Elite.Parts chervon right Manufacturers chervon right S chervon right STACO ENERGY PRODUCTS chervon right 6020CT-2P
About product Datasheet FAQ

STACO ENERGY PRODUCTS 6020CT-2P

Description

Staco Energy Products 6020CT-2P Transformer - VARIABLE TRANSFORMER

Part Number

6020CT-2P

Price

Request Quote

Manufacturer

STACO ENERGY PRODUCTS

Lead Time

Request Quote

Category

PRODUCTS - 6

Datasheet

pdf file

Staco Energy-6020CT-2P-datasheet1-949263445.pdf

785 KiB

Extracted Text

Variable Transformers ll Series 6000 35.0 to 315.0 Amperes 5000/6000 Series Manual Single, Uncased Two Ganged Three Ganged A 17.06” [433.3] 23.12” [587.4] B 13.56” [344.4] 19.62” [498.3] C 15.12” [384.2] 21.19” [538.2] Manual Two and Three-Ganged, Uncased Manual Single, Cased Manual Two-Ganged, Cased Single Unit Two Ganged A 12.94” [328.6] 19.18” [487.3] B 15.50” [393.7] 21.56” [547.6] Motor Driven, Single and Two-Ganged, Cased Single Unit Two Ganged Three Ganged A 13.25” [336.6] 19.32” [490.7] 25.38” [644.5] B 9.75” [247.7] 15.82” [401.8] 21.88” [555.7] C (5 sec.) 13.53” [343.7] 19.62” [498.5] 25.75” [654.0] C (15, 30 & 60 sec.) 15.12” [384.2] 21.19” [538.2] 27.25” [692.0] Motor Driven, Single,Two and Three-Ganged, Uncased 5000/6000 Series 3 Ganged 4, 5, 6 Ganged 7, 8, 9 Ganged A 35.8” [909.32] 54.8” [1391.9] 72.8” [1849.1] Manual Three to Nine-Ganged, Cased AB 4 Ganged 30.38” [771.5] 27.38” [695.3] 5 Ganged 36.44” [925.5] 33.44” [849.3] 6 Ganged 42.50” [1079.5] 39.50” [1003.3] 7 Ganged 48.56” [1233.5] 45.56” [1157.3] 8 Ganged 54.62” [1387.5] 51.62” [1311.3] 9 Ganged 60.69” [1541.5] 57.69” [1465.3] Manual Four to Nine-Ganged, Uncased 3 Ganged 4, 5, 6 Ganged 7, 8, 9 Ganged A 33.5” [850.9] 52.5” [1333.5] 70.5” [1061.9] Motor-Driven Three to Nine-Ganged, Cased 5021-3Y 10 & 12 Ganged 14, 16 & 18 Ganged A 52.5” [1333.5] 70.5” [1790.7] Motor-Driven 10, 12, 14, 16 & 18-Ganged Open Delta and Parallel, Cased 5000/6000 Series 12 Ganged 15 Ganged 18 Ganged 21 Ganged 24 Ganged 27 Ganged A 36.31” [922.3] 42.38” [1076.4] 48.44” [1230.3] 54.50” [1384.3] 60.56” [1538.3] 66.62” [1692.3] B 30.94” [786.8] 37.00” [939.8] 43.06” [1093.8] 49.12” [1247.8] 55.19” [1401.8] 61.25” [1555.8] Motor-Driven 12, 15, 18, 21, 24 & 27-Ganged, Uncased 12, 15, 18 Ganged 21, 24, 27 Ganged A 52.5” [1333.5] 70.5” [1790.7] Motor-Driven 12, 15, 18, 21, 24 & 27-Ganged, Cased 10 Ganged 12 Ganged 14 Ganged 16 Ganged 18 Ganged 60M5021-27Y A 42.38” [1076.3] 48.44” [1230.3] 54.50” [1384.3] 60.56” [1538.3] 66.62” [1692.3] B 37.00” [939.8] 43.06” [1093.8] 49.12” [1247.8] 55.19” [1401.8] 61.25” [1555.8] Motor-Driven 10, 12, 14, 16 & 18-Ganged Open Delta & Parallel, Uncased 6000 Series Variable transformers of the 6011/6020 Series are designed housing to accomodate conduit or cable connections. For three ganged and above, we offer our Nema 1, dripproof, fully front for larger KVA requirements. The 6011, 120 volt unit is rated accessible “E” enclosure. for constant current of 60 amperes. The 6020, 240 volt unit is rated at 35 amperes for constant current loads. All single Motor-driven models are available from single thru 27 units have coil tapping arrangements allowing output voltage ganged assemblies; cased or uncased (identified with the from 0 to line voltage or 17% above line voltage. prefix “M” in the part number. The synchronous motor is Adjustable shaft design on manually operated models permits designed for operation on 120 volt, 50/60 Hertz lines and back-of-panel or bench mounting. Terminals are 1/4” screw draws approximately 0.3 amperes. To meet a wide range of type. For single and two ganged units, case styles are available application requirements, standard motor speeds of 5, 15, in either “C” style, which encloses only the coil, or the “CT” 30 and 60 seconds are available depending upon the size of style, which provides protective housing for both the coil and terminal board. Knockouts are provided in the terminal board the variable transformer. PART NUMBER INPUT OUTPUT SHAFT TERMINAL CONNECTIONS NET WEIGHT ROTATION For Increasing Voltage IN LBS. WIRING FOR As Viewed from Rotor End SCHE- (MAX) MANUALLY MOTOR VOLTS HERTZ VOLTS MAX MAX VOLTAGE MATIC MAN- MOTOR OPERATED DRIVEN AMPS KVA INCREASE INPUT OUTPUT (Pg 8 & 9) UAL DRIVEN CW 2-4 2-3 6011 M6011 0-120 60 7.2 Single CCW 4-2 4-3 6011C M6011C 120 50/60 19 67 88 Phase CW 2-5 2-3 6011CT M6011CT 0-140 60 8.4 CCW 4-1 4-3 CW 2-4 2-3 0-240 35 8.4 CCW 4-2 4-3 6020 M6020 240 50/60 Single CW 2-5 2-3 6020C M6020C 0-280 35 9.8 19 63 84 Phase CCW 4-1 4-3 6020CT M6020CT 35*-15 CW 2-6 2-3 120 50/60 0-280 4.2‡ V. D. CCW 4-7 4-3 Three 6011-2D M6011-2D 0-120 60 12.5 CW 4-1-4 3-1-3 Phase 6011C-2D M6011C-2D 120 50/60 20 & 5 154 175 Open 6011CT-2D M6011CT-2D 0-140 60 14.5 CW 2-1-2 3-1-3 Delta 6011-2P M6011-2P Single 0-120 120 14.4 CW 1-4 1-B 6011C-2P M6011C-2P Phase 120 50/60 21 156 177 0-140 120 16.8 CW 1-2 1-B 6011CT-2P M6011CT-2P Parallel 6011-2S M6011-2S Single 0-240 60 14.4 CW 4-4 3-3 6011C-2S M6011C-2S Phase 240 50/60 20 & 4 154 175 0-280 60 16.8 CW 2-2 3-3 6011CT-2S M6011CT-2S Series Three 0-240 35 14.5 CW 4-1-4 3-1-3 6020-2D M6020-2D 240 50/60 Phase 0-280 35 16.9 CW 2-1-2 3-1-3 6020C-2D M6020C-2D 20 & 5 146 167 Open 35*-15 6020CT-2D M6020CT-2D 120 50/60 0-280 7.3‡ CW 5-1-5 3-1-3 Delta V. D. 0-240 70 16.8 CW 1-4 1-B 6020-2P M6020-2P Single 240 50/60 0-280 70 19.6 CW 1-2 1-B 6020C-2P M6020C-2P Phase 21 148 169 70*-30 6020CT-2P M6020CT-2P Parallel 120 50/60 0-280 8.4‡ CW 1-5 1-B V. D. 0-480 35 16.8 CW 4-4 3-3 6020-2S M6020-2S Single 480 50/60 0-560 35 19.6 CW 2-2 3-3 6020C-2S M6020C-2S Phase 20 & 4 146 167 35*-15 6020CT-2S M6020CT-2S Series 240 50/60 0-560 8.4‡ CW 5-5 3-3 V. D. Single 0-120 180 21.6 CW 1-4 1-D 6011-3P M6011-3P Phase 120 50/60 22 246 267 6011E-3P M6011E-3P 0-140 180 25.2 CW 1-2 1-D Parallel Three 0-240 60 24.9 CW 4-4-4 3-3-3 6011-3Y M6011-3Y Phase 240 60 20 & 6 242 263 6011E-3Y M6011E-3Y 0-280 60 29.1 CW 2-2-2 3-3-3 Wye 6011 6020 6011 6000 Series VIEW FROM ROTOR END For opposite rotation interchange external connections from 5 to 1, 2 to 4 and 6 to 7. 6011 Single Unit 6011 Ganged Unit 6020 Single Unit 6020 Ganged Unit PART NUMBER INPUT OUTPUT SHAFT TERMINAL CONNECTIONS NET WEIGHT ROTATION For Increasing Voltage IN LBS. WIRING FOR As Viewed from Rotor End SCHE- (MAX) MANUALLY MOTOR VOLTS HERTZ VOLTS MAX MAX VOLTAGE MATIC MAN- MOTOR OPERATED DRIVEN AMPS KVA INCREASE INPUT OUTPUT (Pg 8 & 9) UAL DRIVEN 0-240 105 25.2 CW 1-4 1-D Single 240 50/60 6020-3P M6020-3P 0-280 105 29.4 CW 1-2 1-D Phase 22 246 267 6020E-3P M6020E-3P 105*-45 Parallel 120 50/60 0-280 12.6‡ CW 1-5 1-D V. D. 50/60 0-480 35 29.1 CW 4-4-4 3-3-3 Three 480 6020-3Y M6020-3Y 60 0-560 35 33.9 CW 2-2-2 3-3-3 Phase 20 & 6 240 261 6020E-3Y M6020E-3Y 35*-15 Wye 240 60 0-560 14.5‡ CW 5-5-5 3-3-3 V. D. Three 0-120 120 24.9 CW 4-1-4 B-1-B 6011-4D M6011-4D Phase 120 50/60 21 & 5 354 375 6011E-4D M6011E-4D Open 0-140 120 29.1 CW 2-1-2 B-1-B Delta Single 0-120 240 28.8 CW 1-4 1-D 6011-4P M6011-4P Phase 120 50/60 22 356 377 6011E-4P M6011E-4P 0-140 240 33.6 CW 1-2 1-D Parallel Single 0-240 120 28.8 CW 4-4 B-B 6011-4PS M6011-4PS Phase 240 50/60 21 & 4 354 375 6011E-4PS M6011E-4PS Series 0-280 120 33.6 CW 2-2 B-B Parallel Three 0-240 70 29.1 CW 4-1-4 B-1-B 240 50/60 6020-4D M6020-4D Phase 0-280 70 33.9 CW 2-1-2 B-1-B 21 & 5 338 359 6020E-4D M6020E-4D Open 70*-30 120 50/60 0-280 14.5‡ CW 5-1-5 B-1-B Delta V. D. 0-240 140 33.6 CW 1-4 1-D Single 240 50/60 6020-4P M6020-4P 0-280 140 39.2 CW 1-2 1-D Phase 22 340 361 6020E-4P M6020E-4P 140*-60 Parallel 120 50/60 0-280 16.8‡ CW 1-5 1-D V. D. Single 0-480 70 33.6 CW 4-4 B-B 480 50/60 6020-4PS M6020-4PS Phase 0-560 70 39.2 CW 2-2 B-B 21 & 4 338 359 6020E-4PS M6020E-4PS Series 70*-30 240 50/60 0-560 16.8‡ CW 5-5 B-B Parallel V. D. Single 0-120 300 36.0 CW 1-4 1-D 6011-5P M6011-5P Phase 120 50/60 22 450 471 6011E-5P M6011E-5P 0-140 300 42.0 CW 1-2 1-D Parallel 0-240 175 42.0 CW 1-4 1-D Single 240 50/60 6020-5P M6020-5P 0-280 175 49.0 CW 1-2 1-D Phase 22 430 451 6020E-5P M6020E-5P 175*-75 Parallel 120 50/60 0-280 21.0‡ CW 1-5 1-D V. D. Three 0-120 180 37.4 CW 4-1-4 D-1-D 6011-6D M6011-6D Phase 120 50/60 22 & 5 541 562 6011E-6D M6011E-6D Open 0-140 180 43.6 CW 2-1-2 D-1-D Delta Single 0-120 360 43.2 CW 1-4 1-D 6011-6P M6011-6P Phase 120 50/60 22 543 564 6011E-6P M6011E-6P 0-140 360 50.4 CW 1-2 1-D Parallel Single 0-240 180 43.2 CW 4-4 D-D 6011-6PS M6011-6PS Phase 240 50/60 22 & 4 541 562 6011E-6PS M6011E-6PS Series 0-280 180 50.4 CW 2-2 D-D Parallel Three 0-240 120 49.8 CW 4-4-4 B-B-B 6011-6Y M6011-6Y Phase 240 60 21 & 6 539 560 6011E-6Y M6011E-6Y 0-280 120 58.1 CW 2-2-2 B-B-B Wye 6000 Series PART NUMBER INPUT OUTPUT SHAFT TERMINAL CONNECTIONS NET WEIGHT ROTATION For Increasing Voltage IN LBS. WIRING FOR As Viewed from Rotor End SCHE- (MAX) MANUALLY MOTOR VOLTS HERTZ VOLTS MAX MAX VOLTAGE MATIC MAN- MOTOR OPERATED DRIVEN AMPS KVA INCREASE INPUT OUTPUT (Pg 8 & 9) UAL DRIVEN Three 0-240 105 43.6 CW 4-1-4 D-1-D 240 50/60 6020-6D M6020-6D Phase 0-280 105 50.9 CW 2-1-2 D-1-D 22 & 5 517 538 6020E-6D M6020E-6D Open 105*-45 120 50/60 0-280 21.8‡ CW 5-1-5 D-1-D Delta V. D. 0-240 210 50.4 CW 1-4 1-D Single 240 50/60 6020-6P M6020-6P 0-280 210 58.8 CW 1-2 1-D Phase 22 489 510 6020E-6P M6020E-6P 210*-90 Parallel 25.2‡ CW 1-5 1-D 120 50/60 0-280 V. D. Single 0-480 105 50.4 CW 4-4 D-D 480 50/60 6020-6PS M6020-6PS Phase 0-560 105 58.8 CW 2-2 D-D 22 & 4 487 508 6020E-6PS M6020E-6PS Series 105*-45 240 50/60 0-560 25.2‡ CW 5-5 D-D Parallel V. D. 50/60 0-480 70 58.1 CW 4-4-4 B-B-B Three 480 6020-6Y M6020-6Y 60 0-560 70 67.8 CW 2-2-2 B-B-B Phase 21 & 6 485 506 6020E-6Y M6020E-6Y 70*-30 Wye 240 60 0-560 29.1‡ CW 5-5-5 B-B-B V. D. Single 0-120 420 50.4 CW 1-4 1-D 6011-7P M6011-7P Phase 120 50/60 22 633 654 6011E-7P M6011E-7P 0-140 420 58.8 CW 1-2 1-D Parallel 0-240 245 58.8 CW 1-4 1-D Single 240 50/60 6020-7P M6020-7P 0-280 245 68.6 CW 1-2 1-D Phase 22 598 619 6020E-7P M6020E-7P 245*-105 Parallel 120 50/60 0-280 29.4‡ CW 1-5 1-D V. D. Three 0-120 240 49.8 CW 4-1-4 D-1-D 6011-8D M6011-8D Phase 120 50/60 22 & 5 720 741 6011E-8D M6011E-8D Open 0-140 240 58.1 CW 2-1-2 D-1-D Delta Single 0-120 480 57.6 CW 1-4 1-D 6011-8P M6011-8P Phase 120 50/60 22 722 743 6011E-8P M6011E-8P 0-140 480 67.2 CW 1-2 1-D Parallel Single 0-240 240 57.6 CW 4-4 D-D 6011-8PS M6011-8PS Phase 240 50/60 22 & 4 720 741 6011E-8PS M6011E-8PS Series 0-280 240 67.2 CW 2-2 D-D Parallel Three 0-240 140 58.1 CW 4-1-4 D-1-D 240 50/60 6020-8D M6020-8D Phase 0-280 140 67.8 CW 2-1-2 D-1-D 22 & 5 688 709 6020E-8D M6020E-8D Open 140*-60 120 50/60 0-280 29.1‡ CW 5-1-5 D-1-D Delta V. D. 0-240 280 67.2 CW 1-4 1-D Single 240 50/60 6020-8P M6020-8P 0-280 280 78.4 CW 1-2 1-D Phase 22 690 711 6020E-8P M6020E-8P 280*-120 Parallel 120 50/60 0-280 33.6‡ CW 1-5 1-D V. D. Single 0-480 140 67.2 CW 4-4 D-D 480 50/60 6020-8PS M6020-8PS Phase 0-560 140 78.4 CW 2-2 D-D 22 & 4 688 709 6020E-8PS M6020E-8PS Series 140*-60 240 50/60 0-560 33.6‡ CW 5-5 D-D Parallel V. D. Single 0-120 540 64.8 CW 1-4 1-D 6011-9P M6011-9P Phase 120 50/60 22 811 832 6011E-9P M6011E-9P 0-140 540 75.6 CW 1-2 1-D Parallel Three 0-240 180 74.7 CW 4-4-4 D-D-D 6011-9Y M6011-9Y Phase 240 60 22 & 6 807 828 6011E-9Y M6011E-9Y 0-280 180 87.2 CW 2-2-2 D-D-D Wye 0-240 315 75.6 CW 1-4 1-D Single 240 50/60 6020-9P M6020-9P 0-280 315 88.2 CW 1-2 1-D Phase 22 775 796 6020E-9P M6020E-9P 315*-135 Parallel 120 50/60 0-280 37.8‡ CW 1-5 1-D V. D. 50/60 0-480 105 87.2 CW 4-4-4 D-D-D Three 480 6020-9Y M6020-9Y 60 0-560 105 101.7 CW 2-2-2 D-D-D Phase 22 & 6 771 792 6020E-9Y M6020E-9Y 105*-45 Wye 240 60 0-560 43.6‡ CW 5-5-5 D-D-D V. D. Three 0-120 300 62.3 CW 4-1-4 D-1-D M6011-10D Phase — 120 50/60 22 & 5 — 912 M6011E-10D Open 0-140 300 72.7 CW 2-1-2 D-1-D Delta Single 0-240 300 72.0 CW 4-4 D-D M6011-10PS Phase — 240 50/60 22 & 4 — 912 M6011E-10PS Series 0-280 300 84.0 CW 2-2 D-D Parallel Three 0-240 175 72.7 CW 4-1-4 D-1-D 240 50/60 M6020-10D Phase 0-280 175 84.8 CW 2-1-2 D-1-D — 22 & 5 — 912 M6020E-10D Open 175*-75 120 50/60 0-280 36.3‡ CW 5-1-5 D-1-D Delta V. D. 6000 Series PART NUMBER INPUT OUTPUT SHAFT TERMINAL CONNECTIONS NET WEIGHT ROTATION For Increasing Voltage IN LBS. WIRING FOR As Viewed from Rotor End SCHE- (MAX) MANUALLY MOTOR VOLTS HERTZ VOLTS MAX MAX VOLTAGE MATIC MAN- MOTOR OPERATED DRIVEN AMPS KVA INCREASE INPUT OUTPUT (Pg 8 & 9) UAL DRIVEN Single 0-480 175 84.0 CW 4-4 D-D 480 50/60 M6020-10PS Phase 0-560 175 98.0 CW 2-2 D-D — 22 & 4 — 872 M6020E-10PS Series 175*-75 240 50/60 0-560 42.0‡ CW 5-5 D-D Parallel V. D. Three 0-120 360 74.7 CW 4-1-4 D-1-D M6011-12D Phase — 120 50/60 22 & 5 — 1060 M6011E-12D Open 0-140 360 87.2 CW 2-1-2 D-1-D Delta Single 0-240 360 86.4 CW 4-4 D-D M6011-12PS Phase — 240 50/60 22 & 4 — 1060 M6011E-12PS Series 0-280 360 100.8 CW 2-2 D-D Parallel Three 0-240 210 87.2 CW 4-1-4 D-1-D 240 50/60 M6020-12D Phase 0-280 210 101.7 CW 2-1-2 D-1-D — 22 & 5 — 1012 M6020E-12D Open 210*-90 120 50/60 0-280 43.6‡ CW 5-1-5 D-1-D Delta V. D. Single 0-480 210 100.8 CW 4-4 D-D 480 50/60 M6020-12PS Phase 0-560 210 117.6 CW 2-2 D-D 22 & 4 — 1012 — M6020E-12PS Series 210*-90 240 50/60 0-560 50.4‡ CW 5-5 D-D Parallel V. D. Three 0-120 420 87.2 CW 4-1-4 D-1-D M6011-14D Phase — 120 50/60 22 & 5 — 1237 M6011E-14D Open 0-140 420 101.7 CW 2-1-2 D-1-D Delta Single 0-240 420 100.8 CW 4-4 D-D M6011-14PS Phase — 240 50/60 22 & 4 — 1237 M6011E-14PS Series 0-280 420 117.6 CW 2-2 D-D Parallel Three 0-240 245 101.7 CW 4-1-4 D-1-D 240 50/60 M6020-14D Phase 0-280 245 118.7 CW 2-1-2 D-1-D — 22 & 5 — 1181 M6020E-14D Open 245*-105 120 50/60 0-280 50.9‡ CW 5-1-5 D-1-D Delta V. D. Single 0-480 245 117.6 CW 4-4 D-D 480 50/60 M6020-14PS Phase 0-560 245 137.2 CW 2-2 D-D — 22 & 4 — 1181 M6020E-14PS Series 245*-105 240 50/60 0-560 58.8‡ CW 5-5 D-D Parallel V. D. Three 0-120 480 99.6 CW 4-1-4 D-1-D M6011-16D Phase — 120 50/60 22 & 5 — 1414 M6011E-16D Open 0-140 480 116.3 CW 2-1-2 D-1-D Delta Single 0-240 480 115.2 CW 4-4 D-D M6011-16PS Phase — 240 50/60 22 & 4 — 1414 M6011E-16PS Series 0-280 480 134.4 CW 2-2 D-D Parallel Three 0-240 280 116.3 CW 4-1-4 D-1-D 240 50/60 M6020-16D Phase 0-280 280 135.6 CW 2-1-2 D-1-D — 22 & 5 — 1350 M6020E-16D Open 280*-120 120 50/60 0-280 58.1‡ CW 5-1-5 D-1-D Delta V. D. Single 0-480 280 134.4 CW 4-4 D-D 480 50/60 M6020-16PS Phase 0-560 280 156.8 CW 2-2 D-D — 22 & 4 — 1350 M6020E-16PS Series 280*-120 240 50/60 0-560 67.2‡ CW 5-5 D-D Parallel V. D. Three 0-120 540 112.1 CW 4-1-4 D-1-D M6011-18D Phase — 120 50/60 22 & 5 — 1597 M6011E-18D Open 0-140 540 130.8 CW 2-1-2 D-1-D Delta Single 0-240 540 129.6 CW 4-4 D-D M6011-18PS Phase — 240 50/60 22 & 4 — 1597 M6011E-18PS Series 0-280 540 151.2 CW 2-2 D-D Parallel Three 0-240 315 130.8 CW 4-1-4 D-1-D 240 50/60 M6020-18D Phase 0-280 315 152.6 CW 2-1-2 D-1-D — 22 & 5 — 1525 M6020E-18D Open 315*-135 120 50/60 0-280 94.5‡ CW 5-1-5 D-1-D Delta V. D. Single 0-480 315 151.2 CW 4-4 D-D 480 50/60 M6020-18PS Phase 0-560 315 176.4 CW 2-2 D-D — 22 & 4 — 1525 M6020E-18PS Series 315*-135 240 50/60 0-560 75.6‡ CW 5-5 D-D Parallel V. D. Three 0-240 240 99.6 CW 4-4-4 D-D-D M6011-12Y — Phase 240 60 22 & 6 — 1062 M6011E-12Y Wye 0-280 240 116.3 CW 2-2-2 D-D-D 6000 Series PART NUMBER INPUT OUTPUT SHAFT TERMINAL CONNECTIONS NET WEIGHT ROTATION For Increasing Voltage IN LBS. WIRING FOR As Viewed from Rotor End SCHE- (MAX) MANUALLY MOTOR VOLTS HERTZ VOLTS MAX MAX VOLTAGE MATIC MAN- MOTOR OPERATED DRIVEN AMPS KVA INCREASE INPUT OUTPUT (Pg 8 & 9) UAL DRIVEN 50/60 0-480 140 116.3 CW 4-4-4 D-D-D Three 480 M6020-12Y 60 0-560 140 135.6 CW 2-2-2 D-D-D — Phase 22 & 6 — 1014 M6020E-12Y 140*-60 Wye 240 60 0-560 58.1‡ CW 5-5-5 D-D-D V. D. Three 0-240 300 124.6 CW 4-4-4 D-D-D M6011-15Y — Phase 240 60 22 & 6 — 1329 M6011E-15Y 0-280 300 145.3 CW 2-2-2 D-D-D Wye 50/60 0-480 175 145.3 CW 4-4-4 D-D-D Three 480 M6020-15Y 60 0-560 175 169.5 CW 2-2-2 D-D-D — Phase 22 & 6 — 1269 M6020E-15Y 175*-75 Wye 240 60 0-560 72.7‡ CW 5-5-5 D-D-D V. D. Three 0-240 360 149.5 CW 4-4-4 D-D-D M6011-18Y — Phase 240 60 22 & 6 — 1595 M6011E-18Y 0-280 360 174.4 CW 2-2-2 D-D-D Wye 50/60 0-480 210 174.6 CW 4-4-4 D-D-D Three 480 M6020-18Y 60 0-560 210 203.4 CW 2-2-2 D-D-D — Phase 22 & 6 — 1523 M6020E-18Y 210*-90 Wye 240 60 0-560 87.2‡ CW 5-5-5 D-D-D V. D. Three 0-240 420 174.4 CW 4-4-4 D-D-D M6011-21Y — Phase 240 60 22 & 6 — 1864 M6011E-21Y 0-280 420 203.4 CW 2-2-2 D-D-D Wye 50/60 0-480 245 203.4 CW 4-4-4 D-D-D Three 480 M6020-21Y 60 0-560 245 237.4 CW 2-2-2 D-D-D — Phase 22 & 6 — 1780 M6020E-21Y 245*-105 Wye 240 60 0-560 101.7‡ CW 5-5-5 D-D-D V. D. Three 0-240 480 199.3 CW 4-4-4 D-D-D M6011-24Y — Phase 240 60 22 & 6 — 2132 M6011E-24Y 0-280 480 232.5 CW 2-2-2 D-D-D Wye 50/60 0-480 280 232.5 CW 4-4-4 D-D-D Three 480 M6020-24Y 60 0-560 280 271.3 CW 2-2-2 D-D-D — Phase 22 & 6 — 2036 M6020E-24Y 280*-120 Wye 240 60 0-560 116.3‡ CW 5-5-5 D-D-D V. D. Three 0-240 540 224.2 CW 4-4-4 D-D-D M6011-27Y — Phase 240 60 22 & 6 — 2401 M6011E-27Y 0-280 540 261.6 CW 2-2-2 D-D-D Wye 50/60 0-480 315 261.6 CW 4-4-4 D-D-D 480 M6020-27Y Three 60 0-560 315 305.2 CW 2-2-2 D-D-D — 22 & 6 — 2293 M6020E-27Y Phase 315*-135 240 60 0-560 130.8‡ CW 5-5-5 D-D-D Wye V. D. * Maximum output current in output voltage range from 0 to 25 percent above line voltage. At higher output voltages, output current must be reduced according to rating curve Figure B, page 6. ‡ Maximum KVA at maximum output and corresponding de-rated current. Maximum KVA at lower output voltages may be calculated from rating curve Figure B, page 6. V. D. Voltage Doubler

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 6020CT-2P have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Variable Transformer Voltage Controls 120V 60A

VARIABLE TRANSFORMER

VARIABLE TRANSFORMER

VARIABLE TRANSFORMER

VARIABLE TRANSFORMER

Transformer; Three Phase Wye Wiring; 240 V @ 60 Hz; 60 A; 0 to 240, 0 to 280 V