Elite.Parts Manufacturers S SMC PSE200
About product Datasheet FAQ

SMC PSE200

Description

SENSOR CONTROLLER 4CH 5OUT NPN

Part Number

PSE200

Price

Request Quote

Manufacturer

SMC

Lead Time

Request Quote

Category

PRODUCTS - P

Datasheet

pdf file

9644292_1.pdf

3341 KiB

Extracted Text

PSE Series 2/23/99 2:19 PM Page 7 ** Controller Series PSE100 How to Order PSE10 Option Output specifications — Without cover 0 NPN output C With cover 1 PNP output Mounting A Panel mounting ∗ B Wall mounting, DIN rail ∗Refer to p.3.1-14 for DIN rail part number. Controller Specifications Model PSE100-l PSE101-l Output specifications NPN Open Collector 30V 80mA max. PNP Open Collector 80mA max. Number of outputs 2CH X 2 outputs Pressure display range –101 to 10kPa (For vacuum), –10 to 100kPa (For low press.), –0.1 to 1MPa (For high press.) Display resolution 0.1kPa (For vacuum, low pressure), 1kPa (For high pressure) For vacuum pressure 2 kPa, mmHg, kgf/cm , bar, InHg and low pressure Display unit 2 For high pressure kPa, MPa, kgf/cm , bar Operating display Light at ON. (Switch output 1: Green, Switch output 2: Red) Frequency response 100Hz (10ms) Hysteresis Hysteresis mode: Variable, Window comparator mode: Fixed (2% F.S.) Temp characteristics–0.3% F.S. or less 25 – 10°C (25°C standard)–0.5% F.S. or less 0 to 50°C Repeatability–0.2% F.S. or less Supply voltage 12 to 24V DC (Ripple –10% or less) Current consumption 250mA or less Error display Error display at 7 segment LED Display specifications 4 figures X 2, 7 segment LED dispay, Sampling cycle 4 times/sec. Self diagnostic function Excess pressure, Excess current, NO sensor connection, Data error (Pressure presence at zero clear) Auto preset: Possible to set adsorption confirmation by pressing button only. Additional function Auto shift: Possible to zero clear by input terminal Operating temperature range 0 to 50°C (No condensation) Noise resistance 500Vp-p, Pulse width 1μs, Standing 1ns Voltage resistance Between external terminal and case 1000V AC, 50/60Hz for 1 min. Insulation resistance Between external terminal and case 2MΩ (500V DC by megameter) m 2 Vibration resistance 10 to 500Hz Width: 1.5mm or acceleration 98 /s (at the smaller vibration) to X, Y, Z direction (2 hours) m 2 Shock resistance 980 /s to X, Y, Z direction (3 times for each direction) Protective construction Panel mounting type: IP66 (Used gasket at panel mount part only), Wall mounting, DIN rail type: IP40 Mounting A: Panel mounting, B: Wall mounting, DIN rail Weight A: Approx. 90g B: Approx. 110 g Same as power supply Supply voltage Sensor 1 to 5V (Input impedance 100KΩ) Voltage input connection Current input 4 to 20mA (Input impedance 250Ω) 3.1-7 PSE Series 2/23/99 2:19 PM Page 8 * Controller PSE100 Input/Output Circuit and Connection Connection diagram Input/Output circuit diagram NPN output circuit diagram Pressure sensor 7 LED (Green) BROWN BLUE BLACK 8 OUT1 + 12 to 24V (BLACK) (RED) (WHITE) CH.SELECT – DC 9 LED (Red) OUT2 PSE 1 2 3 4 6 5 ZSE4 IN1 IN2 ISE4 1 to 5V 4 to 20mA PNP output circuit diagram ZSE5 ISE5 7 6 7 8 9 10 OUT1 ZSE6 8 LED (Green) + GND 12 to 24 V DC OUT1 OUT2 AUTO ISE6 12 to 24V – OUT2 DC SHIFT 9 (COM) LED (Red) ZSE3 ISE3 6 GS Input circuit diagram (Autoshift, channel selection) 7 PS 300 Sensor connection + ∗ 5 12 to 24V ISA CH.SELECT – DC 1.8kΩ Voltage input type Current input type ZSE1 6 ISE1 ∗Same as 10 AUTO SHIFT. ZSE2 ( ) GND(COM) GND COM 1 1 ISE2 How to use the auto shift function Connect the autoshift terminal 10 to GND . This 6 ZSP 12 to 24V DC 12 to 24V DC forces the unit to accept a new zero point, the display 2 2 will indicate "0". After disconnecting the autoshift terminal from GND, the display will indicate relative ISl pressure based on the new zero point. IN 1 to 5V IN 4 to 20mA 3 4 Note) To invoke the autoshift function the autoshift terminal has to be connected to GND for at least 10 ZSM msec. LED1 will display "0" during connection to GND. How to select channel PFl When CH.SELECT terminal is open, channel A 5 is selected. When it is connected to GND , channel 6 IFl B is selected. Note) There is a 10 msec. time delay from making contact and the actual selection of the channel. Description Display of peak, bottom and absolute pressure Display of present pressure (LED2) (LED1) PRESSURE SWITCH Display of channels Display of units kPa MPa mmHg 2 kgf/cm bar UP button ( ) Display of outputs InHg CH.A CH.B OUT1 OUT2 Increases calibration value. Light turns on when output is ON. Reset button (R) DOWN button ( ) Clears abnormality. Displays "0". Decreases calibration values. Auto preset button (A) Set button (S) Reads present pressure directly. Changes calibration value and modes. 3.1-8 Main Circuit Pressure sensor Main Circuit Pressure sensor Main Circuit Main Circuit Main Circuit Load Load Load Load     PSE Series 2/23/99 2:19 PM Page 9 ** PSE100 Calibration Procedure Procedure Manual calibration Calibrate set point for switch output. Initial setup Normal operation Select "Connect sensor", Measured pressure, "Display unit", "LED2 display displayed, switch mode" and "Output mode". operation occurs Auto Manual preset calibration Calibrate set point The data set by auto automatically for preset function can be adsorption confirmation. fine tuned. Method of calibration/1, 2, 3 Table 1 Table 2 Sensor types and min. display unit LED2 display Display unit LED2 (green) display indicates the following 3 mode options. 2 kPa MPa mmHg kgf/cm bar InHg Sensor type PSE511(–100kPa) –0.1 – –1 –0.001 –0.001 –0.1 Peak hold mode (L2_P) PSE512(100kPa) 0.1 – 1 0.001 0.001 0.1 Hold the display till next peak value. PSE510, 520(1MPa) 1 0.001 – 0.01 0.01 – Absolute pressure display mode (L2_A) Display based on atmospheric pressure. Bottom hold mode (L2_b) Hold the display till next bottom value. Table 3 Output type Time → One output type can be selected CH.A CH.B from 4 types according to output modes and relation of CH.A CH.B and can be selected by external signal. OUT1 OUT1 each calibration values. Two separate outputs, OUT1 and OUT2, can be set per OUT2 OUT2 channel and two channels, A Refer to p.3.1-8 "Channel selection" for further and B can be selected from information. outside. ON YES PHysteresis mode OFF P-2 P-1 Pressure/Vacuum Up→ P > = H (fixed hysteresis) =2% F.S. H H ON PWindow comparator mode NO OFF P-1 P-2 Pressure/Vacuum Up→ OUT1 Output mode ON ∗ OUT2: Same as OUT1. YES PHysteresis mode OFF n-2 n-1 Pressure/Vacuum Up→ > = n H (fixed hysteresis) =2% F.S. H H ON PWindow comparator mode NO OFF n-1 n-2 Pressure/Vacuum Up→ 3.1-9 Pressure/Vacuum UP→ PSE Series 2/23/99 2:19 PM Page 10 ** Controller PSE100 Initial setup 1. Initial setup mode 2. Selection of "Connect sensor" 3. Selection of "Display unit" PSE ZSE4 CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 "Display unit" is "LED Display mode" is ISE4 entered by pressing entered by pressing ZSE5 the button "S". the button "S". ISE5 Select "Connect sensor" by Press the button "S" at least 3 Select "Display unit" by pressing ZSE6 pressing the G button. seconds while holding down the the G or H button. (Refer to p.3.1-9 .) Table1 ISE6 LED2 display G button. ZSE3 : PSE511 (For –100kPa) ISE3 : PSE512 (For 100kPa) : PSE510/520 (For 1MPa) GS 4. Selection of "LED2 display mode" 5. Selection of "OUT1 output mode" 6. Selection of "OUT2 output mode" PS ISA ZSE1 CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 Press "Output mode" is By pressing the button "S", ISE1 entered by pressing the button "S". the calibration is completed. ZSE2 the button "S". ISE2 Select "LED2 display mode" by Select "OUT2 output mode" by Select "OUT1 output mode" by pressing the G button. pressing the G button. ZSP pressing the G button. LED2 display LED2 display : Absolute pressure LED2 display : Normal mode : Peak hold : Normal mode ISl : Reversed output mode : Bottom hold : Reversed output mode (Refer to p.3.1-9 .) Table 2 (Refer to p.3.1-9 .) Table 3 ZSM PFl IFl Manual calibration 1. Calibration value input mode (manual) 2. Input set point value for OUT1 (1) 3. Input set point value for OUT1 (2) CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 "OUT1(2) mode"is "Out2(3) mode" is enterd by pressing enterd by pressing the button "S" the button "S" Press the button "S" Gbutton: Increase set point value Gbutton: Increase set point value 3 seconds or less: Selected channel Hbutton: Decrease set point value Hbutton: Decrease set point value 3 seconds or more: Not selected channel R button: Reads the pressure value R button: Reads the pressure value at that moment at that moment (Refer to p.3.1-9 .) Table 3 4. Input set point value for OUT2 (3) 5. Input set point value for OUT2 (4) CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 "OUT2(4) mode" is By pressing the button "S" entered by pressing the calibration is completed. the button "S". Gbutton: Increase set point value Gbutton: Increase set point value Hbutton: Decrease set point value Hbutton: Decrease set point value R button: Reads the pressure value R button: Reads the pressure value at that moment at that moment 3.1-10 PSE Series 2/23/99 2:19 PM Page 11 * PSE100 Calibration Procedure Auto preset 1. Auto preset mode 2. Preparation for auto preset 3. OUT1 auto preset CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 After pressing button "S", OUT1 auto preset is completed. Press the button "A" for 3 to 6 When the initial conditions for Repeat the steps adsorption and When the button "A" is pressed, calibration is seconds for selected channel, and adsorption confirmation are met, no adsorption several times. for more than 6 seconds for not press the button "S". Press the H This will set the best values not completed. selected channel. button when it is not required to automatically. calibrate OUT1. ∗ Initial condition for adsorption confirmation means 4. Preparation for auto preset 5. OUT2 auto preset that conditions are met for operation to begin. CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 After pressing button "S", OUT2 auto preset is completed. When the button "A" is pressed, calibration is not When the initial condition for Repeat the steps adsorption and completed. adsorption confirmation are met, no adsorption several times. press the button "S". Press the H This will set the best values button when it is not required to automatically. calibrate OUT2. Other function Lock out Reset display to "0" Clear auto shift Lock out start Lock out release CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 CH.A CH.B OUT1 OUT2 Press the and buttons G Press the and buttons Press the button "R" for at least 3 Press the button "R" for at least 2 H G H simultaneously for at least 3 simultaneously for at least 3 seconds to reset the display to seconds but no longer than 3 seconds. Display starts to blink. seconds. Lock out is released. zero. If pressure is higher than – 2% seconds. This clears the auto shift During malfunction lockout is of rated pressure, reset of the function. released automatically. display is not possible. 3.1-11 PSE Series 2/23/99 2:19 PM Page 12 ** Controller PSE100 Error Codes Precautions Error codes Be sure to read before handling. Refer to p.0-26 and 0-27 for Display Cause Solution Safety Instructions and common precautions on the products mentioned in this catalog, and refer to p.3.0-7 to 3.0-9 for precautions on every series. Sensor is not connected. Connect sensor. PSE Wiring Operating pressure over Lower operating pressure. max. limit. ZSE4 Warning ISE4 qConnect FG to ground when using switching power supply as a power ZSE5 source. ISE5 Calibration data lost. Contact SMC. wEvery input signal needs to be longer than 10ms to be recognized by the ZSE6 PSE. ISE6 Installation ZSE3 Current draw on Output 1 Check load and/or wiring ISE3 too high (>120mA). for Output 1. Caution qFront plate of the PSE100 meets IP66 rating. However if the panel GS mount adaptor is used and the instrument is not seated correctly, water Current draw on Output 2 Check load and/or wiring might enter. PS too high (>120mA). for Output 2. wAs illustrated below, hook the nail located on the bottom of the body on the DIN rail and press down in the direction of the arrow. To remove ISA from the DIN rail lift the switch up with a bladed screw driver, etc. in the direction of the arrow. Current draw on Output 1 Check load and/or wiring ZSE1 eBe careful not to apply excessive force to the wiring during mounting on and 2 too high (>120mA). for Output 1 and 2. ISE1 panel or DIN rail. ZSE2 ISE2 Pressure is 2% above Panel mount Apply atmospheric rated pressure during pressure then do 0 clear. ZSP 0 clear. ISl 1 ZSM Turn screw 1/4 to 1/2 turn after panel makes contact with the PFl sealing surface of the PSE. IFl Mounting on DIN rail Removal from DIN rail 2a 2b Others Caution 1. Time delay for power on reset of controller is 0.5 seconds. Be aware that the output circuit is not active immediately after the power is connected. 3.1-12 PSE Series 2/23/99 2:19 PM Page 13 * PSE100 Dimensions A: Panel mount 56 l50 7.4 l48 Gasket (Accessory) PRESSURE SWITCH A Panel mount adaptor (Accessory) 55 11.4 Cover for display (Optional) 62 4 X 7.5 (= 30) 6.5 7.5 10-M3 2-M3 X 8L View A Cutout dimensions for panel mount 65 or more +0.6 45 0 N pieces: Side by side mounting (Ensure correct panel mount orientation) L +1 Side by side mounting: L= (48n-2.5) 0 ∗ Thickness of panel: 0.5 to 4 mm IP rating does not apply when units are mounted side by side. 3.1-13 30 8 10 +0.6 45 0 65 or more l 45 +0.6 45 0 PSE Series 2/23/99 2:19 PM Page 14 * Controller PSE100 B: Wall mount, DIN rail 4 X 7.5 (= 30) 4.8 6.5 7.5 Cover for display (Optional) PSE 2-ş4.4 10 mounting hole ZSE4 ISE4 1 2 3 4 5 ZSE5 ISE5 PRESSURE SWITCH ZSE6 ISE6 ZSE3 ISE3 GS PS ISA 6 7 8 9 10 ZSE1 ISE1 10-M3 17 11 ZSE2 6 23 ISE2 38 50 48 ZSP (54) ISl DIN rail ZSM L PFl 7.5 5 25 10 IFl Material: Aluminum Part number of DIN rail Part number L ISA-2-1 105 ISA-2-2 140 ISA-2-3 175 ISA-2-4 210 ISA-2-5 245 ISA-2-6 280 ISA-2-7 315 3.1-14 35 8 10 4.5 l48 56 4.5 (MAX.8) 70 l50 l45 12.5 35.5 27 High Precision, Remote Type Digital Pressure Sensor Series PSE530/200 ZSE� ISE� PSE Z SE3 I PS Z 1 SE I 2 ZSP ISA2 IS� ZSM PF2� IF� Data 1 MPa kPa A single controller monitors up to 2 OUT1 OUT2 CH 123 4 PRESSURE 4 pressure sensors. 4 SET 3 16-3-1 . . . . . . . . . . . . . . . 1 MPa A single controller monitors kPa 2 OUT1 OUT2 CH 123 4 PRESSURE 4 SET 3 Multi-channel Controller Pressure Sensor Series PSE200 Series PSE530 Space saving 1 �40 mm MPa kPa OUT1 OUT2 CH 123 4 PRESSURE SET 76% reduction in installation 165 mm space (Compared to the panel mounted ZSE40/ISE40.) kPa kPa kPa kPa OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 Less panel SET SET SET SET mounting work Panel mounting Simplified application 2 � The use of connector literally makes wiring work a snap. No tools required Thanks to a tool-free module press-in connector, all you need to do is to simply snap-in the lead wire and lock it! Crimping tools are not required. The connection cable is a halogen-free heavy-duty cord. (ISO 14000 compatible) Controller Pressure sensor Low power consumption: 55 mA or less (Controller) The new controller provides energy savings without compromising display brightness quality thanks to the use of transparent (negative) LCD and a backlight. 16-3-2 40 mm . Copy up to 4 pressure sensors. ZSE� ISE� PSE Z SE3 I Multifunction 3 PS � Display calibration (P. 16-3-17) � Auto shift function (P. 16-3-17) � Channel scan function (P. 16-3-18) Z 1 Each channel has an adjustable display Allows stable switch output even when supply Allows constant monitoring of the displayed SE I 2 function. pressure changes. pressure value for each channel. Although supply Displays exact the � Auto preset (P. 16-3-14) MPa kPa ZSP pressure for each same pressure Automatically sets the pressure value. channel is the same, values for all slightly different channels. CH values are displayed. � Auto identification function (P. 16-3-17) ISA2 MPa MPa MPa Can automatically identify the pressure range kPa kPa kPa MPa MPa kPa kPa OUT1 of a connected SMC sensor. OUT2 CH 123 4 IS� PRESSURE CH CH CH SET CH � Copy function (P. 16-3-17) MPa MPa kPa kPa Each channel’s information can be copied to ZSM another channel. CH CH MPa kPa CH1 setting can be copied to CH2, CH3, and CH4. MPa MPa kPa kPa PF2� CH CH2 CH CH • Reset function MPa MPa kPa kPa IF� CH1 CH3 • Key lock function CH CH • Displays peak & bottom pressure Data CH4 values � Anti-chattering function (P. 16-3-12) Prevents malfunction due to sudden pressure changes. Application 4 � Connectable to SMC’s other series � A single controller monitors various applications. (Series PSE510 & PSE52�) Ejector supply Suction Connecting to general purpose verification pressure verification pressure sensor PSE52� allows the sensor to verify hydraulic or liquid pressure rather than air pressure. PSE520 Verifies peening of a hydraulic cylinder. PSE520 Verifies supply pressure for MPa kPa line cleaning and washing operations. OUT1 OUT2 CH 123 4 PRESSURE SET PSE521 Placement Leak test Suctioning verification of wet work- pieces can be verified. Note) Connector types vary depending on the core wire size of the sensor cable and the outside diameter of insulation. Refer to “Connecting to other series” on page 16-3-21. 16-3-3 Copy Copy Pressure Sensor Series PSE530 How to Order PSE53 0 M5 Pressure sensing range High pressure [0 to 1 MPa] 0 Option 1 Vacuum [0 to –101 kPa] Nil Without cable 2 Low pressure [0 to 101 kPa] Sensor cable (3 m) 3 Compound pressure [–101 to 101 kPa] Port size L M5 M5 x 0.8 Option Sensor cable (3 m) + Connector (1 pc.) When only optional parts are required, order using the part Connector numbers listed below. CL Description Part no. Note Connector ZS-26-E 4 pcs. per set Sensor cable ZS-26-F Cable length: 3 m Note) At the factory, the connector is not connected to the Cable length: 3 m Connector + ZS-26-G The connector is not connected to cable, but packed together with it for shipment. Sensor cable the cable at the time of shipment. Specifications Model PSE530-M5 PSE531-M5 PSE532-M5 PSE533-M5 Rated pressure range 0 to 1 MPa 0 to –101 kPa 0 to 101 kPa –101 to 101 kPa Proof pressure 1.5 MPa 500kPa Air/Non-corrosive gas Fluid Power supply voltage 12 to 24 VDC (Ripple ±10% or less) Current consumption 15 mA or less Output specification Analog output (1 to 5 V, Output impedance: Approx. 1 kΩ) Accuracy ±2% F.S. or less (Within rated pressure range, Ambient temperature 25° ±3°C) Linearity ±1% F.S. or less Repeatability ±1% F.S. or less Power supply voltage effect ±1% F.S. or less based on the analog output at 18 V ranging from 12 to 24 VDC Enclosure IP40 Temperature range 0° to 50°C; Stored: –10° to 70°C (No freezing or condensation) Withstand voltage 1000 VAC, 50/60Hz for 1 minute between external terminals and case Insulation resistance 5 MΩ between external terminals and case (at 50 VDC) 2 Vibration resistance 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s acceleration, in X, Y, Z directions, for 2 hours each (De-energized) 2 Impact resistance 980 m/s in X, Y, Z directions, 3 times each (De-energized) Temperature characteristics (Based on 25°C) ±2% F.S. or less based on the analog output value at 25°C from a range of 0° to 50°C Port size M5 x 0.8 Material Body: Stainless steel Grade 303, Internal enclosure: PPE; Pressure sensor: Silicon; O-ring: NBR 2 Sensor cable/Option Halogen-free heavy-duty cord, ş2.7, 0.15 mm , 3 cores, 3 m 16-3-4 Resistance 4 3 2 1 � Pressure Sensor Series PSE530 Internal Circuit Brown Sensor cable color DC (+) Power supply Brown Black 12 to 24 VDC DC (–) GND Blue Load Blue Analog output (1 to 5 V) Black ZSE� ISE� PSE Dimensions Z SE3 I PSE53�-M5 PS 3.4 29.4 M5 x 0.8 Z 1 0.5 27.2 SE I 2 Pressure port ZSP ISA2 3 12 IS� 4 5 5.5 ZSM PF2� With sensor cable IF� Data 16-3-5 ş13 ş2.5 5.4 ş10.4 ş2.7 ş12 ş7.2 Main circuit Multi-channel Controller Series PSE200 How to Order PSE20 0 M Option 2 Input/Output specifications Nil Without connector 0 NPN 5 outputs + Auto shift input Sensor connector (4 pcs.) 1 PNP 5 outputs + Auto shift input 4C Unit specifications Nil With unit display switching function Note) M Fixed SI unit Connector Note) Fixed unit For vacuum low pressure & compound Option 1 pressure: kPa For high pressure: MPa Nil Without panel mount/protective cover Panel mount Accessory: Power supply/Output connection cable (2 m) Included with the controller. A Mounting screws (M3 x 8L) (Accessory) Waterproof seal Panel mount adapter Power supply/Output connection cable (Accessory) Panel ZS-26-A Front protective cover + Panel mount B Mounting screws (M3 x 8L) Front protective cover (Accessory) Waterproof seal Panel mount adapter (Accessory) Panel Option When only optional parts are required, order with the part numbers listed below. Description Part no. Note Panel mount adapter ZS-26-B Waterproof seal, screws included Front protective cover ZS-26-01 Front protective cover + ZS-26-C Waterproof seal, screws included Panel mount adapter ZS-26-D �48 conversion adapter �48 conversion adapter This adapter is used to mount Series PSE200 on the panel fitting of Series PS100. Order panel mount adapter separately. Connector ZS-26-E (4 pcs. per set) 16-3-6 Multi-channel Controller Series PSE200 Specifications Model PSE200 PSE201 Output specification NPN open collector PNP open collector Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With power supply polarity protection) 55 mA or less (Current consumption for sensor is not included.) Current consumption Power supply voltage for sensor [Power supply voltage] –1.5 V Note 1) Power supply current for sensor 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.) 1 to 5 VDC (Input impedance: Approx. 800 kΩ) Sensor input ZSE� No. of inputs 4 inputs ISE� Input protection With excess voltage protection (Up to 26.4 V) Variable Hysteresis mode Hysteresis PSE Window comparator mode 3-digit fixed No. of outputs 5 outputs (CH1: 2 outputs, CH2 to 4: 1 output) Z SE3 I 80 mA Maximum load current Switch output Maximum load voltage 30 VDC (With NPN) PS Residual voltage 1 V or less (With load current of 80 mA) With short circuit protection Output protection Z 1 SE I 2 Response time 5 ms or less Anti-chattering function With anti-chattering function, Response time selection: 20 ms, 160 ms, 640 ms ZSP ±0.1% F.S. or less Repeatability Setting/Display accuracy ±0.5% F.S. ±1 digit or less (at ambient temperature of 25° ±3°C) ISA2 For measured value display: 4-digit, 7-segment indicator, Display color: Yellow Display For channel display: 1-digit, 7-segment indicator, Display color: Red IS� Indication light Red (Lights up when output is ON.) Non-voltage input (Reed or Solid state), Input 10 ms or more, Independently controllable auto shift function ON/OFF Auto shift input ZSM Note 2) With auto identification function Auto identification function Enclosure Front face: IP65, Other: IP40 PF2� Ambient temperature range Operating: 0° to 50°C, Stored: –10° to 60°C (No freezing or condensation) Operating/Stored: 35 to 85% RH (No condensation) Resistance Ambient humidity range IF� 2 Vibration resistance 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s acceleration, in X, Y, Z directions for 2 hrs. each (De-energized) 2 Impact resistance 980 m/s in X, Y, Z directions, 3 times each (De-energized) Data Temperature characteristics ±0.5% F.S. or less based on 25°C Connection Power supply/Output connection: 8P connector, Sensor connection: 4P connector Enclosure: PBT; Display: Transparent nylon; Back rubber cover: CR Material Weight Approx. 60 g (Power supply/output connecting cable not included) Applicable pressure sensor PSE530 (For high pressure) PSE531 (For vacuum) PSE532 (For low pressure) PSE533 (For compound pressure) Regulating pressure range –0.1 to 1 MPa 10 to –101 kPa –10 to 101 kPa –101 to 101 kPa kPa — 0.1 0.1 0.1 MPa 0.001 — — — 2 kgf/cm 0.01 0.001 0.001 0.001 Note 3) Set pressure bar 0.01 0.001 0.001 0.001 resolution psi 0.1 0.01 0.01 0.02 mmHg — 1 — 1 InHg — 0.1 — 0.1 Note 1) If the Vcc and 0 V side of the sensor input connector are short circuited, the inside of the controller will be damaged. Note 2) Auto identification function comes with “Series PSE53�” pressure sensor only. Other SMC series (PSE510 and PSE520) are not equipped with this function. Note 3) For controllers with unit display switching function. (Either of SI units, [kPa] or [MPa], will be the set unit for those controllers without unit switching function.) 16-3-7 Series PSE200 Dimensions PSE200 & PSE201 �40 40.1 18.7 Connector 6 6.5 (option) MPa kPa OUT1 CH PSE200 OUT2 1 2 3 4 PRESSURE MADE IN JAPAN ZZ SET Sensor connector (4P x 4) Connector (Option) PIN no. Terminal DC (+) IN (1 to 5 V) DC (–) N.C. Power supply/Output connector (8P) Power supply/Output connection cable (Included) Pin no. PIN no. Terminal 8 Yellow : Auto shift input DC (+) 7 Green : CH4_OUT1 DC (–) 6 Red : CH3_OUT1 CH1_OUT1 5 Gray : CH2_OUT1 CH1_OUT2 4 White : CH1_OUT2 CH2_OUT1 3 Black : CH1_OUT1 2000 CH3_OUT1 2 Blue : DC (–) 1 Brown: DC (+) CH4_OUT1 Auto shift input 16-3-8 �36.8 4 3 2 1 � Multi-channel Controller Series PSE200 Dimensions Front protective cover + Panel mount 53 9.4 (2) 47 �42.4 ZSE� ISE� MPa kPa PSE OUT1 CH OUT2 Z 1234 SE3 I PRESSURE SET PS Z 1 SE I 2 Panel mount adapter Front protective cover ZSP Waterproof seal Panel �48 conversion adapter + Panel mount ISA2 6 2 �48 1.5 IS� ZSM MPa PF2� kPa IF� OUT1 CH OUT2 123 4 PRESSURE Data SET Panel mount adapter Waterproof seal Panel �48 conversion adapter 55 or more +0.1 �37.5 -0.2 Panel fitting dimension Applicable panel thickness: 0.5 to 8 mm 16-3-9 55 or more 46.4 Series PSE530/200 Descriptions 4-digit display Unit display Displays the measured The selected unit lights up. Use pressure value, content for unit labels for units other than MPa each setting, and error code. MPa and kPa. kPa Switch output display Unit labels Displays the output status of 2 OUT1 (CH1 to CH4), OUT2 kgf/cm bar PSI inHg mmHg OUT1 (CH1 only). OUT2 CH Lights up when it is ON. 123 4 Channel display UP button Displays the selected channel. PRESSURE Use this button to change the mode or set value. SET DOWN button SET button Use this button to change the Use this button to set the mode mode or set value. or set value. Internal Circuit and Connection Error Code & Solution PSE200-(M)� LED display Contents Solution • NPN open collector 5 outputs + Auto shift 1 input specification Excess current is Shut off the power flowing into the supply. After switch output of eliminating the DC (+) (Brown) DC (+) OUT1. output factor that Sensor input: +1 to 5 VDC caused the excess DC (–) Excess current is 1.2 k N.C. current, turn the flowing into the power supply back 7.3 k switch output of DC (+) Auto shift input (Yellow) on. OUT2. Sensor input: +1 to 5 VDC CH1_OUT1 (Black) DC (–) Pressure is applied N.C. +12 to 24 VDC to a pressure sensor CH1_OUT2 (White) + during the reset DC (+) CH2_OUT1 (Gray) operation (a zero Sensor input: +1 to 5 VDC – DC (–) point adjustment) as CH3_OUT1 (Orange) N.C. follows: Bring the pressure When compound CH4_OUT1 (Pink) back to atmospheric DC (+) pressure is used: pressure and use Sensor input: +1 to 5 VDC ± 2.5% F.S. or more. DC (–) the reset function DC (–) (Blue) N.C. When pressure other (zero point than compound adjustment) again. pressure is used: ±5% F.S. or more. ∗ After displaying for 2 seconds, it will return to the PSE201-(M)� measuring mode. • PNP open collector 5 outputs + Auto shift 1 input specification Supply pressure exceeds the DC (+) (Brown) maximum regulating Reduce/Increase DC (+) pressure. supply pressure to Sensor input: +1 to 5 VDC 1.2 k DC (–) within the regulating 7.3 k Auto shift input (Yellow) N.C. Supply pressure is pressure range. below the minimum DC (+) regulating pressure. Sensor input: +1 to 5 VDC CH1_OUT1 (Black) DC (–) N.C. CH1_OUT2 (White) +12 to 24 VDC + DC (+) CH2_OUT1 (Gray) Internal data error. Please contact SMC. Sensor input: +1 to 5 VDC – DC (–) CH3_OUT1 (Orange) N.C. CH4_OUT1 (Pink) DC (+) Internal data error. Sensor input: +1 to 5 VDC DC (–) DC (–) (Blue) N.C. Shut off the power supply and turn it back on. Please Internal data error. contact SMC if it does not recover. Internal data error. 16-3-10 Main circuit Main circuit Load Load Load Load Load Load Load Load Load Load Multi-channel Controller/Pressure Sensor Series PSE530/200 Operation 1: Initial Setting 1 Channel selection MPa kPa OUT1 OUT2 CH 123 4 CH1 CH2 CH3 CH4 PRESSURE ZSE� SET ISE� PSE SET button and hold for 2 seconds or longer. Press Z SE3 I 2 Range setting PS Z 1 MPa SE I 2 kPa OUT1 ZSP OUT2 CH 123 4 PRESSURE Compound pressure Vacuum Low pressure High pressure ISA2 SET IS� Note) Sensor range varies depending on the type of pressure sensor. Pressure Sensor/Sensor Range ZSM Sensor supply pressure (Compound pressure) (Vacuum) (Low pressure) (High pressure) Regulating pressure range –101 to 101 kPa 10 to –101 kPa –10 to 101 kPa –0.1 to 1 MPa PF2� Applicable pressure sensor PSE533 PSE531 PSE532 PSE530 IF� If the controller is equipped with a unit switching function, unit setting can be changed. SET (Refer to page 16-3-17 for details.) Data 3 Output mode setting OUT1 setting MPa kPa or OUT1 OUT2 CH 123 4 PRESSURE Normally Open Normally Closed SET SET (For CH2, CH3, and CH4, go to Response time setting.) OUT2 setting/(CH1 only) MPa kPa or OUT1 OUT2 CH 123 4 PRESSURE Normally Open Normally Closed SET SET 16-3-11 Series PSE530/200 Operation 1: Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 CH 123 4 PRESSURE 5 ms 20 ms 160 ms 640 ms SET Press SET button. Anti-chattering function Pressure ↑ Momentary change Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the supply pressure. This function prevents such momentary drops from being detected P1 Set value P2 as abnormal pressures by changing the response time setting. Time → t (ms) t (ms) The pressure values measured within the response time that is selected by the user are averaged. By comparing this average pressure value with the set pressure value, switch output (ON//OFF) is determined. Switch output ON operation OFF when normal Time → Switch output ON operation when anti-chattering OFF function is used. Time → 5 Manual setting/Auto preset MPa kPa or OUT1 OUT2 CH 123 4 PRESSURE Manual set mode Auto preset mode SET Press SET button. CH1 setting is completed when the channel display changes from blinking to lights on. Repeat the same setting steps for CH2 to CH4. 16-3-12 Multi-channel Controller/Pressure Sensor Series PSE530/200 Operation 2: Pressure Setting Manual setting Channel selection Output mode MPa kPa Hysteresis mode: Hysteresis of the switch output can be set arbitrarily. OUT1 OUT2 Hysteresis CH 123 4 ON PRESSURE Switch output 1 & 2 CH1 CH2 CH3 CH4 ZSE� SET OFF ISE� P2 P1 High pressure: Compound pressure type P4 P3 PSE Positive pressure type SET High vacuum: Vacuum type Z SE3 Manual mode OUT1 setting (1) I Hysteresis For normally open ON MPa kPa PS Displays Switch output 1 & 2 OFF alternately OUT1 Z 1 OUT2 CH SE 123 4 I 2 Increases the n2 n1 High pressure: Compound pressure type PRESSURE set value For normally closed n4 n3 Positive pressure type Decreases the SET ZSP High vacuum: Vacuum type set value Note) If the hysteresis is set for less than 2 digits, the switch output may ISA2 SET possibly chatter when the input pressure changes around the set value. OUT1 setting (2) Window comparator mode: Allows the switch output to be turned IS� Manual mode ON or OFF within any set pressure range. For normally open MPa kPa Displays ZSM Hysteresis Hysteresis alternately OUT1 OUT2 ON CH PF2� 123 4 Increases the Switch output 1 & 2 set value PRESSURE For normally closed OFF Decreases the SET set value IF� P1 P2 High pressure: Compound pressure type SET P3 P4 Positive pressure type High vacuum: Vacuum type Data SET (For CH1) Hysteresis Hysteresis OUT2 setting (1)/CH1 only Manual mode ON Switch output 1 & 2 For normally open MPa kPa Displays OFF alternately n1 n2 OUT1 High pressure: Compound pressure type OUT2 n3 n4 CH Increases the 123 4 Positive pressure type set value PRESSURE For normally closed High vacuum: Vacuum type Decreases the SET set value Note) The hysteresis is set to 3 digits. When setting the pressure, allow 7 digits or more. SET (For CH1) Note 1) Note 2) Window Regulating Main Hysteresis Display comparator OUT2 setting (2)/CH1 only pressure range application Manual mode mode mode MPa For normally open Adsorption and vacuum kPa –101.0 to 101.0 kPa P2(n2) ≤ P1(n1) P2(n1) > P1(n2) release verification Displays alternately 10.0 to –101.0 kPa Adsorption verification P2(n2) ≥ P1(n1) P2(n1) < P1(n2) OUT1 OUT2 CH 123 4 Supply pressure –10.0 to 101.0 kPa P2(n2) ≤ P1(n1) P2(n1) > P1(n2) Increases the PRESSURE verification set value For normally closed –0.1 to 1000.0 MPa P2(n2) ≤ P1(n1) P2(n1) > P1(n2) Leak test Decreases the SET set value ∗ P3(n3) and P4(n4) are the same as P1(n1) and P2(n2). Note 1) If the hysteresis is set too small, the switch output may possibly chatter when the input pressure changes around the set value. SET Note 2) The hysteresis is set to 3 digits. When setting the pressure in the window comparator mode, allow 7 digits or more. Manual mode If the allowance is less than 7 digits, the controller will not For CH1 operate. MPa kPa OUT1 Displays rectified value OUT2 CH 123 4 PRESSURE For CH2 to CH4 Displays zero when the auto shift input function SET is not turned on. SET To measuring mode 16-3-13 For CH2 to CH4 Measuring mode Series PSE530/200 Operation 2: Pressure Setting Auto preset Channel selection MPa kPa OUT1 OUT2 CH 123 4 PRESSURE CH1 CH2 CH3 CH4 SET Adsorption Verification SET High Suction Vacuum Auto preset mode Work 1 Work 2 Work n OUT1 auto preset preparation Max. A Prepare the equipment to be set in MPa kPa ON this mode. OUT1 OUT2 OFF CH 123 4 PRESSURE Min. B Released SET Work 1 Work 2 Work n Atmosphere Max. A: Maximum pressure value A – B ON = A – when workpiece is adsorbed. 4 A – B SET OFF = B + Min. B: Minimum pressure value 4 when workpiece is not adsorbed. OUT1 auto preset For adsorption verification: MPa kPa In this mode, repeat the adsorption and release of the workpiece for a OUT1 few times. OUT2 CH 123 4 The optimum values will be set PRESSURE automatically. SET For supply pressure verification: The optimum values will be set + automatically. In the case SET where OUT1 setting is not ( ) required. OUT2 auto preset preparation (CH1 only) For adsorption verification: MPa kPa Change the conditions of the workpiece such as the (suction) OUT1 nozzle with vacuum pad attachment OUT2 CH 123 4 and supply vacuum pressure. PRESSURE For supply pressure verification: SET Prepare the equipment for the OUT2 setting in this mode. SET OUT2 auto preset (CH1 only) MPa For adsorption verification: kPa In this mode, repeat the adsorption and release of the workpiece for a OUT1 few times. OUT2 CH 123 4 The optimum values will be set PRESSURE automatically. SET For supply pressure verification: The optimum values will be set + automatically. In the case SET where OUT2 setting is not ( ) required. To measuring mode 16-3-14 Measuring mode Multi-channel Controller/Pressure Sensor Series PSE530/200 Operation 3: Special Setting 1 Precision indicator setting Refer to A Display calibration function on page 16-3-17 for details. Calibration mode SET + MPa kPa Press and hold for 2 seconds or longer. OUT1 OUT2 CH 123 4 PRESSURE ZSE� SET ISE� PSE SET or Channel selection Z SE3 Calibration mode I After setting all 4 channels, press b SET utton. MPa kPa Proceed to the copy mode. PS OUT1 Z 1 OUT2 CH SE 123 4 I 2 PRESSURE Setting is complete (CH1). SET SET ZSP Return to calibration mode. Repeat the setting ISA2 SET procedure for CH2 to CH4. IS� Calibration mode Displays alternately SET Displays alternately MPa kPa ZSM OUT1 OUT2 Displays the supply pressure value CH PF2� 123 4 Displays the percentage. PRESSURE Displays the adjusted button increases the value. amount of pressure since SET IF� button decreases the value. the time of shipment (±5% R.D. or less). Data 2 Copy setting Refer to B Copy setting function on page 16-3-17 for details. Copy mode Copy mode Selection of the channel to be copied or MPa MPa kPa kPa OUT1 OUT1 OUT2 OUT2 CH CH 123 4 123 4 PRESSURE PRESSURE SET SET SET Selection of the channel Copy mode to be copied to MPa Displays kPa alternately OUT1 OUT2 SET CH 123 4 PRESSURE SET After setting for copy mode, ( ) press . SET SET Setting is complete. Proceed to the Return to the copy mode. auto shift mode. 16-3-15 Measuring mode Series PSE530/200 Operation 3: Special Setting 3 Auto shift Refer to C Auto shift function on page 16-3-17 for details. Auto shift mode or MPa MPa kPa kPa Displays alternately OUT1 OUT1 OUT2 OUT2 CH CH 123 4 123 4 PRESSURE PRESSURE On Off CH1 SET SET SET MPa kPa Displays alternately OUT1 OUT2 CH 123 4 PRESSURE On Off CH2 SET SET MPa kPa SET Displays alternately OUT1 OUT2 CH 123 4 PRESSURE On Off CH3 SET SET MPa kPa Displays alternately OUT1 OUT2 CH 123 4 PRESSURE On Off CH4 SET SET Setting is complete. Proceed to the auto identification mode. 4 Auto identification Refer to D Auto identification function on page 16-3-17 for details. Auto identification mode or MPa MPa kPa kPa OUT1 OUT1 OUT2 OUT2 CH CH 123 4 123 4 PRESSURE PRESSURE SET SET Auto identification mode Auto identification mode ON. OFF. SET Setting is complete. To measuring mode 16-3-16 Multi-channel Controller/Pressure Sensor Series PSE530/200 Function Details A B Display calibration function Copy function This function eliminates slight differences in the output values of all 4 Information that can be copied includes the following: q Pressure set channels and allows uniformity in the numbers displayed. Displayed values, w Range settings, e Display Units, r Output modes, t values of the pressure sensors can be adjusted to within ±5%. Response times. ±5% R.D. • When CH1 is copied to CH2, CH3, and CH4, information of OUT1 in CH1 will be copied. • When CH2, CH3, or CH4 is copied to CH1, information of OUT1 in CH2, CH3, or CH4 will be copied only to OUT1 in CH1. + ZSE� 0 Applied pressure ISE� Note) When the copy function is used, the regulating pressure value of the copied channel may change ±1 digit. PSE Displayed value at the time of shipment Z SE3 I Adjustable range of display calibration function Note) When the display calibration function is used, the regulating pressure PS value may change ±1 digit. Z 1 SE When auto shift is NOT used: I 2 C Auto shift function When the supply pressure fluctuates, a correct sensing is no longer possible. If there is a fluctuation in the supply pressure, erroneous operation may Supply pressure Supply pressure Supply pressure ZSP Pressure ↑ occur (e.g., in the case of adsorption verification, the switch does not turn normal drop increase ON even though the workpiece is being adsorbed, or does not turn OFF ISA2 even though the workpiece is no longer being adsorbed.) P1 Set value The auto shift function rectifies pressure changes to ensure proper P2 ON/OFF switch response during such fluctuations. IS� Time → ZSM At the point when the supply pressure fluctuates, the set pressure value is ON Switch output rectified by setting the auto shift input (external input) to Lo (no-voltage Does not turn OFF Does not turn ON 1 & 2 input), using the pressure measured at that point as a standard. OFF PF2� Time → • This function is good only for those channels whose function selection is turned “on” during the auto shift mode setting. When auto shift is used: IF� Set value Set value • Maintain the constant pressure for 10 ms or more after a drop in the auto rectification rectification shift input. Data Supply pressure Pressure ↑ Supply pressure Supply pressure • When the auto shift is input, “ooo” will be displayed for approximately 1 increase normal drop second, and the pressure value at that point will be saved as a rectified value “C_5” (for CH1) or “C_3” (for CH2 and CH3). Based on the saved P1 Set value rectified values, the set value “P_1” to “P_4” or “n_1” to “n_4” will likewise P2 be rectified. • The time from the moment the auto shift is input, to the moment the Time → switch output actually operates is 15 ms or less. • If the set value rectified by the auto shift input exceeds the regulating ON Switch output pressure range, it will be rectified once more to within the values of the 1 & 2 OFF regulating pressure range. Time → • When the auto shift function is turned “off”, the shift value will be zero. Switch output response time when 15 ms ( ) • When all of the auto shift functions are turned “off”, “ooo” will not be 10 ms or more auto shift is input. or less displayed even if the auto shift input is set to Lo (no-voltage input). Hi Auto shift • Values “C_5” and “C_3”, rectified after the auto shift is input, will be lost input Lo once the power is turned off. • Values “C_5” and “C_3”, rectified after the auto shift function is used, will be reset to zero (initial value) when the power is turned back on again. E Unit display switching function Note) Rectified values are not saved in EEPROM. Display units can be switched with this function. Units that can be displayed vary depending on the range of the pressure D Auto identification function sensors connected to the controller. Display units can be selected using either or . This function automatically identifies the pressure range of the pressure sensor that is connected to the multi-channel pressure sensor controller, Unit Display and Resolution thus eliminating the need of having to reset the range again after replacing the sensor. This function will be activated either when “Aon” is Applicable pressure sensor PSE530 PSE531 PSE532 PSE533 set in the auto identification mode or when the power is turned back on in Regulating pressure range –0.1 to 1 MPa 10 to –101 kPa –10 to 101 kPa –101 to 101 kPa that condition. However, this function only works in conjunction with kPa — 0.1 0.1 0.1 specific pressure sensors (SMC Series PSE53�). When other pressure 0.001 sensors are used, this function will not work. When using other types of MPa — — — pressure sensors, first set the auto identification mode to “AoF”, and then 2 kgf/cm 0.01 0.001 0.001 0.001 proceed to setting the range. Turning the power back on while in the “Aon” bar 0.01 0.001 0.001 0.001 setting can cause a malfunction. 0.1 0.01 psi 0.01 0.02 mmHg — 1 — 1 inHg — 0.1 — 0.1 16-3-17 Displayed pressure value Series PSE530/200 Operation 4: Other Functions Reset + Press and hold for 1 second or longer. Key lock Lock/Unlock selection SET SET Press and hold for 4 seconds or longer. Lock Unlock To measuring mode Note) Channel selection and channel scan operation will not be locked even if the key lock function is on. Peak/Bottom display Peak/Bottom selection Press and hold for 2 seconds or longer. Peak/Bottom mode OFF Peak mode Bottom mode SET SET SET Measuring mode Peak value blinks Bottom value blinks To return to the measuring mode, press any of these keys. SET ∗ If any buttons other than above are pressed during the peak/bottom mode, the peak/bottom mode will be deactivated. Channel scan Press and hold for Press and hold for 2 seconds or longer. 2 seconds or longer. CH1 CH2 Channel scan function deactivated. Return to the measuring mode. CH4 CH3 ∗ Pressure value for each channel are displayed at 2 second intervals. 16-3-18 Measuring mode Measuring mode Measuring mode Measuring mode Series PSE Specific Product Precautions 1 Be sure to read before handling. � � Controller Pressure Sensor Handling Handling Warning Warning 1. Do not drop, bump, or apply excessive impacts 1. Do not drop, bump, or apply excessive impacts (980 ZSE� 2 2 m/s ) while handling. Although the body of the (1000 m/s ) while handling. Although the body of ISE� the controller case may not be damaged, the inside sensor may not be damaged, the inside of the sensor could be damaged and lead to a of the controller could be damaged and cause a PSE malfunction. malfunction. Z 2. The tensile strength of the cord is 23 N. Applying a 2. The tensile strength of the power supply/output SE3 I greater pulling force on it can cause a malfunction. connection cable is 50 N; that of the pressure When handling, hold the body of the sensor—do sensor lead wire with connector is 25 N. Applying a PS not dangle it from the cord. greater pulling force than the applicable specified tensile strength to either of these components can 3. Do not exceed the screw-in torque of 3.5 N⋅m when Z 1 SE I 2 lead to a malfunction. When handling, hold the installing piping. Exceeding this value may cause body of the controller—do not dangle it from the malfunctioning of the sensor. ZSP cord. 4. Do not use pressure sensors with corrosive and/or inflammable gases or liquids. ISA2 Connection 5. Connecting the sensor cable (Option) Hold the female connector of the sensor cable with your Warning IS� fingers and carefully insert it into the connector. 1. Incorrect wiring can damage the switch and cause a malfunction or erroneous switch output. ZSM Connections should be done while the power is turned off. PF2� Sensor 2. Do not attempt to insert or pull the pressure sensor or its connector when the power is on. Switch IF� Male connector output may malfunction. Data 3. Wire separately from power lines and high voltage Female connector lines, avoiding wiring in the same conduit with these lines. Malfunctions may occur due to noise A connector cover is provided as part of the cable assembly from these other lines. (see the figure below). It is designed to keep the female connector from slipping out of the sensor. To lock the connector 4. If a commercial switching regulator is used, make cover in place, first make sure it is facing in the right direction sure that the F.G. terminal is grounded. as you slip it over the female connector, then lock it to the sensor body by turning it clockwise. To remove the cover, first unlock it by turning it counterclockwise, then pull back on it. To Operating Environment remove the female connector, grab it with your fingers and pull back on it. Do not pull on the cable. Warning 1. Our multi-channel pressure sensor controllers are CE marked; however, they are not equipped with Lock surge protection against lightning. Lightning surge Sensor countermeasures should be applied directly to system components as necessary. Connector cover 2. Our multi-channel pressure sensor controllers do not have an explosion proof rating. Never use Unlock pressure sensors in the presence of inflammable or explosive gases. 3. Enclosure “IP65” applies only to the front face of Operating Environment the panel when mounting. Do not use in an environment where oil splashing or spraying are Warning anticipated. 1. The pressure sensors are CE marked; however, they are not equipped with surge protection against lightning. Lightning surge countermeasures should be applied directly to system components as necessary. 2. The pressure sensors do not have an explosion proof rating. Never use pressure sensors in the presence of inflammable or explosive gases. 16-3-19 Series PSE Specific Product Precautions 2 Be sure to read before handling. Mounting Wiring Caution Caution 1. Connecting sensor cable and connector (ZS-26-E) The front face of the panel mount conforms to IP65 (IP40 when using the �48 conversion adapter); • Cut the sensor cable as shown below. however, there is a possibility of liquid filtration if the • Insert each lead wire into the corresponding connector number panel mount adapter is not installed securely and by following the chart provided below. properly. Securely fix the adaptor with screws as shown below. 20 mm or more Connector Core wire color no. of sensor cable Standard Brown (DC+) 1 Front protective cover Brown Black (Analog output) 1 2 (ZS-26-01) Panel mount Black 2 3 Blue (DC–) (ZS-26-B) Blue 3 N.C. 4 N.C. 4 • Make sure that the number of connector and the core wire color match. After verifying that the wires are inserted all the way, temporarily hold the connector down manually. • Using pliers, snap A into B as shown below so that there is no 2-M3 x 8L gap between A and B, and secure the connector. • The A and B portion of the sensor connector are already tacked Tighten screws 1/4 to 1/2 turn after the heads are flush with the panel. down temporarily at the time of shipment. Do not snap the A portion in place before inserting the cable. Note that the connector cannot be taken apart to be reused once it is crimped. Use a new sensor connector in case wiring or the When using �48 conversion adapter snapping of A into B are done incorrectly. �48 conversion adapter (ZS-26-D) B A Verify from the top side of A that the lead wires are inserted completely. • To connect the connector to the multi-channel pressure sensor, push the connector with its A portion facing toward you into the socket until it clicks as shown below. • To remove the connector, pull it straight out while applying pressure to the fingers on both sides. 1 2 3 4 Sensor connector port Power supply/Output connector 2. Connecting power supply/output connection cable • To connect the power supply/output connection cable to the controller, insert the cable connector with the C part facing down until it clicks. C 2 m 16-3-20 4 3 2 1 4 3 2 1 4 3 2 1 � Series PSE Specific Product Precautions 3 Be sure to read before handling. Wiring Caution 3. Connecting to other series ZSE� • Any pressure sensor (SW) can be connected as long as it ISE� generates analog output (1 to 5 V) signal. However, the pressure range must match. PSE • SMC pressure sensors, Series PSE510 & PSE520, are also connectable. Z SE3 I • When connecting to pressure sensors other than the Series PSE530, connector types will vary depending on the wire core PS size of the cable and the outside diameter of the insulation cover. Refer to the table provided below. Z 1 SE I 2 Insulation Connector Wire core size cover Sensor part no. part no. O.D. ZSP 2 ZS-26-E AWG24-26 (0.14 to 0.2 mm ) ş1.0 to 1.4 PSE510, PSE530 2 ZS-26-E-1 AWG24-26 (0.14 to 0.2 mm ) ş1.4 to 2.0 ISA2 2 ZS-26-E-2 AWG20-22 (0.3 to 0.5 mm ) ş1.0 to 1.4 PSE521 2 AWG20-22 (0.3 to 0.5 mm ) ZS-26-E-3 PSE520 ş1.4 to 2.0 IS� • Refer to the following diagram for connecting Series PSE520 to ZSM the connector. Brown 1 PF2� Black 2 Blue 3 N.C. 4 IF� F.G. Data Connect the shielding wire to the frame ground (F.G.) or F.G. terminal. There is no shielding wire for ( ) Series PSE510 & PSE530. Regulating Pressure Range & Rated Pressure Range Caution 1. Regulating pressure range: Refers to allowable pressure range in a pressure setting mode. • Setting range is between P_1(n_1) to P_4(n_4). • For Series PSE200, the regulating pressure range and the setting pressure range that can be displayed are the same. 2. Rated pressure range: Refers to the pressure range that satisfies the product specifications. • Pressure range that satisfies the product specifications (accuracy and linearity) for PSE530. 16-3-21 16-3-22 High Precision, Remote Type, 2-color Display Digital Pressure Sensor Series PSE540/560 ZSE� ISE� Compact Pressure PSE Sensor for Pneumatics Z Series PSE540 SE3 I PS � Weight g Z 1 SE I 2 � Dimension x x mm ZSP Pads can be directly mounted. Manifolding is ISA2 possible. IS� ZSM PF2� Pressure Sensor Controller IF� Series PSE300 9.6 18 Data � Response Time ms � Set Pressure Resolution Can be mounted in close proximity with each other either horizontally or vertically. PRESSURE MPa PRESSURE MPa PRESSURE MPa Pressure Sensor for OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 General Purpose Fluids SET SET SET Series PSE560 �30 � Connection � Wetted Material Power supply/Output connector Stainless steel 316L e-con connector • Copper-free • Oil-free (Single diaphragm) Sensor connector Washing line 2 outputs + Analog output or auto shift input 16-3-23 20.8 Variations Compact Pressure Sensor for Pneumatics P. 16-3-25 Series PSE540 Male thread type Plug-in reducer type M5 female thread, through type M3 x 0.5 R 1/8 (With M5 female thread) ş4 plug-in reducer M5 x 0.8 M5 x 0.8 (With mounting hole) M5 x 0.8 NPT 1/8 (With M5 female thread) ş6 plug-in reducer Pressure Sensor for General Purpose Fluid P. 16-3-27 Series PSE560 Male thread type Female thread type Applicable fluid example Argon Nitrogen Air containing drainage Hydraulic fluid Ammonia Silicon oil Freon Lubricating oil Carbon dioxide Fluorocarbon R 1/8, 1/4 (With M5 female thread) Rc 1/8 NPT 1/8, 1/4 (With M5 female thread) URJ 1/4, TSJ 1/4 Controller P. 16-3-36 Series PSE300 Functions • Auto shift function • Auto preset function • Precision indicator setting • Peak and bottom display function • Key lock function • Reset function • Error indication function • Unit display switching function • Anti-chattering function Rated pressure range Series PSE541 0 to –101 kPa Vacuum –101 kPa 0 For pneumatics PSE543 –100 to 100 kPa Compound pressure –100 kPa 100 kPa 0 to 1 MPa Positive pressure 01 MPa PSE560 0 to –101 kPa Low pressure PSE561 –101 kPa 0 For general purpose fluids PSE563 –100 to 100 kPa Compound pressure –100 kPa 100 kPa 0 to 500 kPa Positive pressure 0 500 kPa PSE564 16-3-24 ® Compact Pressure Sensor For General Air Series PSE540 ZSE� How to Order ISE� Pressure sensing range PSE 1 Vacuum (0 to –101 kPa) Option (Connector) 3 Compound pressure (–100 to 100 kPa) Z Nil C1 C2 SE3 I Connector for PSE200 multiple Connector for PSE300 multiple channel pressure controller channel pressure controller PS 1 pc. 1 pc. PSE54 1 M3 Without Z 1 SE I 2 Port size ZSP Note) At the factory, the connector is not connected to the cable, but M3 M3 x 0.5 packed together with it for shipment. M5 female thread, IM5 ISA2 through type M5 M5 x 0.8 M5 female thread, IS� 01 R 1/8 (With M5 female thread) Option/Part No. IM5H through type Description Part no. Note N01 NPT1 /8 (With M5 female thread) (With mounting hole) ZSM Connector for PSE200 ZS-26-E-4 1 pc. R04 ş4 plug-in reducer Connector for PSE300 ZS-28-C 1 pc. PF2� R06 ş6 plug-in reducer IF� Specifications Data Conforms to CE marking and UL (CSA) standards. Model PSE541 PSE543 Rated pressure range 0 to –101 kPa –100 to 100 kPa Proof pressure 500 kPa Fluid Air, No-corrosive gas, Non-flammable gas Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 15 mA or less Output specification Analog output 1 to 5 V (Within rated pressure range), Output impedance: Approx. 1 kΩ Accuracy (Ambient temperature of 25°C) ±2% F.S. or less Linearity ±0.4% F.S. or less Repeatability ±0.2% F.S. or less Power supply voltage effect ±0.8% F.S. or less Enclosure IP40 Operating temperature range Operating: 0 to 50°C, Stored: –20 to 70°C (No condensation or freezing) Operating humidity range Operating/Stored: 35 to 85% RH (No condensation) Withstand voltage 1000 VAC, 50/60 Hz for 1 minute between live parts and case Insulation resistance 50 MΩ between live parts and case (at 500 VDC) 2 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s acceleration, Vibration resistance in X, Y, Z directions, for 2 hours each (De-energized) 2 Impact resistance 980 m/s in X, Y, Z directions, 3 times each (de-energized) Temperature characteristics ±2% F.S. or less (based on 25°C) Piping Specifications Model M3 M5 01 N01 R04 R06 IM5 IM5H M5 female thread, R1/8 NPT1/8 ş4 ş6 M5 female thread, Port size M3 x 0.5 M5 x 0.8 through type M5 x 0.8 M5 x 0.8 plug-in reducer plug-in reducer through type (with mounting hole) Resin case: PBT Resin case: PBT Resin case: PBT Case PBT Material Fitting: Stainless steel 303 Fitting: C3604BD Fitting: A6063S-T5 Pressure sensing section Pressure sensor: Silicon, O-ring: NBR 2 Sensor cable 3-wire oval cable (0.15 mm ) With sensor cable 42.4 g 42.7 g 49.3 g 41.4 g 41.6 g 43.3 g 44.1 g Weight Without sensor cable 2.9 g 3.2 g 9.8 g 1.9 g 2.1 g 3.8 g 4.6 g 16-3-25 Resistance Series PSE540 Internal Circuit PSE54� Brown DC (+) Voltage output type 1 to 5 V 1 kΩ Black OUT Output impedance + 10 to 24 VDC Approx. 1 kΩ (Analog output) – Load Blue DC (–) Dimensions M3 R04 PSE54�- PSE5�- M5 R06 With across M3: M3 x 0.5 flats 7 M5: M5 x 0.8 A � � PSE54 -M3 PSE54 -M5 PSE54�-R04 PSE54�-R06 A 10.8 11.5 A ş4 ş6 B 3 3.5 B 18 20 Common dimensions PSE54�-IM5 18 3000 13 M5 x 0.8 01 PSE54�- PSE54�-IM5H N01 01: R 1/8 N01: NP T1/8 With across M5 x 0.8 7 flats 12 M5 x 0.8 16-3-26 ş3.4 10 A 9.6 10 14.4 B Main circuit 8.7 13 8.7 10 9 B 3 4 8 ® Pressure Sensor For General Fluids Series PSE560 ZSE� How to Order ISE� Pressure sensing range PSE 0 Positive pressure (0 to 1 MPa) Option (Connector) 1 Vacuum (0 to –101 kPa) Z SE3 Nil C1 C2 I 3 Compound pressure (–100 to 100 kPa) Connector for PSE200 multiple Connector for PSE300 multiple 4 Positive pressure (0 to 500 kPa) channel pressure controller channel pressure controller PS 1 pc. 1 pc. Without Z 1 SE I 2 PSE56 0 01 ZSP � Note 1) Current output type cannot be connected to PSE20 and Port size � PSE30 . R 1/8 (With M5 female thread) 01 ISA2 Note 2) The connector is not connected to the cable and is R 1/4 (With M5 female thread) 02 supplied loose at the time of shipment. Rc 1/8 C01 IS� Option/Part No. NPT 1/8 (With M5 female thread) N01 N02 NPT 1/4 (With M5 female thread) Output specifications Description Part no. Note ZSM A2 URJ 1/4 Nil Voltage output type 1 to 5 V Connector for PSE200 ZS-26-E-4 1 pc. B2 TSJ 1/4 28 Current output type 4 to 20 mA Connector for PSE300 ZS-28-C 1 pc. PF2� Specifications IF� Conforms to CE marking and UL (CSA) standards. Model PSE560 PSE561 PSE563 PSE564 Data Rated pressure range 0 to 1 MPa 0 to –101 kPa –100 to 100 kPa 0 to 500 kPa Proof pressure 1.5 MPa 500 kPa 500 kPa 750 kPa Model PSE56�-� PSE56�-�-28 Fluid Fluid, including gas, that will not corrode Stainlesss steel 316L Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 10 mA or less — Analog output 4 to 20 mA (Within rated pressure range) Analog output 1 to 5 V (Within rated pressure range) Output specification Allowable load impedance: 500 Ω or less (at 24 VDC) Output impedance: Approx. 1 kΩ 100 Ω or less (at 12 VDC) Accuracy (Ambient temperature of 25°C) ±1% F.S. or less Linearity ±0.5% F.S. or less Repeatability ±0.2% F.S. or less Power supply voltage effect ±0.3% F.S. or less Enclosure IP65 Operating temperature range Operating: –10 to 60°C, Stored: –20 to 70°C (No condensation or freezing) Operating humidity range Operating/Stored: 35 to 85% RH (No condensation) Withstand voltage 250 VAC for 1 minute between live parts and case Insulation resistance 50 MΩ between live parts and case (at 50 VDC) 2 10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s acceleration, Vibration resistance in X, Y, Z directions, for 2 hours each (De-energized) 2 Impact resistance 500 m/s in X, Y, Z directions, 3 times each (De-energized) Temperature characteristics ±2% F.S. or less (0 to 50°C, based on 25°C), ±3% F.S. or less (–10 to 60°C, based on 25°C) Piping Specifications Model 01 02 N01 N02 C01 A2 B2 R 1/8 R 1/4 NPT 1/8 NPT 1/4 Port size Rc 1/8 URJ 1/4 TSJ 1/4 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 Material Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316L 2 PSE56�-�: Oil proof 3-wire heavy-duty vinyl cable with air tube (0.2 mm ) Sensor cable 2 PSE56�-�-28: Oil proof 2-wire heavy-duty vinyl cable with air tube (0.2 mm ) With sensor cable 193 g 200 g 194 g 201 g 187 g 203 g 193 g Weight Without sensor cable 101 g 108 g 102 g 109 g 95 g 111 g 101 g 16-3-27 Resistance Series PSE560 Internal Circuit PSE56�-� PSE56�-�-28 Brown DC(+) Brown LINE(+) Load Voltage output type Current output type 1 to 5 V 4 to 20 mA 1 kΩ Black OUT + + 12 to 12 to Output impedance Allowable load impedance (Analog output) – 24 VDC – 24 VDC Approx. 1 kΩ 500 Ω or less (at 24 VDC) Load Blue DC(–) 100 Ω or less (at 12 VDC) Blue LINE(–) Load ∗ Install the load either on the LINE (+) or LINE (–) side. Dimensions 01 N01 PSE56�- / PSE56�- 02 N02 24 A 37.5 11.5 3025 5.5 30 B 5 20 Air tube M5 x 0.8 Part-C ∗ The dimensions of Part C are common to all PSE56� models. PSE56�-C01 24 B PSE56�-A2 Model AB A PSE56�-01 8.2 R 1/8 24 B PSE56�-02 12 R 1/4 PSE56�-N01 9.2 NPT 1/8 PSE56�-N02 12.2 NPT 1/4 PSE56�-C01 — Rc 1/8 PSE56�-A2 15.5 URJ 1/4 PSE56�-B2 9.5 TSJ 1/4 PSE56�-B2 A 24 B 16-3-28 Main circuit ş14 ş24 ş5.1 Main circuit 1 2 3 4 1 2 34 Series PSE Specific Product Precautions 1 Be sure to read before handling. � Pressure Sensor Handling Air Supply Warning Warning ZSE� ISE� 1. Do not drop, bump, or apply excessive impact 1. Use of toxic, corrosive or flammable gases 2 2 (PSE540: 980 m/s , PSE560: 500 m/s ) while han- Since the switch uses stainless steel 316L as the material of the PSE dling. Although the body of the sensor may not be pressure sensor and fittings, do not use toxic or corrosive damaged, the inside of the sensor could be damaged Z gases. SE3 and lead to malfunction. I 2. Fluid compatibility 2. The tensile strength of the cord is 50 N. Applying a PS greater pulling force to it can cause malfunction. Since the switch uses stainless steel 316L as the wetted When handling, hold the body of the sensor—do not material (for the pressure sensor and fittings), use fluids that will Z 1 SE dangle it from the cord. I 2 not corrode this material. 3. Do not use pressure sensors with corrosive and/or (For the corrosiveness of the fluids, please consult with the ZSP flammable gases or liquids. manufacturers of the respective fluids.) 20 mm or more Sheath 4. Connection of sensor connector ISA2 • Cut the sensor cable as illustrated to the right. Helium leakage test • Referring to the table below, insert each Helium leakage test is conducted on the welded parts. Use ferrules IS� lead wire of the cable at the position Insulator ® by Crawford Fittings (Swagelok fittings) as TSJ fittings, seals and marked with a number corresponding to the color of the lead wire. ® ZSM glands by Cajon (VCR fittings) as URJ fittings. If ferrules, seals, or Wire core color Connector glands of other brands are to be used, be sure to conduct helium no. For PSE200 (ZS-26-E) For PSE300 (ZS-28-C) PF2� leakage test before using those products. 1 Brown (DC (+)) Brown (DC (+)) 2 Black (OUT: 1 to 5 V) Not connected IF� 3 Blue (DC (-)) Blue (DC (-)) � 4 Controller Not connected Black (OUT: 1 to 5 V) Data • Confirm that the numbers on the Handling Part-A connector match the colors of the Warning wires and that the wires are inserted to the bottom. Press Part A by hand for 1. Do not drop, bump, or apply excessive impact 2 (100 m/s ) while handling. Although the body of the temporary fixing. controller case may not be damaged, the inside of • Press in the central part of Part A vertically with the controller could be damaged and cause a tool such as pliers. malfunction. • A sensor connector cannot 2. The tensile strength of the power supply/output be taken apart for reuse connection cable is 50 N; that of the pressure sensor once it is crimped. If the wire lead wire with connector is 25 N. Applying a greater arrangement is incorrect or pulling force than the applicable specified tensile if the wire insertion fails, use a new sensor connector. strength to either of these components can lead to • For connection to SMC Series PSE300 pressure switches, use malfunction. When handling, hold the body of the sensor connectors (ZS-28-C) or e-con connectors listed below. controller—do not dangle it from the cord. Manufacturer Part no. Sumitomo 3M 37104-3101-000FL Connection Tyco Electronics AMP 1-1473562-4 • For detailed information about e-con connectors, please Warning consult the manufacturers of the respective connectors. 1. Incorrect wiring can damage the switch and cause malfunction or erroneous switch output. Connections Operating Environment should be done while the power is turned off. 2. Do not attempt to insert or pull out the pressure Warning sensor or its connector when the power is on. Switch 1. The pressure sensors are CE marked; however, they output may malfunction. are not equipped with surge protection against 3. Wire separately from power lines and high voltage lightning. Lightning surge countermeasures should lines, avoiding wiring in the same conduit with these be applied directly to system components as lines. Malfunctions may occur due to noise from these necessary. other lines. 2. The pressure sensors do not have an explosion 4. If a commercial switching regulator is used, make proof rating. Never use pressure sensors in the sure that the F.G. terminal is grounded. presence of flammable or explosive gases. 16-3-29 Series PSE Specific Product Precautions 2 Be sure to read before handling. � Controller Operating Environment Mounting Warning Caution 1. Our pressure sensor controllers are CE marked; 3. Panel mount adapter removal however, they are not equipped with surge To remove the controller with panel mount adapter from the protection against lightning. Lightning surge equipment, remove the two mounting screws, and pull out the countermeasures should be applied directly to controller while pushing the claws outward. system components as necessary. Failure to follow this procedure can cause damage to the 2. Our pressure sensor controllers do not have an controller and panel mount adapter. explosion proof rating. Never use pressure sensors in the presence of flammable or explosive gases. Claw 3. Enclosure “IP65” applies only to the front face of the Claw panel when mounting. Do not use in an environment where oil splashing or spraying is anticipated. Mounting Caution 1. Mounting with bracket Mount the bracket on the body with two M3 x 5L mounting screws. Wiring Tighten the bracket mounting screws at a tightening torque of Caution 0.5 to 0.7 N·m. M3 x 5L 1. Connection and removal of sensor connector • Hold the lever and connector body with two fingers and insert Bracket the connector straight into the pin until it is locked with a click (Part no. ZS-28-B) sound. M3 x 5L • To remove the connector, pull it out straight while pressing the lever with one finger. 2. Mounting with panel mount adapter Secure the panel mount adapter with two M3 x 8L mounting Sensor connector screws. Panel Front protective cover M3 x 8L (Part no. ZS-27-01) Lever 2. Connector pin numbers for power supply/output cable DC (+) Brown 5 Panel mount adapter (Part no. ZS-27-C) OUT1 Black 4 Rotate 90° to mount. OUT2 White 3 Analog or auto shift Gray 2 DC (-) Blue 1 16-3-30 Series PSE Specific Product Precautions 3 Be sure to read before handling. Regulating Pressure Range and Rated Pressure Range Caution Set the pressure within the rated pressure range. ZSE� The regulating pressure range is the range of pressure that can be set on the controller. ISE� The rated pressure range is the range of pressure that satisfies the specifications (accuracy, linearity, etc.) of the sensor. Although it is possible to set a value outside the rated pressure range, the specifications will not be guaranteed even if the value stays PSE within the regulating pressure range. Z SE3 I Pressure range Sensor –100 kPa 0 100 kPa 500 kPa 1 MPa PS –101 kPa 0 kPa PSE541 Z 1 For vacuum SE I 2 PSE561 –101 kPa 10 kPa ZSP –100 kPa 100 kPa For compound PSE543 pressure PSE563 –101 kPa 101 kPa ISA2 0 1 MPa IS� PSE560 –100 kPa 1 MPa (–0.1 MPa) For positive ZSM pressure 0 500 kPa PSE564 PF2� –50 kPa 500 kPa IF� Rated pressure range of sensor Regulating pressure range of controller Data 16-3-31 16-3-32 Low Differential Pressure Sensor Series PSE550/300 ZSE� ISE� PSE Rated differential pressure range: Z SE3 I 0 to 2 0 to 2 kP kPa a 0 to 2 kPa PS Accuracy: Z 1 SE I 2 ZSP ± ±1 1% % F F.S. .S. ±1% F.S. ISA2 LED display to confirm energization IS� ZSM Proof pressure: 65 kPa PF2� Output: 1 to 5 VDC/ IF� (Analog output) 4 to 20 mADC Data Applications Applications Applications Filter clogging Liquid level Flow monitoring detection control Can control air flow by monitoring the flow rate Can control filtration and replacement periods Can detect the liquid level through changes in inside the duct. by monitoring the clogging of the filter. the purge pressure. Plug connection Plug connection T Tw wo mounting methods o mounting methods Controller Low differential PSE300 pressure sensor PSE550 e-con connector Direct mounting Bracket mounting 16-3-33 ® Low Differential Pressure Sensor Series PSE550 How to Order PSE550 Option 2 (Connector) Nil None Connector for PSE300 Output specifications multiple channel pressure controller 1 pc. Nil Voltage output type 1 to 5 V C2 28 Current output type 4 to 20 mA Note 1) Current output type cannot be connected to the Series PSE300. Note 2) The connector is unassembled in the factory but is included with the shipment. Option 1 (Bracket) Option/Part No. Nil None Bracket Description Part no. Note Bracket ZS-30-A With M3 x 5L (2 pcs.) Connector for PSE300 ZS-28-C 1 pc. A Note) The bracket is unassembled in the factory, but is included with the shipment. Specifications Model PSE550 PSE550-28 Rated differential pressure range 0 to 2 kPa Note) Operating pressure range –50 to 50 kPa Proof pressure 65 kPa Applicable fluid Air/Non-corrosive gas/Non-inflammable gas Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 15 mA or less — Analog output 4 to 20 mADC Analog output 1 to 5 VDC (Within rated differential pressure range) Output specification (Within rated differential pressure range) Allowable load impedance: Output impedance: Approx. 1 kΩ 500 Ω or less (at 24 VDC) 100 Ω or less (at 12 VDC) Accuracy (Ambient temperature of 25°C) ±1% F.S. or less Linearity ±0.5% F.S. or less Repeatability ±0.3% F.S. or less Indication light Orange light is on (When energized) Enclosure IP40 Operating temperature range Operating: 0 to 50°C, Stored: –20 to 70°C (No freezing or condensation) Operating/Stored: 35 to 85% RH (No condensation) Operating humidity range Withstand voltage 1000 VAC or more, 50/60 Hz for 1 minute between live parts and case Insulation resistance 50 MΩ or more between live parts and case (at 500 VDC) 2 10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 100 m/s acceleration, Vibration resistance in X, Y, Z directions, for 2 hours each (De-energized) 2 Impact resistance 300 m/s in X, Y, Z directions, 3 times each (De-energized) Temperature characteristics ±3% F.S. or less (Based on 25°C) ş4.8 (ş4.4 in the end) resin piping Port size (Applicable to I.D. ş4 air tubing) Material of wetted parts Resin pipe: Nylon, Piston area of sensor: Silicon 2 2 Sensor cable 3-wire oval cable (0.15 mm ) 2-wire oval cable (0.15 mm ) With sensor cable 75 g Weight Without sensor cable 35 g Note) Can detect differential pressure from 0 to 2 kPa within the range of –50 to 50 kPa. 16-3-34 Environmental resistance Low Differential Pressure Sensor Series PSE550 Analog Output 1 to 5 VDC 4 to 20 mADC 5 20 ZSE� ISE� 1 4 PSE 0 2 0 2 Differential Differential Z pressure [kPa] pressure [kPa] SE3 I Internal Circuit PS Z 1 PSE550 PSE550-28 SE Brown DC (+) Brown LINE (+) I 2 Load Voltage output type Current output type 1 to 5 V 4 to 20 mA 1 kΩ Black OUT ZSP + + 12 to 12 to Output impedance Allowable load impedance (Analog output) – 24 VDC – 24 VDC Approx. 1 kΩ 500 Ω or less (at 24 VDC) Load ISA2 Blue DC (–) 100 Ω or less (at 12 VDC) Blue LINE (–) Load IS� ∗ Install the load either on the LINE (+) or LINE (–) side. ZSM Dimensions PF2� 2 x ş3.5 through IF� Indicator light 27 24.3 37 Data ş15 11.7 10.4 2-M3 x 0.5 depth 4 With bracket A 37 27 7 20 A View ZS-30-A bracket 16-3-35 1.6 Analog output [V] Main circuit 10.7 7.3 38.5 25 68 25 ş4.8 ş4.4 Analog output [mA] 69.5 11.6 Main circuit 4.2 3000 9 37 40.9 ® Controller Series PSE300 How to Order Input/Output specifications Unit specifications 0 NPN2 output + 1-5 V output Nil With unit display switching function Note 1) 1 NPN2 output + 4-20 mA output M Fixed SI unit 2 NPN2 output + Auto shift input Note 1) Fixed unit 3 PNP2 output + 1-5 V output For vacuum & low pressure & low differential pressure & compound pressure: kPa 4 PNP2 output + 4-20 mA output Positive pressure: MPa (For 1 MPa) 5 PNP2 output + Auto shift input kPa (For 500 kPa) PSE30 0 M Option 1 Option 3 Nil Without cable Nil Without connector Power supply/Output connection cable Sensor connector Power supply/ Sensor connector Output connection cable L C (e-con connector) ZS-28-A ZS-28-C Note) The connector is unassembled in the factory, but is Note) The cable is unassembled in the factory, but is included with the shipment. included with the shipment. Option 2 Nil Without bracket/panel mount adapter/front protective cover Bracket M3 x 5L A Bracket M3 x 5L Panel mount adapter Panel B Mounting screw (M3 x 8L) (Accessory) Panel mount adapter Panel mount adapter + Front protective cover Option/Part No. Panel Front protective cover Description Part no. Note D Power supply/Output connection cable ZS-28-A Bracket ZS-28-B With M3 x 5L (2 pcs.) Mounting screw (M3 x 8L) Sensor connector ZS-28-C 1 pc. (Accessory) Panel mount adapter Panel mount adapter ZS-27-C With M3 x 8L (2 pcs.) Panel mount adapter + Front protective cover ZS-27-D With M3 x 8L (2 pcs.) Note) These options are unassembled in the factory, but are included with the shipment. 16-3-36 Controller Series PSE300 Specifications Conforms to CE marking and UL (CSA) standards. Model PSE30� Set (differential) pressure range –101 to 101 kPa 10 to –101 kPa –10 to 100 kPa –0.1 to 1 MPa –50 to 500 kPa –0.2 to 2 kPa Note 1) Pressure range For compound pressure For vacuum For low pressure For positive pressure For low difference pressure Rated (differential) pressure range –100 to 100 kPa 0 to –101 kPa 0 to 100 kPa 0 to 1 MPa 0 to 500 kPa 0 to 2 kPa Power supply voltage 12 to 24 VDC, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 50 mA or less (Current consumption for sensor is not included.) Sensor input 1 to 5 VDC (Input impedance: 1 MΩ) ZSE� ISE� No. of inputs 1 input Input protection With excess voltage protection (Up to 26.4 V) PSE Hysteresis Hysterisis mode: Variable, Window comparator mode: Variable Switch output NPN or PNP open collector output: 2 outputs Z SE3 I Maximum load current 80 mA Maximum load voltage 30 VDC (at NPN output) PS Residual voltage 1 V or less (With load current of 80 mA) Output protection With short circuit protection Z 1 SE I 2 Response time 1 ms or less Anti-chattering function Response time settings for anti-chattering function: 20 ms, 160 ms, 640 ms, 1280 ms ZSP Repeatability ±0.1% F.S. or less Output voltage: 1 to 5 V (Within rated pressure range (Differential pressure)), Output impedance: Approx. 1 kΩ Note 2) Voltage output ISA2 Linearity: ±0.2% F.S. (Not including sensor accuracy), Response speed: 150 ms or less Accuracy (To display value) (25°C) ±0.6% F.S. or less ±1.0% F.S. or less ±1.5% F.S. or less IS� Output current: 4 to 20 mA (Within rated pressure range) Note 2) Current output Maximum load impedance: 300 Ω (at 12 VDC), 600 Ω (at 24 VDC), Minimum load impedance: 50 Ω ZSM Linearity: ±0.2% F.S. (Not including sensor accuracy), Response time: 150 ms or less Accuracy (To display value) (25°C) ±1.0% F.S. or less ±1.5% F.S. or less ±2.0% F.S. or less PF2� ±0.5% F.S. Display accuracy ±0.5% F.S. ±1 digit or less (Ambient temperature of 25°C) ±2 digits or less IF� Display 3 + 1/2 digit, 7 segment indicator, 2-color display (Red/Green), Sampling frequency: 5 times/sec Indicator light OUT1: Lights up when ON (Green), OUT2: Lights up when ON (Red) Data Note 2) Auto shift input Non-voltage input (Reed or Solid state), Low level input: 5 ms or more, Low level: 0.4 V or less Enclosure IP40 Operating temperature range Operating: 0 to 50°C, Stored: –10 to 60°C (No freezing or condensation) Operating humidity range Operating/Stored: 35 to 85% RH (No condensation) Withstand voltage 1000 VAC for 1 minute between live parts and case Insulation resistance 50 MΩ or more between live parts and case (at 500 VDC Mega) 2 Vibration resistance 10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s acceleration, in X, Y, Z directions, for 2 hours each (De-energized) 2 Impact resistance 100 m/s in X, Y, Z directions, 3 times each (De-energized) Temperature characteristics ±0.5% F.S. or less (Based on 25°C) Connection Power supply/Output connection: 5P connector, Sensor connection: 4P connector Material Front case: PBT, Rear case: PBT With power supply/output connection cable 85 g Without power supply/output connection cable 30 g Note 1) Pressure range can be selected during initial setting. Note 2) Auto shift function is not available when analog output option is selected. Also, analog output option is not available when auto shift function is selected. Note 3) The following units can be selected with unit conversion function: 2 For vacuum & compound pressure: kPa·kgf/cm ·bar·psi·mmHg·inHg 2 For positive pressure & low pressure: MPa·kPa·kgf/cm ·bar·psi For low differential pressure: kPa·mmH2O Analog Output 1 to 5VDC 4 to 20 mADC Range Rated pressure range AB For vacuum 0 to –101 kPa 0 –101 kPa 5 20 For compound –100kPa to 100 kPa –100 kPa 100 kPa pressure 0 to 1 MPa 0 1 MPa For positive pressure 0 to 500 kPa 0 500 kPa Range Rated differential pressure range CD 1 4 For low differential 0 to 2 kPa 0 2 kPa pressure A B Pressure A B Pressure C D Differential pressure C D Differential pressure 16-3-37 Analog output [V] Weight Resistance Analog output Analog output [mA] Series PSE300 Internal Circuit PSE300 PSE303 NPN open collector output (2 outputs), Max. 30 V or 80 mA, residual voltage 1 V or less PNP open collector output (2 outputs), Max. 80 mA, residual voltage 1 V or less Analog output: 1 to 5 V Analog output: 1 to 5 V Output impedance: Approx. 1 kΩ Output impedance: Approx. 1 kΩ DC (+) DC (+) (Brown) (Brown) Analog output Analog output (Gray) (Gray) + + Load OUT1 OUT1 12 to 12 to 24 VDC 24 VDC (Black) (Black) – – OUT2 OUT2 (White) (White) Load Load DC (–) DC (–) (Blue) (Blue) PSE301 PSE304 NPN open collector output (2 outputs), Max. 30 V or 80 mA, residual voltage 1 V or less PNP open collector output (2 outputs), Max. 80 mA, residual voltage 1 V or less Analog output: 4 to 20 mA Analog output: 4 to 20 mA Maximum load impedance: 300 Ω (12 VDC), 600 Ω (24 VDC) Maximum load impedance: 300 Ω (12 VDC), 600 Ω (24 VDC) Minimum load impedance: 50 Ω Minimum load impedance: 50 Ω DC (+) DC (+) (Brown) (Brown) Analog output Analog output (Gray) + (Gray) + Load OUT1 12 to OUT1 12 to 24 VDC 24 VDC (Black) (Black) – – OUT2 OUT2 (White) (White) Load Load DC (–) DC (–) (Blue) (Blue) PSE302 PSE305 NPN open collector output with auto shift input (2 outputs), PNP open collector output with auto shift input (2 outputs), Max. 30 V, 80 mA, residual voltage 1 V or less Max. 80 mA, residual voltage 1 V or less DC (+) DC (+) (Brown) (Brown) + Auto shift input Auto shift input 12 to (Gray) (Gray) + 24 VDC – OUT1 OUT1 12 to 24 VDC (Black) (Black) – OUT2 OUT2 (White) (White) Load DC (–) DC (–) (Blue) (Blue) Descriptions Output (OUT2) display (Red) LCD Displays the current pressure, set mode, selected Lights up when OUT2 is ON. display unit, and error code. Four different display settings are available. Always use red or green display; or switch between green and red according to the output. SET button Use this button to change the mode or confirm the Output (OUT1) display (Green) set value. Lights up when OUT1 is ON. Up button Down button Use this button to select the mode or decrease the Use this button to select the mode or increase the ON/OFF set value. ON/OFF set value. It is also used for switching to the bottom display It is also used for switching to the peak display mode. mode. 16-3-38 Main circuit Main circuit Main circuit Load Load Load Load Load Load Main circuit Main circuit Main circuit Load Load Load Controller Series PSE300 Dimensions �30 31 3 20 ± 0.1 2–M3 x 0.5 Power supply/Output connector depth 4 ZSE� ISE� Sensor connector PSE 1.5 3.2 Z SE3 8.2 I PS Power supply/Output connection cable (ZS-28-A) Sensor connector Z 1 SE I 2 DC (+) Brown 5 PIN no. Terminal OUT1 Black 4 ZSP 1 DC (+) OUT2 White 3 2 N.C. Analog output or auto shift input Gray 2 ISA2 3 DC (–) DC (–) Blue 1 20 4 IN (1 to 5 V) 2 m 20 IS� With bracket ZSM A PF2� 30 20 IF� Data 7.2 22 35 41 ZS-28-B A View Bracket With panel mount adapter With panel mount adapter + Front protective cover 42.4 �34.5 7 24 �34.5 11 24 Panel thickness 0.5 to 6 ZS-27-D 8.75 Panel mount adapter + Front protective cover ZS-27-C Panel mount adapter 16-3-39 40 31.5 1.6 10 26.5 4.2 1.5 10 15 46 Series PSE300 Dimensions Panel cutout dimensions Horizontal stacking mount of multiple units (n pcs.) Mount of single unit 0 31 -0.4 31 x n pcs. + 3.5 x (n pcs. – 1) Vertical stacking mount of multiple units (n pcs.) 0 24 or more 31 –0.4 16-3-40 0 31 -0.4 0 31 24 or more -0.4 31 x n pcs. + 3.5 x (n pcs. – 1) Controller Series PSE300 Functions A D Auto shift function Peak and bottom display function This function constantly detects and updates the maximum and When there are large fluctuations in the supply pressure, the switch may fail to operate correctly. The auto shift function compensates minimum values and allows to hold the display value. such supply pressure fluctuations. It measures the (differential) E pressure at the time of auto shift signal input and uses it as the Key lock function reference (differential) pressure to correct the set value on the switch. This function prevents incorrect operations such as accidentally changing the set value. Set value correction by auto shift function Supply pressure Supply pressure Supply pressure F ZSE� Reset function normal drop increase ISE� This function clears and resets the zero value on the display of P 1 C 5 - - C 5 - H 1 measured (differential) pressure within ±7% F.S. of the factory (P 3) - - (H 2) - PSE adjusted value. Z G Error indication function SE3 I ON Switch output Error name Description Error code OFF 1·(2) PS OUT1 Switch output Overcurrent Load current of switch output 5 ms or more 10 ms or less response time Z 1 exceeds 80 mA. error SE I 2 when auto OUT2 shift is input. Hi ZSP Pressure applied during the zero Auto shift reset operation exceeds ±7% F.S. Lo input ∗ After displaying the error code for 3 Residual pressure ISA2 seconds, the switch automatically error Possible Set Range For Auto Shift Input returns to the measuring mode. Due to individual product differences, the Set (differential) pressure range Possible set range IS� setting range varies ±4 digits. –101.0 to 101.0 kPa –101.0 to 101.0 kPa Compound pressure Vacuum 10.0 to –101.0 kPa –101.0 to 101.0 kPa ZSM Supply pressure exceeds the maximum set (differential) pressure Low pressure –10 to 100.0 kPa –100.0 to 100.0 kPa or upper limit of the display pressure. –0.1 to 1.000 MPa –1.000 to 1.000 MPa PF2� Applied pressure Positive pressure –50 to 500 kPa –500 to 500 kPa A sensor may be unconnected or mis- error Low differential –0.2 to 2.00 kPa –2.00 to 2.00 kPa wired. Or, supply pressure is below the pressure IF� minimum set (differential) pressure or lower limit of the display pressure. B Auto preset function Data The value measured at the time of Auto preset function, when selected in the initial setting, calculates auto shift input is outside the set and stores the set value from the measured (differential) pressure. (differential) pressure range. Auto shift error The optimum set value is determined automatically by repeating ∗ After displaying the error code for one second, vacuum and break with the target workpiece several times. the switch returns to the measuring mode. Adsorption Verification Internal data error High Vacuum Absorption Work 1 Work 2 Work n Internal data error Max. A System error P 1 - Internal data error H 1 - Internal data error Min. B Non- absorption H Unit display switching function Work 1 Work 2 Work n Atmosphere Display units can be switched with this function. P 1 = A – (A – B) / 4 A = Maximum pressure value - Units that can be displayed vary depending on the range of the H 1 = (A – B) / 2 B = Minimum pressure value - pressure sensors connected to the controller. For For For low For For Pressure compound low differential C Display calibration function range vacuum positive pressure pressure pressure pressure This function eliminates slight differences in the output values and ∗∗ Applicable ∗ PSE533 PSE531 ∗ PSE530 allows uniformity in the numbers displayed. Displayed values of the PSE532 PSE564 PSE550 pressure PSE543 PSE541 PSE560 pressure sensors can be adjusted to within ±5%. sensor PSE563 PSE561 –101 to 101 10 to –101 –10 to 100 –0.1 to 1 –50 to 500 –0.2 to 2.00 Set (differential) ±5%R.D. pressure range kPa kPa kPa MPa kPa kPa kPa 0.2 0.1 0.1 — 1 0.01 MPa — — — 0.001 — — + 2 Applied pressure 0 kgf/cm 0.002 0.001 0.001 0.01 0.01 — 0.002 0.001 0.001 0.01 0.01 — bar Displayed value at the time of shipment psi 0.05 0.02 0.02 0.2 0.1 — Adjustable range of display calibration function 0.1 0.1 — — — — inHg Note) When the precision indicator setting function is used, the set 2 1 — — — 1 mmH2O mmHg (differential) pressure value may change ±1 digit. ∗ Series PSE530 pressure sensors are also applicable. Please contact SMC for more information. 16-3-41 (Differential) Pressure Display pressure value Series PSE300 Functions I Anti-chattering function A large bore cylinder or ejector consumes a large volume of air in operation and may experience a temporary drop in the supply pressure. This function prevents detection of such temporary drops in the supply pressure as an error. Response time settings: 20 ms, 160 ms, 640 ms, 1280 ms This function averages pressure values measured during the response time set by the user and then compares the average pressure value with the pressure set point value to output the result on the switch. Pressure Momentary change Pressure range P 1 - H 1 - Time t (ms) t (ms) Switch output ON operation in normal OFF conditions. Time Switch output ON operation when OFF anti-chattering function is on. Time 16-3-42 1 2 3 4 1 23 4 Series PSE Specific Product Precautions 1 Be sure to read before handling. � Pressure Sensor Handling Handling • Make sure that the air tubing is firmly inserted to avoid Warning possible disconnection. (Tensile strength is approx. 25 N 1. Do not drop, bump, or apply excessive impact while when being inserted 8 mm.) ZSE� handling. Although the body of the sensor may not ISE� • Please consult with SMC if you intend to use with fluids other be damaged, the inside of the sensor could be than air, non-corrosive gas and non-inflammable gas. damaged and lead to malfunction. PSE 2. The tensile strength of the cord is 50 N or less. Z Applying a greater pulling force to it can cause SE3 I Operating Environment malfunction. When handling, hold the body of the sensor—do not dangle it from the cord. PS Warning 3. Care should be taken when stripping the outer 1. The pressure sensors are CE marked; however, they cable covering as the insulator may be accidentally Z 1 SE are not equipped with surge protection against I 2 torn or damaged if incorrectly lightening. Lightning surge countermeasures stripped, as shown on the right. ZSP should be applied directly to system components 4. Do not use pressure sensors as necessary. with corrosive and/or flammable gases or liquids. ISA2 2. The pressure sensors do not have an explosion 5. Connection of sensor connector proof rating. Never use pressure sensors in the •Cut the sensor cable as 20 mm or more presence of flammable or explosive gases. Sheath IS� illustrated to the right. •Referring to the table ZSM Piping Connection below, insert each lead wire Insulator of the cable at the position Caution PF2� marked with a number • Cut the air tubing vertically. corresponding to the color Connector Wire core color • Carefully hold the air tubing IF� Air tubing no. of the lead wire. For PSE300 (ZS-28-C) and slowly push it into the • Confirm that the numbers 1 Data Brown (DC (+)) resin pipe, ensuring that it is 2 on the connector match the Not connected inserted by more than 8 mm. 3 colors of the wires and that Blue (DC (–)) For your information, the 4 Black (OUT: 1 to 5 V) the wires are inserted to tensile strength is approx. 25 Resin pipe the bottom. Press Part A by hand for N when inserted by more temporary fixing. than 8 mm. Part-A •Press in the central part of Part A • Insert the low pressure tubing into “Lo” pipe, and the high- vertically with a tool such as pliers. pressure tubing into “Hi” pipe. •A sensor connector cannot be taken apart for reuse once it is crimped. If the wire � Controller arrangement is incorrect or if the wire Handling insertion fails, use a new sensor connector. Warning •For connection to SMC 1. Do not drop, bump, or apply excessive impact 2 Series PSE300 pressure (100 m/s ) while handling. Although the body of the switches, use sensor controller case may not be damaged, the inside of the controller could be damaged and cause connectors (ZS-28-C) or e- malfunction. con connectors listed below. 2. The tensile strength of the power supply/output Manufacturer Part no. connection cable is 50 N; that of the pressure Sumitomo 3M 37104-3101-000FL sensor lead wire with connector is 25 N. Applying a Tyco Electronics AMP 1-1473562-4 greater pulling force than the applicable specified OMRON Corporation XN2A-1430 tensile strength to either of these components can lead to malfunction. When handling, hold the body •For detailed information about e-con connectors, please of the controller. consult the manufacturers of the respective connectors. • When piping, increase the length of the air tubing to allow for any possible warping, increased tension or moment load or increased tension, etc. • In cases where SMC air tubing is not used, make sure the product has similar I.D. accuracy within ş4 ± 0.3 mm. 16-3-43 Series PSE Specific Product Precautions 2 Be sure to read before handling. � Controller Connection Mounting 3. Panel mount adapter removal Warning To remove the controller with panel mount adapter from the 1. Incorrect wiring can damage the switch and cause equipment, remove the two mounting screws, and pull out the malfunction or erroneous switch output. controller while pushing the claws outward. Connections should be done while the power is Failure to follow this procedure can cause damage to the turned off. controller and panel mount adapter. 2. Do not attempt to insert or pull out the pressure sensor or its connector when the power is on. Switch output may malfunction. Claw 3. Wire separately from power lines and high voltage Claw lines, avoiding wiring in the same conduit with these lines. Malfunctions may occur due to noise from these other lines. 4. If a commercial switching regulator is used, make sure that the F.G. terminal is grounded. Operating Environment Warning Wiring 1. Our pressure sensor controllers are CE marked; Caution however, they are not equipped with surge protection against lightning. Lightning surge 1. Connection and removal of sensor connector • Hold the lever and connector body with two fingers and countermeasures should be applied directly to system components as necessary. insert the connector straight into the pin until it is locked with a click sound. 2. Our pressure sensor controllers do not have an •To remove the connector, pull it out straight while pressing explosion proof rating. Never use pressure sensors the lever with one finger. in the presence of flammable or explosive gases. Mounting Sensor connector Caution 1. Mounting with bracket Mount the bracket on the body with two M3 x 5L mounting screws. Lever Tighten the bracket mounting screws at a tightening torque of 0.5 to 0.7 N·m. 2. Connector pin numbers for power supply/output M3 x 5L DC (+) Brown 5 OUT1 Black 4 Bracket OUT2 White 3 (Part no. ZS-28-B) Analog or auto shift Gray 2 M3 x 5L DC (–) Blue 1 2. Mounting with panel mount adapter Secure the panel mount adapter with two M3 x 8L mounting screws. Panel Front protective cover M3 x 8L (Part no. ZS-27-01) Panel mount adapter (Part no. ZS-27-C) Rotate 90° to mount. 16-3-44 Series PSE Specific Product Precautions 3 Be sure to read before handling. Set Differential Pressure Range & Rated Differential Pressure Range Caution Set the pressure within the rated differential pressure range. ZSE� The set differential pressure range is the range of differential pressure that can be set on the controller. The rated differential pressure ISE� range is the range of differential pressure that satisfies the specifications (accuracy, linearity, etc.) of the sensor. Although it is possible to set a value outside the rated differential pressure range, the specifications will not be guaranteed even if the PSE valve stays within the set differential pressure range. Z Pressure range SE3 I Sensor –2 kPa 0 2 kPa 5 kPa 10 kPa PS For low 02 kPa differential PSE550 –0.2 kPa 2 kPa Z 1 pressure SE I 2 Rated differential pressure range of sensor ZSP Set differential pressure range of controller ISA2 IS� ZSM PF2� IF� Data 16-3-45 16-3-46 PSE Series 2/23/99 2:19 PM Page 3 *** Pressure Sensor For General Pneumatic Applications Series PSE 510 How to Order PSE51 Operating pressure Porting 0 High pressure (0 to 1 MPa) R06 ş6 reducer 1 Vacuum (–101 to 0 kPa) M5 X 0.8 M5 Low pressure (0 to 100 kPa) 2 01 R(PT) 1/8, M5 X 0.8 T01 NPTF 1/8, M5 X 0.8 Sensor Specifications/General Pneumatic Applications Model PSE510-l PSE511-l PSE512-l Operating pressure range 0 to 1 MPa –101 to 0kPa 0 to 100kPa 200kPa Max. pressure 1MPa Fluid Air, Non corrosive gases Output specification Analog (1 to 5V, Load impedance: 10kΩ or more) Supply voltage 12 to 24V DC (Ripple – 10% or less) Current consumption 10mA or less Operating temperature range 0 to 50°C (No condensation) Temperature– 1%F.S. or less 25 – 10°C characteristics – 1.5% F.S. or less (25°C standard) 0 to 50°C – 0.3% F.S. or less Repeatability Between external terminal and housing 1000V AC, 50/60Hz for 1 min. Voltage resistance Insulation resistance Between external terminal and housing 2MΩ (500V DC by megameter) m 2 Vibration resistance 10 to 500Hz Pulse width: 1.5mm or acceleration 98 / (at the smaller vibration) to X, Y, Z direction (2 hours) s m 2 Shock resistance 980 / to X, Y, Z direction (3 times for each direction) s Protective construction IP40 Note) When pressure sensor PSE510 series is connected to controller PSE100 series, display range is as series PSE100. Process Connection Model M5 01 T01 R06 Resin housing: PBT Resin housing: PBT Resin housing: PBT Fitting: Stainless steel Fitting: C3604BD Fitting: C3604BD Resin housing: PBT Housing Material (SUS303) (Electroless nickel plated) (Electroless nickel plated) Pressure sensor area Pressure sensor: Silicon, O ring: NBR 2 Lead wire Oil proof vinyl insulation ş2.55, 0.15mm X 3 wire (Brown, Blue, Black) 3000mm Port size ş6 reducer R(PT) 1/8, M5 X 0.8 NPTF1/8, M5 X 0.8 M5 X 0.8 Weight (Excluding lead wire) Approx. 7g Approx. 10g Approx. 12g 3.1-3 PSE Series 2/23/99 2:19 PM Page 4 ** Pressure Sensor PSE510 Internal Circuit Lead wire colors inside ( ) are those prior to conformity with IEC Caution standards. Power Be sure to read before handling. Refer to p.0-26 and 0-27 for Brown DC (+)············· voltage Safety Instructions and common precautions on the products (Red) + mentioned in this catalog, and refer to p.3.0-7 to 3.0-9 for Terminal precautions on every series. Analog Black OUT················· output (White) PSE ZSE4 ISE4 GND Blue DC (–)··············· terminal ZSE5 (Black) ISE5 ZSE6 ISE6 Dimensions ZSE3 ISE3 30 3000 GS 25.5 12 7 PS PSE510-01 RED(+) DC12 to 24V ISA WHITE(1) ANALOG1 to 5V BLACK(–) GND MAXPRESS 1MPa MADE IN JAPAN ZSE1 ISE1 ZSE2 ISE2 01, T01 ZSP ISl Width across flats 12 ZSM 01: R(PT) 1/8 PFl T01: NPTF 1/8 13 M5 X 0.8, depth 5 ∗ Reference dimensions after thread installation IFl M5 Width across flats 10 Gasket (Accessory) M5 X 0.8 13 R06 ş6 reducer Applicable fitting A H L T KQ 06-M5 16 S Y 13 Other series KQ, KS 13 KJ Series 14.5 KJ (-X20) Series 16 3.1-4 Main Circuit 22 24 30 A 19 ∗ (20) 10 10 13 10 ş7 PSE Series 2/23/99 2:19 PM Page 5 ** Pressure Sensor For General Purpose Fluid Applications Series PSE520 How to Order PSE52 0 Operating pressure Porting High pressure (0 to 1 MPa) 0 01 R(PT) 1/8, M5 X 0.8 02 R(PT) 1/4, M5 X 0.8 T01 NPTF 1/8, M5 X 0.8 T02 NPTF 1/4, M5 X 0.8 Sensor Specifications/General Purpose Fluid Applications Model PSE520-01 PSE520-02 PSE520-T01 PSE520-T02 0 to 1 MPa Operating pressure range Max. pressure 2MPa Fluid Fluid non corrosive to SUS304, SUS630 Output specification Analog (1 to 5V, Load impedance: 10kΩ or more) Supply voltage 12 to 24 V DC (Ripple – 10% or less) Current consumption 15mA or less Operating temperature range –10 to 70°C (No condensation or frost formation) Temperature 25 – 10°C– 1% F.S. or less characteristics (25°C standard) –10 to 70°C– 3% F.S. or less Repeatability– 0.3% F.S. or less Voltage resistance Between GND terminal and housing 250V AC for 1 min. Between external terminal and housing 100MΩ (50V DC by megameter) Insulation resistance 10 to 55Hz Pulse width: 1.5mm to X, Y, Z direction (2 hours) Vibration resistance m 2 294 / (11ms or less) to X, Y, Z direction (3 times for each direction) Shock resistance s Protective construction IP65 Housing Housing: Stainless steel (SUS304), Fitting: Stainless steel (SUS304) Material Pressure sensor area Diaphragm: Stainless steel (SUS630) 2 Lead wire Special elastic polyvinyl chloride ş6, 0.34mm , 3 wire, 3000mm Port size R(PT)1/8, M5 X 0.8 R(PT)1/4, M5 X 0.8 NPTF1/8, M5 X 0.8 NPTF1/4, M5 X 0.8 Weight Approx. 220g Note) When pressure sensor PSE 520 series is connected to controller PSE100 series, display range is as PSE100 series. 3.1-5 PSE Series 2/23/99 2:19 PM Page 6 ** Pressure Sensor PSE520 Internal Circuit Lead wire colors inside ( ) are those prior to conformity Power Caution with IEC standards. voltage Brown DC (+)············ Be sure to read before handling. Refer to p.0-26 and 0-27 for + Safety Instructions and common precautions on the products (Red) Terminal mentioned in this catalog, and refer to p.3.0-7 to 3.0-9 for precautions on every series. Analog Black OUT················ output (White) GND Blue DC (–)·············· PSE terminal (Black) ZSE4 ISE4 Shield wire ZSE5 ISE5 ZSE6 ISE6 ZSE3 ISE3 Dimensions GS PSE520-01, T01 PS 59.5 3000 ISA ∗ (55.5) 35 50 10 ZSE1 33.5 ISE1 M5 X 0.8 ZSE2 depth 5 ISE2 ZSP ISl 01: R(PT) 1/8 T01: NPTF 1/8 Protective tube Width across flats 19 ZSM (Resists bending) PFl PSE520-02, T02 IFl 61.5 3000 ∗ (55.5) 35 50 10 33.5 M5 X 0.8 depth 5 02: R(PT) 1/4 T02: NPTF 1/4 Protective tube Width across flats 19 (Resists bending) ∗ Reference dimensions after thread installation 3.1-6 Main Circuit ş32 ş32 Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of Note 1) "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 , Note 2) JIS B 8370 and other safety practices. Operator error could result in injury or equipment damage. Caution : Operator error could result in serious injury or loss of life. Warning : In extreme conditions, there is a possible result of serious injury or loss of life. Danger : Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems. Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. The expected performance and safety assurance will be the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2.Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed. 2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply pressure for this equipment and exhaust all residual compressed air in the system. 3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod, etc. 4. Contact SMC if the product is to be used in any of the following conditions: 1. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 16-14-3 Common Precautions Be sure to read before handling. For detailed precautions on every series, refer to main text. 4. Use clean air Selection If the compressed air supply is contaminated with chemicals, cynthetic materials, corrosive gas, etc., it may lead to break Warning down or malfunction. 1. Confirm the specifications. Products represented in this catalog are designed for use in Operating Environment compressed air appllications only (including vacuum), unless otherwise indicated. Warning Do not use the product outside their design parameters. Please contact SMC when using the products in applications 1. Do not use in environments where the product other than compressed air (including vacuum). is directly exposed to corrosive gases, chemicals, salt water, water or steam. Mounting 2. Do not expose the product to direct sunlight for an extended period of time. Warning 3.Do not use in a place subject to heavy 1. Instruction manual vibrations and/or shocks. Install the products and operate them only after reading the 4. Do not mount the product in locations where it instruction manual carefully and understanding its contents. is exposed to radiant heat. Also keep the manual where it can be referred to as necessary. Maintenance 2. Securing the space for maintenance When installing the products, please allow access for Warning maintenance. 1. Maintenance procedures are outlined in the 3. Tightening torque operation manual. When installing the products, please follow the listed torque specifications. Not following proper procedures could cause the product to malfunction and could lead to damage to the equipment or machine. Piping 2. Maintenance work If handled improperly, compressed air can be dangerous. Caution Assembly, handling and repair of pneumatic systems should 1. Before piping be performed by qualified personnel only. Make sure that all debris, cutting oil, dust, etc, are removed 3. Drain flushing from the piping. Remove drainage from air filters regularly. (Refer to the 2. Wrapping of pipe tape specifications.) When screwing piping or fittings into ports, ensure that chips 4. Shut-down before maintenance from the pipe threads or sealing material do not get inside the Before attempting any kind of maintenance make sure the piping. Also, when the pipe tape is used, leave 1.5 to 2 thread supply pressure is shut of and all residual air pressure is ridges exposed at the end of the threads. released from the system to be worked on. 5. Start-up after maintenance and inspection Air Supply Apply operating pressure and power to the equipment and check for proper operation and possible air leaks. If operation Warning is abnormal, please verify product set-up parameters. 1. Operating fluid 6. Do not make any modifications to be product. Please consult with SMC when using the product in Do not take the product apart. applications other than compressed air (including vacuum). Regarding products for general fluid, please ask SMC about applicable fluids. 2. Install an air dryer, aftercooler, etc. Excessive condensate in a compressed air system may cause valves and other pneumatic equipment to malfunction. Installation of an air dryer, after cooler etc. is recommended. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the bowl will over flow and allow the condensate to enter the compressed air lines. If the drain bowl is difficult to check and remove, it is recommended that a drain bowl with the auto-drain option be installed. For compressed air quality, refer to “Air Preparation Equipment” catalog. 16-14-4 Quality Assurance Information (ISO 9001, ISO 14001) Reliable quality of products in the global market To enable our customers throughout SMC’s quality control system the world to use our products with Make customers our even greater confidence, SMC has first priority, offering them reliable and Create new products using the friendly service. obtained certification for international latest technology, and offer the finest standards “ISO 9001” and “ISO Produce the highest products in a timely manner. quality with the participation of all 14001”, and created a complete employees. structure for quality assurance and environmental controls. SMC Quality policies products pursue to meet its customers’ expectations while also considering company’s contribution in society. Market research Product planning After service Sales coordination New product evaluation Quality system Research Education Reliability design education Design Reliability testing Training Training of Development Quality management system New technical suppliers Production development ISO 9001 Process control Inspection, testing, etc. Initial production control This is an international standard for quality control and quality assurance. SMC has obtained a large Quality control activities number of certifications in Japan and overseas, providing assurance to our customers throughout the world. Environmental management system ISO 14001 This is an international standard related to environmental management systems and environmental inspections. While promoting environmentally friendly automation technology, SMC is also making diligent efforts to preserve the environment. 16-14-5 SMC Product Conforming to Inter SMC products complying with EN/ISO, CSA/UL standards are supporting CE Mark The CE mark indicates that machines and components meet essential requirements of all the EC Directives applied. It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and components are exported to the member Nations of the EU. Once “A manufacturer himself” declares a product to be safe by means of CE marking (declaration of conformity by manufacturer), free distribution inside the member Nations of the EU is permissible. � CE Mark SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in accordance with CETOP (European hydraulics and pneumatics committee) guide lines. � As of February 1998, the following 18 countries will be obliged to conform to CE mark legislation Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, Greece, Liechtenstein, Sweden, Spain, Denmark, Germany, Norway, Finland, France, Belgium, Portugal, Luxembourg � EC Directives and Pneumatic Components • Machinery Directive The Machinery Directive contains essential health and safety requirements for machinery, as applied to industrial machines e.g. machine tools, injection molding machines and automatic machines. Pneumatic equipment is not specified in Machinery Directive. However, the use of SMC products that are certified as conforming to EN Standards, allows customers to simplify preparation work of the Technical Construction File required for a Declaration of Conformity. • Electromagnetic Compatibility (EMC) Directive The EMC Directive specifies electromagnetic compatibility. Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission). • Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. • Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L. Such vessels require EC type examination and then CE marking. 16-14-6 SMC Product Conforming to International Standards national Standards you to comply with EC directives and CSA/UL standards. Mark of compliance Mark of compliance for CSA/UL for CSA � CSA Standards & UL Standards UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric products, and are defined to mainly prevent danger from electric shock or fire, resulting from trouble with electric products. Both UL and CSA standards are acknowledged in North America as the first class certifying body. They have a long experience and ability for issuing product safety certificate. Products approved by CSA or UL standards are accepted in most states and governments beyond question. Since CSA is a test certifying body as the National Recognized Testing Laboratory (NRTL) within the jurisdiction of Occupational Safety and Health Administration (OSHA), SMC was tested for compliance with CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards. The above CSA NRTL/C logo is described on a product label in order to indicate that the product is approved by CSA and UL Standards. � TSSA (MCCR) Registration Products TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi (0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation. Products conforming to CE Standard With CE symbol for simple visual recognition In this catalog each accredited product series is indicated with a CE mark symbol. However, in some cases, every available models may not meet CE compliance. Please visit our web site for the latest selection of available models with CE mark. http://www.smcworld.com 16-14-7 SMC’s Global Service Network America Europe U.K. SMC Pneumatics (U.K.) Ltd. U.S.A. SMC Corporation of America Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN, Backinghamshire, U.K. 3011 North Franklin Road Indianapolis, IN 46226, U.S.A. TEL: 01908-563888 FAX: 01908-561185 TEL: 317-899-4440 FAX: 317-899-3102 GERMANY SMC Pneumatik GmbH CANADA SMC Pneumatics (Canada) Ltd. Boschring 13-15 D-63329 Egelsbach, Germany 6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada TEL: 06103-4020 FAX: 06103-402139 TEL: 905-812-0400 FAX: 905-812-8686 ITALY SMC Italia S.p.A. MEXICO SMC Corporation (Mexico), S.A. DE C.V. Via Garibaldi 62 I-20061 Carugate Milano, Italy Carr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo TEL: 02-9271365 FAX: 02-9271365 C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 CHILE SMC Pneumatics (Chile) S.A. Marne La Vallee Cedex 3 France Av. La Montaña 1,115 km. 16,5 P. Norte Parque TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvägen 29-31, S-141 05 Huddinge, Sweden ARGENTINA SMC Argentina S.A. TEL: 08-603-07-00 FAX: 08-603-07-10 Teodoro Garcia 3860 (1427) Buenos Aires, Argentina TEL: 011-4555-5762 FAX: 011-4555-5762 SWITZERLAND SMC Pneumatik AG Dorfstrasse 7, Postfach 117, CH-8484 Weisslingen, Switzerland BOLIVIA SMC Pneumatics Bolivia S.R.L. TEL: 052-396-3131 FAX: 052-396-3191 Avenida Beni Numero 4665 Santa Cruz de la Sierra-Casilla de Correo 2281, Bolivia AUSTRIA SMC Pneumatik GmbH (Austria) TEL: 591-3-3428383 FAX: 591-3-3449900 Girakstrasse 8, A-2100 Korneuburg, Austria TEL: 0-2262-6228-0 FAX: 0-2262-62285 VENEZUELA SMC Neumatica Venezuela S.A. Apartado 40152, Avenida Nueva Granada, Edificio Wanlac, SPAIN SMC España, S.A. Local 5, Caracas 1040-A, Venezuela Zuazobidea 14 Pol. Ind. Júndiz 01015 Vitoria, Spain TEL: 2-632-1310 FAX: 2-632-3871 TEL: 945-184-100 FAX: 945-184-510 PERU (Distributor) IMPECO Automatizacion Industrial S.A. IRELAND SMC Pneumatics (Ireland) Ltd. AV. Canevaro 752, Lince, Lima, Peru 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland TEL: 1-471-6002 FAX: 1-471-0935 TEL: 01-403-9000 FAX: 01-466-0385 URUGUAY (Distributor) BAKO S.A. NETHERLANDS (Associated company) SMC Pneumatics BV Galicia 1650 esq. Gaboto C.P. 11200, Montevideo, Uruguay De Ruyterkade 120, NL-1011 AB Amsterdam, Netherlands TEL: 2-401-6603 FAX: 2-409-4306 TEL: 020-5318888 FAX: 020-5318880 BRAZIL SMC Pneumaticos Do Brasil Ltda. GREECE (Distributor) S.Parianopoulos S.A. Rua. Dra. Maria Fidelis, nr. 130, Jardim Piraporinha-Diadema-S.P. 7, Konstantinoupoleos Street 11855 Athens, Greece CEP: 09950-350, Brasil TEL: 01-3426076 FAX: 01-3455578 TEL: 11-4051-1177 FAX: 11-4071-6636 DENMARK SMC Pneumatik A/S COLOMBIA (Distributor) Airmatic Ltda. Knudsminde 4 B DK-8300 Calle 18 69-05 Apart. Aereo 081045 Santa Fe de Bogotá, Colombia Odder, Denmark TEL: 1-424-9240 FAX: 1-424-9260 TEL: 70252900 FAX: 70252901 16-14-20 SMC’s Global Service Network Europe Oceania/Asia AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd. FINLAND SMC Pneumatics Finland OY 14-18 Hudson Avenue Castle Hill NSW 2154, Australia PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 02-9354-8222 FAX: 02-9894-5719 TEL: 09-8595-80 FAX: 09-8595-8595 NORWAY SMC Pneumatics Norway A/S NEW ZEALAND SMC Pneumatics (New Zealand) Ltd. Vollsveien 13C, Granfoss Năringspark N-1366 LYSAKER, Norway 8C Sylvia Park Road Mt.Wellington Auckland, New Zealand TEL: 67-12-90-20 FAX: 67-12-90-21 TEL: 09-573-7007 FAX: 09-573-7002 BELGIUM (Distributor) SMC Pneumatics N.V./S.A. TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. Nijverheidsstraat 20 B-2160 Wommelgem Belguim 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-355-1464 FAX: 03-355-1466 TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. HONG KONG SMC Pneumatics (Hong Kong) Ltd. ul. Konstruktorska 11A, PL-02-673 Warszawa, Poland 29/F, Clifford Centre, 778-784 Cheung, Sha Wan Road, Lai Chi Kok, Kowloon, TEL: 022-548-5085 FAX: 022-548-5087 Hong Kong TEL: 2744-0121 FAX: 2785-1314 TURKEY (Distributor) Entek Pnömatik San.ve Tic. Ltd. Sti Perpa Tic. Merkezi Kat:11 No.1625 80270 Okmeydani Istanbul, Türkiye SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. TEL: 0212-221-1512 FAX: 0212-221-1519 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 RUSSIA SMC Pneumatik LLC. 36/40 Sredny prospect V.O. St. Petersburg 199004, Russia PHILIPPINES SHOKETSU SMC Corporation TEL: 812-118-5445 FAX: 812-118-5449 Unit 201 Common Goal Tower, Madrigal Business Park, Ayala Alabang Muntinlupa, Philippines CZECH SMC Industrial Automation CZ s.r.o. TEL: 02-8090565 FAX: 02-8090586 Hudcova 78a, CZ-61200 Brno, Czech Republic TEL: 05-4121-8034 FAX: 05-4121-8034 MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. Lot 36 Jalan Delima1/1, Subang Hi-Tech Industrial Park, Batu 3 40000 Shah Alam HUNGARY SMC Hungary Ipari Automatizálási kft. Selangor, Malaysia Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 TEL: 03-56350590 FAX: 03-56350602 ROMANIA SMC Romania S.r.l. SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Str. Frunzei, Nr. 29, Sector 2, Bucharest, Romania Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, TEL: 01-3205111 FAX: 01-3261489 Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 SLOVAKIA SMC Priemyselná automatizáciá, s.r.o Nova 3, SK-83103 Bratislava CHINA SMC (China) Co., Ltd. TEL: 02-4445-6725 FAX: 02-4445-6028 7 Wan Yuan St. Beijing Economic & Technological Development Zone 100176, China TEL: 010-67882111 FAX: 010-67881837 SLOVENIA SMC Industrijska Avtomatilca d.o.o. THAILAND SMC Thailand Ltd. Grajski trg 15, SLO- 8360 Zuzemberk, Slovenia 134/6 Moo 5, Tiwanon Road, Bangkadi, Amphur Muang, Patumthani 12000, Thailand TEL: 07388-5240 FAX: 07388-5249 TEL: 02-963-7099 FAX: 02-501-2937 INDIA SMC Pneumatics (India) Pvt. Ltd. D-107 to 112, Phase-2, Extension, Noida, Dist. Gautaim Budh Nagar, U.P. 201 305, India TEL: (0120)-4568730 FAX: 0120-4568933 SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd. P.O.Box 240 Paardeneiland 7420 South Africa INDONESIA (Distributor) P.T. Riyadi Putera Makmur TEL: 021-511-7021 FAX: 021-511-4456 Jalan Hayam Wuruk Komplek Glodok Jaya No. 27-28 Jakarta 11180 Indonesia TEL: 021-625 5548 FAX: 021-625 5888 EGYPT (Distributor) Saadani Trading & Ind. Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt PAKISTAN (Distributor) Jubilee Corporation TEL: 3-548-50-34 FAX: 3-548-50-34 First Floor Mercantile Centre, Newton Road Near Boulton Market P.O. Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 16-14-21

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the PSE200 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

PNEUMATIC VLV

TWO HAND START MODULE

GASKET

LOCKING RING

PROTECTIVE TUBE

PROTECTIVE TUBE