Elite.Parts chervon right Manufacturers chervon right P chervon right PANASONIC chervon right LH-54
About product Specifications Features Datasheet FAQ

PANASONIC LH-54

Image of PANASONIC LH-54

Description

Panasonic LH-54 Sensor - LED DISPLACEMENT, 1.6MM SPOT(40+/-10MM),2MICRO

Part Number

LH-54

Price

Request Quote

Manufacturer

PANASONIC

Lead Time

Request Quote

Category

PRODUCTS - L

Specifications

Ambient Humidity

35 to 85 % RH, Storage: 35 to 85 % RH

Ambient Temperature

0 to + 45 °C + 32 to + 113 °F (No dew condensation), Storage: - 20 to + 60 °C + 4 to +140 °F

Applicable controller

LH-CL6(P), LH-CS6(P), LH-CD6(P)

Cable

0.22 mm2 11-core composite cabtyre cable, 0.2 m 0.656 ft long, with a connector at the end

Cable extension

Extension up to total 10.2 m 33.465 ft is possible, with optional cable

Emitting element

Red LED (modulated)(Peak wavelength: 650 nm 0.026 mil)

Linearity (Note 4)

Within ±0.2 % F.S.

Measurement center distance

40 mm 1.575 in

Measuring Range

±10 mm (30 to 50 mm) ±0.394 in (1.181 to 1.969 in)

Protection

(excluding connector part) IP67 (IEC)

Spot diameter (Note 2)

ø3.0 mm ø0.018 in or less

Weight

70 g approx. (including cable), 45 g approx. (excluding cable)

Features

Datasheet

pdf file

Panasonic-lh-50-datasheet-409719153.pdf

628 KiB

Extracted Text

LH-50 SERIES LED Type Optical Displacement Sensor Minute displacements measured with high precision by red �� � LED beam Conforming to UL Recognition EMC Directive Safety precautions unnecessary Reducing total cost Compact and lightweight The light source uses a red LED for The high-functional controller includes Sensor head safety. built-in calculation and measurement Compared to our previous sensors, the As a result, the complicated safety functions, so that the digital panel LH-50 series sensors are much more measures which are necessary when controller which was needed previously compact and lightweight, so that they using laser light are completely is no longer required, thus reducing can easily be installed even in tight unnecessary. costs. spaces. Even though a In addition, it also helps to reduce 24 mm red LED is used, wiring and space costs. 72 mm 0.945 in the degree of 2.835 in 17 mm 46 mm 0.669 in 1.811 in performance achieved is the 46 mm Not 1.811 in 75 mm same as for needed 2.953 in laser-type sen- sor class (Class Optical shield LH-50 series 1 to 2), so that Previous product high-precision Laser-type displacement measurement is sensor Not needed Controller possible. The general purpose controller is the Digital panel controller LH-CS6(P) most compact in its class. Furthermore, the high-functional Universal use controller is a �48 mm �1.890 in panel mounting type which can be The LH-50 series complies with EMC mounted on equipment panels. directive for the CE marking. 67 mm It uses an LED beam which is not 2.638 in subject to FDA restrictions. In addition, it obtains UL recognition. 40 mm 1.575 in 26 mm 1.024 in General purpose controller (DIN rail mounting type) UL Recognition 77.5 mm Conforming to EMC Directive 3.051 in 48 mm 1.890 in 48 mm 1.890 in High-functional controller Panel mounting (Panel mounting type) 904 GP-A GP-X LD LA LA-300 HL-T1 LM10 LH-50 HL-C1 MEASUREMENT SENSORS Magnetic Displacement Light / Thru-beam Type Light / Reflective Type LH-50 Simple and useful • Uses an easy-to-operate jog switch • Full range of ‘ready-to-use’ and ‘useful’ functions General purpose controller High-functional controller Threshold value settings and other The high-functional controller is equipped with useful Press settings can be made easily using the calculation functions, so that the digital panel controller Turn extremely easy-to-operate jog switch. which was needed previously is no longer required. Furthermore, the settings and measurement values are indicated in a 5-digit LED display. 5-digit LED display examples Digital panel controller not (Example of measurement value) (Example of settings) needed LH-CD6(P) Digital panel controller • Flexible combinations Calculation, level difference and thickness measurements and Sensor head General purpose controller High-functional controller displacement from the measuring center when using a single The LH-50 series can be used in any combination desired. sensor head are set to default settings, so that the unit can be In addition, the sensor head and controller need not be used immediately. managed as a pair. Level difference measurement (A B) Thickness measurement L – (A�B) � Moreover, the LH-CD6(P) high-functional controller can be connected to two sensor heads of different types. L Select by center measuring

Error Message

Error Message

Your contact information

Error Message

Error Message

Error Message

Error Message

Your company / organization

Error Message

Error Message

Your requirement

Error Message

Error Message

Error Message

By sending us your information, you agree to our Privacy Policy

You will not receive unsolicited communications

The quote request has been received