Elite.Parts Manufacturers S SMC ISE30-T1-25
About product Datasheet FAQ

SMC ISE30-T1-25

Description

SENSOR PRESSURE 1MPA NPT/M5F NPN

Part Number

ISE30-T1-25

Price

Request Quote

Manufacturer

SMC

Lead Time

Request Quote

Category

PRODUCTS - I

Datasheet

pdf file

9644279_1.pdf

1712 KiB

Extracted Text

High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 ZSE� ISE� PSE Z SE3 I PS Z 1 SE I 2 ZSP ISA2 IS� ZSM PF2� IF� Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings are available. ∗ This photo shows 2 display colors simultaneously for product presentation purposes. In actual application, only one color is displayed at a time. Abnormal conditions can be detected at a glance! PRESSURE kPa PRESSURE kPa PRESSURE kPa PRESSURE kPa PRESSURE kPa OUT OUT OUT OUT OUT SET SET SET SET SET With One-touch fitting (ş4, ş6, ş5/32", ş1/4") Reduced dimensions in piping direction ∗ ∗ 17.8 mm reduction 12.4 mm reduction Straight type Elbow type 14.4 22.4 17.8 mm 12.4 mm 32.2 34.8 KQ2H06-M5 KQ2L06-M5 ∗ Comparison when One-touch fittings (KQ2H06-M5 / KQ2L06-M5) are connected to the piping ports (M5 x 0.8) 16-2-2 126 103.5 Each display required its own panel opening. Just one panel opening is required for stackable displays, which can be mounted either horizontally or vertically. Compact profile Space-saving improvement Economical use of space Old Model ZSE4E ISE4E Display calibration Old Model ZSE� ISE� PSE Z SE3 I PS New Model Z 1 SE I 2 New Model ZSP ZSE30 ISE30 ISA2 IS� This function allows uniformity in the numbers displayed. ZSM More user-friendly controls PF2� Raised rubber IF� button controls are Data clearly set apart, simple to operate, soft to the touch. Plug-type Applicable connectors take the panel thickness is burden out of up to 6 mm. wiring work and (Panel mounting) maintenance. High-precision With analog output resolution: 1/1000 In addition to the conventional voltage output type (1 to 5 V) Current output type (4 to 20 mA) is now available. • Convenient when longer wiring is required Variations • Excellent noise resistance Vacuum/Low pressure Positive pressure ZSE30 ISE30 Switches for vacuum and positive 100 kPa 1 MPa pressure can be easily distinguished. Rated pressure 0 0 The different display panel frame colors easily tell them apart. range –100 kPa Vacuum/Low pressure (ZSE30) Positive pressure (ISE30) Setting/Display resolution 0.2 kPa 0.001 MPa Switch output NPN/PNP open collector (1 output) Blue Gray Output Analog output Voltage output: 1 to 5 V; Current output: 4 to 20 mA 45 mA or less (70 mA or less for current output) Current consumption Panel mount/Bracket Option 16-2-3 �34.5 �40 ® High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2 m) L For positive pressure ISE30 01 25 M For vacuum/low pressure ZSE30 01 25 M Option 2 Piping specifications Nil None R 1/8 01 Bracket (With M5 female thread) NPT 1/8 A T1 (With M5 female thread) ş4 One-touch fitting Straight type C4H ş5/32" One-touch fiting Panel mount Output specifications 25 C6H ş6 One-touch fitting NPN output 65 PNP output B 26 1 to 5 V output N7H ş1/4" One-touch fitting 28 4 to 20 mA output ş4 One-touch fitting Elbow type C4L ş5/32" One-touch fitting Panel mount adapter + Front protective C6L ş6 One-touch fitting cover D ş1/4" One-touch fitting N7L Option Part No. Unit specifications When optional parts are required separately, use the following part numbers to place an order. Nil With unit switching function Note) M Fixed SI unit (International System of Units) Option Part no. Note Note) Fixed unit: Lead wire with connector ZS-27-A Lead wire length: 2 m For vacuum/Low pressure: kPA With mounting screws For positive pressure: MPa Bracket ZS-27-B (M3 x 5L: 2 pcs.) Panel mount adapter ZS-27-C With M3 x 8L (2 pcs.) Panel mount adater + Front protective cover ZS-27-D With M3 x 8L (2 pcs.) 16-2-4 High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 Specifications ZSE30 (Vacuum/Low pressure) ISE30 (Positive pressure) Rated pressure range –100.0 to 100.0 kPa 0.000 to 1.000 MPa Regulating pressure range –101.0 to 101.0 kPa –0.100 to 1.000 MPa Proof pressure 500 kPa 1.5 MPa Min. regulating unit 0.2 kPa 0.001 MPa Fluid Air, Inert gas, Non-flammable gas Power supply voltage 12 to 24 VDC, Ripple (p-p) 10% or less (With power supply polarity protection) ZSE� Current consumption 45 mA or less (at no load) ISE� Note 1) Switch output NPN or PNP open collector output: 1 output Max. load current 80 mA PSE Max. applied voltage 30 V (With NPN output) Z Residual voltage 1 V or less (With load current of 80 mA) SE3 I Response time 2.5 ms or less (Response time selections with anti-chattering function: 20, 160, 640, 1280 ms) Short circuit protection Yes PS Repeatability ±0.2% F.S. ±2 digit or less ±0.2% F.S. ±1 digit or less Note 2) Z 1 Output voltage: 1 to 5 V ±2.5% F.S. or less (With rated pressure range) SE Voltage output I 2 Linearity: ±1% F.S. or less, Output impedance: Approx. 1 kΩ Output current: 4 to 20 mA ±2.5% F.S. or less (With rated pressure range) Analog ZSP Linearity: ±1% F.S. or less output Note 3) Maximum load impedance: 300 Ω with power supply voltage of 12 V; Current output 600 Ω with power supply voltage of 24 V ISA2 Minimum load impedance: 50 Ω Hysteresis mode IS� Hysteresis Adjustable (can be set from 0) Window comparator mode 3 1/2 digit, 7-segment indicator, 2-color display (Red and green) ZSM Display Sampling cycle: 5 times/s ±2% F.S. ±2 digit ±2% F.S. ±1 digit PF2� Display accuracy (at 25°C ambient temperature) (at 25°C ambient temperature) Light up when output is ON (Green) Indicator light IF� Temperature characteristics ±2% F.S. or less (based on 25°C) Enclosure IP40 Data Operating temperature range Operating: 0 to 50°C, Stored: –10 to 60°C (No freezing or condensation) Operating humidity range Operating and stored: 35 to 85% RH (No condensation) Withstand voltage 1000 VAC for 1 min. between live parts and enclosure Insulation resistance 50 MΩ or more between live parts and enclosure (at 500 VDC) 2 Vibration resistance 10 to 150 Hz, 1.5 mm or 20 m/s amplitude in X, Y, Z directions for 2 hours each 2 Impact resistance 100 m/s in X, Y, Z directions 3 times each Compliant with CE Marking and UL (CSA) standards Standard Note 1) When switch output is selected, analog output is not available. Note 2) When voltage output is selected, a simultaneous selection of switch output and current output is not available. Note 3) When current output is selected, a simultaneous selection of switch output and voltage output is not available. Piping Specifications Part 01 T1 C4H C6H N7H C4L C6L N7L R 1/8 NPT 1/8 — — — — — — M5 x 0.8 M5 x 0.8 Port One-touch fitting ş4 mm — — ş6 mm ş1/4 inch — — — Straight type ş5/32 inch size One-touch fitting ş4 mm — — — — — ş6 mm ş1/4 inch Elbow type ş5/32 inch Sensor pressure receiving area: Silicon, Piping port: C3602 (Electroless nickel plated), O-ring: HNBR Wetted part material O-ring: NBR O-ring: NBR, fitting: PBT With lead wire 81 g 76 g 78 g with connector (2 m) Weight Without lead wire 43 g 38 g 40 g with connector 16-2-5 Environmental resistance Series ZSE30/ISE30 Setting Pressure setting Press the SET button. Press the SET button. Enter the set value of the Measuring mode pressure to perform switch Detects and displays the pressure and output. Measuring performs switch operations. Other functions such as the value clear function can be set mode Initial setting according to the application purpose. Set the output type, response Press the SET button time, and display color SET Press the button. and hold for 2 sec. or longer. switching. Initial Setting Initial setting mode 3. Output type setting Press and hold the SET button for 2 seconds or longer. The type of switch output can be set arbitrarily. Display monitor will be per Figure A below, and the switch While the current output type is displayed, press the will now be in the display color setting mode. �DOWN button to switch between normally open and normally closed . PRESSURE PRESSURE PRESSURE OUT Figure A OUT OUT If the unit specification indicated at the time of ordering is “M”, Normally open Normally closed the fixed SI unit will be used. If it is Nil, refer to “Unit Switching Press the SET button to set the output type and proceed to Function” on page 16-2-8. the response time setting. 1. Display color setting 4. Response time setting The switch output response time can be set arbitrarily. Select the color for LCD display. Chattering can be prevented with a response time setting. Press the �UP or �DOWN button to choose a display color. While the current response time is displayed, press the �UP PRESSURE PRESSURE or �DOWN button to select a new response time. PRESSURE PRESSURE PRESSURE OUT OUT ON: Red ON: Green OUT OUT OUT PRESSURE PRESSURE 2.5 ms 20 ms 160 ms PRESSURE PRESSURE OUT OUT ON/OFF: Red ON/OFF: Green Press the SET button to set the color and proceed to the OUT OUT operating mode setting. 640 ms 1280 ms If the analog output is set, press the �UP or �DOWN button and select the desired display color from (Green) or Press the SET button to set the response time and proceed (Red). Press the SET button to exit this mode and return to to the auto preset setting. the measuring mode. If the operating mode is the window comparator mode, press the SET button to return to the measuring mode. 2. Operating mode setting 5. Auto preset setting This mode will let you select the switch operating mode. While the current operating mode is displayed, press the This function stores the measuring pressure that is set �UP or �DOWN button to select a newly desired operating during the auto preset mode as a basic value. While the current setting is displayed, press the �UP or PRESSURE PRESSURE �DOWN button to select it as an auto preset setting. PRESSURE PRESSURE OUT OUT Hysteresis mode Window comparator mode OUT OUT Hysteresis Hysteresis Hysteresis Hysteresis Hysteresis Hysteresis (H) (H) (H) (H) (H) (H) Manual Auto ON ON ON ON OFF OFF OFF OFF Press the SET button to set the auto preset and return to the measuring mode. P1 n1 P1 P2 n1 n2 (Standard: Factory setting) (Reversed) (Standard: Factory setting) (Reversed) Press the SET button to set the mode and proceed to the output type setting. 16-2-6 High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 Pressure setting Auto preset setting Manual setting Press the SET button in the measuring mode to display the 1. Auto preset preparation mode set value. and the current set value blink alternately. While in the measuring mode, press the SET button to activate the auto preset preparation mode, and will be PRESSURE displayed. Proceed to prepare the devices to perform the pressure setting. While is still displayed, press both the ZSE� �UP and �DOWN buttons simultaneously to return to the ISE� PRESSURE Alternately measuring mode. OUT displayed PSE PRESSURE Normally Open Z SE3 PRESSURE I OUT OUT PS 2. Auto preset setting Z 1 OUT SE I 2 Press the SET button to activate the mode to execute auto Normally Closed preset functions. When is displayed, start the system ZSP operation and change the pressure. The set value will be Press the SET button to display the next set value. Press the automatically detected and stored. �UP or �DOWN button to change the value. (Refer to “How ISA2 While is still displayed, press the SET button to complete to Set Value” on the lower right hand corner of this page.) the setting and return to the normal measuring mode. IS� Hysteresis mode PRESSURE In this mode, hysteresis (H) and the set value for hysteresis ZSM are displayed alternately after setting P1. Press the SET button to return to the normal measuring mode. Press the OUT PF2� �UP or �DOWN button to change the value. (Refer to “How to Set Value” below right.) IF� How to Set Value Window comparator mode To enter a value such as the one for pressure setting: Data In this mode, P2 and the current set value are displayed 1. Press the �UP or �DOWN button to change the set alternately after setting P1. Press the SET button to display value. The first digit blinks. the next set value ( : hysteresis). Press the �UP or �DOWN button to change the value. (Refer to “How to Set Value” at right.) Next, and the set value for hysteresis will be displayed alternately. Press the SET button to return to the normal measuring mode. Press the �UP or �DOWN button to 1st digit change the value. 2. Press the �UP or �DOWN button to set the value (Refer to “How to Set Value” at right.) arbitrarily. (If there is no button operation for more than 10 seconds, the current value will be automatically set and the function will return to the set value display Pressure set value can be verified without holding or stopping mode.) the switch output operation. 3. With every push of the SET button, the next (higher) digit blinks. 2nd digit 3rd digit When the left-most digit is zero, “ ” or “ ” will blink. If the SET button is pressed while the left-most digit is blinking, the right-most digit will now blink. 4. Press and hold the SET button for 1 second or longer to return to the set value display mode. 16-2-7 Series ZSE30/ISE30 Setting Function setting Display calibration Key lock function During measuring mode, press the SET and �DOWN buttons This function prevents incorrect operations such as changing simultaneously and hold for 2 seconds or longer. and the set value accidentally. Press the SET button and hold for 4 current measured value will be displayed. seconds or longer to display the current or setting. Press the �UP or �DOWN button to change the set value. If Press the �UP or �DOWN button to select the setting and set there is no button operation for more than 2 seconds after this function with the SET button. Use the mode to avoid changing the set value, the display mode returns to displaying accidental button operation. To release a key lock function, and the current measured value. press the SET button and hold for 4 seconds or longer to display the current setting, and select the mode. PRESSURE PRESSURE Alternately Selection of lock and unlock displayed Press the SET button SET and hold for 4 sec. OUT OUT or longer Lock Unlock Current measured value Press the SET button to display the adjusted value (percent). The adjusted value and will be alternately displayed. PRESSURE PRESSURE Alternately displayed Zero out (Zero ADJ) function This function clears and resets the displayed value as long as OUT OUT the measuring pressure is within ±70 digits of the atmospheric Adjusted value pressure. (Percent) (Due to individual product differences, the setting range varies ±10% F.S.) Press the SET button to return to the normal measuring mode. This function is effective in detecting pressure fluctuations that exceed a certain amount without being affected by the supply PRESSURE pressure. Press and hold the �UP and �DOWN buttons simultaneously to reset the display. Release the buttons to return to the measuring mode. OUT + Press and hold for 1 second or longer. This function eliminates slight differences in the output values and allows uniformity in the numbers displayed. Displayed values of the pressure sensor can be calibrated to within ±5% for Series ISE and ±2.5% for Series ZSE. ±5% R.D. (±2.5% R.D.) Unit Conversion Function When not selecting “M” for unit specification + 0 Desired display unit can be selected. Applied pressure : Factory setting display value Press the �UP or �DOWN button to switch the unit, and set prior to shipment the set value is automatically converted. : Display calibration range The conversion order is: PA⇔GF⇔bAr⇔PSi⇔inH⇔mmH Note) When the display calibration function is used, the regulating pressure Press the SET button to set the unit and proceed to the value may change ±1 digit. display color setting. 2 For vacuum/low pressure Pa⇔kgf/cm ⇔bar⇔psi⇔inchHg⇔mmHg Peak/Bottom hold function 2 For positive pressure MPa⇔kgf/cm ⇔bar⇔psi This function constantly detects and updates the maximum Indication of Units and minimum pressure values and allows to hold the display value. Displayed unit ISE30 ZSE30 To use a peak hold function, press and hold the �UP button Pa 0.001 MPa 0.2 kPa for 1 second or longer. The maximum pressure value is held 2 kgf/cm 0.01 0.002 and blinks repeatedly. Press and hold the �UP button again bar 0.01 0.002 for 1 second or longer to release this function and return to psi 0.2 0.05 the measuring mode. mmHg — 2 To use a bottom hold function, press the �DOWN button for 1 inchHg — 0.2 second or longer. The minimum pressure value is held and blinks repeatedly. Press and hold �DOWN button again for 1 second or longer to release this function and return to the measuring mode. 16-2-8 Displayed pressure value Measuring mode Measuring mode Measuring mode High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 Description Indication light (Green) LCD display Displays the current pressure Displays the switch operation status. condition, setting mode conditions, selected display unit, MPa PRESSURE and error codes. A display color type can be selected from either a single color display with red or ZSE� green, or 2-color display in which ISE� �UP button green and red are switched according to the output. OUT Use this button to change the PSE mode or increase the ON/OFF set �DOWN button value. It also allows you to switch � SET Z Use this button to change the to the peak value display mode. SE3 I mode or decrease the ON/OFF set value. It also allows you to SET button switch to the bottom value display PS Use this button to switch the mode. mode and set the set value. Z 1 SE I 2 ZSP ISA2 IS� Error Correction Example of Internal Circuit and Wiring ZSM Take the following corrective solutions when errors occur. -25 NPN open collector output Error LCD Condition Solution Maximum 30 V, 80 mA PF2� description display Residual voltage: Brown DC(+) Shut off the power 1 V or less supply. After eliminating IF� over- Load the output factor that Load current of switch + current 12 caused the excess output is more than 80 mA. Black OUT error to Data current, turn the power – 24 VDC supply back on. Pressure is applied during the Blue DC(–) zero out operation as follows: When the switch for positive -26 pressure is used: ±0.071 MPa Analog output type or more. 1 to 5 V (±2.5% F.S.) Bring the pressure When the switch positive Residual back to atmospheric Output impedance: Brown DC(+) pressure is used: pressure pressure and try 1 kΩ ±7.1 kPa or more. error using the zero out After displaying for 3 seconds, Black OUT + function. 12 it will return to the measuring (Analog output) to mode. Due to the individual – product difference, the setting Load 24 VDC range varies ±10% F.S. Blue DC(–) Supply pressure exceeds -28 the maximum regulating Reduce/Increase Analog output type pressure. 4 to 20 mA (±2.5% F.S.) supply pressure to Applied within the regulating Maximum load impedance: Brown DC(+) pressure Supply pressure is below Power supply voltage 12 V: 300 Ω error pressure range. the minimum regulating Power supply voltage 24 V: 600 Ω Black OUT 12 pressure. + Minimum load impedance: 50 Ω (Analog output) to – 24 VDC Load Internal data error Blue DC(–) -65 Internal data error PNP open collector Shut off the power System Maximum 80 mA supply. Turn the error Brown DC(+) power supply back on. Internal data error If the power should + 12 not come back on, Black OUT to please contact SMC – 24 VDC for an inspection. Load Internal data error Blue DC(–) 16-2-9 Main circuit Main circuit Main circuit Main circuit � SMC Width across flats 12 Series ZSE30/ISE30 Dimensions 20 ±0.1 �30 25 8 9.5 2-M3 x 0.5 Lead wire with connector 3.6 Thread depth 4 M5 x 0.8 MPa PRESSURE OUT � SET 1.5 01: R 1/8 T1: NPT 1/8 A A (mm) Straight Elbow One-touch fitting size A B A B C ş4, ş5/32" 20 10.4 18 ş6 14.4 11.2 22.4 12.8 20 ş1/4" 22.8 13.2 20.5 şB Straight Elbow With One-touch fitting With bracket 3 22 30 20 25 35 35 16-2-10 45 4.2 1.8 20 şB 10 10 15 42.5 30 SMC C 20 ±0.1 � R4.5 High Precision, 2-color Display Digital Pressure Switch Series ZSE30/ISE30 Dimensions Panel mount ZSE� ISE� � PSE Z 7.2 17.8 8 9.5 SE3 I 47.8 �34.5 PS Z 1 SE I 2 MPa PRESSURE ZSP OUT ISA2 � SET MADE IN JAPAN IS� 8.75 Panel thickness 0.5 to 6 ZSM PF2� IF� Panel mount adapter + Front protective cover Data 11 17.8 8 9.5 42.4 �34.5 Panel thickness 0.5 to 6 16-2-11 R4.5 21 � � Series ZSE30/ISE30 Dimensions Panel fitting dimension Multiple (2 pcs. or more) horizontal mounting 1-pc. mounting MPa MPa MPa PRESSURE PRESSURE PRESSURE OUT OUT OUT � SET � SET � SET 31 x n pcs. + 3.5 x (n pcs. – 1) 0 31 –0.4 MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN Multiple (2 pcs. or more) vertical mounting 0 31–0.4 24 and up MPa PRESSURE OUT � SET MADE IN JAPAN MPa PRESSURE OUT � SET MADE IN JAPAN MPa PRESSURE OUT � SET MADE IN JAPAN 16-2-12 31 x n pcs. + 3.5 x (n pcs. – 1) 0 24 and up 31–0.4 � � � � � � Series ZSE30/ISE30 Specific Product Precautions 1 Be sure to read before handling. Operating Environment Handling Warning Warning 1. Do not drop, bump, or apply excessive 1. Our pressure switches are CE marked; ZSE� 2 impacts (980 m/s ) while handling. Although ISE� however, they are not equipped with surge the body of the sensor may not be damaged, protection against lightning. Lightning surge � � � PSE the internal parts of the sensor could be countermeasures should be applied directly damaged and lead to a malfunction. Z to system components as necessary. SE3 I 2. The tensile strength of the cord is 35 N. 2. Our pressure switches do not have an Applying a greater pulling force on it can PS explosion proof rating. Never use in the cause a malfunction. When handling, hold presence of an explosive gas as this may Z 1 the body of the sensor––do not dangle it SE I 2 cause a serious explosion. from the cord. 3. Do not use in an environment where static ZSP 3. Do not exceed the screw-in torque of 7 to 9 electricity can cause problems, otherwise N⋅m when installing piping. Exceeding this ISA2 system failure or malfunction may result. value may cause malfunctioning of the sensor. IS� 4. Do not use pressure sensors with corrosive Mounting and/or flammable gases or liquids. ZSM 5. Allow a sufficient margin of tube length in Caution PF2� piping in order to prevent application of 1. Mounting with panel mount adapter torsional, tensile or moment load to the IF� tubes and fittings. 6. When a brand of tubing other than SMC is Panel mount Data adapter used, make sure that the tolerance of the tube’s O.D. satisfies the following Panel mount adapter specifications. 1) Nylon tubing: ±0.1 mm or less Panel 2) Soft nylon tubing: ±0.1 mm or less 3) Polyurethane tubing: +0.15 mm or less, –0.2 mm or less To release push the clips outward as shown 7. The applicable fluid is air. Please consult on the picture, and pull with SMC if the switch is to be used with back towards you. Claw other types of fluids. 2. Mounting with bracket Mount a bracket to the body using two M3 x 5L mounting Connection screws and install on piping with hexagon socket head cap screws. The switch can be installed horizontally depending on Warning the installation location. 1. Incorrect wiring can damage the switch and Mounting screw � M3 x 5L cause a malfunction or erroneous switch output. Connections should be done while Bracket the power is turned off. Tightening torque for bracket mounting screw should be 0.5 to 0.7 N⋅m. 2. Do not attempt to insert or pull the pressure sensor or its connector when the power is � on. A switch output malfunction may occur. 3. Wire separately from power lines and high voltage lines, avoiding wiring in the same conduit with these lines. Malfunctions may occur due to noise from these other lines. � 4. If a commercial switching regulator is used, make sure that the F.G. terminal is grounded. 16-2-13 � � � � � � Series ZSE30/ISE30 Specific Product Precautions 2 Be sure to read before handling. Connection/Removal of Connector Piping • To connect the connector, insert it straight while • Cut the tube perpendicularly. pinching the lever, and then push the lever into the jack • Hold the tube and insert it into the One-touch fitting of the housing and lock it. carefully and securely all the way to the bottom. • To remove the connector, pull it straight out while applying pressure with your thumb to the lever and unhooking it from the jack. Tube Lever DC polarity indicator Lead wire (Brown) One-touch fitting Lead wire (Black) Lead wire (Blue) • Do not attempt to insert or pull the pressure sensor or its connector when the power is on. A switch output malfunction may occur. Regulating Pressure Range and Rated Pressure Range Caution Set the pressure within the rated pressure range. The regulating pressure range is the range of pressure that is possible in setting. The rated pressure range is the range of pressure that satisfies the specifications (accuracy, linearity, etc.) on the sensor. Although it is possible to set a value outside the rated pressure range, the specifications will not be guaranteed even if the value stays within the regulating pressure range. Pressure range Switch –100 kPa 0 100 kPa 500 kPa 1 MPa –100 kPa 100 kPa For vacuum/ ZSE30 low pressure –101 kPa 101 kPa 0 1 MPa For positive ISE30 –100 kPa pressure 1 MPa (–0.1 MPa) Rated pressure range of switch Regulating pressure range of switch 16-2-14 Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of Note 1) "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 , Note 2) JIS B 8370 and other safety practices. Operator error could result in injury or equipment damage. Caution : Operator error could result in serious injury or loss of life. Warning : In extreme conditions, there is a possible result of serious injury or loss of life. Danger : Note 1) ISO 4414: Pneumatic fluid power--General rules relating to systems. Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. The expected performance and safety assurance will be the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2.Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed. 2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply pressure for this equipment and exhaust all residual compressed air in the system. 3. Before machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod, etc. 4. Contact SMC if the product is to be used in any of the following conditions: 1. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 16-14-3 Common Precautions Be sure to read before handling. For detailed precautions on every series, refer to main text. 4. Use clean air Selection If the compressed air supply is contaminated with chemicals, cynthetic materials, corrosive gas, etc., it may lead to break Warning down or malfunction. 1. Confirm the specifications. Products represented in this catalog are designed for use in Operating Environment compressed air appllications only (including vacuum), unless otherwise indicated. Warning Do not use the product outside their design parameters. Please contact SMC when using the products in applications 1. Do not use in environments where the product other than compressed air (including vacuum). is directly exposed to corrosive gases, chemicals, salt water, water or steam. Mounting 2. Do not expose the product to direct sunlight for an extended period of time. Warning 3.Do not use in a place subject to heavy 1. Instruction manual vibrations and/or shocks. Install the products and operate them only after reading the 4. Do not mount the product in locations where it instruction manual carefully and understanding its contents. is exposed to radiant heat. Also keep the manual where it can be referred to as necessary. Maintenance 2. Securing the space for maintenance When installing the products, please allow access for Warning maintenance. 1. Maintenance procedures are outlined in the 3. Tightening torque operation manual. When installing the products, please follow the listed torque specifications. Not following proper procedures could cause the product to malfunction and could lead to damage to the equipment or machine. Piping 2. Maintenance work If handled improperly, compressed air can be dangerous. Caution Assembly, handling and repair of pneumatic systems should 1. Before piping be performed by qualified personnel only. Make sure that all debris, cutting oil, dust, etc, are removed 3. Drain flushing from the piping. Remove drainage from air filters regularly. (Refer to the 2. Wrapping of pipe tape specifications.) When screwing piping or fittings into ports, ensure that chips 4. Shut-down before maintenance from the pipe threads or sealing material do not get inside the Before attempting any kind of maintenance make sure the piping. Also, when the pipe tape is used, leave 1.5 to 2 thread supply pressure is shut of and all residual air pressure is ridges exposed at the end of the threads. released from the system to be worked on. 5. Start-up after maintenance and inspection Air Supply Apply operating pressure and power to the equipment and check for proper operation and possible air leaks. If operation Warning is abnormal, please verify product set-up parameters. 1. Operating fluid 6. Do not make any modifications to be product. Please consult with SMC when using the product in Do not take the product apart. applications other than compressed air (including vacuum). Regarding products for general fluid, please ask SMC about applicable fluids. 2. Install an air dryer, aftercooler, etc. Excessive condensate in a compressed air system may cause valves and other pneumatic equipment to malfunction. Installation of an air dryer, after cooler etc. is recommended. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the bowl will over flow and allow the condensate to enter the compressed air lines. If the drain bowl is difficult to check and remove, it is recommended that a drain bowl with the auto-drain option be installed. For compressed air quality, refer to “Air Preparation Equipment” catalog. 16-14-4 Quality Assurance Information (ISO 9001, ISO 14001) Reliable quality of products in the global market To enable our customers throughout SMC’s quality control system the world to use our products with Make customers our even greater confidence, SMC has first priority, offering them reliable and Create new products using the friendly service. obtained certification for international latest technology, and offer the finest standards “ISO 9001” and “ISO Produce the highest products in a timely manner. quality with the participation of all 14001”, and created a complete employees. structure for quality assurance and environmental controls. SMC Quality policies products pursue to meet its customers’ expectations while also considering company’s contribution in society. Market research Product planning After service Sales coordination New product evaluation Quality system Research Education Reliability design education Design Reliability testing Training Training of Development Quality management system New technical suppliers Production development ISO 9001 Process control Inspection, testing, etc. Initial production control This is an international standard for quality control and quality assurance. SMC has obtained a large Quality control activities number of certifications in Japan and overseas, providing assurance to our customers throughout the world. Environmental management system ISO 14001 This is an international standard related to environmental management systems and environmental inspections. While promoting environmentally friendly automation technology, SMC is also making diligent efforts to preserve the environment. 16-14-5 SMC Product Conforming to Inter SMC products complying with EN/ISO, CSA/UL standards are supporting CE Mark The CE mark indicates that machines and components meet essential requirements of all the EC Directives applied. It has been obligatory to apply CE marks indicating conformity with EC Directives when machines and components are exported to the member Nations of the EU. Once “A manufacturer himself” declares a product to be safe by means of CE marking (declaration of conformity by manufacturer), free distribution inside the member Nations of the EU is permissible. � CE Mark SMC provides CE marking to products to which EMC and Low Voltage Directives have been applied, in accordance with CETOP (European hydraulics and pneumatics committee) guide lines. � As of February 1998, the following 18 countries will be obliged to conform to CE mark legislation Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, Greece, Liechtenstein, Sweden, Spain, Denmark, Germany, Norway, Finland, France, Belgium, Portugal, Luxembourg � EC Directives and Pneumatic Components • Machinery Directive The Machinery Directive contains essential health and safety requirements for machinery, as applied to industrial machines e.g. machine tools, injection molding machines and automatic machines. Pneumatic equipment is not specified in Machinery Directive. However, the use of SMC products that are certified as conforming to EN Standards, allows customers to simplify preparation work of the Technical Construction File required for a Declaration of Conformity. • Electromagnetic Compatibility (EMC) Directive The EMC Directive specifies electromagnetic compatibility. Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission). • Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. • Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L. Such vessels require EC type examination and then CE marking. 16-14-6 SMC Product Conforming to International Standards national Standards you to comply with EC directives and CSA/UL standards. Mark of compliance Mark of compliance for CSA/UL for CSA � CSA Standards & UL Standards UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric products, and are defined to mainly prevent danger from electric shock or fire, resulting from trouble with electric products. Both UL and CSA standards are acknowledged in North America as the first class certifying body. They have a long experience and ability for issuing product safety certificate. Products approved by CSA or UL standards are accepted in most states and governments beyond question. Since CSA is a test certifying body as the National Recognized Testing Laboratory (NRTL) within the jurisdiction of Occupational Safety and Health Administration (OSHA), SMC was tested for compliance with CSA Standards and UL Standards at the same time and was approved for compliance with the two Standards. The above CSA NRTL/C logo is described on a product label in order to indicate that the product is approved by CSA and UL Standards. � TSSA (MCCR) Registration Products TSSA is the regulation in Ontario State, Canada. The products that the operating pressure is more than 5 psi (0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation. Products conforming to CE Standard With CE symbol for simple visual recognition In this catalog each accredited product series is indicated with a CE mark symbol. However, in some cases, every available models may not meet CE compliance. Please visit our web site for the latest selection of available models with CE mark. http://www.smcworld.com 16-14-7 SMC’s Global Service Network America Europe U.K. SMC Pneumatics (U.K.) Ltd. U.S.A. SMC Corporation of America Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN, Backinghamshire, U.K. 3011 North Franklin Road Indianapolis, IN 46226, U.S.A. TEL: 01908-563888 FAX: 01908-561185 TEL: 317-899-4440 FAX: 317-899-3102 GERMANY SMC Pneumatik GmbH CANADA SMC Pneumatics (Canada) Ltd. Boschring 13-15 D-63329 Egelsbach, Germany 6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada TEL: 06103-4020 FAX: 06103-402139 TEL: 905-812-0400 FAX: 905-812-8686 ITALY SMC Italia S.p.A. MEXICO SMC Corporation (Mexico), S.A. DE C.V. Via Garibaldi 62 I-20061 Carugate Milano, Italy Carr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo TEL: 02-9271365 FAX: 02-9271365 C.P. 36100, Silao, Gto., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 FRANCE SMC Pneumatique S.A. 1 Boulevard de Strasbourg, Parc Gustave Eiffel, Bussy Saint Georges, F-77600 CHILE SMC Pneumatics (Chile) S.A. Marne La Vallee Cedex 3 France Av. La Montaña 1,115 km. 16,5 P. Norte Parque TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvägen 29-31, S-141 05 Huddinge, Sweden ARGENTINA SMC Argentina S.A. TEL: 08-603-07-00 FAX: 08-603-07-10 Teodoro Garcia 3860 (1427) Buenos Aires, Argentina TEL: 011-4555-5762 FAX: 011-4555-5762 SWITZERLAND SMC Pneumatik AG Dorfstrasse 7, Postfach 117, CH-8484 Weisslingen, Switzerland BOLIVIA SMC Pneumatics Bolivia S.R.L. TEL: 052-396-3131 FAX: 052-396-3191 Avenida Beni Numero 4665 Santa Cruz de la Sierra-Casilla de Correo 2281, Bolivia AUSTRIA SMC Pneumatik GmbH (Austria) TEL: 591-3-3428383 FAX: 591-3-3449900 Girakstrasse 8, A-2100 Korneuburg, Austria TEL: 0-2262-6228-0 FAX: 0-2262-62285 VENEZUELA SMC Neumatica Venezuela S.A. Apartado 40152, Avenida Nueva Granada, Edificio Wanlac, SPAIN SMC España, S.A. Local 5, Caracas 1040-A, Venezuela Zuazobidea 14 Pol. Ind. Júndiz 01015 Vitoria, Spain TEL: 2-632-1310 FAX: 2-632-3871 TEL: 945-184-100 FAX: 945-184-510 PERU (Distributor) IMPECO Automatizacion Industrial S.A. IRELAND SMC Pneumatics (Ireland) Ltd. AV. Canevaro 752, Lince, Lima, Peru 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin, Ireland TEL: 1-471-6002 FAX: 1-471-0935 TEL: 01-403-9000 FAX: 01-466-0385 URUGUAY (Distributor) BAKO S.A. NETHERLANDS (Associated company) SMC Pneumatics BV Galicia 1650 esq. Gaboto C.P. 11200, Montevideo, Uruguay De Ruyterkade 120, NL-1011 AB Amsterdam, Netherlands TEL: 2-401-6603 FAX: 2-409-4306 TEL: 020-5318888 FAX: 020-5318880 BRAZIL SMC Pneumaticos Do Brasil Ltda. GREECE (Distributor) S.Parianopoulos S.A. Rua. Dra. Maria Fidelis, nr. 130, Jardim Piraporinha-Diadema-S.P. 7, Konstantinoupoleos Street 11855 Athens, Greece CEP: 09950-350, Brasil TEL: 01-3426076 FAX: 01-3455578 TEL: 11-4051-1177 FAX: 11-4071-6636 DENMARK SMC Pneumatik A/S COLOMBIA (Distributor) Airmatic Ltda. Knudsminde 4 B DK-8300 Calle 18 69-05 Apart. Aereo 081045 Santa Fe de Bogotá, Colombia Odder, Denmark TEL: 1-424-9240 FAX: 1-424-9260 TEL: 70252900 FAX: 70252901 16-14-20 SMC’s Global Service Network Europe Oceania/Asia AUSTRALIA SMC Pneumatics (Australia) Pty.Ltd. FINLAND SMC Pneumatics Finland OY 14-18 Hudson Avenue Castle Hill NSW 2154, Australia PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 02-9354-8222 FAX: 02-9894-5719 TEL: 09-8595-80 FAX: 09-8595-8595 NORWAY SMC Pneumatics Norway A/S NEW ZEALAND SMC Pneumatics (New Zealand) Ltd. Vollsveien 13C, Granfoss Năringspark N-1366 LYSAKER, Norway 8C Sylvia Park Road Mt.Wellington Auckland, New Zealand TEL: 67-12-90-20 FAX: 67-12-90-21 TEL: 09-573-7007 FAX: 09-573-7002 BELGIUM (Distributor) SMC Pneumatics N.V./S.A. TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. Nijverheidsstraat 20 B-2160 Wommelgem Belguim 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-355-1464 FAX: 03-355-1466 TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. HONG KONG SMC Pneumatics (Hong Kong) Ltd. ul. Konstruktorska 11A, PL-02-673 Warszawa, Poland 29/F, Clifford Centre, 778-784 Cheung, Sha Wan Road, Lai Chi Kok, Kowloon, TEL: 022-548-5085 FAX: 022-548-5087 Hong Kong TEL: 2744-0121 FAX: 2785-1314 TURKEY (Distributor) Entek Pnömatik San.ve Tic. Ltd. Sti Perpa Tic. Merkezi Kat:11 No.1625 80270 Okmeydani Istanbul, Türkiye SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. TEL: 0212-221-1512 FAX: 0212-221-1519 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 RUSSIA SMC Pneumatik LLC. 36/40 Sredny prospect V.O. St. Petersburg 199004, Russia PHILIPPINES SHOKETSU SMC Corporation TEL: 812-118-5445 FAX: 812-118-5449 Unit 201 Common Goal Tower, Madrigal Business Park, Ayala Alabang Muntinlupa, Philippines CZECH SMC Industrial Automation CZ s.r.o. TEL: 02-8090565 FAX: 02-8090586 Hudcova 78a, CZ-61200 Brno, Czech Republic TEL: 05-4121-8034 FAX: 05-4121-8034 MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. Lot 36 Jalan Delima1/1, Subang Hi-Tech Industrial Park, Batu 3 40000 Shah Alam HUNGARY SMC Hungary Ipari Automatizálási kft. Selangor, Malaysia Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 TEL: 03-56350590 FAX: 03-56350602 ROMANIA SMC Romania S.r.l. SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Str. Frunzei, Nr. 29, Sector 2, Bucharest, Romania Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, TEL: 01-3205111 FAX: 01-3261489 Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 SLOVAKIA SMC Priemyselná automatizáciá, s.r.o Nova 3, SK-83103 Bratislava CHINA SMC (China) Co., Ltd. TEL: 02-4445-6725 FAX: 02-4445-6028 7 Wan Yuan St. Beijing Economic & Technological Development Zone 100176, China TEL: 010-67882111 FAX: 010-67881837 SLOVENIA SMC Industrijska Avtomatilca d.o.o. THAILAND SMC Thailand Ltd. Grajski trg 15, SLO- 8360 Zuzemberk, Slovenia 134/6 Moo 5, Tiwanon Road, Bangkadi, Amphur Muang, Patumthani 12000, Thailand TEL: 07388-5240 FAX: 07388-5249 TEL: 02-963-7099 FAX: 02-501-2937 INDIA SMC Pneumatics (India) Pvt. Ltd. D-107 to 112, Phase-2, Extension, Noida, Dist. Gautaim Budh Nagar, U.P. 201 305, India TEL: (0120)-4568730 FAX: 0120-4568933 SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd. P.O.Box 240 Paardeneiland 7420 South Africa INDONESIA (Distributor) P.T. Riyadi Putera Makmur TEL: 021-511-7021 FAX: 021-511-4456 Jalan Hayam Wuruk Komplek Glodok Jaya No. 27-28 Jakarta 11180 Indonesia TEL: 021-625 5548 FAX: 021-625 5888 EGYPT (Distributor) Saadani Trading & Ind. Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt PAKISTAN (Distributor) Jubilee Corporation TEL: 3-548-50-34 FAX: 3-548-50-34 First Floor Mercantile Centre, Newton Road Near Boulton Market P.O. Box 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) Baccara Automation Control Kvutzat Geva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARABIA (Distributor) Assaggaff Trading Est. P.O. Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 16-14-21

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the ISE30-T1-25 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

CLEVIS, ROD, SGL-20MM LQA

SINGLE KNUCKLE JOINT

SINGLE KNUCKLE JOINT STAINLESS

SINGLE KNUCKLE JOINT

SINGLE KNUCKLE JOINT STAINLESS

product

REGULATOR