NIOBRARA R&D SC902

Description
Niobrara R&D SC902 Cable Symax Programming; 6’ programming cable with TR92 transformer
Part Number
SC902
Price
Request Quote
Manufacturer
NIOBRARA R&D
Lead Time
Request Quote
Category
PRODUCTS - S
Datasheet
Extracted Text
SC902 SY/MAX Programming Cable Description The Niobrara SC902 Smart Cable is a SY/MAX® compatible RS-422 cable with a miniature RS-232/RS-422 converter built into the 9-pin RS-232 end. It is intended to be used to connect the 9-pin RS-232 COM: port of a personal computer directly to any SY/MAX compatible RS-422 port such as the COMM port of a SY/MAX programmable controller, a NIM, a D-LOG, or the RS-422/RS-485 port of any NR&D modules. When connected to a PLC COMM port or a powered RS-422 port of NR&D modules the SC902 is powered by the 5 volts normally used to power the hand-held programmer. When connected to a NIM, the D-LOG, or the non-powered RS-422 port of NR&D modules, or when running long distances (over 30 feet), the SC902 can be powered by the included AC adapter. Since the SC902 is not powered by the signal lines of the personal comput- er, it will work when other solutions fail, such as when the RS-232 signal power is too low, or the personal computer software does not turn on the DTR or RTS pin. When connected to a NIM the SC902 provides the loop-back required for the handshaking lines. No additional cabling or jumper is needed. “SY/MAX program- The RS-232 end is a female 9-pin connector with screws. The RS-422 end is a male 9-pin connector with ming cable with slide locks. The SC902 is normally 6 feet long but other lengths (up to 2,000 feet) are available. See price RS-232 <-> RS-422 list for ordering information. The SC902 can also be extended with a NR&D DE1 cable. converter built-in” The SC902 is a versatile RS-232/RS-422 adapter which can be modified for special applications. Call the factory for more information. Installation 1: Connect the male (silver backshell) end of the SC902 to an RS-422 port on the SY/MAX device. “Custom lengths are available” 2: Connect the female (black backshell) end of the SC902 to COM1: or COM2: of the personal computer. If the computer is equipped with a 25-pin RS-232 port, use the NR&D SC902K Smart Cable instead of the SC902 or use an SD016 9- to 25-pin adapter with the SC902. 3: If the SY/MAX device does not provide power, connect the cord from the AC adapter to the 3.5mm power jack on the back of the RS-232 backshell and plug the adapter body into a 120VAC 50/60 Hz outlet. 4: Refer to the instructions for the software package you are using. Cable Pinouts The male DE9 end of the cable is compatible with SquareD SY/MAX RS-422 ports. The pinout is as follows: Pinout Pin Function Pin Function 1 RXD-(data out of PLC) 6 CTS+ 2 RXD+ 7 GND or RTS- 3 TXD-(data into PLC) 8 CTS- 4 TXD+ 9 Cable Shield 5 V+ or RTS+ Pins 5 and 7 power the converter when driven to 5 volts by the hand-held programmer power output of a ©2007 Niobrara Research & Development All trademarks and registered trademarks are the property of their respective owners. Corporation Effective 18 July 2007 Specifications subject to change without notice Printed in USA Niobrara Research & Development Corporation www.niobrara.com programmable controller or echo the differential true signal to pins 6 and 8 for a NIM when the cable is powered by the AC adapter. The female DE9 end of the cable is an RS-232 DCE interface. The pinout is as follows: Pinout Pin Function Pin Function 1 DCD 6 DSR 2 TXD (to computer) 7 RTS 3 RXD (fom computer) 8 CTS 5 SG DSR and DCD are driven high by the SC902. The state of pins 4 (DTR) and 9 (RI) is ignored. Ordering Information The SC902 is available as: • SC902 6’ programming cable with TR92 transformer. • SC902-xx Custom length SC902 where xx is the length in feet. • SC902IC Include connector: RS-422/485 end is left off for pulling cable through bulkhead or conduit. • SC902PP Permanently powered: transformer leads are soldered to converter. • SC902ST Stripped and tinned end: RS-422/485 end is stripped and tinned no connector. • SC902K 6’ programming cable with an SD016 adapter for use with a 25-pin RS-232 port . • SC902NT 6’ programming cable, transformer not included . Related Equipment The SC902 has the following equipment available: • TR92 Replacement transformer, 120VAC (U.S.). • DE1 Differential extension cable. Trouble Shooting Niobrara Research & Development The baud rate of the COM: port of the personal computer is not the same as the baud rate of the SY/MAX port. Corporation P.O. Box 3418 The cable is not connected to the correct COM: port of the personal computer. Joplin, MO 64803 (800) 235-6723 The route being used in the software is not valid. (417) 624-8918 The AC adapter is required with the following devices: www.niobrara.com AIM4-D, -M, -2D, -2M ports 1 through 4; EPE5 all SY/MAX ports; MEB all SY/MAX ports; RM14K SY/MAX port; SPE4- 1D, -2D, -3D ports 1 through 4; Spectrum Controls Operator Interface; Square D Company: ALL SY/MAX ports except processor ports and processor ports more than 30 feet away; UCM4-D, -M all ports Specifications Warranty The SC902 carries a one year warranty from the date of shipment. See Niobrara’s Standard Terms and Conditions of Sale for additional warranty information. Dimensions Standard SC902 length is 6’. Power External Power: from TR92 110 VAC transformer (included) or 9 VDC, 200 mA power through the 3.5mm mono jack (tip +) or Port power: 5VDC, 100 mA from RS-422 port (pin 5 V+, pin 7 GND). Operating Conditions 0 to 60 degrees C operating temperature; -40 to 80 degrees C storage. Humidity up to 90% noncondensing; pressure altitude -200 to +10,000 feet MSL.
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the SC902 have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods