-60 Hz V 24 110 to 130 220 to 240 380 to 415 Average consumption at Un Vac VA 1.9 2.6 2.4 2.9 Output relay and operating characteristics Number of C/O (Form C) contacts 1 Output relay state Energized when the high level electrode is immersed and de-energized when the low level electrode is no longer immersed Rated operational voltage IEC V 250 (switching) UL V 300 Conventional thermal current IEC A 4 UL A 5 Rated breaking capacity AC-15, 220 V A 1.5 NEMA B300 Time delay Fixed ms 250 Operating status indication U Green LED on Supply Voltage (U supply) is present to the relay. R Yellow LED on Output relay is energized. Electrode circuit characteristics (1) Sensitivity scale Adjustable Ω 5 to 100 Maximum electrode voltage Vac V 30 Maximum electrode current mA 1 Maximum cable capacity nF 10 Maximum cable length m 100 (1) The electrodes may also be built into the probes. The probes are designed to be either fixed to a tank, by means of a bracket with a seal (closed tanks), or suspended by their own electrical connecting cable (bore holes, etc.). Refer to “Setting-up” (Probe LA9RM201) section on page 39. 41 RM3 Specialty Relays RM3LA1 Liquid Level Control Relay Operating Principles This device monitors the levels of conductive liquids. Do not use with flammable liquids. It controls the actuation of pumps or valves to regulate the levels. It is also suitable for protecting submersible pumps against running empty, or protecting tanks from “overflow”. It can also be used to control dosing of liquids in mixing processes. • Some examples of liquids in which the RM3LA1 can be used with: - spring, town, industrial and sea water - metallic, acid or basic salt solutions - liquid fertilizers - non concentrated alcohol (< 40 %) - liquids in the food processing industry : milk, beer, coffee, etc. • Some examples of liquids in which the RM3LA1 CAN NOT be used with: - chemically pure water - fuels, liquid gasses (flammable) - oil, concentrated alcohol (> 40 %) - ethylene, glycol, paraffin, varnish and paints 1 Selector for time delay on energization or on RM3LA1 de-energization of the relay. RM3 LA1 1 2 0.1 to 10 second time delay potentiometer. A1 A2 16 3 Sensitivity range adjustment (5k, 50k or 500k). 15 18 3 26 4 Fine sensitivity adjustment 25 28 5k range (potentiometer setting times 0.1). 4 50k range (potentiometer setting times 1). 500k range (potentiometer setting times 10). 2 R U The green LED labeled with a U (Supply voltage) U indicates that the supply voltage is present to the RM3 relay when illuminated. R The yellow LED labeled with an R indicates that the output relay is energized when it is illuminated. Operating principle The operating principle is based on a change in the resistance measured between immersed or non immersed electrodes. The electrodes may be replaced by other sensors or probes which transmit values representing variations in resistance (Refer to page 43, “Setting-up”). Time delay on filling (1) Time delay on emptying (1) • 2 electrodes B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 Max. level Min. level 15-18 15-16 2 Form C relay 25-28 25-26 U supply A1-A2 t t • 3 electrodes B1 B2 B3 B1 B2 B3 B1 B2 B1 B2 B1 B2 B3 B1 B2 B3 B3 B3 Max. level Min. level Ground electrode (reference) 15-18 15-16 2 Form C relay (1) 25-28 25-26 U supply A1-A2 t t Note : If a metallic tank is used, the ground electrode (B1) can be eliminated by connecting the cable directly to one of the tank’s metallic surfaces. (1) Level exceeded, see page 43 “Setting-up”. 42 Δ t Δ t Δ t Δ t RM3 Specialty Relays RM3LA1 Liquid Level Control Relay Wiring, Approximate Dimensions, and Setup Information Wiring A1-A2 Supply voltage Electrodes and levels controlled B1, B2, B3 Electrodes B1 Ground electrode A1 15 25 B1 B2 B3 (see table to the right) B2 Max. level st 15-18 1 C/O (Form C) contact B3 Min. level 15-16 of output relay nd 25-28 2 C/O (Form C) contact 16 18 28 26 A2 25-26 of output relay Approximate dimensions Inches Dimensions MM 3.94 / 100 1.77 / 45 Setup information Set potentiometers 4 and 2 to the minimum value and set switch 3 to 5 k. Connect the electrodes as shown below. Apply power to terminals A1 and A2. RM3 LA1 1 A1 A2 When all the electrodes are simultaneously immersed in the liquid to be monitored, slowly turn the sensitivity 16 potentiometer 4 towards the maximum value (50) until the relay is energized. (The relay may energize before turning the 15 18 3 potentiometer. If it does you are finished with this step.). If the relay will not energize, set potentiometer 4 back to its 26 25 28 minimum setting and turn switch 3 to 50k and repeat the above procedure. If the relay still doesn’t energize, set 4 potentiometer 4 back to its minimum setting again and turn switch 3 to 500k and repeat the above procedure. If the relay still doesn’t energize, this relay will not work for the application. 2 Then make sure the relay de-energizes correctly when electrodes EH and EB are removed from the liquid. R U Note : The maximum level EH on a time delay on filling application can be raised by means of the adjustable time delay from 0.1 to 10 seconds, using function . The minimum level EB on a time delay on emptying application can be lowered by means of the adjustment delay from 0.1 to 10 seconds, using function . The electrode connection point must be sealed to protect against corrosion. In areas where thunderstorms are likely to occur, the electrode lines must be protected. Probe LA9RM201 This probe is of the “suspended” type. It is coaxial ; i.e. in addition to the normal (central) electrode, the stainless steel skirt can also act as ground (reference) electrode, which means that there is no need to install a separate reference probe. In this way, for controlling one level, only one probe is required instead of 2 ; for controlling 2 levels, only 2 probes 2-conductor cable in are required instead of 3. cylindrical sheath The connecting cable must be of the “2-conductor” type with common cylindrical PVC sheath, having a maximum (max. Ø 6.3 mm) diameter of 6.3 mm. The skirt also acts as a “calming chamber”, so avoiding inaccuracy due to an agitated surface of the liquid (waves). Level electrode Maximum operating temperature: 212 °F (100 °C). Control by electrodes Control by probes Reference RM3-LA1 electrode High (skirt) B2 B2 level A1 15 25 B1 B2 B3 B1 B3 EH Low B1 level EB EH EH M EB M M 16 18 28 26 A2 1 level 2 levels EH = High level electrode EB = Low level electrode M = Reference electrode (common) 43 A1 B1 B2 A2 B3 16 18 15 26 28 25 3.05 / 77.5 Supply voltage B1 B2 B3 16 18 15 26 28 25 RM3 Specialty Relays RM3LA1 Liquid Level Control Relay Ordering Information Liquid level control relays Adjustable Sensitivity Control Circuit Catalog Weight time delay Scale Voltage Number (Vac are 50/60 Hz) Seconds Ω lb./(kg) 0.1 to 10 250 to 500 24 to 240 Vac RM3LA111MW 0.54/(0.245) or 24 to 240 Vdc 24 Vac RM3LA111B7 0.54/(0.245) 110 to 130 Vac RM3LA111FG7 0.54/(0.245) 220 to 240 Vac RM3LA111MU7 0.54/(0.245) 380 to 415 Vac RM3LA111QN7 0.54/(0.245) RM3LA1 Liquid level control probe Type of installation Maximum operating Catalog Weight temperature Number lb./(kg) Suspension by cable 212 °F (100 °C) LA9RM201 0.22/(0.100) LA9RM201 Accessories (to be ordered separately) Description Catalog Weight Number lb./(kg) Sealing cover (45mm width) LA9RM301 0.01/(0.005) Replacement Marking Tab LA9D92 0.01/(0.001) LA9RM301 44 RM3 Specialty Relays RM3LA1 Liquid Level Control Relay Application Data Control circuit characteristics Rated supply voltage (Un) Vac 50-60 Hz V 24 to 240 24 110 to 130 220 to 240 380 to 415 Vdc V 24 to 240 – – – – Average consumption at Un Vac VA 2 to 7 3.1 2.7 2.6 3.4 Vdc W 2.4 – – – – Output relay and operating characteristics Number of C/O (Form C) contacts 2 Output relay state Energized when the high level electrode is immersed and de-energized when the low level electrode is no longer immersed Rated operational voltage IEC V 400 (switching) UL V 300 Conventional thermal current IEC A 5 UL A 5 Rated breaking capacity AC-15 230 V-3 A, 400 V-2A NEMA B300 Time delay Adjustable sec. 0.1 to 10 Operating status indication U Green LED on Supply voltage is present to the relay. R Yellow LED on Output relay is energized. Electrode circuit characteristics Maximum electrode voltage a.c. supply V 20 Definition of electrodes Sensitivity scale Maximum electrode Maximum cable Maximum cable and cables (1) Ω current capacity length 250 to 5 k 10 mA 200 nF 1000 m 2.5 to 50 k 4 mA 25 nF 100 m 25 to 500 k 0.5 mA 4 nF 20 m (1) The electrodes may also be built into the probes. The probes are designed to be either fixed to a tank, by means of a bracket with a seal (closed tanks), or suspended by their own electrical connecting cable (bore holes, etc.). Refer to page 43 “Setting-up” (Probe LA9RM201). 45 RM3 Specialty Relays RM3PA1 Insulation Control Relay Operating Principles This device monitors the presence of an insulation resistance on an a.c. supply (with neutral insulated from ground) and the ground connection. • The RM3PA1 insulation control relay is only for equipment monitoring and should not be used for personnel electrical protection. Its detection threshold range is 1 to 110 kW. A fault memory is possible (automatic or manual, local or remote reset), refer to page 47 “Setting-up”. A pushbutton on the front face of the relay allows an “ground fault” TEST to be performed. This test can also be performed remotely, the LED on the front of the relay indicates the various states, refer to page 47 “Setting-up”. Applications on a.c. supply 3-phase supplies : Single-phase supplies : - without neutral conductor, - control circuit of automation equipment, - with artificial neutral, - control circuit, - with insulated neutral. - any auxiliary control circuit galvanically isolated from the mains supply. RM3PA1 1 Resistance range selector (11k or 110k W). RM3 PA1 2 Fine resistance setting potentiometer 1 11k range (potentiometer setting times 1) 110k W range (potentiometer setting times 10) 2 A1 A2 F The red LED labeled with a F indicates that the output 16 relay has been energized when it is illuminated. 15 18 F U U The green LED labeled with a U (Supply Voltage) indicates that supply voltage is present to the RM3 relay when illuminated. Operating principle The supply voltage is connected to terminals A1-A2 or A1-B2. Its value can be identical to that of the supply to be monitored. A continuous voltage (Terminal L) is connected between one phase (or neutral if present) of the installation and ground (s terminal). As soon as a ground insulation fault occurs, it causes a non L1 infinite resistance to appear between the installation and L2 L3 ground. A fault current is established and this current then N passes through the so-called “insulation” resistance. When this current exceeds a value corresponding to the + preset threshold resistance, the output relay is energized with A1 L RM3-PA1 a time delay (refer to curve on page 47 “Setting-up”) and a – A2 fault indicator illuminates on the relay. Purpose of continuous insulation monitor RM3PA1 R1 The main purpose of this device is to indicate the first insulation fault in an installation in order to protect it against K1 R2 incorrect operation due to the appearance of a second fault. On the figure to the left, resistances R1 and R2, corresponding to two successive insulation faults, are in K2 series and can keep K2 energized when contact K1 is open. This incorrect operation can have very serious consequences in some installations. Functional diagram U supply A1-A2/B2 Reset S1/S2 Remote { Test S1/ s On RM3 Test Reset Insulation resistance 15-18 Relay 15-16 t t T t T 46 RM3 Specialty Relays RM3PA1 Insulation Control Relay Wiring, Approximate Dimensions, and Setup Information Wiring Connection and values of the 2 resistance ranges to be Supply voltages : controlled R < s Mixed Vac or Vdc RM3PA101 L to s 1 to 11 kΩ A1-A2 24 to 240 V 10 to 110 kΩ Dual voltage Vac 50/60 Hz depending on setting A1-B2 110 to 130 V of switch 1 A1-A2 220 to 240 V A1 15 S1 S2 s L, s Insulation measurement (see table to the right) S1- s Remote TEST S1-S2 Remote Reset 15-18 C/O (Form C) contact 16 18 L B2 A2 15-16 of output relay Approximate dimensions Inches Dimensions MM 3.94 / 100 1.77 / 45 Setup information Basic scheme of the installation Fault memory External Test Short-circuiting of terminals S1 and S2 (see scheme to the right) allows the fault to External Reset be memorized as soon as it appears, even if only briefly. The duration of the fault must exceed the response time of the relay (see curve below) for it to be detected. s A1 15 S1 S2 Installation controlled If this short-circuiting is achieved by means of a N/C pushbutton, this acts as the P S remote reset button (if the fault has disappeared). Manual local resetting is L1 achieved by briefly pressing (less than 0.5 s) the RESET/TEST button on the front R < s L2 of the relay. L3 N 16 18 L B2 A2 Test When the installation being controlled does not have an insulation fault, pressing the RESET/TEST button on the relay causes 2 simultaneous actions: Various schemes depending on maximum voltages - the measuring input terminal not connected to ground (L) is disconnected from • The RM3PA1 insulation control relay can only monitor circuits with: the line being controlled, • A maximum of 415 VAC phase-phase when terminal L is connected to the - a resistance (internal) of 820 W is connected to this input in order to simulate an neutral of a 3 phase circuit. insulation fault. • A maximum of 240 VAC phase-phase when terminal L is connected to a The relay must then react in the same way as for a real fault. phase of a 2 or 3 phase circuit. A N/O pushbutton may be connected to terminals S1 and s which will act as the remote test button and which will have the same effect as the built-in test button 380 to 415 V without neutral 220 to 415 V with insulated neutral P S P R kΩ S is (See scheme to the right). Sec L1 L1 1 2 4 6 10 20 40 60 100 L2 L2 3 L3 L3 tA 3 x R N 2.5 RM3 PA1 artificial A1 L A1 L neutral c 2 c RM3-PA1 RM3-PA1 A2 s A2 1 s 1.5 R = 82 kΩ /5 W at 415 V Note : one single RM3 per supply 2 68 kΩ / 5 W at 380 V monitored 1 A1 A2 75 kΩ / 5 W at 400 V 16 15 18 0.5 F 110 to 240 V single-phase 220 to 240 V without neutral U P S 0.1 1 10 100 L1 P S L2 Rim kΩ t = Delay on energization L3 A A1 L = Insulation resistance measured A1 L R im c c RM3-PA1 = Insulation resistance threshold RM3-PA1 A2 s R A2 s is 47 A1 L B2 A2 s 16 18 15 3.05 / 77.5 Supply voltage 24…240 V c/a(MW) 220…240 V c/a(FU) 110…130 V c/a(FU) L 16 18 15 RM3 Specialty Relays RM3PA1 Insulation Control Relays Ordering Information Insulation control relay Insulation Control Circuit Catalog Weight Measurement Voltage Number k Ω V lb./(kg) 1 to 110 24 to 240 Vac 50/60 Hz RM3PA101MW 0.55/(0.250) or 24 to 240 Vdc 110 to 130 Vac 50/60 Hz RM3PA101FU7 0.55/(0.250) or 220 to 240 Vac 50/60 Hz RM3LA1 Accessories (to be ordered separately) Description Catalog Weight Number lb./(kg) Sealing cover (45mm width) LA9RM301 0.01/(0.005) Replacement Marking Tab LA9D92 0.01/(0.001) LA9RM301 48 RM3 Specialty Relays RM3PA1 Insulation Control Relay Application Data Environment Conforming to standards UTE 63080, DIN 0413 (part 2), VDE 0413 part. 2 Control circuit characteristics Rated supply voltage (Un) Vac 50-60 Hz V 24 to 240 110 to 130 220 to 240 Vdc V 24 to 240 – – Average consumption at Un Vac VA 4.5 2.5 2.5 Vdc W 4.5 – – Output relay and operating characteristics Number of C/O (Form C) contacts 1 Output relay state Energized on detection of an insulation fault Rated operational voltage IEC V 400 (switching) UL V 300 Conventional thermal current IEC A 6 UL A 5 Rated breaking capacity AC-15, 250 V A 5 NEMA B300 Time delay Delay on energization See curve page 47. Relay resetting threshold Fixed setting 1.6 times the insulation resistance value set (tripping of relay) Operating status indication U Green LED on Supply Voltage (U supply) is present to the relay. F Red LED on Relay is energized on detection of fault Measuring input characteristics Setting range kΩ 1 to 11, 10 to 110 kΩ Minimum internal resistance Vac or Vdc kΩ 100 Internal test resistance Ω 820 Maximum insulation voltage Between L and s V 415 Measurement voltage Vdc V 30 maximum Maximum length of m 10 Test or Reset cable 49 RM3 Specialty Relays RM3EA1 Sensitive Contact Protection Relay Operating Principles This device relays, protects and amplifies a low level “Discrete” output. It may be used with or without memory function. The adjustable time delay from 0.05 to 30 seconds avoids oscillations of the relay in the event of interference or bouncing of the contact to be protected. It can be controlled by a mechanical contact or by a 3-wire solid state switch (see examples on page 51, “Setting-up”). Applications : - protection, - ensuring reliability, - amplification of low level outputs on measuring devices, sensors, probes etc. Presentation 1 Time delay range selector switch (0.05 to 1 second and 1.5 to 30 seconds). RM3EA1 RM3 EA1 2 Fine adjustment time delay potentiometer. 1 R The yellow LED labeled with an R indicates that the A1 A2 16 output relay has been energized when it is illuminated. 15 18 2 26 U The green LED labeled with a U (Supply Voltage) 25 28 indicates that supply voltage is present to the RM3 relay when illuminated. R U Operating principle The supply voltage is connected to terminals A1-A2. Protection of “Discrete” contacts The RM3’s output relay is energized when terminals Y1-Y2 are connected to the contact to be protected and this contact is closed. A1 Contact to RM3-EA A2 be protected Protection of contacts with memory (latching) The RM3’s output relay is energized when terminals Y1-Y3 are connected to the contact to be protected and this contact is closed for a time > 20 ms. It remains energized after opening of Y1-Y3. A1 It de-energizes when Y1 - Y4 are short-circuited. Contact to RM3-EA A2 be protected Functional diagram U supply A1/A2 Y1/Y2 Contact Y1/Y3 to be protected Y1/Y4 15-18 15-16 Relay 25-28 25-26 t t t t : time delay 50 Supply Supply Y3 Y1 Y1 Y2 Y4 RM3 Specialty Relays RM3EA1 Sensitive Contact Protection Relay Wiring, Approximate Dimensions, and Setup Information Wiring Y1 Connection and type of protection A1-A2 Supply voltage RM3EA1•1 Y1-Y2 Protection of “Discrete” A1 15 25 Y2 Y3 Y4 contact Y1, Y2, Connection of contacts to be Y3, Y4 monitored (see table to the right) Protection of contact with st 15-18 1 C/O (Form C) contact of output relay memory “Latching” : 15-16 Y1-Y3 Energization nd 25-28 2 C/O (Form C) contact of output relay Y1-Y4 De-energization 16 18 28 26 Y1 A2 25-26 Approximate dimensions Inches Dimensions MM 3.94 / 100 1.77 / 45 Setup information Energization by 3-wire NPN solid state switch On : the relay is energized (Y1-Y3). Off : the relay is de-energized (Y1-Y4). + UB Y1 NPN Y3/– UB Y4/– UB Relays having two contacts with common point may be connected to two separate RM3EA1 relays. The common point of the contacts must be connected to terminal Y2 of each RM3EA1. (RM3-EA N°1) Y2 (RM3-EA N°2) Y1 (RM3-EA N°1) Y1 (RM3-EA N°2) 51 A1 Y2 Y3 A2 Y4 16 18 15 26 28 25 3.05 / 77.5 RM3 Specialty Relays RM3EA1 Sensitive Contact Protection Relay Ordering Information Sensitive contact protection relays Time Delay Control Circuit Catalog Weight Voltage Number Seconds Vac 50/60Hz lb./(kg) 0.05 to 30 24 RM3EA111B7 0.68/(0.310) 110 to 130 RM3EA111FG7 0.68/(0.310) 220 to 240 RM3EA111MU7 0.68/(0.310) 380 to 415 RM3EA111QN7 0.68/(0.310) None 24 RM3EA101B7 0.68/(0.310) 110 to 130 RM3EA101FG7 0.68/(0.310) 220 to 240 RM3EA101MU7 0.68/(0.310) 380 to 415 RM3EA101QN7 0.68/(0.310) RM3EA1 Accessories (to be ordered separately) Description Catalog Weight Number lb./(kg) Sealing cover (45mm width) LA9RM301 0.01/(0.005) Replacement Marking Tab LA9D92 0.01/(0.001) LA9RM301 52 RM3 Specialty Relays RM3EA1 Sensitive Contact Protection Relay Application Data Control circuit characteristics Rated supply voltage (Un) Vac 50-60 Hz V 24 110 to 130 220 to 240 380 to 415 Average consumption at Un Vac VA 3.4 3.4 3.4 3.4 Output relay and operating characteristics Number of C/O (Form C) contacts 2 Output relay state See diagram on page 50 and the note (1) below. Rated operational voltage IEC V 400 (switching) UL V 300 Conventional thermal current IEC A 5 UL A 5 Rated breaking capacity AC-15 230 V-3 A, 400 V-2 A NEMA B300 Time delay on energization Adjustable sec. 0.05 to 30 Time delay on de-energization ms 50 Minimum closing time for ms 20 memory (latching) Operating status indication U Green LED on Supply Voltage (U supply) is present to the relay. R Yellow LED on Relay is energized. Measuring input characteristics Resistance Energization “Discrete” contacts Y1-Y2 < 6.5 kΩ guaranteed “Latching” contacts Y1-Y3 < 6.5 kΩ De-energization “Discrete” contacts Y1-Y2 > 19 kΩ guaranteed “Latching” contacts Y1-Y4 < 16 kΩ No-load voltage Vdc current V <10 Switching current mA < 3 Continuous voltage applied 3-wire control, V < 30 (maximum) Vdc current (1) If circuits Y1-Y3 and Y1-Y4 are closed, the output relay is energized. The relay memory is reset to zero when the power supply is switched off. In the event of a power failure, the relay de-energizes and is re-energized at switch-on only if circuit Y1-Y3 is closed. 53 RM3 Specialty Relays Notes: 54 RM3 Specialty Relays Notes: 55 RM3 Specialty Relays Notes: 56 From single products to complete systems, look to Square D. Square D Company is a leading manufacturer and supplier of electrical distribution, automatic and industrial control products. The full line of Square D and Telemecanique brand products are available from an extensive network of Square D distributors located throughout North America. Square D Company is part of Groupe Schneider, a global manufacturer of electrical distribution, automation and industrial equipment. Square D has been serving indus- trial and construction markets, as well as public utilities, individual consumers and government agencies for over 90 years. We offer unsurpassed quality, innovative design and a committed staff of trained sales representatives and service techni- cians willing to stand behind every product we sell. For further information on how we can help fill your electrical needs, call your local Square D field representative or au- thorized Square D distributor. Square D Company P.O. Box 27446 Raleigh, N.C. 27611, USA ® Telemecanique is a registered trademark of Telemecanique. 8430CT9601 June 1996 Printed in USA 5M FP 6/96 © 1996 Square D All Rights Reserved
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the RM3 Series have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Manufacturers







What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods