POWER-ONE LH1301-2R
Specifications
Cross load regulation outp. 2, 3
0 - 100% Io1 nom typ. 0.7 V
Current limitation aux. output(s)
rectangular U/I characteristic typ. 120% Io nom
Current limitation main output
rectangular U/I characteristic typ. 110% Io nom
Efficiency
Vi nom, Io nom up to 83%
Hold-up time
Vi 230 V AC, Io nom typ. 70 ms
Input frequency
47 - 63 Hz
Input voltage
continuous range 85 - 255 V AC
Inrush current limitation
by thermistor
Line regulation
Vi min - Vi max, Io nom typ. ±1% Vo nom
Load regulation output 1
Vi nom, 0 - Io1 nom typ. 0.2% Vo1 nom
Load regulation output 2, 3
10 - 100% Io2,3 nom typ. 0.7 V
Minimum output current
not required 0 A
Operation in parallel
by current limitation
Output voltage 1 setting acc.
Vi nom, Io nom ±2% Vo1 nom
Output voltage 2, 3
Vi nom, Io1 nom, Io2,3
Output voltage 2, 3 setting acc.
Vi nom, Io nom ±5% Vo2,3 nom
Output voltage switching noise
IEC/EN 61204, total typ. 200 mVpp
Datasheet
Extracted Text
H Series Data Sheet 50 Watt AC-DC Converters Input voltage range 85 to 255 V AC 1, 2 or 3 isolated outputs up to 48 V DC Class I equipment LGA • Rugged electrical and mechanical design Output 1 regulated, outputs 2 and 3 tracking Operating ambient temperature range –10 to 50°C with convection cooling Model Selection Output 1 Output 2 Output 3 Rated power Type Options V I V I V I P Input voltage o nom o nom o nom o nom o nom o nom o tot [V DC] [A] [V DC] [A] [V DC] [A] [W] 85 - 255 V AC 5.1 11 - - - - 56 LH 1001-2R D, V 12 6 - - - - 72 LH 1301-2R D 15 4.5 - - - - 67 LH 1501-2R D 24 3 - - - - 72 LH 1601-2R D 48 1.5 - - - - 72 LH 1901-2R D 12 2 12 2 - - 48 LH 2320-2 D 15 1.7 15 1.7 - - 51 LH 2540-2 D 5.1 5 12 0.7 12 0.7 42 LH 3020-2 D, V 5.1 5 15 0.6 15 0.6 43 LH 3040-2 D, V Input Input voltage continuous range 85 - 255 V AC Input frequency 47 - 63 Hz Inrush current limitation by thermistor Output Efficiency V , I up to 83% i nom o nom Output voltage 1 setting acc. V , I ±2% V i nom o nom o1 nom Output voltage 2, 3 setting acc. V , I ±5% V i nom o nom o2,3 nom Output voltage switching noise IEC/EN 61204, total typ. 200 mV pp Line regulation V - V , I typ. ±1% V i min i max o nom o nom Load regulation output 1 V , 0 - I typ. 0.2% V i nom o1 nom o1 nom Load regulation output 2, 3 10 - 100% I typ. 0.7 V o2,3 nom Output voltage 2, 3 V , I , I = 0 max. 115% V i nom o1 nom o2,3 o2,3 nom Cross load regulation outp. 2, 3 0 - 100% I typ. 0.7 V o1 nom Minimum output current not required 0 A Current limitation main output rectangular U/I characteristic typ. 110% I o nom Current limitation aux. output(s) rectangular U/I characteristic typ. 120% I o nom Operation in parallel by current limitation Hold-up time V = 230 V AC, I typ. 70 ms i o nom REV. JAN 8, 2004 Page 1 of 4 H Series Data Sheet 50 Watt AC-DC Converters Protection Input undervoltage lockout typ. 60 V AC Input overvoltage lockout typ. 280 V AC Input transient protection varistor Output no-load, overload and short circuit proof Output overvoltage suppressor diode in each output typ. 150% V o nom Overtemperature switch-off with auto restart T typ. 100°C C Control Output voltage adjustment single output types 0 - 110% V o1 nom Inhibit TTL input, output(s) disabled if left open-circuit Status indication LEDs: OK, inhibit Safety Approvals EN 60950, UL 1950, CSA C22.2 No. 950 Class of equipment class I Protection degree units without options IP 40 Electric strength test voltage I/case 2 kV AC I/O 4 kV AC O/case 1 kV AC O/O 0.2 kV AC EMC Electrostatic discharge IEC/EN 61000-4-2, contact discharge, level 2 (4 kV) criterion A Electromagnetic field IEC/EN 61000-4-3, level x (20 V/m) criterion A Electr. fast transients/bursts IEC/EN 61000-4-4, input, level 1 (0.5 kV) criterion A Surge IEC/EN 61000-4-5, input, level 1 (0.5 kV) criterion A Electromagnetic emissions CISPR 22/EN 55022, conducted class A CISPR 22/EN 55022, radiated class B Environmental Operating ambient temperature V , I , convection cooled –10 to 50°C i nom o nom Operating case temperature T V , I –10 to 80°C C i nom o nom Storage temperature non operational –25 to 100°C Damp heat IEC/EN 60068-2-3, 93 %, 40 °C 21 days Vibration, sinusoidal IEC/EN 60068-2-6, 10 - 60/60 - 150 Hz 0.15 mm/2 g n Shock IEC/EN 60068-2-27, 6 ms 15 g n Bump IEC/EN 60068-2-29, 16 ms 10 g n MTBF MIL-HDBK-217E, G , 40 °C, single output types 384'000 h B Options Input and/or output undervoltage monitoring, excludes option V D1- D8 Input and/or output undervoltage monitoring (VME), excludes option D V2, V3 REV. JAN 8, 2004 Page 2 of 4 H Series Data Sheet 50 Watt AC-DC Converters Mechanical data Tolerances ±0.3 mm (0.012") unless otherwise indicated. European Projection 2 5 8 11 14 17 20 23 26 29 32 M 3; depth = 4 mm (chassis mount) Measuring point for case temperature T C 22 (0.87") 38.7 (1.52") 103 111.2 (3U) (4.38") OK Potentiometer Inhibit i (option D or V) REV. JAN 8, 2004 Page 3 of 4 168.5 (6.63") 2TE 20 (0.79") 6TE 127 (5") 68 S09050 173.7 (6.84") H Series Data Sheet 50 Watt AC-DC Converters Pin allocation Pin Electrical Determination LH1000 LH2000 LH3000 2 Inhibit control input i i i 5 Safe Data or ACFAIL D or V D or V D or V 8 Output voltage (positive) Vo1+ Vo3+ 11 Output voltage (negative) Vo1– Vo3– 14 Control input + R 17 Control input – G 14 Output voltage (positive) Vo2+ Vo2+ 17 Output voltage (negative) Vo2– Vo2– 20 Output voltage (positive) Vo1+ Vo1+ Vo1+ 23 Output voltage (negative) Vo1– Vo1– Vo1– 26 Protective earth 29 AC input voltage N N N 32 AC input voltage P P P Accessories Front panels 19" (Schroff/Intermas) Mating H11 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Flexible PCB for connecting the converter via an H11 connector, if mounted on a PCB Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support sys- tems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective di- visional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depend- ing on the date manufactured. Specifications are subject to change without notice. REV. JAN 8, 2004 Page 4 of 4
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the LH1301-2R have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods