SL POWER / CONDOR POWER GPFM115-13
Datasheet
Extracted Text
GPFM115 Medical 115 Watt Global Performance Switchers FEATURES: 115 Watts of continuous power with forced air Power factor corrected 74-81% efficiency Small package 3.3” x 5.25” x 1.5” inches Power fail warning, remote sense Optional cover with cooling fan Medical Approval to UL2601-1, CSA-C22.2 No. 601.1, EN60601-1 marked to LVD SPECIFICATIONS: Ac Input Transient Response 85-264 Vac, 47-63 Hz single phase Main Output 500 µs typical response time for return to within 0.5% of final value for a 50% load step change, Δi/Δt<0.2 A/µs. Output Power Maximum voltage deviation is 3.5%. Continuous rating is 80 W with unrestricted natural convection, or 115 W with forced convection. All models capable of 110% of Minimum Load rated power for 60 sec., 10% duty cycle maximum. No minimum load required to maintain output specifications. An abrupt change in output current from > 90% to < 2% load may Input Current cause a false triggering of the power fail signal. Maximum input current at 90 Vac, 60 Hz with full rated load is 1.7 A. Input current harmonic content meets the requirements of Voltage Adjustment IEC1000-3-2 for all load conditions at 230 Vac input. Active input Main output ±5%. circuitry provides high power factor of .96 min, .99 typical. Temperature Coefficient Inrush Current 0.03%/°C typical on all outputs. Inrush 240 Vac is less than 37 A, averaged over thr first ac half- cycle under cold start conditions. Limiting provided by internal Thermal Shutdown thermistors. Provided as a standard feature. Designed to protect unit from prolonged over temperature. Holdup Time 25 ms minimum from loss of ac input at full load. Fan Output An additional 12 Vdc, 100 mA output suitable for powering a dc Power Fail fan is included in all models. The fan output is referenced to +out. TTL / CMOS compatible output goes low (<0.5 V) 8 ms before Due to high pk-pk noise and low regulation, it is not output voltage drops more than 4% below nominal voltage upon recommended that this output be used for any other purpose. loss of ac power. The signal is factory set to trip before there is insufficient power stored in the primary to sustain the output. Input Protection Signal can sink 1.6 mA or source 400 mA at 2.7 V (Fan-out = 1). Internal ac fuse provided on all models. Fuse does not blow on overload or short circuit -- fuse blows only if a catastrophic Efficiency failure occurs in the unit. 74 to 81% depending upon model EMI/EMC Compliance DC Output Specification All models include built-in EMI filtering to meet the following Total regulation is the maximum deviation from the nominal emissions requirements: voltage for all steady state loading conditions. Peak ratings are EMC SPECIFICATION COMPLIANCE LEVEL for 60 s maximum duration, 10% duty cycle. Consult factory for Conducted Emissions EN55011, Class B; FCC Class B application assistance. Static Discharge EN61000-4-2, 6 kV contact 8 kV air RF Field Susceptibility EN61000-4-3, 3V/meter Remote Sense Fast Transients / Bursts EN61000-4-4, 2 kV, 5 kHz Provided as a standard feature on all models. Capable of Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. compensating for 0.25 V total of cabling losses. Conducted RF Susceptibility EN61000-4-6, 3V Voltage Sags & Surges EN61000-4-11 Overload Protection Fully protected against short circuit and output overload. Short Leakage Current circuit protection is cycling type power limit. Recovery after fault 90 µA normal conditions (132 Vac @ 60 Hz input) or 250 µA (264 is automatic. Consult factory for specific condition limits. Vac) single fault. Overvoltage Protection Medical Safety Built in on all models - See voltage and current chart for All models are Certified to be in compliance with the applicable individual model output limits. When OVP fires, the output requirements of UL 2601, CSA 22.2 No. 601.1-M90, IEC 601-1 converter stops providing input power to output. Output voltage (1988), EN 60601-1: 1990. (Consult factory for approval status) decay is dependent upon loading. Output Noise 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 FAX 805-487-8911 www.condorpower.com 50 GPFM115 Medical 115 Watt Single Output Medical Voltage Output Output Maximum (B) Output Peak Total Regulation OVP Setpoint Ripple/Noise Notes Model Output Adjustment Maximum (A) GPFM115-3.3 3.3 V 1A 2 A 2A 0 2% 5 224± .0% .6V 1C ±% 5 GPFM115-5 5.1 V ±% 5 1A 2 A 2A 0 2% 5 226V .±% 0.6 1C GPFM115-12 12 V ±% 5 6A .7 A 9A .6 1% 0.8 24 1±1% .1V 1C GPFM115-13 13 V ±% 5 6A .2 V 8A .8 9% .9 251±1% .1V 1C GPFM115-15 15 V ±% 5 5A .3 V 7A .7 8% .7 251±V 8.1% .5 1C GPFM115-24 24 V ±% 5 3A .3 A 44 .8 5% . 282±2% .5V 1C GPFM115-28 28 V ±% 5 2A .9 A 4A .1 4% .6 243±2% .8V 1C GPFM115-48 48 V ±% 5 1A .7 A 2A .4 2% .7 255V±% 4.0 1C Notes: A. Maximum continuous current rating for unrestricted convection cooling. B. Maximum continuous current rating with 150 LFM air or cover option. C. Add “-C” suffix for cover with fan option. GPFM115 MECHANICAL SPECIFICATIONS JI INPUT: (AMP P.C.B. HEADER P.N 640445-5) PIN 1) AC LINE PIN 2) = N/C PIN 3) = AC NEUTRAL PIN 4) = N/C PIN 5) = AC GROUND SIGNALS: J2 AMP P.C.B. HEADER P/N 640456-4 MATING CONNECTOR P/N 640621-4 PIN 1) POWER FAIL PIN 2) -SENSE PIN 3) +SENSE PIN 4) COMMON FAN: J4 AMP P.C.B. HEADER P/N 640456-2 MATING CONNECTOR P/N 640621-2 PIN 1) - PIN 2) + OUTPUT J3- 5A MAXIMUM CONTINUOUS CURRENT PER CONNECTOR PIN. AMP P.C.B. HEADER P/N 640445-8 PIN 1-4) +Vout PINS 5-8) RETURN OUTPUT-MATING CONNECTOR AMP P/N HOUSING 640250-8 CONTACT 770476-1 INPUT MATING CONNECTOR AMP P/N HOUSING 640250-5 CONTACT 770476-1 MAX. SCREW PROTRUSION THROUGH CHASSIS = 0.08” [2 MM], CHASSIS THICKNESS = 0.080” [2 MM] OPTIONAL COVER/FAN ASSEMBLY AVAILABLE P/N 09-115CF Environmental Operating Non-operating Specification A. Units should be allowed to warm up/operate under non-condensing conditions o o T0 emperature (A) 0 to 5C5 -40 to +8 C before application of power. Derate output current and total output power by 2.5% per °C above 50°C. For operation in a confined space, moving air may be required. HH umidity (A)0H to 95% R 0 to 95% R Under all conditions, the cooling vs. load profile should be such that chassis temperatures do not exceed 90°C for extended periods. Sg hock (B) 20 40 g pk pk B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 At ltitude-t 500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz rms rms total 6 shocks. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 51
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the GPFM115-13 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods