Elite.Parts chervon right Manufacturers chervon right S chervon right SOLA/HEVI-DUTY chervon right T2H112S
About product Specifications Features Datasheet FAQ

SOLA/HEVI-DUTY T2H112S

Image of SOLA/HEVI-DUTY T2H112S

Description

Sola/Hevi-Duty T2H112S Low Voltage, 60 Hz, Three Phase General Purpose Transformer

Part Number

T2H112S

Price

Request Quote

Manufacturer

SOLA/HEVI-DUTY

Lead Time

Request Quote

Category

TRANSFORMERS

Specifications

Depth (Inches)

22

Design Style

1

Elec. Connection

21

Group

C

Height (Inches)

34

Hz

60

KVA

112.5

Mounting

Bracket Mount

NEMA 3R Weather Shield

WS-30

Phase

Three

Power Rating

112.5 KVA

Primary Amps

135

Primary Connection

Delta

Primary Voltage

480

Secondary Amps

313.0

Secondary Voltage

208Y/120

Ship Weight (Lbs.)

659

Type

Ventilated Transformer

Width (Inches)

28

Features

Datasheet

pdf file

T2H112S-580405962.pdf

496 KiB

Extracted Text

Ventilated Distribution Transformers 5 General Purpose Energy efficient dry-type transformers 600 Volt Class, isolation type, single and three phase, 15 kVA through 500 kVA. Indoor and outdoor models available. Accessories and Optional Design Styles • Electrostatic shield for quality power • Wall mounting brackets (500 lbs maximum) (Item WB1C) • Weather Shields (UL Listed/NEMA Type 3R) • Stainless Steel Enclosures • Totally enclosed non-ventilated designs (TENV) (Non UL) * • Open core and coil designs (UL Recognized) • Copper Wound designs E25872 • Low temperature designs • High efficiency for low cost operation • Compliant to NEMA TP-1 Standards Features • Single and three phase availability • UL Listed/NEMA Type 3R ventilated outdoor enclosures when used with optional weather shields • Fast delivery (order separately) • 10 year limited warranty • UL Class 220°C insulation system, 150°C temperature rise under full load Certifications and Compliances • Terminal board connections and spacious wiring • Listed compartment - UL 1561 • Panel enclosure design reduces labor time. Wiring diagram on inside front cover. Selection Tables: Single Phase Group 1: 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz Type 3R Design Elec Catalog Height Width Depth Approx. Ship Primary Secondary kVA 1 2 2 Number in (mm) in (mm) in (mm) Weight lbs (kg) Amps Amps Weather Shield Style Conn 15 28.00 (711.2) 16.00 (406.4) 16.00 (406.4) 210.0 (95.25) 1 1 62.5/31.3 125/62.5 ES5H15S WS-15 25 28.00 (711.2) 16.00 (406.4) 16.00 (406.4) 245.0 (111.13) 1 1 104/52.1 208/104 ES5H25S WS-15 37.5 31.00 (787.4) 18.00 (457.2) 18.00 (457.2) 340.0 (154.22) 1 1 156/78 313/156 ES5H37S WS-17 50 31.00 (787.4) 18.00 (457.2) 18.00 (457.2) 415.0 (188.24) 1 1 208/104 416/208 ES5H50S WS-17 75 44.00 (1117.6) 23.00 (584.2) 21.00 (533.4) 610.0 (276.69) 1 1 313/156 625/313 ES5H75S WS-09 100 44.00 (1117.6) 23.00 (584.2) 21.00 (533.4) 705.0 (319.78) 1 1 417/208 833/417 ES5H100S WS-09 167 46.00 (1168.4) 26.00 (660.4) 24.00 (609.6) 980.0 (444.52) 1 1 695/348 1392/695 ES5H167S WS-16 Group 2 – 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz Type 3R Design Elec Catalog Height Width Depth Approx. Ship Primary Amps Secondary kVA 1 2 2 Number Weather Shield in (mm) in (mm) in (mm) Weight lbs (kg) Style Conn @ 277 V Amps 15 28.00 (711.2) 16.00 (406.4) 16.00 (406.4) 215.0 (97.52) 1 2 54.2 125/62.5 ES12H15S WS-15 25 28.00 (711.2) 16.00 (406.4) 16.00 (406.4) 250.0 (113.40) 1 2 90.3 208/104 ES12H25S WS-15 Notes: 1. Weather shields (set of two) must be ordered separately. 2. Design Styles and Electrical Connections can be found at the end of the Ventilated Distribution Transformers section. * Not all optional designs are listed. Contact Technical Services. Contact Technical Services at (800) 377-4384 with any questions. 201 Visit our website at www.solahd.com. Ventilated Distribution Transformers 5 Selection Tables: Three Phase Group A: 480 Volt Δ Primary, 208/120 Secondary, 60 Hz Type 3R Design Elec Catalog Height Width Depth Approx. Ship Primary Secondary kVA 1 2 2 Number in (mm) in (mm) in (mm) Weight lbs (kg) Amps Amps Weather Shield Style Conn 3 ET2H15 15 23.00(584.2) 18.00 (457.2) 14.00 (355.6) 187.0 (84.82) 1 5 18.1 41.7 WS-02 ET2H15S 3 ET2H30 30 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 292.0 (132.45) 1 5 36.1 83.4 WS-14 ET2H30S 3 ET2H45 45 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 376.0 (170.55) 1 5 54.2 125.0 WS-14 ET2H45S 3 ET2H75 75 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 569.0 (258.09) 1 5 90.3 208.0 WS-30 ET2H75S 112.5 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 768.0 (348.36) 1 5 135.0 313.0 ET2H112S WS-30 150 ET2H150S WS-10 44.00 (1117.6) 33.00 (838.2) 21.00 (533.4) 933.0 (423.20) 1 5 181.0 417.0 225 ET2H225S WS-11 46.00 (1168.4) 36.00 (914.4) 24.00 (609.6) 1342.0 (608.72) 1 5 271.0 625.0 300 ET2H300S WS-11 46.00 (1168.4) 36.00 (914.4) 24.00 (609.6) 1525.0 (691.73) 1 5 361.0 834.0 500 ET2H500S WS-12 65.00 (1651.0) 45.00 (1143.0) 35.00 (889.0) 2460.0 (1115.84) 1 5 602.0 1390.0 4 Group B: 480 Volt Δ Primary, 240 Volt Δ, Secondary with reduced capacity center tap , 60 Hz Type 3R Design Elec Catalog Height Width Depth Approx. Ship Primary Secondary kVA 1 2 2 Number in (mm) in (mm) in (mm) Weight lbs (kg) Amps Amps Weather Shield Style Conn 3 ET5H15 15 23.00 (584.2) 19.00 (482.6) 14.00 (355.6) 189.0 (85.73) 1 6 18.1 36.1 WS-02 ET5H15S 3 ET5H30 30 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 292.0 (132.45) 1 6 36.1 72.3 WS-14 ET5H30S 3 ET5H45 45 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 381.0 (172.82) 1 6 54.2 108.0 WS-14 ET5H45S 3 ET5H75 75 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 560.0 (254.01) 1 6 90.3 181.0 WS-30 ET5H75S 112.5 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 760.0 (344.73) 1 6 135.0 271.0 ET5H112S WS-30 150 44.00 (1117.6) 33.00 (838.2) 21.00 (533.4) 940.0 (426.38) 1 6 181.0 361.0 ET5H150S WS-10 225 46.00 (1168.4) 36.00 (914.4) 24.00 (609.6) 1342.0 (608.72) 1 6 271.0 542.0 ET5H225S WS-11 300 46.00 (1168.4) 36.00 (914.4) 24.00 (609.6) 1525.0 (691.73) 1 6 361.0 723.0 ET5H300S WS-11 500 65.00 (1651.0) 45.00 (1143.0) 35.00 (889.0) 2460.0 (1115.84) 1 6 602.0 1204.0 ET5H500S WS-12 Notes: 1. Weather shields (set of two) must be ordered separately. 2. Design Styles and Electrical Connections can be found at the end of the Ventilated Distribution Transformers section. 3. Unshielded model. 4. Refer to Capacity of Center Tap in Center Tap Delta Transformers at the beginning of this section. Contact Technical Services at (800) 377-4384 with any questions. 202 Visit our website at www.solahd.com. Ventilated Distribution Transformers 5 Selection Tables: Three Phase Group C: 480 Volt Δ Primary, 480Y/277 Secondary, 60 Hz Catalog Type 3R Height Width Depth Approx. Ship Design Elec Primary Secondary kVA 1 2 2 Number Weather Shield in (mm) in (mm) in (mm) Weight lbs (kg) Style Conn Amps Amps 15 23.00 (584.2) 18.00 (457.2) 14.00 (355.6) 189.0 (85.73) 1 8 18.1 18.1 ET81H15S WS-02 30 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 295.0 (133.81) 1 8 36.1 36.1 ET81H30S WS-14 45 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 380.0 (172.37) 1 8 54.2 54.2 ET81H45S WS-14 75 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 560.0 (254.01) 1 8 90.3 90.3 ET81H75S WS-30 112.5 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 780.0 (353.80) 1 8 135.0 135.0 ET81H112S WS-30 150 44.00 (1117.6) 33.00 (838.2) 21.00 (533.4) 933.0 (423.20) 1 8 181.0 181.0 ET81H150S WS-10 225 ET81H225S WS-11 46.00 (1168.4) 36.00 (914.4) 24.00 (609.6) 1342.0 (608.72) 1 8 271.0 271.0 300 46.00 (1168.4) 36.00 (914.4) 24.00 (609.6) 1525.0 (691.73) 1 8 361.0 361.0 ET81H300S WS-11 500 65.00 (1651.0) 45.00 (1143.0) 35.00 (889.0) 2460.0 (1115.84) 1 8 602.0 602.0 ET81H500S WS-12 Group D: 208 Volt Δ Primary, 480Y/277 Secondary, 60 Hz Catalog Type 3R Height Width Depth Approx. Ship Design Elec Primary Secondary kVA 1 2 2 Number Weather Shield in (mm) in (mm) in (mm) Weight lbs (kg) Style Conn Amps Amps 15 23.00 (584.2) 18.00 (457.2) 14.00 (355.6) 195.0 (88.45) 1 10 41.7 18.1 ET84H15S WS-02 30 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 295.0 (133.81) 1 10 83.4 36.1 ET84H30S WS-14 45 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 375.0 (170.09) 1 10 125.0 54.2 ET84H45S WS-14 75 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 570.0 (258.55) 1 10 208.0 90.3 ET84H75S WS-30 112.5 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 780.0 (353.80) 1 10 313.0 135.0 ET84H112S WS-30 150 44.00 (1117.6) 33.00 (838.2) 21.00 (533.4) 972.0 (440.89) 1 10 417.0 181.0 ET84H150S WS-10 Notes: 1. Weather shields (set of two) must be ordered separately. 2. Design Styles and Electrical Connections can be found at the end of the Ventilated Distribution Transformers section. Contact Technical Services at (800) 377-4384 with any questions. 203 Visit our website at www.solahd.com. Ventilated Distribution Transformers 5 Selection Tables: Three Phase Group E: 208 Volt Δ Primary, 208Y/120 Secondary, 60 Hz Type 3R Design Elec Catalog Height Width Depth Approx. Ship Primary Secondary kVA 1 2 2 Number in (mm) in (mm) in (mm) Weight lbs (kg) Amps Amps Weather Shield Style Conn 15 23.00 (584.2) 18.00 (457.2) 14.00 (355.6) 190.0 (86.18) 1 9 41.7 41.7 ET3H15S WS-02 30 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 295.0 (133.81) 1 9 83.4 83.4 ET3H30S WS-14 45 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 380.0 (172.37) 1 9 125.0 125.0 ET3H45S WS-14 75 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 570.0 (258.55) 1 9 208.0 208.0 ET3H75S WS-30 112.5 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 805.0 (365.14) 1 9 313.0 313.0 ET3H112S WS-30 150 44.00 (1117.6) 33.00 (838.2) 21.00 (533.4) 972.0 (440.89) 1 9 416.0 416.0 ET3H150S WS-10 Group F: 240 Volt Δ Primary, 208Y/120 Secondary, 60 Hz Type 3R Design Elec Catalog Height Width Depth Approx. Ship Primary Secondary kVA 1 2 2 Number in (mm) in (mm) in (mm) Weight lbs (kg) Amps Amps Weather Shield Style Conn 15 23.00 (584.2) 18.00 (457.2) 14.00 (355.6) 190.0 (86.18) 1 11 36.1 41.7 ET6H15S WS-02 30 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 295.0 (133.81) 1 11 72.3 83.4 ET6H30S WS-14 45 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 380.0 (172.37) 1 11 108.0 125.0 ET6H45S WS-14 75 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 570.0 (258.55) 1 11 181.0 208.0 ET6H75S WS-30 112.5 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 805.0 (365.14) 1 11 271.0 313.0 ET6H112S WS-30 150 44.00 (1117.6) 33.00 (838.2) 21.00 (533.4) 972.0 (440.89) 1 11 361.0 417.0 ET6H150S WS-10 Group G: 240 Volt Δ Primary, 480Y/277 Secondary, 60 Hz Catalog Type 3R Height Width Depth Approx. Ship Design Elec Primary Secondary kVA 1 2 2 Number in (mm) in (mm) in (mm) Weight lbs (kg) Amps Amps Weather Shield Style Conn 15 23.00 (584.2) 18.00 (457.2) 14.00 (355.6) 190.0 (86.18) 1 12 36.1 18.1 ET85H15S WS-02 30 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 295.0 (133.81) 1 12 72.3 36.1 ET85H30S WS-14 45 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 380.0 (172.37) 1 12 108.0 54.2 ET85H45S WS-14 75 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 560.0 (254.01) 1 12 181.0 90.3 ET85H75S WS-30 112.5 ET85H112S WS-30 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 805.0 (365.14) 1 12 271.0 135.0 150 44.00 (1117.6) 33.00 (838.2) 21.00 (533.4) 972.0 (440.89) 1 12 361.0 181.0 ET85H150S WS-10 Notes: 1. Weather shields (set of two) must be ordered separately. 2. Design Styles and Electrical Connections can be found at the end of the Ventilated Distribution Transformers section. Contact Technical Services at (800) 377-4384 with any questions. 204 Visit our website at www.solahd.com. Ventilated Distribution Transformers 5 Selection Tables: Three Phase Group J: 480 Volt Δ Primary, 380Y/220 Secondary, 60 Hz Type 3R Design Elec Catalog Height Width Depth Approx. Ship Primary Secondary kVA 1 2 2 Number in (mm) in (mm) in (mm) Weight lbs (kg) Amps Amps Weather Shield Style Conn 15 23.00 (584.2) 18.00 (457.2) 14.00 (355.6) 190.0 (86.18) 1 7 18.1 22.8 ET79H15S WS-02 30 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 295.0 (133.81) 1 7 36.1 45.6 ET79H30S WS-14 45 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 380.0 (172.37) 1 7 54.2 68.4 ET79H45S WS-14 75 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 360.0 (163.29) 1 7 90.3 114.0 ET79H75S WS-30 112.5 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 770.0 (349.27) 1 7 135.3 170.9 ET79H112S WS-30 150 44.00 (1117.6) 33.00 (838.2) 21.00 (533.4) 933.0 (423.20) 1 7 180.4 227.9 ET79H150S WS-10 Group K: 480 Volt Δ Primary, 208Y/120 Secondary, 60 Hz, Copper-Wound Type 3R Design Elec Catalog Height Width Depth Approx. Ship Primary Secondary kVA 1 2 2 Number in (mm) in (mm) in (mm) Weight lbs (kg) Amps Amps Weather Shield Style Conn 15 23.00 (584.2) 18.00 (457.2) 14.00 (355.6) 205.0 (92.98) 1 5 18.1 41.7 ET2H15SCu WS-02 30 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 305.0 (138.35) 1 5 36.1 83.4 ET2H30SCu WS-14 45 28.00 (711.2) 23.00 (584.2) 16.00 (406.4) 405.0 (183.70) 1 5 54.2 125.0 ET2H45SCu WS-14 75 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 535.0 (242.67) 1 5 90.3 208.0 ET2H75SCu WS-30 112.5 34.00 (863.6) 28.00 (711.2) 22.00 (558.8) 805.0 (365.14) 1 5 135.0 313.0 ET2H112SCu WS-30 150 44.00 (1117.6) 33.00 (838.2) 21.00 (533.4) 972.0 (440.89) 1 5 181.0 417.0 ET2H150SCu WS-10 225 46.00 (1168.4) 36.00 (914.4) 24.00 (609.6) 1325.0 (601.01) 1 5 271.0 625.0 ET2H225SCu WS-11 300 46.00 (1168.4) 36.00 (914.4) 24.00 (609.6) 1515.0 (687.19) 1 5 361.0 834.0 ET2H300SCu WS-11 500 65.00 (1651.0) 45.00 (1143.0) 35.00 (889.0) 2460.0 (1115.84) 1 5 602.0 1390.0 ET2H500SCu WS-12 Notes: 1. Weather shields (set of two) must be ordered separately. 2. Design Styles and Electrical Connections can be found at the end of the Ventilated Distribution Transformers section. Contact Technical Services at (800) 377-4384 with any questions. 205 Visit our website at www.solahd.com. Ventilated Distribution Transformers 5 Design Style W D H Style 1 - Ventilated Contact Technical Services at (800) 377-4384 with any questions. 211 Visit our website at www.solahd.com. Ventilated Distribution Transformers 5 Electrical Connections (Single Phase) 240 x 480 Volt Primary, 120/208/240/277 Volt Primary, 120/240 Volt Secondary 120/240 Volt Secondary Taps: None Taps: 2, 2½% FCAN; 4, 2½% FCBN 1 2 H1 H2 H1 H2 5 3 1 2 4 6 7 5 3 1 2 4 6 8 SHIELD SHIELD X1 X3 X2 X4 X1 X3 X2 X4 Connect Primary Voltage Interconnect Connect Lines To Primary Voltage Interconnect Lines To 277 1 to 2 H1 & H2 504 1 to 2 H1 & H2 240 3 to 4 H1 & H2 492 2 to 3 H1 & H2 208 5 to 6 H1 & H2 480 3 to 4 H1 & H2 H1 to 4 120 H1 & H2 468 4 to 5 H1 & H2 H2 to 3 456 5 to 6 H1 & H2 Secondary Connect Interconnect Voltage Lines To 444 6 to 7 H1 & H2 240 X2 to X3 X1 & X4 432 7 to 8 H1 & H2 X2 to X3 252 H1 to 2 H2 to 1 H1 & H2 120-0-120 X1-X2-X4 X2 to 240 H1 to 4 H2 to 3 H1 & H2 X1 to X3 120 X1 & X4 228 H1 to 6 H2 to 5 H1 & H2 X2 to X4 216 H1 to 8 H2 to 7 H1 & H2 ES12 Series Secondary Connect Interconnect Voltage Lines To 240 X2 to X3 X1 & X4 Electrical Connections (Three Phase) 120-0-120 X1-X2-X4 X2 to X3 X2 to 480 Δ Volt Primary, 480 Δ Volt Primary, 120 X1 to X3 X2 to X4 X1 & X4 208Y/120 Volt Secondary 240 Δ W/120 CT Volt Secondary 6 5 ES5 Series Taps: 2, 2½% FCAN; 4, 2½% FCBN Taps: 2, 2½% FCAN; 4, 2½% FCBN H1 H2 H3 H1 H2 H3 7654321 7654321 7654321 7654321 7654321 7654321 SHIELD SHIELD * * X0 X1 X2 X3 X6 X1 X2 X3 H2 X2 X2 H2 X1 X0 H1 H3 X1 X3 H1 H3 X3 X6 Primary H1-H2-H3 Secondary Voltage Primary H1-H2-H3 Secondary Voltage @ Tap Voltage X1, X2, X3 X0- X1, X2, X3 @ Tap Voltage X1, X2, X3 X6-X1, X6-X3 1 504 1 504 2 492 2 492 3 480 3 480 4 468 208 120 4 468 240 120 5 456 5 456 6 444 6 444 7 432 7 432 ET2 and 3H Series ET5 Series * Shield available in electrostatically shielded units only. * Shield available in electrostatically shielded units only. Contact Technical Services at (800) 377-4384 with any questions. 212 Visit our website at www.solahd.com. Ventilated Distribution Transformers 5 Electrical Connections (Three Phase) cont. 480 Δ Volt Primary 480 Δ Volt Primary 208 Δ Volt Primary 380/220 Volt Secondary 480Y/277 Volt Secondary 208Y/120 Volt Secondary 8 7 9 Taps: 2, 2½% FCAN; 4, 2½% FCBN Taps: 2, 2½% FCAN; 4, 2½% FCBN Taps: 2, 2½% FCAN; 4, 2½% FCBN H1 H2 H3 H1 H2 H3 H1 H2 H3 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 SHIELD SHIELD SHIELD X0 X1 X2 X3 X0 X1 X2 X3 X0 X1 X2 X3 X2 X2 X2 H2 H2 H2 X1 X0 X1 X0 X1 X0 H1 H3 X3 H1 H3 X3 H1 H3 X3 Primary H1-H2-H3 Secondary Voltage Primary H1-H2-H3 Secondary Voltage Primary H1-H2-H3 Secondary Voltage @ Tap Voltage X1, X2, X3 X0- X1, X2, X3 @ Tap Voltage X1, X2, X3 X0- X1, X2, X3 @ Tap Voltage X1, X2, X3 X0- X1, X2, X3 1 504 1 504 1 218 2 492 2 492 2 213 3 480 3 480 3 208 4 468 380 220 4 468 480 277 4 203 208 120 5 456 5 456 5 198 6 444 6 444 6 192 7 432 7 432 7 187 ET79 Series ET81 Series ET3 Series 208 Δ Volt Primary 240 Δ Volt Primary 240 Δ Volt Primary 480Y/277 Volt Secondary 208Y/120 Volt Secondary 480Y/277 Volt Secondary 10 11 12 Taps: 2, 2½% FCAN; 4, 2½% FCBN Taps: 2, 2½% FCAN; 4, 2½% FCBN Taps: 2, 2½% FCAN; 4, 2½% FCBN X1 X2 X3 H1 H2 H3 X1 X2 X3 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 7654321 SHIELD SHIELD SHIELD H0 H1 H2 H3 H0 H1 H2 H3 X0 X1 X2 X3 H2 H2 X2 X2 X2 H2 H1 H0 H1 H0 X1 X0 X1 X3 X1 X3 H3 H3 H3 X3 H1 Primary X1-X2-X3 Secondary Voltage Primary H1-H2-H3 Secondary Voltage Primary X1-X2-X3 Secondary Voltage @ Tap Voltage H1-H2-H3 H0-H1, H2, H3 @ Tap Voltage X1, X2, X3 X0- X1, X2, X3 @ Tap Voltage H1, H2, H3 H0- H1, H2, H3 1 252 1 218 1 252 2 213 2 246 2 246 3 240 3 208 3 240 4 234 480 277 4 203 480 277 4 234 208 120 5 228 5 198 5 228 6 222 6 192 6 222 7 216 7 187 7 216 ET85 Series ET84 Series ET6 Series Contact Technical Services at (800) 377-4384 with any questions. 213 Visit our website at www.solahd.com.

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the T2H112S have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

112.5 KVA K-13 Rated Transformer 3 Phase

product

Sola/Hevi-Duty E200 Encapsulated/PC Board Transformer

product

Three phase transformer, low voltage, 480 volt delta primary, 380 Y/220 secondary, 9 KVA; 10.8 prima...

product

Sola/Hevi-Duty T2H150S Transformer - Three phase transformer, low voltage, 480 volt delta primary, 2...

product

Sola/Hevi-Duty T5H112S Transformers - Three phase transformer, low voltage, 480 volt delta primary, ...

product

Sola/Hevi-Duty T5H15S Transformer -Distribution Transformer