PRECISION DIGITAL PD6000-6R0
Datasheet
Extracted Text
duAl-lINe 6-dIGIt pRoCeSS MeteR r u P oV erieS S provu Model pd6000 • • 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V Inputs • NEMA 4X, IP65 Front • Universal 85-265 VAC or 12/24 VDC Input Power • Large Dual-Line 6-Digit Display, 0.6” & 0.46” • Isolated 24 VDC @ 200 mA Transmitter Power Supply • Math Functions for Flow & Round Horizontal Tanks • Programmable Displays & Function Keys • Sunlight Readable Display • 32-Point, Square Root, or Exponential Linearization • Multi-Pump Alternation Control • 2 or 4 Relays + Isolated 4-20 mA Output Options • External 4-Relay & Digital I/O Expansion Modules • RS-232, RS-422/485 Serial Communication Options • -40 to 65°C Operating Temperature Range www.predig.com Precision Digital corPoration provu Model pd6000 pRoCeSS MeteR • Large Sunlight 0.6" Digits Readable PV, Max/Peak, 6-Digit Min/Valley Dual-Line Programmable Display Function Keys Rugged Front NEMA 4X User Confi gurable (Actual Size) Status Indicators Display environmentally tough FeAtuRe RICH ANd FleXIBle The ProVu meter boasts specifi cations and functionality that clearly makes it one of the most advanced process meters available. Its dual-line 6-digit display (999,999), advanced UV Resistant math functions, function keys, and optional expansion modules Sunlight Readable NEMA 4X Rated are only a few of the features you will fi nd on the ProVu. FRoNt pANel dISplAY precise, Accurate, and More Informative ProVu’s large 0.6" main display will provide you with a highly accurate and precise six-digit view of your process. Its 24-bit A/D is accurate to 0.03% FS ±1 count. Rugged A unique front panel design makes the ProVu nearly impenetrable in typical applications. Here, the ProVu easily Confi gurable survives a direct hit on the display from The main display can be programmed to indicate PV, a heavy 2" solid stainless steel ball maximum (peak), minimum (valley), alternating maximum/ dropped from eight feet. minimum, or one of eight alarm set points. The secondary display can also be confi gured to display engineering units, user defi ned legends, or simply turned off. easy to use The user friendly dual-line display makes the ProVu easy Function Keys to set up & program. No jumpers to set, or potentiometers There are three function keys available to to adjust. All setup & the user. These keys can be programmed programming is done via the to trigger certain events (i.e. acknowledge front panel. Three levels of alarms, reset max and/or min, disable/enable password protection help output relays, or hold current relay states), maintain the reliability of the provide direct menu access points, and more. programming. 2 provu Model pd6000 pRoCeSS MeteR • MultI-puMp AlteRNAtIoN FIeld eXpANdABle optIoNS Up to 8 pumps can be alternated/sequenced. Add functionality to the ProVu in the field with easy- to-install external expansion modules. Add RS-232 or RS-422/485 communications, I/O modules (2), or 4-relay 1 expansion module. The menu items for these modules do not appear until the module is installed, simplifying the MENU basic menu. Shown here with optional DIN rail mounting Hi F1 Alarm kit, P/N PDA1002. F2 F3 Lo Alarm ON OFF Relay #4 turns the main pump on at 6000 gallons and turns it off at 1000 gallons. 2 MENU Hi F1 Alarm F2 F3 Lo Alarm OFF I/o expansion Module With the Pump Alternation feature activated, the next Four digital inputs and four digital outputs are available time the level reaches 6000 gallons, relay #3 transfers per expansion module. The ProVu meter will accept two and starts the backup pump. of these modules. External digital inputs can function similarly to the front panel function keys. They can be 3 configured to trigger certain events (i.e. acknowledge/reset alarms, reset max and/or min values, disable/enable all MENU Hi output relays, and hold current relay states), provide direct F1 Alarm F2 menu access point, or mimic front panel keys. F3 Lo Alarm Digital outputs can be used to remotely monitor ProVu’s alarm relay output states, or the states of a variety of actions and functions executed by the meter. If the backup pump is not able to keep up, and the level reaches 7000 gallons, relay #4 transfers and starts the main pump as well. Relay expansion Module An external module containing four 3 amp Form A (SPST) 4 relays can be added to the ProVu at anytime. Removable screw terminal blocks accept 12 to 22 AWG wire. MENU Hi F1 Alarm F2 F3 Lo Alarm Relay #2 trips the High Level Alarm at 7500 gallons and resets at 6900 gallons. 5 MENU Communications Module F1 F2 F3 Serial communications on the ProVu can be added anytime with external RS-232 or RS-422/485 communication adapters. Relay #1 trips the Low Level Alarm at 495 gallons and resets at 750 gallons. 3 provu Model pd6000 pRoCeSS MeteR • MAtH FuNCtIoNS outputS Non-linear input signals can be linearized with our Relay outputs simple to use built-in math functions, such as: square- root extractor, weirs & fl umes exponential linearizer, The ProVu has up to four 3 A Form C relays (SPDT), giving you more fail-safe options upon power loss. horizontal round tank linearizer, or our powerful general Relay action can also be confi gured for input loop break purpose 32-point linearizer (free linearization utility protection. Set ON and OFF delay times when needed. available at www.predig.com). Up to eight front panel indicators show alarm and/or relay state. Can be confi gured for 0-100% deadband. Relay operation/Confi guration There are powerful relay functions that can be confi gured in the ProVu meter, including: 4-20 mA signal • Automatic reset only (non-latching) • Automatic + manual reset at any time (non-latching) • Latching (manual reset only) • Latching with Clear (manual reset only after alarm condition has cleared) • Pump alternation control (automatic reset only) • Sampling (activated for a user-specifi ed time) Weirs and Flumes Math Function • User selectable fail-safe operation • Relay action for loss (break) of 4-20 mA input signal mA Out • Time delay (on and off), independent for each relay Relay 2 Relay 1 MENU Analog output 3 2 1 6 5 4 3 2 1 F1 F2 Loop-Powered Linearized + The isolated analog retransmission signal can be F3 Remote 4-20 mA output Indicator from ProVu confi gured to represent the process variable (PV), (Volume) – maximum (peak) value, minimum (valley) value, or the Hi 4-20 mA Output from Level Transmitter Alarm value for any of the eight relay set points. While the Level 4-20 mA Loop powered Transmitter by the ProVu meter output is nominally 4-20 mA, the signal will accurately Lo Alarm accommodate under- and over-ranges from 1 to 23 mA. Auto/Manual Control Take control of any output with this feature. All relays Round Horizontal Tank Math Function can be forced ON or OFF, and the 4-20 mA output signal can be set to any value within its range. Isolated transmitter power Supplies MeteR CopY A powerful 24 V @ 200 mA power supply is a standard The Copy feature is used to copy (or clone) all the feature on the ProVu meter. It can be confi gured for settings from one ProVu to other ProVu meters in about 5, 10, or 24 V (default) by means of a simple internal 20 seconds! The Copy function is a standard feature jumper (see manual). An additional power supply (24 V on all meters. It does not require a communications @ 40 mA) is standard with the 4-20 mA output option. adapter, only an optional cable assembly, P/N PDA1200. See the ordering information for complete details. NeMA 4 & 4X FIeld eNCloSuReS Plastic, stainless steel, and painted steel NEMA 4 enclosures for up to 10 ProVu meters. See our complete offering at www.predig.com/ProVu 4 provu Model pd6000 pRoCeSS MeteR • Environmental: Operating temperature range: -40 to 65°C. Storage CoNNeCtIoNS temperature range: -40 to 85°C. Relative humidity: 0 to 90% non-condensing. • Form C (SPDT) relays Connections: Removable screw terminal blocks accept 12 to 22 AWG • Two isolated supplies available even on 4-20 mA Output wire, RJ45 for external relays, digital I/O, and serial communication adapters. 12/24 VDC input power models Powered by PROVU Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black • Removable terminal blocks Mounting: 1/8 DIN panel cutout required: 3.622" x 1.772" • 2 or 4 relays + isolated 4-20 mA output option (92 mm x 45 mm). Two panel mounting bracket assemblies are provided. + - Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm) MA OUT RELAY4 RELAY3 RELAY2 RELAY1 Overall Dimensions: 4.68" x 2.45" x 5.64" 1 6 5 4 3 2 1 6 5 4 3 2 1 3 2 (119 mm x 62 mm x 143 mm) (W x H x D) NO NC COM NO NC COM NO NC COM NO NC COM I- I+ R Weight: 9.5 oz (269 g) 24 V UL File Number: UL & c-UL Listed. E160849; 508 Industrial Control Equipment. Warranty: 3 years parts & labor SIGNAL 1 2 3 4 5 6 7 8 P+ P- COM V+ mA+ - + process Input 1 2 3 4 5 1 2 Inputs: Field selectable: 0-20, 4-20 mA, ±10 VDC (0-5, 1-5, 0-10 V) M-LINK POWER Accuracy: ±0.03% FS ±1 count, square root & programmable exponent accuracy range: 10-100% FS • Universal 85-265 VAC or 12/24 VDC input power Temperature Drift: From 0 to 65°C ambient: 50 PPM/°C. • Voltage or current inputs + - From -40 to 0°C ambient: 100 PPM/°C. • No jumpers needed for V/mA input selection • M-Link for adding expansion modules Transmitter Math Function: Linear, square root, programmable exponent, or Powered by PROVU round horizontal tank volume calculation. Multi-Point Linearization: 2 to 32 points Programmable exponent: 1.0001 to 2.9999 Low-Flow Cutoff: 0-999999 (0 disables cutoff function) SpeCIFICAtIoNS Except where noted all specifications apply to operation at +25°C. Decimal Point: Up to five decimal places or none: d.ddddd, dd.dddd, ddd.ddd, dddd.dd, ddddd.d, or dddddd. General Calibration Range: Minimum span: 0.15 mA or 0.10 V. An Error Display: Main display: 0.6" (15 mm) high, red LED. Second display: 0.46" message will appear if input 1 and input 2 signals are too close together. (12 mm) high, red LED 6 digits (-99999 to 999999), lead zero blanking. Input Impedance: Voltage ranges: greater than 1 MΩ. Current Display Intensity: Eight intensity levels ranges: 50 - 100 Ω (depending on resettable fuse impedance). Display Update Rate: 5/second (200 ms) Input Overload: Current input protected by resettable fuse, 30 VDC max. Fuse resets automatically after fault is removed. Overrange: Display flashes 999999 Underrange: Display flashes -99999 Relays Front Panel: NEMA 4X, IP65 Programming Methods: Four front panel buttons, PC based Rating: 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) linearization utility, cloning using Copy function, or via digital inputs. external; rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP @ 125/250 VAC for inductive loads Noise filter: Programmable from 2 to 199 (0 will disable filter) Noise Suppression: Noise suppression is recommended for each Filter Bypass: Programmable from 0.1 to 99.9% FS relay contact switching inductive loads. Recalibration: Calibrated at the factory. Recalibration is Deadband: 0-100% FS, user programmable recommended at least every 12 months. High or Low Alarm: User may program any alarm for high or low trip Max/Min Display: Max (Peak)/min (Valley) readings reached by the point. Unused alarm LEDs and relays may be disabled (turned off). process are stored until reset by the user or until power to the meter Relay Operation: automatic (non-latching), latching (requires manual is turned off. acknowledge), sampling (based on time), and pump alternation Password: Three programmable passwords restrict modification of control (2 to 8 relays). programmed settings. Pass 1: Allows use of the F1–F3 function keys. Relay Reset: User selectable via front panel buttons or digital inputs. Pass 2: Allows use of the F1–F3 function keys and changing the set/ reset points. Pass 3: Restricts all programming and F1–F3 keys. 1. Automatic reset only (non-latching), when input passes the reset point. Note: Digital inputs are not password protected. 2. Automatic + manual reset at any time (non-latching). Non-Volatile Memory: All programmed settings are stored in non- 3. Manual reset only, at any time (latching). volatile memory for a minimum of ten years if power is lost. 4. Manual reset only after alarm condition has cleared (latching). Power Options: 85-265 VAC 50/60 Hz, 90-265 VDC 20 W max or Note: Front panel button or digital input may be assigned to 12/24 VDC ±10% (jumper selectable), 15 W max. acknowledge relays programmed for manual reset. Fuse: Required external fuse: UL Recognized, 5 A max, slow blow; up Time Delay: 0 to 999.9 seconds, on & off relay time delays. to 6 meters may share one 5 A fuse. Programmable and independent for each relay. Isolated Transmitter Power Supply: 5, 10, or 24 VDC selectable by Fail-Safe Operation: Programmable and independent for each relay. internal jumper. 24 VDC ± 5% supply rated @ 200 mA max (100 mA Note: Relay coil is energized in non-alarm condition. In case of power max for 12/24 VDC powered models). The 5 or 10 VDC supplies rated failure, relay will go to alarm state. @ 50 mA max. Auto Initialization: When power is applied to the meter, relays will Normal Mode Rejection: Greater than 60 dB at 50/60 Hz reflect the state of the input to the meter. Isolation: 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply. 5 NC NC provu Model pd6000 pRoCeSS MeteR • Isolated 4-20 mA transmitter output oRdeRING INFoRMAtIoN Output Source: Process variable (PV), max, min, or set points 1-8 Scaling Range: 1.000 to 23.000 mA for any display range ProVu • Model PD6000 Calibration: Factory calibrated: 4.000 to 20.000 = 4-20 mA output 85-265 VAC 12/24 VDC Options Installed Accuracy: ± 0.1% FS ± 0.004 mA Model Model Temperature Drift: 50 PPM/°C from 0 to 65°C ambient PD6000-6R0 PD6000-7R0 None Note: Analog output drift is separate from input drift. PD6000-6R2 PD6000-7R2 2 Relays (PD1102*) Isolated Transmitter Power Supply: Terminals I+ & R: 24 VDC ± 5% PD6000-6R3 PD6000-7R3 4-20 mA Output (PD1103*) @ 40 mA maximum, may be used to power the 4-20 mA output or other devices. Present on both AC & DC powered units. PD6000-6R4 PD6000-7R4 4 Relays (PD1104*) External Loop Power Supply: 35 VDC maximum PD6000-6R5 PD6000-7R5 2 Relays & 4-20 mA Out (PD1105*) Output Loop Resistance: PD6000-6R7 PD6000-7R7 4 Relays & 4-20 mA Out (PD1107*) Power supply Minimum Maximum 24 VDC 10 Ω 700 Ω Note: 24 V Transmitter power supply standard on all models. 35 VDC (external) 100 Ω 1200 Ω * Model number for replacement option board or field-installed options. Serial Communications Accessories Meter Address: 1 - 247 Model Description Baud Rate: 300 - 19,200 bps PDA1002 DIN Rail Mounting Kit for Two Expansion Modules Transmit Time Delay: Programmable between 0 and 199 ms or transmitter always on for RS-422 communication PDA1004 4-Relay Expansion Module Data: 8 bit (1 start bit, 1 stop bit) PDA1044 4 Digital Inputs & 4 Digital Outputs Module Parity: None PDA1200 Meter Copy Cable Turn Around Delay: Less than 2 ms (fixed) PDA1232 RS-232 Serial Adapter digital I/o expansion Module PDA1485 RS-422/485 Serial Adapter Channels: 4 digital inputs & 4 digital outputs per module PDA7485-I RS-232 to RS-422/485 Isolated Converter System: Up to 2 modules for a total of 8 inputs & 8 outputs PDA7485-N RS-232 to RS-422/485 Non-Isolated Converter Digital Input Logic: High: 3 to 5 VDC Low: 0 to 1.25 VDC PDA8232-N USB to RS-232 Non-Isolated Converter Digital Output Logic: High: 4.75 to 5 VDC Low: 0 to 0.4 VDC PDA8485-I USB to RS-422/485 Isolated Converter Source Current: 10 mA maximum Sink Current: 1.5 mA minimum PDA8485-N USB to RS-422/485 Non-Isolated Converter +5 V Terminal: To be used as pull-up for digital inputs only. PDX6901 Suppressor (snubber): 0.01 μF/470 Ω, 250 VAC 4-Relay expansion Module Relays: Four Form A (SPST) rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/4 HP @ 125/250 VAC for inductive loads. r u P oV MouNtING dIMeNSIoNS erieS S Optional Connector Installed 1.76" (45 mm) disclaimer The information contained in this document is subject to change without notice. Precision Digital 2.45" 4.17" Corporation makes no representations or warranties with respect to the contents hereof, and (62 mm) (106 mm) specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. ©2008 Precision Digital Corporation. All rights reserved. (121 mm) 3.61" 0.59" 4.77" (15 mm) (92 mm) 5.05" (128 mm) Your Local Distributor is: 6" (152 mm) Clearance 4.68" (119 mm) Side View Top View Notes: 1. Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 2. Panel thickness: 0.040 - 0.250" (1.0mm - 6.4mm) 3. Mounting brackets lock in place for easy mounting 4. Clearance: Allow 6" (152 mm) behind the panel LDS6000_AX13 01/08 Precision Digital corPoration www.predig.com 19 Strathmore Road • Natick MA 01760 USA • Tel (800) 343-1001 • Fax (508) 655-8990 C C NO NO
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the PD6000-6R0 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods