SQUARE D HCP18686M

Description
Square D's HCP18686M PNLBD INT I-LINE Model, main amperes rating: 600A, main type: circuit breaker, maximum voltage rating: 600VAC to 250VDC, approval: UL Listed, catalog reference number: 2110CT9701, bus-bar material: aluminum, marketing trade name: I-Line, the circuit breaker mounting space: 36 inches, and it is extremely useful.
Part Number
HCP18686M
Price
Request Quote
Manufacturer
SQUARE D
Lead Time
Request Quote
Category
PRODUCTS - H
Datasheet
Extracted Text
Product Data Sheet HCP18686M Panelboard Interior, Main Type: Circuit Breaker, Bus Ampere Rating: 600A List Price $7,393.00 USD Availability Non-Stock Item: This item is not normally stocked in our distribution facility. Technical Characteristics Main Amperes Rating 600A Main Type Circuit Breaker Maximum Voltage Rating 600VAC - 250VDC Approvals UL Listed Catalog Reference Number 2110CT9701 Busbar Material Aluminum Marketing Trade Name I-Line Circuit Breaker Mounting Space 36 Inches Bus Ampere Rating 600A Type HCP Mounting Type Panel Service Feed Location Bottom Wiring Configuration 3-Wire Depth 9.50 Inches Number of Poles 3-Pole Space Required 3 Phase 3-Phase Height 68 Inches Width 42 Inches Shipping and Ordering Category 00016 - Panelboards,Ready to Install, Type I-Line Discount Schedule PE1A Article Number 785901508236 Package Quantity 1 Weight 130 lbs. Availability Code Non-Stock Item: This item is not normally stocked in our distribution facility. Returnability Y As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. Generated: 06/18/2009 04:12:15 © 2009 Schneider Electric. All rights reserved. 1 Table of Contents Section 9 Panelboards Series Rated / Fully Rated Tables NQ 9-2 NF 9-3 ® I-Line 9-3 Lighting and Appliance Panelboards NF/NQ Pricing Procedures 9-5 NQ Merchandised Main Lug Panelboards 9-6 New! Merchandised Main Circuit Breaker Panelboards 9-7 NQ Panelboards Merchandised Main Lug & Main Circuit Breaker 9-8 Page 9-5 Merchandised Accessories 9-9 QOB Branch Circuit Breakers 9-10 Factory Assembled Panelboards and Circuit Breakers 9-11 Factory Assembled Common Features 9-12 NF Merchandised Main Lugs Panelboards 9-13 Merchandised Main Circuit Breaker Panelboards 9-13 Merchandised Main Lug & Main Circuit Breaker Panelboards with TVSS 9-13 Merchandised Accessories 9-14 EDB, EGB, EJB Branch Circuit Breakers 9-15 Factory Assembled Panelboards 9-18 Factory Assembled Common Features 9-19 NF/NQ Merchandised Single Row (Column Width) Panelboards 9-16 Column Width M NQ 14 inch Wide Panelboards 9-41 New! NF Panelboards Page 9-13 Power Distribution Panelboards—Circuit Breaker Type ® I-Line Pricing Procedure 9-20 Merchandised Panelboards (HCN, HCM, HCP-SU) 9-21 Merchandised Panelboards (HCP, HCR-U) 9-22 Merchandised Accessories 9-23 Circuit Breakers 9-24 H-frame and J-frame Circuit Breakers 9-26 K-frame and R-frame Circuit Breakers 9-27 L-frame Circuit Breakers 9-28 M-frame Circuit Breakers 9-29 ® I-Line Panelboards P-frame Circuit Breakers 9-30 Page 9-20 Factory Assembled Pricing 9-31 Factory Assembled Branch Circuit Breakers 9-32 Factory Assembled Common Features 9-33 Power Distribution Panelboards—Fusible Type QMB Replacement Switches 9-34 Factory Assembled Pricing 9-35 Factory Assembled TVSS Units 9-36 Panelboard Special Features Factory Assembled Modifications 9-37 Terminal Data 9-38 QMB Panelboards 9-40 Page 9-34 CTC Cabinets—Wall Mounted Metering Equipment © 2009 Schneider Electric 9-1 All Rights Reserved PANELBOARDS 9 PANELBOARDS 9 ® I-Line Merchandised 600 Vac, 250 Vdc Panelboards Class 2110 / Refer to Catalog 2110CT9701 www.schneider-electric.us Table 9.97: (1200 A Interiors Include solid neutral, all others without solid neutral. TYPE HCP Order solid neutral from 9-23.) 800 A max. branch circuit breaker Complete Fronta Surface FAa, FH, FI, FY, QB, QD, Total Max. $ Price Interior Assembly QG, QJ, HD, HG, HJ, HL, JD, Circuit No. of Box c Box (4 Piece Trim) (Less Branch Circuit Breakers) 4 Piece Trim Breaker LC, MJ, JG, JJ, JL, KI, Q4, LA, LH, Trim With Door Height (Less Branch Without Doorb Mtg. PL, RL LC, LI, LX, LXI, LE, MG, MJ, (In.) Breakers) Space Circuit PG, PJ, PL, PGC, PJC, (Inches) Breakers Catalog Catalog Catalog Catalog PLCb Type 1 $ Price $ Price $ Price $ Price Number Number Number Number HCP Main Lugs Only—3-pole QB, QD FA, FH, FY HD, HG QG, QJ Suitable for use as service equipment when provided with a main circuit breaker. d 1 HJ, HL ⁄2 Total FA, FH, FY Breaker QB, QD HD, HG 400 2751. HCP14504 1902. Mounting QG, QJ HJ, HL Space FI, KI, JD FI, KI, JD 600 3513. HCP14506 2664. Each JG, JJ, JL JG, JJ, JL 27 1PL HCW50T( ) 606. HCW50T( )D 743. HC4250DB 243. 50 Side 800 4521. HCP14508 3672. Q4, LA, LH LC, LI, LX 1200 6365. HCP145012N 5516. LXI, LE MG, MJ 400 3212. HCP23594 2298. PG, PJ, PL PGC, PJC, PLC 600 3860. HCP23596 2946. 45 2PL HCW59T( ) 671. HCW59T( )D 827. HC4259DB 243. 59 800 4874. HCP23598 3960. 1200 A Max. Main Lugs S or N 1200 7133. HCP235912N 6219. 800 A Max. Main Breaker 400 3795. HCP32684 2706. 600 4476. HCP32686 3387. Box Size: 63 3PL HCW68T( ) 846. HCW68T( )D 1052. HC4268DB 243. 68 800 5309. HCP32688 4220. 42 in. Wide, 9.5 in. Deep 1200 7763. HCP326812N 6674. a FA and KA circuit 400 4716. HCP50864 3372. breakers with field installable ground fault 600 5208. HCP50866 3864. 99 5PL HCW86T( ) 1101. HCW86T( )D 1344. HC4286DB 243. 86 kits may be mounted in 800 6194. HCP50868 4850. type HCP, HCP-SU and 1200 8529. HCP508612N 7185. HCR-U panelboards as shown, and require L HCP Main Circuit Breakere—Includes 3-pole frame mounting space. Vertically mounted main circuit breaker—Suitable for use as service equipment. b PG, PJ, PL circuit 600 12179. HCP18686M 11090. breakers are available 36 2LC HCW68T( ) 846. HCW68T( )D 1052. HC4268DB 243. 68 with both thermal- 800 15399. HCP18688M 14310. magnetic equivalent 600 12987. HCP36866M 11643. and Micrologic trip. The 72 4LC HCW86T( ) 1101. HCW86T( )D 1344. HC4286DB 243. 86 800 16296. HCP36868M 14952. Micrologic circuit breakers are available HCR-U Universal Main Lugs or Main Circuit Breakere—3-pole 80% and 100% rated. Suitable for use as service equipment when provided with a main circuit breaker. “C” suffix denotes a For MAIN LUGS panel, order sub-feed lug kit catalog number S33930 and back feed as main lugs. 100% rating. For MAIN CIRCUIT BREAKER panel, order plug-on I-LINE type PG, PJ, PL, RGC, RJC or RLCf circuit breakers from pages 9-27 through 9-29, TYPE HCR-U and back feed as the main circuit breaker. (Order solid neutral separately) Universal Mains 108g 1200 6PL or 3RLC 12557. HCR548612U 11213. HCR86T( )h 1101. HCR86T( )D 1344. HC4486DB 243. 86 1200 A max. branch circuit breaker a Add “F’’ for Flush or “S’’ for Surface. FAa, FH, FI, FY, QB, QD, b Add-on door kit available. Example: For HCW50TS trim kit, order HCW50D door kit. QG, QJ, HD, HG, HJ, HL, JD, c See 9-23 for 42 in. wide weatherproof enclosures. JG, JJ, JL, KI, Q4, LA, LH, d Suitable for use as service equipment if equipped with an integral main circuit breaker or when not more than six main disconnecting means are provided LC, LI, LX, LXI, LE, MG, MJ, and the panelboard is not used as a lighting and appliance branch circuit panelboard. PG, PJ, PL, PGC, PJC, PCL, e Circuit breaker interrupt ratings, starting on page 7-2. RGC, RJC, RLCbc f When RL main circuit breakers with equipment ground fault are applied on a 3Ø4W system, order solid neutral catalog number HCR12SNCT. The HCR12SNCT includes a neutral current transformer. g 15 in. of mounting space is taken up by the back fed main lug kit or RG, RJ, RL main circuit breaker, leaving 93 in. of branch circuit breaker mounting space. FA, FH, FY QB, QD h Add-on door kit available. Example: For HCR86TS trim kit, order HCW86D door kit. QG, QJ HD, HG HJ, HL 1 ⁄2 Total FA, FH, FY Breaker QB, QD HD, HG Mounting HJ, HL QG, QJ Space Each FI, KI, JD FI, KI, JD Table 9.98: Circuit Breaker / Sub-feed Lug Kit Mounting Inch Requirement Side JG, JJ, JL JG, JJ, JL Q4, LA, LH Maximum No. of Mounting Maximum No. of Mounting Type of Circuit Breaker Type of Circuit Breaker LC, LI, LX Ampacity Poles Requirement Ampacity Poles Requirement LXI, LE FY 30 A 1 1.5 in. QB, QD, QG, QJ 225 A 3 4.5 in. MG, MJ FA, FH 1 1.5 in. JD, JG, JJ, JL, KI, SL250 250 A 4.5 in. PG, PJ, PL PGC, PJC, PLC FA, FH 100 A 2 3 in. LA, LH, Q4, SL400 400 A 2, 3 6 in. RGC, RJC, RLC FA, FH, FI, SL-100 2, 3 4.5 in. LC, LI, LX, LXI, LE 600 A 7.5 in. HD, HG 2 3 in. MG, MJ, MA, MH, SL800 800 A 1200 A Max. Main Lugs or S/N 150 A 9in. 1200 A Max. Main Breaker HD, HG, HJ, HL 2, 3 4.5 in. PG, PJ, PL, PGC, PJC, PLC, S33931 1200 A 2, 3 QB, QD, QG, QJ 225 A 2 3 in. RGC, RJC, RLC, S33930 1200 A 15 in. Box Size: 44 in. Wide, 9.5 in. Deep a FA and KA circuit breakers with field installable ground fault Table 9.99: Main Circuit Breaker Interiors — Table 9.100: Standard Copper Bus Interiors a kits may be mounted in type HCP, HCP-SU and Standard Frame Types a Type Main Ampacity HCR-U panelboards as HCN 600 shown, and require L Main Circuit Panelboard Factory Supplied frame mounting space. Breaker Ampacity Type Main Circuit Breaker HCM, HCP-SU 800 b When RL main circuit 100 HCN FA36100 HCP, HCR-U 800 & Above breakers with 225 HCN, HCM KA36225 equipment ground fault a Merchandised copper interiors are not available in all ampacities. are applied on a 3Ø4W HCN LAP36400MB Example: Application calls for a HCN 225A copper bus interior, order a 400 system, order solid HCM LAP36400MB HCN 600A interior See table 9.100 neutral catalog number 600 MGP36600 HCR12SNCT. The or HCM, HCP or HCR12SNCT includes 800 MGP36800 a neutral current transformer. a Circuit breaker interrupt ratings, starting on page 7-2. c PG, PJ, PL circuit breakers are available with both thermal- magnetic equivalent and Micrologic trip. The Micrologic circuit breakers are available 80% and 100% rated. “C” suffix denotes a 100% rating. Discount © 2009 Schneider Electric 9-22 PE1A Schedule All Rights Reserved Mains Amp. Rating
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the HCP18686M have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods