MEGGER 550005B
Specifications
Accuracy
+/- 0.1 percent
Exciting Current
0 - 1 Amp
Metering
Decade dials - 4
Output
8 Volts, 50/60 Hertz Line operated units supply 5 Amps mzx. for tests on specialty power transformers with high ratios & low secondary voltages
Power
Hand crank
Size (HxWxD)
7.5 x 14 x 12 inches; 189 x 353 x 302 millimeters
Turn Ratio
0.001 to 129.999
Weight
16 pounds (7.3 kilograms)
Features
- High Sensitivity—Measures Turn Ratios from 0.0000:1 to 129.999:1
- Identifies Incorrect Connections, Opens, Shorts, Internal Faults, Tap-Changer Defects
- Measures Excitation Current from 0 to 1A
- Reliable Hand-Crank Operation
- Three Separate Analog-Meter Displays
Datasheet
Extracted Text
® Single-phase, Hand-cranked TTR Transformer Turns Ratio Test Set ® Single-phase, Hand-cranked TTR Transformer Turns Ratio Test Set n Used for testing single phase power and distribution transformers n Design based on precision bridge measuring technique n Unmatched accuracy (±0.1%) in a portable design DESCRIPTION APPLICATIONS ® The Single-phase TTR Transformer Turns Ratio Test Set The single phase model is primarily used for testing single- measures the turns ratio and exciting current of windings phase power and distribution transformers, for low-ratio in power, potential and current transformers. Deviations readings up to 129.99:1, or up to 329.99:1 with an auxiliary in turns ratio readings indicate problems in one or both transformer. It can be used to test three-phase transformers windings or the magnetic core circuit. by connecting and testing each phase separately. The TTR test set aids in identifying: FEATURES AND BENEFITS n Shorted coils n Provides unmatched accuracy (±0.1%) in a portable de- sign. n Open circuits n Packaged in a rugged, compact case. n Incorrect connections n Measures highly sensitive turn ratios up to 129.99:1. An n Internal faults or tap-changer defects in step regulators as optional auxiliary transformer extends this ratio range to well as in transformers. 329.99:1. The single-phase, hand-cranked model measures highly sensitive turns ratios of up to 129.99:1 with accuracy of SPECIFICATIONS ±0.1%. An optional auxilary transformer extends the ratio range to 329.99:1. Output 8 V, 50/60 Hz The TTR set operates on the principle that the voltage ratio Metering of the transformer at no load is practically equal to the true Four decade dials turns ratio. Turns Ratio Range The major source of error in a transformer is a primary 0.001 to 129.999 impedance drop due to magnetizing current, which is kept to a minimum by excitation at a fraction of rated voltage. Exciting Current 0 to 1 A (divide by 5 switch for increased resolution) By employing a design that meets both of these conditions along with the use of a null balance system, the turns ratio Accuracy of a transformer can be determined accurately. ±0.1% When measuring the turns ratio of distribution and power Dimensions transformers, the accuracy is well within 0.1%. 7.5 H x 14 W x 12 D in. (189 H x 353 W x 302 D mm) Weight 16 lb (7.3 kg) ® Single-phase, Hand-cranked TTR Transformer Turns Ratio Test Set Calibration Reference Transformer OPTIONAL ACCESSORIES Calibration reference transformers are available for hand- Auxiliary Transformer crank TTRs. They provide a reference standard for periodic An auxiliary transformer extends the ratio range of single- calibration checks to document proof of calibration. phase models to 329.99:1. Turns ratio is 100:1 and 200:1, and is accurate to within ±0.1%. A Calibration Certificate of turn ratio accuracy traceable to the NIST is furnished with each calibration reference The auxiliary transformer includes all the necessary cables transformer, providing accuracies of ±0.05%. for connection to the TTR set and the transformer under test. Dimensions 13 L x 9.25 W x 7 H in. (330 L x 235 W x 178 H mm) Dimensions 8 H x 13 W x 10 D in. (203 H x 330 W x 254 D mm) Weight 19 lb (8.6 kg) Weight 13 lb (5.9 kg) ORDERING INFORMATION Item (Qty) Cat. No. Single-phase, Hand-cranked TTR 550005B Included Accessories Cable assembly 19494 With C-clamps for X (low-voltage) winding, 10 ft (3 m) [2] With spring clips for H (high-voltage) winding, 13 ft (4 m) [2] All cables are permanently connected to the test set. Instruction manual AVTM55JD Optional Accessories Auxiliary transformer 550030 Calibration reference transformer 550050 UK UNITED STATES OTHER TECHNICAL SALES OFFICES ISO STATEMENT Archcliffe Road, Dover 4271 Bronze Way Valley Forge USA, College Station Registered to ISO 9001:1994 Reg no. Q 09250 CT17 9EN England Dallas, TX 75237-1019 USA USA, Sydney AUSTRALIA, Täby Registered to ISO 14001 Reg no. EMS 61597 T (0) 1 304 502101 T 1 800 723 2861 SWEDEN, Ontario CANADA, Trappes F (0) 1 304 207342 T 1 214 333 3201 FRANCE, Oberursel GERMANY, Aargau SINGLEPH_TTR_DS_en_V13 F 1 214 331 7399 SWITZERLAND, Kingdom of BAHRAIN, www.megger.com Mumbai INDIA, Johannesburg SOUTH Megger is a registered trademark AFRICA, and Chonburi THAILAND
Frequently asked questions
What makes Elite.Parts unique?

What kind of warranty will the 550005B have?

Which carriers does Elite.Parts work with?

Will Elite.Parts sell to me even though I live outside the USA?

I have a preferred payment method. Will Elite.Parts accept it?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods