Elite.Parts Manufacturers S SOLA/HEVI-DUTY SDN 5-24-100C
About product Specifications Features Datasheet FAQ

SOLA/HEVI-DUTY SDN 5-24-100C

Image of SOLA/HEVI-DUTY SDN 5-24-100C

Description

SOLA/HEVI-DUTY SDN 5-24-100C SDN-C DIN rail power supply - Series:SDN, Output Voltage:24V, Output Power Max:120W, Output Current:5A, Number of Outputs:1, External Depth:4.55", External Height:4.88", External Width:1.94", Output Voltage Max:28.5V RoHS Compliant: Yes

Part Number

SDN 5-24-100C

Price

Request Quote

Manufacturer

SOLA/HEVI-DUTY

Lead Time

Request Quote

Category

PRODUCTS - S

Specifications

AC Range

85 - 264 Vac

Approvals

UL508 Listed, cULus; UL 60950-1, cURus; IEC60950-1; Class I, Div. 2, Hazadous location approval; CE (LVD 73/23 & 2004/108/EC)

Case

Fully enclosed

Connections(input)

Screw terminals

Connections(output)

Two terminals per output

connector size range(input)

16-10 AWG (1.5-6 mm2) for solid conductors

connector size range(output)

16-10 AWG (1.5-6 mm2) for solid conductors

Current Limit

PowerBoost

DC Range

90 - 375 Vdc

Efficiency

> 90% typ. (12 W)

EMC

EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2

Free Space

15 mm in front, 25 ~ 40 mm above and below, 10 mm left and right

Frequency

43-67 Hz

Fusing(input)

Internally fused

Fusing(output)

Outputs are capable of providing high currents for short periods of time for inductive load startup or switching.Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated.Continuous current overload allows for reliable fuse tripping

General Protection/Safety

Protected against continuous short -circuit, continuous overload, continuous open circuit.Protection Class 1 (IEC536), degree of protection IP20 (IEC60529) Safe low voltage: SELV (acc. IEC60950-1)

H x W x D (inches/mm)

4.88 × 1.97 × 4.55 (124 × 50 × 116)

Holdup Time

>20 ms

Immunity

EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11, IEC 61000-4-34 voltage dip immunity standard

Initial Voltage Setting

24.5V ± 1%

Inrush current max.

Typ.

Mounting

Simple snap-on to DIN TS35/7.5 or TS35/15 rail system

MTBF

> 550,000 hrs

Nominal current

1.65 - 0.55 A

Nominal Voltage(Input)

115/230 Vac

Nominal Voltage(output)

24 V (23.5~28.5 Vdc Adj.)

Overvoltage Protection

> 30.5 but

Parallel Operation

Switch selectable single unit or parallel unit operation. Units will not be damaged by parallel operation (regardless of switch position setting)

PARD

(Periodic and Random Deviation)100 mV peak-peak max

Peak Current

1.5 × Nominal Current for 2 seconds minimum while holding voltage > 20 Vdc

Power Back Immunity

5 A (120 W)

Power Factor Correction

Active power factor correction to better than 0.92

Short Circuit Current

1.5 x Nominal Current at near zero volts at short circuit condition

Status Indicators

Visual: 3 status LEDs/Relay: N.O. contact rated 200ma/50 Vdc

Temperature

-40oC to + 85oC/Operation -25oC to +60oC full power, with linear derating to half power from 60 to 70oC

Warranty

5 years

Weight

(lbs/kg) 1.65 (0.75)

Features

Datasheet

pdf file

SOLAHEVI-DUTY- SDN 5-24-100C-DS-5610418891.pdf

411 KiB

Extracted Text

Power Supplies 4 SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs to offer the most performance available from SolaHD. Essential industrial features such as Sag Immunity, Power Factor Correction, and universal voltage input have been retained in this series. Wide temperature operating range and parallel operation capability make the new SDN-C units suitable to a variety of industrial applications. Features • Compact packaging to save space on the DIN rail • New visual diagnostic LEDs for input and output status at a glance • High MTBF means high reliability and long life • Higher efficiency saves energy and lowers amount of heat generated in panel TM • PowerBoost overload capability to start high UL 60950 EMC and inrush loads UL 508 Listed E137632 Low Volt. IND. CONT. EQ. Related Products CUL/CSA-C22.2 Directive E61379 • Accepts Universal voltage 85-264 Vac, 50/60 Hz input No. 234-M90 • SDN-P series • Single phase models meet SEMI F47 Sag Immunity TM • SDP series standard • SFL series • Power Factor Correction (meets EN61000-3-2) • SCP series • Class I, Div. 2 Hazardous Locations – ATEX approval (pending) • SDU UPS – Single and three-phase input available Applications • Patented DIN rail mounting clip • Industrial Machine Control • User Adjustable output voltage accessible via front face • Process Control • Parallel capability standard • Conveying Equipment • Industrial grade design o o • Material Handling – -25 C to 60 C operation without derating – Rugged metal case and DIN connector • Vending Machines • User-friendly • Packaging Equipment – LEDs for status • Amusement Park Equipment – Large, rugged, accessible screw terminals • Semiconductor Fabrication Equipment – Easy on/off DIN mounting TM • DeviceNet • Fully tested and burned-in at factory • RoHS compliant Accessories • Chassis Mount Bracket (SDN-PMBRK2) Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 101 Power Supplies 4 The SolaHD Difference Rugged metal packaging Multiple output connections for ease of wiring multiple devices Large, IP20-rated, screw 2 terminals for #10 AWG/4 mm , for quick, easy installation New visual diagnostic LEDs show input and output status (see table below) DC OK Relay Single or parallel use selectable by user Adjustable output voltage Clearly labeled front panel No internal fan, no extra cooling required in any power level UL508 listing means no derating in UL 508 systems Full CE compliance for safety, emissions and Automatically adjusts for global ingress protection Input voltages. No manual intervention required. New narrow width saves panel space LED Light Status Conditions Normal AC Power Loss AC Input Low No DC High Load Overload Hot Too Hot Green - Yellow Green Green Green Green Green Input Green - Green - Yellow Yellow Green - Output - - - Red Yellow Red Yellow Yellow Alarm Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 102 Power Supplies 4 SDN-C Specifications (Single Phase) Catalog Number Description SDN 5-24-100C SDN 10-24-100C SDN 20-24-100C Input 115/230 Vac Nominal Voltage -AC Range 85 - 264 Vac 1 90 - 375 Vdc -DC Range -Frequency 43-67 Hz 2 Nominal Current 1.65 - 0.55 A 3.2 - 1.0 A 6A / 3A Typ. < 15 A Typ.< 30 A < 40 A -Inrush current max. 3 > 90% typ. (12 W) > 90% typ. (24 W) > 92% (38 W) Efficiency (Losses ) Active power factor correction to better than 0.92 Power Factor Correction Output 24 V (23.5~28.5 Vdc Adj.) Nominal Voltage < ±2 % overall (combination Line, load, time and temperature related changes) -Tolerance 24.5V ± 1% Initial Voltage Setting 4 < 50 mVpp <100mVpp -Ripple PARD (Periodic and Random Deviation) = 100 mV peak-peak max PARD Overvoltage Protection > 30.5 but < 33 Vdc, auto recovery < 35V Power Back Immunity 5 A (120 W) 10 A (240 W) 20 A (480W) Nominal Current 5 1.5 × Nominal Current for 2 seconds minimum while holding voltage > 20 Vdc -Peak Current -Short Circuit Current 1.5 x Nominal Current at near zero volts at short circuit condition PowerBoost™ -Current Limit Switch selectable single unit or parallel unit operation. Units will not be damaged by parallel operation (regardless of switch position setting). Parallel Operation >20 ms (Full load, 100 Vac Input @ T =+25°C) to 95% output voltage Holdup Time amb <150 mS from 95% to 10% rated voltage @ full load (T =+25°C) Voltage Fall Time amb < 0.5% Line and Load Regulation General EMC: EN61000-6-2:2001, EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2 -Emissions EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input -Immunity and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11, IEC 61000-4-34 voltage dip immunity standard UL508 Listed, cULus; UL 60950-1, cURus; IEC60950-1; Class I, Div. 2, Hazadous location approval; CE (LVD 73/23 & 2004/108/EC), Approvals (EMC 89/336 & 93/68/EEC); EN61000-3-2 o o o o o Storage: -40 C to + 85 C, Operation -25 C to +60 C full power, with linear derating to half power from 60 to 70 C (Convection cooling, 7 Temperature no forced air required). Operation up to 50% load permissible with sideways or front side up mounting orientation. 6 > 550,000 hrs > 450,000 hrs MTBF 5 Years Warranty Protected against continuous short -circuit, continuous overload, continuous open circuit. General Protection/Safety Protection Class 1 (IEC536), degree of protection IP20 (IEC60529) Safe low voltage: SELV (acc. IEC60950-1) Visual: 3 status LEDs (Input, Output, Alarm) Status Indicators Relay: N.O. contact rated 200ma/50 Vdc Installation Fusing Internally fused -Input Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for -Output wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Mounting 2 Input: Screw terminals, connector size range: 16-10 AWG (1.5-6 mm ) for solid conductors. Connections 2 Output: Two terminals per output, connector size range: 16-10 AWG (1.5-6 mm ) for solid conductors. Fully enclosed metal housing with fine ventilation grid to keep out small parts. Case 15 mm in front, 25 ~ 40 mm above and below, 10 mm left and right. -Free Space 4.88 × 1.97 × 4.55 (124 × 50 × 116) 4.88 × 2.36 × 4.55 (124 × 60 × 116) 4.88 x 3.42 x 4.98 (124 x 87 x 126.6) H x W x D (inches/mm) 1.65 (0.75) 1.98 (0.9) 2.6 (1.2) Weight (lbs/kg) 4. Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth 1. Not UL listed for DC input. scope and 50 Ohm resistor. 2. Input current ratings are conservatively specified with low input, worst case 5. Peak current is calculated at 24 Volt levels. efficiency and power factor. 6. Demonstrated through extended life test. 3. Losses are heat dissipation in watts at full load, nominal input line. o 7. Contact tech support for operation at -25 C. Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 103 Power Supplies 4 SDN-C Specifications (Three Phase) Catalog Number Description SDN 20-24-480CC SDN 40-24-480C Input Nominal Voltage 380 - 480 Vac 1 Two-phase input Yes 2 -AC Range Continuous 320 - 540 Vac -DC Range Continuous 450 - 760 Vdc TBD 3 -DC Range Short Term 420 - 780 Vdc TBD -Frequency 50 - 60 Hz 4 3 x 0.9 A or 2 x 1.3 A 3 x 1.6 A Nominal Current Negligible Negligible -Inrush Current Max. 5 93% (42 W) 94% (78 W) Efficiency (Losses ) Power Factor Correction Active Power Factor Correction Output Turn on Time Typ. 1s < 100mS full resistance load (T =+25°C) Voltage Rise Time amb Power Back Immunity < 35V Overvoltage Protection > 30.5 but < 33 Vdc, auto recovery Nominal Voltage 24V (24-28Vdc Adjustable) < ± 2% overall Voltage Regulation 24.5V ± 1% Initial Voltage Setting 6 < 100mVpp -Ripple PARD (Periodic and Random Deviation) = 200mV peak-peak max PARD 20 A (480 W) (constant power, not constant) 40 A (960 W) Nominal Current 7 1.5 × Nominal Current for 4 seconds minimum while holding voltage > 20 Vdc -Peak Current PowerBoost™ -Current Limit typ. 24W/°C typ. 48 W/°C Derating (T amb=60-70 °C) >20 ms >15 ms Holdup Time <50 mS from 95% to 10% rated voltage @ full load (T =+25°C) Voltage Fall Time amb Single or parallel operation selectable via front switch. For redundant 8 SDN 40 uses active paralleling Parallel Operation operation, use of external diode module is preferred General Fully enclosed metal housing with fine ventilation grid to keep out small parts. Case 70mm above and below, 10mm left and right (same as manual) 70mm above and below, 15mm in front, 25mm left & right Min. Required Free Space 4.85 x 2.56 x 4.68 (123.3 x 85 x 118.8) 4.85 x 7.09 x 4.85 (123.3 x 180 x 123.17) Max. Dimensions HxWxD (in/mm) 2.8 lb (1300 g) 5.3 lb (2400 g) Weight (lbs/g) EN61000-6-3:2001, Class B EN55011, EN55022 Radiated and Conducted including Annex. A, EN61000-3-2 EMC: -Emissions EN61000-6-1:2001, EN61000-6-2:2001, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and -Immunity level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11, Semi F47 sag immunity UL508 Listed, cULus; UL60950-1, cURus; IEC60950-1; ISA 12.12.01 Class 1 Div 2, Approvals CE (LVD 73/23 & 2004/108/EC), (EMC 89/336 & 93/68/EEC); EN61000-3-2,EN 60079-15 (Class 1, Zone 2) Storage: -40°C to + 85°C, Operation -25°C to +60°C full power, with linear derating to half power from 60°C to 70°C (Convection Temperature cooling, no forced air required). Operation up to 50% load permissible with sideways or front side up mounting orientation. < 90% RH, noncondensing; IEC 60068-2-2, 68-2-3 Humidity 0 to 3000 meters (0 to 10,000 feet) Altitude 2.5(g) RMS, 10-2000 Hz (random); three axes for 20 minutes each - IEC 60068-2-6 Vibration 3(g) peak, three axes, 11mseconds for each axis - IEC 60068-2-27 Shock 5 Years Warranty > 550,000 hrs MTBF (Nominal voltage, full load, T ambient = 25°C MTBF Protected against short -circuit, overload, open circuit. Protection class 1 (IEC536), General Protection/Safety degree of protection IP20 (IEC 529), Safe low voltage: SELV (acc. EN60950) LED Alarm, Output shutdown with automatic restart Over-Temperature Protection Status Indicators Visual: 3 status LEDs (Input, Output, Alarm); Relay: SSR or dry relay contact, signal active when Vout = 18.5Vdc = +/-5% Installation Externally fused Fusing: -Input Not fused. Output is capable of providing high currents (PowerBoost) for motor load startup. -Output Simple snap-on to DIN TS35/7.5 or TS35/15 rail system. Mounting Unit should handle normal shock and vibration of industrial use and transportation without falling off the rail. Input: screw terminals, Wiring for the connector will be ground on the left (when looking at the front of the unit), connector size range: 9 2 Connections 16-10AWG (1.5-6mm ) for solid conductors. Output: connector size range, wire gauge 6-7 AWG for SDN40; 2 all other models: 16-10AWG (1.5-6mm ) for solid conductors. The connector color will be gray or off-white. 1. SDN20 will operate at 75% load and SDN40 will operate at 50% load under loss of scope and 50 Ohm resister. 1 phase. Units will shut down if thermal threshold is exceeded under this condition. 7. SDN 20 and SDN 40 unit will go to HICCUP mode. SDN 5 and SDN 10 will maintain 2. Unit passed input voltage overstress test at 600 Vac maximum without failure. min 4 secs to deliver 150% load then drops to almost zero V out. The output voltage 3. DC operation will require the user to provide the proper input circuit protection. will immediately drop to almost zero when load rises above 150%. 4. Input current ratings are specified with low input, line conditions, worst case 8. All models except the 40amp unit are capable of parallel operation by use of a jumper efficiency values and power factor spikes. Input current at nominal input settings will pin, accessible by the end user. 40amp has current sharing signal. be typically half these values. 9. SDN40-24-480 only = Output signaling terminal block features (Shut down, Power 5. Losses are heat dissipation in watts at full load, nominal line. Good, Current Monitor, Current Balance, signal GND). 6. Ripple/noise is stated as typical values when measured with a 20 MHZ, bandwidth Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 104 Power Supplies 4 SDN-C Series Dimensions W D Dimensions - inches (mm) Catalog Number H W D + + - - 24VDC/2.5A OK 4.88 (124) 1.97 (50) 4.55 (116) SDN 5-24-100C OK NECClass2 PowerSupply 24-28V 4.88 (124) 2.36 (60) 4.55 (116) SDN 10-24-100C Single Parallel 4.88 (124) 3.42 (87) 4.98 (126.6) SDN 20-24-100C S O L A 4.85 (123) 2.56 (85) 4.68 (118.8) SDN 20-24-480CC PowerSupply SDN2.5-24-100P SDN5-24-100C ���� ���� �� ���� U C US LISTED L 115/230VAC 1.3-0.7A50/60HZ N L W D S O L A PowerSupply SDN20-24-480C ���� ���� �� ���� U C L US LISTED Input: Output: 3PH380/500VAC 24VDC/20A 1.7/1.5A/Phase50/60Hz Electronicallyprotected 24- L1 L2 L3 + + - - 28V Dimensions - inches (mm) Catalog Number H W D 4.85 (123) 7.09 (180) 4.85 (123) SDN 40-24-480C Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 105 SingleUse Par allelUse ContinuousMode FuseMode Resetfusemode Overload OK H H Power Supplies 4 SDN-C Series Mounting (cont.) Chassis Mounting Dimensions Instead of snapping a Sola SDN™ unit on the DIN Rail, you can also attach it using the screw mounting set SDN-PMBRK2. This set consists of two metal brackets, which replace the existing two aluminum profiles. SDN-C Series Mounting Detachment from DIN Rail: DIN Rail Mounting Snap on the DIN Rail: 1. Tilt unit slightly backwards 2. Put it onto the DIN Rail 3. Push downwards until stopped 4. Push at the lower front edge to lock 5. Shake the unit slightly to ensure that the retainer has locked Alternative Panel Mount: Using the optional SDN-PMBRK2 accessory, the unit can be screw mounted to a panel. Visit our website at www.solahd.com or contact Technical Services at (800) 377-4384 with any questions. 106

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the SDN 5-24-100C have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

SOLA/HEVI-DUTY SLD-15-3030-15T Power Supply - 15 V @ 3 A# Output 1, -15 V @ 3 A# Output 2, L3 Case

product

SOLA/HEVI-DUTY SLS-05-030-1T Power Supply - 5 V @ 3 A*# Output 1, A" Case

product

SOLA/HEVI-DUTY SLS-05-090-1T Power Supply - 5 V @ 9 A*# Output 1, C" Case

product

SOLA/HEVI-DUTY SLS-24-072T Power Supply - 24 V @ 7.2 A# Output 1, K Case

product

SOLA/HEVI-DUTY SLS-24-120T Power Supply - 24 V @ 12.0 A# Output 1, Case L

product

SOLA/HEVI-DUTY SLT-12-61818-12T Power Supply - 100 to 240 VAC; 5 V @ 6 A; 12 V @ 1.8 A/15 V @1.5 A...