TAMURA OLD-12/15AA
Specifications
Commercial/Medical
Medical
Efficiency
55(Typ) %
Input Frequency
47 to 63 Hz
Input Voltage
100 VAC, 120 VAC, 220 VAC, 230 VAC, 240 VAC
Mounting Style
Chassis
Number of Outputs
2
Output Current (Channel 1)
1 A
Output Current (Channel 2)
0.8 A
Output Power Rating
12 W
Output Voltage (Channel 1)
12 V
Output Voltage (Channel 2)
+/- 15 V
Type
Linear Power Supplies
Features
- 100/120/220/230/240VAC inputs.
- 5V OVP Built-in.
- MTBF to 460,000 Hrs.
- Optional OVP Module.
- Overload Protection
- Remote Sensing
- Short Circuit Protection.
- UL 1950, UL544, CSA 1402C,
- VDE 0805, EN60 950.
Datasheet
Extracted Text
SINGLE AND MULTIPLE OUTPUT LINEAR POWER SUPPLIES File No.s 3206,3208, 3210, File No. E140527 3216, 3218, 3257, 3212, File No. LR69809 3214,3257, 3259, 3261 SPECIFICATIONS AC INPUT LINE REGULATION STABILITY User-selectable for 100/120/220/230-240 VAC, 47-63 Hz. ±0.05% for a 10% line change. ±1.0% for models OLD- ±0.3% for 24-hour period after 1-hour warm-up. Factory set at 120 VAC. Tolerances are: +10% and -13% 12B and OLD-15B. for 100, 120, 220 and 240 VAC input; + 15% and -10% MTBF for 230 VAC input. Derate output current 10% for 50 Hz LOAD REGULATION Per MIL-HDBK-217D at 100% load, 120 VAC line and operation. Input must be fused. See fuse rating and ±0.05% for a 50% load change. ±1.0% for models OLD- 25ûC ambient temperature. jumper information table 12B and OLD-15B. CASE SIZE MTBF RATINGS TRANSIENT RESPONSE AC INPUT FUSE RATINGS µ - Case # Outputs MTBF hrs Case 100 120 220 240 nal output voltage. Size VAC VAC VAC VAC B 1 300,000 B 0.63A 0.5A 0.35A 0.25A SHORT CIRCUIT & OVERLOAD PROTECTION B 2 460,000 OLS-24B 1.0A 0.8A 0.5A 0.35A Automatic current limit/foldback. Output recovers upon C 1.6A 1.0A 0.8A 0.5A C 1 300,000 removal of fault condition. N 2.0A 2.0A 1.0A 1.0A N 1 260,000 D 2.5A 2.0A 1.25A 1.0A N 2 150,000 OVERVOLTAGE PROTECTION 131 3.0A 3.0A 1.6A 1.6A Built-in on all main 5V outputs. Factory set at 6.2V ±0.4V. D 1 250,000 AA 0.63A 0.5A 0.35A 0.25A Other outputs use optional overvoltage protection module, OLD-24AA 1.0A 0.8A 0.5A 0.35A D 3 120,000 OVP-1. OLT-522AA 1.0A 0.8A 0.5A 0.35A AA 2 175,000 BB 1.6A 1.0A 0.8A 0.5A AA 3 140,000 OPTIONAL OVERVOLTAGE PROTECTION CC 2.5A 2.0A 1.25A 1.0A OVP module, model OVP-1, may be used with any output BB 2 160,000 not supplied with factory built-in OVP . Adjustable range, 6.4 CC 2 155,000 AC INPUT JUMPER INFORMATION to 34V . Maximum current rating 8.0A. Module may be used 131 3 120,000 to protect dual outputs (±12 or ±15). Recommended trip AC Input (47 to 63 Hz) point is 1 15 to 133% For use at 100 120 220 230/240 TEMPERATURE RATINGS of output voltage. VAC VAC VAC VAC Operating: 0ûC to +50ûC full-rated load. Jumper 1 & 3 1 & 3 Derate to 40% at 70ûC. 2 & 4 2 & 4 2 & 3 2 & 3 Storage: -40ûC to +85ûC. Apply AC 1 & 5 4 & 1 1 & 5 4 & 1 TEMPERATURE COEFFICIENT ±0.03%/0C maximum. 100V 120V 220V 230/240V EFFICIENCY OVP-1 Outline ¥¥¥¥¥ ¥¥¥¥¥ ¥¥¥¥¥ ¥¥¥¥¥ Typical effic iency: 5V output, 45%; 12 and 15V output, 42315 42315 42315 42315 55%; 24V to 250V outputs:60%. 4 2 3 1 5 VIBRATION Per MIL-STD-810C, Method 514, Procedure X CA T. G-1. SHOCK DC OUTPUT Per MIL-STD-810C, Method 516, Procedure V. See power output ratings for specific models. Adjustable range ±5% minimum. See voltage adjust specifications. DIMENSIONS AND WEIGHT See dimensional drawings. NOISE AND RIPPLE VOLTAGE ADJUST 5V through 15V models: 5.0 mV p-p max. OLD-12B and Adjustable range ±5% minimum on fixed output models. SAFETY OLD-15B: 0.2% of output voltage p-p max. 24V models: 3 Voltage adjustable over range indicated (±5%) for wide Compliance to intÕl safety regulations for power supply mV p-p plus 0.2% of output voltage max. range models. Voltage non-adjustable on models OLD- specs. UL recognized, file #E102103. CSA certfied, 122B and OLD-15B. Models OLD-24AA, OLD-24BB and cert. #LR69809. VDE registered: OLS-B, file #3212; REMOTE SENSING OLD-24CC are factory set at 24V. Adding jumper allows OLS-C, #3208; OLS-N, #3210; OLS-D, #3214; OLD-B, Provided on most outputs. Open sense lead protection 18 to 20V adjustable output. #3218; OL T- F, #3206; OLD-24AA & 24BB, #3216; built-in. Exceptions are noted with an “*”. See output power OLD-5AA, 512AA, 12/15AA & OL T-522A, #3257; OLD- rating table for specific model. 5BB, 12/15BB & 512BB, #3259; OLD-5CC, 24CC, EMI/RFI 12/15CC & 512CC, #3261. Inherently low conducted and radiated noise levels. Original Connection Move To Change Output V oltage OUTPUT TAP AND PCB VOLTAGE CHANGES SHOR T J1 & J2 FOR ALL. CHG T AP & OPEN J1, J2 & J3. CHG T AP & OPEN J1 & J2. OL T-522AA: SHORT J1 FOR -5V . OL T-522F: TA P TAP CHG ON OLD-24CC ONL Y SHOR T J3 FOR -5V . CHG & OPEN J1. J2 & J3 SHORT J3 FOR -5V . (C ) (+18~20 )(+24) (C ) (-18~20) (-24) (± 12) (± 12) (± 15) (± 15) (C) (+12) (+15) (C) (-12) (-15) (+12) (C) (-12) (+15) (-15) A AT A B BT B A AT A B BT B A AT A B BT B A AT A B BT B C C Fig. 1 Models OLD-24AA, 24BB, 24CC Fig. 2 Models OLD-12/15AA, 12/15BB Fig. 3 Models OLD-12/15CC Fig.4 Models OL T-522AA, 522F For more detailed information and individual product specification sheets visit www.tamuracorp.com. Tamura Corporation of America ¥ P.O. Box 892230 ¥ Temecula, CA 92589-2230 ¥ Tel: 951-699-1270 ¥ FAX: 951-676-9482 ¥ sales@tamuracorp.com www.tamuracorp.com 20| Standard Products Catalog SINGLE AND MULTIPLE OUTPUT LINEAR POWER SUPPLIES Tamura has set reliability standards through component upgrade design. Critical specs such as temperature, voltage and current have been derated so that, for example, 105ÁC instead of 85ÁC electrolytic caps are used. The result is the highest available MTBF as calculated by MIL-HDBK-217D at full load, 120VAC and 25ÁC . File No.s 3206,3208, 3210, File No. E140527 3216, 3218, 3257, 3212, File No. LR69809 3214,3257, 3259, 3261 U UL L5 54 44 4 f fo or r M ME ED DI IC CA AL L & & D DE EN NT TA AL L DUAL OUTPUT MODELS 2,3 V O LTA G E , C U R R E N T M O D E L P O W E R - O N E C A S E 1 OUTPUT 1 OUTPUT 2 N O. T Y P E S I Z E Ð 5 VO L T S OLD-5AA V HAA5-1.5/OVP-A 5V,1.5A* -5V,1.5A* AA OLD-5BBV HBB5-3/OVP-A 5V,3.0A* -5V,3.0A* BB OLD-5CCV HCC5-6/OVP-A 5V,6.0A -5V,6.0A CC Ð12 o r 15 VOLT S OLD-12B HAD12-0.4-A 12V, 0.4A* -12V ,0.4A* B Features OLD-15B HAD15-0.4-A 15V, 0.4A* -15V ,0.4A* B SINGLE OUTPUT MODELS Ð12/15 VOLT S ´ MTBF to 460,000 Hrs. 2 OLD-12/15AA HAA15-0.8-A 12V, 1.0A -12V ,1.0A AA M O D E L P O W E R - O N E V O LTA G E , C A S E ´ UL 1950, UL544, CSA 1402C, N O. T Y P E C U R R E N T S I Z E jumper chg: 15V,0.8A -15V ,0.8A ´ VDE 0805, EN60 950. 5 V O LT S or -5V, 0.4A OLS-5BV HB5-3/OVP-A 5V, 3.0A B ´ 100/120/220/230/240V AC inputs. OLD-12/15BB HBB15-1.5-A 12V, 1.7A -12V , 1.7A BB OLS-5CV HC5-6/OVP-A 5V, 6.0A C jumper chg: ´ Remote Sensing. OLS-5NV HN5-9/OVP-A 5V, 9.0A N 15V, 1.5A -15V , 1.5A OLS-5DV HD5-12/OVP-A 5V, 12.0A D ´ 2 Y ear Warranty. or -5V, 0.7A 12 VOLT S OLD-12/15CC HCC15-3-A 12V, 3.4A -12V , 3.4A CC ´ 5V OVP Built-in. OLS-12B HB12-1.7-A 12V, 1.7A B jumper chg: OLS-12C HC12-3.4-A 12V, 3.4A C ´ Optional OVP Module. 15V, 3.0A -15V , 3.0A OLS-12N HN12-5.1-A 12V, 5.1A N ´ Short Circuit Protection. Ð24 o r 18 to 20 VOLT S OLS-12D HD12-6.8-A 12V, 6.8A D OLD-24AA HAA24-0.6-A 24V, 0.6A* -24V ,0.6A* AA ´ Overload Protection 15 VOLT S jumper chg: OLS-15B HB15-1.5-A 15V, 1.5A B ´ Burn-in. 1820V , 0.4A -1820V , 0.4A OLS-15C HC15-3-A 15V, 3.0A C OLD-24BB HBB24-1.2-A 24V,1.2A* -24V ,1.2A* BB ´ V oltage Adjust: Ð5% min. OLS-15N HN15-4.5-A 15V, 4.5A N jumper chg: OLS-15D HD15-6-A 15V, 6.0A D ´ Line/Load Reg: Ð0.05% typ. 1820,0.9A -1820V ,0.9A 24 VOLT S OLD-24CC HCC24-2.4-A 24V,2.4A -24V ,2.4A CC ´ Noise/Ripple: 5.0mVp-p typ. OLS-24B HB24-1.2-A 24V, 1.2A B jumper chg: ´ Tr ansient Response: 50 sec OLS-24C HC24-2.4-A 24V, 2.4A C 1820V ,1.8A -1820V ,1.8A OLS-24N HN24-3.6-A 24V, 3.6A N (50% load chg.) 5 & 12 to 15 VOLT S OLS-24D HD24-4.8-A 24V, 4.8A D OLD-512AA HAA512-A 5V,2.0A* +1215V ,0.5A* AA ´ Stability: Ð0.3%for 24 hours. O V P M O D U L E OLD-512BB HBB512-A 5V,3.0A +1215V ,1.25A BB OVP-1 OVP-12 6.4V34V OVP ´ 50ÁC Rated Full Load. OLD-512CC HCC512-A 5V,6.0A +1215V ,2.5A CC ´ T emp coef: Ð0.3%/ÁC max. TRIPLE OUTPUT MODELS ´ V ibration: MIL-STD-810C. 2,3 V O LTA G E C U R R E N T MODE L P O W E R - O N E C A S E ´ Shock: MIL-STD-810C. 1 NO. T Y P E OUTPUT 1 OUTPUT 2 OUTPUT 3 S I Z E 5 & Ð12 TO 15 VOLT S OL T-522AA HT AA-16W -A 5V,2.0A* 1215V ,0.4A* -(1215)V ,0.4A* AA 4 MECHANICAL DIMENSIONS jumper chg: -5V,0.4A OL T-522F CP131-A 5V,8.0A 12V, 1.7A -12V , 1.7A 131 CASE DIMENSIONS WT jumper chg: 15V, 1.5A -15V , 1.5A SIZE (L" xW"x H") (LBS) -or- B 4.87X4.00X2.07 2 5V, 0.7A C 5.62X4.87X2.95 4 Note 1: OVP built-in on main 5V output of multiple output D 9.00X4.87X3.28 7.5 units. Use OVP-1 module (up to 34V combined for N 7.00X4.87X3.20 6 other outputs). AA 6.50X4.00X2.07 2 Note 2: Other industry standard output voltages available BB 7.00X4.78X2.95 4 on a special order. CC 9.38X4.87X3.28 7 Note 3: * indicates remote sense not provided . 131 11.0X4.87X2.75 9 Note 4: Indicates OLT-522AA short J1 for -5V. OVP-1 1.58X1.58X0.50 For more detailed information and individual product specification sheets visit www.tamuracorp.com. Tamura Corporation of America ¥ P.O. Box 892230 ¥ Temecula, CA 92589-2230 ¥ Tel: 951-699-1270 ¥ FAX: 951-676-9482 ¥ sales@tamuracorp.com www.tamuracorp.com Standard Products Catalog |21
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the OLD-12/15AA have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods