Elite.Parts chervon right Manufacturers chervon right S chervon right SPECTRONICS chervon right BLE-100S/MR
About product Datasheet FAQ

SPECTRONICS BLE-100S/MR

Description

Spectronics BLE-100S Spot Bulb - 100 Watt, Medium Base

Part Number

BLE-100S/MR

Price

Request Quote

Manufacturer

SPECTRONICS

Lead Time

Request Quote

Category

PRODUCTS - B

Datasheet

pdf file

Spectronics-BLE-100S-ds1-316175087.pdf

244 KiB

Extracted Text

SPECTRONICS CORPORATION BLE-100S/MR Bulb Effective: 1/25/07 PRODUCT SAFETY DATA SHEET Page 1 Supersedes: N/A BLE-100S/MR bulbs supplied by Spectronics Corporation are exempted from the requirements of the OSHA Hazard Communication Standard (29 CFR 1910.1200) because they are “articles.” We provide the following information as a courtesy to our customers. Section 1. Identification of the Product and Company PRODUCT NAME: BLE-100S/MR Section 6. Operating Lamps with Mercury Bulbs DESCRIPTION: Medium-Pressure, Mercury-Vapor Bulbs WARNING: EMERGENCY TELEPHONE #: 800-424-9300 (24 HOURS)  Mercury lamp arc-tubes operate at high pressure and high CHEMTREC; Call collect outside continental U.S.: 703-527-3887. temperature and may unexpectedly rupture. PRODUCT INFORMATION: Spectronics Corporation, 956 Brush  If the outer jacket is broken and the lamp continues to operate, Hollow Road, Westbury, NY 11590, 800-274-8888. ultraviolet radiation will be emitted. Prolonged exposure to UV For calls originating outside continental U.S.: 516-333-4840. may cause skin and eye irritation. Immediately shut power off and replace lamp.  Mercury bulbs must be operated only in suitably designed Section 2. Composition/Information on Ingredients fixtures. Exposure Limits in Air Chemical CAS (mg/cubic m) Name Number % by wt. ACGIH (TLV) OSHA (PEL) Section 7. Bulb Materials THERE ARE NO KNOWN HEALTH HAZARDS FROM Lead Solder EXPOSURE TO BULBS THAT ARE INTACT. No adverse effects (as PB) (1,2) 7439-92-1 0-<1.0 0.05 0.05 are expected from occasional exposure to broken bulbs. As a Mercury (1,2 7439-97-6 0.01-<0.1 0.025 0.1 Ceiling matter of good practice, avoid prolonged or frequent exposure to Quartz, fused 60676-86-0 5-15 0.1 Resp. Dust 0.1 broken bulbs unless there is adequate ventilation. The major Glass (Lead hazard from broken bulbs or lamps is the possibility of sustaining Borosilicate) (1,2) — 0-75 10 (3) 15 (3) (as Lead glass cuts. NIOSH/OSHA Occupational Health Guidelines for Chem- Oxide, 6%) (1,2) 1317-36-8 — 0.05 0.05 ical Hazards and/or NIOSH Pocket Guide to Chemical Hazards list the Glass following effects of overexposure to the chemicals/materials tabulated (Borosilicate) — 0-75 10 (3) 15 (3) below when they are inhaled, ingested, or contacted with skin or eye. Yttrium Vanadate 13566-12-6 0-<0.5 1.0 1.0  Lead: Ingestion and inhalation of lead dust or fume must be Aluminum Oxide 1344-28-1 0-<0.03 10 (3) 15.(3) avoided. Irritation of the eyes and respiratory tract may occur. (1) These chemicals are subject to the reporting requirements of section 313 of Excessive lead absorption is toxic and may include symptoms such Title III of the Superfund Amendments and Reauthorization Act of 1986 as anemia, weakness, abdominal pain and kidney disease. and 40 CFR Part 372.  Mercury: Exposure to high concentrations of vapors for brief (2) The mercury and lead in this product are substances known in the state of periods can cause acute symptoms such as pneumonitis, chest California to cause reproductive toxicity if ingested. [California Safe pains, shortness of breath, coughing, gingivitis, salivation and Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65).] possibly stomatitis. May cause redness and irritation as a result of (3) Limits as nuisance particulate. contact with the skin and/or eyes.  Quartz, Fused: Fibrosis of the lungs causing shortness of breath and coughing has been associated with silica exposure. Section 3. Hazards Identification  Glass: Glass dust is considered to be physiologically inert and as EMERGENCY OVERVIEW: such, has an OSHA exposure limit of 15 mg/cubic meter for total THERE ARE NO KNOWN HEALTH HAZARDS FROM dust and 5 mg/cubic meter for respirable dust. The ACGIH TLVs EXPOSURE TO BULBS THAT ARE INTACT. IF A BULB IS for particulates not otherwise classified are 10 mg/cubic meter for BROKEN, THE MATERIALS CITED IN SECTION 2 MAY BE total dust and 3 mg/cubic meter for respirable dust. RELEASED.  Yttrium Vanadate: Inhalation of vanadium compounds can cause Carcinogenic Assessment (NTP Annual Report, IARC Mono- irritation of the nose, throat, and respiratory tract. Eye contact and graphs, Other): None. prolonged, repeated skin contact may also cause irritation. Studies of workers exposed to this material showed no evidence of chronic Section 4. Physical Properties or systemic effects. Not applicable to intact bulbs.  Aluminum Oxide (Alumina): Alumina is a nontoxic material that is very low in free-silica content. Sharp-edged particles can irritate Section 5. Fire and Explosion Hazards the eyes, perhaps the skin, and definitely the mucous membranes of Flammability: Noncombustible. Fire-Extinguishing Materials: Use the respiratory tract. extinguishing agents suitable for surrounding fire. Special Fire- Fighting Procedure: Use a self-contained breathing apparatus to Section 8. Emergency and First-Aid Measures prevent inhalation of dust and/or fumes that might be generated from Glass Cuts: Normal first aid procedures. Seek medical attention as broken bulbs during fire-fighting activities. Unusual Fire and required. Inhalation: If discomfort, irritation or symptoms of Explosion Hazards: When exposed to high temperature, toxic fumes pulmonary involvement develop, remove from exposure and seek may be released from broken bulbs. SPECTRONICS CORPORATION BLE-100S/MR Bulb Effective: 1/25/07 PRODUCT SAFETY DATA SHEET Page 2 Supersedes: N/A medical attention. Ingestion: Seek medical attention. Contact, Skin: Thoroughly wash affected area with mild soap and water. If irritation occurs, seek medical attention. Contact, Eye: Wash eyes immediately, including under eyelid, with water for 15 minutes. Seek medical Eye Protection: OSHA-specified safety glasses, goggles or face shield attention. are recommended if lamps are being broken. In the event an outer jacket is broken, the lamps should be shut off and replaced to avoid exposure to ultraviolet radiation. Section 9. Stability and Reactivity Protective Clothing: OSHA-specified cut and puncture-resistant Stability: Stable. gloves are recommended for dealing with broken lamps. Conditions to Avoid: None for intact bulbs. Hygienic Practices: After handling broken lamps, wash thoroughly Incompatibility (Materials to Avoid: None for intact bulbs. before eating, smoking or handling tobacco products, applying cosmetics Hazardous Decomposition Products: None for intact bulbs. or using toilet facilities. Hazardous Polymerization Products: Will not occur. Section 12. Other Information Section 10. Disposal of Lamps USER’S RESPONSIBILITY: A bulletin such as this cannot be Cleanup: If lamps are broken, ventilate area where breakage occurred. expected to cover all possible individual situations. As the user has the Clean with a special mercury vacuum (not a standard vacuum) or other responsibility to provide a safe workplace, all aspects of an individual suitable means that avoids dust and mercury vapor generation. Take operation should be examined to determine if, or where, precautions (in usual precautions for collection of broken glass. addition to those described herein) are required. Any health hazard and Recycling: Mercury lamps can be recycled. For a list of lamp recyclers, safety information contained herein should be passed on to your and to obtain state regulatory disposal information, log onto customers or employees, as the case may be. www.lamprecycle.org. DISCLAIMER OF LIABILITY: The information contained herein is, Disposal: It is the responsibility of the waste generator to ensure proper to the best of our knowledge and belief, accurate. However, since the classification and disposal of waste products. TCLP tests should be conditions of handling and use are beyond our control, we make no conducted on all waste products, including this one, to determine the guarantee of results, and assume no liability for damages incurred by use ultimate disposition in accordance with applicable federal, state and local of this material. All chemicals may present unknown health hazards and regulations. should be used with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazards which exist. Section 11. Special Handling of Broken Lamps/ Final determination of suitability of the chemical is the sole Personal Protection responsibility of the user. No representations or warranties, either Ventilation: Use adequate general and local exhaust ventilation to expressed or implied, of merchantability, fitness for a particular purpose maintain exposure levels below the PEL or TLV limits. If such or any other nature are made hereunder with respect to the information ventilation is unavailable, use respirators as specified below. contained herein or the chemical to which the information refers. It is the Respiratory Protection: Use appropriate NIOSH-approved respirator responsibility of the users to comply with all applicable federal, state if airborne dust concentrations exceed the pertinent PEL or TLV limits. and local laws and regulations. All appropriate requirements set forth in 29 CFR 1910.134 should be met. A03184

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the BLE-100S/MR have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

UV LAMP, 1 x 365nm 6 Watt BLB Tube, Rechargeable Lantern, 6 Volt with AC Rechar

Bench Mounting Bracket

Bench Mount for FA-100

Spectronics Battery-operated Lamps

Spectronics Bench and Display Lamps

Concentrated Spot Bulb, 150 Watt (120 Volts)