Staco Energy Products 5021E-4P Manually Operated Variable Transformer, single phase wiring, input 120 volts, 50/60 hertz, outout 0-280 volts, 56*-24V.D. max Amps, 11.8 max KVA, shaft rotation for voltage increase CW, terminal connections input 1-5, output 1-D, schematic 22 & net weight 337lbs.

Part Number

5021E-4P

Price

Request Quote

Manufacturer

STACO ENERGY PRODUCTS

Lead Time

Request Quote

Category

PRODUCTS - 5

Datasheet

pdf file

Staco-Energy-Products-Variable-Transformers-5000-Series-datasheet1-1630460080.pdf

1105 KiB

Extracted Text

Variable Transformers ll Series 5000 28.0 to 252.0 Amperes 5000 Series The 5011/5021 Series Variable transformers are designed to which provides protective housing for both the coil and terminal control large KVA requirements. The 5011 operates on 120 board. Knockouts are provided in the terminal board housing to volts and is rated for constant current of 50 amperes. The 5021 accomodate conduit or cable connections. For three ganged operates on 240 volts and constant current of 28 amperes. The and above, we offer our Nema 1, dripproof, fully front accessi- 5011 Series units have coil tapping arrangements allowing out- ble “E” enclosure. put voltage from 0-117% of line voltage, while the 5021 Series Motor-driven models are available from single thru 27 ganged allows output voltage from 0 to line voltage or 17% above line assemblies; cased or uncased (identified with the prefix “M” in voltage. They can be operated at frequencies between 50 and the part number). The synchronous motor is designed for 400 Hertz with a rating at higher than rated frequency. operation on 120 volt, 50/60 Hertz, single phase lines and draws approximately 0.3 amperes. To meet a wide range of Adjustable shaft design on manually operated models permits application requirements, standard motor speeds of 5, 15, 30 back-of-panel or bench mounting. Terminals are 1/4” screw type. For single and two ganged units, case styles are available and 60 seconds are available depending upon the size of the in either “C” style, which encloses only the coil, or the “CT” style, variable transformer. PART NUMBER INPUT OUTPUT SHAFT TERMINAL CONNECTIONS NET WEIGHT ROTATION For Increasing Voltage IN LBS. FOR As Viewed from Rotor End SCHE- (MAX) WIRING MANUALLY MOTOR MAX MAX VOLTAGE MATIC VOLTS HERTZ VOLTS MAN- MOTOR OPERATED DRIVEN AMPS KVA INCREASE INPUT OUTPUT (Pg 8 & 9) UAL DRIVEN 5011 M5011 Single 5011C M5011C 120 50/60 0-140 50 7.0 CW 1-2 1-3 18 57 78 Phase 5011CT M5011CT CW 2-4 2-3 0-240 28 6.7 CCW 4-2 4-3 5021 M5021 240 50/60 Single CW 2-5 2-3 5021C M5021C 0-280 28 7.8 19 57 78 Phase CCW 4-1 4-3 5021CT M5021CT 28*-12 CW 2-6 2-3 120 50/60 0-280 3.4‡ VD CCW 4-7 4-3 5011-2D M5011-2D Three 5011C-2D M5011C-2D Phase 120 50/60 0-140 50 12.1 CW 2-1-2 3-1-3 20 & 5 134 155 5011CT-2D M5011CT-2D Open Delta 5011-2P M5011-2P Single 5011C-2P M5011C-2P Phase 120 50/60 0-140 100 14.0 CW 1-2 1-B 21 136 157 5011CT-2P M5011CT-2P Parallel 5011-2S M5011-2S Single 5011C-2S M5011C-2S Phase 240 50/60 0-280 50 14.0 CW 2-2 3-3 20 & 4 134 155 5011CT-2S M5011CT-2S Series 0-240 28 11.6 CW 4-1-4 3-1-3 5021-2D M5021-2D Three 240 50/60 0-280 28 13.6 CW 2-1-2 3-1-3 5021C-2D M5021C-2D Phase 20 & 5 134 155 28*-12 5.8‡ 5021CT-2D M5021CT-2D Open Delta 120 50/60 0-280 CW 5-1-5 3-1-3 V.D. 0-240 56 13.4 CW 1-4 1-B 5021-2P M5021-2P Single 240 50/60 0-280 56 15.7 CW 1-2 1-B 5021C-2P M5021C-2P Phase 21 136 157 56*-24 5021CT-2P M5021CT-2P Parallel 120 50/60 0-280 6.8‡ CW 1-5 1-B V.D. 0-480 28 13.5 CW 4-4 3-3 5021-2S M5021-2S Single 480 50/60 0-560 28 15.7 CW 2-2 3-3 5021C-2S M5021C-2S Phase 20 & 4 134 155 28*-12 5021CT-2S M5021CT-2S Series 240 50/60 0-560 6.8‡ CW 5-5 3-3 V.D. Single 5011-3P M5011-3P Phase 120 50/60 0-140 150 21.0 CW 1-2 1-D 22 216 237 5011E-3P M5011E-3P Parallel Three 5011-3Y M5011-3Y Phase 240 60 0-280 50 24.2 CW 2-2-2 3-3-3 20 & 6 212 233 5011E-3Y M5011E-3Y Wye 5011C 5021 5021CT-2 5011 5000 Series VIEW FROM ROTOR END For opposite rotation interchange external connections from 5 to 1, 2 to 4 and 6 to 7. 5011 5021 Single Unit 5021 Ganged Unit PART NUMBER INPUT OUTPUT SHAFT TERMINAL CONNECTIONS NET WEIGHT ROTATION For Increasing Voltage IN LBS. FOR As Viewed from Rotor End SCHE- (MAX) WIRING MANUALLY MOTOR MAX MAX VOLTAGE MATIC VOLTS HERTZ VOLTS MAN- MOTOR OPERATED DRIVEN AMPS KVA INCREASE INPUT OUTPUT (Pg 8 & 9) UAL DRIVEN 0-240 84 20.2 CW 1-4 1-D Single 240 50/60 5021-3P M5021-3P 0-280 84 23.5 CW 1-2 1-D Phase 22 216 237 5021E-3P M5021E-3P 84*-36 10.2‡ Parallel 120 50/60 0-280 CW 1-5 1-D V. D. 50/60 0-480 28 23..3 CW 4-4-4 3-3-3 Three 480 5021-3Y M5021-3Y 60 0-560 28 27.2 CW 2-2-2 3-3-3 Phase 20 & 6 212 233 5021E-3Y M5021E-3Y 28*-12 Wye 240 60 0-560 11.8‡ CW 5-5-5 3-3-3 V. D. Three 5011-4D M5011-4D Phase 120 50/60 0-140 100 24.2 CW 2-1-2 B-1-B 21 & 5 314 335 5011E-4D M5011E-4D Open Delta Single 5011-4P M5011-4P Phase 120 50/60 0-140 200 28.0 CW 1-2 1-D 22 316 337 5011E-4P M5011E-4P Parallel Single 5011-4PS M5011-4PS Phase 240 50/60 0-280 100 28.0 CW 2-2 B-B 21 & 4 314 335 5011E-4PS M5011E-4PS Series Parallel 0-240 56 23.3 CW 4-1-4 B-1-B Three 240 50/60 5021-4D M5021-4D 0-280 56 27.2 CW 2-1-2 B-1-B Phase 21 & 5 314 335 5021E-4D M5021E-4D 56*-24 Open Delta 120 50/60 0-280 11.8‡ CW 5-1-5 B-1-B V. D. 0-240 112 26.9 CW 1-4 1-D Single 240 50/60 5021-4P M5021-4P 0-280 112 31.4 CW 1-2 1-D Phase 22 316 337 5021E-4P M5021E-4P 112*-48 Parallel 120 50/60 0-280 CW 1-5 1-D 13.5‡ V.D. 0-480 56 26.9 CW 4-4 B-B Single 480 50/60 5021-4PS M5021-4PS 0-560 56 31.4 CW 2-2 B-B Phase 21 & 4 314 335 5021E-4PS M5021E-PS 56*-24 Series 240 50/60 0-560 13.5‡ CW 5-5 B-B V. D. Single 5011-5P M5011-5P Phase 120 50/60 0-140 250 35.0 CW 1-2 1-D 22 400 420 5011E-5P M5011E-5P Parallel Three 5011-6D M5011-6D Phase 120 50/60 0-140 150 36.4 CW 2-1-2 D-1-D 22 & 5 481 502 5011E-6D M5011E-6D Open Delta Single 5011-6P M5011-6P Phase 120 50/60 0-140 300 42.0 CW 1-2 1-D 22 483 504 5011E-6P M5011E-6P Parallel Single 5011-6PS M5011-6PS Phase 240 50/60 0-280 150 42.0 CW 2-2 D-D 22 & 4 481 502 5011E-6PS M5011E-6PS Series Parallel Three 5011-6Y M5011-6Y Phase 240 60 0-280 100 48.5 CW 2-2-2 B-B-B 21 & 6 479 500 5011E-6Y M5011E-6Y Wye 5000 Series PART NUMBER INPUT OUTPUT SHAFT TERMINAL CONNECTIONS NET WEIGHT ROTATION For Increasing Voltage IN LBS. WIRING FOR As Viewed from Rotor End SCHE- (MAX) MANUALLY MOTOR VOLTS HERTZ VOLTS MAX MAX VOLTAGE MATIC MAN- MOTOR OPERATED DRIVEN AMPS KVA INCREASE INPUT OUTPUT (Pg 8 & 9) UAL DRIVEN 0-240 84 34.9 CW 4-1-4 D-1-D Three 240 50/60 5021-6D M5021-6D 0-280 84 40.7 CW 2-1-2 D-1-D Phase 22 & 5 481 502 5021E-6D M5021E-6D 84*-36 Open Delta 120 50/60 0-280 17.6‡ CW 5-1-5 D-1-D V. D. 0-240 168 40.3 CW 1-4 1-D Single 240 50/60 5021-6P M5021-6P 0-280 168 47.0 CW 1-2 1-D Phase 22 483 504 5021E-6P M5021E-6P 168*-72 Parallel 120 50/60 0-280 20.4‡ CW 1-5 1-D V. D. Single 0-480 84 40.3 CW 4-4 D-D 480 50/60 5021-6PS M5021-6PS Phase 0-560 84 47.0 CW 2-2 D-D 22 & 4 481 502 5021E-6PS M5021E-6PS Series 84*-36 240 50/60 0-560 20.4‡ CW 5-5 D-D Parallel V. D. 50/60 0-480 56 46.6 CW 4-4-4 B-B-B Three 480 5021-6Y M5021-6Y 60 0-560 56 54.3 CW 2-2-2 B-B-B Phase 21 & 6 479 500 5021E-6Y M5021E-6Y 56*-24 Wye 240 60 0-560 23.5‡ CW 5-5-5 B-B-B V. D. Single 5011-7P M5011-7P Phase 120 50/60 0-140 350 49.0 CW 1-2 1-D 22 563 584 5011E-7P M5011E-7P Parallel 0-240 196 47.0 CW 1-4 1-D Single 240 50/60 5021-7P M5021-7P 0-280 196 54.9 CW 1-2 1-D Phase 22 563 584 5021E-7P M5021E-7P 196*-84 Parallel 120 50/60 0-280 23.5‡ CW 1-5 1-D V. D. Three 5011-8D M5011-8D Phase 120 50/60 0-140 200 48.4 CW 2-1-2 D-1-D 22 & 5 640 661 5011E-8D M5011E-8D Open Delta Single 5011-8P M5011-8P Phase 120 50/60 0-140 400 56.0 CW 1-2 1-D 22 642 663 5011E-8P M5011E-8P Parallel Single 5011-8PS M5011-8PS Phase 240 50/60 0-280 200 56.0 CW 2-2 D-D 22 & 4 640 661 5011E-8PS M5011E-8PS Series Parallel 0-240 112 46.6 CW 4-1-4 D-1-D Three 240 50/60 5021-8D M5021-8D 0-280 112 54.3 CW 2-1-2 D-1-D Phase 22 & 5 640 661 5021E-8D M5021E-8D 112*-48 Open Delta 120 50/60 0-280 23.3‡ CW 5-1-5 D-1-D V. D. 0-240 224 53.8 CW 1-4 1-D Single 240 50/60 5021-8P M5021-8P 0-280 224 62.7 CW 1-2 1-D Phase 22 642 663 5021E-8P M5021E-8P 224*-96 Parallel 120 50/60 0-280 26.9‡ CW 1-5 1-D V. D. Single 0-480 112 53.8 CW 4-4 D-D 480 50/60 5021-8PS M5021-8PS Phase 0-560 112 62.7 CW 2-2 D-D 22 & 4 640 742 5021E-8PS M5021E-8PS Series 112*-48 240 50/60 0-560 26.9‡ CW 5-5 D-D Parallel V. D. Single 5011-9P M5011-9P Phase 120 50/60 0-140 450 63.0 CW 1-2 1-D 22 721 742 5011E-9P M5011E-9P Parallel Three 5011-9Y M5011-9Y Phase 240 60 0-280 150 72.5 CW 2-2-2 D-D-D 22 & 6 717 738 5011E-9Y M5011E-9Y Wye 0-240 252 60.5 CW 1-4 1-D Single 240 50/60 5021-9P M5021-9P 0-280 252 70.6 CW 1-2 1-D Phase 22 721 742 5021E-9P M5021E-9P 252*-108 Parallel 120 50/60 0-280 30.2‡ CW 1-5 1-D V. D. 50/60 0-480 84 69.8 CW 4-4-4 D-D-D Three 480 5021-9Y M5021-9Y 60 0-560 84 81.5 CW 2-2-2 D-D-D Phase 22 & 6 717 738 5021E-9Y M5021E-9Y 84*-36 Wye 240 60 0-560 35.0‡ CW 5-5-5 D-D-D V. D. Three M5011-10D — Phase 120 50/60 0-140 250 60.6 CW 2-1-2 D-1-D 22 & 5 812 M5011E-10D Open Delta Single M5011-10PS Phase — 240 50/60 0-280 250 70.0 CW 2-2 D-D 22 & 4 812 M5011E-10PS Series Parallel 0-240 140 58.2 CW 4-1-4 D-1-D Three 240 50/60 M5021-10D 0-280 140 67.9 CW 2-1-2 D-1-D Phase 22 & 5 812 — M5021E-10D 140*-60 Open Delta 120 50/60 0-280 29.1‡ CW 5-1-5 D-1-D V. D. 5000 Series PART NUMBER INPUT OUTPUT SHAFT TERMINAL CONNECTIONS NET WEIGHT ROTATION For Increasing Voltage IN LBS. WIRING FOR As Viewed from Rotor End SCHE- (MAX) MANUALLY MOTOR VOLTS HERTZ VOLTS MAX MAX VOLTAGE MATIC MAN- MOTOR OPERATED DRIVEN AMPS KVA INCREASE INPUT OUTPUT (Pg 8 & 9) UAL DRIVEN Single 0-480 140 67.2 CW 4-4 D-D 480 50/60 M5021-10PS Phase 0-560 140 78.4 CW 2-2 D-D — 22 & 4 — 812 M5021E-10PS Series 140*-60 240 50/60 0-560 33.6‡ CW 5-5 D-D Parallel V. D. Three M5011-12D — Phase 120 50/60 0-140 300 72.7 CW 2-1-2 D-1-D 22 & 5 — 940 M5011E-12D Open Delta Single M5011-12PS Phase — 240 50/60 0-280 300 84.0 CW 2-2 D-D 22 & 4 — 940 M5011E-12PS Series Parallel 0-240 168 69.8 CW 4-1-4 D-1-D Three 240 50/60 M5021-12D 0-280 168 81.5 CW 2-1-2 D-1-D — Phase 22 & 5 — 940 M5021E-12D 168*-72 Open Delta 120 50/60 0-280 34.9‡ CW 5-1-5 D-1-D V. D. Single 0-480 168 80.6 CW 4-4 D-D 480 50/60 M5021-12PS Phase 0-560 168 94.1 CW 2-2 D-D — 22 & 4 — 940 M5021E-12PS Series 168*-72 240 50/60 0-560 40.3‡ CW 5-5 D-D Parallel V. D. Three M5011-14D — Phase 120 50/60 0-140 350 84.9 CW 2-1-2 D-1-D 22 & 5 — 1097 M5011E-14D Open Delta Single M5011-14PS Phase — 240 50/60 0-280 350 98.0 CW 2-2 D-D 22 & 4 — 1097 M5011E-14PS Series Parallel 0-240 196 81.5 CW 4-1-4 D-1-D Three 240 50/60 M5021-14D 0-280 196 95.1 CW 2-1-2 D-1-D — Phase 22 & 5 — 1097 M5021E-14D 196*-84 Open Delta 120 50/60 0-280 40.8‡ CW 5-1-5 D-1-D V. D. Single 0-480 196 94.1 CW 4-4 D-D 480 50/60 M5021-14PS Phase 0-560 196 109.8 CW 2-2 D-D — 22 & 4 — 1097 M5021E-14PS Series 196*-84 240 50/60 0-560 47.1‡ CW 5-5 D-D Parallel V. D. Three M5011-16D — Phase 120 50/60 0-140 400 96.7 CW 2-1-2 D-1-D 22 & 5 — 1254 M5011E-16D Open Delta Single M5011-16PS Phase — 240 50/60 0-280 400 112.0 CW 2-2 D-D 22 & 4 — 1254 M5011E-16PS Series Parallel Three 0-240 224 93.1 CW 4-1-4 D-1-D 240 50/60 M5021-16D Phase 0-280 224 108.6 CW 2-1-2 D-1-D — 22 & 5 — 1254 M5021E-16D Open Delta 224*-96 120 50/60 0-280 46.6‡ CW 5-1-5 D-1-D V. D. Single 0-480 224 107.5 CW 4-4 D-D 480 50/60 M5021-16PS Phase 0-560 224 125.5 CW 2-2 D-D — 22 & 4 — 1254 M5021E-16PS Series 224*-96 53.8‡ 240 50/60 0-560 CW 5-5 D-D Parallel V. D. Three M5011-18D — Phase 120 50/60 0-140 450 109.0 CW 2-1-2 D-1-D 22 & 5 — 1417 M5011E-18D Open Delta Single M5011-18PS Phase — 240 50/60 0-280 450 126.0 CW 2-2 D-D 22 & 4 — 1417 M5011E-18PS Series Parallel 0-240 252 104.5 CW 4-1-4 D-1-D Three 240 50/60 M5021-18D 0-280 252 122.2 CW 2-1-2 D-1-D — Phase 22 & 5 — 1417 M5021E-18D 252*-108 Open Delta 120 50/60 0-280 52.5‡ CW 5-1-5 D-1-D V. D. Single 0-480 252 121.0 CW 4-4 D-D 480 50/60 M5021-18PS Phase 0-560 252 141.0 CW 2-2 D-D — 22 & 4 — 1417 M5021E-18PS Series 252*-108 240 50/60 0-560 60.5‡ CW 5-5 D-D Parallel V. D. Three M5011-12Y — Phase 240 60 0-280 200 96.7 CW 2-2-2 D-D-D 22 & 6 — 942 M5011E-12Y Wye 50/60 0-480 112 93.1 CW 4-4-4 D-D-D Three 480 M5021-12Y 60 0-560 112 108.6 CW 2-2-2 D-D-D — Phase 22 & 6 — 942 M5021E-12Y 112*-48 Wye 240 60 0-560 46.6‡ CW 5-5-5 D-D-D V. D. 5000 Series PART NUMBER INPUT OUTPUT SHAFT TERMINAL CONNECTIONS NET WEIGHT ROTATION For Increasing Voltage IN LBS. WIRING FOR As Viewed from Rotor End SCHE- (MAX) MANUALLY MOTOR VOLTS HERTZ VOLTS MAX MAX VOLTAGE MATIC MAN- MOTOR OPERATED DRIVEN AMPS KVA INCREASE INPUT OUTPUT (Pg 8 & 9) UAL DRIVEN Three M5011-15Y — Phase 240 60 0-280 250 121.0 CW 2-2-2 D-D-D 22 & 6 — 1179 M5011E-15Y Wye 50/60 0-480 140 116.5 CW 4-4-4 D-D-D Three 480 M5021-15Y 60 0-560 140 136.0 CW 2-2-2 D-D-D — Phase 22 & 6 — 1179 M5021E-15Y 140*-60 Wye 240 60 0-560 58.2‡ CW 5-5-5 D-D-D V. D. Three M5011-18Y — Phase 240 60 0-280 300 145.5 CW 2-2-2 D-D-D 22 & 6 — 1415 M5011E-18Y Wye 50/60 0-480 168 139.5 CW 4-4-4 D-D-D Three 480 M5021-18Y 60 0-560 168 163.3 CW 2-2-2 D-D-D — Phase 22 & 6 — 1415 M5021E-18Y 168*-72 Wye 240 60 0-560 70.0‡ CW 5-5-5 D-D-D V. D. Three M5011-21Y — Phase 240 60 0-280 350 169.5 CW 2-2-2 D-D-D 22 & 6 — 1654 M5011E-21Y Wye 50/60 0-480 196 163.0 CW 4-4-4 D-D-D Three 480 M5021-21Y 60 0-560 196 189.5 CW 2-2-2 D-D-D — Phase 22 & 6 — 1654 M5021E-21Y 196*-84 Wye 240 60 0-560 82.0‡ CW 5-5-5 D-D-D V. D. Three M5011-24Y — Phase 240 60 0-280 400 193.7 CW 2-2-2 D-D-D 22 & 5 — 1892 M5011E-24Y Wye 50/60 0-480 224 186.5 CW 4-4-4 D-D-D Three 480 M5021-24Y 60 0-560 224 217.8 CW 2-2-2 D-D-D — Phase 22 & 6 — 1892 M5021E-24Y 224*-96 Wye 240 60 0-560 93.0‡ CW 5-5-5 D-D-D V. D. Three M5011-27Y — Phase 240 60 0-280 450 218.4 CW 2-2-2 D-D-D 22 & 6 — 2131 M5011E-27Y Wye 50/60 0-480 252 209.5 CW 4-4-4 D-D-D Three 480 M5021-27Y 60 0-560 252 244.0 CW 2-2-2 D-D-D — Phase 22 & 6 — 2131 M5021E-27Y 252*-108 Wye 240 60 0-560 105.0‡ CW 5-5-5 D-D-D V. D. * Maximum output current in output voltage range from 0 to 25 percent above line voltage. At higher output voltages, output current must be reduced according to rating curve, Figure B, page 6. ‡ Maximum KVA at maximum output and corresponding de-rated current. Maximum KVA at lower output voltages may be calculated from derating curve. Figure B, page 6. V. D. Voltage Doubler 5000/6000 Series 30M5011-3Y 30M6020-9Y Enclosed Unit 5000/6000 Series Manual Single, Uncased Two Ganged Three Ganged A 17.06” [433.3] 23.12” [587.4] B 13.56” [344.4] 19.62” [498.3] C 15.12” [384.2] 21.19” [538.2] Manual Two and Three-Ganged, Uncased Manual Single, Cased Manual Two-Ganged, Cased Single Unit Two Ganged A 12.94” [328.6] 19.18” [487.3] B 15.50” [393.7] 21.56” [547.6] Motor Driven, Single and Two-Ganged, Cased Single Unit Two Ganged Three Ganged A 13.25” [336.6] 19.32” [490.7] 25.38” [644.5] B 9.75” [247.7] 15.82” [401.8] 21.88” [555.7] C (5 sec.) 13.53” [343.7] 19.62” [498.5] 25.75” [654.0] C (15, 30 & 60 sec.) 15.12” [384.2] 21.19” [538.2] 27.25” [692.0] Motor Driven, Single,Two and Three-Ganged, Uncased 5000/6000 Series 3 Ganged 4, 5, 6 Ganged 7, 8, 9 Ganged A 35.8” [909.32] 54.8” [1391.9] 72.8” [1849.1] Manual Three to Nine-Ganged, Cased AB 4 Ganged 30.38” [771.5] 27.38” [695.3] 5 Ganged 36.44” [925.5] 33.44” [849.3] 6 Ganged 42.50” [1079.5] 39.50” [1003.3] 7 Ganged 48.56” [1233.5] 45.56” [1157.3] 8 Ganged 54.62” [1387.5] 51.62” [1311.3] 9 Ganged 60.69” [1541.5] 57.69” [1465.3] Manual Four to Nine-Ganged, Uncased 3 Ganged 4, 5, 6 Ganged 7, 8, 9 Ganged A 33.5” [850.9] 52.5” [1333.5] 70.5” [1061.9] Motor-Driven Three to Nine-Ganged, Cased 5021-3Y 10 & 12 Ganged 14, 16 & 18 Ganged A 52.5” [1333.5] 70.5” [1790.7] Motor-Driven 10, 12, 14, 16 & 18-Ganged Open Delta and Parallel, Cased 5000/6000 Series 12 Ganged 15 Ganged 18 Ganged 21 Ganged 24 Ganged 27 Ganged A 36.31” [922.3] 42.38” [1076.4] 48.44” [1230.3] 54.50” [1384.3] 60.56” [1538.3] 66.62” [1692.3] B 30.94” [786.8] 37.00” [939.8] 43.06” [1093.8] 49.12” [1247.8] 55.19” [1401.8] 61.25” [1555.8] Motor-Driven 12, 15, 18, 21, 24 & 27-Ganged, Uncased 12, 15, 18 Ganged 21, 24, 27 Ganged A 52.5” [1333.5] 70.5” [1790.7] Motor-Driven 12, 15, 18, 21, 24 & 27-Ganged, Cased 10 Ganged 12 Ganged 14 Ganged 16 Ganged 18 Ganged 60M5021-27Y A 42.38” [1076.3] 48.44” [1230.3] 54.50” [1384.3] 60.56” [1538.3] 66.62” [1692.3] B 37.00” [939.8] 43.06” [1093.8] 49.12” [1247.8] 55.19” [1401.8] 61.25” [1555.8] Motor-Driven 10, 12, 14, 16 & 18-Ganged Open Delta & Parallel, Uncased

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 5021E-4P have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Staco Energy Products 5011 Manually Operated Variable Transformer, single phase wiring, input 120 vo...

Staco Energy Products 5011-2D Manually Operated Variable Transformer, three phase open delta wiring,...

Staco Energy Products 5011-2P Manually Operated Variable Transformer, single phase wiring, input 120...

Staco Energy Products 5011-2S Manually Operated Variable Transformer, single phase wiring, input 240...

Staco Energy Products 5011-3P Manually Operated Variable Transformer, single phase wiring, input 120...

Staco Energy Products 5011-3Y Manually Operated Variable Transformer, three phase open delta wiring,...