Safety Light Curtain
F3S-B
Safety Design for Category 2.
Suitable for
Detecting Human
Bodies in a
Dangerous Area
Features
The F3S-B is a type 2 Safety Light curtain intended to be
used as or with the safety related parts of the control system
of a machine to category 2, 1 or B as defined in the Europe-
an standard EN954-1.
Compliance with IEC 61496-2, EN 61496-1 standards and
machine and EMC directive.
Received certificates from Notified Bodies as Type 2 ESPE
(Electro-Sensitive-Protective-Equipment).
UL/CSA approved.
Pursuing safety with high level of safety design and FMEA.
Series configuration of two units is possible.
Units available with an axis pitch of 25 mm (hand protec-
tion), 50 mm (arm protection) or 75 mm (body protection) in
protective height ranging from 300 mm to 1650 mm.
Human body detection system without a dedicated control
box.
M12 Connector
F3S-B G-31
F3S-B
F502-EN2-04.book Seite 32 Dienstag, 26. Juli 2005 5:48 17
Ordering Information
F3S-B M 36 2 P 12 - L
blank Stand-alone blank Complete set of emitter and receiver
M Master unit for series connection L Emitter unit only
S Slave unit for series connection D Receiver unit only
36 No. of optical axis (4-66) blank Stand-alone or slave unit
12 No. of optical axis of the connected slave unit
2 25 mm optical pitch
for 25 mm optical pitch type: 12, 18, 24, or 30
5 50 mm optical pitch
for 50 mm optical pitch type: 06, 09, 12, or 15
7 75 mm optical pitch
for 75 mm optical pitch type: 04, 06, 08, or 10
blank Slave unit
P PNP outputs
Stand-alone Master unit Slave unit Optical No. of Protective height Weight (without
resolution optical axes accessories)
F3S-B122P F3S-BM122P## F3S-BS122 30 mm 12 300 mm 0.9 kg
F3S-B182P F3S-BM182P## F3S-BS182 18 450 mm 1.2 kg
F3S-B242P F3S-BM242P## F3S-BS242 24 600 mm 1.5 kg
F3S-B302P F3S-BM302P## F3S-BS302 30 750 mm 1.8 kg
F3S-B362P F3S-BM362P## - 36 900 mm 2.1 kg
F3S-B422P F3S-BM422P## - 42 1,050 mm 2.5 kg
F3S-B482P F3S-BM482P## - 48 1,200 mm 2.8 kg
F3S-B542P F3S-BM542P## - 54 1,350 mm 3.1 kg
F3S-B602P F3S-BM602P## - 60 1,500 mm 3.4 kg
F3S-B662P F3S-BM662P## - 66 1,650 mm 3.7 kg
F3S-B065P F3S-BM065P## F3S-BS065 55 mm 6 300 mm 0.9 kg
F3S-B095P F3S-BM095P## F3S-BS095 9 450 mm 1.2 kg
F3S-B125P F3S-BM125P## F3S-BS125 12 600 mm 1.5 kg
F3S-B155P F3S-BM155P## F3S-BS155 15 750 mm 1.8 kg
F3S-B185P F3S-BM185P## - 18 900 mm 2.1 kg
F3S-B215P F3S-BM215P## - 21 1,050 mm 2.5 kg
F3S-B245P F3S-BM245P## - 24 1,200 mm 2.8 kg
F3S-B275P F3S-BM275P## - 27 1,350 mm 3.1 kg
F3S-B305P F3S-BM305P## - 30 1,500 mm 3.4 kg
F3S-B335P F3S-BM335P## - 33 1,650 mm 3.7 kg
F3S-B047P F3S-BM047P## F3S-BS047 80 mm 4 300 mm 0.9 kg
F3S-B067P F3S-BM067P## F3S-BS067 6 450 mm 1.2 kg
F3S-B087P F3S-BM087P## F3S-BS087 8 600 mm 1.5 kg
F3S-B107P F3S-BM107P## F3S-BS107 10 750 mm 1.8 kg
F3S-B127P F3S-BM127P## - 12 900 mm 2.1 kg
F3S-B147P F3S-BM147P## - 14 1,050 mm 2.5 kg
F3S-B167P F3S-BM167P## - 16 1,200 mm 2.8 kg
F3S-B187P F3S-BM187P## - 18 1,350 mm 3.1 kg
F3S-B207P F3S-BM207P## - 20 1,500 mm 3.4 kg
F3S-B227P F3S-BM227P## - 22 1,650 mm 3.7 kg
G-32 Safety Sensors / Components
F502-EN2-04.book Seite 33 Dienstag, 26. Juli 2005 5:48 17
Nomenclature
Protective height Series connection types
The F3S-B can detect in the area indicated by ”Protective When your application requires an additional protective zone,
height” in the figure below. The protective height is from ”the for example, to prevent someone from staying behind a pri-
Optical-axis line mark above the indicator area” to ”the end of mary detection zone, the F3S-B may be connected in series.
the yellow metal case”. The system consists of a master unit, a slave unit, and a se-
ries connection cable, type F39-JB1B.
The series connection allows up to 96 axes and 2.4 m of pro-
Optical-axis line mark
The center line for optical axes is indicated by the triangle
tective height in total.
mark. This position is a reference line for measuring safety
Series connection types have the same characteristics as a
distance.
stand-alone types. When the detection zone of the master
Optical resolution
No.ofopticalaxes
unit or that of the slave unit is interrupted, the outputs of the
n
master unit go to the OFF-state.
n-1 Limit position
Protective for detection
height
2
1
Optical- axis
pitch
Detection distance
Optical- axis
Protective
line mark
height
Slave unit
Stand-alone type
This is the most common configuration, and it is used to pro-
tect a hazardous part of a machine when approached from
one direction only.
Receiver
Series connection cable
Emitter
Protective
height
Protective Master unit
height
Indicator area
Indicator area
Extension cable
Note: Slave unit does not have indicators.
Extension cable
Master unit and slave unit need to be ordered separately.
F3S-B G-33
Emitter
Receiver
F3S-B
F502-EN2-04.book Seite 34 Dienstag, 26. Juli 2005 5:48 17
Rating and Performance
*1 *1 *1
F3S-B###P F3S-BM###P## F3S-BS###
Type
Stand-alone Master unit for series connection Slave unit for series connection
No. of optical axes 12 to 66 6 to 33 4 to 22 12 to 66 6 to 33 4 to 22 12 to 30 6 to 15 4 to10
Optical-axis pitch 25 mm 50 mm 75 mm 25 mm 50 mm 75 mm 25 mm 50 mm 75 mm
Optical resolution Non-transparent: in diameter
(Detection capability)
30 mm 55 mm 80 mm 30 mm 55 mm 80 mm 30 mm 55 mm 80 mm
Protective height 300 / 450 / 600 / 750 / 900 / 1,050 / 1,200 / 1,350 / 1,500 / 300 / 450 / 600 / 750 mm
1,650 mm
Detection distance 0.3 to 5.0 m, up to 8 m on request
Response time ON to OFF: See table “Response Time”
*2
OFF to ON : Default 100 ms (selectable with F39-U1E, 80 to 400 ms)
Startup waiting time 2 s max.
Supply voltage: Vs 24 VDC ± 20% (including 5 Vp-p ripple)
Current 400 mA max. (under no-load conditions)
consumption
Light source Infrared LED (880 nm wavelength). Lifetime: 50,000 hrs. at 25 °C.
Effective aperture angle Within ± 5° for the emitter and receiver at a detection distance of at least 3 m according to IEC
61496-2
Operating mode Light ON
Control output Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for volt-
age drop due to cable extension)
Instability output PNP transistor output (not safety-related control output),
activated during an insufficient light detection, failure detection and connection with F39-E1,
load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to cable exten-
sion)
Protection circuit Output short-circuit protection, power supply reverse connection protection
Start/restart Mode selection before power ON by connecting ”Interlock selection input” line to:
interlock function Active: No connection or 0 to 2.5 VDC, 3 mA max.
Inactive: Instability output line
Reset of start/restart interlock by connecting ”Interlock selection input” line to:
Interlock reset: 17 VDC to Vs, 20 mA max. Duration time 15 to 2,500 ms
External test function Mode selection by connecting ”External test input” line to:
Active: 17 VDC to Vs, 10 mA max. Duration time at least 15 ms
Inactive: No connection or 0 to 2.5 VDC, 2 mA max.
Relay monitoring Default inactive, selectable with F39-U1E
function (optional) Relay monitoring input line with NC contact connected,
Available level: 17 VDC to Vs, 10 mA max.
*3
Allowed relay delay time : Selectable between 20 and 300 ms
Termination when not selected: No connection or 0 to 2.5 VDC, 2 mA max.
Start interlock function Default inactive, selectable with F39-U1E
(optional)
Blanking function Default inactive, selectable with F39-U1E
(optional)
Indicator See ”Indicators” No indicators
Connection method For Extension cable: 8 pins, M12 connector
For Series connection cable: 6 pins, M12 connector
Ambient temperature During operation: –10 to 55 °C (with no freezing)
During storage: –25 to 70 °C
Ambient humidity During operation: 35 to 85 %RH (with no condensation)
During storage: 35 to 95 %RH
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength voltage 1,000 VAC 50/60 Hz for 1 min
Degree of protection IEC60529 IP65
Vibration resistance Normal operation: 10 to 55 Hz, double-amplitude: 0.7mm, X, Y and Z directions 20 sweeps
2
Shock resistance Normal operation: 100 m/s [10 G], X, Y and Z directions: 1000 times
Materials Case: Aluminum
Front cover: PMMA (acrylic resin)
End caps: PA6
Size (cross section) 30 x 40 mm
G-34 Safety Sensors / Components
F502-EN2-04.book Seite 35 Dienstag, 26. Juli 2005 5:48 17
*1 *1 *1
F3S-B###P F3S-BM###P## F3S-BS###
Type
Stand-alone Master unit for series connection Slave unit for series connection
*3 *4
Accessories Test rod , mounting brackets (top and bottom), mounting brackets (intermediate) , mounting
*5 *5
plates , Instruction manual
Applicable standard IEC(EN)61496-1 TYPE 2 ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2 TYPE 2 AOPD (Active Opto-electronic Protective Devices)
Note: 1 .For detailed type names and optical specifications, see „Type Naming Rule“
2 .Nominal value (set time). The accuracy is -0 ... +70% of the ON to OFF response time.
3 .Only with F3S-B###2P and BM###2P##.
4 .For the 1,050 mm protective height and longer types.
5 .Only with F3S-B###P# and BM##2P##.
Indicators
Optical- axis
line mark
IR-power indicator ON-state indicator
(Orange) (Green)
POWER ON
INTER-
Interlock indicator
OFF-state indicator
OFF
LOCK
(Yellow)
(Red)
EXT.TEST
UNSTAB
BLANKING
External test /
Instability indicator
blanking indicator
(Orange)
(Green)
Emitter IR-power indicator: Lit when emitting.
Interlock indicator: Lit during start/restart interlock or start interlock.
External test/ blanking indicator: Lit during external test. / Flashing when using blanking function.
Receiver ON-state indicator: Lit when receiving light.
OFF-state indicator: Lit with interrupted light.
Flashing during connection with F39-E1 or with failure.
Instability indicator: Lit with an insufficient light reception or failure.
Flashing during connection with F39-E1.
F3S-B G-35
F3S-B
F502-EN2-04.book Seite 36 Dienstag, 26. Juli 2005 5:48 17
Table of Response Time
Stand-alone type
Response time [ms ] Response time [ms ] Response time [ms ]
F3S-B122P 20 F3S-B065P 20 F3S-B047P 20
F3S-B182P 20 F3S-B095P 20 F3S-B067P 20
F3S-B242P 20 F3S-B125P 20 F3S-B087P 20
F3S-B302P 23 F3S-B155P 20 F3S-B107P 20
F3S-B362P 27 F3S-B185P 20 F3S-B127P 20
F3S-B422P 30 F3S-B215P 21 F3S-B147P 20
F3S-B482P 34 F3S-B245P 22 F3S-B167P 20
F3S-B542P 37 F3S-B275P 24 F3S-B187P 20
F3S-B602P 41 F3S-B305P 26 F3S-B207P 20
F3S-B662P 45 F3S-B335P 28 F3S-B227P 21
Series connection types
The following chart shows the response time of combinations of a master unit and a slave unit connected in series. For example,
the response time of the combination of F3S-BM122P30 and F3S-BS302 is 30 ms.
Response time [ms] Response time [ms]
Slave unit F3S- BS122 BS182 BS242 BS302 Slave unit F3S- BS047 BS067 BS087 BS107
Master unit Master unit
F3S-BM122P## 20 23 27 30 F3S-BM047P## 20 20 20 20
F3S-BM182P## 23 27 30 34 F3S-BM067P## 20 20 20 20
F3S-BM242P## 27 30 34 37 F3S-BM087P## 20 20 20 20
F3S-BM302P## 30 34 37 41 F3S-BM107P## 20 20 20 20
F3S-BM362P## 34 37 41 45 F3S-BM127P## 20 20 20 21
F3S-BM422P## 37 41 45 49 F3S-BM147P## 20 20 21 23
F3S-BM482P## 41 45 49 54 F3S-BM167P## 20 21 23 24
F3S-BM542P## 45 49 54 57 F3S-BM187P## 21 23 24 25
F3S-BM602P## 49 54 57 61 F3S-BM207P## 23 24 25 26
F3S-BM662P## 54 57 61 65 F3S-BM227P## 24 25 26 27
Response time [ms]
Slave unit F3S- BS065 BS095 BS125 BS155
Master unit
F3S-BM065P## 20 20 20 21
F3S-BM095P## 20 20 21 22
F3S-BM125P## 20 21 22 24
F3S-BM155P## 21 22 24 26
F3S-BM185P## 22 24 26 28
F3S-BM215P## 24 26 28 30
F3S-BM245P## 26 28 30 32
F3S-BM275P## 28 30 32 34
F3S-BM305P## 30 32 34 35
F3S-BM335P## 32 34 35 37
G-36 Safety Sensors / Components
F502-EN2-04.book Seite 37 Dienstag, 26. Juli 2005 5:48 17
Characteristic data
Operating Range
F3S-B122P
Parapendicular to Center Line of Lenses Parallel to Center Line of Lenses
300
300
200 200
100 100
Y
Y
0
0
X
X
-100 -100
-200 -200
-300
-300
0 2 4 6 8 0 2 4 6 8
Distance X (m) Distance X (m)
F3S-B662P
Parapendicular to Center Line of Lenses Parallel to Center Line of Lenses
300 300
200 200
100 100
Y
Y
0 0
X
X
-100
-100
-200
-200
-300 -300
0 2 4 6 8 0 2 4 6 8
Distance X (m) Distance X (m)
F3S-B G-37
Distance Y (mm) Distance Y (mm)
Distance Y (mm)
Distance Y (mm)
F3S-B
F502-EN2-04.book Seite 38 Dienstag, 26. Juli 2005 5:48 17
I/O Circuit Diagram
IR-light Interlock Ext. test/blanking
indicator indicator indicator
Brown
2 +24 V
Green
3
External test
input
Grey
5
White
Main emitter
1
circuit
Pink Relay monitoring
input
6
Yellow
Interlock selection
4
input
Blue
7 0 V
ON-state OFF-stateInstability
indicator indicator indicator
Brown
2
Green
3
Pink
6
Control output 1
Load
Main receiver
circuit
White
Grey
1
5
Control output 2
Load
Yellow
4
Instability
Load
output
Blue
7
G-38 Safety Sensors / Components
RS-485(A)
RS-485(B)
F502-EN2-04.book Seite 39 Dienstag, 26. Juli 2005 5:48 17
Dimensions
Safety Light Curtain
F3S-B
Type A B
Protective Full length
height
M12 connector
F3S-B122, -B065, -B047 300 343
F3S-B182, -B095, -B067 450 493
F3S-B242, -B125, -B087 600 643
F3S-B302, -B155, -B107 750 793
F3S-B362, -B185, -B127 900 943
Master unit
F3S-B422, -B215, -B147 1050 1093
F3S-B482, -B245, -B167 1200 1243
F3S-B542, -B275, -B187 1350 1393
F3S-B602, -B305, -B207 1500 1543
F3S-B662, -B335, -B227 1650 1693
Note:All units are in Millimeters unless otherwise indicated.
40.3
M12 connector
Accessoires
Mounting Bracket (Top and Bottom) Mounting Plate
Only supplied with types which have a protective height of 1050 mm or longer (Including inter-
mediate brackets). Only needed for rear mounting
5.5
R2.75
12
16
22
20
42.74
7
20˚
36.5
R1.75
5
20
Ø 25.5
35˚ 3
6.25
3.5
4
22.5
28.74
46
30
R2.75 12
5.5
2
36
R4.5
F3S-B G-39
9.5
3
B 3
34 A (Protective height)
10.5
30
F3S-B
F502-EN2-04.book Seite 40 Dienstag, 26. Juli 2005 5:48 17
Intermediate Mounting Bracket
Only needed for types which have a protective height of 1050 mm or longer
Mounting screw for sensor (M6x8)
Flat intermediate bracket
Rubber
U-shaped intermediate bracket
Fixing screw for bracket (M4x10)
L-shaped intermediate bracket
Options (Order Separately)
Extension Cable
(Set of 2: Emitter > gray, Receiver > black)
F39-JB1A (L = 3 m)
42 L
F39-JB2A (L = 7 m)
F39-JB3A (L = 10 m)
Ø 15
M12 R ound vinyl-insulated cord
5.7 m m dia. (32/0.1 m m dia.) 8 cores
Unit: m m
Series Connection Cable
(Set of 2: Emitter > gray, Receiver > black)
F39-JB1B
300
48.5
Ø 15
M12
Unit: mm
Optional Function Kit
F39-EU1E
Note: The F3S-B is not in normal operation during connection with the F39-E1.
This set includes the following items:
The control outputs are held in their OFF-state. For detailed information
· F39-U1E OptionalFunction Software
please refer to “Details of F39-EU1E” in this data sheet.
· F39-E1 Interface Unit
!WARNING
· F39-JB1C Interface Cable
After setting the blanking function, check that the F3S-B detects a test
The F39-U1E Optional Function Software is the WINDOWS®
rod at any position in the F3S-B detection zone through which a per-
-based software for use with the F39-E1 Interface Unit to pro-
son reaches the hazardous part of the machine. If any positions are
found by check above, install protective structures to there to prevent
gram the F3S-B Safety Light Curtain, and provided with one
intrusion which F3S-B can not detect. Failure to do so may result in
3.5 inch floppy disk. This software has the following features:
serious injury.
· Set the following functions to the F3S-B
Perform the installation check and the periodical inspection described
in the F3S-B manual.
- Start interlock function
Disconnect the outputs of the F3S-B from the load when program-
- Relay monitoring function
ming it using the F39-U1E software and with F39-E1 interface unit.
- Blanking function
Failure to do so may result in serious injury.
· Display each axis and each input line condition of the F3S-B
Do not connect the F39-E1 to a power supply with a voltage higher than
· Change the ON delay time
24 VDC +20 %. Do not connect the F39-E1 to an AC power supply.
G-40 Safety Sensors / Components
F502-EN2-04.book Seite 41 Dienstag, 26. Juli 2005 5:48 17
Installation
Wiring
Disconnect all sources of power before wiring the F3S-B to a · Connect the receiver extension cable (F39-JBxA-D option-
machine. al, black color outer jacket) to the receiver. (The receiver
· Connect the emitter extension cable (F39-JBxA-L optional, unit uses black color plastic caps.)
gray color outer jacket) to the emitter. (The emitter uses · Connect the 0 V line of the power supply directly to protec-
gray color plastic caps.) tive earth (PE).
Note: Note:Be sure to wire correctly. Failure to do so may damage the F3S-B.
Signal Name
Wire Color
Front View Pin No.
of Extension Cable
Receiver Emitter
1 Control output 2 Relay monitoring input White
2 24 VDC 24 VDC Brown
3 Control output 1 External test input Green
7
6
4 Instability output Interlock selection input Yellow
1
8 5
5 RS-485 (A) RS-485 (A) Grey
2
4
3
6 RS-485 (B) RS-485 (B) Pink
7 0 V0 VBlue
8 N.C. / reserved*1 N.C. / reserved Red
*1. N.C. / reserved: do not connect
Emitter Receiver
E1: 24 VDC Power supply
S1: External test switch
K1, K2: Relay
K3: Relay to indicate unstable condition
RS-485(A) (Grey 5)
RS-485(B) (Pink 6)
S1
K1 K2
E1
K3
F3S-B G-41
Relay monitoring (White 1)
Ext. test (Green 3)
24 VDC (Brown 2)
0 V (Blue 7)
Interlock selection (Yellow 4)
Instability (Yellow 4)
24 VDC (Brown 2)
0 V (Blue 7)
Output 1 (Green 3)
Output 2 (White 1)
F3S-B
F502-EN2-04.book Seite 42 Dienstag, 26. Juli 2005 5:48 17
When using START/RESTART FUNCTION When using optional RELAY MONITORING FUNCTION
Emitter Receiver Emitter
RS-485(A) (Grey 5)
RS-485(B) (Pink 6)
k1
S2
k2
S1
E1
E1
K3
k1, k2: Auxiliary contact to moni
S2: Restart interlock reset switch
tor the condition of the final relay
Details of F39-EU1E Optional Function Kit
1. Installation
1.1 Preparation
· F39-JB1C Interface cable 5 m cable length, M8 connector
!WARNING
(4 pins)
Perform the installation check and the periodical inspection
30.5
5000
described in the F3S-B manual.
Do not disassemble, repair or modify the F39-E1.
Ø 15
Do not use the F39-E1 in flammable or explosive environ-
Round vinyl-insulated cord
ments.
5 mm dia. (32/0.1 mm dia.) 4 cores
To use the F39-U1E software, the following items are neces-
Unit : mm
sary.
· RS-232C cable (not included)
· Personal Computer (not included)
- Windows® 95, Windows® 98, or Windows NT®
- 133MHz Pentium® processor or better
1.2 Component Names and Functions of the F39-E1 Interface Unit
- 32MB RAM or higher for Windows® 95 and Windows® 98
SEND to RS-485 indicator (Red)
- 64MB RAM or higher for Windows NT®
SEND to RS-232C indicator (Yellow)
- A 115kBd RS-232 serial interface port or better
9pin D-Sub Connector
M8 Connector (RS-485) (RS-232C)
· F39-E1 Interface Unit
114
35
Communication indicator (Green)
SEND to RS-485 Indicator (Red)
8
60
Unit : mm
Lit when the F39-E1 sends data to the F3S-B via RS-485.
SEND to RS-232C Indicator (Yellow)
Lit when the F39-E1 sends data to the PC via RS-232C.
COMMUNICATION Indicator (Green)
Flashing during communication between the F3S-B and the
F39-E1.
G-42 Safety Sensors / Components
24 VDC (Brown 2)
0 V (Blue 7)
Interlock selection (Yellow 4)
Instability (Yellow 4)
24 VDC (Brown 2)
0 V (Blue 7)
Relay monitoring (White 1)
Ext. test (Green 3)
24 VDC (Brown 2)
0 V (Blue 7)
F502-EN2-04.book Seite 43 Dienstag, 26. Juli 2005 5:48 17
1.3 Hardware Connection Start/Restart interlock is a function which is selected by wiring.
Refer to the instruction manual of the F3S-B for more detailed
!WARNING
information.
Disconnect the outputs of the F3S-B from the load when program-
ming it using the F39-U1E software and with F39-E1 interface unit.
2.2 Relay Monitoring
Failure to do so may result in serious injury.
Do not connect the F39-E1 to a power supply with a voltage higher than
MPCEs (Machine Primary Control Elements) are usually re-
24 VDC +20 %.
lays or contactors used to control hazardous movement di-
Do not connect the F39-E1 to an AC power supply.
rectly. The state of the MPCEs can be checked with the Relay
monitoring function.
1.3.1 Wiring Diagram
A voltage of 17 VDC to Vs (Supplied voltage to F3S-B) has to
F3S- B
be applied to the Relay monitoring input through the NC con-
Emitter
Receiver
F39-U1E
tacts of the MPCEs when the F3S-B control outputs are in the
OFF-state (see the F3S-B manual for wiring information). To
PC
ensure this logic relation, the MPCEs must be safety ap-
proved types, with forcibly guided contacts.
Allowed Relay Delay Time
RS-232C
No.1 axis
The allowed relay delay time can be set between 20 and 300
ms. This delay time has to be set at least 20 milliseconds
RS-485(A) (Grey 5)
Note 1 shorter than the Outputs ON delay time.
RS-485(B) (Pink 6)
Note 1
2.3 Outputs ON Delay
F39-E1
You can set the ON delay time of control outputs between 80
and 400 ms. This corresponds to the time which the control
F39- JB1C
outputs go to ON-state after the detection zone is not inter-
+24 V (Brown 1)
rupted.
0V (Blue 3)
Note: 1 .When the Relay monitoring function is also used, the ON delay time
RS- 485(A) (Black 4)
RS- 485(B) (White 2)
must meet the formula below.
2 . ON delay time Allowed relay delay time + 20 ms After the Relay mon-
Note 1: See the instruction manual of F3S-B for wiring
itoring function is set, if the ON delay time does not meet the above
formula, the ON delay time will be changed automatically into ”Allowed
1.3.2 Wiring Procedure
relay delay time” + 20 ms.
2.4 Blanking
1. Connect the F3S-B (see the instruction manual of the F3S-
With the Blanking function, one or more axes can be disabled.
B for wiring.)
This function is useful in an application where a part of the
2. Connect the Interface cable (F39-JB1C) to the Interface
F3S-B detection zone is always interrupted. The Manual-set-
unit (F39-E1).
ting and the Teaching-setting are available to select the
3. Connect the 4 wires of the Interface cable to each appropri-
blanked axes.
ate line of the F3S-B.
Note: 1 . In the case the blanked zone is not filled with structure completely and
4. Connect an RS-232C cable to the PC and the Interface
remains some opening, the opening must be filled with the protective
structure.
unit.
2 .All axes can not be disabled. At least one axis needs to be active.
1.4 Software-Installation
Copy the file „F39-U1E_ver#.#.exe“ and F39-U1E_ver#.#dat
from the enclosed 3.5-inch floppy disk onto the hard disk of
the PC.
2. Function Description
2.1 Start Interlock
When the Start interlock function is used, the F3S-B does not
go to the ON-state automatically after power ON. Interrupting
one or more axes resets the start interlock condition of the
F3S-B then starts normal operation. The duration of the inter-
ruption must be equal or shorter as defined in the „Max. inter-
ruption time (sec)“.
Max. Interruption Time
The max interruption time can be set between 0.3 and 2 s.
Note: In the case both the Start interlock and the Start/restart interlock are se-
lected, only the Start/restart interlock will be activate.
F3S-B G-43
0V (Bluie 7)
24 VDC (Braun 2)
24 VDC (Braun 2)
0V (Bluie 7)
Open Output 1 (Green 3)
Open Output 2 (White 1)
F3S-B
F502-EN2-04.book Seite 44 Dienstag, 26. Juli 2005 5:48 17
3. Ratings and Performance
Type F39-E1 Interface unit
Supply voltage 24 VDC ± 20% (including 5 Vp-p ripple)
Current Consumption 120 mA max.
Interface RS-232C interface, RS-485 interface
Indicator See 1-2
Connection method RS-485: 4pins, M 8 connector
RS-232C: D-SUB connector, 9 pins
Protection circuit RS 485 protection against wrong wiring
Ambient Temperature During operation: –10 to 55° C (with no freezing)
During storage: –25 to 70° C
Ambient Humidity During operation : 35 to 85% RH (with no condensation)
Ambient Humidity During storage: 35 to 95% RH
Insulation Resistance 20 MΩ min. (at 500 VDC)
Dielectric strength voltage 500 VAC 50/60 Hz for 1 min.
Degree of Protection IEC60529 IP20
2
Shock resistance Normal operation: 150 m/s [15 G], ±X, ±Y and ±Z directions: 3 times
Vibration resistance Normal operation: 10 to 55 Hz, double-amplitude: 0.3mm, X, Y and Z directions: 10 sweeps
2
Cable length RS-485 cable: 5 m (4 pin 0.25 mm )
RS-232C cable: Standard
Materials Case: Aluminum
Size 122 x 60 x 35 mm
Conformity EMC Directive
G-44 Safety Sensors / Components
F502-EN2-04.book Seite 45 Dienstag, 26. Juli 2005 5:48 17
Precautions
!WARNING
1. Do not use the F3S-B on machines that can not be stopped by electrical control in case of an emergency.
2. Do not use the F3S-B in flammable or explosive environments
3. Always maintain the safety distance between F3S-B and a hazardous part of the machine. Serious injury may result if the ma-
chine does not stop before someone reaches the hazardous part.
4. Install protective structures around a machine so that you must pass through the detection zone to reach a hazardous part of
the machine.
5. Install F3S-B so that some parts of the operator’s body remain in the detection zone at all times when the operator works in the
hazardous area.
6. Failure to do so may result in serious injury.
Correct installation Incorrect installation
A hazardous part of a machine can be A hazardous part of the machine can be
reached only by passing through the sen- reached without passing through the sen-
sor detection zone. sor detected zone.
Some part of the operator’s body remains A worker is between the sensor detection
in the detection zone while they are work- zone and a hazardous part of a machine.
ing.
!WARNING
1. Be sure to install the F3S-B to minimize the effects of reflections from reflective surfaces. Failures to do so will create an inability
to detect and may result in serious injury
2. Install the F3S-B with a minimum distance D as shown below form the reflective surface (highly reflective surfaces) like metal
walls, floors, ceilings, and work pieces.
Reflecting ceiling
Reflecting surface
D
Emitter Receiver
D
Detection zone
5˚
5˚
L
Emitter Receiver
D
L
Reflecting floor
Distance between emitter and receiver (detection distance L) Minimum installation distance D
0.3 to 3 m 0.26 m
3 to 5 m L x tan 5° = L x 0.088 (m)
F3S-B G-45
F3S-B
F502-EN2-04.book Seite 46 Dienstag, 26. Juli 2005 5:48 17
!WARNING
When using multiple sets of the F3S-B, install them so that mutual interference is not incurred.
(Incorrect) (Incorrect)
RS-485
RS-485
(Incorrect)
Emitter 1
Receiver 1
RS-485
Emitter 2
Receiver 2
Alternate emitters and receivers
Correct installations are shown below to prevent mutual interference.
(Correct)
(Correct)
RS-485
RS-485 RS-485
(Correct)
Emitter 1
Receiver 1
Emitter 2
Receiver 2
RS-485
(Correct)
RS-485 RS-485
G-46 Safety Sensors / Components
Emitter 1
Emitter 1
Receiver 1
Receiver 1
Receiver 1
Emitter 1
Emitter 2
Emitter 2 Emitter 2
Receiver 2
Receiver 2 Receiver 2
Emitter 2 Emitter 1
Receiver 2 Emitter 1
Receiver 2 Receiver 1
Emitter 2 Receiver 1
F502-EN2-04.book Seite 47 Dienstag, 26. Juli 2005 5:48 17
!WARNING
1. The F3S-B is a TYPE 2 Electro-sensitive protective equip- (4.) The power supply automatically resets overcurrent
ment, intended to be used as or with the safety related part protection characteristics (voltage drop).
of control system to category 2, 1 or B as defined in the Eu- (5.) The power supply maintains an output holding time of
ropean standard EN954-1. at least 20 ms.
Do not use the F3S-B in category 3 or 4 systems. (6.) FG (frame ground terminal) must be connected to PE
2. A qualified person, as determind by local regulations, must (protective earth) when using a commercially available
confirm that installation, inspection and maintenance are switching regulator.
implemented correctly. (7.) The power supply must have output characterisitics re-
3. Do not short the output lines to the +24 V line. Doing so will quired for the power source for Class 2 Circuit or Lim-
cause the output to be always ON, creating a hazardous sit- ited Voltage / Current Circuit as defined in UL508.
uation. (8.) The power supply must conform to regulatory require-
4. Do not connect the F3S-B to a power supply with voltage ments and standards, regarding EMC and electrical
higher than 24 VDC + 20%. Do not connect the F3S-B to an equipment safety, of the country where the F3S-B is in-
AC power supply. stalled and where machinery will be operated, for ex-
5. Be sure to conduct inspections regularly. ample: The EMC Directive (industrial environment)
6. The F3S-B cannot be used in applications where hazard- and the Low Voltage Directive in EU.
ous projectiles may exit the protected zone. 9. Do not use the F3S-B in a direct retroreflective configura-
7. Do not disassemble, repair or modify the F3S-B. tion. Otherwise detection may fail.
8. DC power supply units must satisfy all of the conditions be-
low so that the F3S-B can comply with the applicable stan-
dards IEC 61496-1 and UL 508.
(1.) The power supply voltage must be within rating
(24 VDC ± 20%).
(2.) The power supply is connected only to the F3S-B and
to the electro-sensitive protective function of the F3S-
B, such as a safety controller and muting sensors, and
it has enough rated current for all the devices.
(3.) The power supply uses double or reinforced insulation
between the primary and secondary circuits.
F3S-B G-47
F3S-B
F502-EN2-04.book Seite 48 Dienstag, 26. Juli 2005 5:48 17
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. E503-E2-01-X In the interest of product improvement, specifications are subject to change without notice.
G-48 Safety Sensors / Components
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods