Specifications

Ambient Temperature Effect

Expressed as a total effect per 50 °F (28 °C) Total effect includes zero and span effects. ± (0.15% URL + 0.15% of span) from –40 °F to 185 °F (-40 °C to 85 °C)

Burst Pressure

11,000 psi for all ranges

Current Draw

Output Code N less than or equal to 3 mA without LCD display.

Humidity Limits

0–100% relative humidity

Mounting Position Effect

Zero shift of up to 1.2 inH2O (0.30 kPa), which can be calibrated out. No span effect.

Overpressure Limits

Range 1: 120 psig max; All other ranges: two times the URL

Power Supply

External power supply required. Transmitter opera

Power Supply Effect

Less than 0.01% of calibrated span per volt

Reference Accuracy

±0.10% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability; ±0.075% of calibrated span (high accuracy option)

Service

Liquid, gas, and vapor applications

Stability

±0.10% of URL for 12 months

Temperature

–40 to 185 °F (–40 to 85 °C)

Time Response

Time Constant: 200 milliseconds; Dead time:

Turn-on Time

2.0 seconds, no warm-up required

Vibration Effect

Less than ±0.1% of URL when subjected to vibration of: peak to peak constant displacement of 4 mm (5–15 Hz) and constant acceleration of 2 g (15–150 Hz) and 1 g (150–2000 Hz).

Volumetric Displacement

Less than 0.00042 cm

Features

Datasheet

pdf file

2088G2S22A1-1513424616.pdf

5727 KiB

Extracted Text

Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter • Performance of 0.075% with High Accuracy option • Lightweight, compact design for cost effective installation ® • Protocols available include 4-20 mA HART and 1-5 Vdc HART Low Power • Absolute and gage pressure ranges up to 4000 psi (276 bar) • Rangeability of 20:1 Contents Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3 Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5 Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9 www.rosemount.com Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.075% with high accuracy 4-20 mA HART and 1-5Vdc HART Low Power option Protocols Available The Rosemount 2088 utilizes our reliable solid-state, The 2088 utilizes the advantages of HART polysilicon pressure sensor with a choice of either communication, enabling quick and easy reranging, 316L or Alloy C-276 isolating diaphragms. This calibration and troubleshooting. It also features a design has many benefits, including a reference fully configurable LCD that displays pressure and accuracy of 0.075% and a stability of 0.10% for 12 diagnostic information. The information displayed is months. directly from the microprocessor which accounts for its accuracy and reliability. Lightweight, Compact Design Absolute or gage pressure ranges up to 4000 psi Its lightweight, compact design allows the 2088 to be (276 bar) and 20:1 rangedown directly connected to a process – providing a quick, easy and cost effective installation. A variety of The 2088 is available in either gauge or absolute process connections are available, including multiple pressure in ranges to 4,000 psi (276 bar). Higher threaded connections, our full line of manifolds and turndown means lower inventories by allowing you to remote diaphragm seals that provide solutions for measure pressures from 1.5 psi (103 mbar) to virtually any application. 4000 psi (276 bar) with only four transmitter ranges. Rosemount Pressure Solutions ® Rosemount 3051S Series of Instrumentation Flowmeters and Rosemount 3051SFA Annubar Highest performing scalable pressure, flow and level Rosemount 485 Annubar Flowmeter Series measurement solutions drive better plant efficiency and The state-of-the-art, fifth generation Rosemount 485 more productivity. Innovative features include wireless, Annubar combined with the Rosemount MultiVariable advanced diagnostics, and multivariable technologies. transmitter technology creates an accurate, repeatable and dependable insertion-type flowmeter. Rosemount 305, 306 and 304 Manifolds Rosemount 3051SFC Compact Orifice Flowmeters and Factory-assembled, calibrated and seal-tested Rosemount 405 Compact Orifice Flowmeter Series transmitter-to-manifold assemblies reduce installation costs. Compact Orifice Flowmeters can be installed between existing flanges, up to a Class 600 (PN100) rating. A Rosemount 1199 Diaphragm Seals conditioning orifice plate version offers installation in tight fit Provides reliable, remote measurements of process applications requiring only two diameters of straight run pressure and protects the transmitter from hot, corrosive, upstream after a flow disturbance. or viscous fluids. Orifice Plate Primary Element Systems: Rosemount Rosemount 3051SFP Integral Orifice Flowmeters and 1495 and 1595 Orifice Plates, 1496 Flange Unions and Rosemount 1195 Integral Orifice Flowmeter Series 1497 Meter Sections These integral orifice flowmeters eliminate the inaccuracies A comprehensive offering of orifice plates, flange unions that become more pronounced in small orifice line and meter sections that are easy to specify and order. The installations. The completely assembled, ready to install flowmeters reduce cost and simplify installation. 1595 Conditioning Orifice provides superior performance in tight fit applications. 2 Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 Specifications Ranges Performance Specifications (1) (Zero-based spans, reference conditions, silicone oil fill, and 316L Minimum Upper Lower Lower SST isolating diaphragm.) Range Span (URL) (LRL) (LRL) (Gage) 1 1.5 psi 30 psi 0 psia –14.7 psig Reference Accuracy (0,103 bar) (2,1 bar) (0 bar) (–1,01 bar) • ±0.10% of calibrated span. Includes combined effects of 2 8 psi 150 psi 0 psia –14.7 psig linearity, hysteresis, and repeatability (0,55 bar) (10,3 bar) (0 bar) (–1,01 bar) • ±0.075% of calibrated span (high accuracy option) 3 40 psi 800 psi 0 psia –14.7 psig (2,76 bar) (55,2 bar) (0 bar) (–1,01 bar) Ambient Temperature Effect 4 200 psi 4000 psi 0 psia –14.7 psig Expressed as a total effect per 50 °F (28 °C) (13,8 bar) (275,8 bar) (0 bar) (–1,01 bar) Total effect includes zero and span effects. (1) Assumes atmospheric pressure of 14.7 psig. ± (0.15% URL + 0.15% of span) from –40 °F to 185 °F (-40 °C to 85 °C) Output Code S: 4–20 mA dc Stability Code N: 1-5 volt dc, low power ±0.10% of URL for 12 months (Outputs are directly proportional to the input pressure) Vibration Effect Rangedown Less than ±0.1% of URL when subjected to vibration of: peak to 20 to 1 peak constant displacement of 4 mm (5–15 Hz) and constant acceleration of 2 g (15–150 Hz) and 1 g (150–2000 Hz). Load Limitations Reverse polarity protection is standard. Maximum loop resistance Power Supply Effect is determined by the power supply voltage as described by the Less than 0.01% of calibrated span per volt following equations: Mounting Position Effect Max. Loop Resistance = 43.5 (Power Supply Voltage – 10.5) Zero shift of up to 1.2 inH O (0.30 kPa), which can be calibrated 2 out. No span effect. RFI Effect Operating Less than ±0.25% of upper range limit from Region 20–1000 MHz at 30 V/m with leads in conduit. Less than ±0.25% of upper range limit from 20-1000 MHz at 10 V/m with unshielded twisted pair (no conduit). Transient Protection Limits Power Supply Output Code S (dc Volts) Communication requires a minimum loop resistance of 250 ohms. IEEE 587 Category B 6 kV Crest (1.2 � 50 �s) (1) For hazardous location approvals, power supply must not exceed 36 V. 3 kA Crest (8 � 20 �s) (2) For CENELEC Ex ia approval, the power supply must not exceed 30 V. 6 kV Crest (0.5 �s by 100 kHz) IEEE 472 Power Supply SWC 2.5 kV Crest,1 MHz waveform External power supply required. Transmitter operates on 10.5–36 V dc with no load (6–14V for Low Power). Reverse General Specifications polarity protection is standard. Tested to IEC 801-3 Current Draw Functional Specifications Output Code N:  3 mA without LCD display. Service Overpressure Limits Liquid, gas, and vapor applications Range 1: 120 psig max All other ranges: two times the URL 3 Load (ohms) Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 Burst Pressure Standard Operation 11,000 psi for all ranges Output Code Linear Output Fail High Fail Low Zero Elevation and Suppression S 3.9  I  20.8 I 21.75 mA I  3.75 mA Zero can be suppressed between atmosphere for gage N 0.97  V  5.2 V 5.4 V V  0.95V transmitters or 0 psia for absolute transmitters and upper range N with Code C2 0.78  V  3.44 V 4.0 V V  0.77 V limit, provided the calibrated span is equal to or greater than the minimum span, and the upper range value does not exceed the NAMUR-Compliant upper range limit. Operation Linear Output Fail High Fail Low Output Code S 3.8  I  20.5 I 22.5 mA I  3.6 mA Time Response Time Constant: 200 milliseconds Physical Specifications Dead time: < 0.1 s Update rate: 20 times per second minimum Electrical Connection Temperature Limits 1 /2–14 NPT, M20 � 1.5 (CM20), PG 13.5, or 1 1 Ambient: G /2 female (PF /2 female) conduit entry –40 to 185 °F (–40 to 85 °C) (1) –4 to 175 °F (–20 to 80 °C) with LCD display Process Connection 1 1 1 1 /2–14 NPT female, DIN 16288 G /2 male, RC /2 female (PT /2 (1) LCD display may not be readable and LCD updates will be slower at temperatures below -4 °F (-20 °C). female), M20 � 1.5 (CM20) male Storage: Process Wetted Parts –50 to 230 °F (–46 to 110 °C) –40 to 185 °F (–40 to 85 °C) with LCD display Isolating Diaphragm Process: 316L stainless steel or Alloy C-276 (1) Silicone fill sensor: –40 to 250 °F (–40 to 121 °C) (1) Process Connector Inert fill sensor: –22 to 250 °F (–30 to 121 °C) 316L stainless steel CF-3M (Cast version of 316L SST, Process temperatures above 185 °F (85 °C) require derating material per ASTM_A743) or Alloy C-276 the ambient limits by a 1.5:1 ratio. For example, for process temperature of 195 °F (91 °C), new ambient temperature limit is equal to 170 °F (77 °C). This can be determined as follows: Non-wetted Parts (195 °F - 185 °F) x 1.5 = 15 °F, 185 °F - 15 °F = 170 °F Electronics Housing (1) 250 °F (140 °C) limit in vacuum service; 130 °F (54 °C) for Low-copper aluminum, NEMA 4X, IP65, IP67,CSA enclosure pressures below 0.5 psia. Type 4X Paint Polyurethane Humidity Limits 0–100% relative humidity Cover O-rings Buna-N Volumetric Displacement 3 Less than 0.00042 cm Fill Fluid Silicone or inert fill Turn-on Time Weight 2.0 seconds, no warm-up required Output Code S and N: Approximately 2.44 lb (1.11 kg) Transmitter Security Tagging Activating the transmitter security function prevents changes to the transmitter configuration, including local zero and span The transmitter is tagged, at no charge, in accordance with adjustments. Security is activated by an internal switch. customer requirements. All tags are stainless steel. The standard tag is permanently attached to the transmitter. Tag character 1 Failure Mode height is /8 in. (0.318 cm). A wired tag is available upon request. If self-diagnostics detect a sensor or microprocessor failure, the Accessory Block and Bleed Valve (S5 Option) analog signal is driven either high or low to alert the user. High or low failure mode is user-selectable with a jumper on the The Rosemount 306 Integral Manifold is pre-assembled to transmitter. The values to which the transmitter drives its output in transmitter and leak checked. failure mode depend on whether it is factory-configured to standard or NAMUR-compliant operation. The values for each are as follows: 4 Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 Product Certifications Canadian Standards Association (CSA) Approved Manufacturing Locations All CSA hazardous approved transmitters are certified per Rosemount Inc. — Chanhassen, Minnesota, USA ANSI/ISA 12.27.01-2003. Emerson Process Management GmbH & Co. — Wessling, C6 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Germany Dust-Ignition-Proof for Class II, Division 1, Groups E, F, G, Emerson Process Management Asia Pacific Class III, indoor and outdoor hazardous locations. CSA Private Limited — Singapore enclosure Type 4X; factory sealed. Suitable for Class I, Beijing Rosemount Far East Instrument Co., LTD — Beijing, China Division 2, Groups A, B, C, and D. Intrinsically Safe for Class I, Division 1, Groups A, B, C, and European Union Directive Information D. Temp. Code T3C. Intrinsically safe when connected with The EC declaration of conformity for all applicable European approved barriers in accordance with Rosemount drawing directives for this product can be found at www.rosemount.com. A 02088-1024. hard copy may be obtained by contacting our local sales office. For input parameters see control drawing 02088-1024. ATEX Directive (94/9/EC) European Certifications Emerson Process Management complies with the ATEX I1 ATEX Intrinsically Safe Directive. Certificate No.: BAS00ATEX1166X II 1 G Ex ia IIC T5 (T = –55 to 40 °C) amb European Pressure Equipment Directive (PED) (97/23/EC) Ex ia IIC T4 (T = –55 to 70°C) amb 2088/2090 Pressure Transmitters 1180 — Sound Engineering Practice TABLE 1. Input Parameters Electro Magnetic Compatibility (EMC) (2004/108/EC) Loop/Power All 2088/2090 Pressure Transmitter: U = 30 V dc i EN 61326-1:1997 with Amendments A1, A2, and A3 I = 200 mA i P = 0.9 W i C = 0.012 �F i Hazardous Locations Certifications Special Conditions For Safe Use (x): North American Certifications When the optional transient protection terminal block is installed, the apparatus is not capable of withstanding a Ordinary Location Certification for Factory Mutual 500V rms test to case. This must be taken into account on any installation in which it is used, for example by assuring As standard, the transmitter has been examined and tested that the supply to the apparatus is galvanically isolated. to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a N1 ATEX Type n nationally recognized testing laboratory (NRTL) as Certification No.: BAS00ATEX3167X II 3 G accredited by the Federal Occupational Safety and Health Ex nA nL IIC T5 (T = -40 °C to 70 °C) a Administration (OSHA). U = 50 V dc max i Factory Mutual (FM) Approvals Special Conditions For Safe Use (x): When the optional transient protection terminal block is E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. installed, the apparatus is not capable of withstanding a 500 Dust-Ignition-Proof for Class II, Division 1, Groups E, F, G, V r.m.s. test to case. This must be taken into account on any Class III, Division 1, indoor and outdoor (Type 4X) hazardous installation in which it is used, for example, by assuring that locations; factory sealed. Temperature Class T5 Ta = 85 °C. the supply to the apparatus is galvanically isolated. I5 Intrinsically safe for use in Class I, Division 1, Groups A, B, C, D; Class II, Division 1, Groups E, F, and G; and Class III, Division 1 when connected in accordance with Rosemount drawing 02088-1018. Non-incendive for Class I, Division 2, Groups A, B, C, and D. For input parameters see control drawing 02088-1018. Temperature Class T4 Ta = 85 °C; indoor and outdoor (NEMA 4X) hazardous locations. 5 Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 ND ATEX Combustible Dust Australian Certifications Certificate No.: BAS01ATEX1427X II 1 D I7 SAA Intrinsic Safety Ex tD A20 T105°C (T = -20°C to 85°C) amb Certification No.: AUS Ex 1249X IP66 Ex ia IIC T4 (T = 70 °C) amb 1180 Ex ia IIC T5 (T = 40 °C) amb Vmax = 36 V dc Max IP66 I = 24 mA i When connected per Rosemount drawing 03031-1026 Special Conditions For Safe Use (x): TABLE 2. Input Parameters 1. The user must ensure that the maximum rated voltage and current (36 volts, 24 mA, D.C.) are not exceeded. All Loop/Power connections to other apparatus or associated apparatus U = 30 V max shall have control over this voltage and current equivalent I = 200 mA to a category “ib” circuit according to EN50020. max 2. Cable entries must be used which maintain the ingress P = 0.9 W max protection of the enclosure to at least IP66. C = 0.01 �F i 3. Unused cable entries must be filled with suitable blanking L = 10 �H i plugs which maintain the ingress protection of the Special Conditions For Safe Use (X): enclosure to at least IP66. Observe barrier/entity parameters during installation. A 4. Cable entries and blanking plugs must be suitable for the passive current limited power source must be used. The ambient range of the apparatus and capable of power source must be such that Po (Uo * Io)/4. For withstanding a 7J impact test. modules using transient protection in the terminal assembly 5. The 2088/2090 sensor module must be securely screwed (T1 transient protection models), the apparatus enclosure is in place to maintain the ingress protection of the to be electrically bonded to the protective earth. The enclosure. conductor used for the connection shall be equivalent to a ED ATEX Flameproof 2 copper conductor of 4mm minimum cross-sectional area. Certification No.: KEMA97ATEX2378 II 1/2 G N7 SAA Type n (Non-Sparking) Ex d IIC T6 (T = -40 °C to 40°C) a Certificate No.: AUS Ex 1249X T4 (T = -40 °C to 80 °C) a Ex n IIC T4 (T = 70 °C) amb 1180 Ex n IIC T5 (T = 40 °C) amb Vmax = 36 (with Output Code S) IP66 Vmax = 14 (with Output Code N) Special Conditions For Safe Use (X): Japanese Certifications Where the equipment is installed such that there is an E4 TIIS Flameproof unused conduit entry, it must be sealed with a suitable blanking plug to maintain the IP66 degree of protection. Any Ex d IIC T6 (T = 85 °C) amb blanking plug used with the equipment shall be of a type Certificate Description which requires the use of a tool to effect its removal. Voltage TC15879 2088 with SST wetted parts source shall not exceed 60V ac or 75V dc. (with display) E7 IECEx Flameproof (Explosion-Proof) TC15877 2088 with Alloy C-276 wetted parts IECEx Certificate number: IECEx KEM 06.0021X (with display) Ex d IIC T6(T = -20°C to 40°C) amb TC15876 2088 with Alloy C-276 wetted parts Ex d IIC T4(T = -20°C to 80°C) amb (no display) Vmax = 55Vdc TC15875 2088 with SST wetted parts Ii = 23mA (no display) TC15874 2088 with Alloy C-276 wetted parts (with display) TC15873 2088 with Alloy C-276 wetted parts (no display) TC15872 2088 with SST wetted parts (with display) TC15871 2088 with SST wetted parts (no display) 6 Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 NK IECEx Dust Ignition Proof Combinations of Certifications IECEx Certificate number: IECEx KEM 06.0021X Stainless steel certification tag is provided when optional approval Ex tD A22 IP66 T90°C(T = -20°C to 80°C) amb is specified. Once a device labeled with multiple approval types is Vmax = 55Vdc installed, it should not be reinstalled using any other approval Ii = 23mA types. Permanently mark the approval label to distinguish it from Special Conditions For Safe Use (x): unused approval types. KB Combination of K5 and C6 1. The device contains a thin wall diaphragm. Installation, maintenance, and use shall take into account the KH Combination of K5, I1, and ED environmental conditions to which the diaphragm will be K5 Combination of E5 and I5 subjected. The manufacturer’s instructions for installation K6 Combination of C6, I1, and ED and maintenance shall be followed in detail to assure safety K7 Combination of I7, N7, E7, and NK during its expected lifetime. K1 Combination of I1, N1, ED, and ND 2. Cable entries must be used which maintain the ingress protection of the enclosure to at least IP 66. 3. Unused cable entries must be used which maintain the ingress protection of the enclosure to at least IP 66. 4. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7J impact. 5. The 2088/2090 sensor module must be securely screwed in place to maintain the ingress protection of the enclosure Brazil Certifications I2 INMETRO Intrinsic Safety Certification No.: CEPEL-Ex-063/97-1X BR-Ex ia IIC T5/T4 E2 INMETRO Flameproof Certification No.: CEPEL-Ex-076/97-1 BR-Ex d IIC T6/T5 7 Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 Dimensional Drawings Rosemount 2088 0.75 (20) 5.0 (127) Certifications Clearance Optional Tag 4.3 (110) Max. for Cover 3.9 (99) Display Cover Removal † 2 � ½–14 NPT Conduit Connection 4.7 Transmitter Terminal (120) Circuitry Connections 5.75 (146) Typical 2 �¼–20 UNC-2B Mounting Holes † 1 1 M20 � 1.5 Female (CM20), PG 13.5, and G /2 Female (PF /2 Female) also available as options. ½–14 NPT Female Process Connection (See Ordering Table for other options.) Mounting Configurations with Optional Mounting Brackets Pipe Mounting Panel Mounting 5.0 (127) 3.9 (99) 4.3 (110) 4.0 (102) 5.3 6.2 (135) 3.8 (157) 2.8 (97) (71) 3.1 6.3 (159) 3.0 (80) (78) 4.8 (122) 2-inch U-Bolt for pipe mounting 7.0 (178) (clamp shown) 2.8 (71) 5 /16× 1½ Bolts for panel mounting (not supplied) 1 1 1 1 /4× 1 /4 Bolts /4× 1 /4 Bolts for transmitter mounting for transmitter mounting (not supplied) (not supplied) 1.3 (33) 1.3 (33) Dimensions are in inches (millimeters). 8 Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 Ordering Information TABLE 3. Rosemount 2088 Pressure Transmitter Ordering Information ★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery. __The Expanded offering is manufactured after receipt of order and is subject to additional delivery lead time. Model Product description 2088 Pressure Transmitter Code Measurement Type Standard Standard A Absolute ★ G Gage ★ Code Pressure Ranges Standard Standard 2088G 2088A 1 -14.7 to 30 psi /(-1,01 to 2,1 bar) 0 to 30 psi (0 to 2,1 bar) ★ 2 -14.7 to 150 psi (-1,01 to 10,3 bar) 0 to 150 psi (0 to 10,3 bar) ★ 3 -14.7 to 800 psi (-1,01 to 55,2 bar) 0 to 800 psi (0 to 55,2 bar) ★ 4 -14.7 to 4,000 psi(-1,01 to 275,8 bar) 0 to 4,000 psi (0 to 275,8 bar) ★ Code Transmitter Output Standard Standard ® S 4–20 mA dc/Digital HART Protocol ★ N 1-5 V dc Low Power/ Digital HART protocol ★ Code Materials of Construction Standard Standard Process connection Isolating diaphragm Fill Fluid (1) 22 316L SST 316L SST Silicone ★ (1) 33 Alloy C-276 Alloy C-276 Silicone ★ Expanded (1) 2B 316L SST 316L SST Inert Code Process Connection Standard Standard A ½–14 NPT Female ★ (2) B DIN 16288 G ½ Male ★ (2)(3) D M20 � 1.5 Male (CM20 Male) ★ Expanded (2)(3) C RC ½ Female (PT ½ Female) Code Conduit Entry Standard Standard 1 ½–14 NPT ★ (2) 2 M20 � 1.5 Female (CM20) ★ Expanded (2) 4 G ½ Female (PF ½ Female) Options (Include with selected model number) Diaphragm seal assemblies Standard Standard (4)(5) S1 Assemble to one Rosemount 1199 diaphragm seal ★ 9 Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 TABLE 3. Rosemount 2088 Pressure Transmitter Ordering Information ★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery. __The Expanded offering is manufactured after receipt of order and is subject to additional delivery lead time. Digital Display Standard Standard M5 LCD display ★ M7 LCD display, special configuration ★ Mounting brackets Standard Standard B4 SST mounting bracket with SST Bolts ★ Product Certifications Standard Standard C6 CSA Explosion-Proof, Intrinsically Safe, and Non-Incendive ★ (2)(6) E4 TIIS Flameproof ★ E5 FM Explosion-Proof, Dust Ignition-proof ★ E7 IECEx Flameproof ★ ED ATEX Flameproof ★ (2) I1 ATEX Intrinsic Safety ★ I5 FM Intrinsically safe, Division 2 ★ I7 SAA Intrinsic Safety ★ K5 FM Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★ (2) K6 CSA Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★ KB FM and CSA Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2 ★ (2) KH FM Approvals and ATEX Explosion-Proof and Intrinsically Safe ★ (2) N1 ATEX Type n ★ N7 SAA Type n ★ (2) ND ATEX Dust ★ NK IECEx Dust ★ K7 SAA Flameproof, Dust Ignition-proof, Intrinsic Safety, Type n ★ K1 ATEX Flameproof, Intrinsic Safety, Type n, Dust ★ I2 INMETRO Intrinsic Safety ★ E2 INMETRO Flameproof ★ Pressure Testing Expanded P1 Hydrostatic testing Terminal Blocks Standard Standard T1 Transient protection ★ Special Cleaning Expanded P2 Cleaning for special service Calibration Certificate Standard Standard Q4 Calibration certificate ★ Quality Calibration Certificate Traceability Certification Standard Standard Q8 Material Traceability Certification per EN 10204 3.1B ★ Digital Signal Standard Standard (2) C4 NAMUR alarm and saturation levels, high alarm ★ (2) CN NAMUR alarm and saturation levels, low alarm ★ Configuration Standard Standard C9 Software configuration ★ 10 Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 TABLE 3. Rosemount 2088 Pressure Transmitter Ordering Information ★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery. __The Expanded offering is manufactured after receipt of order and is subject to additional delivery lead time. Manifold Assemblies Standard Standard (4)(5) S5 Assemble to Rosemount 306 integral manifold ★ Calibration Accuracy Standard Standard (7) P8 0.075% accuracy to 10:1 turndown ★ Water Approval Standard Standard (8) DW NSF drinking water approval ★ Low Output for Low Power Expanded C2 0.8 - 3.2 V dc output with HART protocol, Output code N only. Surface Finish Standard Standard Q16 Surface finish certification for sanitary remote seals ★ Toolkit Total System Performance Reports Standard Standard QZ Remote Seal System Performance Calculation Report ★ Typical Model Number: 2088 G 2 S 22 A 1 B4 M5 (1) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments. (2) Not available with low-power Output code N. (3) Not available with Alloy C-276, Materials of Construction code 33. 1 (4) Use /2 - 14 NPT Female Process Connection code A. (5) “Assemble-to” items are specified separately and require a completed model number. (6) Only available with Conduit Thread code 4. (7) Available with Output code S, stainless steel isolators, and silicone fill. (8) Requires Materials of Construction code 22 with Process Connection code A. 11 Product Data Sheet 00813-0100-4690, Rev KB April 2010 Rosemount 2088 Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount, the Rosemount logotype, Annubar, ProPlate and Mass ProPlate are registered trademarks of Rosemount Inc. HART is a registered trademark of the HART Communications Foundation. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. All other marks are the property of their respective owners. © 2010 Rosemount, Inc. All rights reserved. Emerson Process Management Asia Pacific Emerson Process Management Emerson Process Management Emerson FZE Pte Ltd Rosemount Measurement Blegistrasse 23 P.O. Box 17033 8200 Market Boulevard Jebel Ali Free Zone 1 Pandan Crescent P.O. Box 1046 Chanhassen MN 55317 USA Dubai UAE Singapore 128461 CH 6341 Baar Tel (USA) 1 800 999 9307 Tel +65 6777 8211 Switzerland Tel +971 4 811 8100 Tel (International) +1 952 906 8888 Fax +971 4 886 5465 Fax +65 6777 0947 Tel +41 (0) 41 768 6111 Fax +1 952 949 7001 Service Support Hotline : +65 6770 8711 Fax +41 (0) 41 768 6300 Email : Enquiries@AP.EmersonProcess.com 00813-0100-4690 Rev KB, 4/10

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 2088G2S22A1 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

PH METER

MOUNTING BRKT

ANALYZER PH/ORP CONTROLLER 115/230V

product

ROSEMOUNT-268AD9E-Terminal Smart Family with Hart Communicator