Elite.Parts chervon right Manufacturers chervon right N chervon right NEWMAR chervon right NHS-24-100
About product Features Datasheet FAQ

NEWMAR NHS-24-100

Description

Newmar NHS-24-100 Rectifier - NHS24100 hot swap modular rectifier, INPUT VOLTAGE (VDC) 24 VOLTS, OUTPUT VOLTAGE (VAC) 10

Part Number

NHS-24-100

Price

Request Quote

Manufacturer

NEWMAR

Lead Time

Request Quote

Category

PRODUCTS - N

Features

Datasheet

pdf file

NHS-24-10-12667790330.pdf

678 KiB

Extracted Text

Compac NHS Rack Systems Rectifiers and Shelves Compac Series Compac Series NHS Rectifiers and Shelves NHS Rectifiers and Shelves 208Vin SINGLE OR THREE PHASE Description Features ◗Compact 3U height. NHS rectifiers and shelves can ◗24 and 48 volt rectifiers. be configured with other ◗50 amp rectifier at 48V. Compac Series distribution, ◗100 amp rectifier at 24V. controller, and temperature ◗180-264 VAC single-phase or three-phase inputs. compensation panels. These ◗Hot-swappable rectifiers are true plug-and-play. No adjustments required. rectifier/shelf systems are 3 ◗High power density (9.8W/in ). designed for use in both indoor ◗High reliability, >700,000 hours MTBF. racks and outdoor cabinets. ◗Power Factor Correction (PFC). NHS Series rectifiers are ◗Active current sharing. hot-swappable and provide a ◗Near unity power factor eliminates excessive input harmonic current draw, which minimizes cable and fuse/circuit breaker input sizing. complete set of interface signals. ◗International Standards Compliance. Rectifier and Shelf Selection NPS4-S NPS3-S NPS3-S-1-FM NHS24/100 NHS48/50 Shelf Shelf Shelf Rectifier Rectifier Output Voltage Dependant Dependant Dependant 25 to 29VDC 51 to 59VDC on rectifier on rectifier on rectifier (24V optional) (48V optional) Output Current 200A @ 48V 150A @ 48V 150A @ 48V 400A @ 24V 300A @ 24V 300A @ 24V 100A 50A (4 rectifiers) (3 rectifiers) (3 rectifiers) Input Voltage 180-264 VAC 180-264 VAC 180-264 VAC 180-264 VAC 180-264 VAC Single Phase Single or Three Phase Single Phase Single Phase Single Phase 60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz Input Current 60A @ 230V 45A @ 230V 45A @ 230V 15A @ 230V 15A @ 230V Soft Start See Rectifier See Rectifier See Rectifier 30A peak, max 5 mS 30A peak, max 5 mS Input Breaker Rating 4 x 40A 3 x 40A 100A N/A N/A (1 per rectifier feed) (1 per rectifier feed) Full Load Efficiency N/A N/A N/A 86% 86% BTU/Hr (full load) N/A N/A N/A 1255 1255 Input Configuration 4 inputs 3 inputs 1 set of input 1 per rectifier 1 per rectifier studs feeds N/A N/A max. 8 AWG wire max. 8 AWG wire all rectifiers Mounting Mounting brackets Mounting brackets Mounting brackets recessed 4" recessed 4" flush with N/A N/A from front of shelf from front of shelf front of shelf Width 21.5", mounts in 17.5", mounts in 17.5", mounts in 5" 5" 23" rack 19" rack 19" rack Blank Panel NHS-BP NHS-BP NHS-BP N/A N/A Compac Series Compac Series NHS Rectifiers and Shelves NHS Rectifiers and Shelves Rectifier Measurement Test Points DC-OK AC-OK LED Bargraph Display of Output Current Hot-Swap Shelf Connection Compac Series rectifiers and shelves are available in a complete Compac power plant or subassemblies for cabinet applications. Compac Series Compac Series NHS Rectifiers and Shelves NHS Rectifiers and Shelves TECHNICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS: AC Input Range: 180 - 264VAC - three-phase optional Power Factor: >0.99 (50 - 100% load) AC Transient: 3000V, 2 Joules Voltage Regulation: +/- 0.4% Transient Response: +/- 0.4% at load variations 10-90% or 90-10%, recovery time 10 mS Load Sharing: 5% of nominal current Ripple: <1% pk - pk Radiated RFI EN 50081-1 PROTECTION: Overcurrent 100-105% constant current type. Automatic recovering upon removal of fault, short circuit current <110% full load. Overvoltage Latching high voltage shutdown @ 60VDC ±1% Overtemperature Rectifier will shut down if temperature reaches unsafe level, Restart is automatic STATUS & ALARMS: Status: Green LED indicates input power within acceptable range Red LED indicates overvoltage shutdown or rectifier alarm Alarms: High voltage, low voltage, loss of AC, rectifier failure, minor and major alarm MECHANICAL SPECIFICATIONS: Cooling Fan cooled Weight Rectifier: 12.6 lbs, NPS3 Shelf: 21 lbs, NPS4 shelf: 24 lbs Dimensions (H x W x D) Rectifier: 5" x 5" x 12.25" (12.7cm x 12.7cm x 31.1cm) NPS3: 3U 5.25" x 17.5" (13.3cm x 44.5cm) + mounting ears wide x 16" max. depth (40.6cm) NPS4: 3U 5.25" x 21.5" (13.3cm x 54.6cm) + mounting ears wide x 16" max. depth (40.6cm) ENVIRONMENTAL: Altitude Rating: 13000 ft., derate 7°C/1000 ft above 8000 feet Audible Noise 60 dBA Ambient Temperature -25 to +50°C, -40°C to +85°C Storage Humidity 0% to 95%, non-condensing COMPLIANCE: EMI FCC Part 15, class A; EN55022, Level A; Bellcore GR-1089-CORE Safety UL 1950, CSA 22.2 #950 TUV EN60950 Note: All specifications are subject to change without notification. www.power-one.com Revised: 6/01 CPR601-A Compac NHS Rack Systems Rectifiers and Shelves Compac Series Compac Series Compac Rack Systems Compac Rack Systems 24VDC @ 800 AMP SYSTEM 48VDC @ 400 AMP SYSTEM 48VDC @ 1200 AMP SYSTEM Bottom of frame open for user 5 battery trays for 100 to Rear connection point for external installed equipment. 150 Ah battery reserve strings. battery strings. Description Features Compac power plants are modular systems designed for ◗Modular systems from 50 to 1200 amps. applications requiring 50 to 1200 amps. An almost ◗24 or 48V outputs. limitless combination of rectifiers, breaker panels, and battery shelves is available. Stand-alone configurations ◗180-264 VAC single or three-phase inputs. with up to 750 Ah of battery backup are available. Each rack can hold up to 24 rectifiers or a maximum of five◗Rack widths of 19" or 23". battery trays. Systems can be ordered with ultimate ◗Hot-swappable rectifiers. capacity for future addition of rectifiers and batteries. ◗Small footprint for where real estate is at a premium. Standard features include timer-controlled equalize and battery test functions, current and voltage display meters, ◗Scalable N+1 redundancy with current sharing. LED’s for local alarm indications, user-programmable alarm set points, and a full complement of form “C”◗Power Factor Correction (PFC). alarm contacts for remote monitoring. Optional features ◗Extensive monitoring capabilities. include low voltage disconnect, complete battery systems, and battery temperature compensation.◗Options include integrated battery systems and extensive breaker and fuse layouts. The Compac systems distribution architecture can be designed for load shedding during power outages, ◗A single seven foot rack can provide distribution, allowing the critical loads to stay up longer on battery 400 amps of rectifiers, and 750Ah of batteries. power by eliminating the non-critical equipment loads earlier in the discharge cycle.◗International Standards. LOW VOLTAGE DISCONNECT An optional low voltage disconnect provides protection against deep discharge of the batteries by disconnecting the battery from the load at a user-specified cut-out voltage. Reconnection of the battery is automatic upon return of AC to the rectifier. A front panel mounted Emergency Power Off (EPO) switch is provided for emergency or service disconnection of the batteries. Remote contacts for the EPO switch are provided to enable the installer to place a remote switch at a more convenient location, as many city fire codes require. BREAKER PANELS Breaker panel options include: ◗Twenty positions for 5 to 100 amp breakers. ◗Two positions for 125 to 250 amp breakers. ◗A single position 450 amp or 525 amp breaker. DIGITAL METER,ALARM,AND CONTROL PANEL The Digital Meter, Alarm, and Control (DMAC) panel monitors system bus voltage and load current, and provides a variety of alarm and control functions. DMAC features include: ◗Single point system voltage adjust. ◗Programmable timer for battery test or equalization. ◗Front panel LED’s for alarms as designated below. ◗User-adjustable set points for under/over voltage and low voltage disconnect. ◗Digital meters and test points monitor plant voltage and current. Equalize and Timer System Normal/Bypass, Equalize, Equalize, Major alarm, System voltage Digital Digital System amperage battery test reset voltage and OV/UV alarm undervoltage minor alarm, test points Voltmeter Ammeter test points timer button adjust pot Equalize/Battery and battery and overvoltage rectifier fail, test switches test LED’s alarm setting breaker alarm, and adjust pots LVD open LED’s Compac Series Compac Series Compac Rack Systems Compac Rack Systems DMAC BATTERY TEST AND EQUALIZATION Battery testing is performed by setting the desired length of time and activating the test cycle. During the test cycle, the controller automatically decreases the rectifier voltage in order to transfer the load onto the batteries. Measurement of battery voltage and current may be taken to determine health of the battery string. The system will automatically return to normal rectifier float voltage when the test is completed. Battery equalization is performed by setting the desired length of time and activating the equalization cycle. During the cycle, the controller automatically increases the rectifier voltage to the user-programmable level in order to equalize the battery voltage. TEMPERATURE COMPENSATION The temperature compensation panel works in conjunction with the DMAC controller. Temperature compensation automatically adjusts the float voltage according to the ambient temperature. Alarms include temperature delta, which indicates battery thermal runaway and sensor failure. In the event of sensor or panel failure, the compensation defaults to the normal float voltage set by the controller. COMPAC SERIES RECTIFIERS ◗High power density allows for more room for other system components. ◗Near unity power factor eliminates excessive input harmonic current draw, which minimizes cable and fuse/circuit breaker input sizing. ◗Hot-swappable, true plug-and-play. No adjustments required. See the Compac Rectifier data sheet for further information. LED Bargraph Display Rectifier Measurement of Output Current Test Points DC-OK AC-OK Compac Series Compac Series Compac Rack Systems Compac Rack Systems TECHNICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS: Input Voltage 180-264 VAC, single or three-phase, 50-60 Hz Input Current 15 amp per rectifier at full load, 30 amp peak Input Breaker Rating 40 amp per rectifier Input Wire Size 8 AWG maximum DC Bus Rating 800 or 1200 amp options Maximum Current Rating per Breaker Panel 400 amps Low Voltage Disconnect (LVD): Contactor Rating 800 or 1200 amp options Disconnect Voltage User adjustable, factory set @ 21V for 24V systems, 42V for 48V systems LVD Disconnect Range 34 to 51VDC for 48V systems, 18 to 26VDC for 24V systems Reconnect Voltage Approx. 6.5V above disconnect voltage (4.7V for 24V systems) DMAC Controller: Digital Meters 3.5 digits, ±2% accuracy UV/OV Adjustment 22V/29V for 24VDC ±1.5V 44V/58V for 48VDC ±1.5V Equalization & Battery Test Timer Range 0.5 seconds to 130 hours Current Measurement DC Shunt 1200A:50mA Rectifier: See Compac Rectifier data sheet Battery Trays Option: Optional Battery Fuses Fuses rated at 225 amps Connection Cabling provided, includes Anderson Quick-Disconnect connectors. MECHANICAL SPECIFICATIONS: Width 19" or 23" Battery Tray Depth 21", 25" or 29" Floor Mounting Mounting holes provided, pattern varies with configuration, contact factory Color Texture Black Gloss (Shelf & Rectifiers) ENVIRONMENTAL: Temperature Range 0- 50°C operating, -50 to +85°C storage Humidity 10-90% RH, operating, 5-95% storage, non-condensing Temperature Coefficient ±0.0008%/°C from 0-50°C after one hour warm-up Altitude Range 13,000 ft., derate 7°C/1000 ft. above 8,000 ft. Heat Dissipation /BTU per Hour per Rectifier 1,255 BTU’s per hour at full load Note: All specifications are subject to change without notification. www.power-one.com Revised: 6/01 CPS601-A Advanced Product Release CPA SERIES - 250 WATT ® The AC input CPA250-4530 is a hot-swap, CompactPCI Remote sense and active current share on the +5, +3.3, ® power supply which is fully compliant to the PICMG 2.11 and +12 volt outputs along with ORing FETs allow these units to Power Interface Specification using a standard Positronic 47-pin be used in redundant, hot-swap applications. connector. Extra-high current density using innovative Power- The CPA250-4530 is feature rich, meets international One EDGE technology allows this unit to deliver up to 40 safety standards, and displays the CE Mark for the Low Voltage amperes on both the +5 and +3.3 volt outputs at 50ºC. Directive (LVD). FEATURES • Wide Input Range (85-264 VAC)  Delivers 40A for the +5V and +3.3V Outputs (No Restrictions)  Single-wire Current Share on Outputs V1, V2, and V3  Remote Sense on Outputs V1, V2, and V3  Overtemperature, Overvoltage, and Overcurrent Protection  Input Good and Power Fail LED Indicators  Power Fail and Temperature Warning Signals  Inhibit and Enable Inputs ® ®  Fully Compliant to PICMG 2.11 CompactPCI Specification  Extra-High Current Density in Industry-Standard 3U x 8HP x 160mm Package AC INPUT MODEL SELECTION CHART OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE MODEL VOLTAGE RANGE CURRENT REGULATION REGULATION %pk-pk (NOTE 1) +5V N/A 40A 0.5% 1% 2% CPA250-4530 +3.3V N/A 40A 0.5% 1% 2% +12V N/A 5.5A 0.5% 1% 1.3% -12V N/A 1.5A 0.5% 1% 1.3% NOTES: 1) Maximum peak-to-peak expressed as a percentage of output voltage, 20 MHz bandwidth. INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency 47 63 Hz Hold-up Time 20 ms Input Protection Non-user serviceable, internally-located input line fuse. Inrush Surge Current Internally limited by thermistor and electronic switch. 30 A Operating Frequency Switching frequency of main output transformer. 125 145 kHz CompactPCI and PICMG are registered trademarks of the PCI Industrial Computer Manufacturers Group. REV. 10/25/01 1 CPA SERIES - 250 WATT OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full rated load, 115 VAC. 80 % Minimum Load; V1, V2, V3 Minimum load required to maintain regulation with no load on V4. None A Minimum Load, V3 Minimum load on V3 required to maintain regulation on V4. 50% OF V4 Load A Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart Output Power 250 LFM forced-air cooling. 200 W Output Power 400 LFM forced-air cooling. 250 W Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Regulation Varies by output. Total regulation includes: line changes over the specified See Model Selection Chart input range, changes in load starting at 50% load and changing to 100% load. Turn-on Delay Time required for initial output voltage stabilization. 150 ms Initial Setting Accuracy ±1% INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Latch style overvoltage protection. 120 130 %Vnom Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Power Fail (FAL#) TTL compatible signal, open collector active low signal. Indicates any output below 90% and/or a low input <85VAC. Current Share Accuracy of shared current with up to 6 parallel units. Single wire current share on V1, V2, and V3. 10 % Remote Sense Available on V1, V2, and V3. Total voltage compensation for cable losses with 150 mV respect to the main output. Inhibit (INH#) TTL-compatible signal inhibited with GND or TTL "0". Enable (EN#) Contact closure to external ground to start unit. On shortest pin (last make, first break). Overtemperature Warning (DEG#) Provides warning when power supply temperature exceeds rating. TTL-compatible open. Front Panel LED Status Indicators Input OK (Green), Output Failure (Red). SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. cUL1950. Approved EN60950 (TÜV). Dielectric Withstand Voltage Input to Output per EN60950. 4243 VDC Electromagnetic Interference EN55022 / CISPR 22 - Conducted. A Class Radiated. A ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 3. ±2 kV Input Surge Per EN61000-4-5, level 3. Line to Line 1 kV Line to Ground 2 Conducted Disturbance Per EN61000-4-6, level 2. 3V Insulation Resistance Input to Output. 10 M� ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft. Non-Operating. 40k ASL Ft. Operating Temperature With 400 LFM forced-air cooling At 100% load: 0 50 °C Derate linearly above 50°C by 2.5% per °C. At 50% load: 70 °C Storage Temperature -40 85 °C Relative Humidity Non-Condensing. 5 95 %RH Shock Peak acceleration. 20 GPK Vibration Random vibration, 10 Hz to 2 kHz, 3 axis. 6 GRMS 2 CPA SERIES - 250 WATT OVERALL SIZE: 5.07"H x 1.60"W x 6.40"D (128.7mm x 40.6mm x 162.5mm) WEIGHT: 1.75 lb (0.8 kg) 6.671" (169.4mm) 6.399" (162.5mm) 0.1" (2.54mm) 3U x 8HP 1.6" (40.6mm) Tolerances ± 0.012" (0.3mm) unless otherwise indicated. 3 0.26" (6.61mm) 3.74" (95.0mm) 0.507" (12.88mm) 3.937" (100.0mm) 5.067" (128.7mm) CPA SERIES - 250 WATT PIN ALLOCATION CHART PIN-LENGTH SIGNAL PIN-LENGTH SIGNAL PIN DESCRIPTION PIN DESCRIPTION TYPE (NOTE 1) NAME TYPE (NOTE 1) NAME 1-4 M V1 V1 OUTPUT 32 M NC NOT CONNECTED 5-12 M RTN V1 and V2 RETURN 33 M V2 SENSE V2 REMOTE SENSE 13-18 M V2 V2 OUTPUT 34 M S RTN SENSE RETURN 19 M RTN V3 RETURN 35 M V1SHARE V1 CURRENT SHARE 20 M V3 V3 OUTPUT 36 M V3SENSE V3 REMOTE SENSE 21 M V4 V4 OUTPUT 37 M NC NOT CONNECTED 22 M RTN SIGNAL RETURN 38 M DEG# DEGRADE SIGNAL 23 M RESERVED RESERVED 39 M INH# INHIBIT 24 M RTN V4 RETURN 40 M NC NOT CONNECTED 25 M NC NOT CONNECTED 41 M V2SHARE V2 CURRENT SHARE 26 M RESERVED RESERVED 42 M FAL# FAIL SIGNAL 27 S EN# ENABLE 43 M NC NOT CONNECTED 28 M NC NOT CONNECTED 44 M V3SHARE V3 CURRENT SHARE 29 M NC NOT CONNECTED 45 L CGND CHASSIS GROUND 30 M V1SENSE V1 REMOTE SENSE 46 M ACN AC INPUT NEUTRAL 31 M NC NOT CONNECTED 47 M ACL AC INPUT LINE NOTE 1) L = Long-Length Pins, M = Medium-Length Pins, S= Short-Length Pins NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 4 Advanced Product Release CPD SERIES - 250 WATT The DC input CPD250-4530 is the first in a series of hot- Remote sense and active current share on the +5, +3.3 and ® swap, CompactPCI power supplies that are fully compliant to the +12 volt outputs along with ORing FETs allow these units to be ® PICMG 2.11 Power Interface Specification using a standard used in redundant, hot-swap applications. Positronic 47-pin connector. Extra-high current density using The CPD250-4530 is feature rich, meets international safety innovative Power-One EDGE technology allows this unit to standards, and displays the CE Mark for the Low Voltage deliver up to 40 amperes on both the +5 and +3.3 volt outputs at Directive (LVD). 50ºC. FEATURES • Wide Input Range (36-75 VDC)  Delivers 40A for the +5V and +3.3V Outputs (No Restrictions)  Single-wire Current Share on Outputs V1, V2, and V3  Remote Sense on Outputs V1, V2, and V3  Overtemperature, Overvoltage, and Overcurrent Protection  Input Good and Power Fail LED Indicators  Power Fail and Temperature Warning Signals  Inhibit and Enable Inputs ® ®  Fully Compliant to PICMG 2.11 CompactPCI Specification  Extra-High Current Density in Industry-Standard 3U x 8HP x 160mm Package DC INPUT MODEL SELECTION CHART OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE MODEL VOLTAGE RANGE CURRENT REGULATION REGULATION %pk-pk (NOTE 1) +5V N/A 40A 0.5% 1% 1.2% CPD250-4530 +3.3V N/A 40A 0.5% 1% 2% +12V N/A 5.5A 0.5% 1% 1% -12V N/A 1.5A 0.5% 1% 1% NOTES: 1) Maximum peak-to-peak expressed as a percentage of output voltage, 20 MHz bandwidth. INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - DC Continuous input range. 36 75 VDC Hold-up Time From 48 VDC Input. 4 ms Input Current At full rated load; 36 VDC, 48 VDC. 7.6, 5.4 A Input Protection Non-user serviceable, internally-located input line fuse. Inrush Surge Current Internally limited by thermistor and electronic switch. 12 A Operating Frequency Switching frequency of main output transformer. 125 145 kHz Input Transient Protection Varistor. CompactPCI and PICMG are registered trademarks of the PCI Industrial Computer Manufacturers Group. REV. 12/07/01 1 CPD SERIES - 250 WATT OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full rated load, 48 VDC Input. 80 % Minimum Load; V1, V2, V3 Minimum load required to maintain regulation with no load on V4. None A Minimum Load, V3 Minimum load on V3 required to maintain regulation on V4. 50% OF V4 Load A Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart Output Power 250 LFM forced-air cooling. 200 W Output Power 400 LFM forced-air cooling. 250 W Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Regulation Varies by output. Total regulation includes: line changes over the specified See Model Selection Chart input range, changes in load starting at 50% load and changing to 100% load. Turn-on Delay Time required for initial output voltage stabilization. 150 ms Initial Setting Accuracy ±1% INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Latch style overvoltage protection. 120 130 %Vnom Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Power Fail (FAL#) TTL compatible signal, open collector active low signal. Indicates any output below 90% and/or a low input <36VDC. Current Share Accuracy of shared current with up to 6 parallel units. Single wire current share on V1, V2, and V3. 10 % Remote Sense Available on V1, V2, and V3. Total voltage compensation for cable losses with 150 mV respect to the main output. Inhibit (INH#) TTL-compatible signal inhibited with GND or TTL "0". Enable (EN#) Contact closure to external ground to start unit. On shortest pin (last make, first break). Overtemperature Warning (DEG#) Provides warning when power supply temperature exceeds rating. TTL-compatible open. Front Panel LED Status Indicators Input OK (Green), Output Failure (Red). SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. cUL1950. Approved EN60950 (TÜV). Dielectric Withstand Voltage Input to Output per EN60950. 4243 VDC Electromagnetic Interference EN55022 / CISPR 22 - Conducted. A Class Radiated. A ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 3. ±2 kV Input Surge Per EN61000-4-5, level 3. Line to Line 1 kV Line to Ground 2 Conducted Disturbance Per EN61000-4-6, level 2. 3V Insulation Resistance Input to Output. 10 M� ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft. Non-Operating. 40k Operating Temperature With 400 LFM forced-air cooling At 100% load: 0 50 °C Derate linearly above 50°C by 2.5% per °C. At 50% load: 70 Storage Temperature -40 85 °C Relative Humidity Non-Condensing. 5 95 %RH Shock Peak acceleration. 20 GPK Vibration Random vibration, 10 Hz to 2 kHz, 3 axis. 6 GRMS 2 CPD SERIES - 250 WATT OVERALL SIZE: 5.07"H x 1.60"W x 6.40"D (128.7mm x 40.6mm x 162.5mm) WEIGHT: 1.75 lb (0.8 kg) 6.671" (169.4mm) 6.399" (162.5mm) 0.1" (2.54mm) 3U x 8HP 1.6" (40.6mm) Tolerances ± 0.012" (0.3mm) unless otherwise indicated. 3 0.26" (6.61mm) 3.74" (95.0mm) 0.507" (12.88mm) 3.937" (100.0mm) 5.067" (128.7mm) CPD SERIES - 250 WATT PIN ALLOCATION CHART PIN-LENGTH SIGNAL PIN-LENGTH SIGNAL PIN DESCRIPTION PIN DESCRIPTION TYPE (NOTE 1) NAME TYPE (NOTE 1) NAME 1-4 M V1 V1 OUTPUT 32 M NC NOT CONNECTED 5-12 M RTN V1 and V2 RETURN 33 M V2 SENSE V2 REMOTE SENSE 13-18 M V2 V2 OUTPUT 34 M S RTN SENSE RETURN 19 M RTN V3 RETURN 35 M V1SHARE V1 CURRENT SHARE 20 M V3 V3 OUTPUT 36 M V3SENSE V3 REMOTE SENSE 21 M V4 V4 OUTPUT 37 M NC NOT CONNECTED 22 M RTN SIGNAL RETURN 38 M DEG# DEGRADE SIGNAL 23 M RESERVED RESERVED 39 M INH# INHIBIT 24 M RTN V4 RETURN 40 M NC NOT CONNECTED 25 M NC NOT CONNECTED 41 M V2SHARE V2 CURRENT SHARE 26 M RESERVED RESERVED 42 M FAL# FAIL SIGNAL 27 S EN# ENABLE 43 M NC NOT CONNECTED 28 M NC NOT CONNECTED 44 M V3SHARE V3 CURRENT SHARE 29 M NC NOT CONNECTED 45 L CGND CHASSIS GROUND 30 M V1SENSE V1 REMOTE SENSE 46 M +DCIN + DC INPUT 31 M NC NOT CONNECTED 47 M -DCIN - DC INPUT NOTE 1) L = Long-Length Pins, M = Medium-Length Pins, S= Short-Length Pins NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 4

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the NHS-24-100 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

NP12 DC power conditioner, USED WITH 2-WAY RADIOS AND DATA TRANSCEI, MOBILE COMMUNICATIONS

NS1220STARTGUARD voltage drop prevention, USED WITH SENSITIVE ELECTRONICS, PREVENT VOLTAGE