MA-5200 Series TAC MA-5300 Series 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require a return to the normal position upon power interruption. Features • Two-position actuators controlled by an SPST MA-521X Series controller Valve Actuator Spring return 24 Vac, 120 Vac, and 240 Vac models are available An actuator with the part number suffix "-500" has a built-in, adjustable, SPDT auxiliary switch Available in damper models or base models that require damper or valve linkage Die cast lower housing with 1/2" conduit opening and painted steel upper housing Hydraulic actuator with oil-immersed motor and pump MA-533X Series Damper Actuator Applicable Literature TAC Pneumatic Products Catalog, F-27383 TAC Environmental Controls Cross-Reference Guide, F-23638 TAC Environmental Controls Reference Manual, F-21683 TAC Environmental Controls Application Manual, F-21335 General Instructions Sheet F-19069, for Valve LInkages AV-600 and AV-601 Material Safety Data Sheet MSDS-3, (Until Feb. 1989) Material Safety Data Sheet MSDS-12 (Currently) Printed in U.S.A. 8-06 Copyright 2006 TAC All Rights Reserved. F-15070-13 SPECIFICATIONS Actuator Inputs Control Circuit: Two wire, SPST. Power Input: Refer to Table-1 and Table-2. Connections: Color-coded 4 ft. (1.2 m) leads. Actuator Outputs Electrical: Auxiliary Switch (MA-5xxx-500), 10 Amps, 120/240 Vac adjustable SPDT, factory set to close the N.O. contact at the retracted end of stroke. Mechanical: Stroke, Damper Approximately 2" (51 mm) from fully retracted to fully extended (includes AM-601 linkage). Valve Approximately 9/16" (14.3 mm) from fully retracted to fully extended. Nominal Damper Area, Actuator sizing should be done in accordance with damper manufacturer’s specifications. Environment Ambient Temperature Limits: Shipping & Storage, -40 to 140° F (-40 to 60° C). Operating, Damper 0 to 140° F (-18 to 60° C). Valve Refer to Table-3. Humidity: 5 to 95% RH, non-condensing. Location: NEMA Type 1. Agency Listings: UL 873, Underwriters Laboratories (File # E9429 Category Temperature-Indicating and Regulating Equipment). CSA, Certified for use in Canada by Underwriters Laboratories. Canadian Standard C22.2 No. 24-93. European Community, EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). Table-1 Model Chart for Damper Actuators. Timing in Seconds Actuator Power Input @ 72° F (22° C) Torque Rating Part AC (Extend & Retract) To Extend Retract Number Voltage lb.-in. (N-m) Hz VA Watts (No Load on Power +10/ Stroke) Loss -15% MA-5330 120 50 60 18 14 60 15 20 (2.3) MA-5333 24 2 Copyright 2006 TAC All Rights Reserved. F-15070-13 Table-2 Model Chart for Valve Actuators. Also for Damper Actuators with Field Assembled Damper Linkages. Timing in Seconds @ a Actuator Power Input Required Linkage 72° F (22° C) 10 Amps Part Number Aux AC To Extend Retract on Switch Voltage Hz VA Watts (No Load Power Damper Valve +10/-15% Stroke) Loss MA-5210 No 120 MA-5210-500 Yes MA-5211 No AV-600 b 240 50 60 18 14 60 15 AM-601 c AV-601 MA-5211-500 Yes MA-5213 No 24 MA-5213-500 Yes a Damper models are provided with factory-installed damper linkages. Only base models require separately-ordered linkages. b With the installation of the AM-601 damper linkage, these valve actuators become functionally the same as the damper actuators listed in Table-1. Refer to Table-1 for the torque rating. c May be required for steam and hot water. Refer to Table-3. Table-3 Maximum Allowable Ambient Air Temperature for Valve Actuators. Maximum Ambient Temperature Maximum Temperature of Media of MA-521x Series in the Valve Body (Check the Rating of the Valve) AV-600 (Only) AV-600 and AV-601 °F (°C) °F (°C) °F (°C) 366 (186) 90 (32) 90 (32) 340 (171) 100 (38) 100 (38) a 281 (138) 115 (46) 140 (46) a a 181 (83) 140 (60) 140 (60) a a 80 (26) 140 (60) 140 (60) a Maximum ambient temperature of the actuator must never exceed 140° F (60° C). ACCESSORIES Common 11-1612 1/2" conduit bushing Damper Linkages AM-111 Crank arm for 5/16" (8 mm) diameter damper shaft AM-112 Crank arm for 3/8" (10 mm) diameter damper shaft AM-113 Crank arm for 1/2" (13 mm) diameter damper shaft AM-115 Crank arm for 7/16" (11 mm) diameter damper shaft AM-122 Linkage connector straight type AM-123 Damper clip AM-125 5/16" diameter x 20" damper rod AM-125-048 5/16" diameter x 48" damper rod AM-132 Ball joint connector AM-161-3 Damper linkage kit AM-601 Device includes mounting bracket, damper linkage with spring, and AM-122 straight connector. Required to modify (MA-521x series) valve actuators into 2" (51 mm) stroke damper actuators. AM-602 Spacer Valve Linkages AV-600 Valve linkage AV-601 Valve linkage extension for hot water and steam applications; use with AV-600 TOOLS (factory-available) TOOL-12 Wrench for adjustment of auxiliary switch TOOL-19 Spring compression tool for AV-600 TOOL-37 1-5/8" (41 mm) open-ended wrench F-15070-13 Copyright 2006 TAC All Rights Reserved. 3 TYPICAL APPLICATIONS (wiring diagrams) Brown (N.O.) Aux. Switch Leads Orange (N.C.) (-500 Actuators only) Red/White (C) MA-5XXX Actuator Thermostat or Switch L1 Black L2 Green NOTE: Actuator extends when Actuator Voltage Color(s) of contacts are closed and retracts Vac L2 Lead when contacts are open 24 Black/Blue 120 White 240 White/Black Figure-1 Typical Wiring for MA-5xxx Series Actuators. INSTALLATION Inspection Inspect the package for damage. If damaged, notify the appropriate carrier immediately. If undamaged, open the package and inspect the device for obvious damage. Return damaged products. RequirementsJob wiring diagrams. Tools (not provided): – Digital Volt-ohm Meter (DVM). – Appropriate drill and drill bit for mounting screws. – Appropriate screw drivers and wrenches. – TOOL-12, Wrench for adjustment of auxiliary switch. – TOOL-19, Spring compression tool for AV-600. – TOOL-37, 1-5/8" (41 mm) open-ended wrench. Training: Installer must be a qualified, experienced technician. Warning: Disconnect power supply before installation to prevent electrical shock and equipment damage. Make all connections in accordance with the wiring diagram and in accordance with national and local electrical codes. Use copper conductors only. Caution: Static charges produce voltages high enough to damage the electronic components. Follow static electricity precautions when installing or servicing the device(s). Discharge any static electricity you may have accumulated by using wrist straps, or by touching a known, securely grounded object. Do not exceed the ratings of the device(s). Do not apply power to the unit unless the damper linkage and/or the valve assembly have been installed. Avoid locations where excessive moisture, corrosive fumes, or vibration is present. Do not install insulation on any part of the actuator. 4 Copyright 2006 TAC All Rights Reserved. F-15070-13 Mounting Do not twist or exert any force on the actuator housing during installation. Either turn the base by hand or, if necessary, use a 1-5/8" (41 mm) open-ended wrench (TOOL-37) on the flats provided on the actuator base or the valve body mounting nut. Refer to Figure-2. Housing Base Wrench Flats Figure-2 Housing and Base Location. Dampers The actuator is not position sensitive. It can be mounted in any position in a NEMA Type 1 location. Valves Allow 3" (76 mm) of clearance above the actuator valve assembly for the removal and reattachment of the actuator to the installed valve. 1. Install all two-way valves so that they close against the flow. An arrow on the valve body or tag indicates proper flow direction. 2. Always install three-way mixing valves with two inlets and one outlet. 3. Always install three-way diverting valves with one inlet and two outlets. Caution: For steam applications only, mount the actuator above the valve body at 45° from vertical. 4. Actuators can be mounted in any upright position above the centerline of the valve body. Wiring Requirements Power Leads The low voltage (24 Vac) power leads may be connected to a Class 2 circuit if routed separately from Class 1 circuit wiring. The line voltage (120 and 240 Vac) leads must be connected to a Class 1 circuit. Refer to Figure-7. Refer to Table-4 for the maximum length of run for the power leads, for the given wire size(s). To determine the allowable maximum power lead run when wiring multiple actuators, divide the maximum run shown in Table-4 by the number of actuators on the run. Refer to Figure-3 for further details. F-15070-13 Copyright 2006 TAC All Rights Reserved. 5 Table-4 Power Wiring Data. Actuator Actuator Model Power Lead Wire Size Maximum Wire Run Voltage Number Colors GA ft. (m) Vac MA-5210 120 Black & White 14 3,500 (1,067) MA-5210-500 MA-5211 240 Black & White/Black 14 6,000 (1,829) MA-5211-500 MA-5213 14 300 (91.5) 24 Black & Black/Blue 12 480 (146.3) MA-5213-500 MA-5330 120 Black & White 14 3,500 (1,067) MA-5330-500 MA-5333 14 300 (91.5) 24 Black & Black/Blue 12 480 (146.3) MA-5333-500 24 Vac Black/Blue To Vac Power 120 Vac White 240 Vac White/Black Black Green MA-52XX Green MA-52XX To Additional MA-52XX Series Actuators Figure-3 Wiring of Multiple MA-52xx Series Actuators to Single Power Source. Auxiliary Switch Leads The low voltage (24 Vac) auxiliary switch leads may be connected to a Class 2 circuit. The line voltage (120 Vac and 240 Vac) auxiliary switch leads must be connected to a Class 1 circuit and routed separately from any Class 2 circuit wiring. Refer to Figure-7. Wiring Connections Wire Lead Connections (No Conduit) Make connections as required. Refer to Figure-1 for a wiring diagram of a typical application. Refer to Figure-4 for a view of the actuator. Note: The cover plate and screw supplied with the actuator are not required with this method. 6 Copyright 2006 TAC All Rights Reserved. F-15070-13 Figure-4 Connection of Wire Leads (No Conduit). Installing 3/8" Flexible Conduit Onto One or Both Sides of Actuator Flexible conduit may be installed onto one or both sides of the actuator (refer to Figure-6 and Figure-7). Install each conduit as follows: 1. Determine the side of the actuator to which the flexible conduit is to be attached. 2. Remove the knockout (e.g., with channel lock pliers) on the selected side of the actuator. Refer to Figure-5. 3. Make the required connections. Refer to Figure-1 for a wiring diagram of a typical application. Base Knockout Figure-5 Removal of Knockout on Actuator Base. 4. Slip the conduit onto the base, over the ribs. Refer to Figure-6 and Figure-7. 5. If flexible conduit is to be installed on both sides of the actuator, repeat the preceding steps to install the second conduit. Base Cover Plate Ribs or Figure-6 Flexible Conduit Installation to Either Side of Actuator. F-15070-13 Copyright 2006 TAC All Rights Reserved. 7 Low voltage motor leads may be connected Typical for 24 Vac to a Class 2 circuit if routed separately from models (MP-5XX3) wiring that is other than Class 2 4 x 4 Conduit Box Transformer (AM-610 shown) Cover Plate Leave Knockout in place The line voltage auxiliary switch leads Note: Class 2 circuit wiring must be routed must be separated from Class 2 motor separately from the wiring from other circuits. circuit wiring. Do not route Class 2 circuit wiring in the same conduit box with the line voltage transformer Figure-7 MA-5200 and MA-5300 Series Wiring with Separation for Class 2 and Line Voltage Circuits. 6. Install the cover plate with two screws. The cover plate and two screws are supplied with the actuator. Installing Conduit Box Onto Actuator Installation of a conduit box allows for the attachment of one or more thin wall conduits to the actuator. This procedure also serves as an optional method for connecting flexible conduit to the actuator. 1. Remove the knockout from the cover plate supplied with the actuator. Refer to Figure-8. Cover Plate Knockout Figure-8 Cover Plate Knockout Removal. 2. Slip the actuator’s leads through a standard 1/2” conduit bushing (Figure-9, not supplied) and the knockout hole in the cover plate. Refer to Figure-10. 1/8" (3 mm) maximum Use TAC 11-1612, Bridgeport 1102-DC, or equivalent Figure-9 1/2" Conduit Bushing. 8 Copyright 2006 TAC All Rights Reserved. F-15070-13 1/2" Conduit Bushing (not supplied) Base Cover Plate Figure-10 Conduit Bushing and Cover Plate Installation. 3. Seat the conduit bushing in the base. 4. Install the cover plate, using the two screws provided. 5. Loosely install the conduit box and the locknut onto the conduit bushing. Refer to Figure-11. Figure-11 Attachment of Conduit Box to Conduit Bushing. 6. Tighten the locknut as follows: a. Tilt the conduit box approximately 30 degrees counterclockwise, relative to the actuator. b. Finger-tighten the locknut against the conduit box. c. Rotate the conduit box clockwise until it is aligned with the actuator. This will tighten the locknut. 7. Make the required wiring connections. Refer to Figure-1 for a wiring diagram of a typical application. 8. Install the conduit to the conduit box as required. Note: As shown in Figure-10, the hole in the cover plate of the actuator conduit housing is sized to accept both British standard M20 (20 mm) conduit connectors and 20 mm-to-PG16 adaptors for use with DIN PG16 connectors. (Follow the steps for installing the conduit box to the actuator.) F-15070-13 Copyright 2006 TAC All Rights Reserved. 9 Linkage Assembly Damper Note: Each actuator in the MA-5x3x series is provided with a factory-installed damper linkage. No separately-ordered linkage is required. Caution: Do not twist or exert any force on the actuator housing during installation. Either turn the base by hand or, if necessary, use a 1-5/8" (41 mm) open-ended wrench (TOOL- 37) on the flats provided on the actuator base, or on the valve body mounting nut. (Refer to Figure-2.) 1. Determine the best mounting position for the actuator as follows: a. Determine, from the system requirements, if the damper should spring-return to the open position (refer to Figure-12) or closed position (refer to Figure-13) whenever power is lost to the actuator. For example, an outside air damper actuator is typically linked so as to retract (spring-return) to the damper’s fully closed position (safe position). Spring returns open on loss of power Open Close Retract Extend Damper Shaft Figure-12 Dampers Open When Actuator Retracts (Spring-Returns Open on Power Loss). Spring returns open on loss of power Extend Retract Open Close Damper Shaft Figure-13 Dampers Open When Actuator Extends (Spring-Returns Closed on Power Loss). b. Be sure to allow adequate working space around the actuator mounting location to mount the actuator, link it to the damper, and wire it into the system (refer to Figure-20). c. If possible, select a mounting position such that, at mid-stroke, the actuator crank arm and the damper crank arm on the drive shaft are each at a 90° angle to the damper rod (Refer to Figure-14). This is the recommended mounting position. It may be necessary to swivel the actuator linkage to arrive at this mounting location. 10 Copyright 2006 TAC All Rights Reserved. F-15070-13 Mid-Stroke Position Mounting Actuator Angle from Mid-Stroke Points Crank Arm Position (See Table) Angle Position of Required from Linkage Damper Mid-Stroke Connector Rotation Position 60° 30° 2" (50 mm) 90° 45° 1-1/2" (38 mm) Mounting Points Damper Rod Linkage Position of Linkage Connectors Connector (See Table) Damper Damper Crank Arm Shaft Figure-14 Recommended Actuator/Damper Mounting. d. Consider the damper rod length when positioning the actuator in relation to the damper. A damper rod that is too long is not rigid enough to provide good control, while a damper rod that is too short makes adjustment difficult. 2. Position the actuator on the duct and mark the location of the mounting holes, using the actuator mounting bracket as a template (refer to Figure-20). 3. Drill or punch the mounting holes in the duct for the appropriate 1/4" (6 mm) diameter screws or bolts. The actuator must be mounted firmly enough to prevent excessive actuator movement under normal damper loading. If there is excessive actuator movement, the damper may not fully open or close. 4. Mount a ball joint connector in the slot on the damper crank arm. To achieve 90° of damper rotation, position the connector 1-1/2" (38 mm) from the centerline of the shaft hole on the crank arm. For 60° of damper rotation, position the connector 2" (50 mm) from the shaft hole centerline. Typically, 60° to 70° of rotation (maximum is 90°) is sufficient to permit almost maximum air flow through the dampers. (Refer to Figure-14). 5. Rotate the damper to its open position. Install and secure the damper crank arm (with ball joint connector) to the damper shaft, positioning the crank arm as follows (Refer to Figure-14): a. To achieve 60° of damper rotation, position the crank arm so that it is pointed towards the actuator at 30° from its mid-stroke position. b. To achieve 90° of damper rotation, position the crank arm so that it is pointed towards the actuator at 45° from its mid-stroke position. 6. Install the damper rod by sliding one end through the ball joint connector mounted on the damper crank arm, and the other end through the straight connector on the actuator crank arm. Tighten the nut on the actuator crank arm’s straight connector. Cut off any excess length of damper rod. 7. For normally open dampers, tighten the nut on the ball joint connector on the damper crank arm. To ensure that the damper closes completely, make adjustments so that the actuator is 1/16" (1.6 mm) from the extended end of stroke when the damper closes. Verify and, if necessary, make final adjustments during system checkout. 8. For normally closed dampers, rotate the damper crank arm until the damper is closed. While holding the damper closed, tighten the nut on the ball joint connector on the damper crank arm. To ensure that the damper closes completely, make adjustments so that the actuator is 1/16" (1.6 mm) from the retracted end of stroke when the damper closes. Final adjustment of the actuator and damper must be performed when the system is powered and functioning. Refer to the CHECKOUT section to ensure that the damper is linked correctly. F-15070-13 Copyright 2006 TAC All Rights Reserved. 11 Valve For valve assembly details refer to AV-600, Valve Linkage Kit General Instructions, F-26279 or AV-601, Linkage Extension Kit General Instructions, F-26280. Refer to Figure-21 for external dimensions of the valve actuator. Adjustments Auxiliary Switch (MA-5xxx-500) The switching point is adjustable over the entire actuator stroke and is pre-set at the factory to close the N.C. contacts at the retracted end of stroke. Turning the switch adjustment screw CW (using TOOL-12), adjusts the make (or break) point closer to the extended end of stroke. (Refer to Figure-15). MA-52XX-500 Series Auxiliary Switch Adjustment Screw Position Indication and Switch Action Cam Figure-15 Auxiliary Switch Actuation Point Adjustment and Position Indication for MA-5xxx-500 Series. CHECKOUT After the entire system has been installed and the actuator has been powered up, perform the following checks for proper system operation. Caution: Never power the actuator without a spring return linkage attached. Positioning with If the sensed media is within the controller’s setpoint range, the actuator can be positioned by adjusting the controller setpoint up and down. Check for correct operation of the actuator Controller (valve or damper) while the actuator is being stroked. Go, No-Go Test 1. Apply power to the actuator. The actuator motor should run and the actuator shaft should extend. 2. Remove power from the actuator. The actuator motor should stop running and the actuator shaft should spring-return to the retracted position. 12 Copyright 2006 TAC All Rights Reserved. F-15070-13 THEORY OF OPERATION Refer to Figure-16. The permanently sealed, oil-filled case contains a movable hydraulic piston assembly and an electric pump for the hydraulic system. The pump generates a fluid pressure which is transmitted to the top of the piston, creating a hydraulic force which drives the piston downward. Opposing the hydraulic force is the spring of the valve or damper linkage. When the hydraulic force becomes great enough to overcome the opposing spring force, the piston translates downward, extending the output shaft. The electric pump is powered by the input supply voltage and runs whenever the voltage is applied. When power is removed from the pump, it stops running, decreasing the hydraulic force above the piston. This allows the spring force to overcome the hydraulic force, pushing the piston upward and retracting the output shaft. The oil above the piston is allowed to flow backward through the pump by means of a check valve. Hydraulic Oil-Filled Case Piston Assembly Check Valve Electric Pump Switch/Thermostat To AC Power Source Position Indication and Switch Action Cam Auxiliary Orange Switch Switch Point Adjustment Brown for Auxiliary Switch Red/White Auxiliary Switch Wires Figure-16 MA-5xxx Series Actuators. REPLACEMENT PARTS The installation of replacement actuators, in place of the obsolete series of MA-5xxx actuators (refer to Figure-17), may require additional items. These replacement items are required for the following reasons: 1. The AM-601 damper linkage is used to convert base actuators to damper actuators when damper models are not available. 2. The AM-602 spacer is used when current actuators are installed on old linkages (refer to Figure-18 and Figure-19). 3. The AE-249 transformer (208 Vac to 120 Vac) is used when replacing 208 Vac actuators (MA-5xx2) with 120 Vac actuators (MA-5xx0). 3/4" 1-5/16" 1-5/16" (19 mm) (33 mm) (33 mm) MA-521X-XXX MA-521X-XXX-2 MA-521X-XXX-3 Obsolete Actuators Current Actuator Figure-17 Current and Obsolete Actuators. F-15070-13 Copyright 2006 TAC All Rights Reserved. 13 2-3/16" (56mm approx.) 1-5/8" (41mm approx.) 1-5/8" (41mm approx.) Obsolete Linkages Current Linkage Spacer AV-315, AV-317, AV-319-10, AV-600 AM-602 & AV-319-20 Figure-18 Current and Obsolete Valve Linkages. No Strap Strap Obsolete AM-601 Current AM-601-0-0-2 Figure-19 Current and Obsolete Damper Linkages. MAINTENANCE The actuator is sealed in oil and requires no maintenance. Regular maintenance of the total system is recommended to assure sustained, optimum performance. TROUBLESHOOTING Use the following steps to locate malfunctions: 1. Check the actuator by applying the proper supply voltage. 2. The motor should run when power is applied. If it does not run, the actuator is inoperative and should be replaced. 3. While the motor is running, the actuator should extend. If it does not extend, check the mechanical linkage for any damage or misadjustment which could prevent the actuator from extending. If the mechanical linkage is inoperative, adjust the linkage or replace the damaged components, as applicable. If the mechanical linkage moves correctly and freely, the problem lies in the actuator and it must be replaced. 4. If applying power directly to the actuator results in correct operation of the actuator, the actuator and linkage are functional, and the problem lies in the wiring or thermostat. Repair or replace the wiring or thermostat, as applicable. FIELD REPAIR None. Replace an inoperative actuator with a functional unit. 14 Copyright 2006 TAC All Rights Reserved. F-15070-13 DIMENSIONAL DATA (4) 1/4" 5/16" 4-5/8" (6 mm) (8 mm) (117 mm) 4-3/4" (120 mm) 4-1/4" 3-1/4" Actuator (83 mm) (108 mm) 4-1/4" 5-3/4" (110 mm) (146 mm) 8" 2" 5-1/2" (203 mm) (50 mm) (140 mm) Figure-20 Damper Linkage Assembly Dimensions. 3-1/4" Dia. 3-23/32" (83 mm) (94 mm) 6-3/4" (171 mm) 1-3/8" (35 mm) 2-9/32" (58 mm) Figure-21 Actuator Dimensions. F-15070-13 Copyright 2006 TAC All Rights Reserved. 15 Copyright 2006, TAC TAC All brand names, trademarks and registered 1354 Clifford Avenue trademarks are the property of their respective P.O. Box 2940 owners. Information contained within this Loves Park, IL 61132-2940 document is subject to change without notice. F-15070-13 www.tac.com
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the MA-5200 have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
Manufacturers







What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods