Specifications
Bump
IEC/EN 60068-2-29, 11 ms; 25 gn
Current limitation
rectangular U/I characteristic; 101 to 112% Io nom
Damp heat
IEC/EN 60068-2-3, 93%, 40°C, 56 days
Degree of protection
IP 20
Electric strength test voltage
class I, I/case 2 kV AC; class I, I/O 3 kV AC; class I, O/case 1 kV AC; class I, O/O 0.35 kV AC
EMC
Electrostatic discharge:IEC/EN 61000-4-2, level 4, contact/air (8/15 kV) criterion A; Electromagnetic field:IEC/EN 61000-4-3, level 3 (10 V/m) criterion A; Electr. fast transients/bursts:IEC/EN 61000-4-4, level 4, capacitive/direct (4/2 kV) criterion A; Surge:IEC/EN 61000-4-5, level 3, in and out, line to line (2 kV), criterion B, level >3, input, line to case (3.5 kV), criterion B, level 2, output, line to case (1 kV), criterion A; Conducted disturbances:IEC/EN 61000-4-6, level 3 (10 V), criterion A; Electromagnetic emissions:CISPR 22/EN 55022, conducted, class A
Hold-up time
Io nom, Uo decreases to 80% of Uo nom typ. 15 ms
Input frequency
14 to 440 Hz
Input fuse
not user accessible 6.3 A, slow blow
Input overvoltage lockout
typ. 105% Ui max
Input reverse polarity
bridge rectifier
Input transient protection
voltage depending resistor (VDR)
Input undervoltage lockout
typ. 80% Ui min
Input voltage
world wide mains, single phase; 85 to 264 V AC; derating information see application note; 90 to 350 V DC
Inrush current
virtually no inrush current
Line and cross regulation
Ui min to Ui max; typ. 50 mV
Load regulation
0 to 100% Io nom, Ui nom; –1.6% Uo nom
Minimum load
not required
MTBF
MIL-HDBK-217E, GB, 40°C, >600,000 h
Operating ambient temperature
Ui nom, Io nom, convection cooled; –40 to 60°C
Operating case temperature Tc
Ui nom, Io nom, –40 to 87°C
Operation in parallel
enabled by droop current share
Output Efficiency
Ui nom, Io nom; up to 89%
Output overvoltage
second control loop, each output, 24 V/48 V; 30/60 V SELV
Output voltage noise
IEC/EN 61204; typ. 50 mV
Output voltage ripple
sinusoidal output ripple at wice the line frequency =1.2 Vpp
Output voltage setting accuracy
Ui nom, Io nom; ± 1.3% Uo nom
Output(s)
no-load, overload and short circuit proof
Overtemperature
reduced output power if thermally overloaded
Pollution degree
AC-in / DC-in 3/2
Power factor
active PFC; up to 0.99
Safety Approvals
EN 60950, UL 1950, CSA22.2 No. 950, UL 508 listed
Shock
IEC/EN 60068-2-27, 11 ms; 50 gn
Shock and vibration
unit wall mounted with brackets
Short term peak power
1 s, electronically controlled; 150% Io nom
Status indication
LED output(s) OK
Storage temperature
non operational, –40 to 100°C
Vibration, random
IEC/EN 60068-2-64, 20 to 500 Hz, 0.05 g2/Hz
Vibration, sinusoidal
IEC/EN 60068-2-6, 10 to 60/60 to 2000 Hz, 0.35 mm/5 gn
Datasheet
Extracted Text
W Series 125 and 250 Watt AC-DC Converters Input range 85...264 V AC with PFC 1 or 2 isolated, regulated outputs up to 96 V 3 kV AC I/O electric strength test voltage LGA • Electrically and mechanically rugged DIN-rail front end • Outputs individually controlled with 150% output peak power • Operating ambient temperature range –40...60°C with convection cooling Selection chart for front ends 1 Output 1 Output 2 Input voltage Rated power Type Options U I U I U U T = 60°C o nom o nom o nom o nom i min i max A [V DC] [A] [V DC ] [A] P [W] o tot 24.7 5 - - 125 LWR-1601-6 R 24.7 10 - - 250 LWN-1601-6 D1…D5 37 3.3 - - 85...264 VAC 125 LWR 1701-6 S 3 37 6.6 - - (14…440 Hz) 250 LWN 1701-6 M2 49.4 2.6 - - 90…350 VDC 125 LWR 1801-6 F, F1 49.4 5 - - 250 LWN-1801-6 K2 24.7 5 24.7 5 250 LWN-2660-6 49.4 2.5 49.4 2.5 250 LWN 2880-6 Selection chart for battery chargers 1 Output Input voltage Rated power Type Options U I U U T = 60°C o nom o nom i min i max A [V DC] [A] P [W] o tot 25.7...29.3 4.2 85…264 VAC 115 LWR 1240-6 M1 F, F1 25.7...29.3 8.45 3 230 LWN 1240-6 M1 K2 (14…440 Hz) 51.4...58.6 2.1 90…350 VDC 115 LWR 1740-6 M1 51.4...58.6 4.2 230 LWN 1740-6 M1 1 For lead times and minimum order quantity contact Power-One. 2 For availability contact Power-One. 3 Input frequency range certified for 14...440 Hz. For continuous operating frequency <40 Hz and >100 Hz contact factory. www.power-one.com Edition 5/07.2001 1 W Series 125 and 250 Watt AC-DC Converters Input Input voltage world wide mains, single phase 85...264 V AC derating information see application note 90...350 V DC Input frequency 14...440 Hz Power factor active PFC up to 0.99 Inrush current virtually no inrush current Output Efficiency U , I up to 89% i nom o nom Output voltage setting accuracy U , I ± 1.3% U i nom o nom o nom Output voltage noise IEC/EN 61204 typ. 50 mV Output voltage ripple sinusoidal output ripple at wice the line frequency ≤1.2 V pp Line and cross regulation U ...U typ. 50 mV i min i max Load regulation 0...100% I , U –1.6% U o nom i nom o nom Minimum load not required Current limitation rectangular U/I characteristic 101...112% I o nom Short term peak power 1 s, electronically controlled 150% I o nom Operation in parallel enabled by droop current share Hold-up time I , U decreases to 80% of U typ. 15 ms o nom o o nom Control Status indication LED output(s) OK Protection Input fuse not user accessible6.3 A, slow blow Input reverse polarity bridge rectifier Input undervoltage lockout typ. 80% U i min Input overvoltage lockout typ. 105% U i max Input transient protection voltage depending resistor (VDR) Output(s) no-load, overload and short circuit proof Output overvoltage second control loop, each output, 24 V/48 V 30/60 V SELV Overtemperature reduced output power if thermally overloaded Safety Approvals EN 60950, UL 1950, CSA22.2 No. 950, UL 508 listed Electric strength test voltage class I, I/case 2 kV AC class I, I/O 3 kV AC class I, O/case 1 kV AC class I, O/O 0.35 kV AC Pollution degree AC-in / DC-in 3/2 Degree of protection IP 20 www.power-one.com Edition 5/07.2001 2 DIN Rail Mountable W Series EMC Electrostatic discharge IEC/EN 61000-4-2, level 4, contact/air (8/15 kV) criterion A Electromagnetic field IEC/EN 61000-4-3, level 3 (10 V/m) criterion A Electr. fast transients/bursts IEC/EN 61000-4-4, level 4, capacitive/direct (4/2 kV) criterion A Surge IEC/EN 61000-4-5, level 3, in and out, line to line (2 kV) criterion B level >3, input, line to case (3.5 kV) criterion B level 2, output, line to case (1 kV) criterion A Conducted disturbances IEC/EN 61000-4-6, level 3 (10 V) criterion A Electromagnetic emissions CISPR 22/EN 55022, conducted class A Environmental Operating ambient temperature U , I , convection cooled –40...60°C i nom o nom Operating case temperature T U , I –40...87°C C i nom o nom Storage temperature non operational –40...100°C Damp heat IEC/EN 60068-2-3, 93%, 40°C 56 days Shock and vibration unit wall mounted with brackets Shock IEC/EN 60068-2-27, 11 ms 50 g n Bump IEC/EN 60068-2-29, 11 ms 25 g n Vibration, sinusoidal IEC/EN 60068-2-6, 10...60/60...2000 Hz 0.35 mm/5 g n 2 Vibration, random IEC/EN 60068-2-64, 20...500 Hz 0.05 g /Hz MTBF MIL-HDBK-217E, G , 40°C >600'000 h B Options Input and output undervoltage monitoring D1...D5 Output voltage adjustment 10 V...110% of U R o nom Remote on/off S Multi option choice (D1...D5, R, S) via Sub-D connector M1...M2 Built-in second input fuse in the neutral F No fuse fittet (for operation from high DC) F1 System connectors with screw terminals K2 www.power-one.com Edition 5/07.2001 3 W Series 125 and 250 Watt AC-DC Converters Mechanical data Tolerances ±0.3 mm (0.012") unless otherwise indicated. European Projection 118 (4.65") 113.6 (4.47") 105 (4.15") 106.6 (() 4.2") 103 (4.05") 29.4 (1.16") 09107 T C Wall mounting brackets (accessory) Option M 31 (1.22") T T T T A A A Measuring point for case temperature T C www.power-one.com Edition 5/07.2001 4 138 (5.43") 5 15 (0.59") 13 (0.51") 1 43 (1.69") 33 (1.3") 49 (1.93") DIN Rail Mountable W Series Terminal allocation input side S10066 Pin Des. Determination 1 Protective earth 2N Input neutral 1 2 3 3P Input phase Terminal allocation output side S10067 Pin Des. Single output Double output 1 Earth to load Earth to load 2 + Output pos. Output 1 pos. 1 235 4 6 7 8 9 10 11 3 + Output pos. Output 1 pos. 4 – Output neg. Output 1 neg. 5 – Output neg. Output 1 neg. 6 + Output pos. Output 2 pos. 7 + Output pos. Output 2 pos. 8 – Output neg. Output 2 neg. 9 – Output neg. Output 2 neg. 10 Aux. Options Options 11 Earth to load Earth to load Accessories Mounting brackets for vertical chassis/wall mounting Fixing brackets for enhanced vibrations on DIN-rail Protective covers over input and output terminals www.power-one.com Edition 5/07.2001 5 This datasheet has been download from: www.datasheetcatalog.com Datasheets for electronics components.
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the LWN1601-6 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
Related Products

Power-One MAP40-3500 Power Supply - AC/DC switching power supply, 40 watt; triple output voltage 1 i...

Power One MPU150-4000 - Power Supply | AC Input | Multiple Output | 150W with 300 LFM forced air coo...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods