Elite.Parts chervon right Manufacturers chervon right M chervon right MITSUBISHI chervon right FX0-14MT-DSS
About product Specifications Datasheet FAQ

MITSUBISHI FX0-14MT-DSS

Image of MITSUBISHI FX0-14MT-DSS

Description

MITSUBISHI FX0-14MT-DSS PLC DC BASE UNIT 8 DC IN AND 6 DC OUT power supply

Part Number

FX0-14MT-DSS

Price

Request Quote

Manufacturer

MITSUBISHI

Lead Time

Request Quote

Category

COMPONENTS

Specifications

applied instrument

10-100 microsec

Basic instructions

1.6 to 3.6 microsec

Counters

16

data register

32 (2 stored in EEPROM)

Internal Relays

512 (16 stored in EEPROM)

Program size

800 steps

Supply Voltage

115-230 VAC, 24 VDC

timers

56

Datasheet

pdf file

mitsubishi-FXO-30MR-ES-UL-datasheet1-487880225.pdf

544 KiB

Extracted Text

Looking for more information? Visit us on the web at http://www.artisan-scientific.com for more information: • Price Quotations • Drivers· Technical Specifications. Manuals and Documentation Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment • Tens of Thousands of In-Stock Items • Fast Shipping and DelIve1y • Equipment Demos • Leasing / Monthly Rentals • Hundreds of Manufacturers Supported • Consignment Service Center Repairs InstraView Remote Inspection Experienced Engineers and Technicians on staff in our Remotely inspect equipment before purchasing with our State-of-the-art Full-Service In-House Service Center Facility Innovative InstraView-website at http://www.instraview.com We bUy used equipment! We also offer credit for Buy-Backs and Trade-Ins Sell your excess. underutilized. and idle used equipment. Contact one of our Customer Service Representatives todayl Talk to a live person: 88EM38-S0URCE fB88-887-68721 I Contact us by email: sales@artisan-scientific.com I Visit our website: http://www.artisan-scientific.com FX Series PLC MELSEC FX0 Inputs: 8/12/16 Outputs: 6/8/14 Output types: Relay/Transistor Supply voltage: 115~230 VAC, 24 VDC Internal relays: 512 (16 stored in EEPROM) Data registers: 32 (2 stored in EEPROM) Timers: 56 States: 64 (10 for initial state) Counters: 16 (2 stored in EEPROM) High speed counters: Max. 4. 32 bits U/D and A/B counting Max. frequency 5 kHz/2 kHz Operation processing time: Basic instruction: 1.6 to 3.6 microsec Applied instr:10-100 microsec Number of instructions: 20 sequence; 35 applied instr. 2 stepladder Program size: 800 steps (stored in EEPROM) Measures: 100 x 80 x 47 (FX0-14, relay outputs, 24 V DC) FX0-14MR- 24 VDC Input (Sink/Source) Relay 8 In / 6 Out ES/UL Output, 2A/point, 8A/4 points 120/240 VAC Power Supply 800 Step Program FX0-20MR- 12 In / 8 Memory ES/UL Out JY992D47501 FX0/FX0N H/W Man FX0-30MR- 16 In / 14 (Included) JY992D48301 Programming ES/UL Out Manual (Optional) Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com FX0-14MT- 24 VDC Input (Sink) Transistor Output 8 In / 6 Out E/UL (Sink) 0.5A/pt, 0.8A/4 pts 120/240 VAC Power Supply 800 Step Program Memory FX0-20MT- 12 In / 8 JY992D47501 FX0/FX0N H/W Manual E/UL Out (Included) JY992D48301 Programming FX0-30MT- 16 In / 14 Manual (Optional) E/UL Out FX0-14MT-DSS 8 In / 6 Out 24 VDC Input (Sink/Source) Transistor Output (Source), 0.5A/pt, 0.8A/4pts, 12 In / 8 FX0-20MT-DSS 24VDC Pwr Supply 800 Step Program Out Memory JY992D47501 FX0/FX0N H/W Manual 16 In / 14 FX0-30MT-DSS (Included) JY992D48301 Programming Out Manual (Optional) FX0-14MT-D/E 8 In / 6 Out 24 VDC Input (Sink)Transistor Output (Sink) 0.5A/pt, 0.8A/4 pts 24 VDC Power 12 In / 8 FX0-20MT-D/E Supply 800 Step Program Memory Out JY992D47501 FX0/FX0N H/W Manual 16 In / 14 (Included) JY992D48301 Programming FX0-30MT-D/E Out Manual (Optional) MELSEC FX0S Inputs: 6/8/12/16 Outputs: 4/6/8/14 Output types: Relay Supply voltage: 115~230 VAC Internal relays: 512 (16 stored in EEPROM) Data registers: 32 (2 stored in EEPROM) Timers: 56 States: 64 (10 for initial state) Counters: 16 (2 stored in EEPROM) High speed counters: Max. 4. 32 bits U/D and A/B counting Max. frequency 7 kHz/2 kHz Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com Operation processing time: Basic instruction: 1.6 to 3.6 microsec Applied instr:10-100 microsec Number of instructions: 20 sequence; 35 applied instr. 2 stepladder Program size: 800 steps (stored in EEPROM) Measures: 60 x 90 x 75 FX0S-10MR- 24 VDC Input (Sink/Source), Relay 6 In / 4 Out ES/UL Output, 2.5A/point, 8A/4 points, 120- FX0S-14MR- 240 VAC Power 800 Step Program 8 In / 6 Out ES/UL Memory JY992D55301 FX0S H/W Manual FX0S-20MR- 12 In / 8 Out (Included) ES/UL JY992D48301 Programming Manual FX0S-30MR- 16 In / 14 (Optional) ES/UL Out FX0S-10MR- 6 In / 4 Out DS 24 VDC Input (Sink/Source), Relay FX0S-14MR- Output, 2.5A/point, 8A/4 points, 24 VDC 8 In / 6 Out DS Power 800 Step Program Memory JY992D55301 FX0S H/W Manual FX0S-20MR- 12 In / 8 Out (Included) JY992D48301 Programming DS Manual (Optional) FX0S-30MR- 16 In / 14 DS Out FX0S-10MT- 24 VDC Input (Sink/Source), Transistor 6 In / 4 Out DSS Output (Source), 0.5A/point, 0.8A/4 FX0S-14MT- points, 24 VDC Power 800 Step Program 8 In / 6 Out DSS Memory JY992D55301 FX0S H/W Manual FX0S-20MT- 12 In / 8 Out (Included) DSS JY992D48301 Programming Manual FX0S-30MT- 16 In / 14 (Optional) DSS Out Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com FX0S-16MR- 120 VAC Input, Relay Output, 10 In / 6 Out UA1/UL 2.5A/pt.,8A/4 pts. 120-240 VAC Power, 800 Step Program Memory JY992D55301 FX0S H/W Manual FX0S-24MR- 14 In / 10 (Included) JY992D48301 Programming UA1/UL Out Manual (Optional) MELSEC FX0N Inputs: 14/24/36 Outputs: 10/16/24 Output types: Relay/Transistor Supply voltage: 115~230 VAC; 24 VDC Internal relays: 512 (128 stored in EEPROM) Data registers: 256 (128 stored in EEPROM) Timers: 64 States: 128 Counters: 32 (16 stored in EEPROM) High speed counters: Max. 4. 32 bits U/D and A/B counting Max. frequency 5 kHz/2 kHz Operation processing time: Basic instruction: 1.6 to 3.6 microsec Applied instr:10-100 microsec Number of instructions: 20 sequence; 42 applied instr. 2 stepladder Program size: 2000 steps (stored in EEPROM) Measures: 130 x 90 x 87 (FX0-14, relay outputs, 24 V DC) FX0N Base Units Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com FX0N-24MR- 14 In / 10 24 VDC Input (Sink/Source), ES/UL Out Relay Output, 2A/point, 8A/4 points 120/240 VAC Power Supply 2,000 Step FX0N-40MR- 24 In / 16 Program Memory ES/UL Out JY992D47501 FX0/FX0N H/W Manual (Included) FX0N-60MR- 36 In / 24 JY992D48301 Programming Manual ES/UL Out (Optional) FX0N-24MR- 14 In / 10 24 VDC Input (Sink/Source) DS Out Relay Output, 2A/point, 8A/4 points 24 VDC Power Supply FX0N-40MR- 24 In / 16 2,000 Step Program Memory DS Out JY992D47501 FX0/FX0N Series H/W Manual (Incl) FX0N-60MR- 36 In / 24 JY992D48301 Programming Manual DS Out (Optional) FX0N-24MT- 14 In / 10 24 VDC Input (Sink/Source) DSS Out Transistor Output (Source), 0.5A/pt, 0.8A/4 pts FX0N-40MT- 24 In / 16 24 VDC Power Supply DSS Out 2,000 Step Program Memory JY992D47501 FX0/FX0N Series H/W FX0N-60MT- 36 In / 24 Manual (Incl) DSS Out JY992D48301 Programming Manual (Optional) 14 In / 10 24 VDC Input (Sink) Transistor Output FX0N-24MT Out (Sink) 0.5A/pt, 0.8A/4 pts., 120/240 VAC Power 24 In / 16 FX0N-40MT Supply Out 2,000 Step Program Memory JY992D47501 FX0/FX0N Series H/W 36 In / 24 Manual (Incl) FX0N-60MT Out JY992D48301 Programming Manual (Optional) 120 VAC Input FX0N-40MR- 24 In / 16 Relay Output, 2A/point, 8A/4 points UA1/UL Out 120/240 VAC Power Supply Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com 2,000 Step Program Memory JY992D47501 FX0/FX0N Series H/W Manual (Incl) JY992D48301 Programming Manual (Optional) FX0N Extension Units 24 VDC Input (Sink/Source), Relay FX0N-40ER- 24 In / 16 Output, 2A/pt ES/UL Out 8A/4 pt 120/240VAC Power Supply 24 VDC Input (Sink/Source), Relay 24 In / 16 FX0N-40ER-DS Output, 2A/pt Out 8A/4 pt 24 VDC Power Supply 24VDC Input (Sink/Source) Transistor FX0N-40ET- 24 In / 16 Output, DSS Out 0.5A/pt, 0.8A/4 pts 24 VDC Power Supply FX0N Extension Blocks FX0N-8EX- 8 In 24 VDC Input (Sink/Source) ES/UL FX0N-8EX- 8 In 120 VAC Input UA1/UL FX0N-8EYR- 8 Out Relay Output, 2A/point, 8A/4 points ES/UL FX0N-8EYT- Transistor Output (Source), 8 Out ESS/UL 0.5A/pt,0.8A/4pts FX0N-8EYT 8 Out Transistor Output (Sink), 0.5A/pt,0.8A/4pts FX0N-8EYT-H 8 Out Transistor Output (Sink),1A/pt, 2A/4pts FX0N-16EX- 16 In 24 VDC Input (Sink/Source) ES/UL FX0N-16EYR- 16 Out Relay Output, 2A/point, 8A/4 points ES/UL FX0N-16EYT- Transistor Output (Source), 16 Out ESS/UL 0.5A/pt,0.8A/4pts FX0N-8ER- 4 In / 4 24 VDC Input (Sink/Source), Relay ES/UL Out Output,2A/pt, Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com FX0N Special Function Blocks MELSECNET/MINI Interface FX0N-16NT JY992D48901 User's Guide (Included) RS-232 Adapter-(Add'l. port for communications with FX0N-232ADP external devices) JY992D51301 User's Guide (Included) Analog Input / Output Module, 2 In / 1 Out, 8 Bit FX0N-3A Resolution JY992D49001 User's Guide (Included) Battery (Req for cassette includes Real Time Clock Function FX0N-40B such as FX-EEPROM-4C,-8C or FX-RTC) JY992D48701 (Incl.) FX Multidrop Network Interface (allows conn to FX Multidrop FX0N-485ADP Network-RS485/422) JY992D53201User's Guide (Included) FX Multidrop Network PC Interface-Connect PC to FX Multidrop FX-485PC-IF Network - RS485/422)-JY992D53501 User's Manual (Included) Profibus DP slave module for FX0N FX0N-32NT-DP JY992D61401 User's Manual (Included) FX0N Base Unit to FX-1PG-E Special Function Block FX0N-5SBC-1 Cable Adapter-JY992D53701 User's Guide (Included) FX0N Base Unit to I/O Module Extension Cable - 25 FX0N-65EC inches JY992D45001 User's Guide Included Enhanced MELSEC FX Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com Inputs: 8/12/16/24/32/40/64 Outputs: 8/12/16/24/32/40/64 Output types: Relay/Transistor Supply voltage: 115~230 VAC; 24 VDC Internal relays:1 536 Data registers: 1000 File registers: 4000 Timers: 256 States: 1000 Counters: 256 High speed counters: Max. 6. 32 bits up(down counting Max. frequency 20 kHz/2 kHz Operation processing time: Basic instruction: 0.48 microsec Applied instr:10-100 microsec Number of instructions: 20 sequence; 96 applied instr. 2 stepladder Program size: 2000-8000 steps (RAM/EPROM/EEPROM) Measures: 150 x 140 x 95 (FX-16) Enhanced FX Base Units FX-16MR- 8 In / 8 Out ES/UL FX-24MR- 12 In / 12 24 VDC Input (Sink/Source) ES/UL Out Relay Output, 2A/point, 8A/4 points FX-32MR- 16 In / 16 120/240 VAC Power Supply ES/UL Out 2,000 step standard memory (Expandable to 8,000 steps) FX-48MR- 16 In / 16 ES/UL Out JY992D47401 FX Series Programmable FX-64MR- 32 In / 32 Controllers Hardware Manual (Included) ES/UL Out (JY992D48301 Programming Manual FX-80MR- 40 In / 40 Optional) ES/UL Out FX-128MR- 64 In / 64 ES/UL Out Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com FX-24MR- 12 In / 12 24 VDC Input (Sink) DS Out Relay Output, 2A/point, 8A/4 points 24 VDC Power Supply FX-48MR- 24 In / 24 2,000 step standard memory DS Out (Expandable to 8,000 steps) FX-64MR- 32 In / 32 JY992D47401 FX Series Programmable DS Out Controllers Hardware Manual FX-80MR- 40 In / 40 (JY992D48301 Programming Manual DS Out Optional) FX-24MR- 12 In / 12 120 VAC Input Relay Output, 2A/pt., UA1/UL Out 8A/4 pts. 120/240 VAC Power Supply FX-48MR- 24 In / 24 2,000 step standard memory UA1/UL Out (Expandable to 8,000 steps) JY992D47401 FX Series H/W Manual FX-64MR- 32 In / 32 (Included) UA1/UL Out JY992D48301 Programming Manual (Optional) FX-16MT- 8 In / 8 Out ESS/UL FX-24MT- 12 In / 12 24 VDC Input (Sink/Source) ESS/UL Out Transistor Output (Source), 0.5A/pt, 0.8A/4 pts FX-32MT- 16 In / 16 120/240 VAC Power Supply ESS/UL Out 2,000 step standard memory FX-48MT- 24 In / 24 (Expandable to 8,000 steps) ESS/UL Out FX-64MT- 32 In / 32 JY992D47401 FX Series H/W Manual ESS/UL Out (Included) (JY992D48301 Programming Manual FX-80MT- 40 In / 40 Optional) ESS/UL Out FX-128MT- 64 In / 64 ESS/UL Out FX2-16MT 8 In / 8 Out 24 VDC Input (Sink) Transistor Output (Sink), 0.5A/pt, 12 In / 12 FX2-24MT 0.8A/4 pts Out Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com 16 In / 16 120/240 VAC Power Supply FX2-32MT 2,000 step standard memory Out (Expandable to 8,000 steps) 24 In / 24 FX2-48MT Out (JY992D48301 Programming Manual 32 In / 32 Optional) FX2-64MT Out 40 In / 40 FX2-80MT Out 64 In / 64 FX2-128MT Out FX2-16MS 8 In / 8 Out 12 In / 12 24 VDC Input (Sink), Triac Output, FX2-24MS Out 0.3A/pt, 16 In / 16 0.8A/4 points 120/240 VAC Pwr. Supply, FX2-32MS Out 2,000 step standard memory (Expandable to 8,000 steps) 24 In / 24 FX2-48MS Out 32 In / 32 FX2-64MS (JY992D48301 Programming Manual Out Optional) 40 In / 40 FX2-80MS Out FX Extension Units FX-32ER- 16 In / 16 24 VDC Input (Sink/Source) ES/UL Out Relay Output, 2A/point, 8A/4 points 120/240 VAC Pwr Suply- FX-48ER- 24 In / 24 JY992D47401Manual Incl. ES/UL Out w/all FX Extension Units & FX Extension Blocks 24 VDC Input (Sink/Source), Relay Output 24 In / 24 FX-48ER-DS 2A/pt. Out 8A/4 points, 24 VDC Power Supply FX-48ER- 24 In / 24 120 VAC Input, Relay Output, 2A/point, UA1/UL Out 8A/4 points, 120/240 VAC Power Supply FX-48ET- 24 In / 24 24 VDC In (Sink/Source), Transistor Out ESS/UL Out (Source) Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com 0.5A/pt, 0.8A/4 pts, 120/240 VAC Power Supply 24 VDC In (Sink), Transistor Out (Sink) 24 In / 24 FX-48ET 0.5A/pt, 0.8A/4 pts, 120/240 VA C Power Out Supply FX Extension Blocks Transistor Output (Sink), FX-4EYT-H 4 Out High current output, 1A/point, 2A/4 points Triac Output, FX-4EYS-H 4 Out High Current Output, 1A/point, 2A/4 points FX-8EX- 8 In 24 VDC Input (Sink/Source) ES/UL FX-8EX- 8 In 120 VAC Input UA1/UL 5V DC TTL Input FX-8EX-L 8 In JY992D35401 User's Guide (Included) FX-8EYR- 8 Out Relay Output, 2A/point, 8A/4 points ES/UL Relay Output - Isolated, 2A/point, 8A/4 FX-8EYR-S 8 Out points JY992D35101 User's Guide (Included) FX-8EYT- Transistor Output (Source), 0.5A/point, 8 Out ESS/UL 0.8A/4 points Transistor Output (Sink), 0.5A/pt., 08A/4 FX-8EYT 8 Out pts. Transistor Output (Sink) FX-8EYT-H 8 Out High current output, 1A/point, 2A/4 points Triac Output FX-8EYS-H 8 Out High current output, 1A/point, 2A/4 points FX-8EYS- 8 Out Triac Output, 0.3 A/point, 0.8A4 points ES/UL FX-16EX- 16 In 24 VDC Input (Sink/Source) ES/UL 24 VDC Input (Sink) FX-16EX-C 16 In I/O connects using connector FX-16EX-V 16 In 24 VDC Input (Sink), Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com Vertical Terminal Strip (Same size as FX- 8Exx) FX-16EYR- 16 Out Relay Output, 2A/point, 8A/4 points ES/UL FX-16EYR- Relay Output, 2A/point, 8A/4 points 16 Out V Vertical terminal strip FX-16EYT- Transistor Output (Source) 16 Out ESS/UL 0.8A/4 points Transistor Output (Sink), 0.5A/point, FX-16EYT 16 Out 0.8A/4 points FX-16EYT- Transistor Output (Sink), 0.5A/pt, 0.8A/4 pts 16 Out C I/O connects using connector Transistor Output (Sink), 0.5A/pt, 0.8A/4 FX-16EYT- 16 Out pts, V Vertical terminal strip FX-16EYS- Triac Output 16 Out ES/UL 0.3 A/point, 0.8A/4 points FX-8ER- 4 In / 4 24 VDC Input (Sink/Source), ES/UL Out Relay Output, 2A/pt, 8A/4 pts FX Special Function Blocks Analog Input Module, 4 Channels (0-10V or 4- 20mA) FX-4AD 12 bit resolution, JY992D52601 User's Guide (Included) Thermocouple Input Module, 4 Channels (Individually FX-4AD-TC selectable type J or K), 12 bit resolution, JY992D55901 Usr. Guide Analog Output Module, 4 Channels (0-10V or 4- 20mA) FX-4DA 12 bit resolution, JY992D61001 User's Guide (Included) MELSECNET/MINI Interface, Fiber Optic link FX-16NP-S3 JY992D34601 User's Manual (Included) MELSECNET/MINI Interface, Wire link FX-16NT-S3 JY992D34601 User's Manual (Included) Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com FX Adapter Units RS-232 adapter. Provides additional serial port. FX-232ADP (Enhanced FX and FX2C only) JY992D48801 User's Guide (Incl.) Potentiometer input unit FX-8AV (8 potentiometers; values can be read into PLC program) Parallel Link Adapter - Fiber Optic. (Connects two FX or FX2C FX2-40AP PLCs. Allows transfer of 100 bits and 10 words between PLCs) Parallel Link Adapter - Twisted Pair. (Connects two FX or FX2C FX2-40AW PLCs. Allows transfer of 100 bits and 10 words between PLCs) FX Multidrop Network adapter (Enhanced FX and FX-485ADP FX2C only) JY992D53201 User's Guide (Included) FX Multidrop Network PC Interface (Required for FX-485PC- connecting IF a PC to the Multidrop Network) JY992D53501 User's Mnl. (incl.) FX Memory Memory Cassette, 8,000 Steps - RAM FX-RAM-8 (JY992D45801 User's Guide included with all memory cassettes) Memory Cassette, 8,000 Steps - RAM + Real Time Clock FX-RAM-8C (Year/leap year, month, date, day, hour, minute, and second) FX- Memory Cassette, 4,000 Steps - EEPROM EEPROM-4 (With Write Protect switch) Memory Cassette, 4,000 Steps - EEPROM + Real Time FX- Clock EEPROM-4C (Same clock specification as FX-RTC, with Write Protect) FX- Memory Cassette, 8,000 Steps - EEPROM Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com EEPROM-8 (With Write Protect switch) Memory Cassette, 8,000 Steps - EEPROM + Real Time FX- Clock EEPROM-8C rite (Same clock specification as FX-RTC, with W Protect) FX-EPROM- Memory Cassette, 8,000 Steps - EPROM 8 Real Time Clock Cassette FX-RTC (Year/leap year, month, date, day, hour, minute, and second) FX Programming Tools FX0/FX0N Prog. Loader (Transfer FX0S/FX0 programs. FX0- Can be 10LDR used with FX Mem. Cass.) JY992D38301 User's Guide (Incl.) Handheld Programmer, On-line. 2 x 16 LCD. Req. FX- 20P-CAB FX-10P-E (+ FX-20P-CADP for FX0/FX0S/FX0N) JY992D33401 (Incl.) Handheld Programmer, On/Off-line, 4 x 16 backlit LCD, FX-20P-E Program Storage. JY992D19101 Operation Manual (Included) FX-20P-E Power Adapter (For off-line programming FX-20P- and transfer to/from programming software) ADP-KIT JY992D32501 (Incl.) FX-20P- Write EEPROM/EPROM cassettes with FX-20P-E RWM JY992D25601 User's Guide (Included) FX-ROM- Adapter - To program EPROM via programming SOC-1 software Programming s/w for all FX Family PLCs, Single User MELMSW- License FX-1 JY992D48301 Prog. Mnl, MELSECMEDOC-MANUAL (Incl.) Programming s/w for all FX Family PLCs, 5 User License MELMSW- JY992D48301 Prog. Mnl, MELSECMEDOC-MANUAL FX-5 (Incl.) MELMSW- Programming s/w for all FX Family PLCs, 10 User Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com FX-10 License JY992D48301 Prog. Mnl, MELSECMEDOC-MANUAL (Incl.) PLCs, 25 User Programming s/w for all FX Family MELMSW- License FX-25 JY992D48301 Prog. Mnl, MELSECMEDOC-MANUAL (Incl.) Programming s/w for all FX Family PLCs, 50 User MELMSW- License FX-50 JY992D48301 Prog. Mnl, MELSECMEDOC-MANUAL (Incl.) Converter Cable - For use with programming s/w (9 Pin SC09 DSUB to 25 Pin DSUB and 25 Pin DSUB to 8 Pin Mini-DIN) FX-20P- Cable - 25 Pin DSUB to 8 Pin Mini-DIN CADP (Connects SC05-N or FX-20P-CAB to FX0, FX0S or FX0N) Cable - FX-10DU-E and Programmers to Enhanced FX or FX-20P- FX2C CAB Base Unit FX Miscellaneous Power Supply, 1A @ 24 VDC, 120/240 VAC Powered FX-10PSU JY992D37301 User's Guide (Included) Power Supply, 2A @ 24 VDC, 120/240 VAC Powered FX-20PSU JY992D37301 User's Guide (Included) Cable - 1.5 meter (5' 11") FX-150EC For Extension Unit. JY992D26501 User's Guide (Included) Cable - 3.0 meter (9' 10") FX-300EC For Extension Unit. JY992D26501 User's Guide (Included) Cable for Extension Block - .6 meter (2' 0") FX-60BC For Extension Block. JY992D26401 User's Guide (Included) Terminal Strip - 24 pin, For use on FX-32Mx, 32Ex, Y451C03201 64Mx, 128Mx Terminal Strip - 20 pin, For use on FX-16Mx, 24Mx, Y451C03202 64Mx, 128Mx Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com Terminal Strip - 38 pin, For use on FX-48Mx, 48Ex, Y451C03203 80Mx, 128Mx FX-RUN- Run/Stop Switch SW-E JY992D50101 User's Guide (Included) Input Simulation Switch for FX-24Mx FX-24SW-E JY992D24801 User's Guide (Included) Input Simulation Switch for FX-32Mx, 32Ex FX-32SW-E JY992D24801 User's Guide (Included) Input Simulation Switch for FX-48Mx, 48Ex FX-48SW-E JY992D24801 User's Guide (Included) Input Simulation Switch for FX-64Mx, 64Ex FX-64SW-E JY992D24801 User's Guide (Included) Input Simulation Switch for FX-80Mx, 80Ex FX-80SW-E JY992D24801 User's Guide (Included) FX Demo/Training Kit, Base unit with FX-32MT- ESS/UL, FX-DEMO FX-8EYR-ES/UL, simulation switches & displays. Inc. FX-20P-E. FX-INTRO- Introductory Guide To Programmable Controllers GUIDE FX- One Hundred And One Ways To Use A Programmable 101APPLIC Controller FX-ADVAN- FX Advanced Manual MANU F2-40BL Backup battery for Enhanced FX and FX2C PLCs Backup Capacitor (alternative to battery back-up for FX-40CAP Enhanced FX and FX2C) JY992D19401 User's Guide (Included) 2 Port Interface (Simultaneous communication FX-2PIF-001 with PLC from both MTA and MEDOC) JY992D44301 (Included) FX Operator Interfaces 2 line x 16 Backlit LCD, Disp. text & PLC data. Req. FX-20P-CAB FX-10DU-E (+ FX-20P-CADP for FX0,0S & 0N) JY992D54801 (Included) Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com Data Access Unit, Display PLC data FX-20DU-E JY992D54801 User's Manual (Included) FX2C Base Units FX2C- 64MT- 32 In / 32 Out 24 VDC Input (Sink/Source) ESS/UL Transistor Output (Source) FX2C- Connector I/O Termination 96MT- 48 In / 48 Out 120/240 VAC Power Supply ESS/UL 2,000 step standard memory (Expandable to 8,000 steps) FX2C- Use with optional Terminal Block 128MT- 64 In / 64 Out I/O ESS/UL JY992D47401 (Included), FX2C- JY992D48301 (Optional) 160MT- 80 In / 80 Out ESS/UL FX2C- 24 VDC Input (Sink) 32 In / 32 Out 64MT-E/UL Transistor Output (Sink) Other specs. as FX2C-xxMT- FX2C- ESS/UL 128MT- 64 In / 64 Out JY992D47401 (Included), E/UL JY992D48301 (Optional) FX2C-64MT 32 In / 32 Out 24 VDC Input (Sink) Transistor Output (Sink) FX2C-96MT 48 In / 48 Out Connector I/O Termination FX2C- 120/240 VAC Power Supply 64 In / 64 Out 128MT 2,000 step standard memory (Expandable to 8,000 steps) Use with optional Terminal Block FX2C- 80 In / 80 Out I/O 160MT JY992D48301 Programming Manual (Optional) FX2C Terminal Blocks Note: "/UL" type terminal blocks can only be used with "- ESS/UL" type base units Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com Passive Terminal Block (Use as inputs or FX-16E-TB/UL 16 In or 16 Out outputs) JY992D50401 User's Guide (Included) Passive Terminal Block (Use as inputs or FX-32E-TB/UL 32 In or 32 Out outputs) JY992D50401 User's Guide (Included) FX-16EX-A1- 120 VAC Input 16 Inputs TB/UL JY992D50401 User's Guide (Included) FX-16EYR-ES- Relay Output, 2A/point, 8A/4 points 16 Outputs TB/UL JY992D50401 User's Guide (Included) Transistor Output (Source), 0.5A/pt, 0.8A/4 FX-16EYT-ESS- 16 Outputs pts TB/UL JY992D50401 User's Guide (Included) FX-16EYT-ES- Transistor Output (Sink), 0.5A/pt, 0.8A/4 pts 16 Outputs TB/UL JY992D50401 User's Guide (Included) FX-16EYS-ES- Triac Output, 0.3A/point, 0.8A/4 points 16 Outputs TB/UL JY992D50401 User's Guide (Included) FX2C Terminal Blocks Note: These terminal blocks can only be used with "MT" and "MT- E/UL" base units Passive Terminal Block (Use as inputs or FX-16E-TB 16 In or 16 Out outputs) FX-16EX-A1-TB 16 Inputs 120 VAC Input FX-16EYR-TB 16 Outputs Relay Output, 2A/point, 8A/4 points FX-16EYT-TB 16 Outputs Transistor Output (Sink), 0.5A/pt, 0.8A/4 pts FX-16EYS-TB 16 Outputs Triac Output, 0.3A/point, 0.8A/4 points FX2C Cables FX2C Base Unit to Terminal Block Cable - 1.5 meter (4' FX-16E-150CAB-R 11") FX2C Base Unit to Terminal Block Cable - 3.0 meter (9' FX-16E-300CAB-R 10") FX2C Base Unit to Terminal Block Cable - 5.0 meter (16' FX-16E-500CAB-R 5") Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com FX2C Base Unit to A-Series (A6TBXY) FX-A32E-150CAB Terminal Block Cable - 1.5 meter (4' 11") FX2C Base Unit to A-Series (A6TBXY) FX-A32E-300CAB Terminal Block Cable - 3.0 meter (9' 10") FX2C Base Unit to A-Series (A6TBXY) FX-A32E-500CAB Terminal Block Cable - 5.0 meter (16' 5") Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com Looking for more information? Visit us on the web at http://www.artisan-scientific.com for more information: • Price Quotations • Drivers· Technical Specifications. Manuals and Documentation Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment • Tens of Thousands of In-Stock Items • Fast Shipping and DelIve1y • Equipment Demos • Leasing / Monthly Rentals • Hundreds of Manufacturers Supported • Consignment Service Center Repairs InstraView Remote Inspection Experienced Engineers and Technicians on staff in our Remotely inspect equipment before purchasing with our State-of-the-art Full-Service In-House Service Center Facility Innovative InstraView-website at http://www.instraview.com We bUy used equipment! We also offer credit for Buy-Backs and Trade-Ins Sell your excess. underutilized. and idle used equipment. Contact one of our Customer Service Representatives todayl Talk to a live person: 88EM38-S0URCE fB88-887-68721 I Contact us by email: sales@artisan-scientific.com I Visit our website: http://www.artisan-scientific.com

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the FX0-14MT-DSS have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Mitsubishi A1S-61PN - Power Supply Module

product

BASE UNIT

product

Mitsubishi A68DAV Output Module - 8 Channel Output Module (high resolution) 0 to ±10V O/P

product

Mitsubishi A6TBXY36 Terminal Block - TERMINAL BLOCK SINK 32POINT

product

Mitsubishi A7GT-BUS - Multi Drop Bus Connection Interface Module

product

Mitsubishi AD76S Motion Controller | 2-Axis