Elite.Parts chervon right Manufacturers chervon right M chervon right MAGNECRAFT chervon right W222ACPFX-16
About product Specifications Datasheet FAQ

MAGNECRAFT W222ACPFX-16

Image of MAGNECRAFT W222ACPFX-16

Description

Magnecraft W222ACPFX-16 Relay - Repeat Cycle; 10 A (AC) @ 240 VAC, 10 A (DC) @ 28 VDC; ; 120 VAC; DPDT;

Part Number

W222ACPFX-16

Price

Request Quote

Manufacturer

MAGNECRAFT

Lead Time

Request Quote

Category

PRODUCTS - W

Specifications

Base Type

Octal

Coil VA Rating

2.5

Coil Volts

120VAC

Contact Amp Rating (Resistive)

10

Contact Form

DPDT

Contact Material

Silver Alloy

Function

Repeat Cycle

HP @ 120V

1/3

HP @ 240V

1/2

Hz

50/60

Item

Time Delay Relay

Max. Time Setting

5 min.

Min. Time Setting

3 sec.

Number of Contacts

2

Pins

8

Socket

6CVD6, 6CVD9

Standards

UL, CE, CSA

Type

Plug-In

Datasheet

pdf file

Magnecraft-W222ACPFX-16-ds1-321523910.pdf

1638 KiB

Extracted Text

Your Contact for Relays SECTION 4 TIME DELAY RELAYS 5 TO 13 AMPERES TIME DELAY RELAYS TDRPRO 67 211 RELAY SERIES L.E.D. STATUS LAMP L W H L W H L W H 1.7.5 x 2.37 x 3.5 1.87 x 1.87 x 2.86 1.37 x 0.734 x 1.18 8 OR 11 PIN OCTAL PLUG-IN 8 OR11 PIN OCTAL PLUG-IN MINIATURE PLUG-IN ON DELAY, OFF DELAY, INTERVAL AND ON DELAY, REPEAT, INTERVAL, ON DELAY ONE SHOT MODES AVAILABLE OFF DELAY & ONE SHOT REPEATABILITY ± 2% REPEATABILITY ±0.1% UNIVERSAL POWER SUPPLY FEATURES RECESSED SCREW ADJUSTMENT FIELD ADJUSTABLE BY KNOB, OR REPEATABILITY ±0.1% FIXED TIME AVAILABLE WITHOUT 4 POLE STYLES AVAILABLE KNOB FIELD ADJUSTABLE BY THUMB WHEELS PRINTED CIRCUIT TERMINALS OTHER TIMING RANGES & INPUT AVAILABLE VOLTAGES AVAILABLE PANEL MOUNTABLE OTHER TIMING RANGES & INPUT VOLTAGES AVAILABLE CONTACT DATA CONTACT CONFIGURATION: DPDT SPDT, DPDT DPDT CONTACT MATERIAL: SILVER CADMIUM OXIDE, SILVER CADMIUM OXIDE SILVER GOLD OVERLAY, GOLD FLASHED CONTACT RESISTANCE: 50 MILLIOHMS MAX. INITIAL 50 MILLIOHMS MAX. INITIAL 50 MILLIOHMS MAX. INITIAL MAX. CONTACT RATING: 10 AMPS @ 120 / 240 VAC, 30 VDC 12 AMPS @ 120 / 240 VAC, 30 VDC 5 AMPS @ 120 VAC, 28 VDC 1/3 HP@ 240 VAC RESISTIVE. 1/2 HP @ 120 VAC 1/3 HP@120 VAC 1/2 HP @ 240 VAC NEMA B300 PILOT DUTY COIL DATA STANDARD VOLTAGE 120 VAC 24 TO 240 VAC 120 VAC AC: 24 VDC 24 TO 240 VDC 12 & 24 VDC DC: 85 % TO +110 % (AC) 85 % TO +110 % (AC), INPUT VOLTAGE RANGE: 80 % TO +110 % (DC) 80 % TO +110 % (DC) OF NOMINAL OF NOMINAL REVERSE POLARITY YES - DC NON POLARITY SENSITIVE YES - DC PROTECTION: GENERAL DATA AMBIENT TEMPERATURE OPERATING: - 30˚C TO +55˚C - 10˚C TO +55˚C - 30˚C TO +55˚C STORAGE: - 55˚C TO +85˚C - 40˚C TO +85˚C - 50˚C TO +85˚C STANDARD TIMING RANGE: 0.1 SECOND TO 120 MINUTES 0.1 SECOND TO 9,990 HOURS 0.1 SECOND TO 450 SECONDS DIELECTRIC STRENGTH: 1500 V RMS 1500 V rms 1250 V rms LIFE EXPECTANCY (MIN.) ELECTRICAL: 200,000 OPERATIONS 200,000 OPERATIONS 50,000 OPERATIONS MECHANICAL: 10,000,000 OPERATIONS 10,000,000 OPERATIONS 10,000,000 OPERATIONS LISTED AGENCY APPROVALS 367G C US C US UL Recognized UL Recognized UL Recognized UL Listed File No. E43641 File No. E43641 File No. File No. E43641 PAGE NUMBER PAGE 7 - 8 PAGE 9 - 10 PAGE 11 CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS 4...1 TIME DELAY RELAYS 388 EXTERNAL 388 TRUE 388 KNOB 222 ADJUSTMENT OFF DELAY ADJUSTMENT L W H L W H L W H L W H 1.75 x 2.37 x 3.5 1.40 x 1.53 x 1.90 1.53 x 1.40 x 3.52 1.53 x 1.40 x 3.52 8 PIN OCTAL PLUG-IN SQUARE BASE PLUG-IN SQUARE BASE PLUG-IN SQUARE BASE PLUG-IN OR FLANGE MOUNT REPEAT CYCLE TIMER ON DELAY, OFF DELAY TRUE OFF DELAY ON DELAY, OFF DELAY ON AND OFF TIMES REPEATABILITY ±0.1% REPEATABILITY ±3% INDEPENDENTLY ADJUSTABLE REPEATABILITY ±3% FIELD ADJUSTABLE TIMING FIELD ADJUSTABLE TIMING REPEATABILITY ±0.1% FIELD ADJUSTABLE TIMING USING KNOB USING KNOB USING EXTERNAL RESISTOR FIELD ADJUSTABLE TIMING POWER TO INPUT NOT USING KNOBS REQUIRED DURING TIMING CYCLE OTHER TIMING RANGES & INPUT VOLTAGES AVAILABLE DPDT DPDT DPDT DPDT SILVER CADMIUM OXIDE, SILVER CADMIUM OXIDE, SILVER CADMIUM OXIDE, SILVER CADMIUM OXIDE, 50 MILLIOHMS MAX. INITIAL 50 MILLIOHMS MAX. INITIAL 50 MILLIOHMS MAX. INITIAL 50 MILLIOHMS MAX. INITIAL 10 AMPS @ 120 / 240VAC, 30 VDC 12 AMPS @ 120 VAC, 28 VDC 12 AMPS @ 120 VAC, 28 VDC 12 AMPS @ 120 VAC, 28 VDC 1/3 HP @ 120 VAC, 1/3 HP @ 120 VAC, 1/3 HP @ 120 VAC, 1/3 HP @ 120 VAC, 1/2 HP @ 240 VAC, 1/2 HP @ 240 VAC, 1/2 HP @ 240 VAC, 1/2 HP @ 240 VAC, NEMA B300 PILOT DUTY NEMA B300 PILOT DUTY NEMA B300 PILOT DUTY NEMA B300 PILOT DUTY 120 VAC 120 VAC 120 VAC 120 VAC 24 VDC 24 VDC 24 VDC 85 % TO +110% (AC), 85 % TO +110 % (AC) 85 % TO +110 % (AC) 85 % TO +110 % (AC) 80 % TO +110% (DC) 80 % TO +110 % (DC) 80 % TO +110 % (DC) 80 % TO +110 % (DC) OF NOMINAL OF NOMINAL OF NOMINAL OF NOMINAL YES - DC YES - DC YES - DC YES - DC - 30˚C TO +55˚C - 30˚C TO +55˚C - 30˚C TO +55˚C - 30˚C TO +55˚C - 55˚C TO +85˚C - 55˚C TO +85˚C - 55˚C TO +85˚C - 55˚C TO +85˚C 0.1 SECOND TO 30 MINUTES 0.1 SECOND TO 120 SECONDS 0.1 SECOND TO 180 SECONDS 0.1 SECOND TO 200 SECONDS 1500 V rms 1500 V rms 2000 V rms 2000 V rms 200,000 OPERATIONS 100,000 OPERATIONS 100,000 OPERATIONS 100,000 OPERATIONS 10,000,000 OPERATIONS 5,000,000 OPERATIONS 5,000,000 OPERATIONS 5,000,000 OPERATIONS C US UL Recognized UL Recognized UL Recognized UL Recognized File No. E52197 File No. E52197 File No. E52197 File No. E52197 PAGE 12 PAGE 13 - 14 PAGE 15 - 16 PAGE 17 4...2 CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS TIME DELAY RELAYS 235 286 & 287 326 & 327 CURRENT SENSOR RELAY SERIES L W H L W H L W H 1.37 X 1.37 X 3.62 2.37 x 1.75 x 3.52 1.50 x 1.37 x 3.52 SQUARE BASE PLUG-IN SQUARE BASE PLUG-IN 8 or 11 PIN OCTAL PLUG-IN 1.5 TO 15 AMP SENSING RANGE 286-ON DELAY, 287-OFF DELAY 326 ON DELAY, 327 OFF DELAY ±2% REPEATABILITY REPEATABILITY ±3% ± 3% REPEATABILITY FEATURES SPDT CONTACT CONFIGURATION TIMING FIELD ADJUSTABLE BY TIMING FIELD ADJUSTABLE BY KNOB OR EXTERNAL RESISTOR KNOB OR EXTERNAL RESISTOR FIELD ADJUSTABLE WITH KNOB FIXED VERSIONS AVAILABLE FIXED VERSIONS AVAILABLE 10 AMPS SWITCHING 10 AMP SWITCHING UP TO 3 POLES UP TO 3 POLES CONTACT DATA SPDT SPDT, DPDT, 3PDT SPDT, DPDT, 3PDT CONTACT CONFIGURATION: SILVER CADMIUM OXIDE, SILVER CADMIUM OXIDE, SILVER CADMIUM OXIDE, CONTACT MATERIAL: 50 MILLIOHMS MAX. INITIAL 50 MILLIOHMS MAX. INITIAL 50 MILLIOHMS MAX. INITIAL CONTACT RESISTANCE: 10 AMPS @ 120 VAC 10 AMPS @ 120/240 VAC, 28 VDC 10 AMPS @ 120/240 VAC, 30 VDC MAX. CONTACT RATING: 6 AMPS 28 VDC 1/3 HP @ 120 VAC, 1/3 HP @ 120 VAC, 1/2 HP @ 240 VAC, 1/2 HP @ 240 VAC, COIL DATA STANDARD VOLTAGE 120 VAC 24 TO 240 VAC 24 TO 240 VAC AC: 12 TO 125 VDC 12 TO 125 VDC DC: 85 % TO 110 % OF NOMINAL 85 % TO +110 % (AC), 85 % TO +110 % (AC) INPUT VOLTAGE RANGE: 80 % TO +110 % (DC) 80 % TO +110 % (DC) OF NOMINAL OF NOMINAL REVERSE POLARITY NOT APPLICABLE YES - DC YES - DC PROTECTION: GENERAL DATA AMBIENT TEMPERATURE OPERATING: - 30˚C TO +55˚C - 10˚C TO +70˚C - 10˚C TO +70˚C STORAGE: - 40˚C TO +85˚C - 55˚C TO +85˚C - 55˚C TO +85˚C STANDARD TIMING RANGE: 1.5 TO 15 AMPS 0.1 SECOND TO 300 SECONDS 0.1 SECOND TO 300 SECONDS - - DIELECTRIC STRENGTH: 2500 V rms 1500 V rms 1500 V rms LIFE EXPECTANCY ELECTRICAL: 200,000 OPERATIONS 100,000 OPERATIONS 100,000 OPERATIONS MECHANICAL: 5,000,000 OPERATIONS 10,000,000 OPERATIONS 10,000,000 OPERATIONS AGENCY APPROVALS UL Recognized UL Recognized UL Recognized File No. E13224 File No. E62636 File No. E13224 PAGE NUMBER PAGE 18 PAGE 19 - 20 PAGE 21 - 22 4...3 CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS TIME DELAY RELAYS 236 246 & 247 VOLTAGE SENSOR L.E.D. STATUS LAMP L W H L W H 2.62 X 1.46 x 4.06 SEE PAGE 26 12 OR 14 PIN PLUG-IN. SQUARE BASE OR OCTAL PLUG-IN WITH INTEGRAL LOCKING CLIP INDEPENDENTLY ADJUSTABLE PICK AND RUGGED INDUSTRIAL DESIGN DROP OUT VOLTAGES STYLE 246 - ON DELAY, TIME DELAYED ACTION AVAILABLE STYLE 247 - OFF DELAY ±1% REPEATABILITY ±3% REPEATABILITY LED POWER INDICATOR 2 - 4 POLE CONTACT CONFIGURATIONS FIELD ADJUSTABLE RECESSED POTS OR KNOBS LARGE CHOICE OF OPTIONS SEE CATALOG PAGE SPDT, DPDT SILVER CADMIUM OXIDE, SILVER CADMIUM OXIDE, Your Contact for Relays GOLD DIFFUSED 50 MILLIOHMS MAX. INITIAL 50 MILLIOHMS MAX. INITIAL U. S. A. U. S. A. 10 AMPS @ 120/240 VAC, 28 VDC SPST:13 AMPS @ 120/240 VAC, 28 VDC TELEPHONE: (843) 393-5778 1/3 HP@ 120 VAC, 1/2 HP @ 240 / 480 VAC FAX: (843) 393-4123 3 AMPS @ 480 VAC.NEMA B300 PILOT DUTY WEBSITE: www.magnecraft.com DPDT:10 AMPS @ 120 / 240 VAC, 28 VDC 1/3 HP@ 120 VAC, 1/2 HP @ 240 VAC EMAIL: info@magnecraft.com NEMA B300 PILOT DUTY EUROPE EUROPE TELEPHONE: 4989 / 75080310 24 TO 240 VAC 24 TO 480 VAC FAX: 4989 / 7559344 12 TO 250 VDC 24 VDC WEBSITE: www.magnecraft.com 85 % TO +110 % (AC), - EMAIL: renatesteinback@magnecraft.de 80 % TO +110 % (DC) OF NOMINAL YES - DC YES - DC - 10˚C to +55˚C - 30˚C to +55˚C - 55˚C to +70˚C - 40˚C to +85˚C 0.1 SECOND TO 300 SECONDS SEE CATALOG PAGE - 1500 V rms 2500 V rms 100,000 OPERATIONS 100,000 OPERATIONS 10,000,000 OPERATIONS 10,000,000 OPERATIONS (DPDT) LISTED 367G UL Recognized UL Recognized UL Listed With Magnecraft Socket 246 SERIES File No. E62636 File No. E13224 PAGE 25 -26 PAGE 23 - 24 CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS 4...4 DESCRIPTIONS OF TIME DELAY FUNCTIONS APPLICATION DATA APPLICATION DATA WHAT IS A TIME DELAY RELAY: OFF-DELAY (SLOW RELEASE RELAY) A Time Delay relay is a combination of an Continuous power must be applied to input during all electromechanical output relay and a control circuit. timing sequences. Upon closure of external control switch, The control circuit is comprised of solid state output contacts transfer. Upon opening control switch, components and timing circuits that control operation the timing period begins. When timing period ends, output of the relay and timing range. Typical time delay contacts return home. To repeat this timing cycle, the functions include On-Delay, Off-Delay, Repeat cycle, control switch must be re-closed and then opened. If input One Shot, Interval, On-Delay & Off Delay (Combination) power is interrupted during timing cycle, the output and True Off Delay. Each function is explained below. contacts return to home position and the control switch Time delay relays have a broad choice of timing ranges must be closed and reopened to start the timing from the from less than one second to hours. There is a choice beginning. If the control switch closes during a timing of timing adjustments from calibrated external knob, period, timing stops and output contacts remain recessed pots or internally fixed timing. The output transferred. When control switch is opened, timing will contacts on the electromechanical output relay are start again from the beginning. The timing period can be direct wired to the output terminals. The contact extended, repeatedly using the control switch in this way load ratings are specified for each specific type of until the last initiated timing period is permitted to end time delay relay. and output contacts return home. ON INPUT TIMING FUNCTIONS: OFF POWER ON-DELAY- (SLOW OPERATE RELAY) CLOSED CONTROL OPEN SWITCH Upon application of power to the input, the time delay DELAY DELAY period begins. At the end of the time delay period, OUTPUT output contacts transfer. Input power must be removed TRANSFERRED DELAY CONTACTS to return output contacts to home position and reset HOME the control circuit. If input power is interrupted before a timing period ends, timing stops. When input power Some typical Applications: Air Conditioning, automatic is restored , timing starts from the beginning. Door Controls, Lighting Controls, burglar alarms, Vending Machines, circuits, conveyor systems, instrument control, watchdog circuits. ON INPUT OFF POWER DELAY REPEAT CYCLE (FLASHER) TRANSFERRED OUTPUT HOME Upon application of power to the input, the Off time delay CONTACTS Period begins. The contacts transfer at the end of the Off time Delay Period and the ON time delay period begins. Some typical Applications: Cascade starting, Air At the end of the ON time delay period output contacts Conditioning & heating controls, Burglar Alarms, return home and OFF time delay period begins again. Power Outage delay, instrument Control. This sequence will continue as long as input power is supplied to the Input Pins. INPUT ON POWER OFF ON ON OFF OFF OUTPUT TRANSFERRED CONTACTS HOME Some typical Applications: Signs, Product testing, signal devices, machine control, Signal warning devices, conveyor control. 4...5 DESCRIPTIONS OF TIME DELAY FUNCTIONS APPLICATION DATA APPLICATION DATA ON-DELAY & OFF-DELAY- (COMBINATION) ONE SHOT (RETRIGGERABLE) Continuous power must be applied to the input during all Continuous power must be applied to the input during timing sequences. Upon closure of the external control all timing sequences. Upon closure of external control switch, first time delay period T1 begins. When T1 switch, output contacts transfer and timing period period ends, output contacts transfer. Then, when control begins. When timing period ends, output contacts switch is opened, second delay period T2 begins. When return home. Once the timing period begins, the control T2 ends, output contacts return home. To repeat this switch may remain closed or opened without affecting timing cycle, repeat this sequence from the beginning. timing. To repeat this cycle, the control switch must If the prevailing open or closed status of the control switch be open, or opened at the end of the timing period, and is changed during either T1 or T2 Timing periods, timing then closed to start timing period over again. stops. Position of output contacts remain as they were. Returning control switch to its pre-changed position ON INPUT restarts interrupted timing period from the beginning and OFF normal timing resumes. POWER ON CONTROL INPUT CLOSED OFF SWITCH POWER OPEN CLOSED CONTROL DELAY OUTPUT OPEN DELAY TRANSFERRED SWITCH T1 CONTACTS HOME T2 TRANSFERRED OUTPUT HOME CONTACTS T1 Interrupted T2 Interrupted Some typical Applications: Vending machines, CLOSED CONTROL dispensing controls, machine control, welding control, OPEN SWITCH T1 TRANSFERRED T2 OUTPUT HOME INTERVAL CONTACTS Upon application of power to the input, the output Some typical Applications: Cascade starting & stopping contacts transfer and the delay period begins. At the of heavy loads, laboratory equipment, machine control end of the time delay period, the output contacts return home. Input power must be interrupted to recycle timer. TRUE OFF DELAY- (SLOW RELEASE) INPUT ON Upon application of power to the input, output contacts POWER OFF transfer. The delay period begins when power is removed DELAY from the input. If power is supplied to input during the TRANSFERRED OUTPUT timing period, time is reset and time delay period starts HOME CONTACTS over again when power is removed from the input. INPUT ON Some typical Applications: Machine control, End of POWER OFF process alarm, Welding control, Photographic timing. TRANSFERRED OUTPUT DELAY HOME CONTACTS Some typical Applications: Loss of power alarm control, Burglar alarms. U. S. U. S. A. A. EUROPE EUROPE TELEPHONE: (843)393-5778 TELEPHONE: 4989 / 75080310 FAX: (843)393-4123 FAX: 4989/ 7559344 WEBSITE: www.magnecraft.com WEBSITE: www.magnecraft.com EMAIL: info@magnecraft.com EMAIL: renatesteinback@magnecraft.de 4...6 CLASS OCTAL 8 & 11 PIN TIME DELAY RELAY 211 DPDT, 10 AMPS c us THE CLASS 211 TIME DELAY RELAY UL Recognized MAKES USE OF HYBRID CIRCUITRY, File No. E43641 COMBINING INTEGRATED CIRCUITS FOR A MULTITUDE OF TIMING FUNCTIONS, LISTED COMPLIES WITH REQUIREMENTS OF 367G AND THE RELIABILITY OF RELAY TECHNOLOGY. IEC STANDARDS 947-4-1 AND * 947-5-1 LOW VOLTAGE DIRECTIVE WHEN USED IEC = INTERNATIONAL WITH SOCKETS * ELECTROTECHNICAL COMMISSION 70-464-1 (8 PIN) CE TESTING AND EVALUATION * 70-465-1 (11 PIN) PERFORMED BY THE UNDERWRITERS LABORATORIES AS A THIRD PARTY PARTICIPANT GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS TIMING Operating Modes Available: On delay, off delay, Interval, one shot Timing Adjustments Available: 0.1 to 120 minutes Repeatability (Repeat Accuracy when Stabilized): ±0.1% max. or ±33 mS AC min. or± 10 mS DC. min. @ constant voltage & temperature Timing Change Over Temperature and Voltage Range: ± 10% Timing Tolerance High End: - 0 to + 40% Timing Tolerance Low End : + 0 to - 40% Reset Time: 100 milliseconds max. CONTACTS Contact Rating: 10 amps @ 120VAC / 30VDC resistive load, 1/2 Hp @ 240 VAC, 1/3 Hp @120 VAC, NEMA B300 pilot duty Contact Life: 200,000 operations @ 120VAC, 10 amps resistive load 1,000,000 operations @ 120 VAC, 5 amps resistive load 2,000,000 operations @ 120VAC, 2 amps resistive load Mechanical Life: 10,000,000 operations INPUT Operating Voltage Range: AC: 85 % to 110 %, DC: 80 % to 110 % of nominal Temperature range (Operate): - 30 ˚C to + 55˚C Temperature range (Storage): - 55˚C to + 85˚C Steady State Input Current: 80 mA @ 24 VAC, 20 mA @ 120 VAC, 15 mA @ 230 VAC, 80 mA @ 12 VDC, 50 mA @ 28 VDC, 30 mA @ 48 VDC PROTECTION Reverse Polarity: Yes - DC Transient: UL 508 surge test: 5000V for 50 uS Noise Immunity: NEMA ICS2-230 2500 VAC DIELECTRIC STRENGTH Coil to Contacts: 1500 V rms Across Open Contacts: 1000 V rms MECHANICAL Operating Position: Any Mating Sockets Enclosure: Polycarbonate dust cover 70-750D8-1, 70-750D11-1, 70-464-1, 70-465-1: SCREW/DIN Mounting: Standard 8 or 11 pin octal 70-169-1, 70-170-1: SCREW/PANEL Weight: 115 grams approx See section 8, page 7 - 12 PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com 4...7 CLASS OCTAL 8 & 11 PIN TIME DELAY RELAY 211 DPDT, 10 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 0.562 (14.2) 2.93 (74.4) WIRING DIAGRAMS 5 4 2.37 3 6 (60.3) 2 7 8 1 INPUT + - 5 4 1.75 3 6 ON DELAY (44.4) 2 7 ON-DELAY 8 1 EXTERNALCONTROL SWITCH 8 PIN OCTAL 6 5 7 4 8 3 9 EXTERNAL SWITCH SHALL NOT BE 10 CONNECTED TO ANY EXTERNAL LOAD 2 6 11 1 5 7 OR VOLTAGE. DAMAGE TO INTERNAL OFF-DELAY 1.75 4 8 COMPONENTS CAN OCCUR. (44.4) 9 INPUT 3 + - 10 2 OFF DELAY 1 11 STANDARD NOMINAL TIMING 11 PIN OCTAL PART INPUT RANGE NUMBERS VOLTAGE ON DELAY 0.1 TO 1.0 SECONDS W211ACPSOX-18 120 VAC W211ACPSOX-5 0.1 TO 10 SECONDS 120 VAC 1.0 TO 180 SECONDS W211ACPSOX-7 120 VAC W211ACPSOX-8 2.0 TO 300 SECONDS 120 VAC 1.0 TO 15 MINUTES W211ACPSOX-60 120 VAC W211ACPSOX-61 2.0 TO 30 MINUTES 120 VAC W211ACPSOX-62 4.0 TO 60 MINUTES 120 VAC 8.0 TO 120 MINUTES W211ACPSOX-63 120 VAC W211CPSOX-1 0.1 TO 10 SECONDS 24 VDC 1.0 TO 180 SECONDS W211CPSOX-3 24 VDC OFF DELAY 0.1 TO 10 SECONDS W211ACPSRX-5 120 VAC W211ACPSRX-7 1.0 TO 180 SECONDS 120 VAC 2.0 TO 300 SECONDS W211ACPSRX-8 120 VAC W211ACPSRX-60 1.0 TO 15 MINUTES 120 VAC W211CPSRX-1 0.1 TO 10 SECONDS 24 VDC 1.0 TO 180 SECONDS W211CPSRX-3 24 VDC CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS 4...8 CLASS PROGRAMMABLE TIME DELAY RELAY TDRPRO- SPDT & DPDT, 12 AMPS FEATURES BE N E F I T S 5 TIMING FUNCTIONS, TIMING RANGES FROM c us 0.1 SECONDS TO 9,990 HOURS, UNIVERSAL UL Recognized VOLTAGE INPUT AND 12 AMP OUTPUT File No. E43641 FIVE FUNCTIONS - ONE PACKAGE FOR HIGHER POWER APPLICATIONS UNIVERSAL POWER SUPPLY ALLOWS FOR PENDING INPUT VOLTAGES FROM COMPLIES WITH REQUIREMENTS OF 24 TO 240 VDC OR VAC 50/60HZ. ONE PART FOR MOST VOLTAGES IEC STANDARDS 947-4-1 AND * 947-5-1 LOW VOLTAGE DIRECTIVE CLASS “F” INSULATION SYSTEM 12 AMPS CONTACT RATING IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION THUMB WHEEL ADJUSTMENTS FOR FUNCTION AND TIMING POSITIVE POSITION THUMB WHEEL ADJUSTMENT CE TESTING AND EVALUATION * PERFORMED BY THE UNDERWRITERS LABORATORIES AS A THIRD PARTY RED L.E.D. LAMP INDICATOR STATUS L.E.D. PARTICIPANT 0.1 % ACCURACY USING A CRYSTAL CLOCK ACCURATE TIME, ALL THE TIME MANUFACTURED UNDER ISO 9002 & QS 9000 MOUNTING CLIP ALLOWS FOR VARIED PANEL THICKNESSES, PANEL CLIP INCLUDED GENERAL GENERAL SPECIFICA SPECIFICATIONS TIONS TIMING Operating Modes Available: On delay, repeat, one shot, off delay & interval Timing Adjustments: 0.1 second to 9,990 hours Repeatability: 0.1%, (Internal crystal) (Constant Voltage and Temperature) CONTACTS Contact Material: Silver cadmium oxide, gold flashed Contact Rating: 12 amps @ 120 / 240 VAC, 30 VDC resistive 1/3 Hp @ 120 VAC 1/2 Hp @ 240 VAC INPUT Voltage Range: 24 to 240 VDC / VAC ± 15%, 50/60 Hz. Temperature Range (Operate): -10˚C to +55˚C Temperature Range (Storage): -40˚C to +85˚C Transient Protection: Yes Reverse Polarity Protection: Non polarity sensitive DIELECTRIC STRENGTH Between Output Poles: 1,500 V rms Between Input and Output: 1,500 V rms LIFE EXPECTANCY Electrical: 100,000 operations Mechanical: 10,000,000 operations MISCELLANEOUS Operating Position: Any Mating Sockets Enclosure: Gray polycarbonate 70-750D8-1, 70-750D11-1, Mounting: 70-464-1, 70-465-1: SCREW/DIN 11 pin octal plug-in, 8 pin octal 70-169-1, 70-170-1: SCREW/PANEL 1.8 x 1.8 (45 x 45) panel cutout. See section 8, page 7 - 12 Weight: 122 grams approx. PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com 4...9 CLASS PROGRAMMABLE TIME DELAY RELAY TDRPRO- SPDT & DPDT, 12 AMPS OUTLINE DIMENSIONS RED L.E.D. DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). LAMP INDICATOR 2.83 MAX. 5 FUNCTION 0.64 1.87 1.76 (71.9) (16.3) (47.49) (44.7) Magnecraft Struthers-Dunn 6 5 7 A - ON DELAY B - REPEAT TDRPRO-5000 8 C - INTERVAL 4 D - OFF DELAY 1.76 1.87 E - ONE SHOT TIME TIME 3 9 (44.7) (47.49) SET BASE 2 10 B 00 2 S 1 11 3.15 MAX. 11 PIN OCTAL POSITIVE POSITION (80.0) THUMB WHEEL BASE ADJUSTMENTS 3 FUNCTION PANEL CUTOUT Magnecraft FOR PANEL MOUNTING Struthers-Dunn A - ON DELAY 1.80 B - REPEAT TDRPRO-5002 (45.72) C - INTERVAL 1.87 TIME TIME (47.49) SET BASE A 00 2 S 1.80 (45.72) WIRING DIAGRAMS VIEWED FROM PIN END EXTERNAL CONTROL SWITCH EXTERNAL EXTERNAL CONTROL SWITCH CONTROL SWITCH 4 5 6 5 4 5 7 3 6 4 8 3 6 3 9 2 7 2 7 10 2 1 8 8 1 11 1 INPUT INPUT INPUT EXTERNAL SWITCH SHALL NOT BE TDRPRO-5002 TDRPRO-5001 TDRPRO-5000 CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR. STANDARD NOMINAL TIMING PART INPUT RANGE NUMBERS VOLTAGE 5 FUNCTION - 11 PIN 24-240 VAC 0.1 SECOND TO 9,990 HOURS TDRPRO-5000 24-240 VDC 5 FUNCTION - 8 PIN 24-240 VAC 0.1 SECOND TO 9,990 HOURS TDRPRO-5001 24-240 VDC 3 FUNCTION - 8 PIN 24-240 VAC 0.1 SECOND TO 9,990 HOURS TDRPRO-5002 24-240 VDC 4...10 CLASS MINIATURE TIME DELAY RELAY 67 DPDT, 5 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). UL Recognized 0.734 File No. E43641 0.400 0.458 (18.6) (10.1) (11.6) RECESSED SCREW CHASSIS CUTOUT 1.18 MAX. ADJUSTMENT 0.200 FOR PANEL MOUNTING (30.2) (5.1) 0.56 0.790 (14.2) (198) 0.280 (7.11) 1.37 0.352 0.656 (34.9) 0.17 (4.3) (8.9) (16.7) 3-48 UNC THREAD 0.140 (3.5) 0.109 DIA (2.77) 0.734 0.094 (2.3) (18.6) GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS TIMING Operating Modes Available: On delay, Timing Adjustments Available: 0.1 to 450 seconds Repeatability (Repeat Accuracy when Stabilized): ± 2% max. @ nominal voltage @ 25˚C Reset time: 100 milliseconds max. CONTACTS Contact Rating: 5 Amps @ 120VAC / 28 VDC resistive Contact Life: 50,000 operations @ 120 VAC, 5 amps resistive 1,500,000 operations @ 120 VAC, 2 amps resistive load 12,000,000 operations @ 120 VAC, 1 amp resistive load WIRING DIAGRAM Mechanical Life: 10,000,000 operations 16 6 7 INPUT Operating Voltage Range: AC: 85 % to 110 %, DC: 80 % to 110 % of nominal 14 15 5 Temperature Range (Operate): -30˚C to + 55˚C Temperature Range (Storage): -50˚C to +85˚C Steady State Input Current: 40 mA @ 24 VDC, 80 mA @ 12 VDC 4 - 1+ PROTECTION Reverse Polarity: Yes - DC Transient: Twice nominal voltage for 1 millisecond Chassis Mount Socket: 70-307-1 PCB Socket: DIELECTRIC STRENGTH 70-308-1 Coil to Contacts: 500 V rms See section 8, page 25. 26 Across Open Contacts: 1250 V rms NOMINAL STANDARD TIMING INPUT PART MECHANICAL RANGE NUMBERS VOLTAGE Operating Position: Any Enclosure: Polycarbonate dust cover ON DELAY Mounting: Socket plug-in/solder also available 12 VDC 0.1 TO 30 SECONDS W67CPSOX-1 with printed circuit terminals 0.1 TO 30 SECONDS 24 VDC W67CPSOX-2 Weight: 35.2 grams approx 4PDT AVAILABLE CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS 4...11 CLASS OCTAL 8 PIN REPEAT CYCLE TIMER RELAY 222 DPDT, 5 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 2.93 1.75 0.562 UL Recognized (74.4) (44.4) (14.2) File No. E43641 4 5 3 6 COMPLIES WITH REQUIREMENTS OF 2.37 INDEPENDENT TIME (60.35) 2 7 IEC STANDARDS 947-4-1 AND * 947-5-1 LOW VOLTAGE DIRECTIVE 8 1 SETTINGS FOR BOTH IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION “ON” AND “OFF” CE TESTING AND EVALUATION * PERFORMED BY THE UNDERWRITERS TIMING RANGES 8 PIN OCTAL LABORATORIES AS A THIRD PARTY PARTICIPANT GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS TIMING Operating Modes Available: Repeat cycle timing Timing Adjustments Available: 0.1 to 30 minutes Repeatability (Repeat Accuracy when Stabilized): ±0.1% Max. or ± 33 mS AC min. or ± 10 mS DC. min. @ constant voltage & temperature Timing change over temperature and voltage range: ± 10% Timing Tolerance high end of range: - 0 to + 40% Timing Tolerance low end of range: + 0 to - 40% Reset time: 100 milliseconds max. CONTACTS Contact Rating: 10 Amps @ 120 / 240 VAC, 30 VDC resistive load, 1/2 Hp @ 240 VAC, 1/3 Hp @120 VAC, NEMA B300 pilot duty Contact Life: 200,000 operations @ 120VAC, 10Amp resistive load 1,000,000 operations @ 120 VAC, 5 Amp resistive load 2,000,000 operations @ 120VAC, 2 Amps resistive load WIRING DIAGRAM Mechanical Life: 10,000,000 operations INPUT 5 Operating Voltage Range: 4 AC: 85% to 110%, DC: 80% to 110% of nominal 3 6 Temperature Range (Operate): -30˚C to +55˚C Temperature Range (Storage): -55˚C to +85˚C 2 7 Steady State Input Current: 25 mA @ 120 VAC, 25 mA @ 240 VAC, 8 1 80 mA @ 12 VDC, 40 mA @ 24 VDC, 24 mA @ 48 VDC. INPUT PROTECTION Reverse Polarity: Yes - DC Transient: UL 508 saurge test: 5000V for 50 uS Mating Sockets Noise Immunity: NEMA ICS2-230 2500 VAC 70-750D8-1, 70-750D11-1, 70-464-1, 70-465-1: SCREW/DIN 70-169-1, 70-170-1: SCREW/PANEL DIELECTRIC STRENGTH See section 8, page 7 - 12 Coil to Contacts: 1500 V rms Across Open Contacts: 1000 V rms STANDARD NOMINAL TIMING PART INPUT RANGE NUMBERS VOLTAGE MECHANICAL Operating Position: Any REPEAT CYCLE Enclosure: Polycarbonate dust cover W222ACPFX-11 0.1 TO 10 SECONDS 120 VAC Mounting: 8 pin octal W222ACPFX-16 3 TO 300 SECONDS 120 VAC Weight: 132 grams approx. W222ACPFX-27 2 TO 30 MINUTES 120 VAC CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS 4...12 CLASS SQUARE BASE TIME DELAY RELAYS 388 DPDT, 12 AMPS UL Recognized File No. E52197 "ON" OR "OFF" DELAY FUNCTIONS EXTERNAL RESISTANCE ADJUSTABLE ± 3 % REPEATABILITY DPDT, 12 AMP COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND * 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION CE TESTING AND EVALUATION * PERFORMED BY THE UNDERWRITERS LABORATORIES AS A THIRD PARTY PARTICIPANT GENERAL GENERAL SPECIFICA SPECIFICATIONS TIONS TIMING On delay, off delay Operating Modes Available: 0.1 to 120 seconds Timing Adjustments Available: ±3% @ nominal voltage @ 25˚C Repeatability: Percent Timing Change Over ±10% Temperature and Voltage Range: -0 to +40% Timing Tolerance High End : +0 to -40% Timing Tolerance Low End: CONTACTS 12 amps @ 120 VAC/28 VDC resistive Contact Rating: 1/3 HP, 120 VAC, 1/2 HP, 240 VAC B300 pilot duty. 100,000 operations @ 120 VAC Contact Life: 12 amps resistive load. 1,000,000 operations @ 28 VDC 5 amps resistive load. 5,000,000 operations Mechanical Life: INPUT AC: 85% to 110%, Operating Voltage Range: DC: 80% to 110% of nominal - 30˚C to + 55˚C Temperature Range (Operate): - 55˚C to + 85˚C Temperature Range (Storage): 20 mA @ 120 VAC, 60 mA @ 24 VDC Steady State Input Current: PROTECTION Yes - DC Reverse Polarity: Twice nominal voltage for 1 millisecond Transient: DIELECTRIC STRENGTH 1500 V rms Coil to Contacts: 1000 V rms Across Open Contacts: Mating Sockets MECHANICAL 70-463-1: SCREW/DIN Any Operating Position: 70-124-1: SOLDER Polycarbonate dust cover Enclosure: 70-178-1, 70-178-2: PRINTED CIRCUIT 0.187 x 0.020” quick connect terminals 70-124-2: QUICK CONNECT Terminals: See section 8, page 16, 17 96 grams approx. Weight: PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com 4...13 CLASS SQUARE BASE TIME DELAY RELAYS 388 DPDT, 12 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). SOLDER / PLUG-IN TERMINALS 0.187 X 0.020 (4.74 X 0.508) QUICK CONNECT TERMINALS 1.53 MAX. (38.8) 0.156 (3.9) 2.50 MAX. (63.5) WIRING DIAGRAMS 2.90 MAX. (73.8) EXTERNAL RESISTOR 1.53 MAX. 1.90 MAX. (38.8) (48.4) 3 1 2 1 2 3 5 6 4 4 5 6 1.40 7 8 9 7 8 9 (35.5) 0.020 (0.508) A B A B INPUT ON DELAY THE PLUG-IN STYLE TIMER HAS THE SAME CASE EXTERNAL RESISTOR DIMENSIONS AS THE FLANGE MOUNT STYLE EXCEPT IT HAS NO FLANGE AND IT IS ALSO SOCKET MOUNTABLE. 3 1 2 5 6 4 7 8 9 EXTERNAL A B CONTROL EXTERNAL SWITCH SHALL NOT BE SWITCH CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE. DAMAGE TO INTERNAL INPUT COMPONENTS CAN OCCUR. OFF DELAY STANDARD NOMINAL TIMING EXTERNAL PART INPUT RANGE RESISTOR NUMBERS VOLTAGE ON DELAY PLUG-IN STYLE W388ACPSOX-1 0.1 TO 10 SECONDS 20,000 Ω 120 VAC W388ACPSOX-2 120 VAC 1.0 TO 120 SECONDS PER SECOND W388CPSOX-1 0.1 TO 10 SECONDS 16,000 Ω 24 VDC W388CPSOX-2 24 VDC 1.0 TO 120 SECONDS PER SECOND ON DELAY SURFACE MOUNT FLANGE STYLE W388ACQSOX-1 0.1 TO 10 SECONDS 120 VAC 20,000 Ω W388ACQSOX-2 120 VAC 1.0 TO 120 SECONDS PER SECOND W388CQSOX-2 1.0 TO 120 SECONDS 24 VDC OFF DELAY PLUG-IN STYLE W388CPSRX-22 1.0 TO 120 SECONDS 16,000 Ω 24 VDC PER SECOND CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS 4...14 CLASS SQUARE BASE TIME DELAY RELAY 388 DPDT, 12 AMPS THE CLASS 388 IS KNOB ADJUSTABLE "ON" OR "OFF" DELAY FUNCTIONS. UL Recognized File No. E43641 DPDT, 12 AMP CONTACTS, ± 0.1 % REPEATABILITY, COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND * 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION CE TESTING AND EVALUATION * PERFORMED BY THE UNDERWRITERS LABORATORIES AS A THIRD PARTY PARTICIPANT GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS TIMING Operating Modes Available: On delay, off delay Timing Adjustments Available: 0.1 to 30 minutes Repeatability: ±0.1% ±33 mS AC min. or ± 10 mS DC @ constant voltage & temperature Timing Change Over Temperature and Voltage Range: ±10% Timing Tolerance High End: -0 to +40% Timing Tolerance Low End: +0 to -40% Reset Time: 100 mS max. CONTACTS Contact Rating: 12 amps @ 120 VAC / 28 VDC resistive 1/3 Hp, 120 VAC, 1/2 Hp, 240 VAC NEMA B300 pilot duty Contact Life: 100,000 operations @ 120 VAC, 12 amps resistive load 1,000,000 operations @ 120 VAC, 5 amps resistive load 2,000,000 operations @ 120 VAC, 2 amps resistive load Mechanical Life: 5,000,000 operations INPUT Operating Voltage Range: AC: 85% to 110%, DC: 80% to 110% of nominal Temperature Range (Operate): - 30˚C to + 55˚C Temperature Range (Storage): - 55˚C to + 85˚C Steady State Input Current: 15 mA @ 230 VAC, 20 mA @ 120 VAC, 80 mA @ 24 VAC, 20 mA @ 48 VDC, 60 mA @ 24 VDC, 120 mA @ 12 VDC PROTECTION Reverse Polarity: Yes - DC Transient: UL 508 Surge test: 5000V for 50 uS Noise Immunity: NEMA ICS2-230: 2500 VAC DIELECTRIC STRENGTH Coil to Contacts: 2000 V rms Across Open Contacts: 1000 V rms Mating Sockets MECHANICAL 70-463-1: SCREW/DIN Mounting Position: Any 70-124-1: SOLDER 70-178-1, 70-178-2: PRINTED CIRCUIT Enclosure: Polycarbonate dust cover 70-124-2: QUICK CONNECT Terminals: 0.187 x 0.020” quick connect terminals See section 8, page 16, 17 Weight: 96 grams approx. 4...15 PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com CLASS SQUARE BASE TIME DELAY RELAY 388 DPDT, 12 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 1.53 0.625 0.312 (38.8) (15.8) (7.9) 1 2 3 4 5 6 1.40 7 8 9 (35.7) A B 2.90 MAX. (73.8) 0.187 x 0.020 (4.74 x 0.508) QUICK CONNECT TERMINALS WIRING DIAGRAMS 1 2 3 5 6 4 7 8 9 A B INPUT ON DELAY 1 2 3 5 6 4 7 8 9 EXTERNAL SWITCH SHALL NOT BE A B CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE. DAMAGE TO INTERNAL EXTERNAL CONTROL COMPONENTS CAN OCCUR. SWITCH INPUT OFF DELAY STANDARD NOMINAL TIMING PART INPUT RANGE NUMBERS VOLTAGE ON DELAY W388ACPSOX-42 0.1 TO 10 SECONDS 120 VAC W388ACPSOX-44 1.0 TO 180 SECONDS 120 VAC OFF DELAY W388CPSRX-2 0.1 TO 10 SECONDS 24 VDC W388CPSRX-4 1.0 TO 180 SECONDS 24 VDC CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS 4...16 CLASS TRUE OFF TIME DELAY RELAY 388 DPDT, 12 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 0.658 (15.8) 1.53 2.90 MAX. 0.312 (38.8) (73.8) (7.9) UL Recognized File No. E43641 1 2 3 4 5 6 1.40 (35.7) 7 8 9 COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND * A B 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION THE CLASS 388 ADJUSTABLE TRUE CE TESTING AND EVALUATION * PERFORMED BY THE UNDERWRITERS LABORATORIES AS A THIRD PARTY OFF DELAY RELAY COMBINES A SOLID STATE PARTICIPANT TIMING CIRCUIT WITH A STATE OF THE ART MAGNETIC LATCHING RELAY. THIS COMBINATION ALLOWS THE RELAY TO PULL-IN WHEN POWER IS APPLIED TO THE INPUT. TIMING STARTS WHEN POWER IS REMOVED FROM THE INPUT AND AT THE END OF THE PRESET TIMING PERIOD 0.187 X 0.020 (4.74 X 0.508) QUICK CONNECT TERMINALS THE RELAY WILL DROPOUT. GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS TIMING Operating Modes Available: True off delay Timing Adjustments Available: 0.1 to 5 Minutes Repeatability (Repeat Accuracy when Stabilized): ±3% @ nominal voltage & 25˚C Reset Time: 100 mS max. CONTACTS Contact Rating: 12 amps @ 120 VAC/28 VDC resistive WIRING DIAGRAM 1/3 Hp, 120 VAC, 1/2 Hp, 240 VAC NEMA B300 pilot duty 3 2 1 Contact Life: 100,000 operations @ 120 VAC 12 amps resistive load 5 6 1,000,000 operations @ 120 VAC 5 amps resistive load 4 2,000,000 operations @ 120 VAC 2 amps resistive load 8 9 Mechanical Life: 5,000,000 operations 7 A INPUT B + - Temperature Range Operate: - 10˚C to + 55˚C INPUT Temperature Range Storage: - 40˚C to + 85˚C Input Current: 10 mA @ 120VAC, 15 mA @ 24VDC Mating Sockets PROTECTION 70-463-1: SCREW/DIN 70-124-1: SOLDER Reverse Polarity: Yes - DC 70-178-1, 70-178-2: PRINTED CIRCUIT Transient: 2000 VAC for 50 microseconds 70-124-2: QUICK CONNECT See section 8, page 16, 17 DIELECTRIC STRENGTH STANDARD NOMINAL Coil to Contacts: 2000 V rms TIMING PART INPUT RANGE Across Open Contacts: 1000 V rms NUMBERS VOLTAGE AC OPERATED MECHANICAL Enclosure: Polycarbonate dust cover W388ACPSRX-29 120 VAC 0.1 TO 10 SECONDS W388ACPSRX-30 0.6 TO 60 SECONDS Mounting: Square base plug-in 120 VAC DC OPERATED Terminals: 0.187" X 0.020" quick connect terminals W388CPSRX-35 0.1 TO 10 SECONDS 24 VDC Weight: 96 grams approx. W388CPSRX-36 0.6 TO 60 SECONDS 24 VDC PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com 4...17 CLASS CURRENT SENSING RELAY 235 SPDT, 1.5 TO 15 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 1.53 2.90 MAX. 0.312 UL Recognized 0.625 (38.8) (73.8) (7.9) File No. E62636 (15.8) 1 2 3 4 5 6 1.40 (35.7) 7 8 9 A B 1.31(33.3) CLASS 235 CURRENT SENSING RELAY 0.875 ANTI-ROTATION TAB (22.2) (1/4”TERMINAL STYLE) COMBINES A SOLID STATE SENSOR WITH A SPDT, 10 AMPS RELAY. THE SENSOR IS FIELD ADJUSTABLE FOR DETECTING AC CURRENT LEVELS IN EQUIPMENT. 6-32 TAPPED HOLE (1/4”TERMINAL STYLE) GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS CURRENT SENSING: Sense Current Range: 1.5 to 15 amps Repeatability: ±2% @ constant voltage & temperature WIRING DIAGRAM ±10% over voltage & temperature range CONTACTS 1 2 3 Contact Rating: 10 amps @ 120 VAC, 6 amps @ 28 VDC 5 6 4 Transient: 2000 V rms for 5 microseconds Contact Life: 200,000 operations @ rated load SUPPLY 7 8 9 Mechanical Life: 5,000,000 operations @ no load VOLTAGE LOAD A B INPUT Input Current: 15 mA (1.7 VA) INPUT Current Sensor Resistance: 5 milliohms CONTINUOUS VOLTAGE MUST BE Temperature Range Operate: -10˚C to +55˚C SUPPLIED TO INPUT. Temperature Range Storage: -40˚C to +85˚C Mating Sockets DIELECTRIC STRENGTH 70-463-1: SCREW/DIN Coil to Contacts: 2500 V rms 70-124-1: SOLDER 70-178-1, 70-178-2: PRINTED CIRCUIT Across Open Contacts: 500 V rms 70-124-2: QUICK CONNECT See section 8, page 16, 17 MECHANICAL STANDARD NOMINAL Enclosure: Polycarbonate dust cover CURRENT TERMINAL PART INPUT Terminals: 0.187 or 0.250 quick connect RANGE SIZE NUMBERS VOLTAGE terminals Mounting: Square base plug-in Mounting Bracket: Optional 0.250” W235ACX-2 120 VAC 1.5 TO 15 AMPS Weight: 113 grams approx. W235ACX-3 120 VAC 0.187” 1.5 TO 15 AMPS CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS 4...18 CLASS SQUARE BASE TIME DELAY RELAYS 286 & 287 SPST, DPDT & 3PDT, 10 AMPS UL Recognized THE CLASS 286 ON DELAY & 287 OFF DELAY File No. E13224 TIME DELAY RELAYS HAVE TIMING RANGES FROM 0.1 TO 300 SECONDS. THE 286 TIMER HAS UP TO THREE POLES AND THE 287 TIMER HAS UP TO TWO POLES. THE 286 & 287 TIME DELAY RELAYS ARE RATED AT 10 AMPS, 120/240 VAC, 28 VDC. GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS TIMING Operating Modes Available: On delay, off delay, Interval Timing Adjustments Available: 0.1 to 300 minutes Repeatability (Repeat Accuracy when Stabilized): ± 3% @ 20˚C to 25˚C (AC +16 mS) Reset time: 150 mS max. CONTACTS Contact Material: Silver cadmium oxide. Contact Rating: 10 amps @ 120 / 240 VAC 10 amps @ 28 VDC 1/3 Hp @ 120 VAC 1/2 Hp @ 240 VAC Contact Life: 100,000 operations @ rated load Mechanical Life: 10,000,000 operations @ no load INPUT Operating Voltage Range: AC: 85% , DC: 80% of nominal Temperature Range (Operate): 10˚C to +70 ˚C Max. Allowed Voltage: 110% of nominal voltage PROTECTION Reverse Polarity: Yes - DC Transient: 2000 V for 5 mS DIELECTRIC STRENGTH Mating Sockets Coil to Contacts: 1500 V rms 70-463-1: SCREW/DIN 70-124-1: SOLDER Across Open Contacts: 500 V rms 70-178-1, 70-178-2: PRINTED CIRCUIT 70-124-2: QUICK CONNECT MECHANICAL See section 8, page 16, 17 Operating Position: Any Enclosure: Clear polycarbonate Weight: 142 grams approx. PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com 4...19 CLASS SQUARE BASE TIME DELAY RELAYS 286 & 287 1, 2 & 3 POLE, 10 AMPS ORDERING CODE FOR RELAYS ORDERING CODE FOR RELAYS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 286 XAX C 001 F 120A 0.625 2.90 MAX. CLASS: 0.281 TYP. (15.8) (73.66) (7.14) 286: ON DELAY 287: OFF DELAY 1 2 3 CONTACT ARRANGEMENTS: 4 5 6 1.375 MAX. XAX: SPDT (34.9) 7 8 9 XBX: DPDT XCX: 3PDT (286 ONLY) A B MOUNTING OPTIONS: 0.187 x 0.020 (4.74 x 0.508) C: PLUG-IN QUICK CONNECT TERMINALS NOTE 1 C1 : 1BRACKET NOTE 1 CS1 : TOP STUD C2: SIDE TAPPED HOLE CODE C CS2: SIDE STUD TIMING RANGES: 1.50 MAX. 0.1 - 1.0 SEC: CODE 001 (38.1) 0.2 - 2.0 SEC: CODE 002 1.0 - 10 SEC: CODE 010 3.0 - 30 SEC: CODE 030 6.0 - 60 SEC: CODE 060 18 - 180 SEC: CODE 180 30 - 300 SEC: CODE 300 (F * Models) - timing code does not apply. Specify single delay time requirement ADJUSTMENT OPTIONS (R ** Models)- Available only for SPDT and DPDT models. External potentiometer required. ADJUSTMENT KNOB): NO CODE Example of typical fixed time delay relay part number- 286XBXCS1-3.5F-120A (ON DELAY, DPDT, TOP STUD, 3.5 SEC FIXED, 120 VAC COIL INPUT) FIXED DELAY: SPECIFY FIXED TIME & CODE F * REMOTE ADJUSTMENT: CODE R ** NOTE 1: OPERATING VOLTAGE: BRACKET & TOP STUD NOT AVAILABLE WITH 24, 48, 120, 240 ADD "A" FOR AC COILS ADJUSTABLE TIMING. 12, 24, 48, 115-125 ADD "D" FOR DC COILS WIRING DIAGRAM EXTERNAL EXTERNAL EXTERNAL SWITCH RESISTOR RESISTOR 287 MODEL 2 3 1 1 2 3 ONLY 4 5 6 4 5 6 3 1 2 7 8 9 5 6 7 8 9 4 7 8 A B 9 A B INPUT A B INPUT EXTERNAL SWITCH INPUT 287 MODELONLY 286XAX (SPDT) 286XBX (DPDT) 286XCX (3PDT) 287XAX (SPDT) 287XBX (DPDT) 4...20 CLASS OCTAL 8 & 11 PIN TIME DELAY RELAYS 326 & 327 SPDT, DPDT & 3PDT 10 AMPS ORDERING CODE FOR RELAYS ORDERING CODE FOR RELAYS 326 XAX 48P 001 F 120A CLASS: UL Recognized 326: ON DELAY File No. E13224 327: OFF DELAY CONTACT ARRANGEMENTS: XAX: SPDT XBX: DPDT XCX: 3PDT CONSTRUCTION STYLE: OCTAL STYLE PLUG-IN: CODE 48P NON STANDARD WIRING: CODE 48P-K TIMING RANGES: 0.1 - 1.0 SEC: CODE 001 0.2 - 2.0 SEC: CODE 002 1.0 - 10 SEC: CODE 010 3.0 - 30 SEC: CODE 030 6.0 - 60 SEC: CODE 060 18 - 180 SEC: CODE 180 30 - 300 SEC: CODE 300 ADJUSTMENT: ADJUSTMENT KNOB): NO CODE F * Models) - timing code does not apply. Specify single delay time requirement (R ** Models)- Available only for SPDT and DPDT models. FIXED DELAY: SPECIFY FIXED TIME & CODE F * External fixed or Adjustable resistor required. REMOTE ADJUSTMENT: CODE R ** Example of typical fixed time delay relay part number - 326XBX48P3.5F-120A (ON DELAY, DPDT, OCTAL PLUG, 3.5 SEC FIXED, 120 VAC POWER INPUT) OPERATING VOLTAGE: 24, 48, 120, 240 ADD "A" FOR AC COILS 12, 24, 48, 115-125 ADD "D" FOR DC COILS GENERAL GENERAL SPECIFICA SPECIFICATIONS TIONS TIMING Repeatability: DC: ± 3% @ 20˚C, AC: ± 3% +16 mS @ 20˚C Accuracy: Adjustable ± 10% within temperature & voltage range Switching Time of Output Relay: 20 mS Min. Waiting Time Before Starting Next Cycle (Reset Time): 100 mS (for timing cycle up to 60 sec) 150 mS (for timing cycle 60 to 300 sec) CONTACTS Contact Material: Silver cadmium oxide Rating: 10 amps @ 120 / 240 VAC, 10 amps @ 30 VDC, 1/3 Hp @ 120 VAC, 1/2 Hp @ 240 VAC Electrical Life: 100,000 operations @ rated load Mechanical Life: 10,000,000 operations @ no load INPUT Nominal Voltage: AC: 24 to 240, DC: 12 to 125 Minimum Oper. Voltage: AC - 85% of nominal; DC - 80% of nominal Max. Allowed Voltage: 110% of nominal voltage Ambient Temperature Rating: -10˚C to +70 ˚C DIELECTRIC STRENGTH Across Open Contacts: 500 V rms Coil to Contacts: 1500 V rms Mating Sockets Transient Protection: 2000 VAC for 5 mS 70-750D8-1, 70-750D11-1, 70-464-1, 70-465-1: SCREW/DIN 70-169-1, 70-170-1: SCREW/PANEL MECHANICAL See section 8, page 7 - 12 Enclosure: Clear polycarbonate Weight: 142 grams approx. 4...21 PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com CLASS OCTAL 8 & 11 PIN TIME DELAY RELAYS 326 & 327 1, 2 & 3 POLE, 10 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 0.625 (15.87) 3.00 MAX. (76.2) 6 4 5 5 7 3 6 4 8 1.375 3 9 (34.9) 2 7 10 2 8 1 1 11 1.375 1.375 (34.9) (34.9) 11 PIN OCTAL OFF-DELAY 8 PIN OCTAL ON-DELAY ✱ External Resistor for remote timing adjustment on models 326 or 327 with Code R. WIRING DIAGRAMS ✱✱ Observe Polarity on DC input models MODELS WITH INTERNAL TIMING RESISTOR OFF-DELAY ON-DELAY EXTERNAL SWITCH 6 5 4 5 6 4 5 7 5 7 4 8 3 6 Jumper 8 3 6 4 3 9 3 9 2 7 2 7 10 2 10 2 1 11 8 1 11 1 8 1 INPUT INPUT INPUT INPUT 327XBX48P-K 326XAX48P 326XBX48P 327XCX48P NON STANDARD MODELS WITH EXTERNAL (REMOTE) TIMING RESISTOR ON-DELAY OFF-DELAY EXTERNAL EXTERNAL EXTERNAL EXTERNAL * * * RESISTANCE RESISTANCE * RESISTANCE RESISTANCE 6 6 5 7 5 7 4 5 4 5 4 8 4 8 3 6 3 6 3 9 9 3 10 2 7 2 2 7 10 2 1 11 1 11 1 8 1 8 EXTERNAL EXTERNAL SWITCH INPUT INPUT INPUT INPUT SWITCH 326XAX48P-R 326XBX48P-R 327XAX48P-R 327XBX48P-R CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS 4...22 CLASS INDUSTRIAL DELAY TIMER RELAYS 246 & 247 DPDT, 3PDT, 4PDT, DPDT WITH 1 N.C UL CONTACT LOAD RATINGS TABLE & 1 N.O., DPDT WITH 2 N.O., 10 AMPS LOAD VOLTAGE TYPE OF CURRENT OR LOAD POLES INSTANTANEOUS CONTACTS AVAILABLE FREQUENCY HORSE POWER LOAD VOLTAGE 10 AMP 50/60 Hz RESISTIVE 120 VAC 5 AMP 50/60 Hz RESISTIVE 240 VAC Class 246 CSA DC RESISTIVE 10 AMP 28 VDC Certified DC ALL 0.5 AMP RESISTIVE 125 VDC UL Recognized 3 AMP 50/60 Hz INDUCTIVE STYLES 120 VAC File No. E13224 1 AMP 50/60 Hz INDUCTIVE 240 VAC LISTED DC INDUCTIVE 3 AMP 28 VDC 367G DC 0.1 AMP INDUCTIVE 125 VDC SUFFIX “69” WITH BLOWOUT MAGNET FOR DC SWITCHING (NOT UL OR CSA) UL Listed when SPST-NO 1.5 AMP DC RESISTIVE CONTACTS CAN SWITCH 30 AMP used with type 125 VDC SPST-NO-DM DC RESISTIVE 4 AMP 125 VDC LOADS AND CARRY 10 AMPS 27390 socket DC SPST-NO 0.5 AMP RESISTIVE 250 VDC CONTINUOUSLY AT VOLTAGES SPST-NO-DM 1.5 AMP DC RESISTIVE 250 VDC SHOWN IN UL CONTACT LOAD 0.5 AMP DC INDUCTIVE SPST-NO 125 VDC RATINGS TABLE. DC INDUCTIVE SPST-NO-DM 1.5 AMP 125 VDC DC SPST-NO 150 mA INDUCTIVE 250 VDC 0.5 AMP DC INDUCTIVE SPST-NO-DM 250 VDC THE CLASS 246 & 247 TIME DELAY RELAYS ARE ON-DELAY OR OFF DELAY, WITH TIMING RANGES FROM 0.1 TO 300 SECONDS. BOTH TIMERS INCORPORATE THE PROVEN INDUSTRIAL WORKHORSE CLASS 219 FRAME ALONG WITH A SOLID STATE TIMING MODULE. PRODUCTS ARE AVAILABLE WITH A VARIETY OF POLE AND CONTACT CONFIGURATIONS. A LARGE CHOICE OF OPTIONS IS AVAILABLE AND SWITCH UP TO 30 AMP LOADS. GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS TIMING Operating Modes Available: On delay, off delay Repeatability: ± 3% @ 25˚C (AC +16 mS) Accuracy: Adjustable ± 10% within temperature & voltage range Recycle Time: 150 mS 60 to 300 Sec False Contacting: No false contacting if power is interrupted during timing cycle CONTACTS Contact Material: Silver cadmium oxide - gold diffused Electrical Life: 100,000 operations @ rated load Mechanical Life: 10,000,000 operations @ no load INPUT Coil Voltage Minimum Operate Voltage: AC - 85% of nominal DC - 80% of nominal Ambient Temperature Rating: AC: -10˚C to +45˚C @ rated operation, DC: -10˚C to +70˚C @ rated operation Max. Allowed Voltage: 110% of nominal voltage PROTECTION Reverse Polarity: Yes - DC DIELECTRIC STRENGTH Across Open Contacts: 500 V rms Coil to Contacts: 1500 V rms Transient Protection: 2000V for 5 mS 12 Pin Versions Mating Socket: 27390 14 Pin Versions Mating Socket: MECHANICAL 33377 Enclosure: Clear polycarbonate See section 8, page 27 Weight: 227 grams approx. 4...23 PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com CLASS INDUSTRIAL DELAY TIMER RELAYS 246 & 247 DPDT, 3PDT, 4PDT ORDERING CODE FOR RELAYS ORDERING CODE FOR RELAYS DPDT WITH 1 N.C & 1 N.O., 247 XBX P L -010 -120A DPDT WITH 2 N.O., 10 AMPS CLASS: 246: ON DELAY, OUTLINE DIMENSIONS 247: OFF DELAY, DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). CONTACT ARRANGEMENTS: 2.625 MAX XBX: (2 FORM "C") (66.6) XCX: (3 FORM "C") 0.678 ABA: (1 FORM A & 2 FORM C & 1 FORM B). (17.2) BBX: (2 FORM A & 2 FORM C) 246 ONLY. STANDARD FEATURES: PLUG-IN WITH POLYCARBONATE COVER: CODE P OPTIONS: INDICATOR LAMP: CODE L 3.75 MANUAL ACTUATOR: CODE M (95.2) BIFURCATED CONTACTS (5 AMPS MAX): CODE 33 PERMANENT MAGNET, BLOWOUT: CODE 69 4.56 ADJUSTMENT KNOB): NO CODE (115.8) REMOTE ADJ. (EXT POT REQUIRED) : CODE R LOCKING SHAFT POT: CODE 8 INSTANTANEOUS CONTACTS: CALL TIMING RANGES: 0.1 - 1.0 SEC: CODE 001 0.2 - 2.0 SEC: CODE 002 1.0 - 10 SEC: CODE 010 LOCKING 3.0 - 30 SEC: CODE 030 CLIP 6.0 - 60 SEC: CODE 060 18 - 180 SEC: CODE 180 30 - 300 SEC: CODE 300 1.468 OVER 300 SEC: CALL (37.2) FIXED: CODE F (EX. 3F) 12 11 10 9 8 7 OPERATING VOLTAGE: 24, 48, 120, 240 ADD "A" FOR AC COILS 12, 24, 48, 110-125, 250 ADD "D" FOR DC COILS WIRING DIAGRAMS 1 6 1 6 1 6 1 EXT. TRIGGER 6 EXT. TRIGGER 12 7 12 7 12 7 12 7 247XBXP 246BBXP 246XBXP 247XCXP 7 1 1 6 XDXP 4PDT 8 14 12 7 246ABAP CALL FACTORY FOR OTHER AGASTAT ALTERNATIVES 4...24 CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS TIME MOD TIME TIME MOD MOD TIME MOD TIME MOD 6 5 4 3 2 1 CLASS VOLTAGE SENSING RELAYS 236 SPDT, 13 AMPS & DPDT, 10 AMPS CLASS 236 VOLTAGE SENSING RELAYS COMBINE A SOLID STATE SENSOR WITH A SPDT, 13 AMP OR DPDT 10 AMP RELAY. UL Recognized File No. E62636 PULL-IN & DROPOUT VOLTAGES ARE INDEPENDENTLY ADJUSTABLE. THE 236 CAN BE USED EITHER AS A OVER OR UNDER VOLTAGE DETECTING RELAY. STATUS L.E.D. INCLUDED. APPLICATIONS: BROWNOUT PROTECTION, WARNING OF UNDER VOLTAGE CONDITIONS AND OVER VOLTAGE PROTECTION. PREVENTS EQUIPMENT BURNOUT. OPTIONAL TIME DELAY AVAILABLE IN OCTAL PIN VERSION GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS VOLTAGE SENSING: Nominal Input: 24, 120, 240, 480 VAC 50/60Hz, 24 VDC. other AC & DC voltages available Adjustment Range: Pull-in 75% to 115% of nominal voltage, Dropout 75% to 95% of pickup setting Repeatability: ± 1% @ constant voltage & temperature CONTACTS Contact Material: Silver cadmium oxide Contact Rating: SPDT: 13 amps @ 240 VAC, 28 VDC Res. 1/3 Hp @ 120 VAC, 1/2 Hp @ 240 / 480 AC, 3 amps @ 480 VAC, NEMA B300 pilot duty DPDT: 10 amps @ 240 VAC / 28 VDC Res. 1/3Hp @ 120 VAC, 1/2 Hp 240 VAC. NEMA B300 pilot duty Electrical Life: 100,000 operations @ rated load Mechanical Life: SPDT: 5,000,000 operations DPDT: 10,000,000 operations INPUT Input Current: 15 mA (1.7 VA) @ 120 VAC 12 mA 240 VAC max. (2.9VA) 7 mA max. 480 AC (3.41 VA) Temperature Range Operate: - 30˚C to + 55˚C Temperature Range Storage: - 40˚C to + 85˚C DIELECTRIC STRENGTH Coil to Contacts: 2500 V rms Mating Sockets Across Open Contacts: 1000 V rms 70-750D8-1, 70-750D11-1, Transient: UL 508 surge 5000 V for 50 microseconds 70-464-1, 70-465-1: SCREW/DIN 70-169-1, 70-170-1: SCREW/PANEL Noise Immunity: NEMA ICS2-230, 2500 VAC. See section 8, page 7 - 12 70-463-1: SCREW/DIN MECHANICAL 70-124-1: SOLDER 70-178-1, 70-178-2: PRINTED CIRCUIT Enclosure: Polycarbonate dust cover 70-124-2: QUICK CONNECT Terminals: 0.187 quick connect terminals, or 8 pin octal base See section 8, page 16, 17 Power "ON" Indicator: L.E.D. ( green) Weight: 124.4 grams, 155.5 grams (8 pin octal) 4...25 PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com CLASS VOLTAGE SENSING RELAYS 236 SPDT, 13 AMPS & DPDT, 10 AMPS OUTLINE DIMENSIONS DIMENSIONS SHOWN IN INCHES & (MILLIMETERS). 2.93 1.75 (74.4) (44.4) 5 4 3 6 2.37 (60.35) FIGURE A 2 7 8 1 1.53 2.90 MAX. 0.312 WIRING DIAGRAM (38.8) (73.8) (7.9) 1 2 3 4 5 6 1.40 FIGURE B 5 (35.7) 4 7 8 9 3 6 A B 2 7 8 1 INPUT RECESSED SCREW ADJUSTMENTS 8 PIN OCTAL PULL-IN 1.50 (38.1) 1 2 DROPOUT 4 5 6 L.E.D 7 8 9 A B INPUT SQUARE BASE CONTINUOUS VOLTAGE MUST BE SUPPLIED TO INPUT. STANDARD VOLTAGE NOMINAL VOLTAGE PART FIG. DROP-OUT INPUT PULL-IN NUMBERS RANGE VOLTAGE RANGE 120 VAC W236ACPX-1 A 92 TO 140 VAC 24 VAC W236ACPX-4 A 20 TO 30 VAC 75% TO 95% OF 24 VDC W236CPX-2 A 20 TO 30 VDC PICKUP VOLTAGE 120 VAC W236ACX-1 B 90 TO 138 VAC SETTING 208 / 220 / 120 VAC W236ACX-2 B 180 TO 276 VAC 480 VAC W236ACX-3 B 360 TO 552 VAC CALL FACTORY FOR OTHER VOLTAGES, TIME AND FUNCTIONS 4...26 L.E.D Your Contact for Relays SECTION 4 CROSS REFERENCE GUIDE SECTION 4 MAGNECRAFT CUTLER CUTLER MAGNECRAFT SIEMENS SIEMENS SQUARE D SQUARE D NTE NTE POTTER & BRUMFIELD POTTER & BRUMFIELD & STRUTHERS-DUNN HAMMER HAMMER & STRUTHERS-DUNN CDB-38-70001 W211ACPSOX-18 RSSAN-10A CDB-38-70003/CGB-38-70010S/ W211ACPSOX-5 RSSAN-25A MTON1P120A OND-0110-120A 9050JCK11V20 CHB-38-70001/CKB-38-70010/ CB-1003B-70 RSSAN-40A W211ACPSOX-7 CKB-38-70180/CHB-38-70003/ RSSAN-50A MTON2P120A OND-1180-120A 9050JCK15V20 CB-1005B-70/CDB-38-70005 RSSAN-75A R28-11A10-120M W211ACPSOX-8 CGB-38-70005M - W211ACPSOX-60 CGB-38-70010M - 9050JCK16V20 W211ACPSOX-61 - 9050JCK17V20 W211ACPSOX-62 CGB-38-70050M RSSAN-50A 9050JCK18V20 W211ACPSOX-63 CB-1007B70 RSSAN-75A 9050JCK19V20 W211CPSOX-1 CHD-38-30001/CB-1028D-30/CDD-38-30003 RSSAN-90A OND-0110-24D W211ACPSRX-5 CHB-38-70011/CB-1021B-78 - MTOF1P120A OFD-0110-120A 9050JCK21V20 W211ACPSRX-7 CHB-38-70013 MTOF2P120A OFD-1180-120A 9050JCK25V20 W211CPSRX-1 CHD-38-30011 W211CPSRX-3 CHD-38-30013/CDD-38-30008 RSSDN-10A THE CROSS REFERENCE IS RSSDN-25A MAGNECRAFT MAGNECRAFT INTENDED TO MATCH FOOT PRINT, POTTER & BRUMFIELD POTTER & BRUMFIELD SQUARE D SQUARE D & STRUTHERS-DUNN & STRUTHERS-DUNN INTERNAL WIRING, AND CONTACT - LOAD RATINGS. TDRPRO-5000 CNM5, CNS-35-96, CNS-35-76 RSSDN-50A JCK60, JCK70 TDRPRO-5002 CN1, CNS-35-92, CNS-35-72 RSSDN-75A CONSTRUCTION FEATURES AND GENERAL SPECIFICATIONS MAGNECRAFT MAGNECRAFT RSSDN-10A POTTER & BRUMFIELD POTTER & BRUMFIELD SHOULD BE COMPARED IF EXACT & STRUTHERS-DUNN & STRUTHERS-DUNN RSSDN-25A REPLACEMENT IS REQUIRED. W67CPSOX-1 R123012X2E1 - W67CPSOX-2 R123024X2E1 RSSDN-50A MAGNECRAFT MAGNECRAFT RSSDN-75A SQUARE D SQUARE D & STRUTHERS-DUNN & STRUTHERS-DUNN RSSDN-90A W222ACPFX-11 9050JCK51V20 - W222ACPFX-27 9050JCK57V20 MAGNECRAFT MAGNECRAFT CUTLER CUTLER POTTER & BRUMFIELD POTTER & BRUMFIELD MIDTEX MIDTEX & STRUTHERS-DUNN & STRUTHERS-DUNN HAMMER HAMMER W388ACPSOX-1 CLF-41-70010 614-12T400 W388ACPSOX-2 W388CPSOX-1 CLH-41-30010 614-12C400 W388CPSOX-2 612-12C400 W388CPSRX-22 612-43T100 W388ACPSOX-42 MTON1B120A 614-43T400 W388ACPSOX-44 MTON2B120A 612-43C100 W388CPSRX-2 612-43C400 W388CPSRX-4 U. S. A. U. S. A. FOR TIME DELAY FOR TIME DELAY TELEPHONE: (843) 393-5778 APPLICATION APPLICATION FAX: (843) 393-4123 ENGINEERING ASSISTANCE ENGINEERING ASSISTANCE WEBSITE: www.magnecraft.com EMAIL: info@magnecraft.com Scott Heilman, PRODUCT MANAGER FAX: (843) 395-8530 EUROPE EUROPE EMAIL: sheilman@magnecraft.com TELEPHONE: 4989 / 75080310 FAX ON DEMAND: 1-800-891-2957 FAX: 4989 / 7559344 WEBSITE: www.magnecraft.com DOCUMENT: 500 EMAIL: renatesteinback@magnecraft.de 4...27

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the W222ACPFX-16 have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Magnecraft W199ADEX-4 Open Style Power Relay 120V 50/60Hz

product

Magnecraft W226R-7-5A1 Relay - 5 VDC; Solid State; 7 A (Max.); SPST-NO; 100 A; Panel Mount; DC...

product

Magnecraft W78CSX-3 Plug-in Relay - Electromechanical Relay, 4PDT 3A 24VDC 650Ohm Plug-In

product

Magnecraft W7PCX-7/MMS212 Relay; 2 A; 100 VAC; 12 VDC; PCB Subminiature; 500 V (RMS); PC Mount...

product

Magnecraft W92S11A22-120 Relay - W92 Combination DIN and Flange Mount Power Relay 120 VAC, 50/60 Hz,...

product

Magnecraft WM60AAA-120A Relay - Mercury Displacement, Up to 3PST, 60 Amp, AC and DC, 7 to 28VA 3 to ...