MAC VALVES 224 B 111 CA

Image of MAC VALVES 224 B 111 CA

Description

MAC Valves 224 B 111 CA Valve - 1/8” ports / conduit connector

Part Number

224 B 111 CA

Price

Request Quote

Manufacturer

MAC VALVES

Lead Time

Request Quote

Category

PRODUCTS - 2

Specifications

Coil

General purpose class A, continuous duty, encapsulated

Filtration

40 µ

Flow (at 6 bar, ?P-1bar)

0.5 Cv

Fluid

Compressed air, vacuum, inert gases

Lubrication

Not required, if used select a medium aniline point lubricant (between 180°F and 210°F)

Power

~ Inrush : 33 VA

Pressure range

Vacuum to 150 PSI

Protection

Consult factory

Temperature range

0°F to 140°F (-18°C to 60°C)

Voltage range

-15% to +10% of nominal voltage

Features

Datasheet

pdf file

Mac Valves-200 Series-Datasheet-337166453.pdf

866 KiB

Extracted Text

Direct solenoid and solenoid pilot operated valves Series 200 Individual mounting Series inline inline hazardous location 35 Manifold mounting sub-base sub-base sub-base with pressure hazardous non “plug-in” regulators location 100 200 200 Manual operator 55 56 57 Sealed solenoid enclosure 58 59 Armature 45 Solenoid push pin 700 Spring biased moveable pole piece 1 2 N.C. CYL Balanced poppet 900 3 N.O. 82 Valve spring 6300 SERIES FEATURES 6500 ® • The patented MACSOLENOID with its non-burn out feature on AC service. 6600 • Six valve functions with one Inline valve and four valve functions with one Manifold valve. • A triple rated coil for 120/60, 110/50 or 24 VDC (6 Watt). 1300 • Inline & add-a-unit manifold capability. • Use on lube or non-lube service. 800 • Extremely rapid response and cycle rate. • Various types of manual operators and electrical enclosures. ISO 1 • Extremely long service life. ISO 2 • Optional low wattage DC solenoids down to 1 watt. ISO 3 MAC 125A MAC 250A MAC 500A 31 Consult “Precautions” page 364 before use, installation or service of MAC Valves W WARRANTY ARRANTY 100% 100% 100% 100% OF OF PRODUCTION PRODUCTION TESTED TESTED 18 18 18 18 100% 100% 100% 100% MONTHS MONTHS Series 200 APPLICATION CONVERSION PROCEDURE: 3-ways and 2-ways. Changes within a stack from one function to another can be made without disturbing the plumbing. INDIVIDUAL MODELS SPECIAL APPLICATIONS: The balanced poppet design facilitates using the same valve for 6 functions with any port N.C. ONLY MODELS being connected to vacuum, pressure or plugged. Piping is shown in the chart below. A single purpose Normally Closed Only model is available for those applications where a greater tolerance for heavy concentrations of water, compressor products and other air MANIFOLD MODELS line contaminants is desired. The interchangeable function plate between the valve body and base permits selection for 2- or 3-way, Normally Closed or Normally Open operation, instead of through piping EXPLOSION PROOF MODELS as shown below in the Inlines. On 3-way applications, one function plate is used for both These models are designed to meet U.L. and C.S.A. standards for Division 1, Class I, N.C. and N.O. When "3-C" is visible on the plate, the function will be N.C. Groups B, C, D and Class II, Groups E, F and G (NEMA equivalent to Class I is NEMA 7; When "3-O" is visible, the function is N.O. On 2-way applications, a separate plate is used Class II is NEMA 9). Explosion proof models are available in either inline or manifold and like the 3-way plate is marked "2-C" for N.C. and "2-O" on the other side for N.O. versions but only with the no operator ("O") manual operator. The 2-way plates block the exhaust at the valve, permitting the mixing in a stack of PIPING CHART FOR INDIVIDUAL MODELS 21 21 21 X 3 3 3 PLUGGED 3 Way 2 Way Selector Normally Closed Normally Closed P L 21 21 U 21 X G G E D 3 3 3 3 Way 2 Way Divertor Normally Open Normally Open Supply Operator De-Energized Operator Energized 32 32 Consult “Precautions” page 364 before use, installation or ser Consult “Precautions” page 364 before use, installation or service of MAC V vice of MAC Valves alves Direct solenoid and solenoid pilot operated valves Series 200 Function Port size Flow (Max) Individual mounting Series 3/2 NO-NC, 2/2 NO-NC 1/8” - 1/4” 0.5 C inline v OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of 35 pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 100 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. 200 200 55 56 HOW TO ORDER 57 58 Port size Universal valve NC only valve 59 2 2 13 13 1/8” NPTF 224B-XXYZZ 274B-XXYZZ 1/4” NPTF 225B-XXYZZ 275B-XXYZZ 45 * ³ SOLENOID OPERATOR XX Y ZZ XX Voltage Y Manual operator ZZ Electrical connection 700 11 120/60, 110/50, 24 VDC (6.0 W) 1 Non-locking JA Square connector 12 240/60, 220/50 2 Locking JC Square connector with light 22 24/60, 24/50 BA Flying leads (18”) 900 52 24 VDC (2.5 W) CA Conduit 1/2” NPS 78 24 VDC (24.0 W) 61 24 VDC (8.5 W) 82 * Other options available, see page 357. Notes: CHANGING FROM NORMALLY CLOSED TO NORMALLY OPEN 6300 Individual inline valves can be changed from normally closed to normally open by connecting the inlet to port 3 instead of port 1. NORMALLY CLOSED ONLY MODELS 6500 A single purpose Normally Closed only model is available for those applications where a greater tolerance for heavy concentrations of water, compressor products and other air line contaminants is desired. Model numbers are indicated above. 6600 1300 800 ISO 1 ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A 33 Consult “Precautions” page 364 before use, installation or service of MAC Valves GARANTIE 100% 100% D E L A P R O D U C T I O N T E S T É E 18 18 100% 100% M O I S WARRANTY 100% 100% O F P R O D U C T I O N T E S T E D 18 18 100% 100% M O N T H S Series 200 technical data Fluid : Compressed air, vacuum, inert gases Pressure range : Vacuum to 150 PSI Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Filtration : 40 µ temperature range : 0°F to 140°F (-18°C to 60°C) Flow (at 6 bar, ∆P=1bar) : 0.5 C v Leak rate : Coil : General purpose class A, continuous duty, encapsulated Voltage range : -15% to +10% of nominal voltage Protection : Consult factory Power : ∼ Inrush : 33 VA Holding : 19.7 VA = 1 to 24 W response times : 24 VDC (8.5 W) Energize : 15 ms De-energize : 5 ms 120/60 Energize : 3-8 ms De-energize : 3-13 ms Spare parts : •-Solenoid operator (power ≥ 6 W) : D4-XXAAB, cover mounting screws 32222 and seal B5-6001. Options : • BSPP threads. Dimensions shown are metric (mm) dimensions 99.2 5.1 DIA.-THRU TYP.(2) 3 27.83 2 1 TYP.(2) 38.6 TYP. (2) 34.6 5.29 88.6 45.2 34 Consult “Precautions” page 364 before use, installation or service of MAC Valves Direct solenoid and solenoid pilot operated valves Series 200 Function Port size Flow (Max) Individual mounting Series inline 3/2 NO-NC, 2/2 NO-NC 1/8” - 1/4” 0.5 C hazardous v location OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of 35 pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 100 4. Powerful return spring. 5. Burn-out proof solenoid on AC service. 200 200 55 56 HOW TO ORDER 57 58 Port size Universal valve NC only valve 59 2 2 13 13 1/8” NPTF 224B-XX0EA 274B-XX0EA 1/4” NPTF 225B-XX0EA 275B-XX0EA 45 ³ SOLENOID OPERA TOR XX XX Voltage 700 11 120/60, 110/50, 24 VDC (6.0 W) 12 240/60, 220/50 22 24/60, 24/50 900 50 24 VDC (6.0 W) 55 12 VDC (6.0 W) 60 12 VDC (9.5 W) 61 24 VDC (8.5 W) 82 Notes: The special version of the 200 Series designed for hazardous locations has been approved by CSA for Class I, Groups B, C & D; Class II, Groups E, F & G. Maximum rated fluid and ambient temperature is 40°C; maximum pressure is 150 p.s.i. 6300 Approval is limited to certain common AC & DC voltages which are those designated in the table above. 6500 These valves are supplied without manual operators. This version of the 200 Series can be supplied on the standard individual inline or the manifold valve body assemblies. It can also be supplied as a pilot for the 57, 58 and 59 Series (with special adapter plate # M-00012). 6600 CHANGING FROM NORMALLY CLOSED TO NORMALLY OPEN Individual inline valves can be changed from normally closed to normally open by connecting the inlet to port 3 instead of port 1. 1300 NORMALLY CLOSED ONLY MODELS A single purpose Normally Closed only model is available for those applications where a greater tolerance for heavy concentrations of water, compressor products and other air line contaminants is desired. Model numbers are indicated above. 800 ISO 1 ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A 35 Consult “Precautions” page 364 before use, installation or service of MAC Valves GARANTIE 100% 100% D E L A P R O D U C T I O N T E S T É E 18 18 100% 100% M O I S WARRANTY 100% 100% O F P R O D U C T I O N T E S T E D 18 18 100% 100% M O N T H S Series 200 technical data Fluid : Compressed air, vacuum, inert gases Pressure range : Vacuum to 150 PSI Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Filtration : 40 µ temperature range : 0°F to 104°F (-18°C to 40°C) Leak rate : 1 Coil : General purpose class A, continuous duty, encapsulated Voltage range : -15% to +10% of nominal voltage Protection : NEMA 7, NEMA 9; Class I Groups B, C & D; Class II Groups E, F & G. Power : ∼ Inrush : 33 VA Holding : 19.7 VA = 1 to 24 W response times : 24 VDC (8.5 W) Energize : 15 ms De-energize : 5 ms 120/60 Energize : 3-8 ms De-energize : 3-13 ms Spare parts : •-Solenoid operator (power ≥ 6 W) : D4-XXAAB. • Adapter plate ass’y. : A3-0506. Options : • BSPP threads. Dimensions shown are metric (mm) dimensions 14.2 1/2" NPSM CONDUIT 17.6 ADAPTER PLATE 138.8 5.1 DIA. 2 MTG HOLES 17.4 27.8 57.9 22.9 11.1 38.7 34.6 50.8 36 Consult “Precautions” page 364 before use, installation or service of MAC Valves Direct solenoid and solenoid pilot operated valves Series 200 Function Port size Flow (Max) Manifold mounting Series sub-base 3/2 NO-NC, 2/2 NO-NC 1/8” - 1/4” 0.5 C v non “plug-in” OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of 35 pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 100 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. 200 200 55 56 HOW TO ORDER 57 58 Port size Universal valve NC only valve 59 CYL CYL IN EXH IN EXH Valve less base 250B-XXYZZ 280B-XXYZZ 1/8” base NPTF 256B-XXYZZ 286B-XXYZZ 45 1/4” base NPTF 257B-XXYZZ 287B-XXYZZ * SOLENOID OPERATOR ³ XX Y ZZ 700 XX Voltage Y Manual operator ZZ Electrical connection 11 120/60, 110/50, 24 VDC (6.0 W) 1 Non-locking JC Square connector with light 12 240/60, 220/50 2 Locking JA Square connector 900 22 24/60, 24/50 BA Flying leads (18”) 52 24 VDC (2.5 W) CA Conduit 1/2” NPS 78 24 VDC (24.0 W) 61 24 VDC (8.5 W) 82 * Other options available, see page 357. 6300 End plate kit required (Port size : 1/4”) : A2-5003-01. OPTIONS 6500 207 26XB-XXYZZ 206 6600 (Base only - 1/4”) - universal 2-way (Base only - 1/8”) 1300 800 CHANGING FROM NORMALLY CLOSED TO NORMALLY OPEN For manifold base mounted valves a plate is provided between the valve and the base. Three plates are available; a reversible plate for 3 Way valves (N.C. & N.O.), one plate for 2 Way N.C. and one for 2 Way N.O. Appropriate plates, determined by the valve model number, are ISO 1 supplied automatically with the valve. ISO 2 NORMALLY CLOSED ONLY MODELS A single purpose Normally Closed only model is available for those applications where a greater tolerance for heavy concentrations of water, ISO 3 compressor products and other air line contaminants is desired. Model numbers are indicated above. MAC 125A MAC 250A MAC 500A 37 Consult “Precautions” page 364 before use, installation or service of MAC Valves GARANTIE 100% 100% D E L A P R O D U C T I O N T E S T É E 18 18 100% 100% M O I S WARRANTY 100% 100% O F P R O D U C T I O N T E S T E D 18 18 100% 100% M O N T H S Series 200 technical data Fluid : Compressed air, vacuum, inert gases Pressure range : Vacuum to 150 PSI Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Filtration : 40 µ temperature range : 0°F to 140°F (-18°C to 60°C) Flow (at 6 bar, ∆P=1bar) : 0.5 C v 3 Leak rate : 100 cm /min Coil : General purpose class A, continuous duty, encapsulated Voltage range : -15% to +10% of nominal voltage Protection : Consult factory Power : ∼ Inrush : 33 VA Holding : 19.7 VA = 1 to 24 W response times : 24 VDC (8.5 W) Energize : 15 ms De-energize : 5 ms 120/60 Energize : 3-8 ms De-energize : 3-13 ms Spare parts : •-Solenoid operator (power ≥ 6 W) : D4-XXAAB, cover mounting screws 32222 and seal B5-6001. • Function plate : A2-7005. • Seal between bases : B5-5010. • Tie-rod (x2) : B4-9004. Options : • BSPP threads. • Explosion-proof model. • Isolation of inlet : Mod. 313P. • Isolation of exhaust : Mod. 313E. • Additional bottom inlet : Mod. 0210. • Bottom cyl. port : Mod. 0009. • All bottom & side ports : Mod. 0004. Note : • Specify Mod. number after valve model number (i.e. 257B-111BA Mod. 0210) Dimensions shown are metric (mm) dimensions 1/8” OR 1/4” CYL PORT OPTIONAL 1/8” OR 1/4” BOTTOM PORTS 1/4” INLET & EXH. PORTS EACH END MT’G SLOT 8,1 DIA. MAX. 38 Consult “Precautions” page 364 before use, installation or service of MAC Valves Direct solenoid and solenoid pilot operated valves Series 200 Function Port size Flow (Max) Manifold mounting Series sub-base 3/2 NO-NC, 2/2 NO-NC 1/4” 0.4 C with pressure v regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of 35 pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 100 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. 7. Individual pressure control to each cylinder 200 200 port. 55 56 HOW TO ORDER 57 Port size Universal valve NC only valve 58 59 CYL CYL IN EXH IN EXH Valve less base 250B-XXYZZ 280B-XXYZZ 1/4” base NPTF 252B-XXYZZ 282B-XXYZZ 45 * ³ SOLENOID OPERATOR XX Y ZZ XX Voltage Y Manual operator ZZ Electrical connection 700 11 120/60, 110/50, 24 VDC (6.0 W) 1 Non-locking JA Square connector 12 240/60, 220/50 2 Locking JC Square connector with light 22 24/60, 24/50 BA Flying leads (18”) 900 52 24 VDC (2.5 W) CA Conduit 1/2” NPS 78 24 VDC (24.0 W) 61 24 VDC (8.5 W) 82 * Other options available, see page 357. Manifold fastening kit required : N-02003 6300 MODEL INDIVIDUAL PRESSURE CONTROL TO EACH CYLINDER PORT 252B- In this version the common inlet pressure supplies each individual valve in the stack. This common pressure passes 6500 3-Way N.C. or N.O. through a relieving type regulator mounted on the same base as the valve and is supplied through the function 262B- plate to the Normally Closed or Normally Open poppet position. Through use of the appropriate function plate on 2-Way N.C. or N.O. the 200 Series basic valve, the operation can be Normally Closed Or Normally Open, 3-way or 2-way except for 6600 282B- 282B models which are Normally Closed only. The exhaust ("out") port is common. Operation of the valves then 3-Way N.C. only opens or closes the cylinder port (See schematic diagram next page). 1300 800 ISO 1 ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A 39 Consult “Precautions” page 364 before use, installation or service of MAC Valves GARANTIE 100% 100% D E L A P R O D U C T I O N T E S T É E 18 18 100% 100% M O I S WARRANTY 100% 100% O F P R O D U C T I O N T E S T E D 18 18 100% 100% M O N T H S Series 200 technical data Fluid : Compressed air, vacuum, inert gases Pressure range : Vacuum to 150 PSI Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Filtration : 40 µ temperature range : 0°F to 140°F (-18°C to 60°C) Flow (at 6 bar, ∆P=1bar) : 0.4 C v 3 Leak rate : 100 cm /min Coil : General purpose class A, continuous duty, encapsulated Voltage range : -15% to +10% of nominal voltage Protection : Consult factory Power : ∼ Inrush : 33 VA Holding : 19.7 VA = 1 to 24 W response times : 24 VDC (8.5 W ) Energize : 15 ms De-energize : 5 ms 120/60 Energize : 3-8 ms De-energize : 3-13 ms Spare parts : •-Solenoid operator (power ≥ 6 W) : D4-XXAAB, cover mounting screws 32222 and seal B5-6001. • Function plate : A2-7005. • Seal between bases (x2) : 17016-01. • Tie-rod (x2) : B4-9004. • Pressure regulator : PR02A-A0AA. Options : • BSPP threads. • Explosion-proof model. • Isolation of inlet and/or exhaust. • Mod. PR80 (0-80 pressure range), Mod PR30 (0-30 pressure range) Dimensions shown are metric (mm) dimensions 128.9 1/2" NPS CONDUIT 110.5 5.7 DIA. 1/8" NPTF MTG GAUGE PORT HOLE 148.2 EXH IN 21.5 17.5 13.5 CYL. CYL. 1/4" NPTF 7.5 19.0 20.5 15.0 1/4" NPTF 51.5 46.0 IN & EXH. PORTS 65.0 BOTH ENDS CYL. CYL. CYL. EXHAUST ("OUT") ("OUT") INLET ("IN") ("IN") SCHEMATIC 3-VALVE STACK 40 Consult “Precautions” page 364 before use, installation or service of MAC Valves SOL SOL SOL Direct solenoid and solenoid pilot operated valves Series 200 Function Inlet & outlet port size Flow (Max) Manifold mounting Series sub-base 3/2 NO-NC, 2/2 NO-NC 1/4” 0.4 C with pressure v regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of 35 pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 100 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. 7. Selected pressure control to a single outlet. 200 200 55 56 HOW TO ORDER 57 58 Port size NC only valve 59 CYL IN EXH Valve 251B-XXYZZ 45 * ³ SOLENOID OPERATOR XX Y ZZ XX Voltage Y Manual operator ZZ Electrical connection 11 120/60, 110/50, 24 VDC (6.0 W) 1 Non-locking JA Square connector 700 12 240/60, 220/50 2 Locking JC Square connector with light 22 24/60, 24/50 BA Flying leads (18”) 52 24 VDC (2.5 W) CA Conduit 1/2” NPS 78 24 VDC (24.0 W) 900 61 24 VDC (8.5 W) * Other options available, see page 357. 82 Manifold fastening kit required : N-02003 MODEL SELECTED PRESSURE CONTROL TO A SINGLE OUTLET 6300 251B- This version permits the alternate selection of any of the regulated pressures in the stack to one common outlet. With 3-Way Normally Closed all valves de-energized the regulated pressure supplied to the Normally Open pressure port passes through the valves and out the corresponding port at the other end of the stack (Common Outlet Port). Pressure supplied to the 6500 common inlet port is regulated at each valve and blocked by the poppet of each valve. When a valve is shifted in the stack the Normally Open pressure is blocked and the regulated normally closed pressure of that valve is open to 6600 the common outlet. If two valves are energized at the same time the pressure at the common outlet would be that of the energized valve nearest the outlet. If the normally open pressure port is not used it is open to exhaust from the common outlet. The individual cylinder port in each base is non-operative. (See schematic diagram next page). 1300 800 ISO 1 ISO 2 ISO 3 MAC 125A MAC 250A MAC 500A 41 Consult “Precautions” page 364 before use, installation or service of MAC Valves GARANTIE 100% 100% D E L A P R O D U C T I O N T E S T É E 18 18 100% 100% M O I S WARRANTY 100% 100% O F P R O D U C T I O N T E S T E D 18 18 100% 100% M O N T H S Series 200 technical data Fluid : Compressed air, vacuum, inert gases Pressure range : Vacuum to 150 PSI Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Filtration : 40 µ temperature range : 0°F to 140°F (-18°C to 60°C) Flow (at 6 bar, ∆P=1bar) : 0.4 C v 3 Leak rate : 100 cm /min Coil : General purpose class A, continuous duty, encapsulated Voltage range : -15% to +10% of nominal voltage Protection : Consult factory Power : ∼ Inrush : 33 VA Holding : 19.7 VA = 1 to 24 W response times : 24 VDC (8.5 W ) Energize : 15 ms De-energize : 5 ms 120/60 Energize : 3-8 ms De-energize : 3-13 ms Spare parts : •-Solenoid operator (power ≥ 6 W) : D4-XXAAB, cover mounting screws 32222 and seal B5-6001. • Function plate : A2-7005. • Seal between bases (x2) : 17016-01. • Tie-rod (x2) : B4-9004. • Pressure regulator : PR02A-A0AA. Options : • BSPP threads. • Explosion-proof model. • Isolation of inlet and/or exhaust. • Mod. PR80 (0-80 pressure range), Mod PR30 (0-30 pressure range) Dimensions shown are metric (mm) ddiim me en ns siio on nss 128.9 1/2" NPS CONDUIT 110.5 5.7 DIA. 1/8" NPTF MTG GAUGE PORT HOLE 148.2 EXH IN 17.5 13.5 19.0 1/4" NPTF 46.0 20.5 IN & EXH. PORTS 51.5 BOTH ENDS 65.0 EXHAUST OR COMMON OUTLET N.O. OPTIONAL ("OUT") PRESSURE ("OUT") COMMON SUPPLY ("IN") SCHEMATIC ("IN") 3-VALVE STACK 42 Consult “Precautions” page 364 before use, installation or service of MAC Valves SOL SOL SOL Direct solenoid and solenoid pilot operated valves Series 200 Function Port size Flow (Max) Manifold mounting Series sub-base 3/2 NO-NC, 2/2 NO-NC 1/8” - 1/4” 0.5 C hazardous v location OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of 35 pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 100 4. Powerful return spring. 5. Burn-out proof solenoid on AC service. 200 200 55 56 HOW TO ORDER 57 Port size Universal valve NC only valve 58 59 CYL CYL IN EXH IN EXH Valve less base 250B-XX0EA 280B-XX0EA 1/8” base NPTF 258B-XX0EA 288B-XX0EA 45 1/4” base NPTF 259B-XX0EA 289B-XX0EA SOLENOID OPERA TOR ³ XX 700 XX Voltage 11 120/60, 110/50, 24 VDC (6.0 W) 12 240/60, 220/50 900 22 24/60, 24/50 50 24 VDC (6.0 W) 55 12 VDC (6.0 W) 60 12 VDC (9.5 W) 82 61 24 VDC (8.5 W) End plate kit required (Port size : 1/4”) : A2-5003-01. 6300 OPTIONS 6500 26XB-XX0EA 208 209 - universal 2-way (Base only - 1/8”) (Base only - 1/4”) 6600 Notes: The special version of the 200 Series designed for hazardous locations has been approved by CSA for Class I, Groups B, C & D; Class II, Groups E, F & G. 1300 Maximum rated fluid and ambient temperature is 40°C; maximum pressure is 150 p.s.i. Approval is limited to certain common AC & DC voltages which are those designated in the table above. These valves are supplied without manual operators. This version of the 200 Series can be supplied on the standard individual inline or the manifold valve body 800 assemblies. It can also be supplied as a pilot for the 57, 58 and 59 Series (with special adapter plate # M-00012). ISO 1 CHANGING FROM NORMALLY CLOSED TO NORMALLY OPEN For manifold base mounted valves a plate is provided between the valve and the base. Three plates are available; a reversible plate for 3 Way valves (N.C. & ISO 2 N.O.), one plate for 2 Way N.C and one for 2 Way N.O. Appropriate plates, determined by the valve model number, are supplied automatically with the valve. NORMALLY CLOSED ONLY MODELS ISO 3 A single purpose Normally Closed only model is available for those applications where a greater tolerance for heavy concentrations of water, compressor MAC 125A products and other air line contaminants is desired. Model numbers are indicated above. MAC 250A MAC 500A 43 Consult “Precautions” page 364 before use, installation or service of MAC Valves GARANTIE 100% 100% D E L A P R O D U C T I O N T E S T É E 18 18 100% 100% M O I S WARRANTY 100% 100% O F P R O D U C T I O N T E S T E D 18 18 100% 100% M O N T H S Series 200 technical data Fluid : Compressed air, vacuum, inert gases Pressure range : Vacuum to 150 PSI Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Filtration : 40 µ temperature range : 0°F to 140°F (-18°C to 60°C) Flow (at 6 bar, ∆P=1bar) : 0.5 C v 3 Leak rate : 100 cm /min Coil : General purpose class A, continuous duty, encapsulated Voltage range : -15% to +10% of nominal voltage Protection : Consult factory Power : ∼ Inrush : 33 VA Holding : 19.7 VA = 1 to 24 W response times : 24 VDC (8.5 W ) Energize : 15 ms De-energize : 5 ms 120/60 Energize : 3-8 ms De-energize : 3-13 ms Spare parts : •-Solenoid operator (power ≥ 6 W) : D4-XXAAC-0EA. • Function plate : A2-7005. • Seal between bases : B5-5010. • Tie-rod (x2) : 19598. Options : • BSPP threads. • Isolation of inlet : Mod. 313P. • Isolation of exhaust : Mod. 313E. • Additional bottom inlet : Mod 0210. Dimensions shown are metric (mm) dimensions R4.0 TYP. (2) 127.8 122.9 118.0 35.6 TYP. (2) 142.7 94.5 52.9 72.8 92.7 20.1 TYP. (2) 1/4" NPTF 44 Consult “Precautions” page 364 before use, installation or service of MAC Valves O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length ³ VALVE CODE - XX Y ZZ (-VV) 1 2 3 4 OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - valves type 200 Series - pilot valves "CNOMO" - Pilot operated valves with pilots type 100 Series - pilot operated valves with pilots type 200 Series Series : 55 - 56 - 700 - 800 - 900 Series : 200 - 57 - 58 - 59. - 6300 - 6500 - 6600 - 1300 - ISO 1 - ISO 2 - ISO 3. - MAC 125 - MAC 250 - MAC 500 - Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3 357 Consult “Precautions” page 364 before use, installation or service of MAC Valves OPTIONS Used on valve series: 100, 55, 56, 700, 800, 900, 6300, 6500, 6600, 1300, MVA1C, Used on valve series: 200, 57, 58, 59. MVA2B, MVA3B, MAC125, MAC250, MAC500. 1. VOLTAGE (100 Serie type coil) 1. VOLTAGE (200 Serie type coil) - XX Y ZZ VOLTAGE - XX Y ZZ VOLTAGE 11 120/60, 110/50 11 120/60, 110/50, 24 VDC (6 W) 12 240/60, 220/50 12 240/60, 220/50 13 100/60, 100/50 13 100/60, 100/50 15 200/60, 200 /50 14 200/60, 200/50 16 10/60 20 6/60 20 6/60 21 12/60 21 12/50, 12/60 22 24/60, 24/50 22 24/60, 24/50 23 32/60, 32/50 23 32/60, 32/50 24 48/60, 42/50 24 48/60, 42/50 25 240/50 26* 380/50, 440/50, 440/60, 480/60 26 480/60, 440/50 29 220/60 27 127/60 34 127/50, 120/50 28 415/50 35 48/50 29 220/60 36 16/60 30 380/50 B1 24/50 31 550/60, 550/50 50 24 VDC (6 W) 32 120/60, 110/50 51 24 VDC (4 W) 33 600/60 54 12 VDC (4 W) 34 127/50 55 12 VDC (6 W) 35 48/50 57 12 VDC (2.5 W) 50 24 VDC (6 W) 59 24 VDC (2.5 W) 51 24 VDC (4.5 W) 60 12 VDC (8.5 W) 52 24 VDC (2.5 W) 61 24 VDC (8.5 W) 53 24 VDC (1.0 W) 64 6 VDC (6 W) 55 12 VDC (6 W) 65 32 VDC (7 W) 57 12 VDC (2.5 W) 66 48 VDC (5.8 W) 58 48 VDC (2.5 W) 67 64 VDC (7.5 W) 60 12 VDC (9.5 W) 68 120 VDC (6.4 W) 61 24 VDC (8.5 W) 69* 220 VDC (8.7 W), 250 VDC (11.2 W) 64 6 VDC (8.5 W) 75 90 VDC (8.8 W) 65 32 VDC (10 W) 76* 100 VDC (6.9 W) 66 48 VDC (11.5 W) 84* 125 VDC (10.9 W) 67 64 VDC (10.5 W) 87* 24 VDC (17.1 W) 68 120 VDC (12.3 W) 88* 12 VDC (17.4 W) 69 250 VDC (9.2 W) 89* 36 VDC (18.8 W) 71 8 VDC (8.2 W) 90 28 VDC (8.2 W) 72 24 VDC (12 W) 91* 6 VDC (10.6 W) 73 198 VDC (10 W) 92 190 VDC (6.5 W) 74 72 VDC (11.3 W) 94 3 VDC (7 W) 75 90 VDC (11.3 W) 95 38 VDC (6.4 W) 76 100 VDC (9 W) A1 24 VDC (1 W) 77 220 VDC (10 W), 230 VDC (11.6 W) A2 12 VDC (1 W) 78* 24 VDC (24 W) A3 9 VDC (1 W) 80 55 VDC (10.6 W) MOD. DD01 : Protection diode (DC) - MAX. 8.5W 82 170 VDC (11.1 W) MOD. MOV1 : Protection varistor (AC) - MAX. 8.5W 83 15 VDC (8.1 W) * Voltages are CLSF only 84 125 VDC (10 W) 86 36 VDC (11 W) 93* 12 VDC (24 W) 358 Consult “Precautions” page 364 before use, installation or service of MAC Valves O p t i o n s OPTIONS 2. MANUAL OPERATOR (Common options for 100 & 200 Series type coils) - XX Y ZZ MANUAL OPERATOR 0 No operator 5* No Operator with Light 1 Non-locking recessed 6* Non-Locking Recessed with Light 2 Locking recessed 7* Locking Recessed with Light 3 Non-locking extended 8* Non-Locking Extended with Light 4 Locking extended 9* Locking Extended with Light * Lights used with “AA” electrical connection 3. ELECTRICAL CONNECTION (100 Serie type coil) 3. ELECTRICAL CONNECTION (200 Serie type coil) - XX Y ZZ ELECTRICAL CONNECTION - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit AA Wiring box with 1/2" NPS conduit BA Flying leads BA Flying leads CA 1/2" NPS conduit CA 1/2" NPS conduit CC 1/2" NPT conduit CC 1/2" NPT conduit FA Military type 2 PIN EA Explosion proof (200 Series) GA Military type 3 PIN EA Explosion proof (57, 58 & 59 Series) HA AA with ground wire FA Military type 2 PIN JA* Square connector GA Military type 3 PIN JB Rectangular connector HA AA with ground wire JC* Square connector with light JA* Square connector JD Rectangular connector with light JC Square connector with light JE Square connector on top JJ Square connector, male only (ISO2, ISO3) NA CA with ground wire JF Rectangular connector on top NC CC with ground wire (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit (100 Series-Manifold/900 Series) MB Electrical common conduit (100 Series-Stacking/700 Series) NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit * Not to be used with 100, 800 and 900 Series manifold mounting 359 Consult “Precautions” page 364 before use, installation or service of MAC Valves OPTIONS 4. COIL WIRE LENGTH (Common options for 100 & 200 Serie type coils) - XX Y ZZ (-VV) WIRE LENGTH AA 18” AB 24” AD 36” AE 48” AF 72” AG 6” AR 12” AU 120” BA 60” BB 144” Series 6000 : wire length, from the base MOD L024 24” MOD L036 36” MOD L048 48” MOD L060 60” MOD L072 72” MOD L120 120” 360 Consult “Precautions” page 364 before use, installation or service of MAC Valves

Frequently asked questions

What makes Elite.Parts unique?

chervon down
At GID Industrial (Elite.Parts' parent company), we specialize in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. There are other companies who claim to do what we do, but we're confident that our commitment to quality and value is unparalleled in our field.

What kind of warranty will the 224 B 111 CA have?

chervon down
Warranties differ by part and by which suppliers we use to procure it for you. Sometimes, a part will be sold as-is and without a warranty. Our specialty, single board computers, tend to receive a one-year warranty.

Which carriers does Elite.Parts work with?

chervon down
Elite.Parts can ship via FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. However, we can use other carriers if it will be more convenient for you.

Will Elite.Parts sell to me even though I live outside the USA?

chervon down
Absolutely! We are happy to serve customers regardless of location. We work with international clients all the time, and we are familiar with shipping to destinations all across the globe.

I have a preferred payment method. Will Elite.Parts accept it?

chervon down
All major credit cards are accepted: Visa, MasterCard, Discover, and American Express. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may available for larger orders, upon approval.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

Mac Valves 200 Series Solenoid Operator Valves | 3/2 N.O. - N.C. | 2/2 N.O. - N.C. Function | G1/8" ...

product

Mac Valve 224 B 111 BAAA Complete valve 120/60 volts

product

Mac Valves 225B111CA Valve - VALVE; SOLENOID VALVE 110/120VAC 24VDC 15W 1/2IN NPS

product

Mac valves 225B-111JA solenoid valve 24VDC 3 wore 1/4IN 120/110VAC 150PSI

product

MAC Valve 250B-111BAAA Solenoid Valve

product

Mac Valves 250B-111CAAA - 150PSI Valve