NOTIFIER GAMEWELL FCPS-24S6
Datasheet
Notifier-FCPS-24S6-Power Supply-datasheet1-1397823530.pdf
460 KiB
Extracted Text
dn-6927:a FCPS-24S6(C/E) & FCPS- 24S8(C/E) 6- & 8-Amp 24-Volt Remote Power Supplies Power Supplies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC syn- chronization) or auxiliary power to support 24 volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable, all resettable or two non- resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C & FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E 6927pho1.jpg Features • Includes integral battery charger capable of charging up to • UL-Listed NAC synchronization using System Sensor, 18 AH batteries. Cabinet capable of housing 7.0 AH batter- 2 Wheelock, or Gentex “Commander ” appliances. ies. • Operates as a “sync-follower” or as a “sync-generator” • Battery charger may be disabled via DIP switch for applica- (default). See note on page 2. tions requiring larger batteries. • Contains two fully-isolated input/control circuits - triggered • Fixed, clamp-type terminal blocks accommodate up to 12 2 from FACP NAC (NAC expander mode) or jumped perma- AWG (3.1mm ) wire. nently “ON” (stand-alone mode). • Four Class B (Style Y) or four Class A (Style Z, with Specifications ZNAC-4 module) NACs. Primary (AC) Power: • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- • FCPS-24S6C/-24S8C: 120 VAC, 60 Hz, 3.2A maximum. put, with 3 amps maximum/circuit, in NAC expander mode • FCPS-24S6E/-24S8E: 240 VAC, 50 Hz, 1.6A maximum. (UL 864). 2 • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous • Wire Size: minimum #14 AWG (2.0mm ) with 600 V insula- tion. output in stand-alone mode (UL 1481). • Compatible with coded inputs; signals passed through. Control Input Circuit: • Optional power-supervision relay (EOLR-1). • Trigger Input Voltage: 9 to 32 VDC. • In stand-alone mode, output power circuits may be config- • Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 ured as: resettable, (reset line from FACP required), - 16 V). non-resettable, or a mix of two and two. Trouble Contact Rating: 5 A at 24 VDC. • Fully regulated and filtered power output - optimal for pow- Auxiliary Power Output: Specific application power 500 mA ering four-wire smoke detectors, annunciators, and other maximum. system peripherals requiring regulated/filtered power. Output Circuits: • Power-limiting technology meets UL power-limiting require- ments. • +24 VDC filtered, regulated. • Form-C normally-closed trouble relay. • 3.0 A maximum for any one circuit. • Fully supervised power supply, battery, and NACs. • Total continuous current for all outputs (stand-alone mode): • Selectable earth fault detection. – FCPS-24S6: 4.0 A maximum. • AC trouble report selectable for immediate 2-hour delay. – FCPS-24S8: 6.0 A maximum. • Works with virtually any UL 864 fire alarm control which uti- • Total short-term current for all outputs (NAC expander mode): lizes an industry-standard reverse-polarity notification cir- – FCPS-24S6: 6.0 A maximum. cuit (including unfiltered and unregulated bell power). – FCPS-24S8: 8.0 A maximum. • Requires input trigger voltage of 9 - 32 VDC. Secondary Power (Battery) Charging Circuit: • Self-contained in compact, locking cabinet - 15”H x 14.5”W • Supports lead-acid batteries only. x 2.75”D (cm: 38.1H x 36.83W x 6.985D). • Float-charge voltage: 27.6 VDC. dn-6927:a • 04/30/09 — Page 1 of 2 • Maximum current charge: 1.5 A. Standards and Codes • Maximum battery capacity: 18 AH. The FCPS-24S6 and FCPS-24S8 comply with the following standards: Applications • NFPA 72 National Fire Alarm Code. Example 1: Expand notification appliance power an additional • UL 864 Standard for Control Units for Fire Alarm Systems 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four (NAC expander mode). Class B (Style Y) outputs or four Class A (Style Z) outputs • UL 1481 Power Supplies for Fire Alarm Systems. (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation Agency Listings and Approvals occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications Example 2: Use the FCPS to expand auxiliary regulated 24- may not be listed by certain approval agencies, or listing may volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A be in process. Consult factory for latest listing status. (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by con- • UL Listed: S635, S674 necting the resettable output from the FACP to one or both of • ULC Listed: S635 (FCPS-24S6C & FCPS-24S8C) the FCPS inputs. • CSFM Approved: 7315-0028:225 Example 3: Use addressable control modules to activate the • MEA: 299-02-E FCPS instead of activating it through the FACP notification • FM Approved appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. Ordering Information For example, an addressable control module is used to acti- FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. vate the FCPS, and an addressable monitor module is used to Includes main printed circuit board, transformers, enclosure sense FCPS trouble conditions. Local auxiliary power output (15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and from the FCPS provides power to the addressable control installation instructions. module. FCPS-24S6C: Same as above, ULC-listed. *NOTE: Addressable FACPs are capable of locating control and FCPS-24S6R: Same as FCPS-24S6 with red enclosure. monitor modules at distances of up to 12,500 feet (3,810 meters). FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Sync Follower/Generator Note Includes main printed circuit board, transformers, enclosure (15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and In some installations, it is necessary to synchronize the flash installation instructions. timing of all strobes in the system for ADA compliance. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When Includes main printed circuit board, transformers, enclosure (15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and installed at the end of a NAC wire run, the FCPS-24S6/-24S8 installation instructions. can track (i.e. “follow”) the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall FCPS-24S8C Same as above, ULC-listed. system flash timing of the additional strobes attaches to the FCPS-24S8R: Same as FCPS-24S8 with red enclosure. FCPS. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. When the FCPS-24S6/-24S8 is configured (via DIP switch set- Includes main printed circuit board, transformers, enclosure tings) as a “sync follower,” the FCPS’s NAC outputs track the (15”H x 14.5”W x 2.75”D [cm: 38.1H x 36.83W x 6.985D]), and strobe synchronization pulses present at the FCPS’s sync installation instructions. input terminal. The pulses originate from an upstream FACP or other power supply. ZNAC-4: Class A (Style Y) NAC option module. When the FCPS-24S6/-24S8 are configured (via DIP switch EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire settings) as a “sync generator,” the FCPS’s sync input termi- smoke detector power. nals are not used. Rather, the FCPS is the originator of the BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT strobe synchronization pulses on the FCPS’s NAC outputs. In Series data sheet DN-6933). “sync generator” mode, the sync type (System Sensor, Whee- PS-1270: Battery, 12-volt, 7.0 AH (two required, see PS lock, or Gentex) is selectable via DIP switch settings. Series data sheet DN-1109) System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — dn-6927:a • 04/30/09
Frequently asked questions
What makes Elite.Parts unique?
What kind of warranty will the FCPS-24S6 have?
Which carriers does Elite.Parts work with?
Will Elite.Parts sell to me even though I live outside the USA?
I have a preferred payment method. Will Elite.Parts accept it?
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods