Elite.Parts Manufacturers M MARCONI 486800123
About product Datasheet FAQ

MARCONI 486800123

Description

DC/DC Converter Module 10Amps

Part Number

486800123

Price

Request Quote

Manufacturer

MARCONI

Lead Time

Request Quote

Category

PRODUCTS - 4

Datasheet

pdf file

486800123.pdf

332 KiB

Extracted Text

Marconi Communications Inc. Confidential 1. SPECIFICATION INPUT RATINGS (2) Wide band noise is typically 400 millivolts peak to peak over the frequency range of 10 Hz to 50 MHz. Does not exceed 500 millivolts. (3) Wide band noise is typically 55 millivolts rms over the frequency range of 10 Hz to 50 MHz. Does not exceed 100 millivolts rms. 1.2.3 Current (A) With one converter module installed, 10 Amperes, two converter modules installed, 20 Amperes, three converter modules installed, 30 Amperes. 1.3 INPUT RATINGS 1.3.1 Voltage: 48 volts DC positive ground, with operational range of 42 to 57 volts DC. 1.3.2 Filtering: The following measurement is valid for the ambient temperature range of -20°C to +65°C (-4°F to +149°F) (A) Voice band noise is less than 21 dBrn when measured at the input terminals with a noise meter using 600 ohm bridged input and C-message weighting. 1.3.3 SELV: This product requires a Safety Extra-Low Voltage (SELV) Input. A SELV input (based on the safety requirements for Information Technology Equipment Standards, such as UL1950, IEC 950) is a secondary circuit which is so designed and protected that under normal and single-fault conditions, the voltage between any two parts of the SELV circuit or circuits and for Class I equipment (provided with a protective earthing conductor from the building), between any one such part and the equipment protec- tive earthing terminal does not exceed a safe value (42.4 V peak or 60 Vdc under normal conditions). It is separated from the primary or mains supply by Double (insulation comprising both Basic and Supple- mentary insulation) or Reinforced insulation (a single insulation system which provides a degree of pro- tection against electric shock equivalent to Double insulation). PD588248400 PAGE 2 Marconi Communications Inc. Confidential 1. SPECIFICATION INPUT RATINGS 1.3.4 Typical Input Data- when equipped with one converter module: (A) 140 volts at the converter output terminals with the following line and load: DC Input Percent of Input Current Efficiency Voltage Full Load (Amperes) (%) 00.4 - 25 9.35 89.1 42 50 18.25 91.3 75 27.68 90.3 100 37.5 88.8 00.4 - 25 8.3 87.9 48 50 16.06 90.8 75 24.15 90.6 100 32.83 88.8 00.4 - 25 7.11 86.4 57 50 13.67 89.3 75 20.37 90.4 100 27.35 89.8 (B) Maximum input current does not exceed 41.5 amperes at 105% load with the input voltage at 42 volts and 145 volts at the converter output terminals. PD588248400 PAGE 3 Marconi Communications Inc. Confidential 1. SPECIFICATION INPUT RATINGS 1.3.5 Typical Input Data - when equipped with two converter modules with paralleled inputs: (A) 140 volts at the converter output terminals with the following line and load: DC Input Percent of Input Current Efficiency Voltage Full Load (Amperes) (%) 00.7 - 25 18.7 89.1 42 50 36.5 91.3 75 55.36 90.3 100 75.00 88.9 00.8 - 25 16.6 87.9 48 50 32.12 90.8 75 48.3 90.6 100 65.66 88.8 00.9 - 25 14.22 86.4 57 50 27.34 89.8 75 40.74 90.4 100 54.7 89.8 (B) Maximum input current does not exceed 83.0 amperes at 105% load with input voltage at 42 volts and 145 volts at the converter output terminals. PD588248400 PAGE 4 Marconi Communications Inc. Confidential 1. SPECIFICATION STANDARD FEATURES 1.3.6 Typical Input Data - when equipped with three converter modules with paralleled inputs: (A) 140 volts at the converter output terminals with the following line and load: DC Input Percent of Input Current Efficiency Voltage Full Load (Amperes) (%) 01.1 - 25 28.05 89.1 42 50 54.75 91.3 75 83.04 90.3 100 112.50 88.9 01.2 - 25 24.90 87.9 48 50 48.18 90.8 75 72.45 90.6 100 98.49 88.8 01.3 - 25 21.33 86.4 57 50 41.01 89.8 75 61.11 90.4 100 82.05 89.8 (B) Maximum input current does not exceed 124.5 amperes at 105% load with input voltage at 42 volts and 145 volts at the converter output terminals. 1.4 STANDARD FEATURES 1.4.1 Input Protection (A) A DC input circuit breaker present in each module opens the negative input lead. This input lead should be fused externally according to the recommendations of INSTALLER’S INFORMATION NOTE 4.1. (B) A low battery voltage sensing circuit in each module automatically inhibits converter operation if input voltage decreases below 40 volts. Converter operation resumes automatically before input voltage reaches 42 volts. 1.4.2 Output Protection PD588248400 PAGE 5 Marconi Communications Inc. Confidential 1. SPECIFICATION STANDARD FEATURES (A) Current Limiting: At nominal input voltage, output current is automatically limited to a preset adjustable level. The List 2 and List 3 current limit is factory set at 105% of full rated load. (B) Overvoltage Shutdown: The converter module will shut down if output voltage increases above a preset value. The List 2 overvoltage shutdown level is factory set at 150 volts DC, and has a label covering this adjustment. The List 3 overvoltage shutdown level is factory set at 140 volts DC. (C) Series Output Diode: A series output diode, enables paralleling with other converters. Load may not share proportionally between parallel connected units. 1.4.3 Alarms: Each converter module contains circuitry for extending alarms during a failure condition. Relay contacts of extended alarm circuits are rated for 1 ampere at 60 volts DC. Refer to Section 3. INSTALLER’S CONNECTIONS and Section 4. INSTALLER’S INFORMATION NOTES of this Power Data sheet for a description of the extended relay contacts. (A) Converter Fail Alarm: Form C relay contacts are provided for the connection of external alarms if one or more of the following failure conditions occur. These relay contacts are extended to connec- tor J4, and supply or remove positive battery (ground) during a failure condition. (1) Activation of fuse alarm circuit due to opening of output fuse. (2) Low voltage alarm due to DC output voltage decreasing below a preset limit. List 2 low volt- age alarm is factory set for 135.0 ±0.5 volts and has a label covering this adjustment. List 3 low voltage alarm is factory set for 120.0 ±0.5 volts and is adjustable over the range of 115.0 to 145.0 volts DC. (3) Input voltage decreases below the factory set limit of 39 volts, which automatically inhibits converter operation. (4) DC output failure for any reason, including an overvoltage shutdown, or loss of DC input. (5) Fan failure 1.4.4 Indicators: The following light emitting diodes (LEDs) provide local visual indication of the operating status of each converter module. These indicators are located on the front panel of the module unless otherwise specified. NOTE: Indicators will not illuminate unless battery is present at converter module input terminals and the input circuit breaker is on. (A) POWER ON: This green LED illuminates when DC input power is present and the input circuit breaker is l (on). (B) CONV FAIL ALARM: This red LED illuminates if a converter failure condition occurs. Failure con- ditions include opening of output fuse, low voltage alarm, converter output failure, low battery inhibit, and fan failure. (C) FAN FAIL ALARM: This red LED illuminates and the converter fail alarm is activated if the fan fails. 1.4.5 Meter Test Points: OUTPUT VOLTAGE test jacks, located on each converter module front panel, are provided as a convenient method for connecting an external high impedance DC voltmeter. PD588248400 PAGE 6 Marconi Communications Inc. Confidential 1. SPECIFICATION ENVIRONMENTAL RATINGS 1.4.6 Mounting: The equipment cabinet is designed for mounting in a 23 inch relay rack with 1 inch or 1 - 3/4 inch multiple mounting holes. Refer to ENVIRONMENTAL RATINGS in this Power Data sheet for fur- ther mounting location considerations. 1.4.7 Cooling: Forced convection 1.5 ENVIRONMENTAL RATINGS 1.5.1 Operating Temperature Range: -40°C to +65°C (-40°F to +149°F) 1.5.2 Storage Temperature Range: -40°C to +65°C (-40°F to +149°F). 1.5.3 Humidity: This DC-DC converter system is capable of operating in an ambient relative humidity range of 0% to 95%, noncondensing. 1.5.4 Altitude: The maximum ambient operating temperature should be derated by 10°C at an elevation of 10,000 feet above sea level. For elevations between 3,000 feet and 10,000 feet, derate the maximum operating ambient temperature linearly. 1.5.5 Heat Dissipation (Typical): Output adjusted to 140 volts DC and 48 volts input. Load conditions are: No load, half load, and full load. Number of No Load Half Load Full Load Modules (Btu/Hr) (Btu/Hr) (Btu/Hr) 1 66 242 600 2 131 485 1201 3 197 727 1802 1.5.6 Ventilation Requirements: The converter cabinet should be mounted so that ventilating openings are not blocked and temperature of the air entering the cabinet does not exceed +65°C (+122°F). 1.5.7 Audible Noise: With all three converters and fans operating, the audible noise at any point one meter from any vertical surface of the power shelf does not exceed 65 dBA when measured with a Sound Level Meter conforming to ANSI S1.4. 1.5.8 EMI/RFI Suppression: This unit conforms to the radiated noise requirements of FCC rules Part 15, Subpart B, for Class A computing devices. Additionally, conducted EMI on the DC input and output leads conforms to the requirements of Bellcore PUB 1089. 1.5.9 Safety Compliance: (A) This unit meets the requirements of UL 1950, Standard for Information Technology Equipment, and is UL Listed as a power supply for use in Telephone, Electronic Data Processing or Information Pro- cessing Equipment. PD588248400 PAGE 7 Marconi Communications Inc. Confidential 1. SPECIFICATION ACCESSORIES 1.5.10 European Compliance: This product conforms to the EU EMC Directive 89/336/EEC and harmonized standards EN55022 Class A and EN50082-1. 1.6 ACCESSORIES 1.6.1 Bus bar shorting adapter: This accessory provides two shorting adapters to convert the three separate inputs into one paralleled input. Specify one (1) of Part No. 418140800. 1.7 RELATED DOCUMENTATION 1.7.1 Schematic Diagram: SD588248400 1.7.2 Wiring Diagram: T588248400 1.7.3 Instructions: Section 5788 PD588248400 PAGE 8 Marconi Communications Inc. Confidential 2. DIMENSIONS 0.875 0.875 2.250 0.875 0.875 0.531 TOP VIEW MOUNTING ANGLE DETAIL SEE MOUNTING ANGLE DETAIL 0.875 DIA 1.375 DIA 6.890 2.906 1.078 20.890 4.578 22.328 10.328 23.140 11.531 R. SIDE VIEW FRONT VIEW 1.750 DIA 1.093 DIA NOTES: 1. ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE SPECIFIED. 2.000 2. WEIGHT IN LBS. (CABINET) NET: 20.0 SHIPPING: 25.0 3. WEIGHT IN LBS. (ONE MODULE) 2.718 NET: 11.0 SHIPPING: 13.0 4. FINISH: OFF WHITE. 5. 4.578 INDICATES VENTILATING GRILL 10.328 11.531 L. SIDE VIEW PD588248400 PAGE 9 Marconi Communications Inc. Confidential 3. INSTALLER’S CONNECTIONS TB2 TB1 DC OUTPUT DC INPUT CONNECTOR CABINET REAR VIEW SHOWING CONNECTOR LOCATION Θ FRAME GROUND TERMINAL STUD PROVIDED FOR INSTALLATION NOTE 4.5 OF CUSTOMER FURNISHED LUG. SEE AND 4.14 NOTE 4.4 FOR RECOMMENDED LUG SIZE NOTE 4.11 NOTE 4.11 3 2 1 NOTE 4.11 NOTE 4.12 6 5 4 NOTE 4.12 NOTE 4.13 9 8 7 NOTE 4.13 1/4" STUD (1) NOTE 4.13 NOTE 4.12 † J4 NOTES 4.4 & 4.8, AND 4.15 ALARM AND CONTROL Θ PD588248400 PAGE 10 Marconi Communications Inc. Confidential 3. INSTALLER’S CONNECTIONS ACCESSORY BUS BAR SHORTING ADAPTERS NOTES 4.16 AND 4.19 FURNISHED BUS BAR ADAPTERS NOTES 4.17 AND 4.18 TB2 TB1 DC OUTPUT DC INPUT PD588248400 PAGE 11 Marconi Communications Inc. Confidential 4. INSTALLER’S INFORMATION NOTES 4.1 DC Input: The tables below list the recommended wire sizes for single module wiring. For wire sizing informa- tion on paralleling inputs and/or outputs, refer to the crimp and compression lug tables located later in this Power Data Sheet. 4.2 DC INPUT (Wiring for One Module) TB1 (NOTE 4.6) Recm Loop Recm Recm Wire Size Length (Ft) Capacity Fusing Torque (Note 4.10) (Note 4.9) 45 20 8 Ga. 8 Ga. 46 Amperes Inch Pounds Max 4.3 DC OUTPUT (Wiring for One Module) TB2 (NOTE 4.7) Recm Loop Recm Wire Size Length (Ft) Capacity Torque (Note 4.10) (Note 4.9) 14 Ga. 30 20 Inch 12 Ga. 48 8 Ga. Max Pounds 10 Ga. 76 4.4 FRAME GROUND TB3 Terminal Recm Recm Wire Size Torque Capacity Type (Note 4.10) 1/4 x 20 84 Inch --- 6 Ga. Max Stud Pounds PD588248400 PAGE 12 17 Marconi Communications Inc. Confidential 4. INSTALLER’S INFORMATION NOTES 4.5 ALARM (J4) Terminal Recm Loop Length Wire Size (Ft.) Capacity Type (Note 4.10) 0-200 22 Ga. 18 Ga. Locking Max. Plug over 200 18-20 Ga. 4.6 DC Input: Terminal Block (TB1) is provided for installation of customer furnished DC input lugs. The tables below list the recommended crimp or screw type pressure lugs for the various recommended wire sizes. The tables below are for use only when all three DC inputs are in parallel using the optional bus bar shorting adap- tors. Recommended torque for lug mounting hardware is 84 inch pounds. DC INPUT (TB1) SCREW TYPE COMPRESSION LUG (Three Modules connected in parallel) Recommended Lug Recm Loop Wire Size Length (Ft.) Capacity Recm (Note 4.10) (Note 4.9) Vendor(s) Part No. Torque 50 8 Ga. To 2 Ga. 39 LORAIN 245632400 Inch Pounds 2 Ga. Max DC INPUT - CRIMP LUG (TB1) (Three Modules connected in parallel) (Recm. Fusing 150 Amperes) *Crimp Tool Required Recommended T & B Model TBM12 Recm Lug OR Wire Loop Wire TBM15 Hydraulic Heads Size Length (Ft.) Stranding (Note (Note 4.9) Class Die Part Color Die Cat. 4.10) Vendor(s) Index/ No. Key Number Code No. T & B 54207 B Brown 33 15528 Burndy YA2CL-2TC14 2 Ga. 39 T & B N/A I Pink 42 15508 Burndy YA25L-2TC14 * The lugs should be crimped to the specifications given in the manufacturer’s instructions furnished with the crimp tool or lug. PD588248400 PAGE 13 Marconi Communications Inc. Confidential 4. INSTALLER’S INFORMATION NOTES 4.7 DC Output: Terminal Block (TB2) is provided for installation of customer furnished DC output lugs. The tables below list the recommended crimp or screw type pressure lugs for the various recommended wire sizes. These tables are for use when all three DC Outputs are in parallel using the furnished bus bar shorting adapters. Rec- ommended torque for lug mounting hardware is 84 inch pounds. DC OUTPUT - SCREW TYPE COMPRESSION LUG (Three Modules connected in parallel) Recommended Lug Recm Loop Wire Size Length (Ft.) Capacity Recm (Note 4.10) (Note 4.9) Vendor(s) Part No. Torque 8 Ga. 42 40 in lbs (8 Ga.) 8 Ga. to LORAIN 245632400 2 Ga. 6 Ga. 66 45 in lbs (6 Ga.) DC OUTPUT - CRIMP LUG (Three Modules connected in parallel) *Crimp Tool Required Recommended T & B Model TBM12 Recm Lug OR Wire Loop Wire TBM15 Hydraulic Heads Size Length (Ft.) Stranding (Note (Note 4.9) Class Die Part Color Die Cat. 4.10) Vendor(s) Index/ No. Key Number Code No. 1 1 1 B Burndy YAV10-R3 BOX - - - 10 Ga. 25 T & B 54850BE I Red 21 15520 Burndy YA27L-2TC38 T & B 54850BE B Red 21 15520 Burndy YA27L-2TC38 8 Ga. 42 T & B 54205 I Blue 24 15522 Burndy YA6CL-2TC14 T & B 54205 B Blue 24 15522 Burndy YA6CL-2TC14 6 Ga. 66 T & B 54206 I Grey 29 15527 Burndy YA4CL-2TC14 * The lugs should be crimped to the specifications given in the manufacturer’s instructions furnished with the crimp tool or lug. PD588248400 PAGE 14 17 Marconi Communications Inc. Confidential 4. INSTALLER’S INFORMATION NOTES 1 - Use T & B Model WT-1300 Shure Stake Hand Crimp Tool 4.8 Frame Ground: Threaded studs are provided for installation of a customer furnished frame ground lug. The tables below list the recommended screw type compression lugs and crimp lugs for the recommended wire size. Recommended torque for lug mounting hardware is 84 inch pounds. FRAME GROUND - SCREW TYPE COMPRESSION LUG (TB3) Recommended Lug Recm Wire Size Capacity Recm (Note 4.10) Vendor(s) Part No. Torque 45 Inch 6 Ga. LORAIN 245612600 2 to 8 Ga. Pounds FRAME GROUND - CRIMP LUG (TB3) 1 Recommended Crimp Tool Required Recm Lug Wire Wire Size Stranding Die (Note Class Part Color Die Cat. Vendor(s) Index/ 4.10) No. Key Number Code No. T & B 54105 B Blue 24 15522 Burndy YA6C-L-BOX 6Ga. T & B 54106 I Grey 29 15527 Burndy YA4C-L-BOX 1 The lugs should be crimped to the specifications given in the manufacturer’s instructions furnished with the crimp tool or lug. 4.9 The DC input/output wire sizes listed are sufficient to restrict voltage drop to 1.0 volt or less at rated full load out- put current for the loop lengths shown. Loop length is the sum of the lengths of the positive and negative leads. If a lead larger than specified is required due to loop length/voltage drop requirements, the installer should splice the larger lead to the wire connected to the equipment terminals. 4.10 Wire sizes based on recommendations of the National Electrical Code Table 310-16 for copper wire at 90°C con- ductor temperature, operating in ambient of 30°C. For operation in ambient higher than 30°C, apply derating factors listed in Table 310-16 of the National Electrical Code. 4.11 During normal operation of Converter Module 1, positive battery (ground) is provided at terminal 1 of J4, and positive battery (ground) is removed from terminal 3 of J4. If Converter Module 1 fails, positive battery (ground) is removed from terminal 1 of J4, and positive battery (ground) is provided at terminal 3 of J4. PD588248400 PAGE 15 Marconi Communications Inc. Confidential 4. INSTALLER’S INFORMATION NOTES 4.12 During normal operation of Converter Module 2, positive battery (ground) is provided at terminal 4 of J4, and positive battery (ground) is removed from terminal 6 of J4. If Converter Module 2 fails, positive battery (ground) is removed from terminal 4 of J4, and positive battery (ground) is provided at terminal 6 of J4. 4.13 During normal operation of Converter Module 3, positive battery (ground) is provided at terminal 7 of J4, and positive battery (ground) is removed from terminal 9 of J4. If Converter Module 3 fails, positive battery (ground) is removed from terminal 7 of J4, and positive battery (ground) is provided at terminal 9 of J4. 4.14 If extended open and closed loop alarm circuits are desired (instead of positive battery), disconnect, sleeve, and tie back the brown wire connected to J4, terminal 2 (module one); the white wire connected to J4, terminal 5 (module two) and the yellow wire connected to J4, terminal 8 (module three). Positive battery is no longer pro- vided at terminals 2 and 5 of J4. Extended form C alarm relay contacts of Converter Modules 1, 2 and 3 are now available at terminals of J4 as shown in the following table. Contact Status During Contact Status During Normal Converter Converter Failure Converter Operation (Relay Condition (Relay Designation Energized) Released) Open Closed Open Closed TB4-2 to TB4-1 to TB4-1 to TB4-2 to Module 1 TB4-3 TB4-2 TB4-2 TB4-3 TB4-5 to TB4-4 to TB4-4 to TB4-5 to Module 2 TB4-6 TB4-5 TB4-5 TB4-6 TB4-8 to TB4-7 to TB4-7 to TB4-8 to Module 3 TB4-9 TB4-8 TB4-8 TB4-9 4.15 If grounding of the converter chassis is required, connect a 6 Ga. wire from the FRAME GROUND connector to earth ground. Equipment grounding conductor size is based on recommendation of National Electrical Code Table 250-122 for copper wire. If aluminum or copper clad aluminum grounding conductor is used, refer to Table 250-122 for increased conductor size. 4.16 Converter cabinet is shipped wired for independent converter module DC inputs. For paralleled inputs connect one accessory shorting adapter between positive (+) inputs of Converter Module 1, Converter Module 2 and Converter Module 3. Connect the other accessory shorting adapter between negative (-) inputs of Module 1, Module 2 and Converter Module 3. Recommended torque is 20 inch pounds. 4.17 Converter cabinet is shipped wired for paralleled converter module DC outputs. For independent outputs, remove the furnished shorting adapter between positive (+) outputs of Converter Module 1, Converter Module 2 and Converter Module 3. Remove the other furnished shorting adapter between negative (-) outputs of Con- verter Module 1, Converter Module 2, and Converter Module 3. 4.18 Connect either the positive or negative output to the system grounded conductor. This connection must be made. The output cannot be left floating. PD588248400 PAGE 16 17 Marconi Communications Inc. Confidential 4. INSTALLER’S INFORMATION NOTES 4.19 SELV: This product requires a Safety Extra-Low Voltage (SELV) Input. A SELV input (based on the safety requirements for Information Technology Equipment Standards, such as UL1950, IEC 950) is a secondary circuit which is so designed and protected that under normal and single-fault conditions, the voltage between any two parts of the SELV circuit or circuits and for Class I equipment (provided with a protective earthing conductor from the building), between any one such part and the equipment protective earthing terminal does not exceed a safe value (42.4 V peak or 60 Vdc under normal conditions). It is separated from the primary or mains supply by Dou- ble (insulation comprising both Basic and Supplementary insulation) or Reinforced insulation (a single insulation system which provides a degree of protection against electric shock equivalent to Double insulation). 4.20 θ - indicates leads furnished and connected by the installer. 4.21 † - indicates mating connector to be furnished by the installer. Mating connector Part No. - Amp 172169-1 (P4) Mating Contact Part. No. - Amp 170362-3 Hand Crimp Tool Required - Amp 90711-1 PD588248400 PAGE 17 Marconi Communications Inc. Confidential

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 486800123 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

SA-400 Secure Hard Drive

SA-400: Security Appliance Chassis with dual power

SA-400 single hot-swappable spare power supply

product

Marconi 42GESBAASLE22JAZ7 Enclosures - 200 Amp, 120/240 AC, 1 Phase, 42 KAIC @ 240 VAC; Distribution...

product

Marconi 486529901 Rectifiers - 48V/50 AMP Rectifier for Vorte

product

MARCONI 486531001 48V/200 AMP 480AC INPUT RECTIF