SST 5136-CN-ISA
Specifications
16-bit ISA memory
ISA I/O Region
Bus Interface
16 bit, half-length ISA
Diagnostics
three LEDs; two for network status and one for system status
Dimensions
6.225 in x 4.2 in
I/O memory
One ISA interrupt
ISA Memory Region
512K of
Memory
Min. 8K Window in host memory map
Processor
Intel i960 32-bit RISC 33 Mhz
Typical Current Draw
650 mA @ 5V
Voltage Requirements
5V
Features
- 1 Mbyte local 32-bit RAM
- 16-bit, half-length ISA interface card
- 2 BNC connectors
- 512 Kbytes of 16-bit Flash memory
- 512 Kbytes of shared 16-bit RAM
- 5136-SD DH+ Emulation
- Applications using interrupts may require minor changes
- ControlNet Conformance Tested
- ControlNet redundancy implemented in hardware on interface card
- FPGA executes all protocol activity, including scanning I/O, without intervention from i960 processor
- FPGA is software field upgradeable
- Intel i960 32-bit RISC 30 Mhz processor
- Isolated Network Access Port (NAP)
- LAN Controller (no ControlNet ASICs used) is implemented in a field programmable gate array (FPGA)
- Network Interface
- Operational temperature: 0 to 50C (32 to 122o F)
- Power requirements: 650 mA @ 5 V
- Standard ControlNet LEDs for each channel
- Storage temperature: -25 to 70C (-13 to 158o F)
- Supports standard PCCC messaging
Datasheet
5136-CN-ISA_d-1983818132s.pdf
227 KiB
Extracted Text
™ ™ ™ The BradCommunications SST ControlNet Interfaces provide high-performance control and the support required for your ControlNet applications. ™ ControlNet PC Interfaces For Controlling and Monitoring ControlNet Applications Features • High performance • 32-bit i960 RISC CPU • Simultaneous operation of 128 scheduled and 128 unscheduled message screeners • Simultaneous functionality of ControlNet messaging, scanner and adapter PCI Format • Ease of Use • Designed to work with any existing SST 5136-SD DH+ software driver for Operator Interface and HMI applications • Works with Rockwell Software’s RSLinx allowing compatibility with Rockwell’s “RS” family of products • Integrated configuration tool included for ControlNet scanner applications PC/104 Format • Diagnostic LEDs • Network redundancy supported ISA Format • Support for various bus formats • ControlNet conformance tested Software Tools Included • Network capture tool • Network analyzer ™ ™ The BradCommunications SST network interface cards are ideal for • OPC server applications where high-performance control and reliability are required. Backed by superior support and service, Woodhead network interfaces support OS and Drivers Supported a wide range of network protocols and bus formats. • Microsoft Windows NT drivers/DLLs Overview • Open, documented memory map interface with example C source ™ code and Windows 32-bit DLLs for The BradCommunications SST Network Interface Cards for ControlNet custom driver development connect your computer to ControlNet. Applications where it can be found include: • Rockwell Software RSLinx support • Operator Interface • Human-Machine Interface • SCADA • PC Control • PLC programming • Network configuration • Network troubleshooting and diagnostics ™ ™ SST ControlNet Interfaces Network Specifications ™ Protocol • ControlNet Data Rate • All ControlNet data rates • RG6 Cable • Drop cable to tap should be 1 meter long • 2 BNC connectors for redundant connections Connector • Standard ControlNet NAP port Hardware Specifications PCI ISA PC/104 Bus Interface Compliant with PCI 2.1 16 bit, half-length ISA Compliant with PC/104 Processor Intel i960 32-bit RISC 33 Mhz Min. 8K Window Min. 8K Window in Memory 1 MB in host memory map host memory map (max. 512K and default 16K) (max. 512K and default 16K) Diagnostics three LEDs; two for network status and one for system status Interrupts optional Software selectable level IRQ 0 through 7 Dimensions 6.875 in x 4.2 in 6.225 in x 4.2 in 9.588 cm x 9.017 cm (Length x Width) (17.463 cm x 10.668 cm) (15.812 cm x 10.668 cm) (3.775 in x 3.550 in) Typical Current Draw 650 mA @ 5V Voltage Requirements 5V PCI Region 0 = 128 bytes PCI memory ISA Memory Region = 512K of PC/104 Memory Region = 512K PCI Region 2 = 1MB of 32-bit 16-bit ISA memory of 16-bit PC/104 memory Resources PCI memory ISA I/O Region = 8 bytes of ISA PC/104 I/O Region = 8 bytes of PCI Region 3 = 32 bytes of I/O memory PC/104 I/O memory 32-bit PCI memory One ISA interrupt One PC/104 interrupt One PCI interrupt Certifications ControlNet conformance tested Operating Temperature 0ºC (32ºF) up to +50ºC (122ºF) Storage Temperature -25ºC (-13°F) up to +70ºC (158°F) Humidity 5% to 95% non-condensing Ordering Information Part Number Product Description 5136-CN-PCI ControlNet card, PCI 5136-CN-ISA ControlNet card, ISA 5136-CN-104 ControlNet card, PC/104 Other ControlNet Part Numbers: 5136-CN-VME ControlNet card, VME To contact us: www.woodhead.com Reference Number: DW2006122 Date Published: January 2006 North America: US + 1 800 225 7724 -Canada, +1 519 725 5136 Europe: France, +33 2 32 96 04 20 – Germany, +49 711 782 3740 – Italy, +39 010 59 30 77 – United Kingdom, +44 1495 356300 Asia: China, +86 21-5835-9885 – Singapore, +65-6261-6533 – Japan, +81-3-5791-4621 BradCommunications and SST are trademarks of Woodhead Industries, Inc. © 2005 Woodhead Industries, Inc.
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the 5136-CN-ISA have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
SST 5136-DNP-104 is a PC/104 interface card for communication with DeviceNet and other CAN-based net...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods