Part Number | GPC80-24 |
---|---|
Manufacturer | SL POWER / CONDOR POWER |
Category | AC/DC POWER SUPPLY |
Price | Request Quote |
Lead Time | Request Quote |
SL POWER/CONDOR POWER GPC80-24 Power Supply, Switching; 80 W; 85 to 264 VAC; 24 V; 2.3 A (Max.); 3.4 A (Max.)
Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.
Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.
Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.
Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.
Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.
Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.
After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.
Elite.Parts is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.
Do you need a GPC80-24? We can help you find it at a competitive price!
Ac Input | 85-264 Vac, 47-63 Hz single phase. |
---|---|
Commercial Leakage Current | 0.7 mA 254 Vac @ 60 Hz input. |
Commercial Safety | Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file #E135803 commercial; CSA #LR46516 all. The output(s) are intended for safety earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV under normal and single fault conditions. |
Efficiency | 70% at full rated load, nominal input voltage, depending on model and load distribution. |
EMI/EMC Compliance | All models include built-in EMI filtering to meet the following emissions requirements:EMI SPECIFICATIONS COMPLIANCE LEVEL, Conducted Emissions GPC80 EN55022 Class B; FCC Class B, Conducted Emissions GPM80 EN55011Class B; FCC Class B, Static Discharge EN61000-4-2, 6 kV contact, 8 kV air, RF Field Susceptibility EN61000-4-3, 3 V/meter, Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz, Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Line Frequency Harmonics EN61000-3-2 Class A |
Environmental | Designed for 0 to 50°C operation at full rated output power; derate output current and total output power by 2.5% per °C above 50°C. See Environmental and Packaging Specifications on next page. |
Hold-Up Time | 20 ms minimum from loss of ac input at full load, nominal line (115 Vac). |
Input Current | Maximum input current at 120 Vac, 60 Hz with full rated output load: 2.3 A |
Input Protection | Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit. |
Inrush Current | Inrush is limited by internal thermistors. Inrush at 240 Vac under cold start conditions will not exceed 34 A. Temperature Coefficient 0.03%/°C typical on all outputs. |
Medical Commercial Safety | Approved to UL2601-1, CSA-C22.2 No. 601.1 Level 3 and IEC601.1. UL file E116994; CSA #LR46516. The output(s) are intended for safety earthed Signal Output and Intermediate Circuits only. The output(s) are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and single fault conditions. |
Medical Leakage Current | 35 µA 254 Vac @ 60 Hz input. |
Output Noise | 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. |
Output Power | 80 W continuous, 110 W with air flow. Peak ratings are for 60 s maximum duration, 10% duty cycle. During peak load condition, output regulation may exceed total regulation limits. |
Overload Protection | Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on outputs 1 & 2; foldback type on outputs 3 & 4. Recovery after fault is automatic. Factory set to begin power limiting at 120 W. See output ratings chart for additional notes or conditions. |
Overvoltage Protection | Main outputs: 124% ± 12% typical. |
Power Fail (optional) | TTL- or CMOS-compatible output goes low ( |
Remote Sense | Provided as a standard feature on single-output models. |
Temperature Coefficient | 0.03%/°C typical on all outputs. |
Transient Response | Main output—500 µs typical response time for return to within 0.5% of final value for a 50% load step change. ?i/?t |
Voltage Adjustment | Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2. |
Download "GPC80P.pdf" (253 KiB)
GPC80 Commercial/GPM80 Medical 80 Watt Global Single and Multiple Output Performance Switchers FEATURES: Wide-range ac input 85-264 Vac 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Commercial Approved to UL1950, IEC950, EN60950 and CSA22.2-234 L3 Medical Approved to UL2601-1, IEC601-1 and CSA22.2 No. 601.1 Complies with EN61000-3-2 Class A marked to LVD SPECIFICATIONS: Ac Input trip on 84 to 94 Vac brown-out depending upon incoming line impedance and distortion. Other settings are avail- 85-264 Vac, 47-63 Hz single phase. able to the user through adjustment of built-in potentiom- eter (consult factory for assistance). For Power fail option, Input Current add -PF after model number. Maximum input current at 120 Vac, 60 Hz with full rated output load: 2.3 A Output Noise 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential Hold-Up Time mode. Measured with noise probe directly across output 20 ms minimum from loss of ac input at full load, nominal terminals of the power supply. line (115 Vac). Transient Response Output Power Main output—500 µs typical response time for return to 80 W continuous, 110 W with air flow. Peak ratings are for within 0.5% of final value for a 50% load step change. Δi/ 60 s maximum duration, 10% duty cycle. During peak Δt<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/ load condition, output regulation may exceed total shutdown overshoot less than 3%. regulation limits. Remote Sense Overload Protection Provided as a standard feature on single-output models. Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit on Voltage Adjustment outputs 1 & 2; foldback type on outputs 3 & 4. Recovery Built-in potentiometer adjusts voltage ±5% on outputs 1 & 2. after fault is automatic. Factory set to begin power limiting at 120 W. See output ratings chart for additional notes or EMI/EMC Compliance conditions. All models include built-in EMI filtering to meet the following emissions requirements: Overvoltage Protection EMI SPECIFICATIONS COMPLIANCE LEVEL Main outputs: 124% ± 12% typical. Conducted Emissions GPC80 EN55022 Class B; FCC Class B Conducted Emissions GPM80 EN55011Class B; FCC Class B Efficiency Static Discharge EN61000-4-2, 6 kV contact, 8 kV air 70% at full rated load, nominal input voltage, depending RF Field Susceptibility EN61000-4-3, 3 V/meter on model and load distribution. Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Input Protection Line Frequency Harmonics EN61000-3-2 Class A Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit. Commercial Leakage Current 0.7 mA 254 Vac @ 60 Hz input. Inrush Current Inrush is limited by internal thermistors. Inrush at 240 Vac Commercial Safety under cold start conditions will not exceed 34 A. Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and EN60950. UL file #E135803 commercial; CSA Temperature Coefficient #LR46516 all. The output(s) are intended for safety 0.03%/°C typical on all outputs. earthed Signal Output and Intermediate Circuits only. All dc outputs are SELV under normal and single fault Environmental conditions. Designed for 0 to 50°C operation at full rated output power; derate output current and total output power by Medical Leakage Current 2.5% per °C above 50°C. See Environmental and 35 µA 254 Vac @ 60 Hz input. Packaging Specifications on next page. Medical Commercial Safety Power Fail (optional) Approved to UL2601-1, CSA-C22.2 No. 601.1 Level 3 TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms and IEC601.1. UL file E116994; CSA #LR46516. The before output voltage drops more than 4% below nominal output(s) are intended for safety earthed Signal Output voltage upon loss of ac power. The signal is factory set to and Intermediate Circuits only. The output(s) are not acceptable for patient connection without additional isolation. All dc outputs are SELV under normal and single fault conditions. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 FAX 805-487-8911 www.condorpower.com 44 GPC80 Commercial/GPM80 Medical 80 Watt Single and Multiple Output Commercial Medical Output Output Output Total Model Model Output No. Output Minimum Maximum (B) Maximum (C) Output Peak Noise P-P Regulation (A) GPC80A GPM80A 1 +5 V 1.0 A 12 A 12 A 16 A 50 mV 2% 2 +12 V 0 A 3 A 4 A 5 A 120 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 +12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% GPC80B GPM80B 1 + 5 V 1.0 A 12 A 12 A 16 A 50 mV 2% 2 +12 V 0 A 3 A 4 A 5 A 120 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 -5 V 0 A 1 A 1.2 A 1.2 A 50 mV 3% GPC80C GPM80C 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +12 V 0 A 3 A 4 A 5 A 120 mV 2% 3 -15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% 4 +15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% GPC80D GPM80D 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +24 V 0 A 2 A 3 A 4 A 240 mV 2% 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 +12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% GPC80E GPM80E 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +24 V 0 A 2 A 3 A 4 A 240 mV 2% 3 -15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% 4 +15 V 0 A 1 A 1.2 A 1.2 A 150 mV 3% GPC80P GPM80P 1 +5 V 1 A 12 A 12 A 16 A 50 mV 2% 2 +24 V 0.5 A 3.5 A 4.5 A 4.5 A 400 mV +10%/-5% (D) 3 -12 V 0 A 1 A 1.2 A 1.2 A 120 mV 3% 4 +12 V 0 A 2 A 2 A 2.5 A 120 mV 3% GPC80-5 GPM80-5 1V5A0A1A 6 2A 0 2V 2 5% 0 m 2 GPC80-12 GPM80-12 1V1A 2 0A6A .7 9A .2 9V .2 1% 20 m 2 GPC80-15 GPM80-15 1V1A 5 0A5A .3 7A .3 7V .3 1% 50 m 2 GPC80-24 GPM80-24 1V2A 4 0A3A .4 4A .6 4V .6 2% 40 m 2 GPC80-28 GPM80-28 1V2A 8 0A2A .9 3A .9 3V .9 2% 80 m 2 GPC80-48 GPM80-48 1V4A 8 0A1A .7 2A .3 2V .3 4% 80 m 2 A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. Ratings for unrestricted natural convection cooling; output 1 & 2 combined load not to exceed 14A continuous; total power = 80W. C. Ratings with 26 cfm forced air cooling; output 1 & 2 combined load not to exceed 16A continuous; total power = 110W. D. To maintain these regulation conditions, the +5V current must be at least 1/4 of V2 and not greater than 5 times the V2 current. Requires +5V to be adjusted within ±1% with at least a 1A load to maintain regulation on this input. E. For Power Fail option, add -PF after the model number. GPC80/GPM80 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o Ts emperature (A)S5 ee individual spec -40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions HH umidity (A)0H to 95% R 0 to 95% R before application of power. B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 Sg hock (B) 20 40 g pk pk orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. At ltitude-t 500 to 10,000 f -500 to 40,000 f C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 45
Any product names, logos, brands, and other trademarks or media featured or referred to on Elite.Parts are the property of their respective owners.
GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.
All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.