TELEMECANIQUE RE7MY13MW

Image of TELEMECANIQUE RE7MY13MW

Description

TELEMECANIQUE-RE7MY13MW-TIMER 300V 5AMP RE7 +OPTIONS

Part Number

RE7MY13MW

Price

Request Quote

Manufacturer

TELEMECANIQUE

Lead Time

Request Quote

Category

TBD

Specifications

Contacts material

90/10 silver nickel contacts

Discrete output type

Relay

Maximum switching voltage

250 V AC/DC

Mechanical durability

20000000 cycles

Minimum pulse duration

20 ms

Repeat accuracy

+/- 0.2 %

Reset time

50 ms

Setting accuracy of time delay

+/- 10 % of full scale

Tightening torque

0.6...1.1 N.m

Voltage range

0.85...1.1 Us

Width pitch dimension

22.5 mm

Datasheet

pdf file

tele-re7my13my-ds1-962038671.pdf

147 KiB

Extracted Text

Product data sheet RE7MY13MW Characteristics time delay relay 8 functions - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Zelio Time Product or component Industrial timing relay type Contacts type and com- 2 C/O position Component name RE7 Time delay type A C D Di H Qg Qt W Time delay range 0.05 s...300 h [Us] rated supply volt- 24...240 V AC/DC 50/60 Hz age Complementary Discrete output type Relay Contacts material 90/10 silver nickel contacts Width pitch dimension 22.5 mm Voltage range 0.85...1.1 Us Connections - terminals Screw terminals, clamping capacity: 2 x 1.5 mm² flexible with cable end Screw terminals, clamping capacity: 2 x 2.5 mm² flexible without cable end Tightening torque 0.6...1.1 N.m Setting accuracy of time delay +/- 10 % of full scale Repeat accuracy +/- 0.2 % Temperature drift < 0.07 %/°C Voltage drift < 0.2 %/V Minimum pulse duration 20 ms Reset time 50 ms Maximum switching voltage 250 V AC/DC Mechanical durability 20000000 cycles [Ith] conventional free air thermal current 8 A [Ie] rated operational current <= 2 A DC-13 24 V at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660 <= 3 A AC-15 at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660 <= 0.1 A DC-13 250 V at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660 <= 0.2 A DC-13 115 V at 70 °C conforming to IEC 60947-5-1/1991/VDE 0660 Minimum switching capacity 12 V/10 mA Input voltage < 60 V X1Z2 terminal(s) < 60 V Y1Z2 terminal(s) Maximum switching current 1 mA X1Z2 terminal(s) 1 mA Y1Z2 terminal(s) Input compatibility 3/4 wires sensors PNP/NPN without internal load, cable length: <= 50 m X1Z2 terminal(s) 3/4 wires sensors PNP/NPN without internal load, cable length: <= 50 m Y1Z2 terminal(s) Potentiometer characteristic Linear 47 kOhm (+/- 20 %), 0.2 W, cable length: <= 25 m Z1Z2terminal(s) Marking CE Overvoltage category III conforming to IEC 60664-1 Jun 28, 2011 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. [Ui] rated insulation voltage 250 V between contact circuit and control inputs IEC certified 250 V between contact circuit and power supply IEC certified 300 V between contact circuit and control inputs CSA certified 300 V between contact circuit and power supply CSA certified Supply disconnection value > 0.1 Uc Operating position Any position without derating Surge withstand 2 kV conforming to IEC 61000-4-5 level 3 Power consumption in VA 2 VA 24 V 6 VA 240 V 2.5 VA 48 V 3.2 VA 110 V Power consumption in W 1 W 48 V 2 W 24 V 2 W 240 V 3.2 W 110 V Peak current 0.001 kA for 30 s on energisation Terminal description (15-16-18)OC_OFF (25-26-28)OC_OFF (A1-A2)CO (X1)UNUSED (Y1)UNUSED (Z1)UNUSED (Z2)UNUSED CAD overall width 22.5 mm CAD overall height 78 mm CAD overall depth 80 mm Product weight 0.15 kg Environment Immunity to microbreaks 3 ms Standards EN/IEC 61812-1 Product certifications CSA GL UL Ambient air temperature for storage -40...85 °C Ambient air temperature for operation -20...60 °C Relative humidity 15...85 % (3K3) conforming to IEC 60721-3-3 Vibration resistance 0.35 mm (f = 10...55 Hz) conforming to IEC 60068-2-6 Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 IP degree of protection IP20 (terminals) IP50 (housing) Pollution degree 3 conforming to IEC 60664-1 Dielectric strength 2.5 kV Non-dissipating shock wave 4.8 kV Resistance to electrostatic discharge 6 kV (in contact) conforming to IEC 61000-4-2 level 3 8 kV (in air) conforming to IEC 61000-4-2 level 3 Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3 level 3 Resistance to fast transients 2 kV conforming to IEC 61000-4-4 level 3 Disturbance radiated/conducted CISPR11 group 1- class A CISPR22 - class A RoHS EUR status Compliant RoHS EUR conformity date 0624 2 Product data sheet RE7MY13MW Technical Description Function A: Delay on Energisation Description The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) Function C: Timing After Opening of Control Contact Description After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) Function D: Symmetrical Flashing, Start with Output in Rest Position Description Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T. The second output can be either timed or instantaneous. Function: 1 Output 3 Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) Function Di: Symmetrical Flashing, Start with Output in Operating Position Description Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T. The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) Function H: Timing on Energisation Description On energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.) Function Qg: Star-Delta Timing Description Timing for star-delta starter with contact for switching to star connection. Function: 1 Output 4 Function Qt: Star-Delta Timing Description Timing for star-delta starter with double On-delay period. Function: 1 Output Function W: On-Delay After Opening of Control Contact Description After power-up and opening of the control contact, the output(s) close(s) for a timing period T. At the end of this timing period the output(s) revert(s) to its/their initial state. The second output can be either timed or instantaneous. Function: 1 Output Function: 2 Outputs 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.). Legend Relay de-energised Relay energised Output open Output closed C Control contact G Gate R Relay or solid state output R1/ 2 timed outputs R2 R2 The second output is instantaneous if the right position is selected inst. T Timing period Ta Adjustable On-delay Tr Adjustable Off-delay U Supply 5 Product data sheet RE7MY13MW Dimensions Drawings Width 22.5 mm Rail Mounting Screw Fixing 6 Product data sheet RE7MY13MW Connections and Schema Internal Wiring Diagram Recommended Application Wiring Diagram Start on Energisation 1 Supply 2 12…48 V 3 24 V Recommended Application Wiring Diagram Start by External Control 1 Supply 2 12…48 V 3 24 V Recommended Application Wiring Diagram External Control of Partial Stop 1 Supply 2 12…48 V 3 24 V Control of Several Relays 7 Control of several relays with a single external control contact Connection of Potentiometer Connection Precautions WARNING UNEXPECTED EQUIPMENT OPERATION No galvanic isolation between supply terminals and control inputs. Failure to follow these instructions can result in death, serious injury, or equipment damage. 8 Product data sheet RE7MY13MW Performance Curves Performance Curves A.C. Load Curve 1 Electrical durability of contacts on resistive loading millions of operating cycles X Current broken in A Y Millions of operating cycles A.C. Load Curve 2 Reduction factor k for inductive loads (applies to values taken from durability curve 1). X Power factor on breaking (cos ϕ) Y Reduction factor k Example: An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ = 0.3. For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles. As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2. For cos ϕ = 0.3: k = 0.6 The electrical durability therefore 6 becomes:1.5 10 operating cycles x 0.6 = 900 000 operating cycles. D. C. Load Limit Curve X Current in A Y Voltage in V 1 L/R = 20 ms 2 L/R with load protection diode 3 Resistive load 9

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the RE7MY13MW have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Telemecanique ATS01N232QN 380-415VAC, 32 Amp Soft Start Relay

product

Telemecanique DF6AB10 Fuse Holder, DF6 - 1P - 32 A - for fuse NFC 10 x 38 mm

product

Telemecanique GB2-CB07 2 Amp, 1 Pole Circuit Protector

product

Telemecanique GBS PREVENTA Series Safety Relays

product

Telemecanique GNKL PREVENTA Series Safety Relays

product

Telemecanique J20C40 Relay - RELAY CONTROL WITH CONVERTIBLE CONTACTS