SUNON FANS MC25100V2-000U-A99

Description
Sunon Fans MC25100V2-000U-A99 FAN 25X10MM 5VDC 0.43W 3CFM | Series - DR (ME), DRMagLev | 5VDC - Voltage | 3.0 CFM (0.085m /min) | 0.180 in H2O (44.8 Pa) - Static Pressure | Bearing Type - Vapo Bearing | Fan Type - Tubeaxial | 0.43W - Power (Watts) | 10000 RPM | Square - 25mm L x 25mm H x 10mm W - Dimensions | 0.017 lb (7.71g) - Weight |
Part Number
MC25100V2-000U-A99
Price
Request Quote
Manufacturer
SUNON FANS
Lead Time
Request Quote
Category
PRODUCTS - M
Features
- Dust resistance
- High temperature endurance
- Higher reliability
- Long service life
- Low noise level
- Vapo bearing™
Datasheet
Extracted Text
SUNON SPECIFICATION FOR APPROVAL CUSTOMER : : MOTOR TYPE : MagLev Motor Fan DESCRIPTION 25X25X10 mm DIMENSIONS : M O D E L : MC25100V2-0000-A99 SUNON SPEC. NO. : D02018970G-00 CUSTOMER : APPROVAL NO. APPROVED BY : CUSTOMER (AUTHORIZED) SPEC.NO D02018970G-00 ISSUE DATE 06.17.2009 Kiddy Dolphin DRAWN CHECKED APPROVED Jacky EDITION 1 5/26 keko REVISION DATE 05.26.2010 E.SPEC E10900189 建準電機工業股份有限公司 SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD. NO. 30, LN. 296, XINYA RD., QIANZHEN DIST., TEL:886-7-8135888 KAOHSIUNG CITY 80673, TAIWAN (R.O.C) FAX:886-7-8230505/8230606/8231010 URL:http://www.sunon.com E-mail: sunon@email.sunon.com.tw 建 準 電 機 SUNONWEALTH 2010.06.15 Page 1 of 14 I. MODEL NUMBERING SYSTEM 25 10 0 V 2 - 0000 MC - A99 Voltage Speed Series Code X:Super High 0: 5VDC Function Code 1: High 1: 12VDC 2: Medium 2: 24VDC 3: Low Customer Code 3: 36VDC 4: 48VDC Bearing V: Vapo B: 2 Ball O: 1Ball S: Sleeve Size Thickness 編碼 尺寸(mm) 編碼 尺寸(mm) 編碼 尺寸(mm) 編碼 尺寸(mm) 01~09 1~9 A0~A9 100~109 K0~K9 200~209 V0~V9 300~309 10~19 10~19 B0~B9 110~119 L0~L9 210~219 W0~W9 310~319 20~29 20~29 C0~C9 120~129 M0~M9 220~229 X0~X9 320~329 30~39 30~39 D0~D9 130~139 N0~N9 230~239 Y0~Y9 330~339 40~49 40~49 E0~E9 140~149 P0~P9 250~259 Z0~Z9 340~349 50~59 50~59 F0~F9 150~159 Q0~Q9 260~269 60~69 60~69 G0~G9 160~169 R0~R9 270~279 70~79 70~79 H0~H9 170~179 S0~S9 280~289 80~89 80~89 I0~I9 180~189 T0~T9 290~299 90~99 90~99 J0~J9 190~199 U0~U9 290~299 建 準 電 機 SUNONWEALTH 2010.06.15 Page 2 of 14 II. SPECIFICATION 1. MECHANICAL CHARACTERISTIC Single phase , 8-poles Brushless DC motor MOTOR DESIGN BEARING SYSTEM Vapo bearing system See Page 6 DIMENSIONS MATERIALS OF FRAME Thermoplastic PBT of UL 94V-0 Thermoplastic PBT of UL 94V-0 MATERIALS OF FAN BLADE Counter-clockwise viewed from front of fan blade DIRECTION OF ROTATION MOUNTING HOLES Diameter 2.8 mm in 3 holes 7.5 g WEIGHT 2. ELECTRIC CHARACTERISTIC RATED VOLTAGE 5 VDC RATED CURRENT 85 mA / Max. 98 mA RATED POWER CONSUMPTION 0.43 WATTS / Max. 0.49 WATTS OPERATING VOLTAGE RANGE 2.5~6 VDC STARTING VOLTAGE 2.5 VDC (25 deg. C POWER ON/OFF) OPERATING TEMPERATURE RANGE -10 to + 70 deg. C STORAGE TEMPERATURE RANGE -40 to + 70 deg. C 建 準 電 機 SUNONWEALTH 2010.06.15 Page 3 of 14 3. PERFORMANCE CHARACTERISTIC RATED SPEED 10000 RPM ± 20% at rated voltage AIR FLOW 3.0 CFM STATIC PRESSURE 0.18 Inch-H O 2 ACOUSTIC NOISE 16.0 dB(A) AIR FLOW V.S. PRESSURE See Page 5 INSULATION CLASS UL Class A 500M ohm at 500 VDC between internal stator and INSULATION RESISTANCE lead wire (+) PLASTIC HOUSING DIELECTRIC STRENGTH Applied AC 500 V for one minute or AC 600 V for 2 Seconds between housing and lead wire (+) LIFE EXPECTANCY 60,000 Hours at 40 deg. C, 65% humidity, 90% CL. Automatic Restart PROTECTION Note: In a situation where the fan is locked by an external force while the electricity is on, an increase in coil temperature will be prevented by temporarily turning off the electrical power to the motor. The fan will automatically restart when the locked rotor condition is released. Polarity Protection 4. SAFETY SAFETY UL CUR TUV NO. E77551 E77551 建 準 電 機 SUNONWEALTH 2010.06.15 Page 4 of 14 MODEL : MC25100V2-0000-A99 PERFORMANCE CURVES STATIC PRESSURE mm-H O Inch-H O 2 2 6 0.20 4 5 VDC 0.10 2 0 0 2 4 CFM 0 0.057 0.114 3 m /min 建 準 電 機 SUNONWEALTH 2010.06.15 Page 5 of 14 DIMENSIONS 建 準 電 機 SUNONWEALTH 2010.06.15 Page 6 of 14 LABEL BLACK WORD COL O R :SI LVER BLACK WORD COLOR:PANTONE 347C MC25100V2-0000-A99 GREEN BLACK WORD COLO R : SI LVER 0.43W DC5V EP DATE CODE 建 準 電 機 SUNONWEALTH 2010.06.15 Page 7 of 14 III. OTHER SPECIFIED TESTING The following is a general description of certain tests that are performed on representative Sunon fans. Nothing in this document is intended to suggest that these tests are performed on every model of Sunon fan. Moreover, the descriptions that follow each test are meant only to provide a general explanation of each test. If you would like a more detailed explanation as to any test identified in this Section, Sunon can provide such an explanation upon request. 1. DROP PROOF TEST Fans are packaged in a standard size shipping box and are dropped to the ground from certain heights and angles depending on the weight of the particular box. 2. HUMIDITY PROOF TEST The fan is operated for 96 continuous hours in an environment with humidity of 90% to 95% RH at 60°C 2°C. 3. VIBRATION PROOF TEST Vibration with an amplitude 2mm and a frequency of 5-55-5hz is applied in all 3 directions (X,Y,Z), in cycles of 1 hour each, for a total vibration time of 3hours. 4. THERMAL CYCLING TEST The fan is operated in a testing chamber for 50 cycles. In each cycle, the temperature is gradually increased from -10°C to 70°C for 90 minutes, and subsequently operated at 70°C for 120 minutes. The temperature is then gradually decreased from 70°C to -10°C for 90 minutes, and subsequently operated at -10°C for 120 minutes. 5. SHOCK PROOF TEST 100G of force is applied in the 3 directions (X,Y, and Z) for 2 milliseconds each. 6. LIFE EXPECTANCY The “Life Expectancy” of SUNON fans is determined in SUNON’s reliability test laboratory by using temperature chambers. The “Life Expectancy” of this fan has not been evaluated for use in combination with any end application. Therefore, the Life Expectancy Test Reports (L10 and MTTF Report) that relate to this fan are only for reference. 建 準 電 機 SUNONWEALTH 2010.06.15 Page 8 of 14 IV. CHARACTERISTIC DEFINITION The following is a general description of certain tests that are performed on representative Sunon fans in order to determine the specifications of the fan. Nothing in this document is intended to suggest that these tests are performed on every model of Sunon fan. Moreover, the descriptions that follow each test are meant only to provide a general explanation of each test. If you would like a more detailed explanation as to any test identified in this Section, Sunon can provide such an explanation upon request. 1. ACOUSTICAL NOISE Measured in a semi-anechoic chamber with background noise level below 15dB(A). 1 METER FROM MICROPHONE TO FAN INTAKE The fan is running in free air under shaft horizontal condition with the microphone at distance of one meter from the fan intake. 2. INPUT POWER Measured after continuous 10 minute operation at rated voltage in clean air ( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft horizontal condition. 3. RATED CURRENT Measured after continuous 10 minute operation at rated voltage in clean air ( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft horizontal condition. 建 準 電 機 SUNONWEALTH 2010.06.15 Page 9 of 14 4. RATED SPEED Measured after continuous 10 minute operation at rated voltage in clean air ( STATIC PRESSURE=0), and at ambient temperature of 25 degrees C under shaft horizontal condition. 5. STARTING VOLTAGE Measured the voltage which enables to start the fan in the clean air (static pressure = 0 ) by switching on at the voltage under shaft horizontal condition. It is not at continuously increasing voltage adjustment. 6. LOCKED ROTOR CURRENT Measured immediately after the fan blade is locked. 7. AIR FLOW AND STATIC PRESSURE The performance specification of air flow and static pressure shown in this specification for approval is measured using the exhaust method. A double chamber is used in accordance with AMCA 210 standard or DIN 24163 specification . The values are recorded when the fan speed has stabilized at rated voltage. 8. INSULATION RESISTANCE 1. PLASTIC HOUSING: (1) Measured between internal stator and lead wire(+). (2) Measured between housing and lead wire(+). 2. ALUMINIUM HOUSING: Measured between internal stator and lead wire(+). 9. DIELECTRIC STRENGTH Measure between housing and lead wire(+). 建 準 電 機 SUNONWEALTH 2010.06.15 Page 10 of 14 V. NOTE Ⅰ.SAFETY 1. DO NOT use or operate this fan in excess of the limitations set forth in this specification. SUNON is not be responsible for the non-performance of this fan and/or any damages resulting from its use, if it is not used or operated in accordance with the specifications. 2. SUNON recommends adding a protection circuit to the product or application in which this fan is installed, such as a thermo-fuse, or current-fuse or thermo-protector. The failure to use such a device may result in smoke, fire, electric shock by insulation degradation in cases of motor lead short circuit, overload, or over voltage, and/or other failure. 3. SUNON recommends installing a protection device to the product or application in which this fan is installed if there is a possibility of reverse-connection between VDC (+) and GND (-). The failure to install such a device may result in smoke, fire, and/or destruction, although these conditions may not manifest immediately. 4. This fan must be installed and used in compliance with all applicable safety standards and regulations. 5. Use proper care when handling and/or installing this fan. Improper handling or installation of this fan may cause damage that could result in unsafe conditions. 6. Use proper care during installation and/or wiring. Failure to use proper care may cause damage to certain components of the fan including, but not limited to, the coil and lead wires, which could result in smoke and/or fire. 7. DO NOT use power or ground PWM to control the fan speed. If the fan speed needs to be adjusted, please contact Sunon to customize the product design for your application. 8. For critical or extreme environments, including non stop operation, please contact Sunon and we will gladly provide assistance with your product selection to ensure an appropriate cooling product for your application. 建 準 電 機 SUNONWEALTH 2010.06.15 Page 11 of 14 II. SPECIFICATION MODIFICATION 1. SUNON offers engineering assistance on fan installation and cooling system design. 2. All changes, modifications and/or revisions to the specifications, if any, are incorporated in the attached specifications. 3. No changes, modifications and/or revisions to these specifications are effective absent agreement, by both Sunon and the customer, in writing. 4. This fan will be shipped in accordance with the attached specification unless SUNON and the customer have agreed otherwise, in writing, as specficied in Paragraph 3, above. III. OTHER 1. When building your device, please examine thoroughly any variation of EMC, temperature rise, life data, quality, etc. of this product by shock/drop/vibration testing, etc. If there are any problems or accidents in connection with this product, it should be mutually discussed and examined. 2. Use proper care when handling this fan. Components such as fan holders or bearings may be damaged, if touched with fingers or other objects. Additionally, static electricity (ESD) may damage the internal circuits of the fan. 3. DO NOT operate this fan in proximity to hazardous materials such as organic silicon, cyanogens, formalin, phenol, or corrosive gas environments including, but not limited to, H S, SO , NO , or Cl . 2 2 2 2 4. SUNON recommends that you protect this fan from exposure to outside elements such as dust, condensation, humidity or insects. Exposure of this fan to outside elements such as dust, condensation, humidity or insects may affect its performance and may cause safety hazards. SUNON does not warrant against damage to the product caused by outside elements. 建 準 電 機 SUNONWEALTH 2010.06.15 Page 12 of 14 5. This fan must be installed properly and securely. Improper mounting may cause harsh resonance, vibration, and noise. 6. Fan guards may prevent injury during handling or installation of the fan and are available for sale with this fan. 7. Unless otherwise noted, all testing of this fan is conducted at 25°C ambient temperature and sixty-five percent (65%) relative humidity. 8. DO NOT store this fan in an environment with high humidity. This fan must be stored in accordance with the attached specifications regarding storage temperature. If this fan is stored for more than 6 months, SUNON recommends functional testing before using. 9. SUNON reserves the right to use components from multiple sources at its discretion. The use of components from other sources will not affect the specfications as described herein. 10. The “Life Expectancy” of this fan has not been evaluated for use in combination with any end application. Therefore, the Life Expectancy Test Reports (L10 and MTTF Report) that relate to this fan are only for reference. VI. WARRANTY This fan is warranted against all defects which are proved to be fault in our workmanship and material for one year from the date of our delivery. The sole responsibility under the warranty shall be limited to the repair of the fan or the replacement thereof, at SUNON’s sole discretion. SUNON will not be responsible for the failures of its fans due to improper handing, misuse or the failure to follow specifications or instructions for use. In the event of warranty claim, the customer shall immediately notify SUNON for verification. SUNON will not be responsible for any consequential damage to the customer’s equipment as a result of any fans proven to be defective. 建 準 電 機 SUNONWEALTH 2010.06.15 Page 13 of 14 Declaration of RoHS Control declaration of environment-related substances/materials 1. In accordance with the Restriction of Hazardous Substances (RoHS) Directive, Sunon product have complied with law and discipline not to employ the forbidden substances, and restrict the allowable concentration of some limited substances deliberately in our components. No Substance Criteria 1 CFCs & HCFCs (ozone depleting substances) Forbidden 2 Chlorinated Organic Solvent Forbidden Plastic (Frame, Impeller, wire harness, etc.) <100ppm Solder <1000ppm 3 Lead and its compounds Steel alloy <3500ppm Aluminium alloy <4000ppm Copper alloy <4wt% Solder <20ppm Parts composed of metals containing zinc 4 Cadmium and its compounds <100ppm (e.g. brass, zinc for die casting) Plastic <5ppm 5 PBBs and PBDEs Forbidden 6 PCB and PCT Forbidden 7 CP, Short-chain Chlorinated paraffins C10-13, Cl ≥48 wt% Forbidden 8 Mirex Forbidden 9 PCN Forbidden 10 Hexavalent Chromium compounds <100ppm 11 Mercury and its compounds Forbidden 12 Asbestos Forbidden 13 Organic Tin compounds Forbidden 14 Azo compounds Forbidden 15 TBBP-A in external case plastic parts of products (PCB is exempted) <1000ppm 16 Nickel in external case parts, which are likely to result in prolonged skin exposure <1000ppm 建 準 電 機 SUNONWEALTH 2010.06.15 Page 14 of 14
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the MC25100V2-000U-A99 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods