SL POWER / CONDOR POWER GPFM600-24

Description
None available.
Part Number
GPFM600-24
Price
Request Quote
Manufacturer
SL POWER / CONDOR POWER
Lead Time
Request Quote
Category
POWER SUPPLY
Datasheet
Extracted Text
GPFM600 Medical 600 Watt Global Performance Switchers FEATURES: Small package (12.00” x 5.50” x 3.09”) Power factor corrected to EN61000-3-2 Class A Operating range to 60°C ambient 85 to 264 Vac Input Medically Approved to UL2601-1, IEC601-1, CSA C22.2 No. 601.1.2 2 year warranty marked to LVD SPECIFICATIONS: Ac Input Inrush Current 85-264 Vac, 47-63 Hz single phase. Limit inrush current to 125% of maximum operating current. Turn on time of the power supply not to exceed 3 Output Power seconds over the full input voltage and frequency range. Continuous output power, 600 watts. EMI/EMC Compliance Hold-upTime All models include built-in EMI filtering to meet emissions 20 ms minimum from loss of ac input until output reaches requirements: 3% below nominal. EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions EN55011 Class B; FCC Class B Line and Load Regulation Static Discharge EN61000-4-2, 6 kV contact, 8 kV air ±1% over the entire input voltage and frequency range, RF Field Susceptibility EN61000-4-3, 3 V/meter and over the entire output current range. Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Minimum Load No minimum load required. Vibration and Shock Model meets MIL-STD 810E, method 514.4 Category. Overload Protection Current limit 105% minimum, 125% maximum of the Environmental specified full load current. Designed for 0 to 60°C operation, derate output current and total output power by 2.5% per °C above 50°C. Output Noise 100 mV pk-pk maximum @ 20 MHz bandwidth, Medical Leakage Current 150 µA under normal conditions. Maximum under single 50 mV pk-pk maximum ripple. fault conditions, 250 µA. Patient sink leakage with 120 Transient Response Vac, 60 Hz applied to any output with respect to the chassis will be less than 500 µA. Maximum of 5% change in Vout for a load change of 12.5 A. Recovers to ±1% within 500u sec. Medical Safety Agency Approved to UL2601-1, EN60601-1, CSA-C22.2 No. 601.1. Overvoltage Protection Built in, OVP crowbar reduces output voltage below nominal rating in less than 50 ms. Output voltage decay is dependent upon loading. DC Power Good Optocoupler isolated output indicates that the DC output is equal to or greater than 21.6 (-0 + 0.25) volts. This signal shall be driven when in the active ‘DC Good’ state. Efficiency Minimum of 75% under full load and input of 120 Vac 60 Hz. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 FAX 805-487-8911 www.condorpower.com 112 GPFM600 Medical 600 Watt Global Performance Switchers Output Commercial Model Output OVP Setpoint Total Regulation Noise P-P Maximum(A) Gc PFM600-24 2A 4 Vd 2V 5 2% 8.2 ± 1.2 1V 100 m GPFM600 MECHANICAL SPECIFICATIONS INPUT: J1 MOLEX P/N 43160-31-3 PIN 1: AC LINE PIN 2: AC NEUTRAL PIN 3: EARTH GROUND OUTPUT: J2 MOLEX P.N. 39-29-1147 14 PIN RIGHT ANGLE HEADER PIN 1: +24 V PIN 2: +24 V PIN 3: +24 V RETURN PIN 4: +24 V RETURN PIN 5: N/A PIN 6: AC GOOD PIN 7: AC GOOD RETURN PIN 8: +24 V PIN 9: +24 V PIN 10: +24 V RETURN PIN 11: +24 V RETURN PIN 12: N/A PIN 13: DC GOOD PIN 14: DC GOOD RETURN Dimensions: Inches Environmental Operating Non-operating Specification Millimeters o o T0 emperature (A) 0 to 6C0 -18 to +6 C A. Units should be allowed to warm up/operate under non-condensing conditions HH umidity (A)0H to 97% R 0 to 97% R before application of power. Cooling provided by internal fan— heatsink Sg hock (B) 20 40 g temperatures should not exceed 90ºC for extended periods in the installation. pk pk B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 At ltitude-t 500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz rms rms total 6 shocks. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 113
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the GPFM600-24 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods