Elite.Parts chervon right Manufacturers chervon right R chervon right ROHDE & SCHWARZ chervon right R&SFSU
About product Features Datasheet FAQ

ROHDE & SCHWARZ R&SFSU

Image of ROHDE & SCHWARZ R&SFSU

Description

Rohde & Schwarz R&SFSU Spectrum Analyzer

Part Number

R&SFSU

Price

Request Quote

Manufacturer

ROHDE & SCHWARZ

Lead Time

Request Quote

Category

PRODUCTS - R

Features

Datasheet

pdf file

RohdeSchwarz-RSFSU-Analyzer-datasheet1-2135714585.pdf

2050 KiB

Extracted Text

R&S®FSU Spectrum Analyzer Specifications FSU_dat-sw_en_0758-0016-22_v1601_cover.indd 1 22.05.2012 18:35:42 Test & Measurement Data Sheet | 16.01 Version 16.01, May 2012 CONTENTS Specifications .................................................................................................................................................................. 3 Frequency ........................................................................................................................................................................ 3 Sweep ............................................................................................................................................................................... 4 Resolution bandwidths ................................................................................................................................................... 4 Level ................................................................................................................................................................................. 5 I/Q data ............................................................................................................................................................................. 9 Audio demodulation ....................................................................................................................................................... 9 Trigger functions .......................................................................................................................................................... 10 Inputs and outputs (front panel) .................................................................................................................................. 10 Inputs and outputs (rear panel) ................................................................................................................................... 11 General specifications .................................................................................................................................................. 12 ® ® ® R&S FSU-B9 tracking generator, R&S FSU-B12 attenuator for tracking generator (not available for R&S FSU67) .......................... 13 ® ® R&S FSU-B21 LO/IF ports for external mixers (for R&S FSU26/43/46/50/67 only) ............................................................................ 15 ® ® ® R&S FSU-B23 RF preamplifier (for R&S FSU26 only, requires R&S FSU-B25 option) ..................................................................... 16 ® ® R&S FSU-B24 preamplifier (for R&S FSU26/43/46/50 only) ............................................................................................................... 17 ® ® R&S FSU-B25 electronic attenuator and low-noise preamplifier, R&S FSU-B85 extended specifications for low-noise preamplifier 19 ® R&S FSU-B27 broadband FM demodulator output .............................................................................................................................. 20 Ordering information .................................................................................................................................................... 21 Options .......................................................................................................................................................................... 22 Recommended extras ................................................................................................................................................... 23 ® 2 Rohde & Schwarz R&S FSU Spectrum Analyzer Version 16.01, May 2012 Specifications Specifications apply under the following conditions: 30 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to, and all internal automatic adjustments performed. Data without tolerances: typical values only. Data designated "nominal" applies to design parameters and is not tested. Frequency ® Frequency range R&S FSU3: DC coupled 20 Hz to 3.6 GHz AC coupled 1 MHz to 3.6 GHz ® R&S FSU8: DC coupled 20 Hz to 8 GHz AC coupled 1 MHz to 8 GHz ® R&S FSU26: DC coupled 20 Hz to 26.5 GHz AC coupled 10 MHz to 26.5 GHz ® R&S FSU43: DC coupled 20 Hz to 43 GHz ® R&S FSU46: DC coupled 20 Hz to 46 GHz ® R&S FSU50: DC coupled 20 Hz to 50 GHz ® R&S FSU67: DC coupled 20 Hz to 67 GHz Frequency resolution 0.01 Hz Reference frequency, internal, nominal standard OCXO –9 Aging per day after 30 days of continuous operation 1 × 10 –7 Aging per year after 30 days of continuous operation 1 × 10 –8 Temperature drift +5 °C to +45 °C 8 × 10 –7 Total error per year 1.8 × 10 ® Reference frequency, internal, nominal R&S FSU-B4 option –10 Aging per day after 30 days of continuous operation 2 × 10 –8 Aging per year after 30 days of continuous operation 3 × 10 –9 Temperature drift +5 °C to +45 °C 1 × 10 –8 Total error per year 5 × 10 External reference frequency 1 MHz to 20 MHz, 1 Hz steps Frequency display with marker or frequency counter Marker resolution 1 Hz Uncertainty ±(marker frequency × reference uncertainty + 10 % × resolution bandwidth + ½ (span/(sweep points –1)) + 1 Hz) Marker tuning frequency stepsize default span/624 marker stepsize = sweep points span/(sweep points – 1) Frequency counter resolution selectable 0.1 Hz to 10 kHz Count accuracy S/N > 25 dB ±(frequency × reference error + ½ (last digit)) Display range for frequency axis 0 Hz, 10 Hz to max. frequency Resolution 0.1 Hz Max. span deviation 1 % Spectral purity, SSB phase noise (1 Hz) f = 640 MHz Residual FM RBW 10 kHz, RMS < 1 Hz, nominal Carrier offset 10 Hz < –73 dBc, nominal ® 10 Hz with R&S FSU-B4 option fitted < –86 dBc, nominal 100 Hz < –98 dBc , typ. –104 dBc 1 kHz < –116 dBc, typ. –124 dBc 10 kHz < –128 dBc, typ. –133 dBc 100 kHz < –128 dBc, typ. –133 dBc 1 MHz < –140 dBc, typ. –146 dBc 10 MHz typ. –160 dBc ® Rohde & Schwarz R&S FSU Spectrum Analyzer 3 Version 16.01, May 2012 0 R&S FSU center frequency 200 MHz R&S FSU center frequency 1 GHz -20 R&S FSU center frequency 5 GHz R&S FSU center frequency 25 GHz -40 R&S FSU center frequency 50 GHz R&S FSU center frequency 65 GHz -60 -80 -100 -120 -140 -160 -180 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 10 MHz Sweep Sweep time time sweep, span = 0 Hz 1 µs to 16000 s in 5 % steps frequency sweep, span ≥ 10 Hz 2.5 ms to 16000 s in steps ≤ 10 % Max. deviation of sweep time 3 % Measurement in time domain with marker and cursor lines (resolution 31.25 ns) Resolution bandwidths Sweep filters 3 dB bandwidths all models except 10 Hz to 20 MHz in 1/2/3/5 sequence, ® ® R&S FSU43, R&S FSU50, model .49 and 50 MHz ® R&S FSU67, model .66 ® ® R&S FSU43, R&S FSU50, model .49 and 10 Hz to 10 MHz in 1/2/3/5 sequence ® R&S FSU67, model .66 Bandwidth uncertainty 10 Hz to 100 kHz (digital) < 3 % 200 kHz to 5 MHz (analog) < 10 % 10 MHz –30 % to +10 % 20 MHz –20 % to +20 % 50 MHz, f ≤ 3.6 GHz –20 % to +20 % 50 MHz, f > 3.6 GHz –30 % to +100 % Shape factor 60 dB:3 dB ≤ 100 kHz < 6 200 kHz to 2 MHz < 12 3 MHz to 10 MHz < 7 20 MHz, 50 MHz < 6, nominal FFT filters 3 dB bandwidths 1 Hz to 30 kHz in 1/2/3/5 sequence Bandwidth uncertainty < 5 %, nominal Shape factor 60 dB:3 dB < 3, nominal EMI filters 6 dB bandwidths 10/100/200 Hz, 1/9/10/100/120 kHz, 1 MHz Bandwidth uncertainty ≤ 120 kHz (digital) < 3 %, nominal 1 MHz (analog) < 10 %, nominal Shape factor 60 dB:3 dB ≤ 120 kHz < 6, nominal 1 MHz < 12, nominal ® 4 Rohde & Schwarz R&S FSU Spectrum Analyzer SSB phase noise (dBc(1Hz)) Version 16.01, May 2012 Channel filters Bandwidths 100/200/300/500 Hz 1/1.5/2/2.4/2.7/3/3.4/4/4.5/5/6/8.5/9/10/ 12.5/14/15/16/18 (RRC)/20/21/ 24.3 (RRC)/25/30/50/100/150/192/200/ 300/500 kHz 1/1.2288/1.28 (RRC)/1.5/2/3/3.84 (RRC)/ 4.096 (RRC)/5 MHz Shape factor 60 dB:3 dB < 2, nominal Bandwidth uncertainty < 2 %, nominal Video bandwidths 1 Hz to 10 MHz in 1/2/3/5 sequence Level Display range displayed noise floor to +30 dBm Maximum input level DC voltage RF input AC coupled 50 V RF input DC coupled 0 V CW RF power RF attenuation 0 dB 20 dBm (= 0.1 W) RF attenuation ≥ 10 dB 30 dBm (= 1 W) Pulse spectral density 97 dB µV/MHz Max. pulse voltage RF attenuation ≥ 10 dB 150 V Max. pulse energy RF attenuation ≥ 10 dB, 10 µs 1 mWs Intermodulation 1 dB compression of input mixer 0 dB RF attenuation ≤ 3.6 GHz +13 dBm, nominal > 3.6 GHz ® R&S FSU8 +10 dBm, nominal ® R&S FSU26/43/46/50/67 +7 dBm, nominal Third-order intercept point (TOI) level 2 × –10 dBm, ∆f > 5 × RBW or 10 kHz, whichever is larger ® R&S FSU3 10 MHz ≤ f < 300 MHz > 17 dBm, typ. 20 dBm in 300 MHz ≤ f ≤ 3.6 GHz > 19 dBm, typ. 25 dBm in ® R&S FSU8 10 MHz ≤ f < 300 MHz > 17 dBm, typ. 20 dBm in 300 MHz ≤ f ≤ 3.6 GHz > 20 dBm, typ. 25 dBm in 3.6 GHz ≤ f ≤ 8 GHz > 18 dBm, typ. 23 dBm in ® R&S FSU26/43/46/50/67 10 MHz ≤ f < 300 MHz > 17 dBm, typ. 20 dBm in 300 MHz ≤ f < 3.6 GHz > 22 dBm, typ. 27 dBm in 3.6 GHz ≤ f < 26.5 GHz > 12 dBm, typ. 15 dBm in ® R&S FSU43/46 26.5 GHz ≤ f ≤ 40 GHz > 12 dBm, typ. 15 dBm in f > 40 GHz > 12 dBm, nominal in ® R&S FSU50 26.5 GHz ≤ f < 28 GHz > 8 dBm, typ. 11 dBm in 28 GHz ≤ f ≤ 40 GHz > 12 dBm, typ. 15 dBm in f > 40 GHz > 12 dBm, nominal in ® R&S FSU67 26.5 GHz ≤ f < 28 GHz > 8 dBm, typ. 11 dBm in 28 GHz ≤ f ≤ 40 GHz > 12 dBm, typ. 15 dBm in 40 GHz < f ≤ 50 GHz > 12 dBm, nominal in f > 50 GHz > 9 dBm, nominal in ® Rohde & Schwarz R&S FSU Spectrum Analyzer 5 Version 16.01, May 2012 Second harmonic intercept (SHI) f < 100 MHz > 35 dBm in 100 MHz < f ≤ 400 MHz > 45 dBm, typ. 55 dBm in 400 MHz < f ≤ 500 MHz > 52 dBm, typ. 60 dBm in 500 MHz < f ≤ 1 GHz > 45 dBm, typ. 55 dBm in 1 GHz < f ≤ 1.8 GHz > 35 dBm in ® R&S FSU8/26/43/46/50 f > 1.8 GHz > 80 dBm, nominal in ® R&S FSU67 1.8 GHz < f ≤ 4.0 GHz > 65 dBm, nominal in f > 4.0 GHz > 75 dBm, nominal in Displayed average noise level 0 dB RF attenuation, termination 50 Ω, log. scaling, normalized to 1 Hz RBW f < 10 kHz: 10 Hz FFT filter, trace average, sweep count = 20 f ≥ 10 kHz: RBW = 1 kHz, VBW = 3 kHz, zero span, sweep time 50 ms, sample detector, trace average, sweep count = 20, mean marker 20 Hz < –90 dBm 100 Hz < –110 dBm 1 kHz < –120 dBm 10 kHz < –130 dBm 100 kHz < –130 dBm 1 MHz < –140 dBm 10 MHz < –153 dBm ® R&S FSU3 20 MHz ≤ f < 2.0 GHz < –155 dBm, typ. –158 dBm 2.0 GHz ≤ f ≤ 3.0 GHz < –153 dBm, typ. –157 dBm 3.0 GHz ≤ f ≤ 3.6 GHz < –152 dBm, typ. –156 dBm ® R&S FSU8 20 MHz ≤ f < 2.0 GHz < –155 dBm, typ. –158 dBm 2.0 GHz ≤ f < 3.0 GHz < –153 dBm, typ. –155 dBm 3.0 GHz ≤ f < 7 GHz < –152 dBm, typ. –154 dBm 7 GHz ≤ f ≤ 8 GHz < –150 dBm, typ. –152 dBm ® R&S FSU26 20 MHz ≤ f < 2 GHz < –152 dBm, typ. –156 dBm 2 GHz ≤ f < 3.6 GHz < –150 dBm, typ. –153 dBm 3.6 GHz ≤ f < 8 GHz < –152 dBm, typ. –156 dBm 8 GHz ≤ f < 13 GHz < –150 dBm, typ. –153 dBm 13 GHz ≤ f < 18 GHz < –148 dBm, typ. –151 dBm 18 GHz ≤ f < 22 GHz < –147 dBm, typ. –150 dBm 22 GHz ≤ f ≤ 26.5 GHz < –145 dBm, typ. –148 dBm ® R&S FSU43 20 MHz ≤ f < 2 GHz < –152 dBm, typ. –156 dBm 2 GHz ≤ f < 13 GHz < –150 dBm, typ. –153 dBm 13 GHz ≤ f < 18 GHz < –148 dBm, typ. –151 dBm 18 GHz ≤ f < 22 GHz < –147 dBm, typ. –150 dBm 22 GHz ≤ f < 26.5 GHz < –145 dBm, typ. –148 dBm 26.5 GHz ≤ f < 40 GHz < –138 dBm, typ. –141 dBm 40 GHz ≤ f ≤ 43 GHz < –133 dBm, typ. –138 dBm ® 6 Rohde & Schwarz R&S FSU Spectrum Analyzer Version 16.01, May 2012 ® R&S FSU46 20 MHz ≤ f < 2 GHz < –152 dBm, typ. –156 dBm 2 GHz ≤ f < 13 GHz < –150 dBm, typ. –153 dBm 13 GHz ≤ f < 18 GHz < –148 dBm, typ. –151 dBm 18 GHz ≤ f < 22 GHz < –147 dBm, typ. –150 dBm 22 GHz ≤ f < 26.5 GHz < –145 dBm, typ. –148 dBm 26.5 GHz ≤ f < 40 GHz < –138 dBm, typ. –141 dBm 40 GHz ≤ f ≤ 46 GHz < –133 dBm, typ. –138 dBm ® R&S FSU50 20 MHz ≤ f < 2 GHz < –152 dBm, typ. –156 dBm 2 GHz ≤ f < 13 GHz < –150 dBm, typ. –153 dBm 13 GHz ≤ f < 18 GHz < –148 dBm, typ. –151 dBm 18 GHz ≤ f < 22 GHz < –147 dBm, typ. –150 dBm 22 GHz ≤ f < 26.5 GHz < –145 dBm, typ. –148 dBm 26.5 GHz ≤ f < 32 GHz < –138 dBm, typ. –141 dBm 32 GHz ≤ f < 46 GHz < –133 dBm, typ. –136 dBm 46 GHz ≤ f ≤ 50 GHz < –128 dBm, typ. –131 dBm ® R&S FSU67 20 MHz ≤ f < 2 GHz < –148 dBm, typ. –152 dBm 2 GHz ≤ f < 13 GHz < –144 dBm, typ. –148 dBm 13 GHz ≤ f < 18 GHz < –142 dBm, typ. –145 dBm 18 GHz ≤ f < 22 GHz < –140 dBm, typ. –144 dBm 22 GHz ≤ f < 26.5 GHz < –138 dBm, typ. –142 dBm 26.5 GHz ≤ f < 40 GHz < –136 dBm, typ. –140 dBm 40 GHz ≤ f < 46 GHz < –132 dBm, typ. –136 dBm 46 GHz ≤ f < 51 GHz < –128 dBm, typ. –132 dBm 51 GHz ≤ f < 57 GHz < –130 dBm, typ. –136 dBm 57 GHz ≤ f < 65 GHz < –126 dBm, typ. –130 dBm 65 GHz ≤ f ≤ 67 GHz < –120 dBm, typ. –124 dBm improvement with noise correction ON max. 13 dB, nominal Immunity to interference Image frequency f ≤ 3.6 GHz > 90 dB suppression, typ. > 110 dB 3.6 GHz < f ≤ 40 GHz > 70 dB suppression, typ. > 100 dB 40 GHz < f ≤ 50 GHz > 70 dB suppression, nominal f > 50 GHz > 47 dB suppression f = receive frequency Intermediate frequency f ≤ 3.6 GHz > 90 dB suppression, typ. > 110 dB 3.6 GHz < f ≤ 4.2 GHz typ. 70 dB suppression 4.2 GHz < f ≤ 50 GHz > 70 dB suppression, typ. > 90 dB f > 50 GHz > 47 dB suppression, typ. > 50 dB f = receive frequency Spurious response f > 1 MHz, without input signal, < –103 dBm 0 dB RF attenuation Other interfering signals ∆f > 100 kHz mixer level < –10 dBm, f ≤ 2.3 GHz < –80 dBc in mixer level < –35 dBm, < –70 dBc 2.3 GHz < f < 4 GHz in mixer level < –10 dBm 4 GHz ≤ f < 8 GHz < –70 dBc 8 GHz ≤ f < 16 GHz < –64 dBc 16 GHz ≤ f < 26 GHz < –58 dBc 26.5 GHz ≤ f < 40 GHz < –52 dBc 40 GHz ≤ f < 50 GHz < –52 dBc, nominal 50 GHz ≤ f < 64 GHz < –47 dBc, nominal 64 GHz ≤ f ≤ 67 GHz < –43 dBc, nominal f = receive frequency ® Rohde & Schwarz R&S FSU Spectrum Analyzer 7 Version 16.01, May 2012 Level display Screen (625 × 500) pixel (one diagram), max. 2 diagrams with independent settings Logarithmic level axis 1 dB to 200 dB, in steps of 1/2/5 Linear level axis 10 % of reference level per level division, 10 divisions or logarithmic scaling Number of traces one measurement diagram 3 two measurement diagrams 6 Trace detector Max Peak, Min Peak, Auto Peak (Normal), sample, RMS, average, EMI detectors Quasi Peak, CISPR-RMS, CISPR-AV Number of measurement points default value 625 range 155 to 30001 in steps of about a factor of 2 Trace functions Clear/Write, Max Hold, Min Hold, Average Trace update rate local measurement, display update rate, 80 per second 625 points, zero span remote measurement, display OFF zero span/sweep time 1 ms 70 per second span = 10 MHz, sweep time 2.5 ms 50 per second Setting range of reference level logarithmic level display –130 dBm to (+5 dBm + RF attenuation), max. 30 dBm, in steps of 0.1 dB linear level display 7.0 nV to 7.07 V in steps of 1 % Units of level axis logarithmic level display dBm, dBµV, dBmV, dBµA, dBpW linear level display µV, mV, µA, mA, pW, nW Level measurement uncertainty Absolute level uncertainty at 128 MHz RBW = 10 kHz, level –30 dBm, < 0.2 dB (σ = 0.07 dB) reference level –30 dBm, RF attenuation 10 dB Frequency response DC coupling, RF attenuation ≥ 10 dB, +20 °C to +30 °C referenced to 128 MHz 20 Hz ≤ f < 10 MHz < 0.5 dB (σ = 0.17 dB) 10 MHz ≤ f < 3.6 GHz < 0.3 dB (σ = 0.1 dB) 3.6 GHz ≤ f < 8 GHz, span < 1 GHz < 1.5 dB (σ = 0.5 dB) 8 GHz ≤ f < 22 GHz, span < 1 GHz < 2 dB (σ = 0.7 dB) 22 GHz ≤ f < 40 GHz, span < 1 GHz < 2.5 dB (σ = 0.8 dB) 40 GHz ≤ f < 50 GHz, span < 1 GHz < 3 dB (σ = 1.0 dB) 50 GHz ≤ f ≤ 67 GHz, span < 1 GHz < 4 dB (σ = 1.3 dB) RF attenuation > 40 dB or add 0.5 dB to above values f ≥ 3.6 GHz, span ≥ 1 GHz DC coupling, RF attenuation ≥ 10 dB, +5 °C to +45 °C 20 Hz ≤ f < 3.6 GHz < 0.6 dB (σ = 0.2 dB) 3.6 GHz ≤ f < 26.5 GHz add 0.5 dB to above values 26.5 GHz ≤ f < 50 GHz add 1.0 dB to above values f ≥ 50 GHz add 1.5 dB to above values RF attenuation > 40 dB or add 0.5 dB to above values f ≥ 3.6 GHz, span ≥ 1 GHz Attenuator switching uncertainty f = 128 MHz < 0.2 dB (σ = 0.07 dB) 0 dB to 70 dB, referenced to 10 dB attenuation Uncertainty of reference level setting RF attenuation 10 dB, referenced to < 0.15 dB (σ = 0.05 dB) –10 dBm reference level setting ® 8 Rohde & Schwarz R&S FSU Spectrum Analyzer Version 16.01, May 2012 Display nonlinearity +20 °C to +30 °C, mixer level ≤ –10 dBm Logarithmic level display RBW ≤ 100 kHz or channel filters, S/N > 20 dB 0 dB to –70 dB < 0.1 dB (σ = 0.03 dB) –70 dB to –90 dB < 0.3 dB (σ =0.1 dB) 200 kHz ≤ RBW ≤ 10 MHz, S/N > 16 dB 0 dB to –50 dB < 0.2 dB (σ =0.07 dB) –50 dB to –70 dB < 0.5 dB (σ =0.17 dB) RBW > 10 MHz, S/N > 16 dB 0 dB to –50 dB < 0.5 dB (σ =0.17 dB) Linear level display 5 % of reference level Bandwidth switching error referenced to RBW = 10 kHz 1 Hz to 100 kHz < 0.1 dB (σ =0.03 dB) 200 kHz to 3 MHz < 0.2 dB (σ =0.07 dB) 5 MHz to 50 MHz < 0.5 dB (σ =0.15 dB) FFT filter 1 Hz to 3 kHz < 0.2 dB (σ =0.07 dB) Total measurement uncertainty signal level 0 dB to –70 dB below reference level, S/N > 20 dB, 10 dB ≤ RF attenuation ≤ 40 dB, span/RBW < 100, 95 % confidence level, +20 °C to +30 °C, mixer level ≤ –10 dBm 20 Hz ≤ f < 10 MHz, RBW ≤ 100 kHz 0.4 dB 20 Hz ≤ f < 10 MHz, RBW > 100 kHz 0.5 dB 10 MHz ≤ f < 3.6 GHz, RBW ≤ 100 kHz 0.3 dB 10 MHz ≤ f < 3.6 GHz, RBW > 100 kHz 0.5 dB 3.6 GHz ≤ f < 8 GHz 1.2 dB 8 GHz ≤ f < 22 GHz 1.5 dB 22 GHz ≤ f < 40 GHz 1.8 dB 40 GHz ≤ f < 50 GHz 2.2 dB 50 GHz ≤ f < 67 GHz 2.8 dB I/Q data Interface GPIB or LAN interface Memory length max. 512 ksample I and Q Sample length 24 bit, each I and Q Sample rate settable in steps of 0.5 15.625 kHz to 32 MHz –n (32 MHz × 2 , n = 0 to 11) Max. signal bandwidth sample rate ≤ 2 MHz 0.8 × sample rate 4 MHz 2.8 MHz 8 MHz 4.8 MHz 16 MHz 7 MHz 32 MHz 9 MHz IF pre-filter bandwidth 300 kHz to 10 MHz, 1/2/3/5 steps Audio demodulation AF demodulation types AM and FM Audio output loudspeaker and phone jack Marker stop time in spectrum mode 100 ms to 60 s ® Rohde & Schwarz R&S FSU Spectrum Analyzer 9 Version 16.01, May 2012 Trigger functions Trigger Trigger source free run, video, external, IF level (mixer level 10 dBm to –50 dBm) Trigger offset span ≥ 10 Hz 125 ns to 100 s, resolution min. 125 ns (or 1 % of offset) span = 0 Hz ±(125 ns to 100 s), resolution min. 125 ns, dependent on sweep time Max. deviation of trigger offset ±(31.25 ns + (0.1 % × trigger offset)) Gated sweep Gate source external, IF level, video Gate delay 1 µs to 100 s Gate length 125 ns to 100 s, resolution min. 125 ns or 1 % of gate length Max. deviation of gate length ±(31.25 ns + (0.05 % × gate length)) Inputs and outputs (front panel) RF input Impedance 50 Ω ® ® Connector R&S FSU3, R&SFSU8 N female ® R&S FSU26 test port adapter APC 3.5 mm/N female ® ® R&S FSU43, R&S FSU46 test port adapter 2.92 mm (K)/N female ® R&S FSU50 test port adapter 2.4 mm/N female ® R&S FSU67 1.85 mm/V female VSWR RF attenuation ≥ 10 dB, DC coupled f < 3.6 GHz < 1.5 ® R&S FSU8 3.6 GHz ≤ f < 8 GHz < 2 ® R&S FSU26/43/46/50/67 3.6 GHz ≤ f < 18 GHz < 1.8 18 GHz ≤ f < 26.5 GHz < 2.0 26.5 GHz ≤ f < 40 GHz < 2.5 40 GHz ≤ f < 50 GHz < 3, nominal 50 GHz ≤ f ≤ 67 GHz < 3.5, nominal RF attenuation < 10 dB or AC coupled typ. 1.5 Setting range of attenuator 0 dB to 75 dB, in 5 dB steps Probe power supply Supply voltages +15 V DC, –12.6 V DC and ground, max. 150 mA, nominal Power supply for antennas etc 5-pin connector Supply voltages ±10 V and ground, max. 100 mA, nominal Power supply for noise source BNC female Output voltage 0 V and 28 V, switchable, nominal USB interface type A plug, version 2.0 AF output Connector 3.5 mm mini jack Output impedance 10 Ω Open-circuit voltage up to 1.5 V, adjustable ® 10 Rohde & Schwarz R&S FSU Spectrum Analyzer Version 16.01, May 2012 Inputs and outputs (rear panel) IF 20.4 MHz BNC female Impedance 50 Ω Bandwidth RBW ≤ 30 kHz 1.67 × resolution bandwidth, min. 2.6 kHz RBW = 50 kHz, 100 kHz 400 kHz 200 kHz ≤ RBW ≤ 10 MHz equal to resolution bandwidth Level RBW ≤ 100 kHz, FFT filter, –20 dBm at reference level mixer level > –70 dBm RBW = 200 kHz to 10 MHz, 0 dBm at reference level mixer level > –50 dBm ® IF 404.4 MHz not available with R&S FSU43, BNC female ® R&S FSU50, model .49 and ® R&S FSU67, model .66, active only if RBW > 10 MHz Impedance 50 Ω Bandwidth RBW > 10 MHz equal to resolution bandwidth Level mixer level ≤ 0 dBm typ. 10 dB below mixer level Video output BNC female Impedance 50 Ω Output voltage RBW ≥ 200 kHz, logarithmic scaling, 0 V to 1 V (EMF) full scale Reference output BNC female Impedance 50 Ω Output frequency internal reference 10 MHz external reference same as reference input signal Level > 0 dBm, nominal Reference input BNC female Impedance 50 Ω Input frequency range 1 MHz ≤ f ≤ 20 MHz, in 1 Hz steps in Required level > 0 dBm from 50 Ω Sweep output BNC female Output voltage 0 V to 5 V, proportional to displayed frequency External trigger/gate input BNC female Trigger voltage 0.5 V to 3.5 V Input impedance ≥ 10 kΩ IEC/IEEE bus control interface to IEC 625-2 (IEEE 488.2) Command set SCPI 1997.0 or HP8566 compatible Connector 24-pin Amphenol female Interface functions SH1, AH1, T6, L4, SR1, RL1, PP1, DC1, DT1, C0 LAN interface 10/100 BaseT, RJ45 USB interface upper connector type A plug, version 1.1 lower connector type A plug, version 2.0 Serial interface RS-232-C (COM), 9-pin female connectors Printer interface parallel (Centronics compatible) Mouse interface PS/2 compatible Connector for external monitor (VGA) 15-pin D-Sub ® Rohde & Schwarz R&S FSU Spectrum Analyzer 11 Version 16.01, May 2012 General specifications Display 21 cm LC TFT color display (8.4") Resolution (800 × 600) pixel (SVGA resolution) –5 Pixel failure rate < 1 × 10 Mass memory Mass memory hard disk, USB flash disk (not supplied) Data storage >500 instrument settings and traces ® Mass memory R&S FSU-B20 option hard disk replaced by a flash disk Temperature Ranges operating temperature range +5° C to +40 °C permissible temperature range +0° C to +50 °C storage temperature range –40°C to +70 °C ® R&S FSU-B20 option operating temperature range 0 °C to +50 °C permissible temperature range 0 °C to +55 °C Climatic loading +40 °C at 95 % relative humidity, in line with EN 60068-2-30 Mechanical resistance Vibration sinusoidal 5 Hz to 150 Hz, max. 2 g at 55 Hz; 0.5 g from 55 Hz to 150 Hz; in line with EN 60068-2-6 random 10 Hz to 100 Hz, acceleration 1 g (RMS) Shock 40 g shock spectrum, in line with MIL-STD-810E Method 516.4 Procedure I and MIL-PRF-28800F ® R&S FSU-B20 option: random vibration 10 Hz to 300 Hz, acceleration 1.9 g (RMS) Recommended calibration interval operation with external reference 2 years operation with internal reference 1 year RFI suppression in line with EMC Directive 2004/108/EC including: IEC/EN 61326-1, IEC/EN 61326-2-1, CISPR 11/EN 55011, IEC/EN 61000-3-2, IEC/EN 61000-3-3 Power supply AC supply 100 V to 240 V, 3.1 A to 1.3 A; 50 Hz to 400 Hz, class of protection I in line with VDE 411 ® ® Power consumption R&S FSU3, R&S FSU8 typ. 130 VA ® R&S FSU26/43/46/50/67 typ. 150 VA Safety in line with EN 61010-1, IEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-4 Test mark VDE, GS, CSA, CSA-NRTL Dimensions W × H × D 435 mm × 192 mm × 460 mm (17.13 in × 7.56 in × 18.11 in) ® Weight, without options, nominal R&S FSU3 14.6 kg (32.2 lb) ® R&S FSU8 15.4 kg (33.95 lb) ® R&S FSU26 16.5 kg (36.4 lb) ® R&S FSU43/46/50 16.8 kg (37.0 lb) ® R&S FSU67 17.4 kg (38.3 lb) ® 12 Rohde & Schwarz R&S FSU Spectrum Analyzer Version 16.01, May 2012 ® R&S FSU-B9 tracking generator, ® R&S FSU-B12 attenuator for tracking generator ® (not available for R&S FSU67) Unless specified otherwise, specifications not valid for frequency range from –3 × RBW to +3 × RBW, however at least not valid from –100 kHz to +100 kHz. Maximum output level +5 dBm (peak modulation in the case of amplitude-modulated signals). Frequency Frequency range 100 kHz to 3.6 GHz Resolution 1 Hz Frequency offset Setting range ±200 MHz Resolution 1 Hz Spectral purity SSB phase noise f = 500 MHz, carrier offset 10 kHz normal mode typ. –120 dBc (1 Hz) with frequency offset typ. –110 dBc (1 Hz) with FM modulation ON typ. –110 dBc (1 Hz) Level Level setting range –30 dBm to +5 dBm in steps of 0.1 dB ® with option R&S FSU-B12 –100 dBm to +5 dBm in steps of 0.1 dB Max. deviation of output level Absolute f = 128 MHz, < 1 dB (σ = 0.34 dB) output level –20 dBm to 0 dBm Frequency response referenced to level at 128 MHz, sweep time > 100 ms, +5 °C to +45 °C output level –20 dBm to 0 dBm, < 3 dB, typ. 1.9 dB 100 kHz to 3.6 GHz output level –30 dBm to –20 dBm, 3 dB f = 100 kHz to 3.6 GHz additional deviation with < 1 dB ® R&S FSU-B12, 100 kHz to 3.6 GHz Dynamic range Attenuation measurement range RBW = 1 kHz, f > 10 MHz 100 dB Harmonics output level –10 dBm typ. –30 dBc Spurious, nonharmonics output level 0 dBm typ. –30 dBc Level sweep Level range 0 dBm to –25 dBm Max. deviation of output level f = 100 kHz to 2 GHz output level 0 dBm to –5 dBm < 1.5 dB output level –5 dBm to –15 dBm < 2 dB output level –15 to –25 dBm < 3 dB f = 2 GHz to 3 GHz < 3 dB output level 0 dBm to –25 dBm ® Rohde & Schwarz R&S FSU Spectrum Analyzer 13 Version 16.01, May 2012 Modulation Modulation format external I/Q, AM, FM Input voltage full scale AM, FM, V 1 V pp 2 2 U + U = I/Q i q 0.5 V AM f > f , span = 0 Hz Center Mod Modulation depth 0 % to 99 % Modulation frequency response 0 Hz to 5 MHz 1 dB 0 Hz to 30 MHz 3 dB FM f > f , span = 0 Hz Center Mod Frequency deviation full range 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz Modulation frequency range deviation ≤ 10 MHz 0 Hz to 1 kHz deviation ≤ 1 MHz 0 Hz to 100 kHz Modulation frequency response 0 Hz to 100 kHz 1 dB I/Q modulation f > f , span = 0 Hz Center Mod Modulation frequency response 0 Hz to 5 MHz 1 dB 0 Hz to 30 MHz 3 dB ® Modulation deviation of tracking I/Q modulation, typical values, baseband signals generated by the R&S AMIQ generator EVM NADC/TETRA/PDC RMS 2 % peak 4 % PHS RMS 2 % peak 5 % Phase error GSM/DCS1800/PCS1900 RMS 1.5° peak 5° Rho factor IS-95 CDMA 0.997 Inputs and outputs (front panel) RF output N female, 50 Ω VSWR 100 kHz ≤ f ≤ 2 GHz 1.2 2 GHz ≤ f ≤ 3.6 GHz 1.5 Inputs and outputs (rear panel) TG I/AM IN BNC female Impedance 50 Ω Input voltage V 1 V pp TG Q/FM IN BNC female Impedance 50 Ω Input voltage V 1 V pp ® 14 Rohde & Schwarz R&S FSU Spectrum Analyzer Version 16.01, May 2012 ® R&S FSU-B21 LO/IF ports for external mixers ® (for R&S FSU26/43/46/50/67 only) LO signal Frequency range 7.0 GHz to 15.5 GHz Level +20 °C to +30 °C +15.5 dBm ± 1 dB +5 °C to +40 °C +15.5 dBm ± 3 dB IF input IF frequency 404.4 MHz Full scale level 2-port mixer –20 dBm (LO output/IF input, front panel) 3-port mixer (IF input, front panel) –20 dBm Level uncertainty IF input level –30 dBm, RBW 30 kHz, two-port mixer, LO output/IF input (front panel) +20 °C to +30 °C < 1 dB +5 °C to +40 °C < 3 dB three-port mixer, IF input (front panel) +20 °C to +30 °C < 1 dB +5 °C to +40 °C < 3 dB Inputs and outputs (front panel) LO output/IF input SMA female, 50 Ω IF input SMA female, 50 Ω ® Rohde & Schwarz R&S FSU Spectrum Analyzer 15 Version 16.01, May 2012 ® R&S FSU-B23 RF preamplifier ® ® (for R&S FSU26 only, requires R&S FSU-B25 option) Level measurement uncertainty Frequency response preamplifier ON 3.6 GHz to 8 GHz < 2.0 dB (σ = 0.7 dB) 8 GHz to 22 GHz < 2.5 dB (σ = 0.8 dB) 22 GHz to 26.5 GHz < 3.0 dB (σ = 1 dB) Displayed average noise level 0 dB RF attenuation, termination 50 Ω, RBW = 1 kHz, VBW = 3 kHz, zero span, sweep time 50 ms, sample detector, log. scaling, trace average, sweep count = 20, mean marker, normalized to 1 Hz RBW preamplifier OFF ® 3.6 GHz to 8 GHz R&S FSU26 specifications + 2 dB ® 8 GHz to 26.5 GHz R&S FSU26 specifications + 3 dB preamplifier ON 3.6 GHz to 8 GHz < –162 dBm, typ. –165 dBm 8 GHz to 13 GHz < –159 dBm, typ. –162 dBm 13 GHz to 18 GHz < –157 dBm, typ. –160 dBm 18 GHz to 22 GHz < –154 dBm, typ. –159 dBm 22 GHz to 26.5 GHz < –150 dBm, typ. –155 dBm improvement with noise correction ON max. 13 dB, nominal ® 16 Rohde & Schwarz R&S FSU Spectrum Analyzer Version 16.01, May 2012 ® ® R&S FSU-B24 preamplifier (for R&S FSU26/43/46/50 only) ® Frequency range R&S FSU26 100 kHz to 26.6 GHz ® R&S FSU43 100 kHz to 43 GHz ® R&S FSU46 100 kHz to 46 GHz ® 1 R&S FSU50 100 kHz to 50 GHz Nominal gain 30 dB Displayed average noise level (DANL) RF attenuation = 0 dB, termination = 50 Ω, log. scaling, normalized to 1 Hz RBW, preamplifier OFF f < 10 kHz: RBW = 10 Hz FFT filter, trace average, sweep count = 20, f ≥ 10 kHz: RBW = 1 kHz, VBW = 3 kHz, span = 0 Hz, sweep time = 50 ms, trace average, sample detector , sweep count = 20, mean marker 20 Hz < –90 dBm 100 Hz < –110 dBm 1 kHz < –120 dBm 10 kHz < –130 dBm 100 kHz < –130 dBm 1 MHz < –140 dBm 10 MHz < –151 dBm 20 MHz ≤ f < 2 GHz < –151 dBm, typ. –154 dBm 2 GHz ≤ f < 8 GHz < –149 dBm, typ. –152 dBm 8 GHz ≤ f < 13 GHz < –147 dBm, typ. –150 dBm 13 GHz ≤ f < 18 GHz < –145 dBm, typ. –148 dBm 18 GHz ≤ f < 22 GHz < –144 dBm, typ. –147 dBm 22 GHz ≤ f < 26.5 GHz < –140 dBm, typ. –143 dBm 26.5 GHz ≤ f < 32 GHz < –135 dBm, typ. –138 dBm 32 GHz ≤ f < 42 GHz < –130 dBm, typ. –133 dBm 42 GHz ≤ f ≤ 50 GHz < –125 dBm, typ. –128 dBm RF attenuation = 0 dB, termination = 50 Ω, log. scaling, normalized to 1 Hz RBW, preamplifier ON RBW = 1 kHz, VBW = 3 kHz, span = 0 Hz, sweep time = 50 ms, trace average, sample detector, sweep count = 20, mean marker 100 kHz < –140 dBm 1 MHz < –150 dBm 10 MHz < –163 dBm 20 MHz ≤ f < 2 GHz < –164 dBm, typ. –167 dBm 2 GHz ≤ f < 3.6 GHz < –163 dBm, typ. –166 dBm 3.6 GHz ≤ f < 20 GHz < –165 dBm, typ. –168 dBm 20 GHz ≤ f < 33 GHz < –163 dBm, typ. –166 dBm 33 GHz ≤ f < 42 GHz < –158 dBm, typ. –161 dBm 42 GHz ≤ f ≤ 50 GHz < –152 dBm, typ. –155 dBm improvement with noise correction ON max. 13 dB, nominal 1 ® Not available for R&S FSU50, model .49. ® Rohde & Schwarz R&S FSU Spectrum Analyzer 17 Version 16.01, May 2012 Level measurement uncertainty RBW = 10 kHz, level –30 dBm, reference level –30 dBm, RF attenuation 10 dB Absolute level uncertainty at 128 MHz preamplifier OFF < 0.2 dB (σ = 0.07 dB) preamplifier ON < 0.3 dB (σ = 0.1 dB) Frequency response DC coupling, RF attenuation ≥ 10 dB, preamplifier OFF, +20 °C to +30 °C referenced to 128 MHz 20 Hz ≤ f < 10 MHz < 0.5 dB (σ = 0.16 dB) 10 MHz ≤ f < 3.6 GHz < 0.3 dB (σ = 0.1 dB) 3.6 GHz ≤ f < 8 GHz < 1.5 dB (σ = 0.5 dB) 8 GHz ≤ f < 22 GHz, span < 1 GHz < 2.0 dB (σ = 0.7 dB) 22 GHz ≤ f < 40 GHz, span < 1 GHz < 2.5 dB (σ = 0.8 dB) 40 GHz ≤ f ≤ 50 GHz, span < 1 GHz < 3.0 dB (σ = 1 dB) RF attenuation > 40 dB or add 0.5 dB to above values f ≥ 3.6 GHz, span ≥ 1 GHz DC coupling, RF attenuation ≥ 10 dB, preamplifier OFF, +5 °C to +45 °C 20 Hz ≤ f < 3.6 GHz < 0.6 dB (σ = 0.2 dB) 3.6 GHz ≤ f < 26.5 GHz add 0.5 dB to above values 26.5 GHz ≤ f ≤ 50 GHz add 1.0 dB to above values RF attenuation > 40 dB or add 0.5 dB to above values f ≥ 3.6 GHz, span ≥ 1 GHz DC coupling, RF attenuation ≥ 10 dB, preamplifier ON, +20 °C to +30 °C 100 kHz ≤ f < 10 MHz < 0.8 dB (σ = 0.27 dB) 10 MHz ≤ f < 3.6 GHz < 0.6 dB (σ = 0.2 dB) 3.6 GHz ≤ f < 8 GHz < 2.0 dB (σ = 0.7 dB) 8 GHz ≤ f < 22 GHz, span < 1 GHz < 2.5 dB (σ = 0.8 dB) 22 GHz ≤ f < 40 GHz, span < 1 GHz < 3.0 dB (σ = 1 dB) 40 GHz ≤ f ≤ 50 GHz, span < 1 GHz < 3.5 dB (σ = 1.2 dB) RF attenuation > 40 dB or add 0.5 dB to above values f ≥ 3.6 GHz, span ≥ 1 GHz DC coupling, RF attenuation ≥ 10 dB, preamplifier ON, +5 °C to +45 °C 100 kHz ≤ f < 10 MHz < 1.0 dB (σ = 0.3 dB) 10 MHz ≤ f < 3.6 GHz < 0.8 dB (σ = 0.27 dB) 3.6 GHz ≤ f < 26.5 GHz add 0.5 dB to above values 26.5 GHz ≤ f ≤ 50 GHz add 1.0 dB to above values RF attenuation > 40 dB or add 0.5 dB to above values f ≥ 3.6 GHz, span ≥ 1 GHz Intermodulation Second harmonic intercept (SHI) f > 1.8 GHz > 65 dBm, nominal in ® 18 Rohde & Schwarz R&S FSU Spectrum Analyzer Version 16.01, May 2012 ® R&S FSU-B25 electronic attenuator and low-noise preamplifier, ® R&S FSU-B85 extended specifications for low-noise preamplifier Frequency ® 2 Frequency range R&S FSU3/26/43/46/50 electronic attenuator 10 MHz to 3.6 GHz preamplifier 100 kHz to 3.6 GHz ® R&S FSU8 electronic attenuator 10 MHz to 8 GHz preamplifier 100 kHz to 8 GHz Setting range Electronic attenuator 0 dB to 30 dB, in 5 dB steps Preamplifier 20 dB, switchable Level measurement uncertainty Frequency response with preamplifier or electronic attenuator 10 MHz to 50 MHz < 1 dB (σ = 0.34 dB) 50 MHz to 3.6 GHz < 0.6 dB (σ = 0.2 dB) 3.6 GHz to 8 GHz < 2.0 dB (σ = 0.7 dB) Reference error at 128 MHz, RBW ≤ 100 kHz, reference level –30 dBm, RF attenuation 10 dB electronic attenuator < 0.3 dB (σ = 0.1 dB) preamplifier < 0.3 dB (σ = 0.1 dB) Displayed average noise level 0 dB RF attenuation, termination 50 Ω, RBW = 1 kHz, VBW = 3 kHz, zero span, sweep time 50 ms, sample detector, log. scaling, trace average, sweep count = 20, mean marker, normalized to 1 Hz RBW preamplifier ON ® R&S FSU3/8/26 10 MHz to 2.0 GHz < –162 dBm 2.0 GHz to 3.6 GHz < –160 dBm ® R&S FSU8 3.6 GHz to 8 GHz < –157 dBm ® R&S FSU43/46/50 10 MHz to 40 MHz < –160 dBm 40 MHz to 2 GHz < –162 dBm 2 GHz to 3.6 GHz < –160 dBm ® with the R&S FSU-B25 built in, the average noise level values displayed by the base ® units degrade by (R&S FSU-B25 OFF) 20 Hz to 3.6 GHz 1 dB ® R&S FSU8 3.6 GHz to 8 GHz 2 dB preamplifier OFF, electronic attenuator 0 dB 20 Hz to 3.6 GHz typ. 2.5 dB ® R&S FSU8 3.6 GHz to 8 GHz typ. 3.5 dB improvement with noise correction ON max. 13 dB, nominal 2 ® Not available for R&S FSU50, model .49. ® Rohde & Schwarz R&S FSU Spectrum Analyzer 19 Version 16.01, May 2012 Displayed average noise level with 0 dB RF attenuation, termination 50 Ω, RBW = 1 kHz, VBW = 3 kHz, zero span, ® R&S FSU-B85, extended specification sweep time 50 ms, sample detector, log. scaling, trace average, sweep count = 20, for low-noise preamplifier mean marker, normalized to 1 Hz RBW preamplifier ON ® ® R&S FSU3, R&S FSU8 10 MHz to 100 MHz < –164 dBm, typ. –166 dBm 100 MHz to 200 MHz < –168 dBm, typ. –170 dBm 200 MHz to 2 GHz < –166 dBm, typ. –168 dBm 2 GHz to 3.6 GHz < –165 dBm, typ. –167 dBm ® R&S FSU8 3.6 GHz to 6 GHz < –165 dBm, typ. –167 dBm 6 GHz to 8 GHz < –163 dBm, typ. –165 dBm improvement with noise correction ON max. 11 dB, nominal Intermodulation Third-order intercept point (TOI) electronic attenuator ON, Δf > 5 × RBW or 10 kHz 10 MHz to 300 MHz > 17 dBm 300 MHz to 3.6 GHz > 20 dBm 3.6 GHz to 8 GHz > 18 dBm ® R&S FSU-B27 broadband FM demodulator output Frequency deviation Frequency deviation ≤ 5 MHz Deviation + modulation frequency ≤ 5 MHz FM slope load impedance 50 Ω 280 mV/MHz ± 20 % Frequency response DC to 1 MHz (< 1 MHz deviation) < 0.4 dB 4 MHz (< 1 MHz deviation) typ. 3 dB Distortion 1 MHz deviation + > 30 dBc 1 MHz modulation frequency Residual FM LF-lowpass 100 kHz < 100 Hz RMS Lowpass filters 3 dB bandwidth 30 kHz, 100 kHz, 300 kHz, 1 MHz ® 20 Rohde & Schwarz R&S FSU Spectrum Analyzer Version 16.01, May 2012 Ordering information Designation Type Order No. ® Spectrum Analyzer, 20 Hz to 3.6 GHz R&SFSU3 1313.9000.03 ® Spectrum Analyzer, 20 Hz to 8 GHz R&SFSU8 1313.9000.08 ® Spectrum Analyzer, 20 Hz to 26.5 GHz R&SFSU26 1313.9000.26 ® Spectrum Analyzer, 20 Hz to 43 GHz R&SFSU43 1313.9000.43 ® Spectrum Analyzer, 20 Hz to 46 GHz R&SFSU46 1313.9000.46 ® 3 Spectrum Analyzer, 20 Hz to 50 GHz R&S FSU50 1313.9000.49 ® Spectrum Analyzer, 20 Hz to 50 GHz R&SFSU50 1313.9000.50 ® 3 Spectrum Analyzer, 20 Hz to 67 GHz R&S FSU67 1313.9000.66 ® Spectrum Analyzer, 20 Hz to 67 GHz R&SFSU67 1313.9000.67 Accessories supplied Power cable, printed quick start guide and CD-ROM (with operating manual and service manual). ® R&S FSU26: test port adapter with 3.5 mm female (1021.0512.00) and N female (1021.0535.00) connector. ® ® R&S FSU43, R&S FSU46: test port adapter with 2.92 mm (K) female (1036.4790.00) and N female (1036.4777.00) connector. ® R&S FSU50: test port adapter with 2.4 mm female (1088.1627.02) and N female (1036.4777.00) connector. 3 Max. bandwidth 10 MHz. ® Rohde & Schwarz R&S FSU Spectrum Analyzer 21 Version 16.01, May 2012 Options Designation Type Order No. Retrofittable Remarks Options ® OCXO, low aging/improved phase noise at 10 Hz R&SFSU-B4 1144.9000.02 yes carrier offset ® Tracking Generator, 100 kHz to 3.6 GHz R&S FSU-B9 1142.8994.02 yes not available for ® R&S FSU67 ® External Generator Control R&SFSP-B10 1129.7246.03 yes ® ® ® Output Attenuator, 0 dB to 70 dB, for R&SFSU-B9 R&SFSU-B12 1142.9349.02 yes requires R&S FSU-B9, not available for ® R&S FSU67 ® ® Removable Hard Disk R&SFSU-B18 1303.0400.12 no excludes R&S FSU-B20 ® ® ® Second Hard Disk for R&SFSU-B18 R&SFSU-B19 1303.0600.02 requires R&S FSU-B18 ® Extended Environmental Specifications R&SFSU-B20 1155.1606.11 no ® LO/IF Ports for External Mixers R&SFSU-B21 1157.1090.03 yes only for ® R&S FSU26/43/46/50/67 ® ® 20 dB Preamplifier, 3.6 GHz to 26.5 GHz R&SFSU-B23 1157.0907.02 no only for R&S FSU26, ® requires R&S FSU-B25 ® 30 dB Preamplifier, 100 kHz to 50 GHz R&SFSU-B24 1157.2100.50 yes only for ® R&S FSU26/43/46/50, not available for ® R&S FSU50, model .49., ® excludes R&S FSU-B23, ® R&S FSU-B25 ® Electronic Attenuator, 0 dB to 30 dB, R&S FSU-B25 1144.9298.02 yes not available for ® and 20 dB Preamplifier (3.6 GHz) R&S FSU50, model .49, ® and R&S FSU67 ® Broadband FM Demodulator Output, R&SFSU-B27 1157.2000.02 yes max. dev. 5 MHz ® Vector Signal Analyzer R&S FSU-B73 1169.5696.03 no not available for ® R&S FSU67 ® ® Extended Specifications for Low-Noise Preamplifier R&SFSU-B85 1303.3000.02 no only for R&S FSU3 and ® ® of R&S FSU-B25 option R&S FSU8, ® requires R&S FSU-B25 Firmware/Software ® GSM/EDGE Application Firmware R&SFS-K5 1141.1496.02 ® FM Measurement Demodulator R&SFS-K7 1141.1796.02 ® 4 ® Bluetooth Application Firmware R&SFS-K8 1157.2568.02 ® Power Sensor Measurements R&SFS-K9 1157.3006.02 ® Application Firmware for Noise Figure and R&SFS-K30 1300.6508.02 preamplifier ® Gain Measurements (e.g. R&S FSU-B25) recommended ® Application Firmware for Phase Noise Measurement R&SFS-K40 1161.8138.02 ® 3GPP BTS/Node B FDD Application Firmware R&SFS-K72 1154.7000.02 ® 3GPP UE FDD Application Firmware (incl HSUPA) R&SFS-K73 1154.7252.02 ® ® 3GPP HSDPA BTS Application Firmware R&SFS-K74 1300.7156.02 requires R&S FS-K72 ® 3GPP TD-SCDMA BTS Application Firmware R&SFS-K76 1300.7291.02 ® 3GPP TD-SCDMA UE Application Firmware R&SFS-K77 1300.8100.02 ® 5 ® CDMA2000 /IS-95 (cdmaOne)/1xEV-DV BTS R&SFS-K82 1157.2316.02 Application Firmware ® ® CDMA2000 1xEV-DV MS Application Firmware R&SFS-K83 1157.2416.02 ® ® CDMA2000 1xEV-DO BTS Application Firmware R&SFS-K84 1157.2851.02 (incl Rev A) ® ® CDMA2000 1xEV-DO MS Application Firmware R&SFS-K85 1300.6689.02 4 ® The Bluetooth word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by Rohde & Schwarz is under license. 5 ® CDMA2000 is a registered trademark of the Telecommunications Industry Association (TIA-USA). ® 22 Rohde & Schwarz R&S FSU Spectrum Analyzer Version 16.01, May 2012 Recommended extras Designation Type Order No. Headphones 0708.9010.00 ® IEC/IEEE Bus Cable, length 1 m R&SPCK 0292.2013.10 ® IEC/IEEE Bus Cable, length 2 m R&SPCK 0292.2013.20 ® 19" Rack Adapter R&SZZA-411 1096.3283.00 ® Adapter for mounting on telescopic rails R&SZZA-T45 1109.3774.00 ® (only with 19" Adapter R&S ZZA-411) Matching pads, 50 Ω/75 Ω ® L Section, matching at both ends R&SRAM 0358.5414.02 ® Series Resistor, 25 Ω, matching at one R&SRAZ 0358.5714.02 end (taken into account in instrument function RF INPUT 75 Ω) SWR bridges, 50 Ω ® SWR Bridge, 5 MHz to 3 GHz R&SZRB2 0373.9017.5X ® SWR Bridge, 40 kHz to 4 GHz R&SZRC 1039.9492.5X High power attenuators ® 100 W, 3/6/10/20/30 dB, 1 GHz R&S RBU100 1073.8495.XX (XX = 03/06/10/20/30) ® 50 W, 3/6/10/20/30 dB, 2 GHz R&S RBU50 1073.8695.XX (XX = 03/06/10/20/30) ® 50 W, 20 dB, 6 GHz R&SRDL50 1035.1700.52 Connectors and cables ® ® N-type adapter for R&S RT-Zx probes R&SRT-ZA9 1417.0909.02 Probe power connector, 3 pin 1065.9480.00 DC blocks ® DC Block, 10 kHz to 18 GHz (type N) R&SFSE-Z4 1084.7443.02 ® ® External harmonic mixers (for R&S FSU26/43/46/50 with R&S FSU-B21 option) ® Harmonic Mixer 40 GHz to 60 GHz R&SFS-Z60 1089.0799.02 ® Harmonic Mixer 50 GHz to 75 GHz R&SFS-Z75 1089.0847.02 ® Harmonic Mixer 60 GHz to 90 GHz R&SFS-Z90 1089.0899.02 ® Harmonic Mixer 75 GHz to 110 GHz R&SFS-Z110 1089.0947.04 ® For R&S FSU26 only Test port adapter N male 1021.0541.00 Test port adapter 3.5 mm male 1021.0529.00 ® Microwave Measurement Cable with test R&SFSE-Z15 1046.2002.02 port adapter set N male and 3.5 mm male ® ® For R&S FSU43 and R&S FSU46 only Test port adapter N male 1036.4783.00 Test port adapter K male 1036.4802.00 ® Test port adapter 2.4 mm female R&SFSE-Z5 1088.1627.02 ® For R&S FSU50 only Test port adapter N male 1036.4783.00 Test port adapter K female 1036.4790.00 Test port adapter K male 1036.4802.00 ® Rohde & Schwarz R&S FSU Spectrum Analyzer 23 About Rohde & Schwarz Service you can rely on Rohde & Schwarz is an independent group of companies specializing in electronics. It is a leading supplier of solu- ❙ Worldwide ❙ Local and personalized tions in the fields of test and measurement, broadcasting, ❙ Customized and flexible radiomonitoring and radiolocation, as well as secure ❙ Uncompromising quality ❙ Long-term dependability communications. Established more than 75 years ago, Rohde & Schwarz has a global presence and a dedicated service network in over 70 countries. Company headquar- ters are in Munich, Germany. Environmental commitment ❙ Energy-efficient products ❙ Continuous improvement in environmental sustainability ❙ ISO 14001-certified environmental management system Certified Quality System ISO 9001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Regional contact ❙ Europe, Africa, Middle East | +49 89 4129 12345 customersupport@rohde-schwarz.com ❙ North America | 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com ❙ Latin America | +1 410 910 79 88 customersupport.la@rohde-schwarz.com ❙ Asia/Pacific | +65 65 13 04 88 customersupport.asia@rohde-schwarz.com ❙ China | +86 800 810 8228/+86 400 650 5896 customersupport.china@rohde-schwarz.com R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners | Printed in Germany (as) PD 0758.0016.22 | Version 16.01 | May 2012 | R&S®FSU Subject to change © 2004 -2012 Rohde & Schwarz GmbH & Co. KG | 81671 München, Germany 0758001622 FSU_dat-sw_en_0758-0016-22_v1601_cover.indd 2 22.05.2012 18:35:42

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the R&SFSU have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Measurement frequency range from 300 kHz to 8 & 20 GHz based on model configuration.

ATTENUATOR (R

HI POWER ATTENUATOR

HI POWER ATTENUATOR

product

Rohde & Schwarz RTO Series Oscilloscope