VQ4 Series 3/11/99 5:06 PM Page 1
**
5 Port Solenoid Valve: Base Mounted
Metal Seal/Rubber Seal
Series VQ4000
SY
Space and capacity saving
SYJ
Pilot valve is gathered at one side.
SX
Space saving design which does not
VK
have any protrusions.
VZ
Space saving 40% less
Capacity saving 50% less VF
(In house comparison)
VFR
VP7
VP4
VQ
VQ4
Various centralized wiring options
Compact design with
High speed &
Large flow capacity
VQZ
Long life
kit kit
FT
(Suitable for cylinders up to ş140)
(D-sub connector) (Terminal box)
(Metal seal, with light and surge
VQD
suppressor)
VQ4100 17mS
VZS
(Single)
Built-in One-touch fitting
100 million cycles
VQ4200 12mS
∗ According to SMC life VFS
(Double)
for easier piping
test conditions
Enclosure:
Optional IP65 rating
Dispersion accuracy –3mS
VS
kit kit
LS
(Lead wire) (Serial transmission)
VS7
Optional IP65 is available.
Dust-tight, Jet-proof
Enclosure: Enclosure:
Optional IP65 rating Optional IP65 rating
Cylinder operation speed
Cylinder bore size mm
Valve width Cv Rubber seal Cylinder speed
mm (Metal seal) mm/s
40 50 63 80 100 125 140
Individual wiring style
150
300
kit
C
24.5 2.2
(Connector)
450
(2.0)
600
750
Pressure: 0.5MPa, Load rate: 50%
Note) Cylinder speed varies according to piping construction equipment.
So this Table is for your reference only.
Enclosure:
Performance value shown on catalog is typical value, this is not for
Optional IP65 rating
performance guarantee.
Grommet
1.11-1
COM
VQ4 Series 3/11/99 5:07 PM Page 2
**
Caution 1: Series VQ4000
Be sure to read before use. Refer to p. 0-33 to 0-36 for Safety Instruction and common precautions.
Warning Caution
Manual Override Connection of Lead Wire
When manual override is used, the connected equipment Plug-in sub-plate (With terminal block)
V
starts operating. Make sure that there is no danger. Non- Remove junction cover q of sub-plate where terminal block box
locking style (push style) is available as standard, locking w is mounted.
slotted style is optional style.
Non-locking push style
Bore ş5
Push down on the manual over-
ride button with a small screw-
driver until it stops.
w
Release the screwdriver and
q
the manual override will return.
Push down on the manual over-
Locking slotted style
ride button with a small screw-
driver until it stops.
Bore ş5
While down, turn clockwise by
90° to lock it. Turn it counter-
V
Markings shown below are on terminal block box, connect each
clockwise to release it.
power supply.
PUSH
Terminal block
A COM B
marking
T
Model
TURN
0
VQ410 A side COM
1
LOCK
0
VQ420 A side COM B side
1
Caution 3
4 0
VQ4 0 A side COM B side
5
1
Valve Mounting 6
After confirming the gasket is correctly placed under
Note 1) Not polar, possible to use as –COM.
0
the valve, tighten the mounting screws with the
Note 2) Double wiring is used on sub-plate VQ410 .
1
appropriate torque listed below.
Suitable tightening torque Nm
Plug lead: Grommet
0.8 to 1.2
Connect each corresponding wire.
Mounting screw (M3)
Lead wire color Lead wire color
SOL.A SOL.A
(–) Black (–) Black
COM COM
(+) Red (+) Red
SOL.B SOL.B
(–) White (–) White
Single solenoid Double solenoid
Caution
Single solenoid Double solenoid
Changing the One-touch Fittings
Black: A side solenoid (–) Black: A side solenoid (–)
The built-in fittings on the manifold can be changed easily.
Red: COM (+)
Simply remove the corresponding valve and take out the
Standard
fitting clip underneath. Then remove the affected fitting and
replace with a new one. Finally, replace the fitting clip and
White: B side solenoid (–)
Red: COM (+)
remount the valve.
Clip
Black: A side solenoid (–)
Red: COM (+)
Enclosure
(IP65)
White: B side solenoid (–)
(It is not used in case of single.)
One-touch ass'y
Green: (It is not used in case of either single or double.)
Note) No polarity. Possible to use as –COM.
1.11-2
VQ4 Series 3/11/99 5:08 PM Page 3
**
Base Mounted
Single Unit Series VQ4000
Caution
Installation/Removal of Light Cover Plug Lead
Removal of light cover
Installation/Removal Plug connector
V
Removal
with lead wires
V
Open the cover by inserting a small flat head screw driver into To install the connector simply insert
the slot on the side of the pilot assembly(see drawing below), it onto the pins, push the lever hook SY
lift the cover out about 1 mm and then pull off. (If the cover is into the groove and lock into place.
SYJ
V
pulled off at a angle, damage could be done to the O ring To remove the connector, push
and/or the pilot valve.) down on the lever and remove the
SX
V
Installation
hook from the groove.
Insert the cover straight onto the pilot assembly making sure Note) Do not use excessive force to
VK
Lever
not to contact the pilot valve and lock into place. remove the connector as this
Connector
might loosen the wire connections
VZ
O ring
inside the connector.
Light cover
VF
VFR
Caution
Internal Wiring Specifications
VP7
Caution
VP4
Changing the Pilot Valve
– (+)
SOL
V
Removal of Pilot Valve + (–)
Light ass'y
ZNR
1. Remove the light cover. (See
VQ
above) Then remove the
Light circuit ass'y
DC: Single
mounting screws that attach the (Orange)
VQ4
valve to the pilot assembly.
A side –(+) B side –(+)
2. Remove the light circuit board by VQZ
pulling it straight off the connector
SOL
VQD
pins. SOL
Mounting screw
B side
ZNR ZNR
V
Installing Pillot Valve A side
VZS
1. Insert the light circiut board onto
COM+(–)
A side light circuit B side light circuit
the connector pins on the pilot
ass'y (Orange) ass'y (Green)
DC: Double
VFS
valve.
Guide
2. Confirm that the gasket is on the
VS
pilot valve and tighten the
mounting screws with the torque
VS7
listed below.
Light circuit ass'y
SOL
(Orange)
Suitable tightening torque Nm
AC: Single
0.1 to 0.13
A side B side
Note) Pilot valves can be mounted on either direction.
Make sure that the light circuit board is mounted correctly
on the pilot valve. It is marked with an "A" or "B". (A side is
orange and B side is green.) If mounted on the wrong side,
the light will be darker.
COM
A side light circuit B side light circuit
SOL SOL
ass'y (Orange) ass'y (Green)
AC: Double
AB
Caution
Mounting indication
Enclosure IP65
Light circuit No.
SOL. A VQZ100-47-A
Wires, cables, connectors, etc. used for models conforming to IP65
SOL. B VQZ100-47-B
should also have enclosures equivalent to or stricter rating than IP65.
1.11-3
VQ4 Series 3/11/99 5:09 PM Page 4
**
Series VQ4000
Base Mounted Valve
Plug-in, Plug Lead/Single Unit
Model
(2)
Response time ms
(3)
(1)
Effective area Weight
Series Configuration Model
Standard: Low wattage
2
(mm ) (Cv) (kg)
1W and AC
0
Metal seal 36.0 (2.0) 20 or less 22 or less
VQ41 0
5 0.23
Single
0
(0.29)
Rubber seal 39.6 (2.2) 25 or less 27 or less
VQ41 1
5
0
Metal seal VQ42 0 36.0 (2.0) 12 or less 12 or less
5 0.26
Plug-in
Double
0
(0.32)
Rubber seal VQ42 1 39.6 (2.2) 15 or less 15 or less
5
0
Metal seal 32.4 (1.8) 45 or less 47 or less
VQ43 0
5 0.28
Closed
VQ4000
0
(0.34)
center
Rubber seal 36.0 (2.0) 50 or less 52 or less
VQ43 1
5
0
Metal seal VQ44 0 36.0 (2.0) 45 or less 47 or less
Exhaust 5 0.28
0
center (0.34)
Rubber seal VQ44 1 39.6 (2.2) 50 or less 52 or less
5
0
Metal seal 36.0 (2.0) 45 or less 47 or less
VQ45 0
Pressure 5
0.28
0
center
(0.34)
Rubber seal 39.6 (2.2) 50 or less 52 or less
VQ45 1
5
0
Metal seal VQ46 0 19.8 (1.1) 55 or less 57 or less
Double
5 0.50
check 0
(0.56)
Rubber seal VQ46 1 21.6 (1.2) 62 or less 64 or less
5
Plug lead Note 1) Value for valve on sub-plate and cylinder port Rc3/8
Note 2) As per JISB8375-1981 (Supply pressure: 0.5MPa, with indicator light and surge
suppressor, clean air).
Note 3) ( ): Weight of plug lead unit
Table: Without sub-plate
With sub-plate: Add 0.41kgf for plug-in style, 0.30kgf for plug lead style.
Standard Specifications
Seal Metal seal Rubber seal
Fluid Air, Inert gas Air, Inert gas
(3)
Symbol
Max. operating pressure 1.0MPa
Single 0.15MPa 0.20MPa
2 position single 3 position double check
Min. operating
(A) (B)
Double 0.15MPa 0.15MPa
(A)(B)
4 2
pressure
4 2
3 position 0.15MPa 0.20MPa
(1) (1)
5 1 3
–10 to 50˚C –5 to 50˚C
Ambient and fluid temperature
5 1 3 (R1) (R2) (P)
(R1)(P) (R2)
Lubrication Not required
2 position double (Metal)
Manual override Non-locking push style/Locking slotted style (Option)
(A) (B)
4 2
(2)
2
150/30 m/s
Shock/Vibration resistance
Dust proof (Available IP65 style)
Enclosure
5 1 3
Coil rated voltage 12, 24V DCand100, 110, 200, 220V AC (50/60Hz)
(R1)(P) (R2)
2 position double (Rubber)
Allowable voltage–10% of rated voltage
(A) (B)
4 2
Class B or equivalent
Coil insulation
(3)
24V DC 1W DC (42mA), 0.5W DC (21mA)
(3)
5 1 3
12V DC 1W DC (83mA), 0.5W DC (42mA)
(R1)(P) (R2)
Power cnsumption
100V AC Inrush 1.2VA (12mA), Holding 1.2VA (12mA)
3 position closed center
(A) (B) (Curent value)
Inrush 1.3VA (11.7mA), Holding 1.3VA (11.7mA)
110V AC
4 2
200V AC Inrush 2.4VA (12mA), Holding 2.4VA (12mA)
220V AC Inrush 2.6VA (11.7mA), Holding 2.6VA (11.7mA)
5 1 3
(R1)(P) (R2)
Note 1) Use dry air to prevent condensation when operating at low temperatures.
3 position exhaust center
Note 2) Shock resistance: No malfunction resulted from the impact test using a drop impact
(A) (B)
4 2
tester. The test was performed on the axis and right angle direction
of the main valve and armature, for both energized and de-energized
states. (Value in the initial stage.)
5 1 3
Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and
(R1)(P) (R2)
2,000 Hz. Test was performed at both energize and de-energized
3 position pressure center
states to the axis and right angle direction of the main valve and
(A)(B)
4 2
armature. (Value in the initial stage.)
Note 3) Values in case of low power consumption model (0.5W).
5 1 3
(R1)(P) (R2)
1.11-4
Solenoid specifications Valve specifications
3 position 2 position
VQ4 Series 3/11/99 5:09 PM Page 5
**
Base Mounted
Single Unit Series VQ4000
How to Order Valve
Body style
Port size
Without sub-plate
O: Plug-in
–
(for manifold)
Sub-plate
02 Rc1/4
03 Rc3/8
Piping
Side piping
–
Note) Refer to p.1.11-46
Bottom piping for thread standard.
B
SY
SYJ
Plug-in
VQ4 1 0 0
SX
Plug lead
VQ4 2 5 1
VK
Configuration Enclosure
VZ
– Dust-proof
2 position single 3 position closed center
(A) (B) (A) (B)
4 2 4 2 Dust tight, jet proof
VF
W
1 3
(Applicable to IP 65)
5 1 3 5 1 3
(R1) (R2) (P) (R1) (R2) (P)
VFR
2 position double 3 position exhaust center Manual override
(A) (B) (A) (B)
4 2 4 2
4 – : Non-locking push style B: Locking slotted style
VP7
5 1 3 5 1 3
(R1) (R2) (P) (R1) (R2) (P)
2
VP4
2 position double 3 position pressure center
(A) (B) (A) (B)
4 2 4 2
5
5 1 3 5 1 3
(R1) (R2) (P) (R1) (R2) (P)
VQ
3 position double check
(A) (B)
4 2
Note)
6
Light and surge voltage suppressor
VQ4
5 1 3
(R1) (R2) (P)
–
With
E W/o light/With surge suppressor
VQZ
Note) Refer to p.1.11-36
for double check
style.
Electrical entry
VQD
G
Body style
Coil voltage
VZS
Lead wire
1 100V AC (50/60Hz)
5: Plug lead
length 0.6m
Sub-plate 2 200V AC (50/60Hz)
VFS
3 110V AC (50/60Hz)
H
4 220V AC (50/60Hz)
VS
5 24V DC Lead wire
12V DC lenghth 1.5m
6
VS7
Function
– Standard (1W)
(1)
Low wattage (0.5W)
Y
Seal
(2)
External pilot
R
0 Metal seal
1 Rubber seal
Note 1) Applicable to DC
specification.
How to Order Sub-plate Note 2) Refer to p1.11-46 for
external pilot specification.
Combination of external
pilot and perfect interface is
VQ4000
not possible.
Note 3) When specifying more than
Electrical entry one option, indicate
Port size
symbols alphabetically.
P Plug-in conduit terminal
02
Rc1/4
Piping
S Plug lead
03
Rc3/8
–
Side piping
Note 1)Bottom piping type is
B
Bottom piping
Enclosure applicable to only Rc1/4. How to replace pilot valve ass'y (Voltage)
Note 2)Refer to p.1.11-46
V Refer to p.1.11-42 and p.1.11-43
– Dust proof
for thread standard.
for part no. of pilot valve ass'y
W Dust tight, Jet proof
V Refer to p.1.11-3 for “How to
Replace”.
1.11-5
Rubber Metal
Grommet
A
A
AB
A
AB
VQ4 Series 3/11/99 5:10 PM Page 6
***
Series VQ4000
Plug-in
Conduit terminal
0
2 position single: VQ410 –l
1
158
158
50
108
Indicator light
23.5 23.5
90 50
11 (A port)
11 (B port)
(12.5) (12.5)
42
13.5 13.5
14 5 1 3 12
2- ş5.6
30 45
Mounting hole
30 45
2- ş5.6
5-Rc1/4, 3/8
Manual override Mounting hole
(R1, R2=Rc1/4)
Bottom piping
SMC
PE X
R1 R2
P
G1/2 19.5 19.5
Rc1/8
(21) (21)
Electrical entry
Rc1/8 External pilot port
PE port 31 31
5-Rc1/4, 3/8
P, A, B, R1, R2 port
( ): Rc3/8
0 0
2 position double: VQ420 –l 3 position double check: VQ460 –l
1 1
0
3 position closed center: VQ430 –l
1
0
3 position exhaust center: VQ440 –l
181
1
0
108 73
3 position pressure center: VQ450 –l
1
90 50
11(A port) 11(B port)
(12.5) (12.5)
Indicator light
Indicator light
167 181
59 73
108
90 50
11 (A port) 11 (B port)
(12.5) (12.5)
14 5 1 3 12
30 45
Manual override
2- ş5.6
Mounting hole
14531 12
30 45
2- ş5.6
Mounting hole
Manual override
G1/2
Electrical entry
PE X
PE X
R1 R2
P
R1 R2
P
19.5 19.5 Rc1/8
Rc1/8
(21) (21)
External pilot port
Rc1/8 5-Rc (PT)1/4, 3/8
19.5 19.5
PE port
G1/2
31 31
PE port
P, A, B, R1, R2 port
5-Rc1/4, 3/8 (21) (21)
Electrical entry
P, A, B, R1, R2 port 31 31
: 3 position
( ): Rc3/8
1.11-6
15.5
15.5
B
14.5
27
24.6
30.5
38
32
48
41.5
79
14.5
24.6
27 38
48
30.5
32
41.5
79
(A, B port)
27
B
14.5
27
30.5
24.6
32
38
11 9
41.5
48
91.5
10.5
129
38
48
15.5
2 4
24
1
2 4
3 5
A
A
A
AB
AB
VQ4 Series 3/11/99 5:10 PM Page 7
***
Base Mounted
Single Unit Series VQ4000
Plug Lead
Grommet
0 G
2 position single: VQ415 –l
1 H
155.5
155.5
105.5 105.5
42.5 50 42.5 50
Indicator light
23.5 23.5
11 (A port)
11 (B port)
(12.5) (12.5)
SY
SYJ
42
14 5 1 3 12 SX
13.5 13.5
30 45
2- ş5.6
30 45
Manual override 2- ş5.6
Mounting hole VK
Mounting hole
5-Rc1/4, 3/8
(R1, R2=Rc1/4)
VZ
Bottom piping
VF
SMC
VFR
PE X
VP7
R1 R2
P
VP4
19.5 19.5 Rc1/8
Rc1/8
(21) (21)
External pilot port
PE port
5-Rc1/4, 3/8
31 31
P, A, B, R1, R2 port
VQ
( ): Rc3/8
VQ4
0 G 0
2 position double: VQ425 –l 3 position double check: VQ465
1 H 1
0 G
3 position closed center: VQ435 –l
1 H VQZ
0 G
3 position exhaust center: VQ445 –l
1 H
0 G
VQD
3 position pressure center: VQ455 –l
1 H
178.5
105.5 73
Indicator light
VZS
42.5 50
164.5 178.5
11(A port) 11(B port)
59 73
105.5 (12.5) (12.5)
VFS
Indicator light
42.5 50
11 (A port) 11 (B port)
VS
(12.5) (12.5)
VS7
14531 12
30 45
14513 12
Manual override 2- ş5.6
2- ş5.6
Mounting hole
30 45
Manual override
Mounting hole
PE X
PE X
R1 R2
P
R1 R2
P
19.5 19.5
Rc1/8
Rc1/8
19.5 19.5
Rc1/8 5-Rc (PT)1/4, 3/8
(21) (21)
PE port External pilot port
PE port (21) (21)
P, A, B, R1, R2 port
31 31
5-Rc (PT)1/4, 3/8 31 31
P, A, B, R1, R2 port
: 3 position
( ): Rc3/8
1.11-7
B
14.5
27 24.6
38
30.5
32 48
41.5
79 14.5 24.6
27
38
30.5 48
32
41.5
79
(A, B port)
27
B
14.5
27
30.5
24.6
32
38
11 9
41.5
48
10.5
91.5
129
38
48
2 4
24
1
2 4
3 5
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods