SSAC ARP43S

Image of SSAC ARP43S

Description

Alternating Relay, Contact Form DPDT, Input Line Voltage 120 VAC, Maximum Output Current @ 240 VAC 10 Amps, Maximum Line Voltage 250 VAC

Part Number

ARP43S

Price

Request Quote

Manufacturer

SSAC

Lead Time

Request Quote

Category

PRODUCTS - A

Specifications

AC Line Frequency

50/60Hz

Type

Electro-mechanical relay

Voltage

24,120 or 230VAC

Features

Datasheet

pdf file

SSAC-ARP43S- Alternating Relay-datasheet1-587371155.pdf

746 KiB

Extracted Text

Alternating Relay ARP Series The ARP Series is used in systems where equal Features: run time for two motors is desirable. The selector switch allows selection of alternation of either load • Provides equal run time for two motors for continuous operation. LED’s indicate the status • Alternating or electrically locked operation of the output relay. This versatile series may be • Low profile selection switch front panel mounted (BZ1 accessory required) or • 10A output contacts 35 mm DIN rail mounted with an accessory socket. • LED status indication • Industry standard base connection For more information see: Approvals: Appendix B, page 167, Figure 31 for dimensional drawing. Appendix C, 170, Figure 29 for connection diagram. Auxiliary Products: • Hold-down clips (sold in pairs): P/N: PSC8 (NDS-8) P/N: PSC11 (NDS-11) • Panel mount kit: P/N: BZ1 Operation • 11-pin socket: P/N: NDS-11 Alternating: When the rotary switch is in the “alternate” position, alternating operation of Load A and Load B • 8-pin socket: P/N: NDS-8 occurs upon the opening of the control switch S1. To terminate alternating operation and cause only the selected • DIN rail: P/N: C103PM load to operate, rotate the switch to position “A” to lock Load A or position “B” to lock Load B. The LEDs indicate the status of the internal relay and which load is selected to operate. Note: Input voltage must be applied at all times for proper alternation. The use of a solid-state control switch Available Models: for S1 may not initiate alternation correctly. S1 voltage must be from the same supply as the unit’s input ARP23S ARP43S voltage (see connection diagrams). Loss of input voltage resets the unit; Load A becomes the lead load for ARP41 ARP61S the next operation. ARP41S ARP63 Duplexing (Cross Wired): Duplexing models operate the same as alternating relays and when both the Control ARP42S ARP63S (S1) and Lag Load (S2) Switches are closed, Load A and Load B energize simultaneously. ARP43 The DPDT 8-pin, cross-wired option, allows extra system load capacity through simultaneous operation of both motors when needed. Relay contacts are not isolated. If desired part number is not listed, please call us to see if it is technically possible to build . Order Table: ARP X X X Input Output Form Switch Operation ─2 - 24VAC ─1 - SPDT, 8-pin ─Blank - No Switch ─4 - 120VAC ─2 - DPDT, 11-pin ─S - Rotary Switch ─6 - 230VAC ─3 - DPDT, 8-pin cross wired Specifications Input Protection Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24, 120, or 230VAC Isolation Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≥ 1500V RMS input to output Tolerance 24VAC . . . . . . . . . . . .-15% - 20% Mechanical 120 & 230VAC . . . . . . . . . . . .-20% - 10% Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Plug-in socket AC Line Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . .50/60Hz Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.2 x 2.39 x 1.78 in. (81.3 x 60.7 x 45.2 mm) Output Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Octal 8-pin or magnal 11-pin Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Electromechanical relay Environmental Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SPDT, DPDT, or cross wired DPDT Operating / Storage Temperature . . . . . . . . . . . . . . .-20° to 60°C / -30° to 85°C Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10A resistive @ 120/240VAC & 28 VDC; Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .≅ 5.6 oz (159 g) 1/3 hp @ 120/240VAC Maximum Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250VAC NOTE: Unit does not have debounce time delay. 7 6 Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mechanical - 1 x 10 ; Electrical - 1 x 10 www.ssac.com • 800-843-8848 • fax: 605-348-5685 135 Appendix B - Dimensional Drawings FIGURE 25 FIGURE 24 FIGURE 26 CURRENT LIMITING RESISTOR 0.28 (7.11) 2 24 AWG (0.25 mm ) < _ 0.22 UL1007 (5.59) STRIPPED 0.25 (6.35) 0.53 12 ± 1 (13.46) (304.8 ± 25.4) LPM FIGURE 27 MSM = Nylon Standoffs LLC1 FIGURE 28 FIGURE 29 [ ] [ ] [ ] [ ] LLC5 LLC2 LLC8 FIGURE 30 FIGURE 33 FIGURE 32 TVM; TVW FIGURE 31 FB; SCR PCR ARP inches (millimeters) www.ssac.com • 800-843-8848 • fax: 605-348-5685 167 Appendix C - Connection Diagrams FIGURE 23 - LLC1 Series FIGURE 22 - LCS10T12 FIGURE 24 - LLC4 Series C Metal Tank or use additional Probe Metal Tank or use additional Probe P = Probe L1 N/L2 Wire Length: 500 ft. (152.4m) max. (Customer L = Load P = Probe Supplied) L1 N/L2 V = Voltage C = Probe Common CAUTION: The LCS10T12 must be connected to ∆S = Sensitivity Adjustment V = Voltage the LPM12 or LPMG12 before current flows to Connect common to conductive tank Relay contacts are isolated . prevent damage or shock hazard. Monitored wires or an additional probe as required . Connect common to conductive tank. Additional probe must be properly insulated . Contacts A, B & C are isolated. is necessary for non-conductive or insulated tanks. FIGURE 25 - LLC8 Series FIGURE 26 - LLC6 Series FIGURE 27 - LLC2 Series N/L2 L1 Metal Tank or use Metal Tank or use additional Probe additional Probe PC = Probe Common P = Probe V = Voltage Metal Tank or use V = Voltage L1 N/L2 L = Low Probe additional Probe R = Optional NC Reset Switch H = High Probe V = Voltage Connect common to conductive tank. Additional probe C = Probe Common LLCO = Low Level Probe is necessary for non-conductive or insulated tanks. ∆S = Sensitivity Adjustment G or CP = Ground or Common (Reference) Probe NC = Normally Closed R = Optional NC Reset Switch (not included) NO = Normally Open NO = Normally Open Connect common to conductive tank. NC = Normally Closed Additional probe is necessary for non- C = Common or Transfer Contact conductive or insulated tanks. Relay contacts are isolated . FIGURE 29 - ARP Series Connect common to conductive tank. Additional L1 N/L2 probe is necessary for non-conductive or insulated tanks. SPDT 8-pin FIGURE 28 - LLC5 Series L1 N/L2 DPDT 11-pin Metal Tank or use additional Probe L1 N/L2 HP = High Level Probe LP = Low Level Probe C = Probe Common V = Voltage Relay contacts are isolated . Relay contacts in above are isolated. Connect common to conductive tank. Additional probe is necessary for non-conductive or insulated tanks. L1 N/L2 DPDT 8-pin cross wired Duplexing (Cross Wired): Duplexing models operate the same as alternating relays and when both the Control (S1) and Lag Load (S2) Switches are closed, Load A and Load B energize simultaneously. The DPDT 8-pin, cross wired option, allows extra system load V = Voltage capacity through simultaneous operation of both motors when LA = Load A needed . Relay contacts are not isolated . LB = Load B S1 = Primary Control Switch S2 = Lag Load Switch 170 www.ssac.com • 800-843-8848 • fax: 605-348-5685

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the ARP43S have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

FLASHER

FLASHER

Alternating Relay, Contact Form DPDT, Input Line Voltage 24 VAC, Maximum Output Current @ 240 VAC 10...

TIMER/RELAY ALTERNATING/DUPLEXOR SPDT 10AMP 120VAC

RELAY