NEXCOM NEXKVM420F

Description
Nexcom NEXKVM420F Panel - KVM Control Panel w/out the following; Server Chassis, Backplane, Server Blade, Management Blade, Ethernet Feedthru Blade, Ethernet Switch Blade and CDROM/FDD Carrier.
Part Number
NEXKVM420F
Price
Request Quote
Manufacturer
NEXCOM
Lead Time
Request Quote
Category
BLADE SERVERS; SUB-SYSTEMS, CONTROLLERS & ENCLOSURES » BLADE SERVER KVM CONTROL PANEL
Specifications
Type
KVM Switch blade
Features
- Built-in KVM switch
- Cable consolidation by KVM switch and daisy chain technology minimizes maintenance downtime
- Features socket type CPU architecture
- Hot-swappable server blades, power modules, and cooling fan trays
- On-line access to KVM/CD-ROM/FDD for easy maintenance
- Redundant power modules ensure high reliability
- Superior performance, supports Intel® Xeon and LV Xeon processors
- Supports KVM switch daisy chain (up to 10 chassis)
- Supports on-board Gigabit LAN, for high throughput network infrastructures
- Supports PCI-X I/O expansion
- Supports remote KVM switch control. Server blade on/off control via Nexcare™ management software
- Ultra high dense design accommodates up to 10 blades within 4U height
Datasheet
Extracted Text
www.nexcom.com
The Digital Infrastructure
Blade Server
TM
NexBlade HS420 Series
User's Manual
TM
This manual serves to all NexBlade HS420
series models: HS420 / HS420A
2003-05 Edition
Blade Server
Preface
Copyright
This publication, including all photographs, illustrations and software, is protected under
international copyright laws, with all rights reserved. Neither this manual, nor any of the material
contained herein, may be reproduced without written consent of the author.
Version 1.0
Disclaimer
The information in this document is subject to change without notice. The manufacturer makes no
representations or warranties with respect to the contents hereof and specifically disclaims any
implied warranties of merchantability or fitness for any particular purpose. The manufacturer
reserves the right to revise this publication and to make changes from time to time in the content
hereof without obligation of the manufacturer to notify any person of such revision or changes.
Trademark Recognition
NexBlade™ HS420 (A) is a trademark of NEXCOM International Co., LTD. All other product
names used in this manual are the properties of their respective owners and are acknowledged.
Federal Communications Commission (FCC)
This equipment has been tested and verified to comply with Class A limits when configured into a
compatible host computer, pursuant to Part 15 of the FCC Rules, CISPR 22, and EN55022. These
limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and the receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
i
Blade Server
To ensure EMC compliance with your local regional rules and regulations, the final configuration of
your end system product may require additional EMC compliance testing. For more information,
please contact your local NEXCOM Representative.
WARNINGS
Turning off the power switch does not turn off power to the HS420 series. Disconnect the HS420
series from its power source and from any telecommunications links, networks, or modems before
doing any of the procedures described in this guide. Failure to do this can result in personal injury
or equipment damage. Some circuitry in the server may continue to operate even though the
power switch on the front panel is off.
This guide is for qualified technical personnel with experience installing and configuring servers.
Read and adhere to all warnings, cautions, and notices in this guide and the documentation
supplied with the chassis, power supply, and accessory modules. If the instructions for the chassis
and power supply are inconsistent with these instructions or the instructions for accessory
modules, contact the supplier to find out how you can ensure that your computer meets safety and
regulatory requirements.
CAUTION
Electrostatic discharge (ESD) can damage server components. Do the described procedures only
at an ESD workstation. If no such station is available, you can provide some ESD protection by
wearing an antistatic wrist strap and attaching it to a metal part of the computer chassis.
HARD DISK DRIVE CHOOSE WARNING
TUV approved Hard Disk Drive is preferred for TUV compliance Hard Disk drive-Optional,
(NWGQ2), generic, four provided, Input Voltage rated 5V dc/1.0A, 12V dc/1.8A maximum,
minimum clearance from uninsulated live parts 4.0mm.
Important Notice
The blade server has an auto-switch power supply from 110V to 230V; however, the system may
shutdown because of inadequate power input.
ii
Blade Server
Safety and Regulatory Requirements
Intended uses: This product was evaluated for use in computer rack cabinets within computer
rooms and similar locations. Other uses require further evaluation.
Safety Compliance
♦ CE approved
♦ UL approved
Declaration of Conformity
This device complies with part 15 of the FCC rules. Operation is subject to the following
conditions:
♦ This device may not cause harmful interference
♦ This device must accept any interference received, including interference that may cause
undesired operation.
About this Manual
Chapter 1
Provides an overview of the system, a list of package
Introducing the NexBlade™
components, and a list of general specifications.
HS420 Series
Chapter 2
Helps you set up a server environment, HS420 series server,
Getting Started
and explains how to use the server components.
Chapter 3
Shows you how to turn on the HS420 series.
Turning on the NexBlade™
HS420 Series
Chapter 4
Shows you how to hot swapping the HS420 series components.
Hot-Swapping Components
Chapter 5
The description of how to use the BIOS setup program.
NexBlade™ HS420 Series
BIOS
iii
Blade Server
Safety Information
Safety Information
1. Please read these safety instructions carefully.
2. Please keep this User‘s Manual for later reference.
3. Please disconnect this equipment from AC outlet before cleaning. Don‘t use liquid or
sprayed detergent for cleaning. Use moisture sheet or clothe for cleaning.
4. For plug-in equipment, the socket-outlet shall be installed near the equipment and shall be
easily accessible.
5. Please keep this equipment away from humidity.
6. Lay this equipment on a reliable surface when install. A drop or fall could cause injury.
7. Do not leave this equipment in an unconditioned environment, or storage temperature
above 35°C; it may damage the equipment.
8. The openings on the enclosure are for air convection hence protects the equipment from
overheating. DO NOT COVER THE OPENINGS.
9. Make sure the voltage of the power source when connect the equipment to the power outlet.
10. Place the power cord such a way that people can not step on it. Do not place anything over
the power cord. The power cord must be rated for the product and for the voltage and
current marked on the product’s electrical ratings label. The voltage and current rating of the
cord should be greater than the voltage and current rating marked on the product.
11. All cautions and warnings on the equipment should be noted.
12. If the equipment is not use for long time, disconnect the equipment from mains to avoid
being damaged by transient over-voltage.
13. Never pour any liquid into ventilation openings; this could cause fire or electrical shock.
14. Never open the equipment. For safety reason, qualified service personnel should only open
the equipment.
15. If one of the following situations arises, get the equipment checked by qualified service
personnel:
a. The Power cord or plug is damaged.
b. Liquid has penetrated into the equipment.
c. The equipment has been exposed to moisture.
d. The equipment has not work well or you can not get it work according to user‘s manual.
e. The equipment has dropped and damaged.
f. If the equipment has obvious sign of breakage
iv
Blade Server
17. Do not place heavy loads on the equipment.
18. Ensure that all KVM and Server Blade board screws are securely fastened.
19. The unit uses a three-wire ground cable, which is equipped with a third pin to ground the unit
and prevent electric shock. Do not defeat the purpose of this pin. If your outlet does not
support this kind of plug, contact your electrician to replace your obsolete outlet.
20. Do not hot-swap a Server Blade board when transferring files with the CD-ROM or floppy
disk drive.
21. CAUTION: THE COMPUTER IS PROVIDED WITH A BATTERY-POWERED REAL-TIME
CLOCK CIRCUIT. THERE IS A DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY
REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVLENT TYPE RECOMMENDED
BY THE MANUFACTURE. DISCARD USED BATTERIES ACCORDING TO THE
MANUFACTURER’S INSTRUCTIONS.
22. THE COMPUTER IS PROVIDED WITH CD DRIVES COMPLY WITH APPROPRIATE
SAFETY STANDARDS INCLUDING IEC 60825.
v
Blade Server
Wichtige Information zur Sicherheit
Wichtige Information zur Sicherheit
Sicherheitshinweise
Sicherheitshinweise
1. Bitte lesen Sie sorgfältig diese Sicherheitshinweise.
2. Bitte bewahren Sie dieses Benutzerhandbuch zur späteren Einsicht auf.
3. Bitte trennen Sie dieses Gerät vor seiner Reinigung von der Netzsteckdose. Benutzen Sie zur
Reinigung kein flüssiges oder Spray-Reinigungsmittel. Benutzen Sie zur Reinigung ein
feuchtes Tuch oder einen feuchten Lappen.
4. Bei steckbaren Geräten soll sich die Steckdose in der Nähe des Gerätes befinden und leicht
zugänglich sein.
5. Bitte bewahren Sie dieses Gerät vor Feuchtigkeit.
6. Legen Sie dieses Gerät beim Einbau auf eine sichere Unterlage; Sturz oder Fall könnte es
beschädigen.
7. Lassen Sie dieses Gerät nicht in einer unklimatisierten Umgebung oder einer höheren
Lagertemperatur als 35°C; es könnte Schaden leiden.
8. Die Gehäuseöffnungen dienen der Luftkonvektion und schützen das Gerät vor Überhitzung.
BEDECKEN SIE DIE ÖFFNUNGEN NICHT!
9. Überprüfen Sie die Spannung der Stromquelle, bevor Sie das Gerät an die Steckdose
anschließen.
10. Verlegen Sie das Netzkabel so, dass man nicht darauf treten kann. Legen Sie nichts auf das
Netzkabel. Das Netzkabel muss für das Gerät sowie die auf seinem elektrischen Kennschild
angegebenen Strom- und Spannungswerte bemessen sein. Die Strom- und
Spannungsbemessung des Netzkabels sollte höher als die auf dem Gerät angegebenen
Strom- und Spannungswerte sein.
11. Alle Vorsichtshinweise und Warnungen auf dem Gerät sollten beachtet werden.
12. Falls das Gerät längere Zeit nicht benutzt wird, trennen Sie es vom Netz, um Beschädigung
durch kurzfristige Überspannungen zu vermeiden.
13. Vergießen Sie niemals irgendeine Flüssigkeit in die Belüftungsöffnungen, dies kann Brand
oder elektrischen Schlag verursachen.
14. Öffnen Sie das Gerät nie. Aus Sicherheitsgründen darf nur qualifiziertes Servicepersonal das
Gerät öffnen.
15. Lassen Sie das Gerät von qualifiziertem Servicepersonal prüfen, falls sich einer der folgenden
Vorfälle ergibt:
vi
Blade Server
a. Das Netzkabel oder der Stecker ist beschädigt.
b. Flüssigkeit ist in das Gerät eingedrungen.
c. Das Gerät ist Feuchtigkeit ausgesetzt worden.
d. Das Gerät arbeitet nicht richtig oder Sie können es nicht dem Benutzerhandbuch
entsprechend zum Arbeiten bringen.
e. Das Gerät ist gefallen und beschädigt.
f. Falls das Gerät offensichtliche Bruchstellen aufweist.
17. Stellen Sie keine schweren Lasten auf das Gerät.
18. Stellen Sie sicher, dass alle KVM- und Schlitzschrauben des Gehäuses einwandfrei befestigt
sind.
19. Die Einheit benutzt ein dreiadriges Erdungskabel, das mit einem dritten Anschlussstift zur
Erdung ausgestattet ist, um elektrischen Schlag zu vermeiden. Annullieren Sie den Zweck
dieses Anschlussstiftes nicht. Falls Ihre Steckdose diese Art Stecker nicht aufnimmt, ziehen
Sie Ihren Elektriker zu Rate, um die veraltete Steckdose zu ersetzen.
20. VORSICHT: DER COMPUTER IST MIT EINER BATTERIEBETRIEBENEN ECHTZEITUHR
AUSGESTATTET: BEI FALSCHEM BATTERIEERSATZ BESTEHT EXPLOSIONSGEFAHR.
NUR DURCH GLEICHEN ODER GLEICHARTIGEN VOM HERSTELLER EMPFOHLENEN
TYP ERSETZEN. GEBRAUCHTE BATTERIEN ENTSPRECHEND DEN ANWEISUNGEN
DES HERSTELLERS ENTSORGEN.
21. DER COMPUTER IST MIT CD-LAUFWERKEN IN ÜBEREINSTIMMUNG MIT DEN
ENTSPRECHENDEN SICHERHEITSNORMEN, IEC 60825 EINGESCHLOSSEN,
AUSGERÜSTET.
CLASS 1 LASER PRODUCT
KLASSE 1 LASER-PRODUKT
vii
Blade Server
Table of contents
Preface.................................................................................................................................................i
Copyright..........................................................................................................................................i
Disclaimer ........................................................................................................................................i
Trademark Recognition....................................................................................................................i
Federal Communications Commission (FCC) .................................................................................i
WARNINGS.....................................................................................................................................ii
CAUTION ........................................................................................................................................ii
HARD DISK DRIVE CHOOSE WARNING .....................................................................................ii
Important Notice..............................................................................................................................ii
Safety and Regulatory Requirements............................................................................................ iii
Safety Compliance......................................................................................................................... iii
Declaration of Conformity............................................................................................................... iii
About this Manual .......................................................................................................................... iii
Safety Information..........................................................................................................................iv
Wichtige Information zur Sicherheit ...............................................................................................vi
Sicherheitshinweise .......................................................................................................................vi
Table of contents.............................................................................................................................. viii
Table of figures ..................................................................................................................................xi
Chapter 1 Introducing the NexBlade™ HS420 Series.................................................................... 1
About the HS420 series ................................................................................................................. 1
Unpacking the NexBlade™ HS420 Series Server......................................................................... 2
NexBlade™ HS420 Series Models Components Comparison...................................................... 3
Components Color Identification.................................................................................................... 4
NexBlade™ HS420 Series Models General Features................................................................... 5
HS420 Series Product Specification..............................................................................................6
Server Blade Specification............................................................................................................. 7
Server Blade (HDB42720) for HS420 ........................................................................................ 7
Server Blade (HDB42722) for HS420A...................................................................................... 7
Environment Specification ............................................................................................................. 8
Front Panel Features ..................................................................................................................... 9
KVM Control Panel..................................................................................................................... 9
viii
Blade Server
Server Blade Features ..................................................................................................................11
Rear Panel Feature...................................................................................................................... 13
Power Supply Modules and Power Inlets................................................................................. 13
Basic Management Blade and Advanced Management Blade................................................ 15
Ethernet Feedthru Blade and Ethernet Switch Blade............................................................... 17
The Correspondent Network........................................................................................................ 19
Ethernet Feedthru Blade .......................................................................................................... 19
Ethernet Switch Blade .............................................................................................................. 20
Chapter 2 Getting Started ............................................................................................................. 21
Choosing a Suitable Environment................................................................................................ 21
Setting Up the Server Environment ............................................................................................. 22
Choosing a Rack ...................................................................................................................... 22
Server Room Layout................................................................................................................. 23
Managing Cables...................................................................................................................... 23
Securing the Server Room ....................................................................................................... 23
Attaching the Mounting Rail ......................................................................................................... 24
Assigning an ID............................................................................................................................ 25
To Use the HS420 series as a Stand Alone Server ................................................................. 26
To Daisy Chain Several HS420 series Chassis within a Rack................................................. 26
Daisy Chaining............................................................................................................................. 27
Basic Management Blade ........................................................................................................ 27
Advanced Management Blade ................................................................................................. 29
Connecting Peripheral Devices.................................................................................................... 30
Connecting a PS/2 Keyboard, Mouse and Display Monitor ..................................................... 30
Connecting LAN Port ................................................................................................................... 32
Stacking two Ethernet Switch Blades .......................................................................................... 32
Connecting Management Port on the Management Blade.......................................................... 32
Chapter 3 Turning on the NexBlade™ HS420 Series................................................................... 33
Turning on the Power Supplies.................................................................................................... 33
Software Installation..................................................................................................................... 34
Using USB Device.................................................................................................................... 34
Booting from LAN ..................................................................................................................... 34
Using NEXCOM® NEXIK™ ..................................................................................................... 35
Using the Server Blade Board Button and KVM Control Panel ................................................... 36
ix
Blade Server
Chapter 4 Hot-Swapping Components ......................................................................................... 41
Hot-Swapping Server Blade board .............................................................................................. 41
Hot-Swapping the KVM Control Panel......................................................................................... 42
Hot-Swapping Power Supply Modules......................................................................................... 43
Hot-Swapping Management Blade .............................................................................................. 44
Basic Management Blade ........................................................................................................ 44
Advanced Management Blade ................................................................................................. 45
Hot-Swapping Cooling Fan Trays ................................................................................................ 45
Hot-Swapping Ethernet Feedthru Blade and Ethernet Switch Blade .......................................... 46
Chapter 5 NexBlade™ HS420 Series BIOS ................................................................................. 47
About the BIOS ............................................................................................................................ 47
When to Run BIOS....................................................................................................................... 47
Getting Help ................................................................................................................................. 48
Main Menu ................................................................................................................................... 48
Status Page Setup Menu/Option Page Setup Menu ................................................................... 48
Control Keys................................................................................................................................. 48
Entering Setup ............................................................................................................................. 49
Standard CMOS Features ........................................................................................................... 51
Boot Device Sequence................................................................................................................. 54
Integrated Peripherals.................................................................................................................. 55
Power Management Setup .......................................................................................................... 56
Load Optimized Defaults Option .................................................................................................. 57
Set Supervisor Password............................................................................................................. 57
Set User Password ...................................................................................................................... 58
Save & Exit Setup ........................................................................................................................ 58
Exit Without Saving...................................................................................................................... 58
x
Blade Server
Table of figures
Figure 1 : HS420 ……………………………………………………………………… ......................…1
Figure 2 : HS420 Series Front View .............................................................................................3
Figure 3 : HS420 Series Back View ............................................................................................. 3
Figure 4 : KVM Control Panel ....................................................................................................... 9
Figure 5 : Server Blade Board Front Panels ...............................................................................11
Figure 6 : HS420 Series Rear Panel .......................................................................................... 13
Figure 7 : Basic Management Blade and Advanced Management Blade .................................. 15
Figure 8 : Ethernet Feedthru Blade and Ethernet Switch Blade ................................................17
Figure 9 : The correspondent network on Ethernet feedthru blade ............................................ 19
Figure 10 : The correspondent network on Ethernet switch blade ............................................. 20
Figure 11 : HS420 series chassis mounting holes location ........................................................ 24
Figure 12 : Side View of HS420 Series with Mounting Rail ........................................................24
Figure 13 : Chassis ID Define Dial .............................................................................................25
Figure 14 : Daisy Chain Ports ..................................................................................................... 27
Figure 15 : Daisy chaining HS420 Series Chassis by Basic Management Blade ...................... 28
Figure 16 : Daisy chaining HS420 Series Chassis by Advanced Management Blade .............. 29
Figure 17 : Connecting an external devices by Basic Management Blade ................................ 31
Figure 18 : Connecting an external devices by Advanced Management Blade ......................... 31
Figure 19 : Stacking two Ethernet Switch Blades .......................................................................32
Figure 20 : Turning on the HS420 series power supplies ..........................................................33
Figure 21 : NEXCOM NEXIK 410 ............................................................................................... 35
Figure 22 : Turning on the Server Blade and KVM Control Panel ..............................................36
Figure 23 : Server Blade Board Power LEDs .............................................................................36
Figure 24 : Selecting a Server Blade Board by System Right/Left Selection Buttons ............... 37
Figure 25 : Selecting a Server Blade Board by KVM/Access Button .........................................37
Figure 26 : Selecting a Different Chassis ...................................................................................38
Figure 27 : Server Blade Lock Button ......................................................................................... 38
Figure 28 : System Fault Alarm LED ..........................................................................................39
Figure 29 : System/HDD Status LEDs ........................................................................................ 39
Figure 30 : LAN Indicator LEDs .................................................................................................. 40
Figure 31 : Hot-Swapping a Server Blade board ........................................................................41
Figure 32 : Hot-Swapping KVM Control Panel (1) ......................................................................42
xi
Blade Server
Figure 33 : Hot-Swapping KVM Control Panel (2) ......................................................................42
Figure 34 : Hot–Swapping Power Supply Modules (1) ............................................................... 43
Figure 35 : Hot–Swapping Power Supply Module (2) ................................................................43
Figure 36 : Hot–Swapping Power Supply Modules (3) ............................................................... 43
Figure 37 : Hot-Swapping Basic Management Blade (1) ...........................................................44
Figure 38 : Hot–Swapping Basic Management Blade (2) ..........................................................44
Figure 39 : Hot–Swapping Basic Management Blade (3) ..........................................................44
Figure 40 : Hot–Swapping Advanced Management Blade .........................................................45
Figure 41 : Hot-Swapping Cooling Fan Trays ............................................................................45
Figure 42 : Hot-Swapping Ethernet Feedthru Blade .................................................................. 46
Figure 43 : Hot-Swapping Ethernet Switch Blade ......................................................................46
Figure 44 : Setup Utility Main Screen ......................................................................................... 49
Figure 45 : Standard CMOS Setup Screen ................................................................................ 51
Figure 46 : IDE Primary/Secondary Master/Slave Setup Screen ............................................... 52
Figure 47 : Integrated Peripherals Screen .................................................................................54
Figure 48 : Integrated Peripherals Screen .................................................................................55
Figure 49 : Power Management Screen ..................................................................................... 56
xii
Blade Server
Chapter 1 Introducing the NexBlade™ HS420 Series
About the HS420 Series
About the HS420 Series
NexBlade™ HS420 series is a 4U height, HA/HD (high availability/ high density), cost-effective
server platform designed to run mission-critical applications in ultra-dense computing
environments. The product achieves excellence in terms of its aggregated 20 Intel® Xeon™
computing power and 20Gb network throughput. In addition, NexBlade™ HS420 series enables
the application-specific blade server platform with the integrated PCI-X expansion feature for the
applications require specific add-in cards or controllers. The HS420 series rack-mount platform
includes a rear panel that provides daisy chain
connectors and network hubs, allowing you to
create larger network systems. Up to 100 server
blades can be installed inside the 42U-rack
cabinet. A single set of standard console devices
is shared by all the systems within the rack,
simplifying the system management and
reducing the need for redundant console
Figure 1 : The HS420
devices.
The server is built with integrated KVM
(Keyboard/Video/Mouse) switch, peripheral switch, and Gigabit Ethernet switch. NEXCOM’s
proprietary KVM and daisy chain technologies provide secure data management and minimize
inconvenient cable arrangements. When remote maintenance is necessary, the built-in KVM
switch enables users to control the KVM switch remotely via the NexCare software utility. The
peripheral switch allows the sharing of CD/ROM drive and FDD drive, while the Gigabit Ethernet
switch allows high speed interconnection among the server blades. Multiple chassis can be
stacked up together to share KVM device by linking the KVM daisy chain ports reserved on each
chassis. With the built-in remote management module, system administrator controls the HS420
series server securely anytime, anywhere.
The compact design of the HS420 series frees up more space and allows data centers to provide
more computing horsepower in the same square footage.
Please see the following page for the comparison of HS420 series models.
For complete specifications of the server and server blade boards, refer to HS420 Series Product
Specification on page 6.
1
Blade Server
Unpacking the NexBlade™ HS420 Series Server
Unpacking the NexBlade™ HS420 Series Server
The NexBlade™ HS420 series comes securely packaged in a sturdy cardboard shipping carton.
Upon receiving your computer, open the carton and carefully remove the contents. If anything is
missing or damaged, please contact your computer dealer immediately. The shipping carton
should contain the following items:
• HS420 chassis, KVM modules, power modules, filler for unpopulated slot and cooling fan trays
• Server Blade boards in a separate carton
• Accessory kit:
– Three power cords
– User’s Manual/Service Manual/Quick Reference
– One Utility CD-ROM
– One KVM dangle cable for connecting to PS/2 keyboard, mouse, and VGA monitor
– Two serial port interface cables
– Thermal conductive pad
• Optional Accessory:
– 68-pin Daisy Chain cable
– HS420 Mounting Rail
The KVM modules include the following components:
• KVM Switch blade – NEXKVM420F
• Management blade – NEXKVM420R
Do not throw the packaging materials away. You may need them later if you have to ship the
computer for repairs.
2
Blade Server
NexBlade™ HS420 Series Models Components Comparison
NexBlade™ HS420 Series Models Components Comparison
The figures below show the components of HS420 series:
Server Blade
KVM Control
Panel
Figure 2 : HS420 Series Front View
Cooling Fans
Basic Management
Power Supply
Blade
Power Supply Modules
Ethernet Ethernet
Switch Blade Feedthru Blade
Advanced Management Blade
Figure 3 : HS420 Series Back View
HS420 series includes HS420 and HS420A models. Table 1 shows the components used in both
models.
Model HS420 HS420A
HCK420 HCK420A
Chassis
Back Plane MBP410-EL MBP410
HDB42720 HDB42722
Server Blade
KVM Control Panel NEXKVM420F
NEXKVM420R
Basic Management Blade
Advanced Management Blade SMB410
CMB410-EL CMB410
Ethernet Feedthru Blade
Ethernet Switch Blade - GSB410
NEXIK410 NEXIK410
CDROM/FDD Carrier
Table 1 : HS420 Series Models Components Comparison
3
Blade Server
Components Color Identification
Components Color Identification
Some of the components are applicable to both HS420 and HS420A models; others are only used
in HS420 or HS420A. To prevent miss-handing or incorrect usage, each HS420 series component
has its own identity color. Green represents the common components used in both HS420 and
HS420A. Yellow color stands for the components only compatible to in HS420. Blue color is for
HS420A model only.
Components HS420 HS420A
Yellow Blue
Chassis
Back Plane Yellow Blue
Yellow Blue
Server Blade
KVM Control Panel Green
Green
Basic Management Blade
Advanced Management Blade Green
Yellow Blue
Ethernet Feedthru Blade
Ethernet Switch Blade - Blue
Green
CDROM/FDD carrier
Table 2 : Identify HS420 Series Models Components by color
Note: The identity color on the chassis is shown in upper and lower open edges of the server blade slots.
4
Blade Server
NexBlade™ HS420 Series Models General Features
NexBlade™ HS420 Series Models General Features
The NexBlade™ HS420 series has the following great features:
♦ Ultra high dense design accommodates up to 10 blades within 4U height
♦ Features socket type CPU architecture
♦ Superior performance, supports Intel® Xeon and LV Xeon processors
♦ Supports on-board Gigabit LAN, for high throughput network infrastructures
♦ Built-in KVM switch
♦ Supports KVM switch daisy chain (up to 10 chassis)
♦ Supports remote KVM switch control. Server blade on/off control via Nexcare™ management software
♦ Cable consolidation by KVM switch and daisy chain technology minimizes maintenance downtime
♦ Supports PCI-X I/O expansion
♦ Hot-swappable server blades, power modules, and cooling fan trays
♦ Redundant power modules ensure high reliability
♦ On-line access to KVM/CD-ROM/FDD for easy maintenance
For complete specification of the HS420 series chassis and server blade boards, please refer to
Appendix A in the Service Manual.
5
Blade Server
HS420 Series Product Specification
HS420 Series Product Specification
Construction 4U 19-inch Rackmount steel
Server Blade Slot Up to 10 front-accessible and hot-swappable blades. Please see
the following page for the server blade specification
Power Supply module Max. 2100 watt, 6+1 hot-swap redundant power supply on the rear,
with load balancing, rating from 100-230 Vac auto range
Cooling System Four hot-swappable cooling fans on the rear
KVM Switch Concentrate keyboard/VGA/Mouse from server blades to chassis
KVM port
Up to 10 chassis (total 100 blades) can be stacked together to
share one KVM device
Front accessible KVM control panel to select KVM among chassis
and blades
Chassis management Two management blades available:
♦ Basic management blade for basic management
♦ Advanced management blade for richer feature management
Please refer to page 15 for more detail
Networking Two networking blade slots available for the following options:
♦ Ethernet Feedthru Blade
♦ Ethernet Switch Blade (For HS420A model only)
Please refer to page 17 for more detail
Controls Power On/Off switch and three AC inlets on the rear panel.
6
Blade Server
Server Blade Specification
Server Blade Specification
Server Blade (HDB42720) for HS420
System Single Intel ® Xeon® processor up to 2.4 GHz
Up to 4GB DDR SDRAM, two 184-pin DIMM sockets
Memory
Expansion PCI-X add-on I/O pack
Dual Gigabit Ethernet (rear access)
I/O Output
One USB port (front access)
Hard Disk Drive On-board 2.5 inch ATA 100 IDE HDD or CompactFlash
Operating Systems Supported Windows 2000 Server/Advanced Server, Windows XP, RedHat
Linux 8.0, 9.0, FreeBSD 4.6
Regulation FCC CE class A, CB
Server Blade (HDB42722) for HS420A
System Processor Dual Intel® LV Xeon® 2.0 GHz processor or Single Intel® Xeon®
2.4 GHz processor
Memory Up to 4GB DDR SDRAM, two 184-pin DIMM sockets
Expansion PCI-X add-on I/O pack
I/O Output Dual Gigabit Ethernet (rear access)
One USB port (front access)
Hard Disk Drive On-board 2.5 inch ATA 100 IDE HDD or CompactFlash
Operating Systems Supported Windows 2000 Server/Advanced Server, Windows XP, RedHat
Linux 8.0, 9.0, FreeBSD 4.6
Regulation FCC CE class A, CB
7
Blade Server
Environment Specification
Environment Specification
Dimension (W x H x D) 426mm x 177mm x 670mm
16.78” x 6.97” x 26.40”
Weight Minimum: 28 kg (61 lb) exclusive server blade
Maximum: 50 kg (110 lb) when full configured
Note: Each server blade weight 2 kg
Operating Environment Temperature: 0 to 35 Degree Celsius
Relative humidity: 10% to 90% (Non-condensing)
Storage Environment Temperature: -20 to 80 Degree Celsius
Relative humidity: 10% to 90% (Non-condensing)
Heat Output Minimum: 1050 watts
Maximum: 2100 watts
Power Requirement 100 ~ 230 VAC input
AC inlet x 3
Power consumption: Minimum 1.3 KVA (3+1 redundancy)
Maximum 2.6 KVA (6+1 redundancy)
8
Blade Server
Front Panel Features
Front Panel Features
The HS420 Series front panel consists of one KVM Control Panel module and up to ten Server
Blades.
KVM Control Panel
Figure 4 : KVM Control Panel
9
Blade Server
Button/LED Function
System Fault LED When lit, this LED indicates power fault.
When this LED is blue, indicates the KVM Control Panel is
KVM LED
power on.
When this LED is green, indicates the chassis, which possess
the KVM access.
System Right/Left These buttons only function when the chassis ID is selected
KVM Select Buttons as the master. Use these buttons to assign KVM access to
selected blade. The left arrow selects blade to the left. The
right arrow selects blade to the right.
Chassis Up/Down These buttons only function when the chassis ID is selected
KVM Select Buttons as the master. Use these buttons to assign the KVM access to
selected chassis. The up arrow selects chassis above. The
down arrow selects chassis below.
Note: These buttons don’t operate when the chassis ID is set
to single chassis.
CDROM/FDD Lock Button Press the button to assign the exclusive access to the server
blade when CD-ROM, FDD to selected server blade when
NEXIK420 is available on your system. Please refer to page
37 for how to use NEXIK420.
Note: Before installing server blades into the chassis, ensure that you set the chassis ID properly. Refer to
Daisy Chaining on page 28.
10
Blade Server
Server Blade Features
Mounting Knots
KVM/Access
KVM/ACCESS
Button
Indicator LEDs
LAN 1
USB Port
Power Button
POWER
Blade Lock and
Handle
Figure 5 : Server Blade Board Front Panels
11
Blade Server
Button/LED Function
KVM/Access Button Press down over 5 seconds to obtain the KVM access.
Indicator LEDs PWR/KVM LED
– Blue LED indicates the server blade is power on.
– Green LED indicates the KVM is selected for operation.
Statue LED
– Orange LED indicates the Hard Disk is active.
– Red LED indicates a system fault.
LAN1/LAN2 LED
– Green LED indicates the connection status.
– When the LED is flashing, indicates the connection is active.
Support USB Version 1.1
USB Port
Power Button This button is to turn on and off the blade server.
12
Blade Server
Rear Panel Features
Rear Panel Features
This section describes features of the HS420 series rear panel. The rear panel consists 4 cooling
fans, 7 power supply modules, 3 power supply inlets, Basic/Advanced Management Blade, and
Ethernet Feedthru Blade/Ethernet Switch Blade.
Power Supply Modules and Power Inlets
Figure 6 : HS420 Series Rear Panel
13
Blade Server
Item Function
Cooling Fan Trays These trays hold the HS420 series hot-swappable cooling fan units. Each tray
includes one 10-cm ball bearing fan unit.
Power Supply Hot-swappable power supplies for the whole system. Each power supply
Modules module provides 350-watt electric power.
AC Inlet for Power These inlets supply power to the system. One inlet supports two power supply
Supplies modules.
Power Switch Press this main power switch enables you to turn on the HS420 series server.
To turn off, press the main power switch over 4 seconds.
14
Blade Server
Basic Management Blade and Advanced Management Blade
User can choose either Basic Management Blade or Advanced Management Blade depends on
the usage. Both contain KVM Daisy Chain Connectors. Basic Management Blade provides one
LAN port and one serial port while Advanced Management Blade endows one Serial console ports,
two LAN ports and two Serial ports for remote management function.
Figure 7 : Basic Management Blade and Advanced Management Blade
15
Blade Server
Item Function
Daisy Chain These connectors are exclusively used for chassis daisy chain purposes.
Connectors
Refer to Daisy Chaining on page 28 for more information.
Chassis ID Dial Use this dial to define the chassis ID of each HS420 series. The values on the
dial range from 0 to 15. With a 42U rack populated with HS420 series chassis,
the master chassis and must set its dial to 0. The remaining HS420 series
chassis can have independent 10 selections.
WARNING: ID duplication is prohibited and may cause internal damage to
your HS420 series server.
On/Off Switch Turns the management blade on and off. The management blade must be
turned on to enable the KVM Control Panel and chassis monitoring function.
ERR LED Light When lit indicates system fault. (Please call our certified service person to
check your system)
NexCare Management This RJ-45 port is for managerial functionalities through a LAN/serial interface.
Port Please refer to NEXCOM® Nexcare® User’s Manual for more detail.
Serial Port COM1: This serial port is connected direct from the server blade for serial
console, and only responds to the KVM switch selected server blade.
COM2: This port allows user to connect external devices by a null modem
cable.
Note: When you are using the Basic Management Blade for your HS420
series server. The only serial port on the Basic Management Blade is able
to connect with a one-to-two COM port connection cable. The black COM
port connector stands for COM1; the gray COM port connector identifies
COM2.
LAN Port These LAN switch ports on the advanced management blade support 10/100
Mbps Ethernet, which is supported direct from Blade server.
(Only on Advanced
Management Blade)
16
Blade Server
Ethernet Feedthru Blade and Ethernet Switch Blade
HS420 Series provides user with two types of network blades. Ethernet Feedthru blade provides
user with Gigabit LAN port that is connected directly to the blade server. Ethernet Switch blade
contains a build-in Gigabit LAN switch, which possesses 2 RJ-45 ports and 2 SFP (Small
Form-Factor Pluggable Port). Depending on requirement, user can combine using one Ethernet
Feedthru blade and one Ethernet Switch blade together to meet variety tasks. For more detail
features of Ethernet Feedthru blade and Ethernet Switch blade, please see figure and table below:
Figure 8 : Ethernet Feedthru Blade and Ethernet Switch Blade
17
Blade Server
Item Function
LAN port Support 10/100/1000 Mbits interface to connect to external device.
COM port Use this port to control or monitor switch blade.
SFP port (On the Small form-factor pluggable port. Allow user to plug in fiber optical module for
Ethernet Switch Blade fiber interface connection.
only)
On/Off Switch (On the To turn on and off the Switch Blade.
Ethernet Switch Blade
only)
Status LED Indicator When lit indicates system fault. (Please call our certified service person to
(On the Ethernet check your system)
Switch Blade Only)
HiGig Expansion Supported by 10 Gbps HiGig Expansion, to interconnect up to 32 Ethernet
Input/Output Switch Blade.
Connector (On the
Ethernet Switch Blade
only)
18
Blade Server
The Correspondent Network
The Correspondent Network
Ethernet Feedthru Blade
Each server blade board supports one LAN port on each Ethernet feedthru blade to connect
external devices. The correspondent LAN port for each server blade board is shown in Figure 9.
Server blade board A supports LAN1, and server blade board B support LAN2…. etc.
Note: When user uses two Ethernet Feedthru blades for both network slots on HS420 series, each server
blade board supports two LAN ports, one on each side of Ethernet feedthru blade.
Figure 9 : The correspondent network on Ethernet feedthru blade
19
Blade Server
Ethernet Switch Blade
When user chooses to use Ethernet switch blade for HS420A series networking, each Ethernet
switch blade supports LAN, SFP (Small Form-Factor Pluggable Port) and HiGig ports. The two
LAN ports support copper interface for connecting to external servers or network switch. The two
SFP ports support various fiber interface connection to external server or network switch. However,
this Ethernet switch blade does not support using LAN and SFP simultaneously. The figure below
shows the relationship between server blade board, switch chip and Ethernet switch blade.
Note: HiGig Input/Output ports are only for Ethernet switch blade stacking. Please see Stacking two
Ethernet Switch Blade on page 32 when user selects two Ethernet switch blades for both networking
slots on HS420 series to chain the Ethernet switch blades.
Figure 10 : The correspondent network on Ethernet switch blade
This concludes Chapter 1. The next chapter covers setting up the HS420 series server.
20
Blade Server
Chapter 2 Getting Started
This chapter provides information for setting up your HS420 series server. Please read the safety
information on page iv. These guidelines will help you work safely while working with the
NexBlade™ with blade server, or other components.
Choosing a Suitable Environment
Choosing a Suitable Environment
You can use your HS420 Series server under a wide range of environmental conditional. However,
to ensure long use and continued high performance, consider the following factors when setting up
your computer:
♦ Set the HS420 series on a flat, stable surface or in a suitable rack. To prevent damage to the hard
disks, avoid using the server where it will be exposed to strong vibration.
♦ Place the HS420 series away from electromagnetic or radio frequency interference (for example,
television/stereo sets, copying machines, and air conditioners).
♦ Avoid using or storing the HS420 series where it will be exposed to extreme temperatures. In particular,
do not leave the server in direct sunlight, over a radiator, or near a hear source for a long period. High
temperature can damage the circuitry.
♦ Avoid exposing the HS420 series to high or low humidity. Extreme humidity can contribute to disk drive
failure.
♦ Do not allow anything to rest on the power cord. Do not place the HS420 series where people can step
on or trip over the cord.
Note: The HS420 series can be operated in either stand-alone mode or daisy chain mode.
21
Blade Server
Setting Up the Server Environment
Setting Up the Server Environment
Choosing a Rack
You will probably want to install your HS420 series in a suitable server rack. Installing the HS420
series in a rack and then organizing a dedicated server room offers many advantages. Computer
server racks occupy a minimum of floor space while maximizing vertical space utilization. Racks
also provide a safe and stable platform for computing equipment. Mounting all your computer and
network equipment in a customized server rack and then centralizing the equipment in a single
room makes for easy maintenance and access.
Two main server racks are available:
Open bay server These racks are easy to customize, and can be expanded to
racks accommodate many types of equipment storage applications.
The open-bay server rack also provides easy access to your
computer hardware for maintenance and troubleshooting
tasks.
These computer racks are more appropriate for secured server
rooms, and are generally more affordable since they do not
have side panels or lockable doors.
Enclosed Enclosed computer cabinets provide better security than their
computer open bay server rack counterparts. The enclosed computer
cabinets cabinets prevent dust and contaminants from reducing the
integrity of the system.
A rack cabinet with a depth of more than 700 mm, excluding the front door depth, is recommended
for the HS420 series. For better heat dissipation, the rear side of the rack cabinet should be open.
22
Blade Server
Server Room Layout
A well-designed server room provides enough space for rack furniture and computer equipment,
and allows for future expansion. Make access to cables and cable connections convenient by
leaving enough room around the server racks or cabinets. Network cables should be stored either
in the ceiling or in the space under a raised floor to prevent tangles and provide a safe working
area.
Provide storage space such as shelves to store instruction manuals, test equipment, software, and
other necessary items. A desktop workspace provides extra convenience and utility to server room
operators.
The HS420 series server enables you to reduce workstation clutter and avoids the necessity of
using multiple workstations by configuring a Keyboard/Video/Mouse (KVM) board.
Managing Cables
Labeled and color-coded cables simplify installation and troubleshooting and make cable
identification easier. Most computer server racks provide some method of cable management,
either through use of cable raceways, metal loops, or closed cable channels. Nylon cable ties are
also an effective way to gather loose cables and organize different wiring segments in the network.
Securing the Server Room
Controlled access to the server room is important to protect your information and equipment.
Implement passwords on all systems, and have locked or card-access entry to all server rooms to
reduce the risk of unauthorized intrusion. Getting computer cabinets that have locks is an effective
deterrent to unauthorized access as well.
23
Blade Server
Attaching the Mounting Rail
Attaching the Mounting Rail
HS420 series server is designed to daisy chaining in the rack mount server environment. Attach
mounting rail onto the server chassis allow user to slide the server out from the rack mount shelve
and give user the ease of operation and maintenance. HS420 series chassis contents 11 mounting
holes to match different manufacturer mounting rails. The mounting rail should sustain at least 50
kg (110lb) to meet the qualification. We strongly recommend using NEXCOM® HS420A Chassis
Side Rail (Part Number: 5050200004). Please contact our NEXCOM® representatives for ordering
information. The below figure shows the mounting holes location:
Figure 11 : HS420 series chassis mounting holes location
When user is installing the mounting rail onto HS420 series chassis, only screw less than 4 mm
long is allowed. Using three screws (such as Flat-head I4x4 screw, which provided by NEXCOM®
HS420A Chassis Side Rail Kit) is recommended to secure the mounting rail.
Figure 12 : Side View of HS420 Series with Mounting Rail
24
Blade Server
Assigning an ID
Assigning an ID
Before you can daisy chain your HS420 series chassis, you must first assign a unique ID to each
chassis by using the chassis identifier dial on the management blade. Refer to Figure 13 and below
instructions:
Figure 13 : Chassis ID Define Dial
1. Turn off the Basic/Advanced Management Blade power supply.
2. Use a screwdriver to turn the ID dial and assign an ID to each HS420 series chassis on the
Basic/Advanced Management Blade: The values on the dial range from 0 to 15. The
configuration of your master chassis ID should be 0. The remaining HS420 series chassis
should have unique ID selections ranging from 1 to 15.
3. Turn on the Basic/Advanced Management Blade power supply.
25
Blade Server
To Use the HS420 Series as a Stand Alone Server
To set the HS420 series as a stand-alone server, set the ID at 0, the default chassis ID number.
To Daisy Chain Several HS420 Series Chassis Within a Rack
To daisy chain the HS420 series in a rack, you must set a specific ID number to each chassis
respectively before chaining them together. Use the Chassis ID Define Dial on the Basic/Advanced
Management Blade to select ID numbers to each HS420 series server. Usually, the master chassis
is always located in the middle area of rack to provide the best operation height. However, upon
user’s convenience, it is not necessary for the master chassis to always be the central one. Follow
these instructions and refer to the illustrations when setting the ID in a daisy chain configuration:
1. Set the master chassis as ID#0.
2. Set the chassis below the master chassis as ID#1.
3. Set the chassis below ID#1 as ID#2.
Continue setting the ID until each chassis has a unique ID number.
For the daisy cable chaining, please refer to Daisy Chaining on the next page.
Case 1 Case 2
26
Blade Server
Daisy Chaining
Daisy Chaining
Daisy chaining is a HS420 series feature that frees up more space and allows data centers to cram
more computing horsepower in the same square footage by stack multiple HS420 series chassis to
share keyboard, mouse and display monitor devices, and to minimize the cabling. This section
illustrates the proper installation procedure when implementing the daisy chain function on your
HS420 series system.
Note: 1. If you are using only one HS420 series server, you may skip reading this section.
2. The default setting of the chassis ID# is “0” meaning that the server is in stand-alone configuration,
or master chassis in daisy chain configuration.
3. A requirement for this daisy chain installation is 68-pin connector cables. These connectors are only
available from NEXCOM.
Basic Management Blade
1. Connect the KVM Daisy Chain cable female connector to the male input daisy chain port
of the upper server.
Figure 14 : Daisy Chain Ports
27
Blade Server
2. Connect the male end of the KVM cable to the female output daisy chain port of the
lower server.
3. Repeat the steps above to the remaining HS420 series servers:
4. Connect KVM dangle cable to Female Output Connector on the master chassis for external
keyboard, mouse and VGA. Please refer to Connecting Peripheral Devices on page 31.
Figure 15 : Daisy chaining HS420 Series Chassis by Basic Management Blade
28
Blade Server
Advanced Management Blade
1. Connect the KVM Daisy Chain cable female connector to the male input daisy chain port
of the upper server.
2. Connect the male end of the KVM cable to the female output daisy chain port of the
lower server.
3. Repeat the steps above to the remaining HS420 series servers:
4. Connect KVM dangle cable to Female Output Connector on the master chassis for external
keyboard, mouse and VGA. Please refer to Connecting Peripheral Devices on the following
page.
Figure 16 : Daisy chaining HS420 Series Chassis by Advanced Management Blade
29
Blade Server
Connecting Peripheral Devices
Connecting Peripheral Devices
The HS420 series is equipped with several interface ports, including serial console port, daisy chain
connectors for connecting peripheral devices to the computer.
Note: The available peripheral devices are keyboard, mouse, display monitor, terminal and system
management station.
Connecting a PS/2 Keyboard, Mouse and Display Monitor
Enable to operate the server, you will need a keyboard and mouse as input device and a display
monitor as an output display device. You can connect the external keyboard, numeric keypad, PS/2
compatible mouse and monitor to the server. The devices are “hot pluggable.” You do not have to
power down the computer to connect these devices. Refer to the following illustration and instructions
to connect a PS/2 keyboard, mouse or display monitor:
1. Place the keyboard, mouse and monitor in the appropriate location.
2. Plug the KVM dangle cable into the Daisy chain output port at the Basic or Advanced Management
blade.
3. Connect the keyboard, mouse into the KVM dangle cable connectors. The green KVM dangle cable
connector is to connect mouse, purple for keyboard.
4. Plug the display monitor’s signal connector into the blue color VGA connector. Secure the screws on
the connector.
5. Plug the monitor’s power cable into a wall outlet.
Turn on the display monitor power and adjust the monitor stand so that you have a good viewing
angle of the screen.
30
Blade Server
Figure 17 : Connecting an external devices by Basic Management Blade
Figure 18 : Connecting an external devices by Advanced Management Blade
31
Blade Server
Connecting LAN Port
Connecting LAN Port
Before plug in the LAN cable into LAN port to connect external devices, please check the location
of the LAN port relevant to each server blade, refer to The Correspondent Network on page 19.
Stacking two Ethernet Switch Blades
Stacking two Ethernet Switch Blades
The Ethernet switch blade supports one 10 Gigabits port for switch-to-switch communication. This
feature allows user stacking two Ethernet switch blades for expanding number of LAN ports. To
stack two Ethernet switch blades, uses 10Gigabits HiGig connectors for blade-to-blade
communication, plug the HiGig cable into “HiGig In” port in one side of Ethernet switch blade board,
then plug the other side of cable into HiGig Out port on the other side of Ethernet switch blade
board. Please see the following figure for detail.
Figure 19 : Stacking two Ethernet Switch Blades
Connecting Management Port on the Management Blade
Connecting Management Port on the Management Blade
On the panel of management blade, there is a RJ-45 jack provides a LAN/serial dual interface port
for system management use. Users can connect the serial port on management station to this port
through null modem cable for local management, or connect the management station to this port
through Ethernet to enable remote management capability. The default port attribute is set to LAN
module, remove LAN interface module from basic management blade if you prefer using serial
port. Refer to the NexCare user’s manual for information on installing the NexCare hardware and
software.
This concludes Chapter 2. The next chapter covers how to turn on the HS420 series.
32
Blade Server
Chapter 3 Turning on the NexBlade™ HS420 Series
Before turning on your server, make sure you are familiar with its features. (Please see Introducing
the HS420 on page 1 for details).
Turning on the Power Supplies
Turning on the Power Supplies
Before turn on the power, use the provided 3 AC power cords to connect your HS420 series chassis
to the power source from the AC wall outlets (step 1 on figure 20). Press the on/off switch on each
power module (step 2 on figure 20) to turn on the power supplies. Press the chassis power supply
on/off switch located at the rear HS420 (step 3 on figure 20) to turn on power to the chassis. Then
turn on the Basic/Advanced Management Blade on/off switch (step 4 on figure 20) enable the KVM
control panel. Refer to the illustration below:
Note: The A power cord supplies power to “i” power modules. The B power cord supplies power to ”ii” power
modules, and the C power cord supplies power to “iii” power modules.
Figure 20 : Turning on the HS420 series power supplies
33
Blade Server
Warning! Never turn off or reset your server while the hard disk is in use and the hard disk drive (HDD) status is
lit; doing so can result in loss of your data. Always wait at least five seconds after turning off your
server before turning it back on; turning the power on and off in rapid succession can damage the
server’s electrical circuitry.
Note! The best kind of AC power source
to connect the server is a UPS
(Uninterruptible Power Supply).
Lacking this, use a power strip with
a built in surge protector. Do not
use inferior extension cords as this
may result in damage to your
computer.
Software Installation
Software Installation
HS420 series does not include build-in CD-ROM or Floppy Disk Drive. To install software, three
easy methods are provided as below:
Using USB Device
Each server blade supports one USB outlet in front, enables user to connect external devices, such
as USB compatible CD-ROM or Floppy Disk Drive.
Booting from LAN
Boot from LAN function enables user to install software through Network.
34
Blade Server
Using NEXCOM® NEXIK™
Pull out a server blade from the HS420 series chassis and insert NEXCOM® NEXIK 410 into the
server blade slot. Using the CD-ROM and floppy disk drive provided on the NEXIK 410 to install
software.
Note: NEXIK 410 is an optional accessory, please contact NEXCOM representative for more information.
NEXIK On/Off Switch
CD-ROM/FDD
Lock LED
Slim-type CD-ROM
Slim-type FDD drive
Figure 21 : NEXCOM NEXIK 410
Item Function
NEXIK On/Off Switch To turn on and off the NEXIK module.
CD-ROM/FDD Lock Indicate whether CD-ROM/FDD drives have been locked on a selected unit
LED chassis in the daisy chain environment.
Slim-type CD-ROM A CD-ROM drive unit
Slim-type FDD drive A Floppy disk drive unit
35
Blade Server
Using the Server Blade Board Button and KVM Control Panel
Using the Server Blade Board Button and KVM Control Panel
After you have turned on the chassis power (refer to Turning on the HS420 Series on page 34), and
set appropriate ID for each chassis (refer to Assigning an ID on Page 26) you can use the switch
and buttons on Server blade boards and KVM Control Panel to operate the server. Refer to the
following instructions:
1. Turn the power on to the
Server Blade boards you
want to use by pressing the
power button on each blade
server.
Figure 22 : Turning on the Server
Blade and KVM Control Panel
2. The Server Blade board
power LEDs illuminate with
a blue color indicating that
they are turned on:
Figure 23 : Server Blade Board
Power LEDs
36
Blade Server
3. Press the upper
system selected
button to select a
Server Blade board to
the left. Press the
lower system
selected button to
select a Server Blade
board to the right.
The Server Blade
boards system
Figure 24 : Selecting a Server Blade Board
selected LED
by System Right/Left Selection Buttons
illuminates with a
green color when it is
selected:
4. Another way to select
Server Blade Board is
by pressing the KVM/
Access button on the
Server Blade board.
Again, the Server
Blade boards system
selected LED
illuminates with a
green color when it is
selected:
Figure 25 : Selecting a Server Blade
Board by KVM/Access Button
37
Blade Server
5. Press the upper
Note: The server must be daisy chained before you
chassis selected
can select a different chassis. Refer to Daisy
button to select a
Chaining on page 28.
chassis located
above this one. Press
the lower chassis
select button to
select a chassis
located below this
one. The chassis
selected LED
illuminates with a
blue color when the
chassis is powered
on. It turns green
color when the Figure 26 : Selecting a Different Chassis
chassis is selected.
6. To lock the operation
server blade, press
the master chassis
lock button when a
blade server on the
master or slave
chassis is selected.
Press the lock button
again to unlock the
server blade.
Figure 27 : Server Blade Lock Button
38
Blade Server
7. If a component fails,
the alarm LED
illuminates. When this
happens, use the
Nexcare™ Monitoring
software to locate the
fault.
Figure 28 : System Fault Alarm LED
8. The system/HDD
Status LEDs
illuminates with a
flashing orange color
when the HDD is
being accessed. It
turns red color
indicates the system
has errors. When this
happens, use the
Nexcare™ Monitoring
software to locate the
fault. No error and no
Figure 29 : System/HDD Status LEDs
HDD access when
the LEDs are not
illuminated.
39
Blade Server
9. The LAN indicator
LEDs illuminate with
green color when the
LAN ports are linked.
The flashing green
LEDs indicate the
LAN ports are being
active.
Figure 30 : LAN Indicator LEDs
This concludes chapter 3. The next chapter covers “Hot Swapping NexBlade™ HS420 Series
Components.”
40
Blade Server
Chapter 4 Hot-Swapping Components
This chapter guides you through the process of hot swapping the HS420 series Server Blade
boards, KVM control panel, power modules, management blade, dual network hub and cooling fan
trays.
Hot-Swapping Server Blade Board
Hot-Swapping Server Blade Board
Follow these instructions to hot-swap a server blade board:
1. Power off the server blade.
Note: Wait at least five seconds after turning off the power before removing the blade from the chassis.
2. Loosen the two screws that fasten the blade system tray to the HS420 series chassis. Do not
remove the screws.
1
A
2
3
B
Figure 31 : Hot-Swapping a Server Blade board
41
Blade Server
3. Slide the server blade out of the chassis.
4. Slide the blade backs into the HS420 series chassis and replace the two screws on its front
panel.
Hot-Swapping the KVM Control Panel
Hot-Swapping the KVM Control Panel
Follow these instructions to remove the KVM Control Panel:
1. Loosen the knot on the top and bottom of the KVM Control Panel that fastens the KVM Control Panel onto
the HS420 chassis. Do not remove the knot (Figure 32).
Figure 33 : Hot-Swapping KVM
Figure 32 : Hot-Swapping KVM
Control Panel (2)
Control Panel (1)
2. Slide the KVM Control Panel out of the chassis (Figure 33).
3. Slide the blade back into the HS420 series chassis and fasten the knot back to the server case.
42
Blade Server
Hot-Swapping Power Supply Modules
Hot-Swapping Power Supply Modules
Rear HS420 series server contents seven power supply modules. These modules are secured to
the chassis by a locking handle and a locking strip located on the bottom of the module.
Figure 34 : Hot–Swapping Power Supply Modules (1)
Note: When the power supply module is turned on, and the condition of the module is normal, the power module
status LED illuminates green. A red LED indicates the power supply has failed. The light is off when power
module is turned off.
Follow these instructions to hot-swap a power module:
1. Unscrew both sides of locking screws to take off the locking strip (Figure 35).
2. Press the lower handle up on the power supply module (A in Figure 36)
3. Pull the power module by the handle and remove it (B in Figure 36)
4. Push the power module back to the system
5. Press the chassis power supply on/off switch promptly to turn on the power module (C in Figure
36)
Note: If you press the chassis power supply on/off switch (C in Figure 36) more than 4 seconds, the whole HS420
series system will be turned off.
Figure 35 : Hot–Swapping
Figure 36 : Hot–Swapping Power
Power Supply Module (2)
Supply Modules (3)
43
Blade Server
Hot-Swapping Management Blade
Hot-Swapping Management Blade
Basic Management Blade
To hot-swap the Basic Management Blade, please follow the instructions below:
1. Unscrew both sides of locking screws to take off the locking strip (Figure 37).
2. Press down the power switch on the basic management blade to turn off the power (Step 1 in
Figure 38).
3. Unscrew the two locking knots (Step 2 in Figure 38).
4. Pull out the management blade (Step 3 in Figure 39).
5. Push the management blade back to the system and fasten the two locking knots.
6. Turn on the management blade power.
Figure 37 : Hot-Swapping Basic Management Blade (1)
Figure 38 : Hot–Swapping Figure 39 : Hot–Swapping
Basic Management Blade (2) Basic Management Blade (3)
44
Blade Server
Advanced Management Blade
To hot-swap the Advanced Management Blade, please follow the instructions below:
1. Press down the power switch on the advanced management blade to turn off the power (Step
1 in Figure 40).
2. Unscrew the two locking knots (step 2 in Figure 40).
3. Pull out the management blade (step 3 in Figure 40).
4. Push the management blade back to the system and fasten the two locking knots.
5. Turn on the management blade power.
Figure 40 : Hot–Swapping Advanced Management Blade
Hot-Swapping Cooling Fan Trays
Hot-Swapping Cooling Fan Trays
The cooling fan trays on the rear HS420 series are easy for hot-swap, please refer to the following
instructions:
1. Pull the cooling fan tray out by the handle
2. Push it back on
Figure 41 : Hot-Swapping Cooling Fan Trays
45
Blade Server
Hot-Swapping Ethernet Feedthru Blade and Ethernet Switch
Hot-Swapping Ethernet Feedthru Blade and Ethernet Switch
Blade
Blade
The hot-swap technology is also support Ethernet Feedthru Blade and Ethernet Switch Blade.
Please follow the instructions below:
1. Loosen the locking knots on the two side of the Ethernet Feedthru Blade/Ethernet Switch Blade
(Step 1).
2. Pull the Ethernet Feedthru/Ethernet Switch Blade out by the handle (step 2).
3. Push it back on
Figure 42 : Hot-Swapping Figure 43 : Hot-Swapping
Ethernet Feedthru Blade Ethernet Switch Blade
This concludes chapter 4. Next chapter describes the HS420 series BIOS.
46
Blade Server
Chapter 5 NexBlade™ HS420 Series BIOS
This chapter explains how to use the BIOS (Basic Input and Output System) Setup program for the
Blade system boards that come with the HS420 series server.
About the BIOS
About the BIOS
The mainboard employs the latest Award BIOS CMOS chip with support for Windows Plug and Play.
This CMOS chip contains the ROM Setup instructions for configuring the mainboard’s BIOS. The
BIOS Setup program is a menu-driven utility that enables you to make changes to the system
configuration and tailor your system to suit your individual work needs. A ROM-based configuration
utility displays the system’s configuration status and provides you with a tool to set system
parameters. These parameters are stored in non-volatile, battery-backed-up CMOS RAM that
saves this information even when the power is turned off. When the system is turned back on, it is
configured with the values found in CMOS.
Using the BIOS menus, you can easily configure such items as:
• Hard drives, diskette drives, and peripherals
• Video display type and display options
• Password protection to prevent unauthorized use
• Power management features
The settings made in the Setup program intimately affect how the server performs. It is important,
therefore, first to try to understand all the Setup options, and second, to make settings appropriate
for the way you use the server.
W Wh he en n t to o R Ru un n B BIIO OS S
The program should be executed when you perform any of the following actions:
• Change the system configuration
• Change the Setup program in response to a configuration error detected by the system
• Reset the system clock
• Set the CPU clock speed to run automatically either fast or slow
• Redefine the communication ports to prevent conflicts
• Make changes to the Power Management configuration
• Change the password or make other changes to the security setup
Normally, CMOS setup is needed when the system hardware is inconsistent with the information
contained in the CMOS RAM, the CMOS RAM has lost power, or the system features need to be
changed.
47
Blade Server
Getting Help
Getting Help
Main Menu
The on-line description of the highlighted setup function is displayed on the right-hand side or at the
bottom of the screen.
Status Page Setup Menu/Option Page Setup Menu
Press allows you to enter Setup. Another way
to enter Setup is to power on the computer and wait for the following message during the POST:
TO ENTER SETUP BEFORE BOOT
PRESS KEY
Press the key or press Ctrl+Alt+Esc to enter Setup:
Phoenix - Award WorkstationBIOS CMOS Setup Utility
Standard CMOS Features Set Supervisor Password
Boot Device Sequence Set User Password
Integrated Peripherals Save & Exit Setup
Power Management Setup Exit Without Saving
Load Optimized Defaults
Esc : Quit F9 : Menu in BIOS ↑ ↓ → ← : Select Item
F10 : Save & Exit Setup
Time, Date, Hard Disk Type . . .
Figure 44 : Setup Utility Main Screen
49
Blade Server
The following table describes the items in this menu.
Menu Item Description
Standard CMOS Features Use this menu for basic system configuration.
Use this item to specify where the system looks for an operating
Boot Device Sequence
system.
Integrated Peripherals Use this menu to specify your settings for integrated peripherals.
Power Management Setup Use this menu to specify your settings for power management.
Load Optimized Defaults Use this menu to load the BIOS default values, i.e., factory
settings for optimal performance system operations. While
Award has designed the custom BIOS to maximize
performance, the factory has the option to change these defaults
to meet their needs.
Set Supervisor Password Enables you to change, set, or disable the supervisor or user
password.
Set User Password Enables you to change, set, or disable the supervisor or user
password.
Save & Exit Setup Saves CMOS value changes to CMOS and exits setup.
Exit Without Saving Ignores all CMOS value changes and exits setup.
50
Blade Server
Standard CMOS Features
Standard CMOS Features
Selecting Standard CMOS Features on the main program screen displays the following menu:
Phoenix - Award WorkstationBIOS CMOS Setup Utility
Standard CMOS Features
Date (mm:dd:yy) Tue, July 11 2000 Item Help
Time (hh:mm:ss) 12 : 8 : 59
Menu Level
IDE Primary Master [ None]
Change the day, month,
IDE Primary Slave [ None]
year and century.
IDE Secondary Master
IDE Secondary Slave [ None]
Video [EGA/VGA]
Halt On [No Errors]
Base Memory 640K
Extended Memory 31744K
Total Memory 32768K
↑ ↓ → ← : Move Enter : Select +/-/PU/PD:Value: F10: Save ESC: Exit F1:General
Help F5:Previous Values F6:Fail-Safe Defaults F7:Optimized Defaults
Figure 45 : Standard CMOS Setup Screen
The Standard CMOS Setup utility is used to configure the following features:
Date: Month, Day, Year
Time: Hour, minute, and second. Use 24-hour clock format (for P.M., add 12 to the hour; for
example, you would enter 4:30 p.m. as 16:30).
IDE Primary/Secondary Master/Slave: Your computer has two IDE channels (Primary and Secondary)
and each channel can be installed with one or two devices (Master and Slave). Use these items to
configure each device on the IDE channel.
51
Blade Server
Press
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the NEXKVM420F have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods