SL POWER / CONDOR POWER GLM65-15
Datasheet
Extracted Text
GLC65 Commercial/GLM65 Medical 65 Watt Single Output Global Performance Switchers FEATURES: 3 4.1 W/in Compact (3.0" x 5.0" x 1.06") Ultra-high efficiency (up to 94%) using patented technology Meets harmonic requirements of IEC1000-3-2, Class A Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) 2-year warranty Exempt from line harmonics standard EN61000-3-2 Commercial Approved to UL1950, IEC950, EN60950, CSA22.2 No. 950 Medical Approved to UL2601, EN60601, CSA22.2 SPECIFICATIONS: No. 601.1 Multiple output versions also available Ac Input 90-264 Vac, 47-63 Hz single phase.marked to LVD Input Current Maximum input current at minimum output voltage and output overload will be less than 1.7 A. Meets input current harmonic requirements of IEC1000-3-2. Inrush Current Output Power Inrush is limited by internal thermistor. The inrush at 240 Normal continuous output power is 65 W, 75 W peak for Vac, averaged over the first ac half-cycle under cold start 60 s. The 3.3 Vdc unit is 36.3 W and the 5 Vdc unit is 55 W conditions will not exceed 37A. continuous. EMI/EMC Compliance Hold-Up Time All models include built-in EMI filtering to meet the 20 ms from loss of ac input at 65 W load, from 120 Vac following emissions requirements: input. EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions GLC65 EN55022 Class B; FCC Class B Overload Protection Conducted Emissions GLM65 EN55011 Class B: FCC Class B Fully protected against short circuit and output overload. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air Short circuit protection is cycling type power limit. RF Field Susceptibility EN61000-4-3, 3 V/meter Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Output Noise Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with scope probe directly across output Commercial Leakage Current terminals of the power supply with load terminated with Under normal conditions, leakage current is 425 µA with 0.1 µF capacitor. 132 Vac @ 60 Hz input. Transient Response Commercial Safety Main output: 500 µs typical response time for return to All GLC models are approved to UL1950, CSA22.2 No. within 0.5% of final value for a 50% load step within the 950, IEC950 and EN60950. regulation limits of minimum and maximum load, Δi/Δt<0.2 A/µs. Maximum voltage deviation is 3.5%. Medical Leakage Current Startup/shutdown overshoot less than 3%. The maximum leakage current under single-fault condi- tions (254 Vac @ 50 Hz) is 120 µA. Under normal Voltage Adjustment conditions, leakage current is 31µA with 132 Vac @ 60 Hz Adjustable potentiometer capable of ±5% change from input. nominal setting. Medical Safety Efficiency All GLM models are approved to UL2601, CSA22.2 No. 82 to 94% minimum at full rated load, nominal input 601, IEC601-1 and EN60601. Consult factory for approval voltage, depending on model. status. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 • 805-486-4565 FAX 805-487-8911 www.condorpower.com 36 GLC65 Commercial/GLM65 Medical 65 Watt Single Output Commecial Medical Output Current Total Regulation V1 Adjustment V1 OVP Setpoint Ripple and Noise Model Model GLC65-5 GLM65-5 5A .1 V 1% 1 2%±V 5 6% .2 ± 0.6 1 GLC65-12 GLM65-12 1A 2 V 5% .5 2%±V 5 1% 4 ± 1.1 1 GLC65-15 GLM65-15 1A 5 V 4% .3 2%±V 5 1% 8.5 ± 1.5 1 GLC65-18 GLM65-18 1A 8 V 3% .6 2%±0 5 2% 1.7 ± 2. 1 GLC65-24 GLM65-24 2A 4 V 2% .7 2%±V 5 2% 8 ± 2.5 1 GLC65-28 GLM65-28 2A 8 V 2% .3 2%±V 5 3% 4 ± 2.8 1 GLC65-48 GLM65-48 4A 8 V 1% .35 2%±V 5 5% 5 ± 4.0 1 GLC65/GLM65 MECHANICAL SPECIFICATIONS Environmental Operating Non-operating Specification o o T0 emperature (A) 0 tp 5C5 -40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions HH umidity (A)0H to 95% R 0 to 95% R before application of power. Derate output current and total output power by 2.5% Sg hock (B) 20 40 g per °C above 50°C. pk pk B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 At ltitude-t 500 to 10,000 f -500 to 40,000 f orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, 2 2 Vg ibration (C) 1.5 , 0.003 g/g Hz 5 , 0.026 g /Hz rms rms total 6 shocks. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 37
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the GLM65-15 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods