Elite.Parts chervon right Manufacturers chervon right R chervon right ROSEMOUNT chervon right 3051TG3A2A21AB4
About product Datasheet FAQ

ROSEMOUNT 3051TG3A2A21AB4

Description

TRANSMITTER

Part Number

3051TG3A2A21AB4

Price

Request Quote

Manufacturer

ROSEMOUNT

Lead Time

Request Quote

Category

PRODUCTS - 3

Datasheet

pdf file

3051TG3A2A21AB4-datasheet-5797319751.pdf

3318 KiB

Extracted Text

Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Rosemount 3051 Pressure Transmitter THE PROVEN INDUSTRY LEADER IN PRESSURE MEASUREMENT Best-in-Class performance with 0.04% High Accuracy option Industry first installed five-year stability Unmatched Dynamic Performance ™ Coplanar platform enables integrated pressure, flow, and level solutions ® Advanced PlantWeb Functionality to increase plant productivity Contents Product Offering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4 Product Certifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 12 HART Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 12 Fieldbus Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 15 Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 17 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 25 HART Protocol C1 Option Configuration Data Sheet . . . . . . . . . . . . . . . . . . . . . . .page 41 www.rosemount.com Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Setting the Standard for Pressure Measurement Industry’s best total performance, a flexible Coplanar platform, and installed five-year stability, has made the Rosemount 3051 the standard in pressure measurement. Industry’s best-in-class total performance Coplanar platform enables complete point of ±0.15% solutions Total performance is the true measure of “real-world” The versatile Coplanar platform design enables the transmitter performance. Using superior sensor best process connection for pressure, flow and level technology and engineered for optimal performance, applications. Right out of the box, the solution arrives the 3051 delivers unprecedented ±0.04% reference factory calibrated, pressure-tested, and ready to accuracy, resulting in total operating performance of install. Only the 3051 has a flexible design to reduce ±0.15%. Superior total performance equates to engineering and inventory costs. reduced variability and improved plant safety. Advanced PlantWeb Functionality Installed five-year stability of ±0.125% The 3051 powers the PlantWeb Transmitter stability is a critical measure of architecture by delivering the best transmitter performance over time. Through sensor and transmitter, best installation aggressive simulation testing beyond standard IEC practices, and best in class field 770 testing, the 3051 has proven its ability to intelligence. One component is the maintain performance over a five year period under enhanced diagnostic capabilities in the most demanding process conditions. Superior FOUNDATION fieldbus that provide an increase in transmitter stability reduces calibration frequency to process visibility, enabling proactive maintenance, save operation and maintenance costs. improving process availability and plant productivity. Unmatched dynamic performance In dynamic applications, speed of measurement is as important as repeatability. The 3051 responds up to eight times faster than the typical pressure transmitter to detect and control variations quickly and efficiently. Superior dynamic response yields more accurate measurements to reduce variability and increase profitability. Rosemount Pressure Solutions ® Rosemount 3051S Series of Instrumentation Annubar Flowmeter Series: Rosemount 3051SFA, Scalable pressure, flow and level measurement solutions improve 3095MFA, and 485 installation and maintenance practices. The state-of-the-art, fifth generation Rosemount 485 Annubar combined with the 3051S or 3095MV MultiVariable transmitter Rosemount 3095MV Mass Flow Transmitter creates an accurate, repeatable and dependable insertion-type Accurately measures differential pressure, static pressure and flowmeter. process temperature to dynamically calculate fully compensated mass flow. Compact Orifice Flowmeter Series: Rosemount 3051SFC, 3095MFC, and 405 Rosemount 305 and 306 Integral Manifolds Factory-assembled, calibrated and seal-tested manifolds reduce Compact Orifice Flowmeters can be installed between existing on-site installation costs. flanges, up to a Class 600 (PN100) rating. In tight fit applications, a conditioning orifice plate version is available, requiring only two Rosemount 1199 Diaphragm Seals diameters of straight run upstream. Provides reliable, remote measurements of process pressure and ® protects the transmitter from hot, corrosive, or viscous fluids. ProPlate Flowmeter Series: Rosemount ProPlate, Mass ProPlate, and 1195 Orifice Plate Primary Element Systems: Rosemount These integral orifice flowmeters eliminate the inaccuracies that 1495 and 1595 Orifice Plates, 1496 Flange Unions and become more pronounced in small orifice line installations. The 1497 Meter Sections completely assembled, ready to install flowmeters reduce cost and A comprehensive offering of orifice plates, flange unions and simplify installation. meter sections that is easy to specify and order. The 1595 Conditioning Orifice provides superior performance in tight fit applications. 2 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Product Offering Rosemount 3051C Differential, Gage, and Absolute See ordering information on page 25. Performance up to 0.04% accuracy Installed five-year stability of 0.125% Coplanar platform enables integrated manifold, primary element and diaphragm seal solutions Calibrated spans/ranges from 0.1 inH O to 4000 psi 2 (0,25 mbar to 276 bar) ® ® 316L SST, Hastelloy C276, Monel , Tantalum, Gold-plated Monel, or Gold-plated 316L SST process isolators Rosemount 3051T Gage and Absolute See ordering information on page 29. Performance up to 0.04% accuracy Installed five-year stability of 0.125% Calibrated spans from 0.3 to 10000 psi (10,3 mbar to 689 bar) Multiple process connections available 316L SST and Hastelloy C276 process isolators Rosemount 3051L Liquid Level See ordering information on page 31. Performance up to 0.075% accuracy Welded fill fluid system provides best-in-class system reliability Flush and extended diaphragms Multiple fill fluids and wetted materials available 3 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Specifications PERFORMANCE SPECIFICATIONS Total Performance is based on combined errors of reference accuracy, ambient temperature effect, and static pressure effect. This product data sheet covers both HART and fieldbus protocols unless specified. Conformance To Specification (±3σ (Sigma)) Technology leadership, advanced manufacturing techniques and statistical process control ensure specification conformance to at least ±3σ. (1) Reference Accuracy Models Standard High Accuracy Option 3051CD, 3051CG Range 0 (CD) ±0.10% of span For spans less than 2:1, accuracy = ±0.05% of URL Range 1 ±0.10% of span For spans less than 15:1, accuracy = URL ⎛⎞ ± 0.025 + 0.005 --------------- % of Span ⎝⎠ Span Ranges 2-5 ±0.065% of span Ranges 2-4 For spans less than 10:1, accuracy = High Accuracy Option, P8 ±0.04% of span URL ⎛⎞ ± 0.015 + 0.005 --------------- % of Span For spans less than 5:1, accuracy = ⎝⎠ Span URL ⎛⎞ ± 0.015 + 0.005 --------------- % of Span ⎝⎠ Span 3051T Ranges 1-4 ±0.065% of span Ranges 2-4 For spans less than 10:1, accuracy = High Accuracy Option, P8 ±0.04% of span URL ⎛⎞ ± 0.0075 --------------- % of Span For spans less than 5:1, accuracy = ⎝⎠ Span URL ⎛⎞ ± 0.0075 --------------- % of Span ⎝⎠ Span Range 5 ±0.075% of span For spans less than 10:1, accuracy = URL ⎛⎞ ± 0.0075 --------------- % of Span ⎝⎠ Span 3051CA Ranges 1-4 ±0.065% of span Ranges 2-4 For spans less than 10:1, accuracy = High Accuracy Option, P8 ±0.04% of span URL ⎛⎞ ± 0.0075 --------------- % of Span For spans less than 5:1, accuracy = ⎝⎠ Span URL ⎛⎞ ± 0.0075 --------------- % of Span ⎝⎠ Span 3051H/3051L All Ranges ±0.075% of span For spans less than 10:1, accuracy = URL ⎛⎞ ± 0.025 + 0.005 % of Span --------------- ⎝⎠ Span (1) For FOUNDATION fieldbus transmitters, use calibrated range in place of span. For zero based spans, reference conditions, silicone oil fill, SST materials, 1 /2 in. - 18 NPT (3051T) process connections, digital trim values set to equal range points. Coplanar flange (3051C) or 4 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Total Performance For ±50 °F (28 °C) temperature changes, up to 1000 psi (6,9 MPa) line pressure (CD only), from 1:1 to 5:1 rangedown. Models Total Performance 3051C Ranges 2-5 ±0.15% of span 3051T Ranges 1-4 ±0.15% of span Long Term Stability Models Long Term Stability 3051C Ranges 2-5 ±0.125% of URL for 5 years ±50 °F (28 °C) temperature changes, and up to 1000 psi (6,9 MPa) line pressure. 3051CD Low/Draft Range Ranges 0-1 ±0.2% of URL for 1 year 3051T Ranges 1-4 ±0.125% of URL for 5 years ±50 °F (28 °C) temperature changes, and up to 1000 psi (6,9 MPa) line pressure. Rosemount 3051H Ranges 2-3 ±0.1% of URL for 1 year Ranges 4-5 ±0.2% of URL for 1 year Dynamic Performance 4 - 20 mA Fieldbus (1) (3) (HART protocol) protocol Typical HART Transmitter Response Time (2) Total Response Time (T + T ) : d c 3051C, Ranges 2-5: 100 ms 152 ms Range 1: 255 ms 307 ms Range 0: 700 ms 752 ms Transmitter Output vs. Time 3051T: 100 ms 152 ms Pressure Released 3051H/L: Consult factory Consult factory T = Dead Time d Dead Time (Td) 45 ms (nominal) 97 ms T T d c T = Time Constant c 100% Update Rate 22 times per second 22 times per second Response Time = T +T d c (1) Dead time and update rate apply to all models and ranges; analog output only 63.2% of Total (2) Nominal total response time at 75 °F (24 °C) reference conditions. 36.8% Step Change (3) Transmitter fieldbus output only, segment macro-cycle not included. 0% Time Line Pressure Effect per 1000 psi (6,9 MPa) For line pressures above 2000 psi (13,7 MPa) and Ranges 4-5, see user manual (Rosemount publication number 00809-0100-4001). Models Line Pressure Effect (1) 3051CD Zero Error ±0.125% of URL/100 psi (6,89 bar) Range 0 Range 1 ±0.25% of URL/1000 psi (68,9 bar) Ranges 2-3 ±0.05% of URL/1000 psi (68,9 bar) for line pressures from 0 to 2000 psi (0 to 13,7 MPa) Span Error Range 0 ±0.15% of reading/100 psi (6,89 bar) Range 1 ±0.4% of reading/1000 psi (68,9 bar) Ranges 2-3 ±0.1% of reading/1000 psi (68,9 bar) (1) 3051HD Zero Error ±0.1% of URL/1000 psi (68,9 bar) for line pressures from 0 to 2000 psi (0 to 13,7 MPa) All Ranges Span Error All Ranges ±0.1% of reading/1000 psi (68,9 bar) (1) Can be calibrated out at line pressure. 5 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Ambient Temperature Effect per 50°F (28°C) Models Ambient Temperature Effect 3051CD/CG Range 0 ±(0.25% URL + 0.05% span) Range 1 ±(0.1% URL + 0.25% span) Ranges 2-5 ±(0.0125% URL + 0.0625% span) from 1:1 to 5:1 ±(0.025% URL + 0.125% span) from 5:1 to 100:1 3051T Range 1 ±(0.025% URL + 0.125% span) from 1:1 to 10:1 ±(0.05% URL + 0.125% span) from 10:1 to 100:1 Range 2-4 ±(0.025% URL + 0.125% span) from 1:1 to 30:1 ±(0.035% URL + 0.125% span) from 30:1 to 100:1 Range 5 ±(0.1% URL + 0.15% span) 3051CA All Ranges ±(0.025% URL + 0.125% span) from 1:1 to 30:1 ±(0.035% URL + 0.125% span) from 30:1 to 100:1 3051H All Ranges ±(0.025% URL + 0.125% span + 0.35 inH O) from 1:1 to 30:1 2 ±(0.035% URL + 0.125% span + 0.35 inH O) from 1:1 to 30:1 2 ® 3051L See Rosemount Inc. Instrument Toolkit software. Mounting Position Effects Models Mounting Position Effects 3051C Zero shifts up to ±1.25 inH O (3,11 mbar), which can be calibrated out. No span effect. 2 3051H Zero shifts up to ±5 inH O (12,43 mbar), which can be calibrated out. No span effect. 2 3051L With liquid level diaphragm in vertical plane, zero shift of up to 1 inH O (2,49 mbar). With diaphragm in 2 horizontal plane, zero shift of up to 5 inH O (12,43 mbar) plus extension length on extended units. All zero 2 shifts can be calibrated out. No span effect. 3051T/CA Zero shifts up to 2.5 inH O (6,22 mbar), which can be calibrated out. No span effect. 2 Vibration Effect Transient Protection (Option Code T1) All Models: All Models Meets IEEE C62.41, Category B Measurement effect due to vibrations is negligible except at 6 kV crest (0.5 μs - 100 kHz) resonance frequencies. When at resonance frequencies, vibration 3 kV crest (8 × 20 microseconds) effect is less than ±0.1% of URL per g when tested between 15 6 kV crest (1.2 × 50 microseconds) and 2000 Hz in any axis relative to pipe-mounted process Meets IEEE C37.90.1, Surge Withstand Capability conditions. SWC 2.5 kV crest, 1.25 MHz wave form General Specifications: Power Supply Effect Response Time: < 1 nanosecond All Models Peak Surge Current: 5000 amps to housing Peak Transient Voltage: 100 V dc Less than ±0.005% of calibrated span per volt. Loop Impedance: < 25 ohms Applicable Standards: IEC61000-4-4, RFI Effects IEC61000-4-5 All Models NOTE: ±0.1% of span from 20 to 1000 MHz and for field strength up to 30 Calibrations at 68 °F (20 °C) per ASME Z210.1 (ANSI) V/m. 6 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 FUNCTIONAL SPECIFICATIONS Range and Sensor Limits TABLE 1. 3051CD, 3051CG, 3051L, and 3051H Range and Sensor Limits Minimum Span Range and Sensor Limits Lower (LRL) (1) 3051CD , Upper 3051C 3051C/ 3051L 3051L 3051H 3051H CG, L, H (URL) Differential Gage Differential Gage Differential Gage 0 0.1 inH O 3.0 inH O –3.0 inH O NA NA NA NA NA 2 2 2 (0,25 mbar) (7,47 mbar) (-7,47 mbar) 1 0.5 inH O 25 inH O –25 inH O –25 inH O NA NA NA NA 2 2 2 2 (1,2 mbar) (62,3 mbar) (–62,1 mbar) (–62,1 mbar) 2 2.5 inH O 250 inH O –250 inH O –250 inH O –250 inH O –250 inH O –250 inH O –250 inH O 2 2 2 2 2 2 2 2 (6,2 mbar) (0,62 bar) (–0,62 bar) (–0,62 bar) (–0,62 bar) (–0,62 bar) (–0,62 bar) (–0,62 bar) 3 10 inH O 1000 inH O –1000 inH O 0.5 psia –1000 inH O 0.5 psia –1000 inH O 0.5 psia 2 2 2 2 2 (24,9 mbar) (2,49 bar) (–2,49 bar) (34,5 mbar abs) (–2,49 bar) (34,5 mbar abs) (–2,49 bar) (34,5 mbar abs) 4 3 psi 300 psi –300 psi 0.5 psia –300 psi 0.5 psia –300 psi 0.5 psia (0,20 bar) (20,6 bar) (–20,6 bar) (34,5 mbar abs) (–20,6 bar) (34,5 mbar abs) (–20,6 bar) (34,5 mbar abs) 5 20 psi 2000 psi – 2000 psi 0.5 psia NA NA – 2000 psi 0.5 psia (1,38 bar) (137,9 bar) (–137,9 bar) (34,5 mbar abs) (–137,9 bar) (34,5 mbar abs) (1) Range 0 only available with 3051CD. Range 1 only available with 3051CD or 3051CG. TABLE 2. Range and Sensor Limits 3051CA 3051T Range and Sensor Limits Range and Sensor Limits (1) Minimum Upper Lower Minimum Upper Lower Lower Span (URL) (LRL) Span (URL) (LRL) (LRL) (Gage) 1 0.3 psia 30 psia 0 psia 1 0.3 psi 30 psi 0 psia –14.7 psig (20,6 mbar) (2,07 bar) (0 bar) (20,6 mbar) (2,07 bar) (0 bar) (–1,01 bar) 2 1.5 psia 150 psia 0 psia 2 1.5 psi 150 psi 0 psia –14.7 psig (0,103 bar) (10,3 bar) (0 bar) (0,103 bar) (10,3 bar) (0 bar) (–1,01 bar) 3 8 psia 800 psia 0 psia 3 8 psi 800 psi 0 psia –14.7 psig (0,55 bar) (55,2 bar) (0 bar) (0,55 bar) (55,2 bar) (0 bar) (–1,01 bar) 4 40 psia 4000 psia 0 psia 4 40 psi 4000 psi 0 psia –14.7 psig (2,76 bar) (275,8 bar) (0 bar) (2,76 bar) (275,8 bar) (0 bar) (–1,01 bar) 5 2000 psi 10000 psi 0 psia –14.7 psig (137,9 bar) (689,4 bar) (0 bar) (–1,01 bar) (1) Assumes atmospheric pressure of 14.7 psig. 7 Range Range Range Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Zero and Span Adjustment Requirements FOUNDATION fieldbus Parameters (HART and Low Power) Schedule Entries 7 (max.) Links 20 (max.) Zero and span values can be set anywhere within the range limits stated in Table 1 and Table 2. Virtual Communications Relationships (VCR) 12 (max.) Span must be greater than or equal to the minimum span stated in Standard Function Blocks Table 1 and Table 2. Resource Block Service Contains hardware, electronics, and diagnostic information. Liquid, gas, and vapor applications Transducer Block Contains actual sensor measurement data including the sensor 4–20 mA (Output Code A) diagnostics and the ability to trim the pressure sensor or recall Output factory defaults. Two-wire 4–20 mA, user-selectable for linear or square root LCD Block output. Digital process variable superimposed on 4–20 mA Configures the local display. signal, available to any host that conforms to the HART protocol. 2 Analog Input Blocks Power Supply Processes the measurements for input into other function External power supply required. Standard transmitter (4–20 mA) blocks. The output value is in engineering units or custom and operates on 10.5 to 55 V dc with no load. contains a status indicating measurement quality. Load Limitations PID Block Maximum loop resistance is determined by the voltage level of Contains all logic to perform PID control in the field including the external power supply, as described by: cascade and feedforward. Max. Loop Resistance = 43.5 (Power Supply Voltage – 10.5) Backup Link Active Scheduler (LAS) The transmitter can function as a Link Active Scheduler if the current link master device fails or is removed from the segment. Advanced Control Function Block Suite (Option Code A01) Input Selector Block Selects between inputs and generates an output using specific Operating selection strategies such as minimum, maximum, midpoint, Region average or first “good.” Arithmetic Block Provides pre-defined application-based equations including flow Voltage (V dc) with partial density compensation, electronic remote seals, hydrostatic tank gauging, ratio control and others. Communication requires a minimum loop resistance of 250 ohms. Signal Characterizer Block Characterizes or approximates any function that defines an (1) For CSA approval, power supply must not exceed 42.4 V. input/output relationship by configuring up to twenty X, Y coordinates. The block interpolates an output value for a given FOUNDATION fieldbus (output code F) and input value using the curve defined by the configured Profibus (output code W) coordinates. Power Supply Integrator Block External power supply required; transmitters operate on 9.0 to Compares the integrated or accumulated value from one or two 32.0 V dc transmitter terminal voltage. variables to pre-trip and trip limits and generates discrete output signals when the limits are reached. This block is useful for Current Draw calculating total flow, total mass, or volume over time. 17.5 mA for all configurations (including LCD display option) FOUNDATION fieldbus Function Block Execution Times FOUNDATION fieldbus Diagnostics Suite (Option Code D01) Block Execution Time The 3051C FOUNDATION fieldbus Diagnostics provide Abnormal Resource - Situation Prevention (ASP) indictation. The integral statistical Transducer - process monitoring (SPM) technology calculates the mean and standard deviation of the process variable 22 times per second. LCD Block - The 3051C ASP algorithm uses these values and highly flexible Analog Input 1, 2 30 milliseconds configuration options for customization to many user-defined or PID 45 milliseconds application specific abnormal situations. The detection of Input Selector 30 milliseconds plugged impulse lines is the first available predefined Arithmetic 35 milliseconds application. Signal Characterizer 40 milliseconds Integrator 35 milliseconds 8 Load (Ohms) Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Static Pressure Limit Low Power (Output Code M) Rosemount 3051CD Only Output Operates within specifications between static line pressures of 0.5 psia and 3626 psig (4500 psig (310, 3 bar) for Three wire 1–5 V dc or 0.8–3.2 V dc (Option Code C2) Option Code P9). user-selectable output. Also user selectable for linear or square root output configuration. Digital process variable superimposed Range 0: 0.5 psia and 750 psig (3, 4 bar and 51, 7 bar) on voltage signal, available to any host conforming to the HART Range 1: 0.5 psia and 2000 psig (3, 4 bar and 137, 9 bar) protocol. Low-power transmitter operates on 6–12 V dc with no load. Burst Pressure Limits Burst pressure on Coplanar, traditional, or 3051H process flange is Power Consumption 10000 psig (69 MPa). 3.0 mA, 18–36 mW Burst pressure for the 3051T is Ranges 1–4: 11000 psi (75,8 MPa) Minimum Load Impedance Range 5: 26000 psig (179 MPa) 100 kΩ (V wiring) out Failure Mode Alarm Indication Output Code A Optional 5-digit LCD display If self-diagnostics detect a gross transmitter failure, the analog signal will be driven either below 3.75 mA or to 21.75 mA to alert Overpressure Limits the user. NAMUR-compliant values are available, option code Rosemount 3051CD/CG C4. High or low alarm signal is user-selectable by internal • Range 0: 750 psi (51,7 bar) jumper. • Range 1: 2000 psig (137,9 bar) Output Code M • Ranges 2–5: 3626 psig (250 bar) If self-diagnostics detect a gross transmitter failure, the analog 4500 psig (310,3 bar) for option code P9 signal will be driven either below 0.94 V or above 5.4 V to alert Rosemount 3051CA the user (below 0.75 V or above 4.4 V for Option C2). High or low alarm signal is user-selectable by internal jumper. • Range 1: 750 psia (51,7 bar) Output Code F and W • Range 2: 1500 psia (103,4 bar) If self-diagnostics detect a gross transmitter failure, that • Range 3: 1600 psia (110,3 bar) information gets passed as a status along with the process • Range 4: 6000 psia (413,7 bar) variable. Rosemount 3051H • All Ranges: 3626 psig (25 MPa) Temperature Limits Rosemount 3051TG/TA Ambient • Range 1: 750 psi (51,7 bar) –40 to 185 °F (–40 to 85 °C) (1) • Range 2: 1500 psi (103,4 bar) With LCD display : –4 to 175 °F (–20 to 80 °C) • Range 3: 1600 psi (110,3 bar) Storage • Range 4: 6000 psi (413,7 bar) –50 to 230 °F (–46 to 110 °C) • Range 5: 15000 psi (1034,2 bar) With LCD display: –40 to 185 °F (–40 to 85 °C) For 3051L or Level Flange Option Codes FA, FB, FC, FD, FP, and Process FQ, limit is 0 psia to the flange rating or sensor rating, whichever is At atmospheric pressures and above. See Table 4 lower. (1) LCD display may not be readable and LCD updates will be slower TABLE 3. 3051L and Level Flange Rating Limits at temperatures below -4 °F (-20 °C). Standard Type CS Rating SST Rating ANSI/ASME Class 150 285 psig 275 psig ANSI/ASME Class 300 740 psig 720 psig ANSI/ASME Class 600 1480 psig 1440 psig At 100 °F (38 °C), the rating decreases with increasing temperature. DIN PN 10–40 40 bar 40 bar DIN PN 10/16 16 bar 16 bar DIN PN 25/40 40 bar 40 bar At 248 °F (120 °C), the rating decreases with increasing temperature. 9 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 PHYSICAL SPECIFICATIONS TABLE 4. 3051 Process Temperature Limits Electrical Connections 3051CD, 3051CG, 3051CA 1 1 (1) /2–14 NPT, PG 13.5, G /2, and M20 × 1.5 (CM20) conduit. HART Silicone Fill Sensor interface connections fixed to terminal block. (2) with Coplanar Flange –40 to 250 °F (–40 to 121 °C) (2)(3) with Traditional Flange –40 to 300 °F (–40 to 149 °C) Process Connections (2) with Level Flange –40 to 300 °F (–40 to 149 °C) (2) All Models except 3051L and 3051T with 305 Integral Manifold –40 to 300 °F (–40 to 149 °C) 1 1 (1) (4)(5) /4–18 NPT on 2 /8-in. centers Inert Fill Sensor 0 to 185 °F (–18 to 85 °C) 1 1 1 /2–14 NPT on 2-, 2 /8-, or 2 /4-in. centers 3051H (Process Fill Fluid) ® (1) Rosemount 3051L D.C. Silicone 200 –40 to 375 °F (–40 to 191 °C) (1) Inert –50 to 350 °F (–45 to 177 °C) High pressure side: 2-, 3-, or 4-in., ASME B 16.5 (ANSI) Class ®(1) 150, 300 or 600 flange; 50, 80 or 100 mm, PN 40 or 10/16 flange Neobee M-20 0 to 375 °F (–18 to 191 °C) 1 1 3051T (Process Fill Fluid) Low pressure side: /4–18 NPT on flange /2–14 NPT on adapter (1) (2) Rosemount 3051T Silicone Fill Sensor –40 to 250 °F (–40 to 121 °C) (1) (2) 1 Inert Fill Sensor –22 to 250 °F (–30 to 121 °C) /2–14 NPT female. A DIN 16288 Male (available in SST for Range 1–4 transmitters only), or Autoclave type F-250-C 3051L Low-Side 9 1 (Pressure relieved /16–18 gland thread; /4 OD high pressure Temperature Limits (1) (2) tube 60° cone; available in SST for Range 5 transmitters only). Silicone Fill Sensor –40 to 250 °F (–40 to 121 °C) (1) (2) Inert Fill Sensor 0 to 185 °F (–18 to 85 °C) Process-Wetted Parts 3051L High-Side Temperature Limits (Process Fill Fluid) Drain/Vent Valves ® Syltherm XLT –100 to 300 °F (–73 to 149 °C) 316 SST, Hastelloy C276, or Monel material (Monel not ® D.C. Silicone 704 32 to 400 °F (0 to 205 °C) available with 3051L or 3051H) D.C. Silicone 200 –40 to 400 °F (–40 to 205 °C) Process Flanges and Adapters Inert –50 to 350 °F (–45 to 177 °C) Plated carbon steel, SST cast CF-8M (cast version of 316 SST, Glycerin and Water 0 to 200 °F (–18 to 93 °C) material per ASTM-A743), C-Type cast alloy CW12MW, or Neobee M-20 0 to 400 °F (–18 to 205 °C) Monel cast alloy M30C Propylene Glycol and Water 0 to 200 °F (–18 to 93 °C) Wetted O-rings (1) Process temperatures above 185 °F (85 °C) require derating the Glass-filled PTFE or Graphite-filled PTFE ambient limits by a 1.5:1 ratio (0.6:1 ratio for the 3051H). Process Isolating Diaphragms (2) 220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for pressures below 0.5 psia. (3) 3051CD0 process temperature limits are –40 to 212 °F (–45 to 100 °C) (4) 160 °F (71 °C) limit in vacuum service. Isolating Diaphragm Material (5) Not available for 3051CA. 316L SST • • • • Hastelloy C276 • • • • Humidity Limits Monel • • 0–100% relative humidity Tantalum • • Gold-plated Monel • • Turn-On Time Gold-plated SST • • Performance within specifications less than 2.0 seconds (10.0 s for Profibus protocol) after power is applied to the transmitter Volumetric Displacement 3 3 Less than 0.005 in (0,08 cm ) Damping Analog output response to a step input change is user-selectable from 0 to 36 seconds for one time constant. This software damping is in addition to sensor module response time. 10 3051CD/CG 3051T 3051CA 3051H Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Rosemount 3051L Process Wetted Parts Flanged Process Connection (Transmitter High Side) Process Diaphragms, Including Process Gasket Surface •316L SST, Hastelloy C276, or Tantalum Extension • CF-3M (Cast version of 316L SST, material per ASTM-A743), or Hastelloy C276. Fits schedule 40 and 80 pipe. Mounting Flange • Zinc-cobalt plated CS or SST Reference Process Connection (Transmitter Low Side) Isolating Diaphragms • 316L SST or Hastelloy C276 Reference Flange and Adapter • CF-8M (Cast version of 316 SST, material per ASTM-A743) Non-Wetted Parts Electronics Housing Low-copper aluminum or CF-3M (Cast version of 316L SST, material per ASTM-A743). NEMA 4X, IP 65, IP 66 Coplanar Sensor Module Housing CF-3M (Cast version of 316L SST, material per ASTM-A743) Bolts ASTM A449, Type 1 (zinc-cobalt plated carbon steel) ASTM F593G, Condition CW1 (Austenitic 316 SST) ASTM A193, Grade B7M (zinc plated alloy steel) Monel K-500 Sensor Module Fill Fluid Silicone oil (D.C. 200) or Fluorocarbon oil (Halocarbon or ® Fluorinert FC-43 for 3051T) Process Fill Fluid (3051L and 3051H only) 3051L: Syltherm XLT, D.C. Silicone 704, D.C. Silicone 200, inert, glycerin and water, Neobee M-20 or propylene glycol and water 3051H: inert, Neobee M-20, or D.C. Silicone 200 Paint Polyurethane Cover O-rings Buna-N Shipping Weights Refer to “Shipping Weights” on page 38 11 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Product Certifications Approved Manufacturing Locations HART PROTOCOL Rosemount Inc. — Chanhassen, Minnesota USA Emerson Process Management GmbH & Co. — Wessling, Hazardous Locations Certifications Germany Emerson Process Management Asia Pacific North American Certifications Private Limited — Singapore Beijing Rosemount Far East Instrument Co., LTD — Beijing, China FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. European Directive Information Dust-Ignition-Proof for Class II, Division 1, Groups E, F, and The EC declaration of conformity for all applicable European G. Dust-Ignition-Proof for Class III, Division 1. directives for this product can be found on the Rosemount website Factory Sealed, Enclosure Type 4X at www.rosemount.com. A hard copy may be obtained by contacting an Emerson Process Management representative. I5 Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, ATEX Directive (94/9/EC) Division 1 when connected per Rosemount drawing All 3051 transmitters comply with the ATEX Directive. 03031-1019; Non-incendive for Class I, Division 2, Groups A, B, C, and D. European Pressure Equipment Directive (PED) (97/23/EC) Temperature Code:T4 (Ta = 40 °C), T3 (Ta = 85 °C), 3051CA4; 3051CG2, 3, 4, 5; 3051CD2, 3, 4, 5 Enclosure Type 4X (also with P9 option); 3051HD2, 3, 4, 5; 3051HG2, 3, 4, 5; For input parameters see control drawing 03031-1019. 3051PD2, 3; and 3051PG2, 3, 4, 5 Pressure Transmitters — QS Certificate of Assessment - EC No. PED-H-100 Canadian Standards Association (CSA) Module H Conformity Assessment E6 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof for Class II and Class III, Division 1, All other 3051/3001 Pressure Transmitters Groups E, F, and G. Suitable for Class I, Division 2 Groups — Sound Engineering Practice A, B, C, and D for indoor and outdoor hazardous locations. Enclosure type 4X, factory sealed Transmitter Attachments: Diaphragm Seal - Process Flange - Manifold C6 Explosion-Proof and intrinsically safe approval. Intrinsically — Sound Engineering Practice safe for Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount drawings Electro Magnetic Compatibility (EMC) (2004/108/EC) 03031-1024. Temperature Code T3C. All 3051 Pressure Transmitters meet all of the requirements of Explosion-Proof for Class I, Division 1, Groups B, C, and D. EN61326: 1997 - A1, A2, and A3 and NAMUR NE-21 Dust-Ignition-Proof for Class II and Class III, Division 1, Groups E, F, and G. Suitable for Class I, Division 2 Groups A, B, C, and D hazardous locations. Enclosure type 4X, Ordinary Location Certification for Factory Mutual factory sealed As standard, the transmitter has been examined and tested to For input parameters see control drawing 03031-1024. determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). 12 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 European Certifications Japanese Certifications I1 ATEX Intrinsic Safety and Dust E4 TIIS Flame-Proof Certification No.: BAS 97ATEX1089X II 1 GD Ex d IIC T6 EEx ia IIC T4 (–60 ≤ T ≤ +70 °C) a Certificate Description Dust Rating: T80 °C (–20 ≤ T ≤ 40 °C) IP66 a C15850 3051C/D/1 4–20 mA HART 1180 — no display C15851 3051C/D/1 4–20 mA HART TABLE 5. Input Parameters — with display U = 30V i C15854 3051T/G/1 4–20 mA HART, SST, Silicon I = 200 mA i — no display P = 0.9W i C15855 3051T/G/1 4–20 mA HART, Hastelloy C276, C = 0.012 µF Silicon — no display i C15856 3051T/G/1 4–20 mA HART, SST, Silicon Special Conditions for Safe Use (X): — with display When the optional transient protection terminal block is C15857 3051T/G/1 4–20 mA HART, Hastelloy C276, installed, the apparatus is not capable of withstanding the Silicon — with display 500V insulation test required by Clause 6.4.12 of I4 TIIS Intrinsic Safety EN50020:1994. This must be taken into account when Ex ia IIC T4 installing the apparatus. Certificate Description N1 ATEX Type n and Dust Certification No.: BAS 00ATEX3105X II 3 GD C16406 3051CD/CG U = 55 Vdc max i EEx nL T5 (–40°C ≤ T ≤ 70 °C) Australian Certifications amb Dust rating: T80 °C (–20 ≤ T ≤ 40 °C) IP66 a I7 SAA Intrinsic Safety Certification No.: AUS Ex 1249X Special Conditions for Safe Use (X): Ex ia IIC T4 (T = 70 °C) amb When the optional transient protection terminal block is IP66 installed, the apparatus is not capable of withstanding a When connected per Rosemount drawing 03031-1026 500V r.m.s. test to case. This must be taken into account on TABLE 6. Input Parameters any installation in which it is used, for example by assuring U = 30V i that the supply to the apparatus is galvanically isolated. I = 200 mA i E8 ATEX Flame-Proof and Dust I = 160 mA (output code A with T1) i Certification No.: KEMA 00ATEX2013X II 1/2 GD P = 0.9W i EEx d IIC T6 (–50 ≤ T ≤ 65 °C) a C = 0.01 µF i Dust rating T90 °C, IP66 C = 0.042 µF (output code M) i 1180 L = 10 µH Vmax = 55 V dc i L = 1.05 mH (output code A with T1) i Special Conditions for Safe Use (X): L = 0.75 mH (output code M with T1) i This device contains a thin wall diaphragm. Installation, maintenance, and use shall take into account the Special Conditions for Safe Use (X): environmental conditions to which the diaphragm will be The apparatus may only be used with a passive current subjected. The manufacturer’s instructions for installation limited power source Intrinsic Safety application. The power and maintenance shall be followed in detail to assure safety source must be such that Po ≤ (Uo * Io) / 4. Modules using during its expected lifetime. transient protection in the terminal assembly (T1 transient protection models) the apparatus enclosure is to be electrically bonded to the protective earth. The conductor used for the connection shall be equivalent to a copper 2 conductor of 4 mm minimum cross-sectional area. 13 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 E7 SAA Explosion-Proof (Flame-Proof) Certification No.: AUS Ex 03.1347X Ex d IIC T6 (T = 40 °C) amb DIP A21 T6 (T = 40 °C) amb IP66 Special Conditions for Safe Use (X): It is a condition of safe use for transmitter enclosures having cable entry thread other than metric conduit thread that the equipment be utilized with an appropriate certified thread adaptor. N7 SAA Type n (Non-sparking) Certification No.: AUS Ex 1249X Ex n IIC T4 (T = 70 °C) amb IP66 Special Conditions for Safe Use (X): Where the equipment is installed such that there is an unused conduit entry, it must be sealed with a suitable blanking plug to maintain the IP66 degree of protection. Any blanking plug used with the equipment shall be of a type which requires the use of a tool to effect its removal. Voltage source shall not exceed 55V dc. Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinstalled using any other approval types. Permanently mark the approval label to distinguish it from unused approval types. K5 E5 and I5 combination KB K5 and C6 combination KD K5, C6, I1, and E8 combination K6 C6, I1, and E8 combination K8 E8 and I1 combination K7 E7, I7, and N7 combination 14 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications IA ATEX FISCO Intrinsic Safety North American Certifications Certification No.: BAS 98ATEX1355X II 1 G EEx ia IIC T4 (T = –60 to +60 °C) FM Approvals amb IP66 E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. 1180 Dust-Ignition-Proof for Class II, Division 1, Groups E, F, and TABLE 8. Input Parameters G. Dust-Ignition-Proof for Class III, Division 1. U = 17.5 V i I5 Intrinsically Safe for use in Class I, Division 1, Groups A, B, I = 380 mA i C, and D; Class II, Division 1, Groups E, F, and G; Class III, P = 5.32 W i Division 1 when connected per Rosemount drawing C = ≤ 5 µF i 03031-1019; Non-incendive for Class I, Division 2, Groups L = ≤ 10 µH A, B, C, and D. i Temperature Code:T4 (Ta = 60 °C), T3 (Ta = 85 °C), Special Conditions for Safe Use (X): Enclosure Type 4X The device is not capable of withstanding the 500V For input parameters see control drawing 03031-1019. insulation test required by Clause 6.4.12 of EN50020:1994. This must be taken into account when installing the Canadian Standards Association (CSA) apparatus. E6 Explosion-Proof for Class I, Division 1, Groups B, C, and D. N1 ATEX Type n and Dust Dust-Ignition-Proof for Class II and Class III, Division 1, Certification No.: BAS 98ATEX3356X II 3 GD Groups E, F, and G. Suitable for Class I, Division 2 Groups U = 40 Vdc max i A, B, C, and D for indoor and outdoor hazardous locations. EEx nL IIC T5 (T = –40°C to 70 °C) a Enclosure type 4X, factory sealed Dust rating: T80 °C (T = –20 to 40 °C) IP66 amb Special Conditions for Safe Use (X): C6 Explosion-Proof and intrinsically safe approval. Intrinsically The device is not capable of withstanding the 500V safe for Class I, Division 1, Groups A, B, C, and D when insulation test required by Clause 6.4.12 of EN50020:1994. connected in accordance with Rosemount drawings This must be taken into account when installing the 03031-1024. Temperature Code T3C. apparatus. Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof for Class II and Class III, Division 1, E8 ATEX Flame-Proof and Dust Groups E, F, and G. Suitable for Class I, Division 2 Groups Certification No.: KEMA 00ATEX2013X II 1/2 GD A, B, C, and D hazardous locations. Enclosure type 4X, EEx d IIC T6 (T = –50 to 65 °C) amb factory sealed Dust rating T90 °C, IP66 For input parameters see control drawing 03031-1024. 1180 Vmax = 55 V dc European Certifications I1 ATEX Intrinsic Safety and Dust Special Conditions for Safe Use (X): Certification No.: BAS 98ATEX1355X II 1 GD This device contains a thin wall diaphragm. Installation, EEx ia IIC T4 (T = –60 to +60 °C) maintenance, and use shall take into account the amb Dust Rating: T70 °C (T –20 to 40 °C) IP66 environmental conditions to which the diaphragm will be amb 1180 subjected. The manufacturer’s instructions for installation and maintenance shall be followed in detail to assure safety TABLE 7. Input Parameters during its expected lifetime. U = 30V i I = 300 mA i P = 1.3 W i C = 0 µF i Special Conditions for Safe Use (X): The device is not capable of withstanding the 500V insulation test required by Clause 6.4.12 of EN50020:1994. This must be taken into account when installing the apparatus. 15 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 E7 SAA Explosion-Proof (Flame-Proof) Japanese Certifications Certification No.: AUS Ex 1347X E4 TIIS Flame-Proof Ex d IIC T6 (T = 40 °C) amb Ex d IIC T6 DIP A21 T6 (T = 40 °C) amb Certificate Description IP66 C15852 3051C/D/1 FOUNDATION Fieldbus Special Conditions for Safe Use (X): — no display It is a condition of safe use for transmitter enclosures having C15853 3051C/D/1 FOUNDATION Fieldbus cable entry thread other than metric conduit thread that the — with display equipment be utilized with an appropriate certified thread C15858 3051T/G/1 FOUNDATION Fieldbus, SST, Silicon adaptor. — no display C15859 3051T/G/1 FOUNDATION Fieldbus, Hastelloy N7 SAA Type n (Non-sparking) C276, Silicon — no display Certification No.: AUS Ex 1249X C15860 3051T/G/1 FOUNDATION Fieldbus, SST, Silicon Ex n IIC T4 (T = 70 °C) amb — with display IP66 C15861 3051T/G/1 FOUNDATION Fieldbus, Hastelloy C276, Silicon — with display Special Conditions for Safe Use (X): Where the equipment is installed such that there is an unused conduit entry, it must be sealed with a suitable Australian Certifications blanking plug to maintain the IP40 degree of protection. Any I7 SAA Intrinsic Safety blanking plug used with the equipment shall be of a type Certification No.: AUS Ex 1249X which requires the use of a tool to effect its removal. Voltage Ex ia IIC T4 (T = 60 °C) amb source shall not exceed 35V dc. IP66 When connected per Rosemount drawing 03031-1026. Combinations of Certifications TABLE 9. Input Parameters Stainless steel certification tag is provided when optional approval U = 30 V is specified. Once a device labeled with multiple approval types is i installed, it should not be reinstalled using any other approval I = 300 mA i types. Permanently mark the approval label to distinguish it from P = 1.3 W i unused approval types. C = 0 µF i L = 0 µH i K5 E5 and I5 combination KB K5 and C6 combination Special Conditions for Safe Use (X): KD K5, C6, I1, and E8 combination The apparatus may only be used with a passive current limited power source Intrinsic Safety application. The power K6 C6, I1, and E8 combination source must be such that Po ≤ (Uo * Io) / 4. Modules using K8 E8 and I1 combination transient protection in the terminal assembly (T1 transient K7 E7, I7, and N7 combination protection models) the apparatus enclosure is to be electrically bonded to the protective earth. The conductor used for the connection shall be equivalent to a copper conductor of 4 mm2 minimum cross-sectional area. 16 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Dimensional Drawings 3051 Exploded View Certification Label (1) Span and Zero Adjustments (Standard) Electronics Housing Terminal Block Cover O-ring Cover Electronics Board Nameplate Sensor Module Housing Rotation Set Screw (180° Maximum Housing Rotation without Further Disassembly) Coplanar Flange Process O-Ring Drain/Vent Valve Flange Adapter O-Ring Flange Alignment Screw (Not Pressure Retaining) Flange Adapters Flange Bolts 1) Span and Zero Adjustments are not available with fieldbus or profibus protocols. 17 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 3051C Coplanar Flange Dimensional Drawing (Differential Pressure Transmitter Shown) 1 1 5.0 (127) //2 2–14 NPT –14 NPT Certification Certification Conduit Connect Conduit ion Label Label 4.1 4.1 4.3 (110) (Two Places, Ot Connecther ion (105) (105) 0.75 (20) Clearance (Two Places, Ot Sizes Available) her 0.75 (20) Clearance for Cover Removal for Cover Removal Terminal Transmitter Connections Circuitry 7.1 (181) 7.1 (181 Nameplate 8.2 (209) Drain/Vent Valve Housing Rot Housing Rota at ti ion on Set Screw Set Screw Coplanar Flange Process Connection Per IEC 61518 2.126 (54) ±0.012 in. ¼–18 NPT on ¼–18 NPT on Coplanar Coplanar Flange Flange Connection Centers for for Pressure Connect Pressure Connection without the Use ion without the Use 6.4 (163) of Flange Adapters of Flange Adapters 1 /2–14 NPT on Optional Flange Adapters. Adapters can be rotated to give connection centers of 2.00 (51), 2.126 (54), or 2.25 (57). Coplanar Flange Mounting Configurations with Optional Bracket (B4) for 2-in. Pipe or Panel Mounting 2.8 4.3 5 1 (72) (110) /16 � 1 /2 Bolts for Panel Mounting 2.8 (71) (Not Supplied) 7.1 (181) 3 1 /8–16 × 1 /4 Bolts for Mounting to Transmitter 6.2 1.1 (28) (156) 2.8 (71) 3.4 (85) 4.8 (120) 2-inch U-Bolt for Pipe Mounting 3.3 (83) 6.0 (152) Dimensions are in inches (millimeters) 18 PIPE MOUNTING PANEL MOUNTING Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Traditional Flange Mounting Configurations with Optional Brackets for 2-in. Pipe or Panel Mounting Traditional Flange Panel Mounting Bracket (option B2/B8) Traditional Flange 2-in. Pipe Mounting Bracket (option B1/B7/BA) 10.1 (257) 4.2 (106) Impulse Piping 2.7 (67) 1.1 (28) 3.8 (95) 5 7 /16 x /8 Bolts for Panel 9.6 Mounting (Not Supplied) (243) 2.7 (67) 6.2 (158) 2.81(71) 1.4 (33) PANEL MOUNTING PIPE MOUNTING BRACKET 4.6 (116) BRACKET Traditional Flange (Options H2–H7) Dimensional Drawing 5.0 1 /2–14 NPT (127) Conduit Connection Certification 4.3 4.1 (Two Places Label (110) (105) Other Sizes Available) 0.75 (20) Clearance for Cover Removal Housing Transmitter Terminal Rotation Circuitry Connections Set Screw 7.9 (202) Nameplate 1 /2–14 NPT on 1 Optional /4–18 NPT on Drain/ Flange Traditional Flange for 1.7 (43) Vent Adapters. Pressure Connection Valve Adaptors Can Without the Use of Be Rotated to Flange Adapters. Give Connection Per IEC 1.1 3.4 1.1 2.126 Connection 61518 2.126 (54) (28) (87) (28) (54) Centers of 2.00 ±0.12 in. Connection (51), 2.126 (54), Centers or 2.25 (57). Dimensions are in inches (millimeters) 19 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 3051T Dimensional Drawings 1 /2–14 NPT 5.0 (127) Certification Conduit Label Connection (Two Places, Other 4.1 (105) 4.3 (110) Sizes Available) 0.75 (20) 0.75 (20) Clearance Clearance for for Cover Cover Removal Removal Transmitter Circuitry Terminal Connections 7.2 (183) Nameplate Housing Rotation Set Screw 3051T Typical Mounting Configurations with Optional Mounting Bracket Pipe Mounting Panel Mounting 4.3 2.9 (110) (72) 5.1 (130) 2 (50) 6.2 (156) 2.8 (71) 6.3 (160) 3.5 (90) 4.8 (120) 6.9 (175) Dimensions are in inches (millimeters) 20 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 3051H Pressure Transmitter Exploded View and Dimensional Drawings Secondary Filled System Sensor Module High Side Process Flange Process Isolating Diaphragm Low Side Process Flange Drain/Vent Valve Flange Bolts 1 /2–14 NPT 4.1 (105) 5.0 (127) Certification Conduit Connection Label (Two Places, Other 4.3 (110) Sizes Available) 0.75 (19) 0.75 (19) Clearance Clearance for for Cover Removal Cover Removal 9.0 Transmitter Terminal (228) Circuitry Housing Rotation Connections Set Screw Nameplate 10.8 (275) Drain/Vent Valve 3.4 1.1 1.2 (86) (28) (30) 1 /2–14 NPT on Optional Mounting Adapters. 1 /2–18 NPT on Process Flange for Pressure Connection Adapters Can Be Rotated Without the Use of Mounting Adapters to Give Adapter Connection Centers of 2.00 (51), 2.126 (54), or 2.25 (57). Dimensions are in inches (millimeters) 21 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 3051H Mounting Brackets for 2-in. Pipe and Panel Mount (Option Code B5/B6) Impulse Piping 2.7 (67) 0.7 (16) 4.4 (109) Impulse Piping 2.7 (67) Dimensions are in inches (millimeters) 22 PANEL MOUNTING CONFIGURATION PIPE MOUNTING CONFIGURATION 7 3 /16–20� /4 Bolts Supplied for Attaching Bracket to Transmitter Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 3051L Dimensional Drawings 2-in. Flange Configuring (Flush Mount Only) 3- and 4-in. Flange Configuration 4.1 (104) 4.1 (104) Housing Rotation Set Screw D E A A Extension H H 2, 4, or 6 (51, 102, or 152) Optional Flushing Connection Ring 5.0 (Lower Housing) (127) 4.3 G (109) F E 6.6 (168) 8.2 7.0 Flushing Connection (209) (179) Diaphragm Assembly and Mounting Flange B C Dimensions are in inches (millimeters) 23 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 10. 3051L Dimensional Specifications Except where indicated, dimensions are in inches (millimeters). Pipe Flange Bolt Circle Outside No. of Bolt Hole Extension O.D. Gasket (1) Class Size Thickness A Diameter B Diameter C Bolts Diameter Diameter D Surface E ASME B16.5 (ANSI) 150 2 (51) 0.69 (18) 4.75 (121) 6.0 (152) 4 0.75 (19) NA 3.6 (92) 3 (76) 0.88 (22) 6.0 (152) 7.5 (191) 4 0.75 (19) 2.58 (66) 5.0 (127) 4 (102) 0.88 (22) 7.5 (191) 9.0 (229) 8 0.75 (19) 3.5 (89) 6.2 (158) ASME B16.5 (ANSI) 300 2 (51) 0.82 (21) 5.0 (127) 6.5 (165) 8 0.75 (19) NA 3.6 (92) 3 (76) 1.06 (27) 6.62 (168) 8.25 (210) 8 0.88 (22) 2.58 (66) 5.0 (127) 4 (102) 1.19 (30) 7.88 (200) 10.0 (254) 8 0.88 (22) 3.5 (89) 6.2 (158) ASME B16.5 (ANSI) 600 2 (51) 1.00 (25) 5.0 (127) 6.5 (165) 8 0.75 (19) NA 3.6 (92) 3 (76) 1.25 (32) 6.62 (168) 8.25 (210) 8 0.88 (22) 2.58 (66) 5.0 (127) DIN 2501 PN 10–40 DN 50 20 mm 125 mm 165 mm 4 18 mm NA 4.0 (102) DIN 2501 PN 25/40 DN 80 24 mm 160 mm 200 mm 8 18 mm 65 mm 5.4 (138) DN 100 24 mm 190 mm 235 mm 8 22 mm 89 mm 6.2 (158) DIN 2501 PN 10/16 DN 100 20 mm 180 mm 220 mm 8 18 mm 89 mm 6.2 (158) Lower Housing G Pipe Process Class Size Side F 1/4 NPT 1/2 NPT H ASME B16.5 (ANSI) 150 2 (51) 2.12 (54) 0.97 (25) 1.31 (33) 5.65 (143) 3 (76) 3.6 (91) 0.97 (25) 1.31 (33) 5.65 (143) 4 (102) 3.6 (91) 0.97 (25) 1.31 (33) 5.65 (143) ASME B16.5 (ANSI) 300 2 (51) 2.12 (54) 0.97 (25) 1.31 (33) 5.65 (143) 3 (76) 3.6 (91) 0.97 (25) 1.31 (33) 5.65 (143) 4 (102) 3.6 (91) 0.97 (25) 1.31 (33) 5.65 (143) ASME B16.5 (ANSI) 600 2 (51) 2.12 (54) 0.97 (25) 1.31 (33) 7.65 (194) 3 (76) 3.6 (91) 0.97 (25) 1.31 (33) 7.65 (194) DIN 2501 PN 10–40 DN 50 2.4 (61) 0.97 (25) 1.31 (33) 5.65 (143) DIN 2501 PN 25/40 DN 80 3.6 (91) 0.97 (25) 1.31 (33) 5.65 (143) DN 100 3.6 (91) 0.97 (25) 1.31 (33) 5.65 (143) DIN 2501 PN 10/16 DN 100 3.6 (91) 0.97 (25) 1.31 (33) 5.65 (143) (1) Tolerances are 0.040 (1,02), –0.020 (0,51). 24 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Ordering Information TABLE 11. 3051C Differential, Gage, and Absolute Pressure Transmitters — = Not Applicable = Applicable Model Transmitter Type (Select One) CD CG CA 3051CD Differential Pressure Transmitter • — — 3051CG Gage Pressure Transmitter — • — 3051CA Absolute Pressure Transmitter — — • Code Pressure Ranges (Range/Min. Span) CD CG CA (1) 3051CD 3051CG 3051CA (2) 0 –3 to 3 inH O/0.1 inH O Not Applicable Not Applicable • — — 2 2 (–7,5 to 7,5 mbar/0,25 mbar) 1 –25 to 25 inH O/0.5 inH O –25 to 25 inH O/0.5 inH O 0 to 30 psia/0.3 psia • • • 2 2 2 2 (–62,2 to 62,2 mbar/1,2 mbar) (–62,1 to 62,2 mbar/1,2 mbar) (0 to 2,1 bar/20,7 mbar) 2 –250 to 250 inH2O/2.5 inH O –250 to 250 inH O/2.5 inH O 0 to 150 psia/1.5 psia • • • 2 2 2 (–623 to 623 mbar/6,2 mbar) (–621 to 623 mbar/6,2 mbar) (0 to 10,3 bar/0,1 bar) 3 –1000 to 1000 inH O/10 inH O –393 to 1000 inH O/10in H O 0 to 800 psia/8 psia • • • 2 2 2 2 (–2,5 to 2,5 bar/25 mbar) (–0,98 to 2,5 bar/25 mbar) (0 to 55,2 bar/0,55 bar) 4 –300 to 300 psi/3 psi –14.2 to 300 psi/3 psi 0 to 4000 psia/40 psia • • • (–20,7 to 20,7 bar/0,2 bar) (–0,98 to 20,7 bar/0,2 bar) (0 to 275,8 bar/2,8 bar) 5 –2000 to 2000 psi/20 psi –14.2 to 2000 psig/20 psi Not Applicable • • — (–137,9 to137,9 bar/1,4 bar) (–0,98 to 137,9 bar/1,4 bar) Code Output CD CG CA A 4–20 mA with Digital Signal Based on HART Protocol • • • (3) M •Low-Power, 1–5 V dc with Digital Signal Based on HART Protocol (See Option C2 for 0.8–3.2 V dc) F FOUNDATION fieldbus Protocol WProfibus — PA Code Materials of Construction CD CG CA Process Flange Type Flange Material Drain/Vent 2 Coplanar SST SST • • • (4) 3 Coplanar Alloy C Hastelloy C276 • • • 4 Coplanar Monel Monel • • • 5 Coplanar Plated CS SST ••• (4) 7 Coplanar SST Hastelloy C276 • • • (4) 8 Coplanar Plated CS Hastelloy C276 • • • 0 Alternate Flange—See Options on page 26 • • • Code Isolating Diaphragm CD CG CA (4) 2 316L SST ••• (4) 3 Hastelloy C276 • • • 4 Monel ••• 5 Tantalum (Available on 3051CD and CG, Ranges 2–5 only. Not available on 3051CA) • • — 6 Gold-plated Monel (Use in combination with O-ring Option Code B.) ••• 7 Gold-plated SST • • • Code O-ring A Glass-filled PTFE ••• B Graphite-filled PTFE • • • Code Fill Fluid CD CG CA 1 Silicone ••• 2 Inert fill (Halocarbon) • • — 25 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 11. 3051C Differential, Gage, and Absolute Pressure Transmitters — = Not Applicable = Applicable Code Housing Material Conduit Entry Size CD CG CA A Polyurethane-covered Aluminum ½–14 NPT • • • B Polyurethane-covered Aluminum M20 × 1.5 (CM20) • • • C Polyurethane-covered Aluminum PG 13.5 • • • D Polyurethane-covered Aluminum G½ • • • J SST ½–14 NPT • • • K SST M20 × 1.5 (CM20) • • • L SST PG 13.5 • • • M SST G½ • • • Code PlantWeb Functionality (Optional) CD CG CA A01 Advanced Control Function Block Suite ••• D01 FOUNDATION fieldbus Diagnostics Suite • • • Code Alternate Flange Options (Requires Materials of Construction Code 0) CD CG CA H2 Traditional Flange, 316 SST, SST Drain/Vent • • • (4) H3 Traditional Flange, Alloy C, Hastelloy C276 Drain/Vent • • • H4 Traditional Flange, Monel, Monel Drain/Vent • • • (4) H7 Traditional Flange, 316 SST, Hastelloy C276 Drain/Vent • • • 1 HJ DIN Compliant Traditional Flange, SST, /16 in. Adapter/Manifold Bolting • • • HK DIN Compliant Traditional Flange, SST, 10 mm Adapter/Manifold Bolting • • • HL DIN Compliant Traditional Flange, SST, 12mm Adapter/Manifold Bolting (Not available on 3051CD0) ••• FA Level Flange, SST, 2 in., ANSI Class 150, Vertical Mount • • • FB Level Flange, SST, 2 in., ANSI Class 300, Vertical Mount • • • FC Level Flange, SST, 3 in., ANSI Class 150, Vertical Mount • • • FD Level Flange, SST, 3 in., ANSI Class 300, Vertical Mount • • • FP DIN Level Flange, SST, DN 50, PN 40, Vertical Mount • • • FQ DIN Level Flange, SST, DN 80, PN 40, Vertical Mount • • • Code Integral Mount Manifold Options (Requires Materials of Construction Code 0) CD CG CA (5) S5 Assemble to Rosemount 305 Integral Manifold (specified separately, see the Rosemount 305 and 306 • • • Integral Manifolds PDS (document number 00813-0100-4733)) (5) S6 Assemble to Rosemount 304 Manifold or connection system • • • Code Integral Mount Primary Elements (Optional) CD CG CA (5) S4—— Factory Assembly to Rosemount Primary Element (Rosemount Annubar or Rosemount 1195 Integral Orifice) (With the primary element installed, the maximum operating pressure will equal the lesser of either the transmitter or the primary element. Option is available for factory assembly to range 1–4 transmitters only) (5)— — S3 Factory Assembly to Rosemount 405 Primary Element Diaphragm Seal Assemblies (Optional) Code NOTE: Standard flange and adapter bolts are austenitic 316 SST. CD CG CA (5) S1 One Diaphragm Seal (Direct Mount or Capillary Connection Type) • • • (5) S2 Two Diaphragm Seals (Direct Mount or Capillary Connection Type) • — — Optional All Welded Diaphragm Seal Systems (for high vacuum applications) Code NOTE: Standard flange and adapter bolts are austenitic 316 SST. CD CG CA (5) S7 One Diaphragm Seal, All-Welded System (Capillary Connection Type) • • • (5) S8 Two Diaphragm Seals, All-Welded System (Capillary Connection Type) • — — (5) S0 One Diaphragm Seal, All-Welded System (Direct Mount Connection Type) • • • (5) S9 Two Diaphragm Seals, All-Welded System (One Direct Mount and One Capillary Connection Type) • — — 26 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 11. 3051C Differential, Gage, and Absolute Pressure Transmitters — = Not Applicable = Applicable Code Mounting Bracket Options CD CG CA B4 Coplanar Flange Bracket for 2-in. Pipe or Panel Mounting, all SST • • • B1 Traditional Flange Bracket for 2-in. Pipe Mounting, CS Bolts • • • B2 Traditional Flange Bracket for Panel Mounting, CS Bolts • • • B3 Traditional Flange Flat Bracket for 2-in. Pipe Mounting, CS Bolts • • • B7 B1 Bracket with Series 300 SST Bolts • • • B8 B2 Bracket with Series 300 SST Bolts • • • B9 B3 Bracket with Series 300 SST Bolts • • • BA SST B1 Bracket with Series 300 SST Bolts • • • BC SST B3 Bracket with Series 300 SST Bolts • • • Code Hazardous Locations Certification Options CD CG CA E5 FM Explosionproof Approval • • • I5 FM Non-incendive and Intrinsic Safety Approval • • • IE FM FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only • • • K5 FM Explosionproof and Intrinsic Safety Approval • • • (6)I1 ATEX Intrinsic Safety (6) N1 ATEX Type N and Dust Certification E8 ATEX Flame-proof and Dust Certification (6) E4 TIIS Flame-proof Certification — I4 TIIS Intrinsic Safety Certification (Only available with HART Option Code A) (7) C5 Measurement Canada Accuracy Approval (Limited availability depending on transmitter type and range. Contact an Emerson Process Management representative) C6 CSA Explosion-proof and Intrinsic Safety Approval (6) K6 CSA and ATEX Explosion-proof and Intrinsic Safety Approval (combination of C6 and K8) KB FM and CSA Explosion-proof and Intrinsic Safety Approvals (combination of K5 and C6) K7 SAA Flame-proof and Intrinsic Safety Approvals (combination of I7, N7, and E7) (6)K8 ATEX Flame-proof and Intrinsic Safety Approvals (combination of I1 and E8) (6) KD FM, CSA, and ATEX Explosion-proof and Intrinsically Safe combination of K5, C6, I1, and E8 I7 SAA Intrinsic Safety Certification E7 SAA Flame-proof Certification N7 SAA Type N Certification IA ATEX Intrinsic Safety for FISCO; for FOUNDATION fieldbus protocol only Code Bolting Options CD CG CA L4 Austenitic 316 SST Bolts • • • L5 ASTM A 193, Grade B7M Bolts • • • L6 Monel Bolts ••• Code Display Options CD CG CA M5 LCD display for Aluminum Housing (Housing Codes A, B, C, and D only) • • • M6 LCD display for SST Housing (Housing Codes J, K, L, and M only) • • • 27 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 11. 3051C Differential, Gage, and Absolute Pressure Transmitters — = Not Applicable = Applicable Code Other Options CD CG CA Q4 Calibration Data Sheet ••• Q8 Material Traceability Certification per EN 10204 3.1.B (Only available for the sensor module housing and Coplanar or traditional flanges and adapters (3051C), and for the sensor module housing and low-volume Coplanar flange and adapter (3051C with Option Code S1)) Q16 Surface finish certification for sanitary remote seals QZ Remote Seal System Performance Calculation Report QP Calibration certification and tamper evident seal QS Certificate of FMEDA Data (7)(8)J1 Local Zero Adjustment Only (7)(8)J3 No Local Zero or Span Adjustment T1 Transient Protection Terminal Block (7) C1 Custom Software Configuration (Completed CDS 00806-0100-4001 required with order) • • • (7)C2 0.8–3.2 V dc Output with Digital Signal Based on HART Protocol (Output Code M only) C3 Gage Calibration (3051CA4 only) — — • (7)(9)C4 Analog Output Levels Compliant with NAMUR Recommendation NE 43 (7)(9)CN Analog Output Levels Compliant with NAMUR Recommendation NE 43 Alarm Configuration–Low P1 Hydrostatic Testing with Certificate • • • P2 Cleaning for Special Service • • • P3 Cleaning for <1 PPM Chlorine/Fluorine • • • P4 Calibrate at line pressure (Specify Q48 on order for corresponding certificate) 1 DF /2 -14 NPT flange adapter(s)— Material determined by flange material D7 Coplanar Flange Without Drain/Vent Ports • • • D8 Ceramic Ball Drain/Vents • • • D9 JIS Process Connection—RC ¼ Flange with RC ½ Flange Adapter • • • P8 0.04% accuracy to 5:1 turndown (Range 2-4) • • • P9 4500 psig Static Pressure Limit (3051CD Ranges 2–5 only) • — — (10) V5 External Ground Screw Assembly • • • Typical Model Number: 3051CD 2 A 2 2 A 1 A B4 (1) 3051CG lower range limit varies with atmospheric pressure. (2) 3051CD0 is available only with Output Code A, Process Flange Code 0 (Alternate Flange H2, H7, HJ, or HK), Isolating Diaphragm Code 2, O-ring Code A, and Bolting Option L4. (3) Not available with hazardous locations certification Options Codes I1, N1, E4, K6 and K8. (4) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments. (5) “Assemble-to” items are specified separately and require a completed model number. (6) Not available with Low Power code M. (7) Not available with Fieldbus (output code F) or Profibus (output code W). (8) Local zero and span adjustments are standard unless Option Code J1 or J3 is specified (9) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field. (10) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option. 28 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 12. 3051T Gage and Absolute Pressure Transmitter Model Transmitter Type 3051T Pressure Transmitter Code Pressure Type G Gage A Absolute Code Pressure Ranges (Range/Min. Span) (1) 3051TG 3051TA 1 –14.7 to 30 psi/0.3 psi (–1,01 to 2,1 bar/20,7 mbar) 0 to 30 psia/0.3 psia (0 to 2,1 bar/20,7 mbar) 2 –14.7 to 150 psi/1.5 psi (–1,01 to 10,3 bar/103,4 mbar) 0 to 150 psia/1.5 psia (0 to 10,3 bar/103,4 mbar) 3 –14.7 to 800 psi/8 psi (–1,01 to 55,2 bar/0,55 bar) 0 to 800 psia/8 psia (0 to 55,2 bar/0,55 bar) 4 –14.7 to 4000 psi/40 psi (–1,01 to 275,8 bar/2,8 bar) 0 to 4000 psia/40 psia (0 to 275,8 bar/2,8 bar) 5 –14.7 to 10000 psi/2000 psi (–1,01 to 689,5 bar/138 bar) 0 to 10000 psia/2000 psia (0 to 689,5 bar/138 bar) Code Output A 4–20 mA with Digital Signal Based on HART Protocol M Low-Power 1–5 V dc with Digital Signal Based on HART Protocol (See Option Code C2 for 0.8–3.2 V dc Output) (Not available with hazardous certification Option Codes I1, N1, E4, K6 or K8) F FOUNDATION fieldbus Protocol W Profibus — PA Code Process Connection Style 1 2B /2–14 NPT Female 2C G½ A DIN 16288 Male (Available in SST for Range 1–4 only) 2F Coned and Threaded, Compatible with Autoclave Type F-250-C (Only available in SST for Range 5) Code Isolating Diaphragm Process Connection Wetted Parts Material (2) 2 316L SST 316L SST (2) 3 Hastelloy C276 Hastelloy C276 Code Fill Fluid 1 Silicone ® 2 Inert (Fluorinert FC-43) Code Housing Material Conduit Entry Size A Polyurethane-covered Aluminum ½–14 NPT B Polyurethane-covered Aluminum M20 × 1.5 (CM20) C Polyurethane-covered Aluminum PG 13.5 D Polyurethane-covered Aluminum G½ J SST ½–14 NPT K SST M20 × 1.5 (CM20) L SST PG 13.5 M SST G½ Code PlantWeb Functionality (Optional) A01 Advanced Control Function Block Suite D01 FOUNDATION fieldbus Diagnostics Suite Code Integral Mount Manifold (Optional) (3) S5 Assemble to Rosemount 306 Integral Manifold (specified separately, see the Rosemount 305 and 306 Integral 1 Manifolds PDS (document number 00813-0100-4733)) (Requires /2-in. process connection code 2B) Code Remote Diaphragm Seals Assemblies (Optional) (3) S1 One remote diaphragm seal (Direct Mount or Capillary Connection Type) (Requires Process Connection Style code 2B) Code Mounting Brackets (Optional) B4 Bracket for 2-in. Pipe or Panel Mounting, All SST 29 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 12. 3051T Gage and Absolute Pressure Transmitter Code Hazardous Locations Certifications (Optional) E5 FM Explosion-proof Approval I5 FM Non-incendive and Intrinsic Safety Approval IE FM FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only K5 FM Explosion-proof and Intrinsic Safety Approval C5 Measurement Canada accuracy approval (Limited availability depending on transmitter type and range. Contact an Emerson Process Management representative) C6 CSA Explosion-proof and Intrinsic Safety Approval (4) K6 CSA and ATEX Explosion-proof and Intrinsic Safety Approval (combination of C6 and K8) KB FM and CSA Explosion-proof and Intrinsic Safety Approvals (combination of K5 and C6) K7 SAA Flame-proof and Intrinsic Safety Approvals (combination of I7, N7, and E7) (4) K8 ATEX Flame-proof and Intrinsic Safety Approvals (combination of I1 and E8) (4) KD CSA, FM, and ATEX Explosion-proof and Intrinsic Safety Approval (combination of K5, C6, I1, and E8) I7 SAA Intrinsic Safety Certification (4) E4 TIIS Flame-proof Certification E7 SAA Flame-proof Certification N7 SAA Type N Certification (4) I1 ATEX Intrinsic Safety and Dust Certification (4) N1 ATEX Type N and Dust Certification E8 ATEX Flame-proof and Dust Certification DW NSF drinking water approval IA ATEX Intrinsic Safety for FISCO; for FOUNDATION fieldbus protocol only Code Other Options Q4 Calibration Data Sheet Q8 Material Traceability Certification per EN 10204 3.1.B NOTE: This option applies to the process connection only. Q16 Surface finish certification for sanitary remote seals QZ Remote Seal System Performance Calculation Report QP Calibration certification and tamper evident seal QS Certificate of FMEDA Data (5)(6) J1 Local Zero Adjustment Only (5)(6) J3 No Local Zero or Span Adjustment M5 LCD display for Aluminum Housing (Housing Codes A, B, C, and D only) M6 LCD display for SST Housing (Housing Codes J, K, L and M only) T1 Transient Protection Terminal Block (5) C1 Custom Software Configuration (Completed CDS 00806-0100-4001 required with order) (5) C2 0.8–3.2 V dc Output with Digital Signal Based on HART Protocol (Output Code M only) (5)(7) C4 Analog Output Levels Compliant with NAMUR Recommendation NE 43, 27-June-1996. (5)(7) CN Analog Output Levels Compliant with NAMUR Recommendation NE 43: Low Alarm Configuration P1 Hydrostatic Testing with Certificate P2 Cleaning for Special Service P3 Cleaning for <1 PPM Chlorine/Fluorine P8 0.04% accuracy to 5:1 turndown (Range 1-4) (8) V5 External Ground Screw Assembly Typical Model Number: 3051T G 5 F 2A 2 1 A B4 (1) 3051TG lower range limit varies with atmospheric pressure. (2) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments. (3) “Assemble-to” items are specified separately and require a completed model number. (4) Not available with low-power Option Code M. (5) Not available with fieldbus (output code F) or Profibus protocols (output code W). (6) Local zero and span adjustments are standard unless Option Code J1 or J3 is specified. (7) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field. (8) The V5 option is not needed with T1 option; external ground screw assembly is included with the T1 option. 30 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 13. 3051L Flange-Mounted Liquid Level Transmitter Model Transmitter Type 3051L Flange-Mounted Liquid Level Transmitter Code Pressure Ranges (Range/Min. Span) 2 –250 to 250 inH O/2.5 inH O (–0,6 to 0,6 bar/6,2 mbar) 2 2 3 –1000 to 1000 inH O/10 inH O (–2,5 to 2,5 bar/25 mbar) 2 2 4 –300 to 300 psi/3 psi (–20,7 to 20,7 bar/0,2 bar) Code Output A 4–20 mA with Digital Signal Based on HART Protocol M Low-Power 1–5 V dc with Digital Signal Based on HART Protocol (See Option Code C2 for 0.8–3.2 V dc Output) (Not available with hazardous certification Option Codes I1, N1, E4, K6, and K8) F FOUNDATION fieldbus Protocol W Profibus – PA High Pressure Side Code Diaphragm Size Material Extension Length G0 2 in./DN 50 316L SST Flush Mount Only H0 2 in./DN 50 Hastelloy C276 Flush Mount Only J0 2 in./DN 50 Tantalum Flush Mount Only A0 3 in./DN 80 316L SST Flush Mount A2 3 in./DN 80 316L SST 2 in./50 mm A4 3 in./DN 80 316L SST 4 in./100 mm A6 3 in./DN 80 316L SST 6 in./150 mm B0 4 in./DN 100 316L SST Flush Mount B2 4 in./DN 100 316L SST 2 in./50 mm B4 4 in./DN 100 316L SST 4 in./100 mm B6 4 in./DN 100 316L SST 6 in./150 mm C0 3 in./DN 80 Hastelloy C276 Flush Mount C2 3 in./DN 80 Hastelloy C276 2 in./50 mm C4 3 in./DN 80 Hastelloy C276 4 in./100 mm C6 3 in./DN 80 Hastelloy C276 6 in./150 mm D0 4 in./DN 100 Hastelloy C276 Flush Mount D2 4 in./DN 100 Hastelloy C276 2 in./50 mm D4 4 in./DN 100 Hastelloy C276 4 in./100 mm D6 4 in./DN 100 Hastelloy C276 6 in./150 mm E0 3 in./DN 80 Tantalum Flush Mount Only F0 4 in./DN 100 Tantalum Flush Mount Only 31 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 13. 3051L Flange-Mounted Liquid Level Transmitter Code Mounting Flange Size ASME B 16.5 (ANSI) or DIN Flange Rating Material M 2 in. Class 150 CS A 3 in. Class 150 CS B 4 in. Class 150 CS N 2 in. Class 300 CS C 3 in. Class 300 CS D 4 in. Class 300 CS P 2 in. Class 600 CS E 3 in. Class 600 CS X 2 in. Class 150 SST F 3 in. Class 150 SST G 4 in. Class 150 SST Y 2 in. Class 300 SST H 3 in. Class 300 SST J 4 in. Class 300 SST Z 2 in. Class 600 SST L 3 in. Class 600 SST Q DN 50 PN 10-40 CS R DN 80 PN 40 CS S DN 100 PN 40 CS V DN 100 PN 10/16 CS K DN 50 PN 10-40 SST T DN 80 PN 40 SST U DN 100 PN 40 SST W DN 100 PN 10/16 SST Code Process Fill-High Pressure Side Temperature Limits A Syltherm XLT –100 to 300 °F (–73 to 135 °C) C D. C. Silicone 704 60 to 400 °F (15 to 205 °C) D D. C. Silicone 200 –40 to 400 °F (–40 to 205 °C) H Inert (Halocarbon) –50 to 350 °F (–45 to 177 °C) G Glycerine and Water 0 to 200 °F (–17 to 93 °C) N Neobee M-20 0 to 400 °F (–17 to 205 °C) P Propylene Glycol and Water 0 to 200 °F (–17 to 93 °C) Low Pressure Side Flange Adapter Sensor Fill Fluid Code Configuration Diaphragm Material 11 Gage SST 316L SST Silicone 21 Differential SST 316L SST Silicone 22 Differential SST Hastelloy C276 Silicone 2A Differential SST 316L SST Inert (Halocarbon) 2B Differential SST Hastelloy C276 Inert (Halocarbon) 31 Remote Seal SST 316L SST Silicone (Requires Option Code S1) Code O-ring Material A Glass-filled PTFE 32 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 13. 3051L Flange-Mounted Liquid Level Transmitter Code Housing Material Conduit Entry Size A Polyurethane-covered Aluminum ½–14 NPT B Polyurethane-covered Aluminum M20 × 1.5 (CM20) C Polyurethane-covered Aluminum PG 13.5 D Polyurethane-covered Aluminum G½ J SST ½–14 NPT K SST M20 × 1.5 (CM20) L SST PG 13.5 M SST G½ Code PlantWeb Functionality (Optional) A01 Advanced Control Function Block Suite D01 FOUNDATION fieldbus Diagnostics Suite Code Diaphragm Seal Assemblies (Optional) (1) S1 One Diaphragm Seal (requires low pressure side Option Code 31 capillary connection type) Code Hazardous Locations Certification Options E5 FM Explosion-proof Approval I5 FM Non-incendive and Intrinsic Safety Approval IE FM FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only K5 FM Explosion-proof and Intrinsic Safety Approval (2) I1 ATEX Intrinsic Safety and Dust Certification (2) N1 ATEX Type N and Dust Certification E8 ATEX Flame-proof and Dust Certification (2) E4 TIIS Flame-proof Certification C6 CSA Explosion-proof and Intrinsic Safety Approval (2) K6 CSA and ATEX Explosion-proof and Intrinsic Safety Approval (combination of C6 and K8) KB FM and CSA Explosion-proof and Intrinsic Safety Approvals (combination of K5 and C6) K7 SAA Flame-proof and Intrinsic Safety Approvals (combination of I7, N7, and E7) (2) K8 ATEX Flame-proof and Intrinsic Safety Approvals (combination of I1 and E8) (2) KD CSA, FM, and ATEX Explosion-proof and Intrinsic Safety Approval (combination of K5, C6, I1, and E8) I7 SAA Intrinsic Safety Certification E7 SAA Flame-proof Certification N7 SAA Type N Certification IA ATEX Intrinsic Safety for FISCO; for FOUNDATION fieldbus protocol only Code Bolt for Flange and Adapters (Optional) L5 ASTM A 193, Grade B7M Bolts Code Display Options M5 LCD display for Aluminum Housing (Available with Housing codes A, B, C, and D only) M6 LCD display for SST Housing (Available with Housing codes J, K, L, and M only) 33 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 13. 3051L Flange-Mounted Liquid Level Transmitter Code Other Options Q4 Calibration Data Sheet Q8 Material Traceability Certification per EN 10204 3.1.B (Available with the diaphragm, upper housing, Coplanar flange, adapter, sensor module housing, lower housing/flushing connection, and extension) QZ Remote Seal System Performance Calculation Report QP Calibration certification and tamper evident seal (3)(4) J1 Local Zero Adjustment Only (3)(4) J3 No Local Zero or Span Adjustment T1 Transient Protection Terminal Block (3) C1 Custom Software Configuration (Completed CDS 00806-0100-4001 required with order) (3) C2 0.8–3.2 V dc Output with Digital Signal Based on HART Protocol (Available with Output code M only) (3)(5) C4 Analog Output Levels Compliant with NAMUR Recommendation NE 43 (3)(5) CN Analog Output Levels Compliant with NAMUR Recommendation NE 43: Alarm Configuration–Low D8 Ceramic Ball Drain/Vents (6) V5 External Ground Screw Assembly Diaphragm /Size Code Lower Housing Flushing Connections Options Ring Material Number Size 2 in. 3 in. 4 in. 1 F1 SST 1 /4 • • • 1 F2 SST 2 /4 • • • (7) 1 F3 Hastelloy C276 1 /4 • • • (7) 1 F4 Hastelloy C276 2 /4 • • • 1 F7 SST 1 /2 • • • 1 F8 SST 2 /2 • • • 1 F9 Hastelloy C276 1 /2 • • • 1 F0 Hastelloy C276 2 /2 • • • Typical Model Number: 3051L__2__A__A0__D _21__A__A__F1 (1) “Assemble-to” items are specified separately and require a completed model number. (2) Not available with low-power Option Code M (3) Not available with fieldbus (output code F) or profibus protocols (output code W). (4) Local zero and span adjustments are standard unless Option Code J1 or J3 is specified. (5) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field. (6) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option. (7) Not available with Option Codes A0, B0, and G0. 34 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 14. 3051H Pressure Transmitter for High-Temperature Processes — = Not Applicable = Applicable Model Transmitter Type (Select One) HD HG 3051HD Differential Pressure Transmitter for High-Temperature Processes • — 3051HG Gage Pressure Transmitter for High-Temperature Processes — • Code Pressure Ranges (Range/ Min. Span) 3051HD 3051HG 2 –250 to 250 inH O/2.5 inH O –250 to 250 inH O/2.5 inH O 2 2 2 2 (–0,62 to 0,62 bar/6,2 mbar) (–0,62 to 0,62 bar/6,2 mbar) 3 –1000 to 1000 inH O/10 inH O –407 to 1000 inH O/10in H O 2 2 2 2 (–2,5 to 2,5 bar/25 mbar) (–1,01 to 2,5 bar/25 mbar) 4 –300 to 300 inH O/3 psi –14.7 to 300 psi/3 psi 2 (–747 to 747 mbar/0,2 bar) (–1,01 to 20,7 bar/0,2 bar) 5 –2000 to 2000 psi/20 psi –14.7 to 2000 psig/20 psi (–138 to 138 bar/1,4 bar) (–1,01 to 138 bar/1,4 bar) NOTE: 3051HG lower range limit varies with atmospheric pressure. Code Output HD HG A 4–20 mA with Digital Signal Based on HART Protocol • • M Low-Power 1–5 V dc with Digital Signal Based on HART Protocol (See Option Code C2 for 0.8–3.2 V dc Output) • • (Not available with hazardous certification Option Codes I1, N1, E4, K6, and K8) • • F FOUNDATION fieldbus Protocol • • W Profibus – PA Code Process Connection HD HG Process Flange Material Drain/Vent 2 SST SST • • (1) 7 SST Hastelloy C276 • • Code Process Isolating Diaphragm HD HG 2 316L SST • • (1) 3 Hastelloy C276 • • 5 Tantalum • • Code O-ring Material HD HG A Glass-Filled PTFE • • Code Process Fill Fluid HD HG D D.C. 200 Silicone • • H Inert • • N Neobee M-20 • • Code Sensor Module Isolator Material HD HG 2 SST • • Code Sensor Module Fill Fluid HD HG 1 Silicone • • 2 Inert (Halocarbon) • • Code Housing Material Conduit Entry Size HD HG A Polyurethane-covered Aluminum ½–14 NPT • • B Polyurethane-covered Aluminum M20 × 1.5 (CM20) • • C Polyurethane-covered Aluminum PG 13.5 • • D Polyurethane-covered Aluminum G½ • • J SST ½–14 NPT • • K SST M20 × 1.5 (CM20) • • L SST PG 13.5 • • M SST G½ • • Code PlantWeb Functionality (Optional) A01 Advanced Control Function Block Suite D01 FOUNDATION fieldbus Diagnostics Suite Code Integral Mount Primary Elements (Optional) HD HG (2) S4 Factory Assembly to Rosemount Primary Element (Rosemount Annubar or Rosemount 1195 Integral Orifice) • — (With the primary element installed, the maximum operating pressure will equal the lesser of either the transmitter or the primary element. Option is available for factory assembly to range 1–4 transmitters only) 35 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 TABLE 14. 3051H Pressure Transmitter for High-Temperature Processes — = Not Applicable = Applicable Code Mounting Bracket Options HD HG B5 Universal Mounting Bracket for 2-in. Pipe or Panel Mount, CS Bolts • • B6 Universal Mounting Bracket for 2-in. Pipe or Panel Mount, SST Bolts • • Code Hazardous Locations Certification Options HD HG E5 FM Explosion-proof Approval • • I5 FM Non-incendive and Intrinsic Safety Approval • • K5 FM Explosion-proof and Intrinsic Safety Approval • • (3) I1 ATEX Intrinsic Safety and Dust Certification • • (3) N1 ATEX Type N and Dust Certification • • E8 ATEX Flame-proof and Dust Certification • • (3) E4 TIIS Flame-proof Certification • • C6 CSA Explosion-proof and Intrinsic Safety Approval • • (3) K6 CSA and ATEX Explosion-proof and Intrinsic Safety Approval (combination of C6 and K8) • • KB FM and CSA Explosion-proof and Intrinsic Safety Approvals (combination of K5 and C6) • • K7 SAA Flame-proof and Intrinsic Safety Approvals (combination of I7, N7, and E7) • • (3) KB ATEX Flame-proof and Intrinsic Safety Approvals (combination of I1 and E8) • • (3) KD CSA, FM, and ATEX Explosion-proof and Intrinsic Safety Approval (combination of K5, C6, I1, and E8) • • I7 SAA Intrinsic Safety Certification • • E7 SAA Flame-proof Certification • • N7 SAA Type N Certification • • IA ATEX Intrinsic Safety for FISCO; for FOUNDATION fieldbus protocol only • • IE FM FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only • • Code Bolt for Flange and Adapter Options HD HG L4 Austenitic 316 SST Bolts • • Code Display Options HD HG M5 LCD display for Aluminum Housing (Available with Housing codes A, B, C, and D only) • • M6 LCD display for SST Housing (Available with Housing codes J, K, L, and M only) • • Code Other Options HD HG Q4 Calibration Data Sheet • • Q8 Material traceability certification per EN 10204 3.1.B • • QP Calibration certification and tamper evident seal • • (4) J1 Local Zero Adjustment Only (Local zero and span adjustments are standard unless Option • • Code J1 or J3 is specified.) (4) J3 No Local Zero or Span Adjustment (Local zero and span adjustments are standard unless • • Option Code J1 or J3 is specified) T1 Transient Protection Terminal Block • • (4) C1 Custom Software Configuration (Completed CDS 00806-0100-4001 required with order) • • (4) C2 0.8–3.2 V dc Output with Digital Signal Based on HART Protocol (Output Code M only) • • (4)(5) C4 Analog Output Levels Compliant with NAMUR Recommendation NE 43 • • (4)(5) CN Analog Output Levels Compliant with NAMUR Recommendation NE 43: Alarm Configuration–Low • • P1 Hydrostatic Testing with Certificate • • P2 Cleaning for Special Service • • P3 Cleaning for <1 PPM Chlorine/Fluorine • • 1 DF /2–14 NPT flange adapters—SST • • D8 Ceramic Ball Drain/Vents • • (6) V5 External Ground Screw Assembly • • Typical Model Number: 3051HG 2 A 2 2 A H 2 1 A B5 (1) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments. (2) “Assemble-to” items are specified separately and require a completed model number. (3) Not available with low-power Option Code M. (4) Not available with fieldbus (output code F) or profibus protocols (output code W). (5) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field. (6) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option. 36 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Optional Diaphragm and Sanitary Seals OPTIONS Refer to Product Data Sheet 00813-0100-4016 or 00813-0201-4016. for additional information. Standard Configuration Unless otherwise specified, transmitter is shipped (1) Output Information as follows: Output range points must be the same unit of measure. Available ENGINEERING UNITS units of measure include: Differential/Gage: inH O (Range 0, 1, 2, and 3) psi 2 (1) inH2O inH2O@4 °C psi Pa (Range 4 and 5) inHg ftH2O bar kPa Absolute/3051T: psi (all ranges) (1) (1) mmH2O mmH2O@4 °C mbar torr 4 mA (1 V dc) : 0 (engineering units above) mmHg g/cm2 kg/cm2 atm 20 mA (5 V dc): Upper range limit Output: Linear (1) Not available on low power or previous versions. Flange type: Specified model code option LCD display Flange material: Specified model code option O-ring material: M5 Digital Display, 5-Digit, 2-Line LCD Specified model code option Drain/vent: • Direct reading of digital data for Specified model code option higher accuracy Integral meter: Installed or none (1) • Displays user-defined flow, level, volume, or pressure units Alarm : Upscale Software tag: • Displays diagnostic messages for local troubleshooting (Blank) • 90-degree rotation capability for easy viewing (1) Not applicable to fieldbus. M6 Digital Display with 316 Stainless Steel Cover (1) • For use with stainless steel housing option (housing codes J, Custom Configuration HART protocol only K, and L) If Option Code C1 is ordered, the customer may specify the following data in addition to the standard configuration parameters. (2) Local Span and Zero Adjustment • Output Information Transmitters ship with local span and zero adjustments standard • Transmitter Information unless otherwise specified. • LCD display Configuration • Non-interactive external zero and span adjustments ease • Hardware Selectable Information calibration • Signal Selection • Magnetic switches replace standard potentiometer Refer to the “HART Protocol C1 Option Configuration Data Sheet” adjustments to optimize performance document number 00806-0100-4001. (1) J1 Local Zero Adjustment Only (1) J3 No Local Zero or Span Adjustment Tagging (3 options available) • Standard SST hardware tag is wired to the transmitter. Tag Transient Protection character height is 0.125 in. (3,18 mm), 56 characters T1 Integral Transient Protection Terminal Block maximum. • Integral transient protection terminal block • Tag may be permanently stamped on transmitter nameplate • Meets IEEE Standard 587, Category B upon request, 56 characters maximum. 1 kV crest (10 � 1 000 microseconds) • Tag may be stored in transmitter memory (30 characters 3 kV crest (8 � 20 microseconds) maximum). Software tag is left blank unless specified. 6 kV crest (1.2 � 50 microseconds) • Meets IEEE Standard 472, Commissioning tag (fieldbus only) Surge Withstand Capability A temporary commissioning tag is attached to all transmitters. The SWC 2,5 kV crest, 1 MHz wave form tag indicates the device ID and allows an area for writing the • Applicable standards: IEC 801-4, 801-5 location. Bolts for Flanges and Adapters Optional Rosemount 304, 305 or 306 Integral Manifolds • Options permit bolts for flanges and adapters to be obtained in Factory assembled to 3051C and 3051T transmitters. Refer to the various materials following Product Data Sheet (document number • Standard material is plated carbon steel per ASTM A449, Type 1 00813-0100-4839 for Rosemount 304 and 00813-0100-4733 for Rosemount 305 and 306) for additional information. L4 Austenitic 316 Stainless Steel Bolts L5 ASTM A 193, Grade B7M Bolts L6 Monel Bolts (1) Not applicable to fieldbus. (2) Not applicable to fieldbus. 37 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Rosemount 3051C Coplanar Flange and 3051T Bracket Shipping Weights Option TABLE 15. Transmitter Weights without Options B4 Bracket for 2-in. Pipe or Panel Mounting Transmitter Add Weight In lb (kg) • For use with the standard Coplanar 3051C 6.0 (2,7) flange configuration 3051L Table 16 on page 38 • Bracket for mounting of transmitter on 2-in. pipe or panel 3051H 13.6 (6,2) • Stainless steel construction with stainless steel bolts 3051T 3.0 (1,4) Rosemount 3051H Bracket Options B5 Bracket for 2-in. Pipe or Panel Mounting TABLE 16. 3051L Weights without Options • For use with the 3051H Pressure Transmitter for high process Flush 2-in. Ext. 4-in. Ext. 6-in. Ext. temperatures Flange lb. (kg) lb (kg) lb (kg) lb (kg) • Carbon steel construction with carbon 2-in., 150 12.5 (5,7) — — — steel bolts 3-in., 150 17.5 (7,9) 19.5 (8,8) 20.5 (9,3) 21.5 (9,7) B6 B5 Bracket with SST Bolts 4-in., 150 23.5 (10,7) 26.5 (12,0) 28.5 (12,9) 30.5 (13,8) • Same bracket as the B5 option with Series 300 stainless steel bolts. 2-in., 300 17.5 (7,9) — — — 3-in., 300 22.5 (10,2) 24.5 (11,1) 25.5 (11,6) 26.5 (12,0) Traditional Flange Bracket Options 4-in., 300 32.5 (14,7) 35.5 (16,1) 37.5 (17,0) 39.5 (17,9) B1 Bracket for 2-in. Pipe Mounting 2-in., 600 15.3 (6,9) — — — • For use with the traditional flange option 3-in., 600 25.2 (11,4) 27.2 (12,3) 28.2 (12,8) 29.2 (13,2) • Bracket for mounting on 2-in. pipe DN 50/PN 40 13.8 (6,2) — — — • Carbon steel construction with carbon DN 80/PN 40 19.5 (8,8) 21.5 (9,7) 22.5 (10,2) 23.5 (10,6) steel bolts DN 100/ 17.8 (8,1) 19.8 (9,0) 20.8 (9,5) 21.8 (9,9) PN 10/16 • Coated with polyurethane paint DN 100/ 23.2 (10,5) 25.2 (11,5) 26.2 (11,9) 27.2 (12,3) B2 Bracket for Panel Mounting PN 40 • For use with the traditional flange option • Bracket for mounting transmitter on wall or panel TABLE 17. Transmitter Options Weights • Carbon steel construction with carbon Add steel bolts Code Option lb (kg) • Coated with polyurethane paint J, K, L, M Stainless Steel Housing(T) 3.9 (1,8) B3 Flat Bracket for 2-in. Pipe Mounting J, K, L, M Stainless Steel Housing (C, L, H, P) 3.1 (1,4) • For use with the traditional flange option M5 LCD display for Aluminum Housing 0.5 (0,2) • Bracket for vertical mounting of transmitter on 2-in. pipe M6 LCD display for SST Housing 1.25 (0,6) • Carbon steel construction with carbon B4 SST Mounting Bracket for Coplanar Flange 1.0 (0,5) steel bolts B1 B2 B3 Mounting Bracket for Traditional Flange 2.3 (1,0) • Coated with polyurethane paint B7 B8 B9 Mounting Bracket for Traditional Flange 2.3 (1,0) B7 B1 Bracket with SST Bolts BA, BC SST Bracket for Traditional Flange 2.3 (1,0) • Same bracket as the B1 option with Series 300 stainless steel B5 B6 Mounting Bracket for 3051H 2.9 (1,3) bolts H2 Traditional Flange 2.4 (1,1) B8 B2 Bracket with SST Bolts H3 Traditional Flange 2.7 (1,2) • Same bracket as the B2 option with Series 300 stainless steel H4 Traditional Flange 2.6 (1,2) bolts H7 Traditional Flange 2.5 (1,1) B9 B3 Bracket with SST Bolts FC Level Flange—3 in., 150 10.8 (4,9) • Same bracket as the B3 option with Series 300 stainless steel FD Level Flange—3 in., 300 14.3 (6,5) bolts FA Level Flange—2 in., 150 10.7 (4,8) BA Stainless Steel B1 Bracket with SST Bolts FB Level Flange—2 in., 300 14.0 (6,3) • B1 bracket in stainless steel with Series 300 stainless steel FP DIN Level Flange, SST, DN 50, PN 40 8.3 (3,8) bolts FQ DIN Level Flange, SST, DN 80, PN 40 13.7 (6,2) BC Stainless Steel B3 Bracket with SST Bolts • B3 bracket in stainless steel with Series 300 stainless steel bolts 38 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 3051C Differential/Gage Pressure Transmitter Range Limits Range 1 Span Range 2 Span Range 3 Span Range 4 Span Range 5 Span Units min max min max min max min max min max inH O 0.5 25 2.5 250 10 1000 83.040 8304 553.60 55360 2 inHg 0.03678 1.8389 0.18389 18.389 0.73559 73.559 6.1081 610.81 40.720 4072.04 ftH O 0.04167 2.08333 0.20833 20.8333 0.83333 83.3333 6.9198 691.997 46.13 4613.31 2 mmH O 12.7 635.5 63.553 6355 254 25421 2110.95 211095 14073 1407301 2 mmHg 0.93416 46.7082 4.67082 467.082 18.6833 1868.33 155.145 15514.5 1034.3 103430 psi 0.01806 0.903 0.0902 9.03183 0.36127 36.127 3 300 20 2000 bar 0.00125 0.06227 0.00623 0.62272 0.02491 2.491 0.20684 20.6843 1.37895 137.895 mbar 1.2454 62.2723 6.22723 622.723 24.9089 2490.89 206.843 20684.3 1378.95 137895 2 g/cm 1.26775 63.3875 6.33875 633.875 25.355 2535.45 210.547 21054.7 1406.14 140614 2 kg/cm 0.00127 0.0635 0.00635 0.635 0.0254 2.54 0.21092 21.0921 1.40614 140.614 Pa 124.545 6227.23 622.723 62160.6 2490.89 249089 20684.3 2068430 137895 13789500 kPa 0.12545 6.2272 0.62272 62.2723 2.49089 249.089 20.6843 2068.43 137.895 13789.5 torr 0.93416 46.7082 4.67082 467.082 18.6833 1868.33 155.145 15514.5 1034.3 103430 atm 0.00123 0.06146 0.00615 0.61460 0.02458 2.458 0.20414 20.4138 1.36092 136.092 When using a HART communicator, ±5% adjustment is allowed on the sensor limit to allow for unit conversions. 3051L/3051H Pressure Transmitter Range Limits Range 2 Span Range 3 Span Range 4 Span Range 5 Span Units min max min max min max min max inH O 2.5 250 10 1000 83.040 8304 553.60 55360 2 inHg 0.18389 18.389 0.73559 73.559 6.1081 610.81 40.720 4072.04 ftH O 0.20833 20.8333 0.83333 83.3333 6.9198 691.997 46.13 4613.31 2 mmH O 63.553 6355 254 25421 2110.95 211095 14073 1407301 2 mmHg 4.67082 467.082 18.6833 1868.33 155.145 15514.5 1034.3 103430 psi 0.0902 9.03183 0.36127 36.127 3 300 20 2000 bar 0.00623 0.62272 0.02491 2.491 0.20684 20.6843 1.37895 137.895 mbar 6.22723 622.723 24.9089 2490.89 206.843 20684.3 1378.95 137895 2 g/cm 6.33875 633.875 25.355 2535.45 210.547 21054.7 1406.14 140614 2 kg/cm 0.00635 0.635 0.0254 2.54 0.21092 21.0921 1.40614 140.614 Pa 622.723 62160.6 2490.89 249089 20684.3 2068430 137895 13789500 kPa 0.62272 62.2723 2.49089 249.089 20.6843 2068.43 137.895 13789.5 torr 4.67082 467.082 18.6833 1868.33 155.145 15514.5 1034.3 103430 atm 0.00615 0.61460 0.02458 2.458 0.20414 20.4138 1.36092 136.092 When using a HART communicator, ±5% adjustment is allowed on the sensor limit to allow for unit conversions. 39 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 3051T Gage and Absolute Pressure Transmitter Range Limits Range 1 Span Range 2 Span Range 3 Span Range 4 Span Range 5 Span Units min max min max min max min max min max 8.30397 831.889 41.5198 4159.45 221.439 22143.9 1107.2 110720 55360 276799 inH O 2 inHg 0.61081 61.0807 3.05403 305.403 16.2882 1628.82 81.441 8144.098 4072.04 20360.2 ftH O 0.69199 69.3241 3.45998 345.998 18.4533 1845.33 92.2663 9226.63 4613.31 23066.6 2 mmH O 211.10 21130 1054.60 105460.3 5634.66 563466 28146.1 2814613 1407301 7036507 2 mmHg 15.5145 1551.45 77.5723 7757.23 413.72 41372 2068.6 206860.0 103430 517151 psi 0.3 30 1.5 150 8 800 40 4000 2000 10000 bar 0.02068 3.06843 0.10342 10.3421 0.55158 55.1581 2.75791 275.7905 137.895 689.476 mbar 20.6843 2068.43 103.421 10342.11 551.581 55158.1 2757.91 275790.5 137895 689476 2 g/cm 21.0921 2109.21 105.461 10546.1 561.459 56145.9 2807.31 280730.6 140614 703067 2 kg/cm 0.02109 2.10921 0.10546 10.5461 0.56246 56.2456 2.81228 281.228 140.614 701.82 68947600 Pa 2068.43 206843 10342.1 1034212 55158.1 5515811 275791 27579054 13789500 kPa 2.06843 206.843 10.3421 1034.21 55.1581 5515.81 275.791 27579.05 13789.5 68947.6 torr 15.5145 1551.45 77.5726 7757.26 413.721 413721 2068.6 206859.7 103430 517151 atm 0.02041 2.04138 0.10207 10.2069 0.54437 54.4368 2.72184 272.1841 136.092 680.46 When using a HART communicator, ±5% adjustment is allowed on the sensor limit to allow for unit conversions. 3051C Absolute Pressure Transmitter Range Limits Range 1 Span Range 2 Span Range 3 Span Range 4 Span Units min max min max min max min max inH O 8.30397 831.889 41.5198 4151.98 221.439 22143.9 1107.2 110720 2 inHg 0.61081 61.0807 3.05403 305.403 16.2882 1628.82 81.441 8144.098 ftH O 0.69199 69.3241 3.45998 345.998 18.4533 1845.33 92.2663 9226.63 2 mmH O 211.10 21130 6.35308 635.308 5634.66 563466 28146.1 2814613 2 mmHg 15.5145 1551.45 1055.47 105547 413.72 41372 2068.6 206860.0 psi 0.3 30 1.5 150 8 800 40 4000 bar 0.02068 2.06843 0.10342 10.342 0.55158 55.1581 2.75791 275.7905 mbar 20.6843 2068.43 103.421 10342.1 551.581 55158.1 2757.91 275790.5 2 g/cm 21.0921 2109.21 105.27 105.27 561.459 56145.9 2807.31 280730.6 2 kg/cm 0.02109 2.10921 0.10546 10.546 0.56246 56.2456 2.81228 281.228 Pa 2068.43 206843 10342.1 1034210 55158.1 5515811 275791 27579054 kPa 2.06843 206.843 10.3421 1034.21 55.1581 5515.81 275.791 27579.05 torr 15.5145 1551.45 77.5726 7757.26 413.721 413721 2068.6 206859.7 atm 0.02041 2.04138 0.10207 10.207 0.54437 54.4368 2.72184 272.1841 When using a HART communicator, ±5% adjustment is allowed on the sensor limit to allow for unit conversions. 40 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 HART Protocol C1 Option Configuration Data Sheet (1) ★ = Default Value CONFIGURATION DATA SHEET Customer: _____________________________________________ P.O. No.: _____________________________________________ Model No.: _____________________________________________ Line Item: _____________________________________________ SST Tag No.: _________________________________________________________________________________________________ Software Tag: |__|__|__|__|__|__|__|__| OUTPUT INFORMATION: (Software Selectable) 4 mA (1, 0.8 Volts) = ___________________ 0 ★ 20 mA (5, 3.2 Volts) = __________________ Upper Range Limit ★ (2) (3) Pressure Units = □ inH O ★ □ psi ★ □ Pa □ ftH O 2 2 2 □ inHg □ bar □ kPa □ g/cm (5) □ mbar □ Torr □ mmH O □ inH O at 4 °C 2 2 2 (5) □ Atm □ kg/cm □ mmHg □ mmH O at 4 °C 2 Output = □ Linear ★ □ Square Root (For DP transmitters only) (4) Damping = □ 0.00 sec. □ 0.05 sec. □ 0.10 sec. □ 0.20 sec. □ 0.40 sec.★ □ 0.80 sec. □ 1.60 sec. □ 3.20 sec. □ 12.8 sec. □ 25.6 sec. TRANSMITTER INFORMATION: (Software Selectable) (4) Descriptor : |__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|(16 characters) (4) Message : |__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__| (32 characters) (4) Date : □ □/□ □ □/□ □ Day Month Year Local Span and Zero: □Enabled ★ □ Disabled (1) Default values may be different outside the U.S. A. Consult an Emerson Process Management Representative for details. (2) inH20 for CD/CG ranges 1-3 (3) psi for CD/CG range 4 and 5, all CA ranges (4) C1 option required for configuration of this parameter. (5) Not available with low power output. 41 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 LCD display CONFIGURATION (Software Adjustable – M5 or M6 option must be specified in model number) (4) Meter Display Type : □ Eng. Units only □ Alternate Eng. Units &% of Range ★ (5) □ % of Range only □ Alternate Eng. Units & Custom Display (5) □ Custom Display only □ Alternate % of Range & Custom Display Custom Display Configuration: (must be filled out if Custom Display is selected as meter type) Decimal Point Position ★ (fixed)— X X X X X � � � � � indicate decimal point location: Enter Lower Range Value (Decimal point must be in the same position as specified above.) (circle sign) +– □ □ □ □ □ +000.00 ★ � � � � � Enter Upper Range Value (Decimal point must be in the same position as specified above.) (circle sign) +– □ □ □ □ □ +100.00 ★ � � � � � Custom Units—spaces consume A-Z, 0-9, /, , %, blank * %RNGE ★ □ □ □ □ □ Custom Display Transfer Function (Independent of Analog Output) □ Linear ★ □ Square Root HARDWARE SELECTABLE INFORMATION Alarm Option: � High � Low Transmitter Security: � Off � On (5) Note: Specify C4 Option in model structure when ordering NAMUR-compliant alarm and saturation limits. SIGNAL SELECTION: (Software Selectable) � 4–20 mA with simultaneous digital signal based on HART protocol★ (4) � Burst mode of HART digital process variable Burst mode output options: � Primary variable in engineering units � Primary variable in percent of range � All dynamic variables in engineering units and the primary variable mA value (4)(6) (7) � Multidrop Communication Choose transmitter address (1-15): _______________ (4) C1 option required for configuration of this parameter. (5) Not available with low power output. (6) This option fixes the transmitter analog output at 4mA. (7) Default address is 1 if multidrop communication is selected. 42 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 43 Product Data Sheet 00813-0100-4001, Rev HA March 2008 Rosemount 3051 Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount, Annubar, ProPlate, and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. Instrument Toolkit is a registered trademark of Emerson Process Management. Complete Point Solutions, Coplanar and Multivariable are trademarks of Rosemount Inc. HART is a registered trademark of the HART Communications Foundation. Hastelloy is a registered trademark of Haynes international, Inc.. Monel is a registered trademark of the Special Metals Corporation group of Companies. Syltherm 800, Dow Corning, and D.C. are registered trademarks of Dow Corning Co. Neobee M-20 is a registered trademark of Stephan Chemical Co. The 3-A symbol is a registered trademark of the 3-A Sanitary Standards Symbol Council. FOUNDATION fieldbus is a registered trademark of the Fieldbus Foundation. Fluorinert is a registered trademark of 3M Company. All other marks are the property of their respective owners. Rosemount Model 3051 Smart Pressure Transmitters may be protected by one or more of the following U.S. Patent Nos. 4,370,890; 4,466,290; 4,612,812; 4,791,352; 4,798,089; 4,818,994; 4,833,922; 4,866,435; 4,926,340; 4,988,990; and 5,028,746. Mexico Patentado No. 154,961. May depend on model. Other foreign patents issued and pending. Emerson Process Management Rosemount Inc. Emerson Process Management Emerson Process Management Asia 8200 Market Boulevard Heath Place Pacific Private Limited Chanhassen, MN 55317 USA Bognor Regis 1 Pandan Crescent T (U.S.) 1 800 999 9307 West Sussex PO22 9SH Singapore 128461 T (International) (952) 906 8888 England T (65) 6777 8211 F (952) 949 7001 T 44 (0) 1243 863121 F (65) 6777 0947 F 44 (0) 1243 867554 Enquiries@AP.EmersonProcess.com www.rosemount.com ¢00813-0100-4001;¤ © 2008 Rosemount Inc. All rights reserved.

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 3051TG3A2A21AB4 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

SCREW CAP/ELECTRONIC COVER

product

Rosemount 304 Series Conventional Manifold Valves, Traditional Style

product

Rosemount 305 Series Integral Manifold Valve, Coplanar Style

product

Rosemount Series 306 Inline Manifold

product

Rosemount 333U HART Tri-Loop. HART to Analog Signal Converter | High Alarm | 42.4V DC | 4-20mA Outpu...